Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SONO 336 LABORATORIO / Profa. A.

Zayas 2017

Patient I.D. Sonographer


Tashnee M. Soler Francismarie
Martinez
Scan Quality

Clinical history
No utiliza medicamentos, no cirugas, ningn tipo de enfermedad.
Paciente siente molestia al tragar.
Dibuje aqui, donde se localiza la placa o estenosis
RIGHT
RIGHT P.S.V cm/s E.D.V cm/s Spect. Broad. % Stenosis
CCA 134.5 cm/s 23.2 cm/s N/A 0
ICA Prox 89.1 cm/s 26.7 cm/s N/A 0
ICA Dist 92.7 cm/s 22.3 cm/s N/A 0
ECA 73.9 cm/s 8.9 cm/s N/A 0
vertebral 49.8 cm/s 17.8 cm/s Antegrade Retrograde

TECHNICAL QUALITY PLAQUE


Excellent Homogenous
Good Mixed
Satisfactory Calcification
Poor Indeterminate
CAROTID DOPPLER

SURFACE TORTUOSITY BIFURCATION


Smooth Minimal High
Rough Moderate Normal
Maximum Low
Comments

_________________________________________________________________________________________________________
LEFT
LEFT P.S.V cm/s E.D.V cm/s Spect. Broad. % Stenosis
CCA 123.8 cm/s 20.5 cm/s N/A 0
ICA Prox 84.76 cm/s 18.16 cm/s N/A 0
ICA Dist 79.86 cm/s 19.96 cm/s N/A 0
ECA 95.96 cm/s 8.56 cm/s N/A 0
vertebral 58.1 cm/s 22.8 cm/s Antegrade Retrograde

TECHNICAL QUALITY PLAQUE


Excellent Homogenous
Good Mixed
Satisfactory Calcification
Poor Indeterminate

SURFACE TORTUOSITY BIFURCATION


Smooth Minimal High
Rough Moderate Normal
Maximum Low
Comments

Doppler Criteria for Diagnosis of ICA Stenosis


Degree of Stenosis (%) ICA PSV (cm/sec) EDV (cm/sec) PSV Ratio
<50 <125
50 - 69 125 - 230 with visible plaque
>70 >230 <140 >4.0
Near Occlusion >230 >140
Occluded No flow No flow

You might also like