MAXsa 10 CONTROLLER
For use with machines having Code Numbers:
11590, 11777, 12327
Date Purchased
SPECIAL SITUATIONS
DO NOT WELD OR CUT containers or materials which previously had
been in contact with hazardous substances unless they are properly
cleaned. This is extremely dangerous.
DO NOT WELD OR CUT painted or plated parts unless special
precautions with ventilation have been taken. They can release highly
toxic fumes or gases.
Additional precautionary measures
PROTECT compressed gas cylinders from excessive heat, mechanical
shocks, and arcs; fasten cylinders so they cannot fall.
BE SURE cylinders are never grounded or part of an electrical circuit.
REMOVE all potential fire hazards from welding area.
ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FOR
IMMEDIATE USE AND KNOW HOW TO USE IT.
SAFETY
2.b. EMF fields may interfere with some pacemakers, and welders
having a pacemaker should consult their physician before
FOR ENGINE POWERED welding.
EQUIPMENT. 2.c. Exposure to EMF fields in welding may have other health effects
which are now not known.
1.a. Turn the engine off before troubleshooting
and maintenance work unless the 2.d. All welders should use the following procedures in order to
maintenance work requires it to be running. minimize exposure to EMF fields from the welding circuit:
2.d.1. Route the electrode and work cables together - Secure
1.b. Operate engines in open, well-ventilated areas or vent the engine
them with tape when possible.
exhaust fumes outdoors.
2.d.2. Never coil the electrode lead around your body.
1.c. Do not add the fuel near an open flame 2.d.3. Do not place your body between the electrode and work
welding arc or when the engine is running. cables. If the electrode cable is on your right side, the
Stop the engine and allow it to cool before work cable should also be on your right side.
refueling to prevent spilled fuel from
2.d.4. Connect the work cable to the workpiece as close as pos-
vaporizing on contact with hot engine parts
sible to the area being welded.
and igniting. Do not spill fuel when filling tank. If fuel is spilled,
wipe it up and do not start engine until fumes have been 2.d.5. Do not work next to welding power source.
eliminated.
3
SAFETY
3.b. Insulate yourself from work and ground using dry insulation. 4.b. Use suitable clothing made from durable flame-resistant material
Make certain the insulation is large enough to cover your full area to protect your skin and that of your helpers from the arc rays.
of physical contact with work and ground.
4.c. Protect other nearby personnel with suitable, non-flammable
In addition to the normal safety precautions, if screening and/or warn them not to watch the arc nor expose
welding must be performed under electrically themselves to the arc rays or to hot spatter or metal.
hazardous conditions (in damp locations or while
wearing wet clothing; on metal structures such as FUMES AND GASES
floors, gratings or scaffolds; when in cramped
positions such as sitting, kneeling or lying, if there
CAN BE DANGEROUS.
is a high risk of unavoidable or accidental contact 5.a. Welding may produce fumes and gases
with the workpiece or ground) use the following hazardous to health. Avoid breathing these fumes and gases.
equipment: When welding, keep your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep fumes and gases
Semiautomatic DC Constant Voltage (Wire) Welder.
away from the breathing zone. When welding with
DC Manual (Stick) Welder.
electrodes which require special ventilation such
AC Welder with Reduced Voltage Control.
as stainless or hard facing (see instructions on
3.c. In semiautomatic or automatic wire welding, the electrode,
container or MSDS) or on lead or cadmium plated
electrode reel, welding head, nozzle or semiautomatic welding
gun are also electrically hot. steel and other metals or coatings which produce
highly toxic fumes, keep exposure as low as
3.d. Always be sure the work cable makes a good electrical possible and within applicable OSHA PEL and
connection with the metal being welded. The connection should
ACGIH TLV limits using local exhaust or
be as close as possible to the area being welded.
mechanical ventilation. In confined spaces or in
3.e. Ground the work or metal to be welded to a good electrical (earth) some circumstances, outdoors, a respirator may
ground. be required. Additional precautions are also
3.f. Maintain the electrode holder, work clamp, welding cable and required when welding on galvanized steel.
welding machine in good, safe operating condition. Replace
5. b. The operation of welding fume control equipment is affected by
damaged insulation.
various factors including proper use and positioning of the
3.g. Never dip the electrode in water for cooling. equipment, maintenance of the equipment and the specific
welding procedure and application involved. Worker exposure
3.h. Never simultaneously touch electrically hot parts of electrode level should be checked upon installation and periodically
holders connected to two welders because voltage between the thereafter to be certain it is within applicable OSHA PEL and
two can be the total of the open circuit voltage of both ACGIH TLV limits.
welders. 5.c. Do not weld in locations near chlorinated hydrocarbon vapors
coming from degreasing, cleaning or spraying operations. The
3.i. When working above floor level, use a safety belt to protect
heat and rays of the arc can react with solvent vapors to form
yourself from a fall should you get a shock.
phosgene, a highly toxic gas, and other irritating products.
3.j. Also see Items 6.c. and 8.
5.d. Shielding gases used for arc welding can displace air and cause
injury or death. Always use enough ventilation, especially in
confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturers instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your employers
safety practices. MSDS forms are available from your welding
distributor or from the manufacturer.
5.f. Also see item 1.b.
4
SAFETY
Refer to
http://www.lincolnelectric.com/safety
for additional safe-
ty information.
Welding Safety
Interactive Web Guide
for mobile devices
5
PRODUCT MODEL TABLE OF CONTENTS
Page
Technical Specifications................................................................................................A-1
Installation.......................................................................................................................Section A
________________________________________________________________________
Routine ..................................................................................................................D-1
Periodic..................................................................................................................D-1
Calibration Specification ........................................................................................D-1
________________________________________________________________________
Safety Precautions.................................................................................................E-1
Troubleshooting ..............................................................................................Section E
Dimension Print......................................................................................................F-3
________________________________________________________________________
________________________________________________________________________
Parts Lists...............................................................................................................P-616
6
MAXSA 10 CONTROLLER PRODUCT DESCRIPTION
PRODUCT DESCRIPTION
GENERAL PHYSICAL DESCRIPTION
SYNERGIC WELDING MODES
The MAXsa 10 CONTROLLER is a user interface and a feeder
controller. The control is used to set all welding parameters A Synergic welding mode offers the simplicity of single knob
and control any travel mechanisms. High-speed digital cables control. The machine will select the correct voltage and
connect the control, wire drive, and the Power Wave power amperage based on the wire feed speed (WFS) set by the oper-
source together. ator.
The MAXsa 10 CONTROLLER is a self-contained control box See the Power Wave AC/DC 1000 SD Operators Manual for
designed to control the entire weld arc at one location. available weld modes.
The user interface utilizes alphanumeric displays for advanced COMMON WELDING ABBREVIATIONS
text messaging providing the end user with an intuitive inter-
face allowing for easy set up and real-time control of all weld- SAW
ing parameters. Submerged Arc Welding
GRAPHIC SYMBOLS THAT APPEAR ON
An eight button memory section has been included which pro-
vides easy storage and recall of stored welding parameters. THIS MACHINE OR IN THIS MANUAL
The user interface can be removed from the control box and
connected as a Pendant for remote control near the arc. PENDENT
ARCLINK
GENERAL FUNCTIONAL DESCRIPTION
CONNECTOR
The MAXsa 10 CONTROLLER is one of the most versatile
user interfaces ever created. Easy to use features make it a
snap to adjust the arc for specific preferences. WIRE FEEDER
The user interface brightly displays essential welding informa-
tion. Use it to quickly adjust weld settings, arc starting para-
meters, arc end parameters and set-up information.
CONTROLLER
The memories allow for up to eight weld schedules to be ARCLINK INPUT
stored and quickly recalled. The user interface allows for mul- CONNECTOR
tiple levels of limits and lockouts.
7
MAXSA 10 CONTROLLER PRODUCT DESCRIPTION
DESIGN FEATURES
SAW
Basic Package
COMMON BASIC EQUIPMENT PACKAGES
Optional kits
8
MAXSA 10 CONTROLLER INSTALLATION
K2814-1 40VDC 1.0 15.0in. 13.0 in 4.0 in. 25 Lbs 14F to 104F -40F to 185F
(381 mm) (259 mm) (102 mm) (11.3 Kg.) (-10C to 40C) (-40C to 85C)
IP 23
A-1
MAXSA 10 CONTROLLER INSTALLATION
A-2
MAXSA 10 CONTROLLER INSTALLATION
STATUS
LIGHT
PENDANT
CONNECTOR
MAXsa 22 or 29
WIRE DRIVE CONNECTOR (14-PIN)
A-3
MAXSA 10 CONTROLLER INSTALLATION
The MAXsa 10 CONTROLLER is a versatile controller. The User 1. Remove the 4 screws from the MAXsa 10 CONTROLLER that
Interface can be removed and used as a hand-held pendant. Most hold the cover. See Figure A.2.
circuits can be accessed through the screwless terminal strip. 2. Remove the 2 screws that hold the pendant in the brackets.
The auxiliary relays can control standard Lincoln equipment, or Use the access holes shown.
they can be used to control any other auxiliary equipment custom 3. Extend the control cable as needed with an Arc Link cable of
controls. PLC interfacing to control starting, stopping, motion, etc, appropriate length. See Figure A.2
can be accomplished with ease.
1 2 Front View
Cover removed
Access
Hole
Cover
K1543-xx
or K2683-xx
Arclink Cable
(Optional)
A-4
MAXSA 10 CONTROLLER INSTALLATION
FIGURE A.3
VAC IN
NEUTRAL (31)
VAC IN
LINE (32)
#2 #1
INSERT INSERT SCREW
WIRE HERE DRIVER HERE
#3
REMOVE SCREW
DRIVER FROM CAGE
CLAMP HOLE.
CAGE CLAMP
A-5
MAXSA 10 CONTROLLER INSTALLATION
D
C
C
A
A
B
B
Numbers Refer to
SHUTDOWN #1 SUPPLY
SHUTDOWN #2 SUPPLY
TRAVEL #2 GND
TRAVEL #1 GND
INCH FORWARD
SHUTDOWN #1
SHUTDOWN #2
INCH REVERSE
CR3 INPUT #4
CR3 INPUT #8
CR1 INPUT #4
CR1 INPUT #8
CR2 INPUT #4
CR2 INPUT #8
531A-48
531B-48
532B-49
532A-49
GND IN
CR3 NO #2
CR3 NO #6
CR3 NC #3
CR3 NC #7
FLUX GND
CR1 NO #2
CR1 NO #6
CR2 NO #2
CR2 NO #6
CR1 NC #3
CR1 NC #7
CR2 NC #3
CR2 NC #7
FLUX FILL
START
STOP
TERMINAL
49
50
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
48
46
47
1
2
3
4
5
6
7
8
9
STRIP
GND-B
GND-C
GND-A
CR1-3
CR1-7
CR2-4
CR2-2
CR2-7
CR3-6
CR1-4
CR1-8
CR3-4
CR3-2
CR3-7
CR1-2
CR1-6
CR2-8
CR2-6
CR2-3
CR3-3
CR3-8
8511
8510
851
855
858
852
853
856
857
859
859
GND
CONTROLLING NON-LINCOLN AUXILIARY EQUIPMENT
Custom motion control and/or other auxiliary equipment can be pow- 7. The supply voltage to power the devices is provided by the end
ered using the terminal strip and relays. To use non-Lincoln motion user. As shipped, the MAXsa 10 has the auxiliary supply blocks
control and/or flux hoppers, follow instructions below. See Figure A.4. (terminal strip blocks #48 and #49) connected to the CR2 relay and
CR3 relay inputs, respectively. When the end user connects a sup-
1. Remove all input power to the MAXsa 10 CONTROLLER including ply to the AUX blocks #48 and #49, this voltage will be jumpered to
any auxiliary power supplies. the CR2 and CR3 relay inputs on terminal strip blocks #11, #17,
and #18.
2. Remove the wire duct cover to gain access to the leads on the right
side of the terminal strip. NOTE: The CR1 relay is not connected to the AUX terminal strip
blocks; the customer must connect power to this relay if it is
3. Remove a plug button from one of the .875 (22.2mm) access to be used. See relay ratings listed earlier.
holes on the bottom of the MAXsa 10 CONTROLLER control box.
Install a suitable strain relief to protect the leads. See Figure A.1. 8. Connect input supply voltage per the Auxiliary Input Power
Connection Instructions listed earlier.
4. Remove the leads going from the terminal strip to the correspond-
ing connectors, i.e. terminal strip blocks #11, #13, and #16 for the 9. The relays can also be used to provide contact closure for any
4-pin TC-3 Travel Carriage or terminal strip blocks #19, #20, and interfacing signals out using the normally open contacts. An exter-
#23 for the 3-pin Automatic Flux Hopper. See the Wiring Diagram. nal auxiliary supply voltage would not be necessary to use the
relays as hard contact closure out signals.
5. These loose leads can be taped and secured in the wire duct.
NOTE: The CR1 relay as shipped does not have AUX leads connect-
6. Any custom or non-Lincoln equipment can be powered by the nor- ed to it. This relay operates as described above and has two
mally open contacts from relays CR1, CR2, or CR3. The contacts normally open / normally closed contacts that could be used
for CR1 are connected to the terminal strip blocks #3 through #8. as a signal out when interfacing to PLCs or custom controls.
The contacts for CR2 are connected to terminal strip blocks #10
through #15. The contacts for CR3 are connected to terminal strip
blocks #17 through #22. See Figure A.3.
CR1 and CR2 relay coils are in parallel and are BOTH turned ON
and OFF as determined by the Travel Options setting (P12 in the
Set-up Menu) as long as the TRAVEL MODE is set to AUTO. CR3
turns ON with the START command and OFF with the STOP
Command.
A-6
MAXSA 10 CONTROLLER INSTALLATION
SHUTDOWN #1 SUPPLY
SHUTDOWN #2 SUPPLY
Jumper
SHUTDOWN #1
SHUTDOWN #2
CR3 NC #7
FLUX GND
START
STOP
22
23
24
25
26
27
40
39
41
GND-C
CR3-7
8511
8510
859
859
Connect STOP
Input Here
The MAXsa 10 CONTROLLER has two shutdown inputs avail- The MAXsa 10 CONTROLLER has a Stop Input available on the
able on the terminal strip. These are independent, normally terminal strip. The Stop Input will work just like pressing the
closed inputs that can be used for limit switches, PLC inputs, STOP Pushbutton. This circuit is in parallel with the STOP
etc, in order to shut down the welding operation for any reason. Pushbutton located on the Switch Panel. Unlike the Shutdown
Shutdown #1 is located on terminal strip blocks #24 and #25. Inputs, which completely shutdown all welding and auxiliary
Shutdown #2 is located on terminal strip blocks #26 and #27. equipment, the STOP Input will allow all welding and auxiliary
motion to continue based on the END OPTIONS configurations in
1. Remove all input power to the MAXsa 10 CONTROLLER the MAXsa 10 CONTROLLER. See Figure A.5.
including any auxiliary power supplies.
1. Remove all input power to the MAXsa 10 CONTROLLER
2. Remove the wire duct cover to gain access to the leads on including any auxiliary power supplies.
the right side of the terminal strip.
2. Remove the wire duct cover to gain access to the leads on
3. Remove one of the plug buttons located on the bottom of the the right side of the terminal strip.
MAXsa 10 CONTROLLER control box and install a box con-
nector to provide strain relief for the auxiliary control leads. 3. Remove one of the plug buttons located on the bottom of the
MAXsa 10 CONTROLLER control box and install a box con-
4. Connect the external shutdown circuit to either of the shut- nector to provide strain relief for the control leads.
down terminal blocks, #24 & #25, and/or #26 & #27. A nor-
mally closed circuit must be connected the MAXsa 10 4. Connect the external Stop Input circuit to terminal blocks #39
CONTROLLER will recognize an open circuit as a shutdown and #41.
command.
NOTE: The STOP circuit only needs a momentary closure to be
5. Remove the shorting jumpers imbedded in the center of the recognized by the MAXsa 10 CONTROLLER.
terminal strip with a small screwdriver for the shutdown cir-
cuits to be used.
A-7
MAXSA 10 CONTROLLER INSTALLATION
K2803-1
Power Wave AC/DC 1000SD
K1543-XX
or K2683-XX
Arclink Cable
K2814-1
MAXsa 10
K1785-XX
14-Pin Cable
K2370-2
MAXsa 22
67 Lead
K231-XX Electrode
Contact Nozzle Weld Cable
K1811-XX
Sense Lead
Work
Work Weld Cable
A-8
MAXSA 10 CONTROLLER INSTALLATION
Notes:
DO NOT DISTURB ANY OTHER HARNESS, LEAD, OR EXISTING GROUND
CONNECTIONS DURING INSTALLATION.
1- Open control box and locate S27981-[ ] (L11087-[ ]) and G4018-[ ] boards.
A-9
MAXSA 10 CONTROLLER INSTALLATION
A-10
MAXSA 10 CONTROLLER OPERATION
SAFETY PRECAUTIONS
Read this entire section of operating instructions
before operating the machine.
WARNING
ELECTRIC SHOCK can kill.
Do not touch electrically live parts
or electrodes with your skin or wet
clothing.
Insulate yourself from the work and
ground.
Always wear dry insulating gloves.
Do not use AC welder if your cloth-
ing, gloves or work area is damp or
if working on, under or inside work-
piece.
Use the following equipment:
-DC manual (stick) welder.
-AC welder with reduced voltage
control.
Do not operate with panels
removed.
Disconnect input power before ser-
------------------------------------------------------------------------
vicing.
------------------------------------------------------------------------
B-1
MAXSA 10 CONTROLLER OPERATION
STATUS
LIGHT
PENDANT
CONNECTOR
MAXsa 22 or 29
WIRE DRIVE CONNECTOR (14-PIN)
START
TRAVEL SWITCH BUTTON
(AUTO / OFF / MANUAL)
FLUX FILL
SWITCH
200 ---- WELD OUTPUT
INDICATOR
ARC START/END
OPTIONS SELECTOR
FREQUENCY AND
BALANCE INDICATOR START OPTIONS
INDICATOR
MEMORY
BUTTONS (8) END OPTIONS
INDICATOR
FEED
REVERSE
FEED
MODE SELECT PANEL FORWARD
CONTROL
B-2
MAXSA 10 CONTROLLER OPERATION
---- 25 ----
POWER-UP SEQUENCE
SETTING FEED FORWARD/REVERSE
When power is first applied to the machine the MODE SELECT
Display reads MAXsa Initializing.... Once the PowerWave While pressing either the FEED FORWARD or FEED REVERSE
AC/DC has initialized (20 to 60 seconds) a lamp test is per- pushbutton the MSP Display will read as shown in Figure B.4 and
formed. the preset wire feed speed will be displayed on the left
(AMPS/WFS) display.
All discrete LEDs, seven segment displays and alpha numer-
ic displays will be turned ON for 2 seconds The feed speed can be changed by adjusting the control knob
below the display while pressing either button.
After 2 seconds all displays are turned OFF again and the
MSP Display will show: FEED REVERSE Use to retract the wire from the feed
mechanism.
B-3
MAXSA 10 CONTROLLER OPERATION
To select a weld mode, press the WELD MODE SELECTOR button Press the WELD MODE selector until the MSP Display reads
until the WELD MODE indicator comes ON (it may already be lit by Balance. If the selected mode allows for balance adjustment,
default at power up). Turn the control knob to select the desired the Control Knob can be used to select the desired wave balance
mode. After about 1 second, the parameters for the new mode will through a range of 25% to 75%.
be displayed. These parameters can be adjusted with the control
knobs below each display.
60
Hz
Balance
-500
NOTE: CC Modes will show AMPS in the upper left display. CV
Modes will show wire feed speed and the WFS indicator -1000
will be lit.
FREQUENCY/BALANCE CONTROL Adjusting the Balance (the ratio between Positive and Negative
half cycle on time) changes the deposition for more efficient
welding.
FREQUENCY ADJUST
OFFSET ADJUST
Press the WELD MODE selector until the FREQUENCY/BALANCE
indicator comes ON and the MSP Display reads Frequency. If the
Press the WELD MODE selector until the MSP Display reads
selected mode allows for frequency adjustment, the Control Knob
Offset. If the selected mode allows for offset adjustment, the
can be used to select the desired frequency between 20 and
Control Knob can be used to select the desired offset. The amount
100hz.
of offset allowed is determined by the selected weld mode.
60 0
Hz
percent
Frequency
DC Offset
0
0
-500
-500
B-4
MAXSA 10 CONTROLLER OPERATION
0 90
2 Arc
X X X X
0 90 180
During the search process, pressing the right pushbutton typically System
3 Arc
acts as a next button and the left pushbutton typically acts as a X X X
0 90 180 270
System
back button. Pressing the control knob also acts as a next 4 Arc
button. X X
0 90 180 270 0
System
5 Arc
X
0 90 180 270 0 90
System
Rotate the control knob then press to select relevant welding
6 Arc
details such as welding process, wire type, wire size, etc. System
When the final selection is made, the MAXsa 10 will automati- (for balanced waveforms only)
cally change to the weld mode found by the Weld Mode Search
process. See the Power Wave AC/DC Operators Manual for more informa-
tion regarding the configuration of multiple arc systems.
Earlier products may not have this feature. To activate this fea-
ture, a software update may be needed from www.power-
wavesoftware.com
B-5
MAXSA 10 CONTROLLER OPERATION
Arc Start
Delay Strike Start Upslope Weld Downslope Crater Burnback
Output
Time
Wire Touches
Start Button
Wire Begins
End of Start
End of Crater
Downslope
Stop Button
Pressed
Upslope
Burnback
to Feed
End of
End of
Pressed
Plate
Timer
End of
Timer
WELD SEQUENCE START OPTIONS OPERATION
The weld sequence defines the weld procedure from beginning to Pressing the Arc Start/End Options pushbutton will illuminate the
end. All adjustments are made through the user interface. START OPTIONS LED and the Arc Delay Time parameter will show
on the MSP Display.
STRIKE settings are valid from the beginning of the sequence Repeated pressing of the Arc Start/End Options pushbutton will
(Start) until the arc is established. They control run-in (speed at scroll through the parameters. Turning the Mode Select Panel
which the wire approaches the workpiece) and provide the Control, while on a parameter will change its value.
power to establish the arc. Typically output levels are
increased, and WFS is reduced during the strike portion of the
weld sequence. When a Start Option is set to a value other than OFF, the START
OPTIONS LED will blink synchronous with the WFS or Amps and/or
START values allow the arc to become stabilized once it is the volts LED located on the Dual Display Panel prompting the
established. Extended start times or improperly set parameters user to enter these parameters. The parameters that can be set
can result in poor starting. by the user in the START OPTIONS will be as follows:
UPSLOPE TIME determines the amount of time it takes to ramp ARC DELAY TIME
from the start parameters to the weld parameters. The transi- STRIKE WFS
tion is linear and may be up or down depending on the rela- STRIKE TIME
tionship between the start and weld settings. START WFS/AMPS
START VOLTS
START TIME
UPSLOPE TIME
B-6
MAXSA 10 CONTROLLER OPERATION
END OPTIONS
The downslope, crater, and burnback parameters are used to Repeated pressing of the Arc Start/End Options pushbutton will
define the end of the weld sequence. The are defined in the fol- toggle through the parameters. Turning the Mode Select Panel
lowing: Control while on a parameter will change its value. When the
Crater Time is set to a value other than OFF, the END OPTIONS
DOWNSLOPE determines the amount of time it takes to ramp LED will blink synchronous with the WFS or Amps LED (depending
from the weld parameters to the crater parameters. The transi- on CC or CV Weld Modes) and with the Volts LED located on the
tion is linear and may be up or down depending on the rela- Dual Display Panel prompting the user to enter these parameters.
tionship between the weld and crater settings. The parameters that can be set by the user in the END OPTIONS
will be as follows:
CRATER parameters are typically used to fill the crater at the
end of the weld and include both time and output settings. DOWNSLOPE TIME
CRATER WFS/AMPS
BURNBACK defines the amount of time the output remains on CRATER VOLTS
after the wire has stopped. This feature is used to prevent the CRATER TIME
wire from sticking in the weld puddle and to condition the end BURNBACK TIME
of the wire for the next weld. A burnback time of 0.4 second is RESTRIKE TIME
sufficient in most applications.
RESTRIKE TIME determines how long the system will try to re-
establish the arc in the event of a poor start or if the arc goes
out for any reason (short circuit or open circuit). During
restrike, the WFS and outputs are driven in an attempt to re-
establish the arc.
OFF
Downslope Time
Use the Mode Select Panel Control to select the desired delay
time. Press the Weld Mode Selector to exit the End parameters.
B-7
MAXSA 10 CONTROLLER OPERATION
PARAMETER DEFINITION
P.1 through P.99 Unsecured Parameters (always adjustable)
P.101 through P.199 Diagnostic Parameters (always read only)
P.501 through P.599 Secured Parameters (only accessible with Weld Manager)
To access the Setup Menu, Press the Left Button and Right Button Scroll through the preference options by rotating the Control
simultaneously. The Setup Menu Indicator will light and the lower Knob. Change the preference setting by pressing the Right Button.
display will read as shown below. To cancel, press the Left Button.
Note: The Setup Menu cannot be accessed during welding, or if a
fault is displayed. To resume welding, exit the Setup Menu. 4. EXIT
Mode Select
Panel (MSP)
Setup Menu
P. 0 Indicator
User Prefs
Exit
Parameter Definition
This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
Exit Setup Menu
This option selects which units to use for displaying wire feed speed. English = inches/minute
P.1 Wire Feed Speed Units
wire feed speed units (default). Metric = meters/minute wire feed speed units.
This option selects what value will be shown on the upper left display while welding. Amps =
P.2 Arc Display Mode
The left display shows Amperage while welding (default). WFS = The left display shows Wire
Feed Speed while welding.
If the previous software revision had this parameter set to display energy, that selection will
remain.
This option selects the information displayed on the alphanumeric displays while welding. Not all
P.3 selections will be available on all machines. In order for each selection to be included in the
list, the power source must support that feature. A software update of the power source may be
needed to include the features.
Standard Display = The lower displays will continue to show preset information during and after
a weld (default). Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.
This option allows the adjustment of the start and end travel options for a travel carriage. Press
P.12 Travel Carriage Start/Stop - Travel Starts
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.
This option allows the adjustment of the start and end travel options for a travel carriage. Press
P.12 Travel Carriage Start/Stop - Travel Ends
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.
This option allows the adjustment of Arc Force values for Start, Weld and Crater. Press the
P.13 Arc Force Adjustment Options
Right Button to enter the option and rotate the Control Knob to select the desired weld state to
adjust. Press the Right Button again to adjust the value on the upper Left Knob. Press the Left
Button to save the value and back out to select another weld state. Rotate the Control Knob to
make another selection, or press the Left Button to exit this option. This option will not appear if
the presently selected weld mode does not support Arc Force.
Use this option to reset the initial weight of the consumable package. Press the Right Button to
P.14 Reset Consumable Weight
reset the consumable weight. This option will only appear with systems using Production
Monitoring.
B-9
MAXSA 10 CONTROLLER OPERATION
This option allows enabling or disabling touch sense when feeding wire forward.
P.15 Hot-Inch Touch Sense Option
Disabled = Touch sensing is disabled when feeding the wire forward (default).
Enabled = Touch sensing is active when feeding the wire forward.
When enabled and feeding wire forward, the wire is electrically "hot" and waiting to short to the
plate. When a short occurs, the wire feed automatically stops and the flux hopper relay is acti-
vated until the feed forward button is released.
This option selects the Wire Drive Gear Ratio that will be used. The possible selectable values
P.18 Wire Drive Gear Ratio
are read from the Wire Drive on startup. For semi-automatic systems, if the feedhead board has
dip switches, this option does not appear in the menu. Gear ratio can be selected using the dip
switches.
This option allows selection of the Shutdown 2 input function on the control box. Normal
P.21 Shutdown 2 Function Select
Shutdown = The Shutdown 2 input functions as a standard shutdown input that locks out all
input buttons (default) Output Disable = The Shutdown 2 input functions as a machine output
lockout to disable the welding circuit but still allow cold feeding of the wire.
For Sub-Arc Lead Arc machines only. Allows the Lead Arc MAXSA 10 to control all machine trig-
P.23 Trigger Fan-Out
gers in a multi-arc system.
No = Only the machine connected to the MAXSA10 can be triggered on and off (default).
Yes = All machines in the system can be triggered on and off simultaneously.
This option allows the front panel controls of the MAXSA 10 to be enabled/disabled. The remote
P.30 Input Control
inputs are always functional when connected, but there may be applications where it is neces-
sary to disable the inputs on the pendent. Panel & Remote = All pendent buttons are enabled
(default). Panel Locked = The Start, Flux and feed buttons are disabled at the pendent. The
pendent's Stop button is always active and cannot be disabled.
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
P.80 Sense From Studs
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other
machine settings (default).
True = Voltage sensing is forced to "studs".
Most power sources contain weld modes used for calibration and test purposes. By default, the
P.99 Show Test Modes?
machine does not include test weld modes in the list of weld modes that are available to the
operator. To manually select a test weld mode, set this option to "Yes". When the power source
is turned off and back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and cannot be used
for welding.
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes"
P.100 View Diagnostics?
to access the diagnostic options in the menu. Additional parameters will now appear in the
setup menu (P.101, P.102, etc).
B-10
MAXSA 10 CONTROLLER OPERATION
Parameter Definition
Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate
P.101 View Event Logs
Control Knob to select the desired event log to read. Press the Right Button again to enter the
selected log. Rotating the Control Knob will scroll through the event log, displaying the log
index number, event code and some other data. Press the Left Button to back out to select
another log. Press the Left Button again to exit this option.
Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate
P.102 View Fatal Logs
Control Knob to select the desired fatal log to read. Press the Right Button again to enter that
log. Rotating the Control Knob will scroll through the log, displaying the log index number and
fatal code. Press the Left Button to back out to select another log. Press the Left Button again to
exit this option.
Used for viewing the software versions for each board in the system. Press the Right Button to
P.103 View Software Version Information
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the firmware version. Press the Left Button to back out to select another
board. Rotate the Control Knob to select another board, or press the Left Button to exit this
option.
Used for viewing the hardware version for each board in the system. Press the Right Button to
P.104 View Hardware Version Information
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the hardware version. Press the Left Button to back out to select another
board. Press the Left Button again to exit this option.
Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld
P.105 View Welding Software Information
Set version. Press the Left Button to back out and exit this option.
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to
P.106 View Ethernet IP Address
read the IP Address. Press the Left Button to back out and exit this option. The IP address can-
not be changed using this option.
Used for viewing the type of power source the feeder is connected to. Press the Right Button to
P.107 View Power Source Protocol
identify the power source as either LincNet or ArcLink. Press the Left Button to back out and exit
this option.
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire
P.501 Encoder Lockout
feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld
mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right
knob will always function as an on/off switch. This parameter can only be accessed using Power
Wave Manager software.
B-11
MAXSA 10 CONTROLLER OPERATION
Parameter Definition
Disables the specified memory button(s). When a memory is disabled, welding procedures can-
P.503 Memory Button Disable
not be restored from or saved to that memory. If an attempt is made to save or restore a dis-
abled memory, a message will be displayed on the lower display indicating the memory number
is disabled. In multi-head systems, this parameter disables the same memory buttons on both
feed heads. This parameter can only be accessed using Power Wave Manager software.
Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel
P.504 Mode Select Panel Lock
selection is locked and an attempt is made to change that parameter, a message will be dis-
played on the lower display indicating the parameter is locked.
All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are
unlocked.
All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.
Start & End Options Locked = The Start and End parameters on the Mode Select Panel are
locked, all others are unlocked.
Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,
all others Mode Select Panel settings are unlocked.
Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are
locked, all others are unlocked.
Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the
Mode.
Select Panel are locked, all others are unlocked.
Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the
Mode. Select Panel are locked, all others are unlocked.
This parameter can only be accessed using Power Wave Manager software.
Determines if the setup parameters can be modified by the operator without entering a pass-
P.505 Setup Menu Lock
code.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
B-12
MAXSA 10 CONTROLLER OPERATION
Parameter Definition
Prevents unauthorized changes to the equipment. The default passcode is zero which allows
P.506 Set User Interface Passcode
full access. A nonzero passcode will prevent unauthorized: changes to memory limits, saving to
memory (if P.502 = Yes), changes to setup parameters (if P.505 = Yes).
This parameter can only be accessed using Power Wave Manager software.
Locks all user interface controls, preventing the operator from making any changes. This para-
P.509 UI Master Lockout
TOUCH SENSE
WARNING
If the Touch Sense is enabled the Power Source output is ON
as long as the Feed Forward button is held. Avoid touching
any portion of the weld circuit while feeding down.
LOCKOUT / SECURITY
Note that when an option is locked, its value can still be moni-
tored. For example, if start and end options are locked, the
welder can still press the right Mode Select Panel Pushbutton
and see the value set for Start Time. If the welder attempts to
change its value, a message will briefly appear on the Mode
Select Panel indicating "MSP Option is LOCKED
B-13
MAXSA 10 CONTROLLER OPERATION
MAKING A WELD
Once the necessary parameters have been set and the desired Weld Mode selected:
Press the START BUTTON to begin welding. Press the STOP BUTTON to end the weld.
The ARC ESTABLISHED INDICATOR will flash as the wire If End parameters have been set, they will take effect for the
feeds towards the work piece to show that OCV is present and specified time.
switch to ON when the arc is lit.
If the TRAVEL function is selected it will stop moving as pre-
If Start parameters have been set they will be in effect for scribed in the P.12 Parameter setting.
the specified time and then the Weld Mode parameters will
take effect. The ARC ESTABLISHED INDICATOR will go OFF when the
power source output is disabled (after Burnback).
The two upper displays will indicate the actual parameters
as the weld progresses. The displays will return to the idle state in preparation for the
next weld.
If the TRAVEL function is selected it will begin moving as pre-
scribed in the P.12 Parameter setting.
ARC ESTABLISHED
INDICATOR
200 30.5
START
58 BUTTON
Steel 1/8
CC DC +
STOP
BUTTON
B-14
MAXSA 10 CONTROLLER OPERATION
Voltage NOTE: This can only be done with Memory locations that have
the same Weld Mode.
Frequency
While welding, any Memory location trying to be accessed with a
Balance different Weld Mode than the one currently being used will be
ignored and an error message will be displayed. Up to eight dif-
DC Offset ferent weld procedures can be used while actively welding by
using all of the memory locations, as long as each location utilizes
Arc Start options the same Weld Modes.
Arc End Options
Memory saving can be optionally disabled using Lockout Levels. If
the user attempts to save a procedure to memory location that is
NAMING A SAVED PROCEDURE locked, the Mode Select Panel will briefly display "Memory Save is
DISABLED!". Presently, Memory Panel Lockout Levels can only be
Procedures stored in memory can be given a name that the user accessed through Weld Manager.
will easily recognize such as Root Pass Fill Pass or Cap
Pass. As with the Lockout Option. this option is only available
through the use of Weld Manager.
B-15
MAXSA 10 CONTROLLER OPERATION
200 30.5
MSP
DISPLAY
58
Steel 1/8
CC DC +
LED
INDICATOR
MEMORY
BUTTON
Hold for 2 Seconds Memory 1
to Save Saved
B-16
MAXSA 10 CONTROLLER OPERATION
Save Limits
Yes No
Memory 1
Set Limits
B-17
MAXSA 10 CONTROLLER NOTES
B-18
MAXSA 10 CONTROLLER ACCESSORIES
1. Go to www.lincolnelectric.com
2. In the Search field type E9.181 and click on the Search icon
(or hit Enter on the keyboard).
All of the information for the Power Wave System accessories can
be found in this document.
C-1
MAXSA 10 CONTROLLER MAINTENANCE
WARNING Check weld cables, control cables and gas hoses for cuts.
ELECTRIC SHOCK can kill.
Do not touch electrically live parts such as PERIODIC MAINTENANCE
output terminals or internal wiring.
N/A
When inching, electrode and drive mecha-
nism are hot to work and ground and CALIBRATION SPECIFICATION
could remain energized several seconds
after the inch button is released. All calibration is factory set on the MAXsa 10 CONTROLLER.
D-1
MAXSA 10 CONTROLLER TROUBLE SHOOTING
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained
Personnel. Unauthorized repairs performed on this equipment may result in
danger to the technician and machine operator and will invalidate your factory
warranty. For your safety and to avoid Electrical Shock, please observe all safety
notes and precautions detailed throughout this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-1
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
TABLE E.1
Light Meaning
Condition
Steady Green System OK. Power source is operational, and is communicating normally with all healthy
peripheral equipment connected to its ArcLink network.
Blinking Green Occurs during power up or a system reset, and indicates the POWER
WAVE i400 is mapping (identifying) each component in the system. Normal
for first 1-10 seconds after power is turned on, or if the system configuration is
changed during operation.
Fast Blinking Green Under normal conditions indicates Auto-mapping has failed.
Also used by the Diagnostics Utility (included on the POWER WAVE Utilities
and Service Navigator CDs or available at www.powerwavesoftware.com) to
identify the selected machine when connecting to a specific IP address.
Alternating Green and Red Non-recoverable system fault. If the Status lights are flashing any combination
of red and green, errors are present. Read the error code(s) before the
machine is turned off.
Error Code interpretation through the Status light is detailed in the Service
Manual. Individual code digits are flashed in red with a long pause between
digits. If more than one code is present, the codes will be separated by a
green light. Only active error conditions will be accessible through the Status
Light.
Error codes can also be retrieved with the Diagnostics Utility (included on the
POWER WAVE Utilities and Service Navigator CDs or available at
www.powerwavesoftware.com). This is the preferred method, since it can
access historical information contained in the error log.
To clear the active error(s), turn power source off, and back on to reset.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
Err 32 Capacitor bank "A" under 1. The power source input power
voltage. may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.
If all recommended possible areas of
2. See the power source Instruction misadjustment have been checked
Manual. and the problem persists, Contact
your local Lincoln Authorized Field
Err 33 Capacitor bank "B" under 1. The power source input power Service Facility.
voltage. may be wired incorrectly. Verify
the power source reconnect panel
wiring matches the input power.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
ARCLINK SYSTEM ERROR CODES
Err 35 Capacitor bank "B" overvolt- 1. The power source input power
age. may be wired incorrectly. Verify
the power source reconnect
panel wiring matches the input
power.
Err 41 Long term secondary over- 1. The power source has exceeded If all recommended possible areas of
current. the output current limits. Adjust misadjustment have been checked
the welding procedure to reduce and the problem persists, Contact
the current draw. The welding your local Lincoln Authorized Field
procedure may exceed the Service Facility.
capacity of the power source.
Err 43 Capacitors are out of bal- 1. Verify the power source recon-
ance nect panel wiring matches the
input power.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Err 81 Motor overload, long term. 1. The wire drive motor has over-
heated. Check that the electrode
slides easily through the gun and
cable.
2. Remove tight bends from the gun
and cable.
3. Check that the spindle brake is
not too tight.
4. Verify a high quality electrode is
being used.
5. Wait for the error to reset and the If all recommended possible areas
motor to cool (approximately 1 of misadjustment have been
minute). checked and the problem persists,
6. Long term average motor current Contact your local Lincoln
limit has been exceeded. Authorized Field Service Facility.
Typically indicates mechanical
overload of system. If problem
continues consider higher torque
gear ratio (lower speed range).
Err 82 Motor overload, short term. 1. The wire drive motor current draw
has exceeded limits, usually
because the motor is in a locked
rotor state. Check that motor can
turn freely when idle arm is open.
2. Verify that the gears are free of
debris and dirt.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Err 263 No usable weld modes. 1. The power source does not have
ARCLINK SYSTEM ERROR CODES
N/A User Interface " Limits Exceed " When a mode is selected with a work point low limit
"Gear Box Type" greater than the high WFS limit. (no event is logged)
28 Feeder OUTPUT DISABLED The shutdown 2 input on the Feeder Board is open and
P.21 is selected for Output Disable
83 Feeder " UI Shutdown 1 " The shutdown 1 input on the Feeder Board is open.
84 Feeder " UI Shutdown 2 " The shutdown 2 input on the Feeder Board is open.
Typical User Interface 3 digit error codes (not blinked on the status LED).
213 Power Source User Interface could not communicate with control board
is Off-Line in power source.
215 Feeder Board is Off-Line Either no feed head board is connected, being repro-
grammed or experiencing a fatal event.
247 N/A Arc control has a latched fault. The UI will indicate a
Reset button needs to be pressed to clear the fault.
274 N/A Weld set change required clearing of user memory.
275 N/A UI memory could not be saved. Contact Lincoln Electric
Service Department for further support.
276 N/A UI memory could not be restored. Contact Lincoln
User Interface Electric Service Department for further support.
277 N/A UI memories were converted due to change in number of
UI parameters. Info only.
278 N/A UI limits were converted due to change in number of UI
parameters with limits. Info only.
281 (Varies based on the Internal Error. Collect all displayed values and contact
error type and who Lincoln Electric Service Department.
caused the error)
282 (Varies based on the Internal Error. Collect all displayed values and contact
error type and who Lincoln Electric Service Department.
caused the error)
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-6
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Typical User Interface 3 digit error codes (not blinked on the status LED).
Error Source UI Text Reason
Code
283 (Varies based on the Internal Error. Collect all displayed values and contact
error type and who Lincoln Electric Service Department.
caused the error)
285 N/A UI memory could not be restored. Contact Lincoln
Electric Service Department for further support.
612 User Interface {" Phase Gen Init "}, 1 = Initializing Phase Generator
{"Duplicate Arc # "}, 2 = Duplicate Arc #'s found
{" Mult Lead Arcs "}, 3 = Mult Lead Arcs found
{" Missing an Arc "}, 4 = Missing a Trail Arc
{" Too Many Arcs "}, 5 = Too Many Arcs
{"Missing Lead Arc"}, 6 = Missing Lead Arc
{" Missing an Arc "} 7 = Trail Arc dropped communication with Lead Arc
The feeder does not power up - no 1. The Power Wave power source is
display, no feed. OFF. Turn ON the Power Wave
source.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-7
MAXSA 10 CONTROLLER TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Inconsistent wire feeding or wire not 1. The electrode is rusty or dirty. Use
OUTPUT PROBLEMS
feeding but drive rolls turning. only clean electrode. Use quality
electrode, like L-50 or L-56 from
Lincoln Electric.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-8
MAXSA 10 CONTROLLER NOTES
E-9
MAXsa 10 CONTROLLER WIRING DIAGRAM (CODES 11590, 11777)
5-PIN ARCLINK
PLUG
L1
TERMINAL
CAN BUS LOW A 541E
STRIP
CAN BUS HIGH B 542E
L2
ELECTRODE SENSE C 67 1
40VDC CAN POWER D 540E
2
REMOTE P.C. BOARD
E
MAXSA 10 CONTROLLER
-
A 831 836 6 2
14-PIN MOTOR MOTOR + 3 GND-B 16 TRAVEL #2 GND D
DIODE
RECEPTACLE MOTOR - B 832 +
4 CR3
BRIDGE CR3-4 17 CR3 INPUT #4
C 833A 5
CR3 INPUT #8
6 CR3-8 18
J87
D 834A
7
841 W 1 CR3-2 19 CR3 NO #2
E 845B/G L9 842 R 2 8 J332 CR3-6 20 CR3 NO #6
843B/R 9 L7
F 847 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SHIELDED
844B/W 4
10 CR3-3 21 CR3 NC #3 A
TACH + 15VDC G 841 W CABLE J84 11
845G/W 5 CR3-7 22 CR3 NC #7 B
846 G TRAVEL 12
TACH COMMON H 844B/W 6
847 RELAY #2 13 GND-C 23 FLUX GND C
7
I 14
8 859 24 SHUTDOWN #1 SUPPLY
J 67A J85 J86 15
ELECTRODE SENSE SHUTDOWN #1
16 8510 25
TACH 1A DIFF IN K 842 R
3-PIN FLUX
CR1 859 26 SHUTDOWN #2 SUPPLY
TACH 1B DIFF IN L 843B/R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 1 8511
RECEPTACLE
27 SHUTDOWN #2
M 846 G 3312 2
3 28
1
ELECTRODE SENSE N 67C
4 29
2
5 3
851 853 855 857 859 8511 8513 30
6 4
J331
852 856 858 8510 8514 7 5 31
3318 8 J33 FLEX
6 32
FLEX
9 7
F-1
10 8 33
W B 11
PENDANT CHASSIS 9 34
12 10
CONNECTION
L6
35
36
37
N.A. RED / GREEN 38
B1
STATUS LED 851 39 SWITCH GROUP #1 SUPPLY
852 40 START
L10
853 41 STOP
500E
540D 42
J31
542D 855 43 SWITCH GROUP #2 SUPPLY
1 2 4 3
L11 541D 856 44 INCH FORWARD
J2
1 2
67B AUXILIARY INPUT GROUND
START AUXILIARY INPUT LINE (32)
S3 8514 AUXILIARY INPUT NEUTRAL (31)
J1
328
67A STANDARD LINCOLN AUXILIARY
327
328A 326 EQUIPMENT 115VAC CIRCUIT INPUT VOLTAGE MUST BE 115VAC FOR
1 2 3 4 5 6
STOP 8513 MUST BE FUSED FOR 10A, LINCOLN AUXILIARY EQUIPMENT. THE
328B 325 MAXsa10 IS WIRED FOR LINCOLN TC-3
SLOW BLOW
J32
S4 324 TRAVEL CARRIAGE AND AUTOMATIC CONTROLLER
323 FLUX HOPPER. BY CONNECTING
328C 115VAC TO 48, 49, & 50, LINCOLN FLUX
HOPPER AND TC-3 WILL OPERATE.
1 2 3 4 5 6 7 8
S2 COMPONENT VALUE UNITS:
FLUX
CAPACITOR: MFD/VOLTS
RESISTOR: OHMS/WATTS
LEAD COLOR CODING
B=BLACK
PENDANT G=GREEN CONNECTOR PIN NUMBERS:
N=BROWN
R=RED EX. 12 PIN CONNECTOR
U=BLUE
W=WHITE 1 2 6
7 12
LATCH
G5118
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the
DIAGRAMS
machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
MAXsa 10 CONTROLLER WIRING DIAGRAM (CODE #12327)
5-PIN ARCLINK
PLUG
L1
TERMINAL
CAN BUS LOW A 541E
STRIP
CAN BUS HIGH B 542E
L2
ELECTRODE SENSE C 67 1
40VDC CAN POWER D 540E
2
COMMON E 500E
3
MAXSA 10 CONTROLLER
-
14-PIN MOTORMOTOR + A 831 836 6 0 1
DIODE 4 8
GND-B 16 TRAVEL #2 GND D
RECEPTACLE MOTOR - B 832 + CR3
BRIDGE CR3-4 17 CR3 INPUT #4
C 833A 2 6
3 7 CR3-8 18 CR3 INPUT #8
D 834A
841 W 1 CR3-2 19 CR3 NO #2
E 845B/G L9 4 8
842 R 2 CR3-6 20 CR3 NO #6
F 847 843B/R 3 2 6 L7
SHIELDED
844B/W 4
CR3-3 21 CR3 NC #3 A
TACH + 15VDC G 841 W CABLE J84
845G/W 5 TRAVEL CR3-7 22 CR3 NC #7 B
TACH COMMON H 844B/W 846 G 6 RELAY #2 GND-C 23 FLUX GND C
847 7
I
8 859 24 SHUTDOWN #1 SUPPLY
ELECTRODE SENSE J 67A J85 J88
8510 25 SHUTDOWN #1
TACH 1A DIFF IN K 842 R 0 1
CR1 859 26 SHUTDOWN #2 SUPPLY 3-PIN FLUX
TACH 1B DIFF IN L 843B/R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 8511
RECEPTACLE
27 SHUTDOWN #2
M 846 G 3 7 28
ELECTRODE SENSE N 67C
29
4 8
851 853 855 857 859 8511 8513 30
2 6
852 856 858 8510 8514 31
32
F-2
33
PENDANT CHASSIS W B 34
CONNECTION
L6
35
36
37
N.A. RED / GREEN 38
B1
STATUS LED 851 39 SWITCH GROUP #1 SUPPLY
852 40 START
L10
853 41 STOP
500E
540D 42
J31
542D 855 43 SWITCH GROUP #2 SUPPLY
1 2 4 3
L11 541D 856 44 INCH FORWARD
J2
1 2
67B AUXILIARY INPUT GROUND
START AUXILIARY INPUT LINE (32)
S3 8514 AUXILIARY INPUT NEUTRAL (31)
J1
328
67A STANDARD LINCOLN AUXILIARY
327
328A 326 EQUIPMENT 115VAC CIRCUIT INPUT VOLTAGE MUST BE 115VAC FOR
1 2 3 4 5 6
STOP 8513 MUST BE FUSED FOR 10A, LINCOLN AUXILIARY EQUIPMENT. THE
328B 325 MAXsa10 IS WIRED FOR LINCOLN TC-3
SLOW BLOW
J32
S4 324 TRAVEL CARRIAGE AND AUTOMATIC CONTROLLER
323 FLUX HOPPER. BY CONNECTING
328C 115VAC TO 48, 49, & 50, LINCOLN FLUX
HOPPER AND TC-3 WILL OPERATE.
1 2 3 4 5 6 7 8
S2 COMPONENT VALUE UNITS:
FLUX
CAPACITOR: MFD/VOLTS
RESISTOR: OHMS/WATTS
LEAD COLOR CODING
B=BLACK
PENDANT G=GREEN CONNECTOR PIN NUMBERS:
N=BROWN
R=RED EX. 12 PIN CONNECTOR
U=BLUE
W=WHITE 1 2 6
7 12
LATCH
G8068
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the
DIAGRAMS
machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
8.90
1.50 1.64
5.89 7.75
MAXSA 10 CONTROLLER
.20 PENDANT
11.30
7.07
SCALE = 1 : 4
13.25
12.25
F-3
11.68
14.40
O .28
O .66
.87
L13444
DIAGRAMS
MAXSA 10 CONTROLLER NOTES
F-4
CUSTOMER ASSISTANCE POLICY
The business of The Lincoln Electric Company is manufacturing and
selling high quality welding equipment, consumables, and cutting
equipment. Our challenge is to meet the needs of our customers and
to exceed their expectations. On occasion, purchasers may ask
Lincoln Electric for advice or information about their use of our
products. We respond to our customers based on the best information
in our possession at that time. Lincoln Electric is not in a position to
warrant or guarantee such advice, and assumes no liability, with
respect to such information or advice. We expressly disclaim any
warranty of any kind, including any warranty of fitness for any
customers particular purpose, with respect to such information or
advice. As a matter of practical consideration, we also cannot assume
any responsibility for updating or correcting any such information or
advice once it has been given, nor does the provision of information
or advice create, expand or alter any warranty with respect to the sale
of our products.
Lincoln Electric is a responsive manufacturer, but the selection and
use of specific products sold by Lincoln Electric is solely within the
control of, and remains the sole responsibility of the customer. Many
variables beyond the control of Lincoln Electric affect the results
obtained in applying these types of fabrication methods and service
requirements.
Subject to Change This information is accurate to the best of our
knowledge at the time of printing. Please refer to
www.lincolnelectric.com for any updated information.
TABLE OF CONTENTS
PRODUCT DESCRIPTION
INSTALLATION
OPERATION
ACCESSORIES
MAINTENANCE
TROUBLE SHOOTING
DIAGRAMS