In the event that the Digitool password has been lost and the unit is locked, follow these steps to
unlock the unit and restore the password to the factory default of 1234.
Note: This procedure also resets the display contrast, Automix Weighting and the Serial Network Address to the
factory defaults - but does not affect presets.
STEPS
1. Open the terminal window in the PC utility using the Utilities drop-down menu.
2. In the 'Command' text area of the terminal window (bottom of window) type the command 'boote'
and then press enter.
BOOTE
BOOTE
>
5. Wait for the EEPROM update message to clear (this may take a few minutes).
6. After the message clears, the unit will be unlocked and the password is reset to the factory default
of '1234'.
If your display is not visible after this procedure, use the PC Utilities drop-down menu item 'LCD Contrast' to
correct the display.