Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 7

RESUME

HARESHKUMAR D. CHAUHAN
A/5, Pramukh Swami Park,
Near Sterling Flats,

Top performing maintenance engineer, adept in planning, testing, executing, evaluating and
diagnosing, and routine upkeep of equipment, machinery and systems in the production area.
Also having experience in shutdown jobs and commissioning jobs.
Worked over 11 years in maintaining different kind of facilities, demonstrating the following core skills:
Accuracy Attention to minute details.
Exceptional problem solving and analytical abilities.
Excellent communication, managerial and interpersonal skills.
Ability to work in a team environment and collaborate with cross-company departments.
PROFESSIONAL EXPERIENCE : 12.5 years
WITH OIL- GAS & PETROCHEM ICAL INDUSTRIES: Total 5.5 Years
Presently I am working as an Electrical Engineer with a Sinclus Engineering & Consulting at
Reliance Industries ltd. Jamnagar since October 2015.
I have worked as Electrical Engineer with Essar Oil Ltd. Jamnagar since Sept 2015 to
October 2015.
I have worked as Electrical Supervisor at Qatar Shell GTL since Jan 2015 to April 2015.
I have worked as Maintenance Engineer with a contractor firm, Aarvi Encon at Reliance
Industries Hazira since August 2014 to December 2014.
I have worked with QATAR ENGINEERING & CONSTRUCTION COMPANY WLL since
March 2014 to May 2014.
I have worked as Maintenance Tech. with a contractor firm, RESHMI ELECTRICALS at GAIL
INDIA LTD., Gandhar Plant since October 2004 to April 2006.
I have worked as Maint. Engineer with a contractor firm, SHREE RAM ELECTRICALS at
RELIANCE INDUSTRIES LTD., Hazira Plant since December 1997 to December 1999.

WITH GALVANIZING & ROLLING MILL INDUSTRIES: Total 7 years


I have worked as Deputy Manager with m/s STEELCO GUJARAT LTD., Palej Since
February 2007 to December 2012.
I have worked as Maintenance Engineer with SIBA , SENEGAL, West Africa since
December 2012 to January 2014

EDUCATIONAL QUALIFICATION:
Course Board/University Year Of Passing Percentage
Obtained
SSC GSEB, March 1994 71.43%
Gandhinagar
DEE M.S. University, Sept. 1997 62%
Baroda
BE Electrical SVNIT, Surat June 2006 51.10%

I have completed CPP Course from Prolific System & Technologies Pvt.
I have completed Radiation Safety Trainings course from BARC Mumbai.

PRESENT EXPERIENCE: Presently I am working as an Electrical Engineer with Reliance


Industries ltd., Jamnagar at Commissioning project of CPP.
Commissioning of Sub-Station 33 KV & 220 KV GIS & 6.6 KV AIS.
Testing & Commissioning of HT/LT Motors
Testing & Commissioning of Transformer up to 160 MVA, up to 220KV
Testing & Commissioning of HT/LT Panel, PCC,PMCC,MCC,PDB,LDB
Commissioning of UPS, Inverter & Battery Charger Panels
Testing of CT & PT, ACB, VCB, RELAYS.
Cold loop & Hot loop checking
BOM checking
Cable Laying & Testing

JOB RESPONSIBILITIES:
Handles commissioning and test substation automation systems such as Relays, Annunciators,
Substation Computers and Communication Gateways LANS for AIS and GIS Substations with
voltages 4.16 KV up to 220 KV will also provide technical support to Protection and Control
Engineers and assist Project Teams in developing project scope, resources and schedule
requirements.

Prepare test plans, supervise and coordinate commissioning activities for Power
Transformers, Voltage Regulators, CBs, PTs, CTs, HV Switches and Station Service
Equipment and AC/DC System such as UPS, Chargers, Batteries and Transfer Switches.

Test conducted on CT:


Ratio, Insulation Resistance, Winding Resistance, Knee point voltage (for protection class), Polarity.

Test Conducted on PT:


Ratio, Insulation Resistance, Winding Resistance.

Test Conducted on Transformer:


Voltage Ratio, Winding Resistance, Insulation Resistance, Magnetic core balance, Magnetizing
current, Vector Group, Tan Delta, SFRA, FDS, BDV, Stability Test.

Test Conducted on ACB/VCB:


Coil Resistance (closing, tripping, spring charge motor), Contact Resistance Measurement, Insulation
Resistance, Breaker Timing (c-o-co), HV test (VCB), Functional Test: Pick up current & voltage
( closing, tripping, spring charge motor)

Test conducted on HT/LT Motors:


Winding resistance, Inductance Measurement, IR, PI, TAN Delta and Stability Test.

Test Conducted on HT Board Bus Bar:


HV, IR, CRM
Cable Testing: IR, HV, VLF.
Testing of MCCB, OLR and ELCB.
Testing of relays of Transformer feeder, Motor feeder

PREVEOUS WORK EXPERIENCE:

SEPT 2015 OCT 2015 ESSAR OIL LTD., VADINAR

I have worked as an Electrical Engineer with Essar Oil Ltd., Jamnagar for Shutdown project.
Transformer maintenance
HV & LV Switchboards maintenance
HV Panel Maintenance
PMCC & MCC Maintenance
Lighting maintenance
Heat Tracing Maintenance

JAN 2015 APR 2015 SHELL GTL, QATAR

Recently I have worked as Supervisor at Qatar Shell GTL since January 2015. I have experience in
following fields.
Transformer maintenance
HV & LV Switchboards maintenance
HV Panel Maintenance
PMCC & MCC Maintenance,
Lighting maintenance
Heat Tracing Maintenance

AUG 2014 DEC2014 RELIANCE INDUSTRIES LTD.

I have worked as Maintenance engineer with Reliance Industries ltd., Hazira at Ethylene tank farm
2. I am having experience in

Transformer maintenance
Motor maintenance
6.6 KV HVS Panel Maintenance
PMCC & MCC Maintenance,
Condition Monitoring of HVS, LVS, Transformer, HT Motors, Battery Charger, UPS.
ACB & VCB Maintenance
MARCH 2014- MAY 2014 QCON, QATAR

I have worked with QATAR ENGINEERING & CONSTRUCTION COMPANY WLL at Qatar
Fuel Additives Company for shutdown maintenance job.
Awareness on Hazardous area classifications and selection of electrical equipment
Transformer maintenance
6.6 KV HVS Panel & Bus-bar Chamber Maintenance
PMCC & MCC Maintenance,
Condition Monitoring of HVS, LVS, Transformer, Battery Charger, UPS.
ACB & VCB Maintenance

DEC 2012 JAN 2014 SIBA , SENEGAL, WEST AFRICA

I have worked as Maintenance Engineer with SIBA steel, Dakar, Senegal. West Africa.
I was independently handling the Complete Galvanizing Plant complex including CTL &
Corrugation Lines.

JOB RESSPONSIBILITIES:
Designed and implemented special strategies related to maintenance procedures.
Performed routine maintenance inspections of equipment to identify and respond to
problems in a timely manner, thus preventing breakdowns.
Provided solutions and fixed equipment malfunctioning, system faults and network errors
Used root-cause-failure techniques, corrective actions, modifications and performed
replacements and/or new installation.
Assigned personnel and technical support teams to sites requiring 24/7 maintenance.
Worked with companys vendors and supervised subcontractors during various maintenance
projects to ensure proper completion of work performed at customers facilities.
Utilized different reliability and testing strategies in plants to maintain and improve operations
profitability.
Directed storage of equipment and assured safety measures were followed
Planning Preventive maintenance for the plants equipments and spares planning
I have worked with Siemens SINAMICS S 120, SINAMICS G120, MASTERDRIVE MC,
MICROMASTER 440 AC Drive.
I have worked with Siemens ( S7 300, S7 200) and OP 77A & OP 77B HMI.
I am also responsible to maintain Aquatherm, Compressor, ETP, WTP, Temperature &
Pressure Control Systems, EOT CRANES.
I am familiar with soft ware like SIMATIC MANAGER V 5.5, SIMOTION SCOUT V 4.2, WINCC
FLEXIBLE 2008 and DRIVE MONITOR.
FEB 2007 DEC 2012 STEELCO GUJARAT LIMITED

I have worked as Deputy Manager with STEELCO GUJARAT LTD. At Palej, Dist. Bharuch
since February 2007 to December 2012. Ours is a joint venture between COMCRAFT GROUP in
collaboration with HITACHI JAPAN. The company manufactures COLD ROLLED SHEETS and value
added products like Galvanized sheets and coils, corrugated sheets and OEM materials.

JOB RESSPONSIBILITIES:

Coordination with Consultant for the planning of Electrical Systems, Utilities and
machineries
Supervise and manage vendor engineering and equipments deliverable to ensure
compliance with project standards and specifications.
Reviewing and reporting of the project status.
Execution of the project engineering involving Installation, commissioning
Maintenance of electrical equipments such as
- HT switchgears consist of VCB breakers, PMCC/MCC, AC & DC Motors
-66/11 kV & 11/0.433 kV Power/Distribution Transformers.
-UPS, Battery charger, VFD with battery bank.
-Protection system include Microprocessor based relay, Numerical relay.
-DG Set & Plant Lighting.
Troubleshoots plant electrical problems to determine their cause and recommends options
for eliminating such problems. Includes carrying out tests on equipment.
Capable of guiding/leading the electrical maintenance team and implementing the best
maintenance strategy for the plant including High voltage of 66KV & 11 KV system.
Condition Monitoring and Predictive maintenance of critical equipment and corrective
actions to avoid breakdown.
Planning for resources and manpower for planned shutdown of the plant and execution
including start-up.
Daily Power monitoring, calculations and reporting at monthly basis.
Material procurement and maintaining minimum spares for attending breakdown and
reducing breakdown time.
Coordination with various departments for smooth functioning of the equipment by
feedback and suggestions from them.
ISO documentation, Quality Circle formation for detecting problems and solving from shop
floor employees.
We are having different lines as mentioned below:
6 HI & 4 HI COLD ROLLING MILL
PICKLING LINE
ELETREOYTE CLEANING LINE
GAS & DIESEL ANNEALING FURNACE
REWINDING & SLITTING LINES
CORRUGATION MACHINES
CUT TO LENGTH MACHINE
CONTINUOUS GALVANIZING LINE
ROLL GRINDING MACHINE

October2004 - April2006 GAIL INDIA LTD., Gandhar, Bharuch

Motor maintenance
Transformer maintenance
6.6 KV HVS Panel & Bus-bar Chamber Maintenance
PMCC & MCC Maintenance,
Condition Monitoring of HVS, LVS, Transformer, HT Motors, Battery Charger, UPS.
ACB & VCB Maintenance
Battery maintenance
I have worked in LPG, SBP, and PENTANE Plant

Dec.1997 - Dec.1999 RELIANCE INDUSTRIES LTD., HAZIRA

Motor maintenance, MCC, PCC, HVS, TRANSFORMER maintenance.


Breakdown & Preventive maintenance jobs.
I have worked in Substation 6.6/.430 kv.

HAVING KNOWLEDGE OF :

ELECT SAFETY RULES & ELECT SAFETY PROCEDURES


ATEX DIRECTIVES
HAZARDOUS AREA CLASSIFICATION
RISK ASSESSMENT MATRIX
PTW DOCUMENTATION
JOB HAZARD ANALYSIS
METHOD STATEMENT
STANDARD CONTROL SHEET
SLD, EPTW, LOA & SFT

TRAININGS ATTENDED:

HSE INDUCTION
FALLING OBJECT PROTECTION
HAND TOOLS & POWER TOOLS
LIFE SAVING RULES AT JOB SITE
BARRICADES AND SIGN
CONFINE SPACE ENTRY
FIRE PREVENTION & PROTECTION
PERSONAL PROTECTIVE EQUIPMENTS
MANUAL MATERIAL HANDLING
HAZARDOUS WORK PERMIT
LOCK-OUT / TAG-OUT PERMIT
FIRST AID AND INJURY REPORTING
PERMIT TO START WORK
WORK AT HEIGHT TRAINING

PERSONAL PROFILE:

AGE 38 YEARS

GENDER MALE

LANGUAGES KNOWN ENGLISH,HINDI,GUJARATI

HOBBIES AUTOMISATION, INTERNET, LISTNING MUSIC

PASSPORT DETAILS NO: H9478458

EXPIRY DATE: 14/01/2020

Hareshkumar D. Chauhan

You might also like