Professional Documents
Culture Documents
Franklin Tester FT 510
Franklin Tester FT 510
Franklin Tester FT 510
1,4
1,2
0,8
0,6
0,4
0,2
H(A/m) H(A/m)
-1000
1000 -500 500 1000
-0,2
-0,4
-0,6
-0,8
-1
-1,2
-1,4
J(T) -1,6
Determination of surface resistance of individual samples of electrical steel and Measuring categories
punched parts
Surface resistance
Quality control of insulation coating resistance distribution
Manual or fully automatic version
Preparation and execution of the measuring process according to
ASTM-Standard A 717-01 and IEC 60404-11
The test head consists of two longitudinal rows of five vertically mounted steel rods
which are free to move axially against the surrounding spiral springs. A stainless steel Manual version
measuring contact is positioned at each end of each rod. It is possible to move the test
head hydraulically perpendicular to a surface.
The testing contacts are pressed onto the insulation coating with a pressure of 129N
per electrode. An electrical contact to the steel sheet is created with a spiral drill. If the
resistance is finite a current inversely proportional to the resistance flows through the
insulation coating.
Fully automatic measurement including comprehensive monitoring via FMA Expert soft-
ware and integration into quality management systems, configuration of measuring station
and customer-specific software.
Technical Data
Testing voltage 0.5V, 0.1mV resolution
Accuracy of settings better than 0.5%
System accuracy better than 0.5% Double-sided measurement
Measuring unit for hydraulic pressure 0 to 40bar 1%
Hydraulic cylinder length of stroke: 15.3cm
cylinder surface: 14cm
force: 550bar
Test head electr. contact: 10 contact pins
total area: 6.45cm 0.5%
Maximum testing pressure 25bar (displayed value, optional 40bar)
Weight (manual version) voltage supply unit approx. 9kg
device and pump approx. 44kg
Inline measuring system
Supply voltage 220V AC, 50/60Hz