Difference Between Pipes and Tubes

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 1

The difference between pipes and tubes is simply in the way it is sized.

PVC pipe for plumbing


applications and galvanized steel pipe for instance, are measured in IPS (iron pipe size). Copper
tube, CPVC, PeX and other tubing is measured nominally, which is basically an average diameter.
These sizing schemes allow for universal adaptation of transitional fittings. For instance, 1/2" PeX
tubing is the same size as 1/2" copper tubing. 1/2" PVC on the other hand is not the same size as
1/2" tubing, and therefore requires either a threaded male or female adapter to connect them. When
used in agricultural irrigation, the singular form "pipe" is often used as a plural. [17]
Pipe is available in rigid "joints", which come in various lengths depending on the material. Tubing, in
particular copper, comes in rigid hard tempered "joints" or soft tempered (annealed) rolls. PeX and
CPVC tubing also comes in rigid "joints" or flexible rolls. The temper of the copper, that is whether it
is a rigid "joint" or flexible roll, does not affect the sizing. [17]
The thicknesses of the water pipe and tube walls can vary. Pipe wall thickness is denoted by various
schedules or for large bore polyethylene pipe in the UK by the Standard Dimension Ratio (SDR),
defined as the ratio of the pipe diameter to its wall thickness. Pipe wall thickness increases with
schedule, and is available in schedules 20, 40, 80, and higher in special cases. The schedule is
largely determined by the operating pressure of the system, with higher pressures commanding
greater thickness. Copper tubing is available in four wall thicknesses: type DWV (thinnest wall; only
allowed as drain pipe per UPC), type 'M' (thin; typically only allowed as drain pipe by IPC code), type
'L' (thicker, standard duty for water lines and water service), and type 'K' (thickest, typically used
underground between the main and the meter). Because piping and tubing are commodities, having
a greater wall thickness implies higher initial cost. Thicker walled pipe generally implies greater
durability and higher pressure tolerances.
Wall thickness does not affect pipe or tubing size.[18] 1/2" L copper has the same outer diameter as
1/2" K or M copper. The same applies to pipe schedules. As a result, a slight increase in pressure
losses is realized due to a decrease in flowpath as wall thickness is increased. In other words, 1 foot
of 1/2" L copper has slightly less volume than 1 foot of 1/2 M copper.[citation needed]

You might also like