DISPLAY VARIABLES VALID KEY PRESSES

Flow Rates and Totalizers


Batch Totalizers are displayed by including the [Batch] key before the key presses
shown below:

Daily & Cumulative Uncorrected Gross (IV) [Gross] or [Gross] [Meter] [n]
Batch Uncorrected Gross (IV) [Batch] [Gross] or [Batch] [Gross] [Meter] [n]
Daily & Cumulative Corrected Net (GSV) [Net] or [Net] [Meter] [n]
Daily & Cumul. S&W Corrected Net (NSV)
Batch Corrected Net [Batch] [Net] or [Batch] [Net] [Meter] [n]
Batch S&W Corrected Net (NSV)
Daily & Cumulative Mass [Mass] or [Mass] [Meter] [n]
Batch Mass [Batch] [Mass] or [Batch] [Mass] [Meter] [n]
Daily & Cumulative Energy [Energy] or [Energy] [Meter] [n]
Total @ Second Reference Temperature

Current Instantaneous Values


Batch Totalizers are displayed by including the [Batch] key before the key presses
shown below:

Meter Temperatures [Temp] or [Temp] [Meter] [n]


Meter Pressures [Press] or [Press] [Meter] [n]
Density [Density] or [Density] [Meter] [n]
Unfactored Density [Density] [Meter] [n]
API Gravity & API @ Reference [SG/API] or [SG/API] [Meter] [n]
Specific Gravity & SG @ Reference [SG/API] or [SG/API] [Meter] [n]
Densitometer Temperatures [Density] [Temp] or [Density] [Temp] [Meter] [n]
Densitometer Pressures [Density] [Press] or [Density] [Press] [Meter] [n]
Prover Temperatures [Prove] [Temp]
Prove Pressures & Plenum Pressure [Prove] [Press]
Prover Density [Prove] [Density]
Prover Density Temperature [Prove] [Density] [Temp]
Prover Density Pressure [Prove] [Density] [Press]

Calculation Factors
Batch Totalizers are displayed by including the [Batch] key before the key presses
shown below.

Volume Correction Factors (VCF) [Temp] [Factor] or [Temp] [Factor] [Meter] [n]
Pressure Correction Factors (Cpl) [Press] [Factor] or [Press] [Factor] [Meter] [n]
Batch FWA Meter Factors [Batch] [Meter] [n] [Factor]

Other Factors and Intermediate Calculation factors

Meter Factors & K Factors [Factor] or [Meter] [n] [Factor]


Pycnometer Factors [Density] [Factor] or [Density][Factor] [Meter] [n]
Solartron / Sarasota / UGC Factors [Density] [Factor] or [Density][Factor] [Meter] [n]
Equilibrium Pressure / A, B & F Factors [Press] [Factor] [Meter] [n]
Linearizing Factor / Daily FWA LCF [Factor]
Alarm Information
Active Alarms [Alarms]
Transducer High/Low Alarm Limits [Meter] or [Meter] [n]

Product Information
Product Number and Name
Override API & SG Gravity
Meter Factors Calculation Mode
[Product] or [Product] [n]
Note: n = 1-16

Prover Sequence Information


Prove Counts & Run Number
Meter Selected to Prove
Current Prover Status
Tdvol & Tdfmp Timers [Counts] or [Prove] [Counts]

Batch Schedule Stack & Presets


Batch ID Character String
Running Product Number [Batch] [Setup] or [Meter] [n] [Batch] [Setup]
Batch Preset Counters &
Interface Due Line Pack Counter [Batch] [Preset] or [Meter] [n] [Batch] [Preset]

Miscellaneous Displays
Current Time & Date
Power Last Applied Time & Date
Power Last Lost Time & Date
Task Timing Display [Time]
Display of Raw Input Signals [Input]
Display of Raw Output Signals [Output] [Status]
Hardware Inventory / Software Version [Status]
Honeywell Module Status [Input] [Status]