1. With neat diagram, explain the principle of operation of Amplitude Modulation. Derive its
power relations. (16)
2. (a)Explain satellite communication system with suitable diagram (12)
(b) what is satellite communication(4)
3. What is a Zener diode? Explain the operation of Zener diode and draw its characteristics.(16)
4. Explain the operation of half wave rectifier with neat sketch and derive the necessary
expression. (16)
5. Explain the working of the CB configuration of a BJT.
Prepared By Verified by
ARUNAI COLLEGE OF ENGINEERING
VELU NAGAR, MATHUR,
TIRUVANNAMALAI 606 603
Prepared By Verified by
ARUNAI COLLEGE OF ENGINEERING
VELU NAGAR, MATHUR,
TIRUVANNAMALAI 606 603
Prepared By Verified by
ARUNAI COLLEGE OF ENGINEERING
VELU NAGAR, MATHUR,
TIRUVANNAMALAI 606 603
11. Derive output equation of a three phase induction motor and point out salient features of this
equation.(16)
12. Compute the main dimensions of the core of a 5 KVA, 11000/400 volts, 50Hz single phase core type
transformer. Window space factor = 0.2; The height of the window is 3 times its width; Current density
= 1.4 A/mm2; Bmax = 1.0 Tesla; Stacking factor = 0.9; Net conductor area in the window = 0.6 times
the net cross sectional area of iron in the core. Assume square cross-section for the core. .(16)
13. Derive output equation of a single phase transformer and point out salient features of this equation.(16)
14. Design the suitable number of cooling tubes necessary for a 3 phase transformer having the following
particulars: KVA rating = 1250, tank dimensions = 0.65 1.55 1.85 m, full load loss = 13.1 kW, loss
dissipation due to radiations = 6 W/m2-C, loss dissipation due to convection = 6.5 W/m2-C ,
improvement in convection due to provision of tubes = 40%, temperature rise = 40C, length of each
tube = 1 m, diameter of tube = 50 mm. Neglect the top and bottom surface of the tank as regards the
cooling. .(16)
15. Determine the dimensions of the core, the number of turns, the cross-section area of conductors in
primary and secondary windings of a 100 KVA, 2200 / 480V, single phase, core type transformer to
operate at a frequency of 50Hz, by assuming the following data. Approximate volt/turn = 7.5 V.
max.flux density = 1.2 Wb/m2. Ratio of effective cross-sectional area of core to square of diameter of
circumscribing circle is 0.6. Ratio of height to width of window is 2. Window space factor = 0.28,
current density = 2.5 A/mm2. .(16)