Al Good Alternative To Steel For Fixed Roof Tanks Oil Gas Journal PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Aluminumagoodalternativetosteelfor
fixedrooftanks
05/18/1998

ALUMINUMTANKCOMPONENTS1
PhilipE.Myers
ChevronProductsCo.
SanRamon,Calif.

GeorgeL.Morovich
Tank&EnvironmentalTechnologiesInc.
TheWoodlands,Tex.

EarlJ.Crochet
PlantationPipeLineCo.
Atlanta

Aluminumdomesmaximizeusabletankcapacity,avoidcoatingcosts,andavoidcolumn
problems.PhotocourtesyofTemcor(Fig.1[7,768bytes]).

Aluminum,usedformajorabovegroundstoragetank(AST)components,hasadvantagesand
disadvantageswhencomparedtotheconventionalsteelmaterialsofconstruction.

Forfixedrooftanks,refinerscansavemoneyandgainimprovedqualityiftheyconsidertheadvantagesof
aluminumoversteel.

Thisarticleisthefirstofatwopartseriesthatdiscussestheuseofaluminumstructuralcomponentsfor
ASTs.Thefirstarticlepresentsacomparisonofcoveredtanksvs.uncoveredtanks(tankswithafloating

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 1/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

roofbutnofixedroof)aswellasacomparisonofaluminumdomeroofs(ADRs)vs.steelconeroofs
(SCRs).Thesecondarticlecomparesvarioustypesofaluminumandsteelinternalfloatingroofs.

ForlargeASTs,fixedroofsshouldbealuminumbecausetheroofsupportcolumnscanbeeliminatedwhen
usingaluminumdomes(Fig.1[7,768bytes]).LargeSCRsrequirecolumns.Aluminumdomesmaximize
tankcapacity,reducecoatingcosts,andhavefiresafetyadvantages.

Forinternalfloatingroofs,aluminumandsteeleachhasitsownmerits.Insteadofjustbidprices,tank
managersandoperatorsshouldconsiderthelongtermoperational,safety,environmental,andeconomic
issuesofaluminumandsteelcomponentsinASTs.

AlthoughAPI650definesaminimumstandardofquality,insomecases,whensafetyandtotalcostof
ownershipareconsidered,thestandardmaynotbeadequatefordesiredlongtermperformance.

Coveredvs.uncoveredtanks
AnASTthatincludesafloatingroofandiscoveredbyafixedroofisconsideredaninternal
floatingrooftank(IFRT).Anexistingexternalfloatingrooftank(EFRT)canbeconvertedtoa
coveredIFRTbyretrofittingitwithafixedrooforcover.

AlthoughtheEFRTmayhavealowerinitialcostthantheIFRT,itmaynothavethelowesttotalownership
costwhenlongtermoperatingcosts,maintenancecosts,andpotentialrisksareconsidered.Thefactors
whichfavorbuildingorretrofittingEFRTswithfixedroofsareincidentprevention,environmentalprotection,
safety,andreducedlongtermmaintenanceandoperatingcosts.

Table1[25,417bytes]summarizestheconsiderationsfortheuseofcoveredtanks(IFRTs)vs.uncovered
tanks(EFRTs).

Overloadingexternalfloatingroofs
Externalfloatingroofsarevulnerabletooverloading.Thefixedroofeliminatestheintrusionof
rainwater,snow,ice,anddirtintothetank.

InEFRTs,precipitationcansinkthefloatingroofsduringheavyrainfallsorprolongedwinterstorms.
Historically,severalexternalfloatingroofssinkeachyearintheU.S.duringthewinterorasaresultof
extremerainfallevents.Thisnumbermaybeunderestimatedbecausetheseincidentsarenotrequiredto
bereportedthroughanypublicchannels.

Snow,ice,dirt,anddebrisaccumulationcanrenderthedrainsinoperable,resultinginoverloading.
Overloadingcanresultwhendrainsystemsfreezecloseorwhendraincapacitiesareinadequate.

Inaddition,heavysnowfallcanresultinanunbalancedloadconditionifthesnowcollectsonthewindward
andshadedsurfaces.IntheMiddleEast,whererainwater,snow,andicearenotaconcern,someusers
requireIFRTstoavoidaccumulationsofwindblownsand.

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 2/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Externalfloatingroofsareespeciallyvulnerabletooverloadingwhentheproductlevelisloworwhilethe
floatingroofislandedonitssupports.Thereareseveralreasonsforthis:

PerAPI650AppendixC.3.4,thedesignbuoyancyisbasedonsupporting10in.of
rainwater(or52psf)however,thesupportsareonlydesignedtosupport25psf,perAPI
650AppendixC.3.10.2.

Whentheroofisfloatingatalowelevation,theheadpressureforcingrainwaterthroughthe
drainsisreduced.Thisheadreductionincreasestheamountandweightofwateronthe
deckduringrainfall.

Inanannularpontoonfloatingroof(flatcenterdeck),thecenterdeckishighlyflexibleand
willrisewhenvaporsevaporateasthedeckisheatedbysolarenergy.Thedeckalso
deflectsdownwardatthecenterasitisloadedwithwater.Whentheroofisfloatingnearthe
bottom,loadedwithwaterandsaggingatthecenter,thecenterdecksupportscancontact
thebottomandfailasaresultofbeingoverloaded.Thefloatingroofsupportshavealso
beenknowntopuncturethebottom,resultinginseriousleaks.

ThedrainsizesoftheexternalfloatingroofsidentifiedinAPI650AppendixC3.8,are
minimal.Thepurchasershouldunderstandandidentifythedrainrequirementsforeach
location,basedonanticipatedrainfall.

Waterintrusion
Thecoveredtankminimizesrainwaterentryintothetank.

Rainwatercanintrudeintothetankstockbyseepingpasttheseals.Waterwillmixwithorleachout
certainadditivesorcomponents,whichmaycompromiseproductquality.Inaddition,contaminatedwater
bottomsrequirethelongtermcostofcollectionanddisposalasahazardouswaste.

Anotherproblemassociatedwithwaterentryintothetankhastodowithmethyltertiarybutylether(MTBE)
andotheretheroralcoholbasedadditives,whicharecommonlyusedasagasolineadditivetomeet
requirementsoftheCleanAirAct.

BecauseMTBEandalcoholarepreferentiallysolubleinwater,remediationismorecomplexforthemthan
forhydrocarbonstherefore,itisimportanttominimizeanyintroductionofwaterintoatankstoring
oxygenatedgasoline.

EliminationofEFRTdrains
Bycoveringatank,theneedforanEFRTrainwaterdrainiseliminated.Theremovalofthedrain
avoidstheriskofdrainlinefailure,reducestheinitialtankequipmentcost,andresultsin

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 3/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

significantlongtermoperationalandmaintenancesavings.Fig.2[30,075bytes]showshowthe
drainisattachedtotheEFRT.

Thedrainremovalisenvironmentallydesirablebecausethepotentialforamajorspillorreleaseasaresult
ofaroofdrainfailureiseliminated.Asubstantialspillmayoccuriftheroofdrainrupturesandthevalveon
theroofdrainhasbeenleftopen.

ManycompaniesrequireEFRTdrainvalvestobekeptclosed.Thispolicy,however,increasestheriskof
overloadingthefloatingroofbecauseitrequiresmanualinterventiontodrainthefloatingroofduringrainfall.
Somecompanieshaveinstalledhydrocarbonsensingvalvesandotherdetectiondevicesontheroofdrain
outletshowever,thesedeviceshavenotproveneffectivetopreventthereleaseofhydrocarbonsthrough
adamagedroofdrainlineunderallconditions.

Inthelongterm,avoidanceofmaintenancecostsstemsfromeliminatingthemanualdrainoperation.
Maintenancecanbeannualcoldclimateprotectionoreventualdrainlinereplacement.Topreventdrain
systemdamageduringprolongedwinterconditions,externalfloatingroofdrainsareoftenfilledwith
antifreeze,whichintroducesanadditionalhazardouswastehandlingandtreatmentcost.

Increasedusabletankcapacity
Forcoveredfloatingrooftanks(convertedfromanEFRT)andforIFRTs,federalregulationsdo
notrequireasecondaryseal.Theeliminationofthesecondarysealreducestheinitialtank
equipmentcostandassociatedlongtermmaintenanceandinspectioncosts.Perhapsmost
important,itincreasestheusablecapacity(orworkingvolume)ofthetank.

BecauseonlyasingleliquidmountedprimarysealisrequiredforanIFRT,floatingroofscanbeoperated
atahigherlevel,closertothefixedroofwithoutinterferencefromthesecondaryseal.

ThecapacitysavingsfromeliminatingtheEFRTweathershieldtypesecondarysealcanbeintherangeof
2436in.however,eliminatingasecondarysealfromaninternalfloatingroofwillsaveonly812in.For
newconstruction,thelowerdesignloadingofAPI650AppendixH(InternalFloatingRoof),willfurther
reduceouterrimprofileclearancerequirementsbyanadditional1024in.dependingonthetypeof
internalfloatingroof.

Corrosion
Externalfloatingroofscorrodeandmustbemaintainedbyinitialandperiodicrecoating.Costsfor
recoatingoldtankswithleadbasedpaintscanbesignificant.Bycoveringthetank,theneedto
coatthefloatingroofiseliminated.Eveniftheexternalfloatingroofisdueforacoatingremoval
andpaintjob,itisnotnecessaryifthetankiscovered.

Theseverityofinternalshellcorrosionisnormallyreducedbycoveringthetank.Fortankswhicharefully
coatedontheinternalshell,thelifeofthecoatingwillbeincreasedasaresultofthereducedweather
effects.

Safetyandsecurity
http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 4/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

FixedaluminumdomeandsteelroofsarelesslikelythanEFRTstocausefireandaccess
problems.

Becauseaninternalfloatingroofiswithinaclosedconductivestructure,the"FaradayCageEffect,"which
isolatestheinteriorfromtheeffectsofexternalelectricaleventssuchaslightningstrikesorstaticcharges,
reducestheriskoffire.Evendirectlightningstrikeswillnotcausesparkstodischargefromthefloating
rooftothetankshell.

Firesorexplosionsinvolvinginternalfloatingrooffiresarehundredsoftimeslesslikelythanthose
involvinguncoveredEFRTs.ExistingEFRTshavealsobeencoveredsimplyasaresultoftheirproximity
toanignitionsource(suchasaflarestack).Despiteincreasedpotential,rimfiresonEFRTsareusually
quicklyextinguished.

Afixedroofcontrolsaccesstothehazardousor"confinedspace"environmentinthetank.TheU.S.
OccupationalSafetyandHealthAdministration(OSHA)requiresthateachfacilitydesignatethoseareas
thatareconfinedspaces,andentrymustmeetallrequirementsunderOSHA29CFR1910.146.Typically,
forpetroleumstoragetanks,thespacewithintheshellofanEFRTisconsideredaconfinedspaceifthe
roofisbelow5ftoftherim.ForanIFRT,however,anyspacewithintheshellorunderthefixedroofis
alwaysconsideredaconfinedspace.

ManyEFRTsinremoteareashavebeencoveredduetoconcernsofunauthorizedaccess.Inonecase,
childrenwerefoundridingtheirbicyclesonthedeckofa200ftdiameterEFRTslatedforgasolineadditive
(MTBE)servicespentbottlerocketswerealsofoundonthatsamedeck.

Inthe1980s,theU.S.AirForceStrategicAirCommandbeganaprogramtocoverexistingEFRTs,
primarilytoeliminatewaterproblemswithjetfuelandantifreezeadditives.Asidebenefitofcoverswasto
concealbasefuelinventorylevelsfromaerialsurveillance.

Steelconeroofsvs.aluminumdomeroofs
ClearspanADRtankshavemoreadvantagesthandocolumnsupportedSCRtanks.Table2
[54,246bytes]comparesADRsandSCRs.

TheADRisusuallythemostfavorableoptionfortheretrofitofanexistingEFRTwithanewfixedroof.For
newtankconstruction,orreplacementofanexistingconeroof,anevaluationshouldconsidertheinitialbid
priceaswellasotherfundamentalvariables:

Operatingcapacitysavings
Initialcoatingcostandlongtermmaintenance
Theeliminationofcolumnsandtheirrelatedproblems:emissions,penetrationseal,bottom
corrosion,maintenanceobstruction,settlement,andincidentriskcosts.

Steel,selfsupporteddomerooftanksandsmalldiametertankswithselfsupportedfixedroofs
areexcludedfromthisevaluationtheyshare,however,manyofthebenefitsofADRtanks.

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 5/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Similarities
Functionally,therolesoftheADRsandtheSCRsaresimilar:

Bothtypesprotectthefloatingrooffromenvironmentalloading.
Bothtypesminimizedirtandwaterentryintothetank.
Bothtypeseliminatetheintrusionofrainwaterintothetankhowever,thequalityofthe
aluminumdomeweathertightdesignwillvarybymanufacturer.Itiscriticaltospecifya
provenADRdesignwhichisleaktight.
Bothtypesreduceweatherrelatedcorrosionontheinternalshellsurfaces.
Bothtypeseliminatethewindrelatedcomponentoftankemissions.
Bothtypesimprovefireprevention,improvesafety,andenhancesecurity.

Costeffectiveness
Technically,theADRsandSCRshavedifferentrequirements.WhenretrofittinganexistingEFRT
withanewfixedroof,theconversiontoanADRtankisusuallythemostcosteffective,regardless
oftanksize.Thisconversiondoesnotrequireremovalfromservice,tankcleaning,orextensive
downtimeforhotwork.

Thealuminumdomeisaboltedstructurethatcanbeassembledonthetankwithnohotwork.Steelroofs
requirehotworkbecausetheyarefieldweldedtherefore,thehazardsincreaseforsteelconstruction.

Today,newSCRconstructionshouldminimizethenumberofSCRsupportcolumnstoavoidpenetrations
oftheinternalfloatingroofandtheirrelatedinitialcosts,increasedemissions,andcolumnseal
replacementcosts.

Withoutconsideringotherinitialandlongtermcostfactors(listedbelow),thealuminumdomeusually
becomescosteffectivefortankdiametersof40mormore,thediameterforwhichmultipleringsof
columnswouldberequiredforanSCR.Thealuminumdomeroofiscosteffectivefortankslargerthan20
mwhencomparedtoasteeldomeroofandlargerthan10mifinternalcoatingsareneededforsteel.

Capacity
ThecapacityofanSCRisreducedbecausetheconeroofsupportstructure(includingroofrafter
toshellattachmentgussets)extends1218in.belowthetopofthetankshell,andthefloating
roofsealmayrunintothefixedsteelroof.Althoughthetankshellcouldbeextendedupward,this
istypicallynotpracticalorcosteffectiveforaprojecttocoveranEFRT.TheADRtankdoesnot
usuallyrestrictcapacitybecausetheattachmentofexternalframingpermitsfulltraveloftheseal
tothetopofthetankshell.

Analysesshouldalwaysbeperformedtoconfirmclearancewithotherdeckobstructions(e.g.,foamdams
andpressure/vacuumvent).Largerdiameterdomeshaveasteepriseattheperiphery,whichhelpsavoid
interiordeckobstructions.Foradditionalclearance,thealuminumdomecanbeinstalledwithaskirt,which
effectivelyraisesitsbaseelevation.
http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 6/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Coatings
Whencomparingthedifferencesbetweensteelandaluminum,itisimportanttoconsiderthe
rathersubstantialcostsofsurfacepreparationandcoating.Aluminumdomesaretypicallynot
coated,whereassteelroofsarealwayscoatedexternallyandoftencoatedinternallyincorrosive
environments.

ADRsarejustifiedfortankswithdiametersassmallas10mfortankswhichrequireinternalcoatings.This
conclusionisbasedonconsiderationofthecoatingcost,thespecialconstructiondetailrequirements,the
internalsealweldingrequirement,andtheextensivepreparationrequiredforaneffectiveinternalcoating.
Inaddition,coatingshavemaintenancecostsandrecoatingchargesasaresultofnormalwear.

BeyondtheinitialroofcoatingcostonanSCR,thereisthefuturemaintenance.Ofalltheexternallycoated
surfacesonatypicaltank,theconeroofcoatingwillfailfirstasaresultofhorizontalexposuretosunlight
andpondingofrainwater.Thesefactorsresultinruststreaksthatrundownthetankshellandcreatea
cosmeticproblem.

TheuseofanADRextendsthetimeintervalbetweentankshellrecoatingandeliminatesthecostof
recoatingtheroofsurfacearea.

Steelroofsoftenhaveuncoatedinternalsurfaces.Theseroofscanproducetonsofcorrosionproducts
thateventuallydelaminatefromtheundersideofthefixedroofandcollectonthebottomofatank.Inone
case,anestimated70tonsofcorrosionproductswereremovedfromthebottomofa280ftdiameterSCR
tankincrudeoilservice.

Hadaninternalfloatingroofbeenused,theexposureofthefixedrooftocorrosivesulfurcompounds
wouldhavebeenminimized.Preventivemaintenance,however,wouldstillhavebeenrequiredtoremove
somecorrosionproductsfromthedeck.TheADRwouldnothavegeneratedcorrosionproducts.

Emissions
TheemissionoforganicorhazardousvaporsfromanADRislowerthanthatofasimilarSCR.
Unliketheconeroof,thedomeisafreespanstructure.TheSCRtankhascolumnsthatextend
fromthefixedroof,throughthefloatingroof,andtothetankbottom.TheSCRhasoneormore
columnpenetrationsfromwhichemissionsescapetotheatmosphere.Theuseofanaluminum
domereducesthetotalfacilitiesemissionsinventorybyavoidingtheemissionfactorsforcolumn
penetrations.

Fig.3[36,080bytes]illustratesthedifferencesbetweentheADRandSCRtanks.

Chapter19,EvaporativeLossMeasurement,oftheAPIManualofPetroleumMeasurementStandards
providesabasisfortheEPAemissionscalculationprogram.Althoughnotcurrentlypartoftheemission
calculationformula,theAPICommitteeonPetroleumMeasurementisconsideringbetterdefiningthe
variablesthatinfluencebulkandsurfaceliquidtemperaturestoimproveaccuracy.Forexample,although

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 7/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

bulktemperatureiscurrentlybasedonambientairconditions,themethodofdeliveryandturnoverrates
aremoreinfluentialindeterminingthebulktemperature.

Currently,thereisonlyageneral"paintfactor"toadjustbulktemperatureforroofvariables.External
floatingroofsexposedtodirectsunlightshouldhavehighersurfaceliquid,shellsurface,anddeckfitting
temperaturesthancoveredfloatingroofs.Currentbulktemperaturecalculations,however,donotinclude
thesesolarradiationeffects.

Althoughnotcurrentlyconsideredintheemissionscalculation,thetypeofmaterialusedinthetankshould
alsobeconsidered.Becausealuminumhashigherreflectiveandloweremissivepropertiesthansteel,
emissioncalculationsshouldincludethefollowingvariables:

AdjustmentofliquidsurfacetemperaturetoreflecttheimpactofheatedshellandEFRT
surfaces.
Additionofsolarimpactandmaterialvariablestoreflectreducedinternalsurface
temperaturesbyeitherasteeloraluminumfixedroof.
Additionofsolarimpactandmaterialvariablestoreflectreducedsurfaceliquid
temperaturesbyusingvarioustypesofaluminuminternalfloatingroofs.

Corrosioncausedbycolumns
Roofsupportcolumnsincreasethepotentialfortankbottomcorrosionandroofcorrosion.

APIstandardsdonotallowcolumnstobeattachedtothetankbottomsothatthetankbottomcansettle
withoutdistortingtheroof.Themovementofthecolumnbaseonthetankbottomerodesanycoatingon
thetankbottomandcreatesconditionsconducivetocrevicecorrosion.

Corrosiondamagethatoccursnearorunderthecolumnbasesisrarelyinspected(evenduringformalAPI
653internalinspections)becausethebaseplatecoversthecorrosiondamage.Columnguidesandbase
plates,weldedtothetankbottom,makecoatingsurfacepreparationandapplicationdifficult,which
increasesthepotentialforcorrosionattack.

BecausethereisahigherprobabilityoftankbottomleaksasaresultofcorrosioninSCRtanks,the
potentialforresultingenvironmentalcontaminationincreases.

Also,iftheSCRsupportcolumnsverticallysettle,theconeroofsurfaceplateswilldeflectdownwardand
pondwater(acceleratingcorrosion).Aclearspanaluminumdomeissupportedbythetankshell,and
uniformshellsettlementcanbefacilitatedbytheuseofaconcreteringwallfoundationdesign.

Morecolumnproblems
Columnscancauseproblemsiftheyareoutofplumb,traphydrocarbons,orareimproperly
jackedduringmaintenance.

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 8/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Columnswhichareoutofplumbwitheachotherandthetankshellcancausethecolumnpenetration
sealstowear.Inseverecases,floatingroofshavehunguponcolumnsastheproductlevelrose.

Closedshapedcolumns,suchaspipecolumns,canholdtrappedhydrocarbonseveniftheyaredesigned
tobeselfdraining.Manyfiresandexplosionshavebeeninitiatedbytrappedhydrocarbonsinroofcolumns
duringinternaltankwork.

Tankcolumnsareoftenjackedupwhennewtankbottomsarebeinginstalledorduringmaintenance.
Columnsandjackingstructurescancollapseifimproperlyjacked.Thealuminumdome,becauseithasno
columns,isnotaffectedbyinteriorbottomsettlementandoffersnoobstructiontobottominspectionor
maintenance.

Rooffrangibility
API650providesrulesfordesigningafrangiblerooffornewCRTs.Ifatankisinternally
overpressurized,afrangibleroofwillfailattherooftoshelljointandventtheexcesspressure
harmlesslytotheatmosphere.

Insomeinstances,theshelltobottomjointhasfailedwhileoverpressuringoroverfillingtankswithout
frangibleroofs.Thisfailurecausesthetanktorocketupward,spillingflammablecontentsorreleasing
liquids.Frangiblerooffailureshistoricallyhavenotreleasedliquidandhaveresultedonlyinrelativelyminor
damagetothetank.

API650AppendixG,whichcoversthedesignandconstructionofADRtanks,statesthattherooftoshell
jointisnotconsideredfrangible.Certainly,thestructuralattachmentsarenotdesignedtobefrangible.

ForallreportedADRoverpressurizationincidentstodate(lessthansix),however,theperipheralflashing
hasbehavedasifitwereafrangiblecomponent.EvenonADRtankslessthan40ftindiameter,inwhich
frangiblejointsarenotconsideredreliableforSCRtanks,theflashinghasbehavedasafrangible
component.

TheventareaofthealuminumdomeflashingshouldexceedtheventarearequiredunderAPI2000,
Section2.4.3.2,whichcoversemergencyandnormalventingfor"TanksWithoutWeakRooftoShell
Attachment."ThereisanopenAPIagendaitemtoallowthealuminumdomemanufacturertodocumentthe
frangibilityofapanelcomponentandallowthedocumentedcomponenttocontributetotheventareaas
requiredbyAPI2000.

Componentfrangibilityisnotthesameasafrangiblerooftoshelljoint,whichisdefinedunderAPI650,
Section3.10.2.5andAPI2000,Section2.4.3.1.Componentfrangibilityiscategorizedseparatelyunder
API2000.

Safetyaccess
IntherareeventofafirewithinanIFRT,thealuminumdomepanelsprovidegoodaccesstothe
firesurfaceforextinguishing.Thepanelswillmeltawayorallowanaxtopenetratethesurface.

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 9/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

Inoneincidentconcerningatankwithanaluminumroof,duringafirestartedbyweldingadjacent
toawastewaterbasin,thepanelsquicklymeltedawayallowingthefiretobepromptly
extinguished.

ThissameabilitytoremoveADRpanelsfacilitatesaccesstothetankinteriorintheeventthatpersonnel
withinthetankrequireemergencyverticalretrieval.

Bibliography
AluminumDesignManual:SpecificationsforAluminumStructures,theAluminumAsssociation,
Washington,D.C.
APIManualofPetroleumMeasurementStandardsChapter19,EvaporativeLossMeasurement,
AmericanPetroleumInstitute,Washington,D.C.
APIPublication2026SafeAccess/EgressInvolvingFloatingRoofTanksinService,American
PetroleumInstitute,Washington,D.C.
APIStandard2000VentingAtmosphericandLowPressureStorageTanks:Nonrefrigeratedand
Refrigerated,AmericanPetroleumInstitute,Washington,D.C.
APIStandard650WeldedSteelTanksforOilStorage,NinthEdition,1993,AmericanPetroleum
Institute,Washington,D.C.
Barrett,A.E.,"Geodesicdometankroofcutswatercontamination,vaporlosses,"OGJ,July10,
1989,p.90.
EPA40CFR60U.S.EPANewSourcePerformanceStandards(SubpartKb),40Codeof
FederalRegulations,Washington,D.C.
Myers,PhilipE.,AbovegroundStorageTanks,McGrawHill,NewYork,ISBN007044272X.
OSHA29CFR1910U.S.OccupationalSafetyandHealthAdministration,29CodeofFederal
Regulations,Washington,D.C.
TheAuthors

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 10/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

PhilipE.MyersisaseniorstandardsengineeratChevronProductsCo.Hehashadexperience
inprocessandprojectengineeringintheutility,chemicals,petrochemicals,andrefining
businesses.Inrecentyearshehasspecializedintanksandpressurevesseltechnology.Myers
servesaschairmanofthesubcommitteeforTanksandPressureVesselsfortheAmerican
PetroleumInstitute(API)andisvicechairmanofASME'sB96.1CommitteeforAluminumTanks.
HeholdsaBSinchemicalengineeringfromtheUniversityofCalifornia.

GeorgeL.MorovichispresidentofTank&EnvironmentalTechnologiesInc.(TETI),whichhe
foundedin1991.TETIrepresentsagroupofcompaniesofferingengineering,manufacturing,and
contractingservicesrelatedtoindustrialliquidshandling.Morovich'sprimaryfocusispetroleum
storagetankequipment,emissioncontrolsystems,waterstorage,andwastewatertreatment
equipment.Hehas20yearsofexperienceinthepetroleumstoragetankindustry.Since1989,he
hasservedtheAPIasamemberofthesubcommitteeforTanksandPressureVessels,ofthe
TaskForceonMetricationofStandards,andofanenvironmentaltechnicalassistancegroup.
MorovichholdsaBSingeographyfromSamHoustonStateUniversity.Heisarecipientofan
environmentalsciencegrantfromtheNationalScienceFoundation.

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 11/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

EarlJ.CrochetisaseniorengineeratPlantationPipeLineCo.,responsibleforcorporate
maintenance.Plantationownsarefinedproductspipelinewithabout170abovegroundstorage
tanks.Crochethasbeeninvolvedinallaspectsofabovegroundstoragetanks,firstasan
inspector,andthenlaterastheleaderofPlantation'stankintegrityprogram.CrochetholdsaBS
inmechanicalengineeringfromLouisianaStateUniversity.

Copyright1998Oil&GasJournal.AllRightsReserved.


Home Events
GeneralInterest MarketConnection
Exploration&Development WhitePapers
Drilling&Production Webcasts
1455WestLoopSouth Processing PennEnergyJobs
Houston,Texas77027 Transportation Equipment
(713)6219720 Unconventional Research
GISData&Maps
Copyright2016:PennWellCorporation RSS
AllRightsReserved.

Advertise AboutUs
NewsletterSubscription PennWell
BookStore ViewAllPennwellWebsites
PrivacyPolicy ViewAllPennwellEvents
Terms&Conditions SiteMap
ContactUs Webmaster
MagazineSubscription
Mobile

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 12/13
10/22/2016 AluminumagoodalternativetosteelforfixedrooftanksOil&GasJournal

http://www.ogj.com/articles/print/volume96/issue20/inthisissue/generalinterest/aluminumagoodalternativetosteelforfixedrooftanks.html 13/13

You might also like