Slab Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PROJECT : PRAMILA

JOB NO. :
LOCATION : NSMC-
SLAB TYPE : Two Way Slab
PREPARED BY : Er. Dipesh Katuwal

A. LOADING 0.33
Self-weight of slab = 3.00 KN/m2
total SDL = 1.20 KN/m2 0.35 0.35
Brickwall = 0.00 KN/m2
Dead Loads 4.20 KN/m2

Live Loads = 3.00 KN/m2 0.33


SLAB SHEAR FORCE COEFFICIENT
Design Loads = 10.7 KN/m2
3505 # denotes continuous
B. INPUT DATA 1 denotes discontinuous
fcu = 20 N/mm2 # ###### # #####
fy = 500 N/mm2 # #
Thickness of slab h = 125 mm # #
Top & bottom cover cl = 15 mm # #
Short span lx = 3505 mm # #
Long span ly = 3700 mm # msy # 3700
Dia. of reinf. in short span Ds = 10 mm # #
Dia. of reinf. in long span Dl = 8 mm # #
Effect.depth in short span ds = h-c1-Ds/2 = 105 mm # #
Effect. depth in long span dl = ds - Ds = 95 mm # msx #
# ###### # ####
C. REINFORCEMENT
SHORT SPAN
Hogging(-ve) Msx = 0.035 * 12.3 * 10.7 = 4.61 KNm
Sagging(+ve) Msx = 0.026 * 12.3 * 10.7 = 3.42 KNm
k = 0.021
zx = 0.95*ds OR 0.98 *ds whichever is smaller = 100 mm
Required
Hogging(-ve) Asx = Msx/0.87*fy*zs or 0.13% of bh (one face)
= 163 mm2/m
Sagging(+ve) Asx = 163 mm2/m
Provide Asx = 524 mm2/m T 10 - 150 Support O.K
Asx = 524 mm2/m T 10 - 150 Midspan O.K
LONG SPAN
Hogging(-ve) Msy = 0.032 * 12.3 * 10.7 = 4.21 KNm
Sagging(+ve) Msy = 0.024 * 12.3 * 10.7 = 3.16 KNm
k = 0.019
zy = 0.95*dl or 0.98 *dl whichever is smaller = 90 mm
Required
Hogging(-ve) Asy = My/0.95*fy*zy or 0.13% of bh (one face)
= 163 mm2/m
Sagging(+ve) Asy = 163 mm2/m
Provide Asy = 335 mm2/m T 8 - 150 Support O.K
Asy = 335 mm2/m T 8 - 150 Midspan O.K
D. DEFLECTION
Actual lx/ds = 33.4
Allowable lx/ds = 23 x 2.00 = 46.0 satisfactory

E. SHEAR STRESS
SHORT SPAN Vs = 0.35 * 10.7 * 3.51 = 13.17 KN/m
vs = 0.13 N/mm2 < 0.8 * (fcu)^0.5
100Asx/b/ds = 0.50 vcs = vc * (fcu/25)^1/3
= 0.67 N/mm2 > vs No shear reinft. required
LONG SPAN Vl = 0.33 * 10.7 * 3.51 = 12.47 KN/m
vl = 0.13 N/mm2 < 0.8 * (fcu)^0.5
100Asy/b/dl = 0.55 vcl = vc * (fcu/30)^1/3
= 0.67 N/mm2 > vl No shear reinft. required

You might also like