PMS

Solvent-based fire protective Basecoat for structural steelwork.


Indoors / outdoors

Fire resistance rating: 30 minutes; 1 hour; 1 1/2 hours; Different base coats are not applied on the
2 hours (Tests acc. International Standards) same section of steel.
Equipment is clean and free from conta-
Product Description minants or dried material.
Renitherm PMS is a white single pack thin film Wet film gauges are available for use.
coating that foams up under the effect of fire/heat
(intumescent) to form an insulating layer.
Renitherm PMS fire protection system for structural
steel is available in two different grades for internal Material Properties Renitherm PMS
and external use.
Colour shade offwhite

Application Check List Supply containers 25 kg


The following instructions are for on- site application Consistency supplied
sprayable and brushable
only. Seek our advice for off-site application. form:
Ensurethat: Flash point > +25 C
Renitherm PMS is stored correctly. Spec. Gravity, DIN 51757 1,25
Surface is dry and free from contamination.
Volume solids, DIN 3251 73 %, 2 %
Correct spray equipment is used.
VOC 350 g/l
Primer is compatible with Renitherm PMS
and is applied correctly. Shelf life min. 12 months from date of
delivery in unopened contai-
Overcoating time for the Primer has not ners stored in closed rooms at
been ecxeeded. temperatures of at least 5 C
All damage to the Primer has been repaired Drying approx. 15 hours at 15 C to
and re-primed. 20 C object temperature and
Site and weather conditions are within the 65 % rel. humidity.
Lower temperatures, higher
specification. rel. humidity and different fire
Application instruction have been read protection coating thickness
before starting of work. can prolong drying.
Surface Preparation Spray distance: approx. 30 cm
Renitherm PMS should be applied onto a clean, un-
damaged, dry and primed steel surface only. Following Tip size: recommended are 0,0190,027 inch
Primers are not compatible with Renitherm Bitumen,
Thermoplastic Primers. Contact AUDAX for compati- Thinner: Renitherm VD 1
bility of Primer if you intend to use different Primer like
Renitherm Primers. Thickness During application, measure the wet
requirements: film thickness frequently with the
Application gauge provided to ensure the correct
Renitherm PMS is supplied ready for use and must thickness being applied.
not be thinned but should be thoroughly mechanically To use the gauge, insert the teeth
stirred prior to use. into the wet basecoat. The last tooth
Substrate a compatibility test on the existing to be coated indicates the wet film
coatings with the fire protection thickness achieved.
system is recommended. In the event of over or under appli-
Any damage (impact, corrosion etc.) cations, adjustments to the loading
should be repaired prior to coating. rates of subsequent coats will be
required.
Preparation of stir thoroughly (slow rotation),
material : free of lumps. Drying times:
drying of Renitherm PMS is de-
pendent upon a number of factors
Object temp.: not below +5 C to max +50 C. including
 temperature
Relative 3080 % during application. air movement
humiditiy: Any coating application and thickness of coating
drying must be above dew point.  humidity
method of application
Method of airless spraying:
application: e quipments with a ratio of 45:1 High humidity and low air movement
Yield 4 5 Litre/min or low steel temperatures will incre-
recommended is an intermediate ase drying timees and low ambient
drying period of 2 hours for applying temperatures. Thicker coats will also
the amount of 2.000 g/m2 take longer to dry than thin coats.
brushing/rolling: several coats are Once the total loading of PMS has
necessary with intermediate drying been applied, the coating must be
time of approx. 2 hours completely dry before application of
the Topseal. This typically can be
Spray pressure: with piping length of approx 10 m: between 5 days for lower loading
a) on the gun: 180 bar and up to 15 days for maximum
b) on the paint container: 2,04,0 bar loadings. Brush or roller application
These figures can vary according may may take up to 20 % longer to
to the apparatus and length of dry compared to spraying.
piping.
Final thickness The dry film thickness (DFT) read- General Cleaning of apparatus immediately
check: ings as soon as the coating is remarks: a fter use with thinner.
sufficiently hard to allow a reading Coating may only be applied to dry
to be made without indenting the and clean surfaces.
surface. DFTs may be taken using
equipment such as permanent Storage: Renitherm PMS should be stored
magnetic type or an electrmagnetic between +5 C and +30 C and
type recorder. protected from direct sunshine. If
Ensure that the DFT of the primer stored below +5 C, material should
is deducted from the reading of the be warmed slowly. The shelf life
basecoat. Do not apply topseal until is 18 months from date of manu
the readings are in accordance with facture, subject to re-inspection
the specified thicknesses. thereafter. Containers should remain
unopened until needed. Shelf life
Top coat:
interior: may be reduced at higher storage
for decorative reasons and addi- temperatures.
tional long-term protection of the
intumescent coating we recommend
Renitherm TC or a top coat com-
patible for intumescent paints
application quantity:
1 x approx. 150 g/m2
exterior:
application of 2 x 150 g/m2 is neces- AUDAX fully complies with the
sary for structural steelwork exposed requirements of EN ISO 9001
standard. This certification is
to weathering and for use in rooms one more proof for Renitherms
with wet or humid ambient condi- quality, reliability and safety.

tions.

Maintenance: Damaged areas should be abraded


back to a sound surface preferably
by wet abrasion. The surface should
then be clean and dry before
re-applying. PMS filler may be used
for repairing scratches and chips.
Once repaired topseal should be
re-applied.