GyroPulse

Real-time gyro orientation and


measurements while drilling
The GyroPulse service allows accurate
well trajectory determination in real time.

GyroPulse U
sing GyroPulse* gyro while drilling proved during more than 2 million circulating hours.
saves rig time by providing simultaneous The gyro is mounted below the PowerPulse system
real-time gyro orienting and magnetic in a proprietary, shockproof collar to be as close
APPLICATIONS MWD on a single trip into the hole. to the bit as possible.
Surface-hole drilling from Battery life is not a concern because the turbine
multiwell platforms or pads in the PowerPulse* MWD telemetry system powers VERSATILE AND COMBINABLE
the gyro in all phases of the operation except gyro The GyroPulse service can provide real-time inertial
Oriented kickoffs
compassing. Use of the PowerPulse system allows (gyro) and gravity toolface while sliding and provide
drilling to continue to section total depth without simultaneous gyro and magnetic surveys when
FEATURES
interruption. The rig time this saves can reduce the pipe is stationary. In addition, it is combinable
Simultaneous real-time gyro
drilling costs significantly, particularly in deep water. with LWD formation evaluation services, such
and magnetic MWD surveys
as arcVISION* Array Resistivity Compensated
Reliable PowerPulse
FREQUENT, ACCURATE SURVEYS tools and other VISION* formation evaluation
telemetry, proven in more
Because it is possible to take surveys more and imaging while drilling services.
than 2 million circulating
often, well trajectories determined from GyroPulse
hours of operation
surveys are generally more accurate than those MWD SURVEYING ENHANCEMENT
Real-time inertial and gravity derived from multiple gyro single-shot runs or The GyroPulse service is an enhancement to
toolface while sliding gyro steering tools run on wirelinethe traditional conventional MWD surveying, allowing accurate
Ability to combine with LWD methods for making directional surveys when well trajectory determination with no additional
formation evaluation services there is magnetic interference from nearby rig time in situations in which there is magnetic
Gyro battery that is used wells. Such interference often is a problem interference from nearby wells. This reduces
only for gyro compassing when drilling surface holes from multiwell the risk of both stuck pipe and well collision
PowerPulse turbine powers platforms or performing oriented kickoffs. in surface holes. The fact that the service
gyro at other times can be combined with simultaneous formation
PROVEN RELIABILITY evaluation measurements while drilling yields
Reliability of the PowerPulse MWD telemetry further savings in rig time and provides additional
system used in the GyroPulse service has been data for optimum well placement.
A single source for MWD and gyro services
GyroPulse Directional SpecificationsGyro Sensor Uphole connection,
Directional measure point from GyroPulse reference point 1.80 ft [0.55 m] 75/8-in regular box
Toolface
Uphole saver sub
Update period 5s
Accuracy (1 s) 1 (3 resolution) Uphole connection,
Survey time to display 90 s at 6 bps 75/8-in H-90 box
Inclination accuracy (1 s) 0.1
Azimuth accuracy (1 s) below 20 inclination 1
For inclination of less than 20, the accuracy of the gyro is equal to or higher than that of conventional MWD measurements.
9.5-in OD

PowerPulse Directional SpecificationsMWD Sensor


Inclination Range Accuracy
Stationary 0 to 180 0.1 at 1 s
Continuous 20 to 180 0.2 at 1 s
Azimuth
Stationary 0 to 360 1 at 1 s
Continuous 20 to 340 2 at 1 s
Toolface
Stationary 0 to 360 1.0 at 1 s
Continuous 0 to 360 1.0 at 1 s
Gamma ray
Stationary 0 to 250 API 7%

GyroPulse Mechanical Specifications


Collar OD 9.5 in [24.13 cm]
Collar ID 5.90 in [14.99 cm]
Distance to
Collar length 24.88 ft [7.58 m]
survey point,
Weight with gyro insert 4,250 lbm [1,927.8 kg] 1.8 ft
Drill collar connections
Uphole 7 58-in H-90 box
Downhole 7 58-in H-90 pin
Joint makeup torque
Uphole INCONEL saver sub to drill collar 74,000 to 83,000 ft.lbf [100,331 to 112,533 N.m]
Drill collar to downhole INCONEL saver sub 80,000 to 89,000 ft.lbf [108,465 to 120,668 N.m]
Gyro-MWD
Bending strength ratio (BSR)
reference point
Uphole connection 2.64 (readout port)
Downhole connection 2.69
Moment of inertia 370 in4
Equivalent bending stiffness 26.2 ft [7.99 m]
Maximum dogleg
Sliding 10.5/100 ft [10.5/30.48 m]
Rotating 7.5/100 ft [7.5/30.48 m] Downhole connection,
Flow range 400 to 1,200 galUS/min [1.5 to 6.1 m3/min] 75/8-in H-90 pin
Pressure drop Less than 60 psi [413 kPa]
Maximum pressure 20,000 psi [137,895 kPa] Downhole saver sub
Maximum differential pressure 5,000 psi [34,474 kPa]
Maximum temperature 300F [150C] Downhole connection,
Maximum torque 35,000 ft.lbf [47,454 N.m] 75/8-in regular pin,
4.1875-in inside
Maximum weight on bit 340,000/L2 lbf
diameter (ID)
Maximum tensile load 1,094,000 lbm [496,230 kg]
Maximum system shock level 30 min at Shock Level 3 (50 g threshold), or accumulated 200,000 shocks above 50 g
Other sizes available on request GyroPulse tool.
L = distance between stabilizers in feet
GyroPulse
GyroPulse gyro while drilling offers
simultaneous real-time gyro orienting
and conventional magnetic MWD
on a single trip into the hole.

Versatile and combinable

ADVANTAGES
Significant rig-time savings, particularly in deep water
Frequent and accurate directional surveys in environments where there is magnetic interference
Lower risk of stuck drillpipe because pipe is stationary for less time
Smaller survey ellipsoid of uncertainty, facilitating closer well spacing in surface holes
Single source for MWD and gyro services
Safer operationno wireline rig-up and rig-down required

www.slb.com/pulse

*Mark of Schlumberger
Other company, product, and service
names are the properties of their owners.
Copyright 2008 Schlumberger. All rights reserved. 08-DR-101