ETAMIC PROBES
DIGITAMIC
EXTENSIONS
Displacement sensor metrology characteristics 2
The ETAMIC probe has numerical metrological characteristics. The measurement
range, sensitivity, correlation and accuracy errors are among the most important ones.
The combination of the precision and accuracy errors helps to define the intrinsic error.
Accuracy, as well as precision, are concepts that associate correlation and repeatability; therefore,
are not a characteristic of metrology (to the contrary of the intrinsic error).
Note that it is preferable to use the terms correlation error and repeatability error instead of
accuracy.
CORRELATION ERROR
For analog displacement probes with differential
transformer (L.V.D.T), the linear error identifies
itself with the correlation error.
It is determined from the mastering curve
- see example shown -
The calibration curve shows that in the central area of the zero, the linear error is reduced.
For a probe of 1mm, the linear error is less than 1m in an interval of 0.2mm,
which is 0.125%.
Outside the central area, the max linear error linear error
is of .5% from the measured point.
For the entire measuring range,
the linear graphic representation
is in the shape of a bow.
For incremental probes, the linear errors are greatly reduced to the use of a graduated
optical scale and to an electronic process integrated in the head.
The max linear error is 0.50m on the entire measuring range, for probes of 12.5 and
25.0mm.
ACCURACY ERROR
For all LVDTs the repeatability or accuracy error is less than 0.15m for all the L.V.D.T
probes. For the entire Line of products, the display resolution and the quantification pitch of
the digital/analog converter are taken in consideration.
For example, for a probe of 1mm associated with a 14 bit converter, the quantification
pitch p will be :
E
p=
n
with E = measuring range
n = number of points equal to 214 = 16584 points
therefore p = 0.12m
With the resolution of 0.1m, the rounded max repeatability error could reach 0.2
whereas a resolution of 0.01m would not exceed 0.15m.
3 Summary
Example of instrumentation 15
Specials applications 16
. Applications
C1
C3
C1
D
C4
H
C2
C1 C2
A : mechanical
retraction of 10mm
Measure
Probe ZDB 033 ZDB 103 ZDB 253 ZDB 503 ZDB 743 ZDB 1003
description (straight) (straight) (straight) (straight) (straight) (straight)
Part Number E339412/001 E339412/003 E339412/008 E339412/011 E339412/021 E339412/022
Measuring range 0.3mm 1mm 2.5mm 5mm 1mm 10mm
Measuring force
(horizontal probe) 0.70N 0.70N 0.70N 0.70N 0.70N 0.70N
Repeatability error < 0.15m < 0.15m < 0.15m < 0.15m < 0.15m < 0.30m
Linear error
- in the central area 0.3m 1m 2.5m 5m 1m 10m
- outside the central area
(% of read value) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Storage temperature -40C to +105C -40C to +105C -40C to +105C -40C to +105C -40C to +105C -40C +105C
Operating temperature -10C to +80C -10C to +80C -10C to +80C -10C to +80C -10C to +80C -10C +80C
NOTE :
The mini LVDT probes are not equipped with ball guiding.
Therefore the mini probes are not intented for supporting laterals stress on the
contact tip.
Straight LVDT probes, ZDB pneumatic retraction 6
ZDB 109 ZDB 259 ZDB 509
E339412/007 E339412/010 E339412/013
The probes are shown at electric zero.
thrust or retraction
.
electronic probes
valve control
device
In an idle position, the probes
are in position of measurement;
4 holes
the measuring pressure is given
by the spring.
The retraction is of the contact
tip is obtained by the release.
1/4 BSP . Accessories :
pneumatic plate for retraction
- pneumatic plate for probes with
or thrust probes retraction : E344138/000
pressure idle
position position
principle CSZ...
valve control
device
4 holes
In the idle position
the probes are in
the retracted position.
Measuring position
1/4 BSP
. Accessories : is obtained by pressure.
- pneumatic plate for probe with pneumatic plate for retraction
or thrust probes
pneumatic push : E344010/000
Measuring strength 0.80N to 0,4bar 0.85N to 0.4bar 0.70N to 0.4bar 0.35N to 0.4bar 0.70N to 0.4bar
(horizontal probe) 2.50N to 1bar 2.50N to 1bar 2.50N to 1bar 1.90N to 1bar 2.50N to 1bar
Repeatability error < 0.15m < 0.15m < 0.15m < 0.15m < 0.30m
Storage temperature -40C to +105C -40C to +105C -40C to +105C -40C to +105C -40C to +105C
Operating temperature -5C to +80C -5C to +80C -5C to +80C -5C to +80C -5C to +80C
Protection index IP65 IP65 IP65 IP65 IP65
Pneumatic (b) 0.4 < P < 1 0.4 < P < 1 0.4 < P < 1 0.4 < P < 1 0.4 < P < 1
push (MPA) 400 < P < 1000 400 < P < 1000 400 < P < 1000 400 < P < 1000 400 < P < 1000
pressure (PSI) 6 < P < 14 6 < P < 14 6 < P < 14 6 < P < 14 6 < P < 14
Incremental probes, ZIB 8
Acquisition kit
Ref : 237119805 Way 2 : optional
PROBE
Way 1 :
to 31 sensors
. Interface :
- Input : direct connection with the
probe by cable (2m)
- Output : transmission speed
187.5 Kbauds or 9600 bauds
travel
Pneumayic P push (bars) 0.4 < P < 0.6 0.4 < P < 0.6
(MPA) 400 < P < 600 400 < P < 600
(PSI) 6 < P < 8.5 6 < P < 8.5
Contact tip for probes 10
The ETAMIC probes come with two types of contact tips :
. Standard contact tips that come with probes only can not be ordered
separately.
. Special contavt tips on order only.
5 Knurled
5 Knurled
5 Knurled
Wide flat
contact tip XT 12.E X320004/004
hardened steel
8 Knurled
R16 Spheric
Contact tip
hardened XT 12.F X320002/004
steel
. Tightening
Anvil assembly
- X404004/000
wrench
Incremental 8 m - 237278089
68
LVDT 3m - E401257/043
21,5
LVDT 8 m - E401257/048
Probe
E341359/000
collet
clamp screw
Probe support
with screw
E343457/000
perpendicular
to the probe
Probe support
with screw 1.5 Allen key
E342971/000
parallel
to the probe
support glued
Adaptor
M12x1/M16x1 E343540/000
and +
probe collet E341359/000
. Description
The Digitamic is used with one or two probes. It is designed to perform very accu-
rate measurements. The Digitamic is low cost, simple, easy to integrate and user
friendly. The module aspect of the Digitamic simplifies the connection and data
exchange between units and/or external network.
. Features
The DIGITAMIC offers the following benefits :
. In shop measurement (in harsh conditions).
. High sensitivity.
. Large choice of probes.
. Easy installation.
. Static or dynamic measurements.
13 Digitamic digital comparator
. Configuration
The Digitamic digital reference gauge is fully programmable using three data
entry keys :
Display.
. Actual dimension or difference from a floating zero.
. metric or inch.
. Dimension status : within specification, oversize or undersize.
. Reversible display.
Measurement.
. Simple or differential.
. Dynamic gauging with hold feature : max, min, max-min, (max+min)/2.
. Upper and lower limits.
. Zero offset.
. Compensation for surface finish.
. Memorization of measurement result with auto reset at each gauging cycle.
Mastering.
. With one master anywhere within part specification limits.
. With one set of min-max masters, the Digitamic computes the gain
automatically based on certified values of the masters.
. Technical characteristics
. description
and Function
The Etamic linear measuring block XP90S
is a key element of the modular measurement
product range.
A gauge finger with contact is used to measure
adjustable stop and spring the particular part or object.
contact The slide is mounted on a precision ball
surface
guide which is connected to the gauging
finger/contact.
The gauge finger transmits its motion to the
measuring element (electric probe, indicator
unit etc.).
XP90S measuring blocks can be mounted
side by side and connected to one or more
accessories in the modular measuring
products range.
. Dimensions 40 10
2 M6 depth 10
(attachment on sole-plate)
(side attachment)
. Characteristics
. Part number : E343503/000 . Standard springs :
. Travel : 3mm in relation to center position - springs with no color (original assembly 300g)
. ETAMIC specifies a measurement pressure - red spring : 30g (delivered with XP90S)
between 110g and 150g - yellow spring : 160g (delivered with XP90S)
- blue spring :250g (delivered with XP90S)
. Accessory
Description Annotation Part number Visualisation
Probe locking
Micro retraction - E342636/000 collet
cylinder
Attachment system
for electric probe - E343428/000
or dial indicator
15 Examples of measuring chains
Digitamic
Digitamic
CMZ03
CMZ03
16
. Special applications
Cone depth
ETAMIC reserves the right to make any changes to its products to reflect improvements in methods and technology, without notice. 03/02
assembly
Slide assemblies
Joint fitting
controls