Steel Deck Fastening Systems

Why use Hilti steel deck fastening systems?


Innovative Hilti deck fastening systems offer many advantages to the steel erector, contractor, structural
engineer, architect, building official and owner.

RELIABILITY

Ductile and tough, knurled shank steel fastenings improve resistance to wind and seismic forces
Consistent performance in rough project site conditions, largely independent of operator skill level
Code compliant and tested to the latest ICC-ES AC43 requirements for IBC recognition.
FM and UL approved for wind and fire resistance; SDI and CSSBI listed

PRODUCTIVITY
Ergonomic stand-up deck fastening tools with fastening speeds significantly faster than other means (e.g.
welding, screwing, punching)
Quick set-up time for loading, re-loading and troubleshooting; less erection time in the controlled decking zone
Total installed costs can be significantly less than AWS arc spot puddle welding; no special tools required for
proprietary deck types
Use On Demand and Tool Fleet Management tool placement options for erectors

TECHNICAL SUPPORT
Local field engineers and steel and metal project specialists available to assist with training and guidance on
design and specification
Professional decking submittals for steel erectors contractors
Profis DF Diaphragm Design Software with optimization features for structural engineers
Design load tables, guideline specifications and CAD details

SAFETY TRAINING

Hilti Deck Fastening Training Manual


Free ANSI A10.3 Operator Safety Training and manufacturer licensing
Local Hilti Account Managers and Field Engineers available on the jobsite, everyday, to assist in making sure
steel erectors know how to do it right the first time

HEALTH, SAFETY AND WELFARE


Self-contained fastening system designed to the highest level of safety
No associated worker health hazards such as toxic fumes from welding
No burns, no fire hazards, no electrical power cords or tripping and fall hazards
Reduced worker back stress with ergonomic stand-up fastening tools

APPEARANCE

No unsightly weld burn through; no need for touch up paint or zinc coatings as when damaged
by welding
Easy visual identification of proper installation
Clean fastening appearance with reduced need for re-fastening

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Deck Fastening Technical Guide Table of Contents


Section Description Page
1.1 Steel Deck Fastener Design and Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1.1 Terminology and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1.2 Steel Deck Diaphragm Design and Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1.3 Fastener, Tool and Cartridge Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.1.4 Submittal Information for Roof Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.1.5 Submittal Information for Floor Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.1.6 Fastener Quantity Estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.1.7 Common Steel Deck Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.1.8 Diaphragm Shear and Stiffness Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.1.9 How to use Diaphragm Shear Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
1.2 X-HSN24 for Fastening Deck to Bar Joist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
X-HSN 24 fastener for attachment of many types of steel deck
to bar joist from 1/8 inch to 3/8 inch thick
1.3 X-ENP-19 for Fastening Deck to Structural Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
X-ENP-19 fastener for attachment of many types of steel deck
to structural steel greater than or equal to 1/4-inch thick
1.4 Racing Tip Screw Deck Fastening System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Hilti S-MD 12-24x1-5/8 M HWH5 Racing Tip fastener for attachment
of many types of steel deck to gauge purlin or thin bar joist
1.5 SLC Sidelap Connectors for Fastening Deck to Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
S-SLC 01 and S-SLC 02 sidelap connectors and Hilti No. 10 HWH screws
for many types and gauges of steel deck
1.6 Optimized Diaphragm Shear Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1.7 X-HVB Shear Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Mechanically attached X-HVB shear connector for use in composite beam
construction with steel beams and concrete slabs

X-HSN 24 Powder-Actuated and X-ENP-19 Fastening SLC-01 and SLC-02


Racing Tip Screw Fastening Systems System for Structural Steel Sidelap Fastening Systems
for Bar Joist or Gauge Purlin

Hilti steel deck fastening systems have been extensively Please see the sections 1.2, 1.3, 1.4 and 1.5 for more
evaluated and hold all relevant building code approvals and information on specific product approvals, evaluations and
evaluations including ICC-ES, COLA, FM and UL. application limits.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 1
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1. Terminology and Definitions 1.1.1.3 Steel Deck Definitions


1.1.1.1 Fastener Terminology Base Material - The existing part of the work that is a base
for the fastening. The structural steel or bar joist framing
DX = Hilti terminology for direct fastening
members in steel deck applications.
powder-actuated technology
Beam - One of the principal horizontal supporting members
ENP = Hilti fastener type used for attaching steel deck
of a building.
to structural support steel with DX 76 and
DX 860-ENP powder-actuated tools Burn through - Unintended welding-related holes created
(X-ENP19 L15) in steel deck.

F = diaphragm flexibility factor, micro-inch/lb Button punch - A mechanical means of connecting two
(mm x 10-6/N) pieces of sheet metal together by crimping with a special
tool. This method is used on BI or interlocking deck panels.
G' = diaphragm shear stiffness lb/in. (N/mm x 10-6)
Direct fastening - A fastening method in which the
HSN = Hilti High Shear Nail fastener type for attaching fastenings are made without any preparation steps such
steel deck to bar joist support steel used as drilling a hole. Examples are powder-actuated fastening
with DX 860-HSN and DX 460-SM and self-drilling screws.
powder-actuated tools (X-HSN 24)
Diaphragm deck - A decking system which is designed
q = allowable diaphragm shear, plf (N/mm) to carry lateral loads due to wind or seismic action in addition
Qf = structural connector strength, lb (kN) to gravity loads and wind uplift.

Qs = fastener strength, panel to panel, lb (kN) Endlap - The overlap of adjacent steel deck panels at the
ends of the panels (end edges perpendicular to the steel
Sf = fastener flexibility factor, panel to frame, deck panel fluting). Typically specified as 2 or 4 inches.
in./kip (mm/kN) Butted deck with no endlap is used for some steel deck
Ss = fastener flexibility factor, panel to panel, (e.g., cellular).
in./kip (mm/kN) Fastener pattern - The number and spacing of fasteners at
t f ( t || ) = flange thickness of beam or bar joist for steel each support for a steel deck panel.
deck applications, in. (mm) Fastened material - The component that must be attached
ICC-ES = International Code Council - Evaluation Service to the base or supporting material.

SDI = Steel Deck Institute Fastening - The combination of fastener, fastened material
and base material all in final position.
CSSBI = Canadian Sheet Steel Building Institute
Fastening system - The fastener, fastening tool and driving
1.1.1.2 X
 -HVB Shear Connector power source all taken together as a system with specific
Terminology performance characteristics.

hr = nominal rib height, in. (mm) Gauge - A measure of thickness for sheet metal. Reference
Section 1.1.7 for common steel deck gauges.
Hs = connector height, in. (mm)
Interlocking sidelap (BI Connection) - Steel deck panels
Nr = number of connectors in one rib
having male and female side edges. The adjacent deck panel
q = allowable shear strength, lb (kN) male and female edges interlock into each other when the
deck is installed. The interlocks are fastened together using
Qn = nominal shear strength, lb (kN)
button punches, proprietary punch systems, welds,
Rg = coefficient to account for group effect or screws.
wr = average width of rib, in. (mm) Joist - A structural member in a building which is used to
support a floor or roof.
Ycon = distance from top of steel beam to top
of concrete slab, in. (mm)

2 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1


Nestable sidelap - Steel deck type in which the side edge Pullout - As related to fasteners, a failure mode that occurs
of a steel deck panel contains a partial valley profile and when the fastener pulls out of the base steel support.
overlaps, or nests" on top of the side edge of the adjacent
Pullover - As related to fasteners, a failure mode that occurs
steel deck panel, which contains a full valley profile. Often
when the steel deck panel pulls over the fastener head or
fastened together using self-drilling stitch screws.
washer(s).
Non-diaphragm deck - A steel deck system which is
Punch systems - A mechanical means of connecting two
designed to carry only gravity loads.
pieces of sheet metal together by punching through the steel
Powder-actuated cartridge - A powder filled metal casing to create a flap of metal which is then crimped. This is done
used as the source of driving energy in a powder-actuated with a proprietary pneumatic tool on interlocking deck panels.
tool. The ANSI A10.3 terminology is a cased powder load."
Purlin - A secondary horizontal structural member attached
Powder-Actuated Fastener (PAF) - A nail or threaded to the primary frame and supporting the roof covering.
stud fastener capable of being driven into steel, concrete or
Sidelap - The side edge overlap of adjacent steel deck
masonry. Fasteners may be equipped with washers suitable
panels (side edges parallel to the steel deck panel fluting).
for clamping the fastened material to the base or supporting
material. Also referred to as Hilti DX, powder-actuated Stitch screws - Screws used to fasten the overlapping edges
fasteners (PAF), power-driven fasteners (PDF), drive pins of two deck panels between joists or beams.
or shot pins. Tack weld - A weld of no structural significance. Used for
Powder-actuated, Indirect-acting tool - A powder-actuated temporary attachment of steel to the supporting frame. A
tool in which the expanding gas of the powder load acts on weld made to hold the parts in proper alignment until the final
a captive piston, which in turn drives the fastener into the welds are made.
base material. If the test velocity of the lightest fastener when Uplift - Vertical load on the steel deck panels due to
using the strongest powder load is less than 328 fps (100 wind forces.
m/s), the tool meets the ANSI A10.3 requirements and is
classified as a low-velocity tool. All Hilti powder-actuated Wind tacking - Limited fastening of the steel deck panel
tools used in the construction industry are classified as at the edges to hold the panels in place until all specified
low-velocity. fastenings have been made.

Profis DF Diaphragm Software - Hilti developed,


revolutionary design and submittal generator program.
It incorporates a powerful design optimization feature
to produce cost-effective and reliable steel
deck solutions.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 3
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1.2 Steel Deck Diaphragm Design and Theory


1.1.2.1 General Discussion
A steel deck diaphragm is a horizontal assembly that resists 1. Steel Deck Profile Type and Thickness
wind, seismic and other lateral forces. A diaphragm can 2. Supporting Steel Frame Spacing or Deck Span
be modeled as a horizontal beam with interconnected floor 3. Frame Fastener Type and Spacing (connector for steel
and roof deck units that act as the beam web. Intermediate deck to steel frame)
joists or beams act as web stiffeners and perimeter beams or 4. Sidelap Fastener Type and Spacing (connector for steel
reinforcement on the diaphragm perimeter act as the beam deck panel edge to edge)
flanges. Figure 1, based on graphics from the Steel Deck 5. Safety Factors (ASD) or Resistance Factors (LRFD/LSD)
Institute (SDI) Diaphragm Design Manual, depicts a roof deck based on load type (wind, seismic, other) and fastening
diaphragm model. type (mechanical, weld)
ICC Evaluation Services recognizes both design methods
Design of steel deck diaphragms has traditionally been
as acceptable in AC43, Acceptance Criteria for Steel
done using the Steel Deck Institute (SDI) Diaphragm Design
Deck Roof and Floor Systems. An ICC Evaluation Service
Manual or Technical Manual (TM) 5-809-10 Seismic Design
Report (ESR) based on ICC-ES AC43 provides recognition
for Buildings, Departments of the Army, Navy and Air Force
for use with the IBC. Hilti deck fasteners are currently listed
(Tri-Services Design Manual). Both methods provide the basic
in the SDI DDM03 and Appendix VI, VII and VIII and were
equations for determining the strength and stiffness of the
evaluated in ICC-ES ESR-3592, ESR-2776 and ESR-2197.
diaphragm considering the following parameters:
Hilti deck fastener performance with proprietary sidelap
clinching systems is also documented in ESR-1735P,
ESR-1116, ESR-1169, ESR-1414 and ESR-2408. Additional
industry research on quasi-static and seismic/cyclic load
performance of diaphragms is ongoing. Other system
approvals and evaluation reports are pending.

Figure 1: Diaphragm Model

1.1.2.2 Fastener Test Programs


Many small element and full scale test programs have
been conducted using Hilti deck fasteners to evaluate their
performance.

1. Small Element Connection Tests

Small element connection tests are used to determine AISI S905 Test Methods for Mechanically Fastened Cold-
fastener pullout, pullover and lap-joint shear strength and Formed Steel Connections
stiffness with sheet steel and base steel representative of ASTM E1190 Standard Test Methods for Strength of
typical construction. The data is analyzed and used in a Power-Actuated Fasteners Installed In Structural Members
predictive model to calculate the performance of the larger ICC-ES AC70 Acceptance Criteria for Fasteners Power
steel deck diaphragm assembly or system. These tests are Driven Into Concrete, Steel and Masonry Elements
conducted in accordance with the following standards, and
ICC-ES AC118 Acceptance Criteria for Tapping Screw
shown in Figure 2. Fasteners

4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

Figure 2: Small Element Connection Tests


2. Full Scale Diaphragm System Tests

Full scale diaphragm system tests are used to determine ICC-ES AC43 Acceptance Criteria for Steel Deck
the strength and stiffness of a larger steel deck diaphragm Roof and Floor Systems
assembly directly. The data is analyzed and fit in a predictive
AISI S907 Cantilever Test Method for Cold-Formed
model to address varying configurations of base steel, steel
Steel Diaphragms
deck, specific fastener combinations and spans. These tests
are conducted in accordance with the following standards and ASTM E455 Standard Test Method for Static Load
shown in Figures 3, 4 and 5. Testing of Framed Floor or Roof Diaphragm
Constructions for Buildings

Figure 3: ICC-ES AC43 Diaphragm Test Frame Schematics

30
'-0
"

"
24'-0

Figure 4: AC43 Diaphragm Test Frame


Fastening Systems Research Laboratory (FSRL), Schaan, Liechtenstein

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 5
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection


Hilti powder-actuated deck fasteners are recognized
alternatives to arc spot puddle welds and self-drilling screws.
The fasteners can be used on roof deck diaphragms as well
as composite concrete filled floor diaphragms. Hilti provides
Load (kips)

training for powder-actuated tool operators in accordance


with ANSI A10.3 Safety Requirements for Powder-Actuated
Fastening Systems.

Hilti Mechanical Fastening Systems Provide Superior


Solutions for Attaching Steel Deck to Steel Support
Members
Displacement [inch]
Consistent Fastening Quality
Figure 5: AC43 Deck Diaphragm Load Displacement Curve
High Production Rate
No Burn Throughs or Joist Damage from Welding
Superior Cyclic Load Performance

1.1.2.3 Proper Fastener Selection and Steel Deck Layout


(Pre-Fastener Installation)
Selection of the proper Hilti deck fastener depends on the Rolled beam or wide Angles or joist top chords
supporting base steel thickness as shown in Section 1.1.3.1. flange shape bx
The Hilti Deck Fastener Selection Gauge shown in Figure 6 should
t ||
be used by the decking installer to confirm fastener selection. t ||
The cut-out slot on the gauge is fit against the bar joist top chord
or steel beam flange. As the internal card slides in the gauge, the 3/8"
3/8"
proper Hilti deck fastener is highlighted with a green box. A red
box indicates that the corresponding Hilti deck fastener is outside bx 8 t ||
the base material application limits and should not be used for Figure 7: Edge Distance Recommendations
steel deck fastening to the base material being gauged.
Extra care must be taken at the endlap and corner lap
conditions where multiple layers of steel deck nest or interlock
on adjacent panels. It is particularly important that endlap
and corner lap conditions of two and four deck layers must
be snug and tight against one another and the supporting
steel frame in order for the fastening to be made as shown
in Figure 8. Tight endlap and corner lap requirements are
independent of the fastening type and contribute directly to
the performance of arc spot welds, screws, powder-actuated
fasteners, punches and crimps/clinches. If the steel deck
Figure 6: Hilti Deck Fastener Selection Gauge endlaps and corner laps are not tight, a proper fastening
cannot be made.
Steel deck installers must layout deck properly and mark
frame fastening lines in order to ensure that steel deck
panels are connected to the supporting steel frame. Marking
frame fastening lines is essential when attaching steel deck
to thin base steels (tII < 1/4"), including open web steel joists.
For all applications, the fasteners should be installed at least
3/8" (10 mm) from the edge or toe of the joist top chord or light
steel beam flange. Additionally, when installing into a bar joist
top chord (angle), the fasteners need to be installed at a distance
from the angle, bx 8 x tII. Reference Figure 7 for edge distance
and bx dimensions.
Figure 8: Tight Nesting of Steel Deck Sheets

6 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

1.1.2.4 Fastener Inspection (Post-Fastener Installation)


Steel deck construction projects may present a challenge Section 1.1.2.3). The fastener point must penetrate into,
with respect to the quality control of connections between but not necessarily through, the supporting steel (top chord
sheet steel and the supporting steel structure. Quality control or flange), depending on the fastener/deck/base steel
for traditional fastening methods may present a challenge configuration.
as they typically consist of visual checks and dimensional 2. Clamping of fastened part to base material.
or size verifications, which may or may not confirm a proper The fasteners must clamp the steel deck down to the base
fastening. Field verification of the adequacy of powder- steel (top chord or flange). There should not be any visible
actuated mechanical steel deck fastenings can be conducted gaps between the steel deck and the base steel or between
as described in this section. steel deck laps.
The use of mechanical fasteners does not imply a need 3. Washer placement and condition. In general, the
to inspect every fastening point unless specified by the fastener washer edges must be clamping the steel deck sheet
Structural Engineer. No guideline standards are published to the base steel. The washers should not curl upwards away
by SDI, AWS, AISC or OSHA for percentages of steel from the deck surface and must not be digging or cutting into
deck connections that must be checked or that can be the steel deck surface. For the X-HSN 24 fastener, the top
unsatisfactory. This determination must be made by the hat washer must be compressed. For the X-ENP-19 fastener,
Structural Engineer and Authority Having Jurisdiction. the piston mark (indentation) should be clearly visible on the
Hilti has multiple services and fastener washer as shown in Figure 10.
aids in place that help ensure
steel deck fastenings are done
correctly the first time. Together
with a commitment to field Piston Mark
quality control by the steel
deck installer, these systems
may alleviate the need for post-
fastener installation inspection.
Hilti has over one thousand
Account Managers and Field
Engineers available for training
Figure 10: X-ENP-19 L15 Piston Mark (indentation)
steel deck installers. This hands-
on training includes the use When the inspector is unclear about the compression of the
of the Hilti Powder-Actuated top hat washer or the piston mark, the Hilti Power Adjustment
Tools in accordance with ANSI Guide may be used to measure for optimal powder-actuated
Figure 9: A10.3 safety requirements, use fastener nailhead stand-off, hNVS. Note that measuring nail
Hilti Power of the Deck Fastener Selector head stand-off does not verify proper fastener embedment
Adjustment Guide Gauge, proper steel deck layout unless the steel deck and base material are tightly clamped,
and end/corner lap nesting as discussed in Section 1.1.2.3. with the base steel not deformed or bent. Conversely,
Proper powder-actuated fastener, tool and cartridge selection measuring nail head stand-off does not confirm an improper
as discussed in Section 1.1.3, as well as the use of the Hilti fastening. If slightly outside the range, further investigation
Power Adjustment Guide, shown in Figure 9 and discussed into the three characteristics of proper fastenings given above
in more detail in Section 1.1.3.3, are also key elements of the should be completed.
installer training. Furthermore, the Hilti DX 860-HSN tools The following Figures 11 and 12 provide visual examples
come equipped with piston brakes, which virtually eliminate of proper and improper steel deck fastenings for Hilti
the possibility of overdriven fasteners. powder-actuated bar joist (X-HSN 24) and structural steel
There are three main characteristics of proper fastenings that (X-ENP-19 L15) fasteners, respectively.
must be considered: Inspection of the installed steel deck and installation of roof
1. Fasteners installed in proper locations. The fasteners coverings, insulation and membrane should be done soon
must be installed in the proper steel deck valleys or flutes in after steel deck installation to assist in alleviating corrosion
accordance with the structural roof and floor deck plans and or other issues that could arise due to long-term exposure.
design, and in the proper location in the base steel (Reference Fasteners must be completely protected from the weather
within 180 days after installation.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 7
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

hNVS well above Top Hat not collapsed, not


optimal range* snug against steel deck
and not clamping deck
sheet to base steel

Figure 11a: Under Driven X-HSN 24 Fastener with Single Sheet to


Base Steel

hNVS within Top Hat properly


optimal range* collapsed, snug against
steel deck and clamping
deck sheet to base steel

Figure 11b: Properly Driven X-HSN 24 Fastener with Single Sheet to


Base Steel

hNVS well below Washer cutting into deck


optimal range* sheet, deforming base
steel and deck sheet

Figure 11c: Over Driven X-HSN 24 Fastener with Single Sheet to


Base Steel

* Optimal stand-off (hNVS) range for the X-HSN 24 fastener is 5 mm hNVS 9 mm.

8 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

hNVS well above Piston mark (indentation) not


optimal range* visible on fastener
Gap visible between washers

Washers not clamping deck


sheet to base steel

Figure 12a: Under Driven X-ENP-19 Fastener with Single Sheet


to Base Steel.

hNVS within Piston mark (indentation)


optimal range* clearly visible on fastener

Washers snug against


one another and clamping
deck sheet to base steel

Figure 12b: Properly Driven X-ENP-19 Fastener with Single Sheet


to Base Steel

hNVS well below Washers cutting into deck


optimal range* sheet, deforming base
steel and deck sheet

Figure 12c: Over Driven X-ENP-19 Fastener with Single Sheet


to Base Steel

* Optimal stand-off (hNVS) range for the X-ENP-19 fastener is 8.2 mm hNVS 9.8 mm.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 9
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1.3 Fastener, Tool and Cartridge Selection

Solutions for bar joist (open web joists) applications (Reference Section 1.2 and 1.4)

DX 460-SM

SLC 01 SLC 02 #10 HWH

DX 860-HSN X-HSN 24 or S-MD 12-24 x 1-5/8 M HWH5 (Racing Tip 5)

SDT 5
Solutions for structural steel applications (Reference Section 1.3)

DX 76

SLC 01 SLC 02 #10 HWH

X-ENP-19 L15

DX 860-ENP-L

SDT 5

10 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

1.1.3.1 Fastener Selection


Table 1 - Bar joist and light structural steel frame fasteners (Reference Section 1.2
and 1.4)
Base Fastener Recommended
Material1 Type2 Installation Tool
X-HSN 243
Bar Joist and Structural Steel
DX 860-HSN
1/8" (3 mm) tf 3/8" (10 mm)

S-MD 12-24x1-5/8 M HWH5


Gauge Purlin and Light Bar Joist
SDT 5
0.0598" (1.5 mm) tf 1/4" (6 mm)

1 Steel base material strength (Fu ) shall be in the range of 58 to 91 ksi for base steel thicknesses (tf ) less than or equal to 5/16". For base
steel thicknesses greater than 5/16", the tensile strength shall be in the range of 58 to 75 ksi.
2 The X-HSN 24 and Racing Tip Fastening Systems will fit in all deck types except A-deck.
3 This fastener can be used with structural steel within the thickness ranges shown.

Table 2 - Structural steel frame fasteners (Reference Section 1.3)


Base Fastener Recommended
Material1 Type2 Installation Tool

Structural Steel, X-ENP-19 L15


Hardened Structural Steel
DX 860-ENP-L
and Heavy Bar Joist
t f 1/4" (6 mm)

1 Steel base material tensile strength (Fu ) shall be in a range of 58 to 91 ksi.


2 X-ENP-19 L15 fasteners fit in all types of deck except A and F.

Table 3 - Deck-to-deck sidelap fasteners (Reference Section 1.5)2


Deck Fastener Recommended
Gauges Type1 Installation Tool
S-SLC 01 M HWH
18 to 26
3
SDT 5

S-SLC O2 MHWH
16 to 22 SDT 5

Hilti #10 HWH Screw


16 to 26 SDT 5

1 For use with all types of nestable deck or screwable interlocking deck.
2 Other sidelap connector types are possible with Hiltis powder actuated frame fasteners. Please reference the Steel Deck Institute (SDI)
Diaphragm Design Manual 3rd Edition (DDM03).
3 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength (45 Fu 65 ksi) steel deck.
For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH.

Sealing Caps
The SDK2 is an SAE 316 stainless steel sealing cap with a
neoprene seal. This is installed over the head of the X-ENP-19
fastener using the SDK2 hand setting
tool. The SDK2 sealing cap provides
added corrosion protection for exposed
exterior steel deck applications in SDK2 Setting Tool SDK2 Sealing Cap X-ENP-19 L15
accordance with IBC requirements. hnvs = 8.2 mm- 9.8 mm

Note: The sealing cap and fastener must be installed correctly to achieve a water-resistant seal. Contact Hilti for details.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 11
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1.3.2 Tool Selection


Bar joist and light structural steel powder-actuated frame tools (Reference Section 1.2)

DX 860-HSN The DX 860-HSN stand up decking tool is a fully automatic powder-


actuated tool designed for attaching steel deck to steel base materials.
With a high fastening rate and 40-fastener magazine, the DX 860-
HSN can significantly help reduce the time it takes to attach deck.
Fastenings can be made on very thin support structures without the
need for weld washers. Suitable for base steels with a thickness of
1/8" to 3/8". Fastens X-HSN 24 collated fasteners.

DX 460-SM The DX 460-SM decking tool is a medium duty powder-actuated


tool with adjustable power regulation used for attaching steel deck
to steel base materials. This system is best suited for deck with a
flute width of 1/2" or greater and for base steels with a thickness of
3/16" to 3/8". Fastens X-HSN 24 collated fasteners.

Structural steel powder-actuated frame tools (Reference Section 1.3)

DX 860-ENP-L The DX 860-ENP-L is a fully automatic powder-actuated tool


designed for attaching steel deck to structural steel beams. The
tool has capacity of 1 strip of 40 cartridges and 4 flexible strips of
10 each X-ENP-19 fasteners in an MXR collated configuration.

The DX 860-ENP-L is ergonomically designed to work in an upright


position, and can be loaded without the operator bending over. The
system is suitable for deck with a flute width of 3/4" or greater and
base steels with a thickness of 1/4" or greater.

DX 76 The DX 76 decking system is a heavy duty fastening system


consisting of semi-automatic, low-velocity powder-actuated tool,
fasteners and cartridges for attaching steel deck to steel base
materials. Special features include cartridge power regulation which
allows for high productivity. This system is suitable for deck with
a flute width of 3/4 or greater and base steels with a thickness of
1/4 or greater. Use with X-ENP-19 fasteners in single, MX or MXR
collated configurations.

Gauge purlin and light bar joist screw frame tool and deck-to-deck sidelap fastening tool
(Reference Section 1.4 or 1.5)

SDT 5 The SDT 5 stand up decking tool is a steel deck sidelap and frame
fastening tool. Combined with the DX 860-HSN or DX 860-ENP-L,
these tools deliver a high speed, high productivity system for
mechanical attachment of steel deck. The SDT 5 can consistently
drive up to 50 S-MD 12-24x1-5/8 M HWH5 frame fasteners or
SLC sidelap connectors before reloading. Its comfortable, durable
design features an 18 position torque clutch to provide consistent
fastening quality. In a competitive market, the SDT 5 represents
a major gain in productivity essential to staying on time and on
budget.

12 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

1.1.3.3 Powder-Actuated Cartridge and Power Regulation Selection


When installing powder-actuated deck fasteners, it is Cartridge colors available for
important for the installed fasteners to have a nailhead Hilti decking tools are (in order of
stand-off, hNVS, within the specified range. The Hilti Power increasing power): yellow, blue,
Adjustment Guide, shown in Figure 13, is a valuable quality red and black. All Hilti decking
assurance aid to the decking foreman. It is primarily intended tools come equipped with a
for power adjustment of the powder-actuated tool. This is power adjustment capability. The
done by installing test fastenings into representative base settings on the power regulation
steel and then checking the nailhead stand-off, hNVS, at the dials range from 1 to 4.
beginning of the work to achieve the optimal cartridge and Figures 14 and 15 provide the
tool power level. This is a critical step in the work because installer with a recommended
of variations in the structural steel strengths (Fy, Fu ) and cartridge color and power setting
member thicknesses. By investing time up front and properly for Hilti bar joist and structural
correlating the fastening system to actual site materials, most steel deck fasteners, respectively.
fastening issues can be avoided. During installation, it is also These charts are guidelines that
advisable for the foreman to check the work periodically to the installer can use to start
spot deficiencies before large portions of the deck might be the process of test fastenings
Figure 13:
fastened incorrectly. Failure to properly set the tool, fastener discussed above. This also helps
Hilti Power
and cartridge prior to starting work can decrease fastening ensure the installer will have the
Adjustment Guide
quality consistency. proper color cartridges on the
Prior to starting work, the installer shall install a test fastening project site.
and check the hNVS using the Hilti Power Adjustment Guide.
If necessary, the installer shall adjust the power or force that
drives the fastener into the base steel. There are two ways to
accomplish this power adjustment. One is by use of different
cartridge colors and the other is by adjusting the power
regulator on the tool itself.
Base material thickness tII [inches]

Base material thickness tII [inches]

X-HSN 24 X-ENP-19

Figure 14: Cartridge and Power Regulation Guidelines for Figure 15: Cartridge and Power Regulation Guidelines for
Bar Joist Deck Fasteners installed with a DX 860-HSN1 Structural Steel Deck Fasteners1
1 Cartridge recommendations for the X-ENP-19 fastener are acceptable for all current Hilti Decking Tools for attachment to structural steel.
Cartridge recommendations for the X-HSN 24 fasteners are for the DX 860-HSN. Cartridge recommendations for the DX 460-SM can be
found in the tool operator manual. Recommendations are guidelines only and require verification on each site.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 13
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1.4 Submittal Information for Roof Deck


Hilti Account Manager: Date:
Phone: DDAATT:
Decking Installer: Hilti Regional Field Engineer:
Contact Name (Last, First): Phone:
Installer Trained by Hilti: l Yes l No, please schedule training Fax/e-mail:
Engineer of Record: Contact Name (Last, First):
Phone: Fax/e-mail:
Project Name: Project Zip Code:
Total Area: Deck Manufacturer:
Building Code: 2012 IBC 2009 IBC 2006 IBC Other Design Reference: SDI ICC-ES CSSBI Other
Submittal Recipient: Decking Installer Account Manager Other:
Bar Str.
Joist Steel Design Diaphragm Shear
Zone _______ Support Span (ft) _______ Support Steel Capacity (plf) ________
Subst. Frame: X-ENP-19 RT5 Subst. Sidelap: Hilti SLC # 10 Screw # 12 Screw Exposed to Weather
X-HSN 24 Button Punch Proprietary Punch System
Deck Type Deck Gauge Frame Type Frame Pattern Sidelap Type Sidelap Pattern Base Thickness
B (1.5") 24 1/2" PW 36 / 9 #10 Screw _____# Per Span < 3/16"
BI (1.5") 22 5/8" PW 30 / 7 #12 Screw _____(in.) On Center 3/16"
N (3") 20 3/4" PW 24 / 5 Button Punch 1/4"
Other 18 #12 or #14 Screw __ / 4 _______(in.) Top Seam Weld Length 5/16"
16 Other 3 Proprietary Punch System 3/8"
__ Other > 3/8"

Bar Str.
Joist Steel Design Diaphragm Shear
Zone _______ Support Span (ft) _______ Support Steel Capacity (plf) ________
Subst. Frame: X-ENP-19 RT5 Subst. Sidelap: Hilti SLC # 10 Screw # 12 Screw Exposed to Weather
X-HSN 24 Button Punch Proprietary Punch System
Deck Type Deck Gauge Frame Type Frame Pattern Sidelap Type Sidelap Pattern Base Thickness
B (1.5") 24 1/2" PW 36 / 9 #10 Screw _____# Per Span < 3/16"
BI (1.5") 22 5/8" PW 30 / 7 #12 Screw _____(in.) On Center 3/16"
N (3") 20 3/4" PW 24 / 5 Button Punch 1/4"
Other 18 #12 or #14 Screw __ / 4 _______(in.) Top Seam Weld Length 5/16"
16 Other 3 Proprietary Punch System 3/8"
__ Other > 3/8"

Bar Str.
Joist Steel Design Diaphragm Shear
Zone _______ Support Span (ft) _______ Support Steel Capacity (plf) ________
Subst. Frame: X-ENP-19 RT5 Subst. Sidelap: Hilti SLC # 10 Screw # 12 Screw Exposed to Weather
X-HSN 24 Button Punch Proprietary Punch System
Deck Type Deck Gauge Frame Type Frame Pattern Sidelap Type Sidelap Pattern Base Thickness
B (1.5") 24 1/2" PW 36 / 9 #10 Screw _____# Per Span < 3/16"
BI (1.5") 22 5/8" PW 30 / 7 #12 Screw _____(in.) On Center 3/16"
N (3") 20 3/4" PW 24 / 5 Button Punch 1/4"
Other 18 #12 or #14 Screw __ / 4 _______(in.) Top Seam Weld Length 5/16"
16 Other 3 Proprietary Punch System 3/8"
__ Other > 3/8"
Notes

Fax or email completed forms to Hilti Technical Support at (918) 459-3004 or deck@hilti.com.
14 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

1.1.5 Submittal Information for Floor Deck


Hilti Account Manager: Date:
Phone: DDAATT:
Decking Installer: Hilti Regional Field Engineer:
Contact Name (Last, First): Phone:
Installer Trained by Hilti: Yes No, please schedule training Fax/e-mail:
Engineer of Record: Contact Name (Last, First):
Phone: Fax/e-mail:
Project Name: Project Zip Code:
Total Area: Deck Manufacturer:
Building Code: 2012 IBC 2009 IBC 2006 IBC Other Design Reference: SDI ICC-ES CSSBI Other
Submittal Recipient: Decking Installer Account Manager Other:

Bar Str.
Joist Steel Design Diaphragm Shear
Zone _______ Support Span (ft) _______ Support Steel Capacity (plf) ________
Subst. Frame: X-ENP-19 RT5 Subst. Sidelap: Hilti SLC # 10 Screw # 12 Screw
X-HSN 24 Button Punch Proprietary Punch System
Deck Type Deck Gauge Frame Type Frame Pattern Sidelap Type Sidelap Pattern Base Thickness
B (1.5") 28 1/2" PW 36 / 9 #10 Screw _____ # Per Span < 3/16"
B (1.5") 26 5/8" PW 30 / 7 #12 Screw _____ (in.) on Center 3/16"
N (3") 24 3/4" PW 24 / 5 Button Punch 1/4"
2" x 12" 22 #12 or #14 Screw __ / 4 ____ (in.) Top Seam Weld Length 5/16"
3" x 12" 20 Other 3 Other 3/8"
9/16" 18 __ > 3/8"
Other 16
Normal Weight Concrete. . . 3000 psi _________(Inches) Concrete Depth Above Top of Flute
Lightweight Concrete. . . . . 3500 psi
4000 psi
Insulating Concrete. . . . . . . 130 psi
Perform Calculations based on Shear Studs Present in Design
Deck fastened at a 36/4 pattern with standing seam sidelaps fastened by button punches @ 36" O.C. maximum.
Refer to ICC-ES ESR-2197, Tables 10-17, for more details.

Minimum Concrete Shear Reinforcement .00075 bw s2 .00025 bw s2

Minimum Average Spacing of Shear Studs 12" 18" 24" 30" 36"

Minimum Welded Wire Fabric for Tabulated Shear Values 6 x 6 W 1.4 x W 1.4
6 x 6 W 2.0 x W 2.0
6 x 6 W 2.9 x W 2.9
6 x 6 W 4.0 x W 4.0
4 x 4 W 4.0 x W 4.0
6 x 6 W 7.5 x W 7.5
6 x 6 W 8.3 x W 8.3

Notes

Fax or email completed forms to Hilti Technical Support at (918) 459-3004 or deck@hilti.com.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 15
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

1.1.6 Fastener Quantity Estimation


Table 4 - Frame fasteners per square of roof1,2,3 Sidelap fastener estimation
Fastener Fastener Support Spacing, ft
To estimate the number of sidelap screws
Pattern spacing 4.0 4.5 5.0 5.5 6.0 6.5 7.0 8.0
on a steel roof or floor deck project,
36/11 6" 78 69 63 59 53 50 46 40
multiply the total deck area in square
36/9 6" 61 56 50 45 43 39 36 33
feet times the number of required stitch
36/7 6" 53 48 43 39 37 34 32 28
screws per span and then divide by
36/5 6-12-12-6 37 33 30 28 26 24 23 20 the sheet width times the joist spacing
36/4 12" 29 26 22 22 21 19 18 16 (both in feet). A 5% contingency is also
36/3 18" 21 19 17 16 15 14 13 12 recommended for waste and loss.
30/6 6" 53 48 43 39 37 34 32 28
30/4 6-18-6 34 30 28 26 24 22 21 19 Example:
30/3 12-18 24 22 20 19 17 16 15 14 Total area: . . . . . . . . . 50,000 square
24/5 6" 53 48 43 39 37 34 32 28 feet
24/3 6" 29 26 22 22 21 19 18 16 Sheet width:. . . . . . . . 36" = 3 ft
24/4 8" 41 37 34 31 29 27 25 22
Joist spacing:. . . . . . . 5 ft
1 Hilti Profis DF Diaphragm software also estimates fastener quantities.
No. of sidelap fasteners per span: 5
2 Estimated quantities are for one square of decking. A square of roof decking is an area of 100 ft 2.
No provision is made for waste. Perimeter fastening spacing is based on 12" on-center assumption.
3 For interlocking sidelaps, add 15% to quantities in table.
# of screws needed =
50,000 ft2
x 5 x 1.05 = 17,500
1.1.7 Common Steel Deck Dimensions 3 ft x 5 ft
Table 5 - Common steel deck types and dimensions1,3
Deck Common Standard Table 6 - Steel deck gauge (GA)
Type Thickness Dimensions inch and millimeter equivalent2,3
6" Nominal Sheet
1.5"

Gauge
2.5" Steel Thickness, t
(GA)
in. (mm)
B 16-24 GA
1.75"
16 0.0598 (1.52)
36"
18 0.0474 (1.21)
20 0.0358 (0.91)
6" 2.5" 3.5"
1.75" 22 0.0295 (0.76)
BI 16-24 GA
1.5"

24 0.0239 (0.61)
36"
26 0.0179 (0.45)

8"
28 0.0149 (0.38)
2.75" 1 Dimensions shown are typical. However,
the Structural Engineer should always
3"

N 16-22 GA consult with the steel deck manufacturer


on the dimensions for the specific product
1.75"
24" as they can vary depending on the
0.75"

manufacturer.
2 Deck gauge inch equivalents taken from
6"
SDI Diaphragm Design Manual. Millimeter
1.5"

1.75" equivalents taken from CSSBI Design of


Steel Deck Diaphragms.
F 18-22 GA 3 Calculations to produce diaphragm shear
0.5"
36" tables with the deck profiles and gauges
shown are possible with Hilti Profis DF
Diaphragm software.
12"
3"
0.75"

7.25"
1"

Composite
16-22 GA
Deck
4.75" 36"
9/16"

1.5" 2.5"
Form Deck 24-28 GA
1"
30"

16 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

1.1.8 Diaphragm Shear and Stiffness Calculations


Background: An extensive independent laboratory test For other steel deck diaphragm conditions (e.g. deck profile,
program was conducted investigating the performance of deck gauge, concrete-filled, etc.) not represented in the tables
steel deck diaphragms attached with Hilti fasteners. The found in this section, use Hilti Profis DF Diaphragm software
program test scope consisted of full scale diaphragm system or reference ICC-ES ESR-2197.
tests conducted in accordance with ICC-ES AC43, as well as
Steel deck diaphragm strength design equations:
comparative small element lap-joint shear tests conducted
in accordance with AISI S905 Test Methods for Mechanically Pn Qf
S ne = = (2 x 1 + 2 x 2 + n e ) x , plf (Eq. 2.2-2)
Fastened Cold-Formed Steel Connections. The resulting full < <
scale and small element test data was analyzed and predictive
Qf
equations were developed for the steel deck diaphragm S ni = {2 x A x ( - 1) + B} x , plf (Eq. 2.2-4)
<
system strength and stiffness using specific combinations of
Hilti fasteners. S = Q x N 2 x B2 , plf (Eq. 2.2-5)
nc f
< x N2 + B2
2

For simplicity and familiarity, the Steel Deck Institute (SDI)


Diaphragm Design Manual, 3rd Edition (DDM03) method Sn = least of Sne, Sni, and Snc, plf
equations are used as the basis for determining the steel
deck diaphragm strength and stiffness. Specific Hilti fastener S = c x Sn , plf
strength and stiffness values and test data correlation
with:
adjustment factors were developed to provide 95% or greater
accuracy with test results per ICC-ES AC43 requirements. 1
B = ns x s + x [ 2 x 2 x S ( xp2 ) + 4 S ( xe2 ) ]
w2
The resulting design information is documented in this
section and in ICC-ES ESR-2776 (Hilti SLC), ESR-3592 and 1.5 x < v Q
= 1- 0.7 s = s
ESR-2197 (Hilti #10 HWH Screw). 240 x t Qf
where:
Design: Design equations for calculating steel deck
diaphragm strength (S) and stiffness (G') or flexibility factor (F) t = nominal steel deck thickness, in. (Reference Table 6)
with Hilti X-HSN 24, X-ENP-19 L15 or S-MD 12-24x1-5/8 M
w = deck width
HWH5 frame fasteners and Hilti Sidelap Connectors (SLC) are
provided. The equation numbers in parenthesis correspond N = number of fasteners per unit length across the width, ft -1
to the equation numbers provided in the SDI DDM03. The
xe = xp = distance from panel centerline to any fastener in a
design equation variables needed for common steel deck
panel at the end (xe) or purlin (xp) supports
diaphragm applications are found in Tables 7 through 9. The
conversion factors for Allowable Stress Design (ASD), Load S = nominal diaphragm shear strength, plf
Resistance Factor Design (LRFD) and Limit States Design < v = span, ft < = panel length = 3 x < v, ft
(LSD) provided in Table 11 shall be applied to the values
determined from the design equations in order to produce the ne = ns = 3 x < v x 12 (sidelap connector spacing in inches)
final Allowable Diaphragm Shear, SASD or Factored Resistance c = correlation factor for diaphragm system effect
Diaphragm Shear, SLRFD or SLSD, respectively. The calculated
SASD, SLRFD or SLSD Diaphragm Shear values do not take into Reference Tables 7 and 8 for description and values of other
account steel deck buckling and must be checked against the variables for common conditions.
appropriate buckling diaphragm shear value, Sbuckling, found
Uplift and combined loading: Allowable loads to resist uplift
in Table 12. Reference Sections 1.2, 1.3 and 1.4 for pre-
forces are provided in the individual sections for each frame
calculated diaphragm shear and stiffness tables for the
fastener. Reference SDI DDM03 Section 4.10 for combined
X-HSN 24, X-ENP-19 and S-MD 12-24x1-5/8 M HWH5
tension uplift and diaphragm shear interaction. Uplift and
fasteners, respectively.
combined loading calculations are shown in the Example
The design equations and load values in this section are for Problem at the end of this section on pages 22 and 23.
36" wide, 1-1/2" deep wide rib steel deck panels (B-Deck or
BI-Deck types) and are limited to the fastener patterns shown
in Figure 16 and sidelap connector spacings greater than 3"
and in accordance with Table 10.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 17
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection


Steel deck diaphragm stiffness and flexibility factor With:

( )
1
design equations: t
C = 29,500
x x S x S x < x 12 (Eq. 3.3-1)
Ext w f
1 + 2 + ns x f
G' = Ss
3.78 + 0.9 x Dn + C , kips/in. (Eq. 3.3-3)
D
Dn = (Eq. 3.3-2)
1000 < x 12
F= , micro-inches/lb
G'
Reference Tables 7 and 9 for description and values of other
E = modulus of elasticity for steel = 29,500 ksi variables for common conditions.

Table 7 Diaphragm strength (S) and stiffness factor (G') equation variable values
1 end 2 purlin D-Warping constant, in.
Deck Fastener Sxe2, Sxp2, N,
distribution distribution A
type pattern in.2 in.2 ft-1 22 GA 20 GA 18 GA 16 GA
factor factor
1-1/2" 36/11 3.667 3.667 1944 1944 2 3.000 1548 1164 756 540
Wide 36/9 3.000 3.000 1656 1656 2 2.333 1548 1164 756 540
Rib B- 36/7 2.000 2.000 1008 1008 1 2.000 1548 1164 756 540
Deck or 36/5 1.667 1.667 936 936 1 1.333 9096 6804 4464 3144
BI- 36/4 1.333 1.333 720 720 1 1.000 12864 9624 6312 4452
Deck 36/3 1.000 1.000 648 648 1 0.667 26508 19824 13008 9180

Table 8 Diaphragm strength (S) equation variable values


Deck gauge (inches)
Configuration 22 20 18 16
(0.0295) (0.0358) (0.0474) (0.0598)
Min. deck Frame fastener Qf, lb Qs, lb Qf, lb Qs, lb Qf, lb Qs, lb Qf, lb Qs, lb
Deck tensile Sidelap
(yield) base material Correlation Correlation Correlation Correlation
type strength, connector1,2
ksi thickness, in. factor, c factor, c factor, c factor, c
X-HSN 24 Hilti 1357 844 1824 1260 1865 1701
1/8 tf < 3/16 SLC 1.155 1.172 1.203
X-HSN 24 Hilti 1590 844 2107 1260 2663 1701 3035 2024
3/16 tf 3/8 SLC 1.121 1.102 1.066 1.028
45 (33)
X-ENP-19 Hilti 1597 844 2112 1260 2764 1701 3079 2024
tf 1/4 SLC 1.257 1.205 1.106 1.000
S-MD 12-24x1-5/8 M HWH5 Hilti 1193 717 1661 870 1860 1152 1860 1453
0.0598 tf 1/4 SLC 1.000 1.000 1.000 1.000
B
X-HSN 24 Hilti 1357 844 1824 1260 1865 1701
1/8 tf < 3/16 SLC 1.155 1.172 1.203
X-HSN 24 Hilti 1941 954 2208 1341 2698 1859 3095 2343
3/16 tf 3/8 SLC 1.052 1.054 1.058 1.062
92 (80)
X-ENP-19 Hilti 1964 954 2165 1341 3022 1859 3577 2343
tf 1/4 SLC 1.197 1.166 1.108 1.046
S-MD 12-24x1-5/8 M HWH5 Hilti 1193 717 1661 870 1860 1152 1860 1453
0.0598 tf 1/4 SLC 1.000 1.000 1.000 1.000
X-HSN 24 Hilti 1357 844 1712 1111 1865 1591
1/8 tf < 3/16 SLC 1.155 1.172 1.203
X-HSN 24 Hilti 1516 882 1712 1111 2450 1591 2553 2051
BI 45 (33)
3/16 tf 3/8 SLC 1.284 1.233 1.140 1.040
S-MD 12-24x1-5/8 M HWH5 Hilti 1193 717 1661 870 1860 1152 1860 1453
0.0598 tf 1/4 SLC 1.000 1.000 1.000 1.000
X-HSN 24 Hilti #10 1489 633 1795 769 2348 1018 2924 1284
1/8 tf 3/8 HWH Screw 1.000 1.000 1.000 1.000
B 1603 633 1933 769 2529 1018 3149 1284
45 or 92 X-ENP-19 Hilti #10
or (33 or 80) tf 1/4 HWH Screw 1.000 1.000 1.000 1.000
BI
S-MD 12-24x1-5/8 M HWH5 Hilti #10 1193 633 1661 769 1860 1018 1860 1284
0.0598 tf 1/4 HWH Screw 1.000 1.000 1.000 1.000
1 Sidelap connector spacing must meet the requirements of Table 10.
2 Reference Table 3 and Section 1.5 for more information on the proper selection of Hilti Sidelap Connectors (SLC).

18 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1


Table 9 Diaphragm stiffness (G') and flexibility factor (F) equation variable values
Deck gauge (inches)
Configuration 22 20 18 16
(0.0295) (0.0358) (0.0474) (0.0598)
Min. deck Sf, in./kip Sf, in./kip Sf, in./kip Sf, in./kip
Deck Frame Sidelap
tensile (yield)
type fastener connector1 Ss, in./kip Ss, in./kip Ss, in./kip Ss, in./kip
strength, ksi
Hilti SLC or 0.0073 0.0066 0.0057 0.0051
X-HSN 24
Hilti #10 HWH Screw 0.0175 0.0159 0.0138 0.0123
B
45 or 92 Hilti SLC or 0.0044 0.0040 0.0034 0.0030
or X-ENP-19
(33 or 80) Hilti #10 HWH Screw 0.0175 0.0159 0.0138 0.0123
BI
Hilti SLC or 0.0076 0.0069 0.0060 0.0053
S-MD 12-24x1-5/8 M HWH5
Hilti #10 HWH Screw 0.0175 0.0159 0.0138 0.0123
1 Reference Table 3 and Section 3.5.4 for more information on the proper selection of Hilti Sidelap Connectors (SLC).

Table 10 Minimum recommended sidelap connector spacing (Inches center-to-center) for X-HSN 24 and X-ENP-19
powder-actuated fasteners with B-Deck or BI-Deck type
Frame fastener Frame fastener pattern
Deck
base material 36/3 36/4 36/5 36/7 36/92 36/112
gauge
thickness, in.
SLC1 #10 SLC1 #10 SLC1 #10 SLC1 #10 SLC1 #10 SLC1 #10
22
X-HSN 24 20 12 6 12 6 6 3 6 3 6 3
1/8 tf < 3/16
18
16
22
12 3
X-HSN 24 20
3/16 tf 3/8 6 3 6 3 3 3 3 3 3 3
18

16
22
X-ENP-19 20
6 3 6 3 6 3 3 3 3 3 3 3
tf 1/4 18
16
1 Hilti SLC spacings less than those tabulated may be used. The tabulated spacing should be used in the calculation of diaphragm shear strength when using
the Qf, Qs and c values from Table 8. Alternatively, only when the SLC spacings are less than those tabulated, the Qf, Qs and c values found in Table 8 can be
replaced by the following values.

X-HSN 24 All deck types, strengths and base steel thicknesses listed in Table 8
22 Gauge (0.0295 in.)- Qf = 1489 lb, Qs = 716 lb, c = 1.000
20 Gauge (0.0358 in.)- Qf = 1795 lb, Qs = 869 lb, c = 1.000
18 Gauge (0.0474 in.)- Qf = 2348 lb, Qs = 1151 lb, c = 1.000
16 Gauge (0.0598 in.) - Qf = 2924 lb, Qs = 1452 lb, c = 1.000

2 For 36/9 and 36/11 patterns, when wind (or seismic) diaphragm shear capacities exceed the values shown below, the fastening pattern must be increased at
the building perimeter, chords, collectors or other shear transfer elements to two fasteners per rib (i.e. 36/14 pattern). The wind (or seismic) diaphragm shear
capacity must not be greater than that determined from the 36/9 and 36/11 patterns, as applicable.

X-HSN 24 with steel support framing thicknesses 1/8" tf < 3/16"


ASD wind (seismic) LRFD wind (seismic) LSD wind (seismic)
22 Gauge (0.0295 in.) - 1275 plf (1200 plf) 2100 plf (1950 plf) 28.5 N/mm (26.3 N/mm)
20 Gauge (0.0358 in.) - 1600 plf (1500 plf) 2625 plf (2450 plf) 35.8 N/mm (32.8 N/mm)
18 Gauge (0.0474 in.) - 1825 plf (1700 plf) 3000 plf (2675 plf) 39.0 N/mm (37.2 N/mm)

X-HSN 24 with steel support framing thicknesses 3/16" tf 3/8"


ASD wind (seismic) LRFD wind (seismic) LSD wind (seismic)
22 Gauge (0.0295 in.) - 1400 plf (1300 plf) 2300 plf (2125 plf) 31.0 N/mm (28.8 N/mm)
20 Gauge (0.0358 in.) - 1700 plf (1600 plf) 2800 plf (2600 plf) 37.9 N/mm (35.0 N/mm)
18 Gauge (0.0474 in.) - 2250 plf (2100 plf) 3700 plf (3425 plf) 50.0 N/mm (46.3 N/mm)
16 Gauge (0.0598 in.) - 2775 plf (2600 plf) 4550 plf (4225 plf) 61.7 N/mm (56.9 N/mm)

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 19
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection


Table 11 Conversion factors for Allowable Stress Design (ASD), Load Resistance Factor Design (LRFD)
and Limit States Design (LSD)

Design Multiply calculated diaphragm


For
method shear strength by1,2
Diaphragms mechanically connected to the structure subjected to
0.400
earthquake loads or load combinations which include earthquake loads
Diaphragms mechanically connected to the structure subjected
ASD 0.426
to wind loads or load combinations which include wind loads
Diaphragms mechanically connected to the
0.400
structure subject to all other load combinations
Diaphragms mechanically connected to the structure subjected to
0.650
earthquake loads or load combinations which include earthquake loads
Diaphragms mechanically connected to the structure subjected to
LRFD 0.700
wind loads or load combinations which include wind loads
Diaphragms mechanically connected to the
0.650
structure subject to all other load combinations
Diaphragms mechanically connected to the structure subjected to
0.600
earthquake loads or load combinations which include earthquake loads
Diaphragms mechanically connected to the structure subjected
LSD 0.650
to wind loads or load combinations which include wind loads
Diaphragms mechanically connected to the
0.600
structure subject to all other load combinations
1 Conversion factors determined from Table D5, of AISI S100.
2 Diaphragm capacities should be limited to the respective ASD, LRFD and LSD buckling diaphragm shear capacities found in Table 12.

Table 12- ASD and LRFD diaphragm shears (plf) and LSD diaphragm shears (N/mm) for buckling, Sbuckling1,2
Moment of Span, <v (ft-in.)
Steel Deck Deck
inertia, I
type gauge 3'-0" 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0"
mm4/mm
ASD (plf)
Standard 1-1/2- 22 0.152 8444 4750 3040 2111 1551 1188 938 760 628 528
inch deep flutes, 20 0.198 11000 6188 3960 2750 2020 1547 1222 990 818 688
6-inches center- 18 0.284 15778 8875 5680 3944 2898 2219 1753 1420 1174 986
to-center 16 0.355 19720 11094 7100 4931 3622 2773 2191 1775 1467 1233
LRFD (plf)
Standard 1-1/2- 22 0.152 13511 7600 4864 3378 2482 1900 1501 1216 1005 844
inch deep flutes, 20 0.198 17600 9900 6336 4400 3233 2475 1956 1584 1309 1100
6-inches center- 18 0.284 25244 14200 9088 6311 4637 3550 2805 2272 1878 1578
to-center 16 0.355 31556 17750 11360 7889 5796 4438 3506 2840 2347 1972
Moment of Span, <v (mm)
Steel deck Deck
inertia, I
type gauge 900 1200 1500 1800 2100 2400 2700 3000 3300 3600
mm4/mm
LSD (N/mm)
Standard 1-1/2- 22 208 192.6 108.3 69.3 48.1 35.4 27.1 21.4 17.3 14.3 12.0
inch deep flutes, 20 270 250.0 140.6 90.0 62.5 45.9 35.2 27.8 22.5 18.6 15.6
6-inches center- 18 388 359.3 202.1 129.3 89.8 66.0 50.5 39.9 32.3 26.7 22.5
to-center 16 485 449.1 252.6 161.7 112.3 82.5 63.2 49.9 40.4 33.4 28.1
1 Load values based upon a safety factor () of 2.00 for ASD, a phi factor () of 0.80 for LRFD or a phi factor () of 0.75 for LSD.
2 Diaphragm shears in this table are for steel deck buckling failure mode only and are to be used as prescribed in Section 1.1.8. If design condition is not
tabulated, diaphragm shears for buckling may be calculated using the following equations:
For ASD, Sbuckling = (I x 106/(< v)2) / 2.0 , plf
For LRFD, Sbuckling = (I x 106/(< v)2) x 0.8 , plf
For LSD, Sbuckling = (I x 106/(< v)2) x 0.75 , N/mm

20 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

Pattern 36/3 Pattern 36/4

Pattern 36/5 Pattern 36/7

Pattern 36/9 Pattern 36/11

Note 1: Nestable B-Deck shown. Interlocking BI-Deck with screwable sidelap is also covered by the equations discussed in Section 1.1.8.
Note 2: Bar joist shown. Connection to structural steel members also covered by the equations discussed in Section 1.1.8.

Figure 16: Common frame fastener patterns

Refer 2" min. Hilti


to Note Fastener

Note: Some patterns


may require two
fasteners in one flute.
Fasteners may be
installed on either side
of the structural steel
beam or bar joist.

17a. Frame fastener attachment of 17b. Steel deck endlap condition


steel deck to frame

17c. Sidelap connector with B-Deck 17d. Sidelap connector with screwable BI-Deck

Figure 17: Typical frame, endlap and sidelap connections

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 21
Steel Deck Fastening Systems

1.1 Steel Deck Fastener Design and Selection

Example problem
Design parameters: Design problem:

Load type: Wind Determine allowable diaphragm


Design method: ASD shear strength (SASD), uplift
Span: 6'-0" (Tn (ASD)) and stiffness (G') for the
Deck: 20 GA. 1-1/2" B-Deck (fu 45 ksi) given steel deck diaphragm
Base steel: Bar joist with 1/4" top chord and check against
Frame fastener pattern: 36/7 required loads.
Sidelap fastener spacing: 12" O.C.
Frame fastener: X-HSN 24
Sidelap fastener: Hilti SLC
Required diaphragm shear (Q): 650 plf
Hilti
Required uplift (T): 35 psf SLC

6"
36" 1-1/2" X-HSN 24

SDI HNA
Calculation steps DDM03 Technical
Ref. Guide
Step 1: Calculate nominal diaphragm shear strength limited by edge fasteners:
Eq. Sec.
This calculation is not required when the number of edge connectors (ne) equals the number of sidelap 2.2-2 1.1.8
fasteners (ns). In these cases, Sne does not limit diaphragm shear strength.
Step 2: Calculate nominal diaphragm shear strength limited by interior panel fasteners:
Q 2107
S ni = {2 x A x (- 1) + B} x f = {2 x 1 x (0.802 - 1) + 16.99} x = 1,942 plf
< 18
with:
1.5 x < v 1.5 x 6
= 1- = 1- = 0.802 0.7
240 x t 240 x 0.0358 Sec.
1.1.8
1 [2 x 2 x 1008 + 4 x 1008] Eq.
B = ns x s + x [ 2 x 2 x S ( xp2 ) + 4 S ( xe2 ) ] = 18 x 0.598 + = 16.99 and
2.2.3
w 2
362 Tables
where: 7 and 8
3 x < v x 12 3 x 6 x 12
ns = ne = = = 18
Sidelap Spacing 12
Qs 1260
s = = = 0.598
Qf 2107

Step 3: Calculate nominal diaphragm shear strength limited by corner fasteners: Sec.
1.1.8
N xB
2 2
2.00 x 16.99
2 2
Eq.
S nc = Q f x = 2107 x = 1,798 plf and
<2 x N 2 + B 2 182 x 2.002 + 16.992 2.2-5
Tables
7 and 8
Step 4: Apply correlation factor, c, to determine correlated nominal diaphragm shear strength Sec.
S = c x Sn = 1.102 x 1,798 = 1,981 plf 1.1.8
where: and
Sn = least of Sne, Sni and Snc = Snc = 1,798 plf Table 8

Step 5: Apply appropriate conversion factor to determine allowable diaphragm strength Sec.
Table 11
SASD (wind) = S x Conversion Factor = 1,981 x 0.426 = 844 plf 2.4

Step 6: Check to see if steel deck buckling controls


Sbuckling (ASD) = 2,750 plf > SASD (wind) therefore, SASD (wind) = 844 plf 650 plf Table 12

22 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Steel Deck Fastener Design and Selection 1.1

SDI HNA
Calculation steps DDM03 Technical
Ref. Guide
Step 7: Calculate diaphragm stiffness:
Ext 29,500 x 0.0358
G' = = = 86 kips/in.
3.78 + 0.9 x Dn + C 3.78 + 0.9 x 5.39 + 3.65
1000 1000
F= = = 11.6 micro-inches/lb
G' 85.99
where: Sec.
D 1164 1.1.8
Dn = = = 5.39 Eq.
< x 12 18 x 12 and
3.3-3
1 Tables
C =Ex
t x Sf
w (
x + + n x Sf
1 2 s
Ss
1
)
x < x 12
7 and 9

C = 29,500 x
0.0358 x 0.0066
36 (
x 2 + 2 + 18 x 0.0066
0.0159 ) x 18 x 12 = 3.65

Step 8: Calculate nominal uplift resistance:


K x Tn,f 6.00 x 1,680
Tn = = = 560 psf Roof
C x <v 3x6
Deck Sec.
Where:
Const. 1.2.3
K = Number of frame fasteners per deck sheet per joist/beam = 6.00
C = Width of deck sheet = 3 feet Handbook
Tn,F = Controlling ultimate tension capacity of frame fastener = 560 lb x 3.0 = 1,680 lb

Step 9: Apply uplift safety factor to determine allowable uplift resistance:


Tn 560
Tn (ASD) = = = 187 psf 35 psf
UP
3.00

Step 10: Check combined loading:


xQ xT
0.85 x ( ) + ( UP ) 1.0
S Tn Sec.
4.10
2.35 x 650 3.00 x 35
0.85 x ( ) + ( ) 1.0 0.843 1.0
1981 560
Note: The Hilti Profis DF Diaphragm software provides full calculations for diaphragm shear and stiffness when desired.

Hilti is a leading manufacturer of direct fastening systems for Diaphragm data is calculated in accordance with SDI
steel and metal applications. As a member of the Steel Deck Diaphragm Design equations using specific Hilti fastener
Institute (SDI), Hilti participates in and supports steel deck strength and stiffness values with data correlation adjustment
industry research at leading universities and test labs. Recent factors in accordance with ICC-ES AC43 requirements.
research projects with Hilti direct fastening systems have
included inelastic seismic deck diaphragms and deep deck /
cellular deck diaphragms.

Independent tests are the best guide to product performance


and reliability, a philosophy to which Hilti and the SDI
subscribe. The support for ongoing research programs
is indicated by the number and scope of tests already
performed and by the policy of sponsoring new tests when
new products or applications are introduced. Hilti provides
direct fastening system performance data, ICC-ES Evaluation
Service Reports, design software, fire ratings and load test
results for Hilti direct fastening systems used in steel deck
applications.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 23
36/3 914/3

6'' 152 mm
Steel Deck Fastening Systems 36'' 1-1/2'' 914 mm 38 mm

1.1 Steel Deck Fastener Design and Selection


EDN IMPERIAL EDN

1.1.9 How to use Diaphragm Shear Tables


General: The following Product Technical 36/4 Guide Sections 1.2 Traditional diaphragm
36/3 shear tables:
914/4 Sections 1.2, 1.3 and
to 1.6 provide Hilti fastener product6''technical data sheets and 1.4 provide tables
6''
in 152
a format
mm
similar to those published in 152 mm
36''
pre-calculated diaphragm shear and stiffness
36'' tables using
1-1/2''the the SDI DDM03, CSSBI and most1-1/2''
steel deck manufacturers'
914 mm 38 mm

design equations provided in Section 1.1.8. Pre-calculated catalogs.


diaphragm shear and stiffness tables are provided in two
As shown in Figure 18, these diaphragm shear tables are
formats.
generally created with span across the heading and sidelap
36/5 36/4
Tables in Sections 1.2, 1.3 and 1.4 are in a traditional design spacing along the left margin or914/5
column. Along with other
format with diaphragm shear and stiffness
6'' values within design variables
6'' such asmm
152 deck gauge and fastener pattern, the 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
the table. tables are populated with the corresponding diaphragm shear
and stiffness values.
Tables in Section 1.6 are in a Hilti alternative format with cost
optimized Hilti frame fastener patterns, Hilti sidelap connector The Structural Engineer searches through the various
(SLC) spacings and deck gauge for a given diaphragm shear combinations until a diaphragm shear and stiffness factor is
36/7 36/5 914/7
load demand. This alternative format provides a means found that meet the design requirements.
for quick reference in order to determine6'' cost optimized 6'' 152 mm 152 mm
36'' 1-1/2'' Optimized diaphragm 36'' shear tables:
914 mmSection 1.6
1-1/2'' 38provides
mm
equivalent fastening solutions based on diaphragm shear
tables in an alternative format that helps a Structural Engineer
load only. Steel Deck Fastening Systems to quickly select a cost optimized Hilti frame fastener pattern,
In all cases, diaphragm shear values determined
1.2 Deck Fasteners for Attachment using either Hilti
tosidelap
Bar connector
Joist (SLC) spacing and deck gauge
table format are consistent. combination to satisfy the diaphragm shear load requirement
36/9 36/7 914/9
found in the left column of the table (Reference Figure 19).
These tables do not take into account other design factors,
6'' These tables are 6'' based on diaphragm shear capacity only,
152 mm 152 mm
such as gravity or wind uplift loads. These 36'' requirements
1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Allowable Stress Design (ASD) - AllowableEngineer. diaphragm stiffness must
Diaphragm Shears, SASD, (plf) and Stiffness Factors,beG',verified
(kips/in.)separately.
for
should be checked separately by the Structural
Standard 1-1/2" Deep Flutes, 6" Center-to-Center Steel Deck (Fy 33 ksi; Fu 45 ksi) Installed with Hilti X-EDN19
or X-EDNK22 Fasteners with 36/9 or 36/7 End and Interior Support Fastener Patterns1,2,3,4
Span (ft - in.)
Sidelap
4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gage Spacing Factor
36/11 Fasteners Per Sheet To Support 36/9 914/11
Hilti SLC5,6
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SASD 715 499 612 431 529 378 467 341 421 313 388 292 363 277
36" o.c. 6'' 6'' 152 mm 152 mm
G' 51.9 48.5 56.4 52.0 59.2 54.1 60.9 55.4 62.1
36'' 1-1/2'' 36'' 56.2 62.5 56.5
1-1/2''
714 mm
62.9 56.5
38 mm
SASD 765 554 666 489 596 444 534 408 488 380 455 360 430 344
24" o.c.
G' 52.9 50.2 58.1 54.5 61.6 57.5 64.1 59.6 65.8 61.0 67.1 62.1 68.0 62.9
SASD 813 607 719 545 651 501 601 469 555 445 522 426 497 410
22 18" o.c.
G' 53.8 51.5 59.5 56.5 63.7 60.2 66.7 62.9 69.0 64.9 70.9 66.7 71.9 68.0
SASD 903 706 817 649 755 610 708 580 672 558 643 540 620 526
12" o.c.
G' 55.2 53.5 61.7 59.6 66.7 64.3 70.7 68.1 74.1 70.9 76.3 73.5 78.7 75.8
SASD 1123 941 1060 902 1014 874 980 853 952 837 931 824 760 760
6" o.c. 36/11 9
G' 57.9 57.0 65.8 64.8 72.3 71.2 77.7 76.5 82.6 81.3 86.2 84.7 90.1 88.5
SASD 948 668 815 581 715 517 635 468 575 432 528 403 495 383
36" o.c.
G' 71.9 66.1 75.9 68.9 77.9 70.1 78.7 70.4 6'' 78.8 70.3 78.7 69.9 78.1 69.4 152 mm
SASD 1021 749 894 665 804 607 734 564 36'' 530
673 627 1-1/2''
502 593 481
24" o.c.
G' 73.7 68.8 78.7 72.9 81.7 75.3 83.5 76.7 84.5 77.5 84.7 78.1 85.5 78.1
Steel Deck Fastening Systems
20 18" o.c. Figure 18: Excerpt of traditional diaphragm shear and stiffness factor table
SASD 1090 825 970 745 883 690 819 649 769 618 725 594 692 574
G' 75.2 70.9 81.3 76.3 84.7 79.4 87.7 82.0 89.3 83.3 90.9 84.7 91.7 85.5
SASD 1218 964 1110 894 Optimized Diaphragm Shear Tables 1.5
1032 844 973 808 927 779 891 757 861 739
12" o.c.
G' 77.7 74.6 84.8 81.2 90.0 86.1 93.9 89.7 96.8 92.6 99.0 95.2 101.0 97.1
SASD 1522 1288 1447 1241 Span =1208
1392 4'-0'' 1350 1183 1317 1164 1222 1149 990 990
6" o.c.
G' 82.5 80.9 91.9 90.2 99.4 97.5 105.4 103.4 110.4 108.4 114.9 112.4 117.6 116.3
Allowable Recommended Hilti Powder-Actuated Frame Fastener Pattern - Sidelap Spacing Hilti SLC (in. o.c.)*
Diaphragm Design SASD 1171 831 1010 724 895 651 800 593 726 548 669 513 623 485
36" o.c.
Strength, plf* G' 109.9 X-ENP-19
99.0 111.5tf 1/4"
with 98.7 110.9 97.4X-HSN 24* with
109.3 3/16" 107.3
95.7 tf 3/8" 93.8 X-HSN
105.2 24* 91.7
with 1/8"103.1
tf < 3/16"
90.1
SASD 24" o.c.
SASD SASD 1266 935 1112 833 1003 763 921 712 855 672 798 641 752 614
(seismic) (wind) G' 22 ga.
113.6 20 ga. 116.818 ga.
104.2 105.9 16 ga. 106.3
117.7 22 ga.117.5 20 ga.
106.0 18 ga.105.3 22115.5
116.6 ga. 20 ga. 114.9 18 103.1
104.4 ga.
SASD36/3 -48
1355 36/3 1033-48 1210 937 1106
-48 870 1028 36/4 821 968
36/4 -48784 36/4920 754
36/4 -48 881 36/4 730
18272 18" o.c. 289 36/3 -48 36/3 36/3 -48 -48 -48 -48
291 309 G'36/3 -48
117.6 36/3 108.7-48 122.0 112.4 36/3
36/3 -48 123.5
-48 113.6 36/3 -30125.0 36/4
114.9
-48 125.0 36/4 -48114.9 36/4125.0
-48 114.9
36/4 -48123.536/4114.9
-48
311 331 SASD36/3 -42
1519 36/3 1211-48 1390 36/3 -481127 36/3 -48 1068
1296 36/3 -241226 36/4 -48 1171
1024 36/4 -48991 36/4 -36
1128 36/4 -48109236/4 942
964 -48
333 12" o.c.
354 G'36/3 -30
122.0 36/3 116.3-48 128.9 36/3 -48
121.7 36/3 -48 125.7
133.1 36/3 -18135.8 36/4 -48 137.6
128.3 36/4 -48130.2 36/4 -24
138.8 36/4 -48138.936/4133.3
131.6 -48
356 379 36/3
SASD -24
1519 36/3
1211-48 36/3
1390 -48
1145 36/3 -48
1296 110636/4 -30
1243 36/4 -48
1077 36/4
1205 -48
1054 36/4 -20
1175 36/4
1037 -481150 36/4 -48
1022
381 6" o.c.406 36/3 -18 36/3 -48 36/3 -48 36/3 -48 36/4 -24 36/4 -48 36/4 -48 36/4 -18 36/4 -48 36/4 -48
G' 133.3 129.9 143.6 139.9 151.5 147.6 157.5 153.6 162.2 158.4 166.0 162.4 169.5 166.7
408 434 36/3 -14 36/3 -42 36/3 -48 36/3 -48 36/4 -18 36/4 -48 36/4 -48 36/4 -14 36/4 -48 36/4 -48
437
1 Tabulated 464 shear36/4
diaphragm -20are for36/3
values -30
attachment 36/3
of -48deck to
steel 36/3 -48
base 36/4 -14 ranging
steel thicknesses 36/4 -42
from 3/16"36/4to-48 36/4
3/8". For -12
attachment 36/4 -36
to base 36/4 -48
467thicknesses
steel 497
less than 36/4
3/16",-18 36/3 shear
diaphragm -20 values36/3for
-48 36/3 -48 fasteners
the X-EDNK22 36/4 should
-12 36/4
be -30
calculated in36/4 -48
accordance 36/5 -16
with Section 36/4 -24
1.1.8 of 36/4 -42
500
this 532
Product Technical 36/4
Guide -14
Supplement. 36/3 -18 36/3 -36 36/3 -42 36/5 -18 36/4 -24 36/4 -48 36/5 -14 36/4 -20 36/4 -36
535 569 36/4 -12 36/4 -24 36/3 -24 36/3 -30 36/5 -14 36/4 -20 36/4 -42 36/9 -48 36/4 -18 36/4 -24
2 Tabulated ASD diaphragm shear loads are calculated with a safety factor () of 2.35 for wind loads. To calculate ASD values for load combinations
572 609 36/5 -16 36/4 -20 36/3 -20 36/3 -24 36/5 -12 36/4 -16 36/4 -30 36/9 -48 36/4 -14 36/4 -20
involving earthquake, multiply values in table by 2.35 and divide by a safety factor () of 2.50. Panel buckling has been checked.
612 651 36/5 -14 36/4 -18 36/3 -16 36/3 -18 36/9 -48 36/4 -14 36/4 -24 36/9 -30 36/4 -12 36/4 -18
3 At 655
diaphragm perimeter,
697 Hilti frame
36/5 -10 fasteners should
36/4 -14 be spaced
36/4 -24 at identical
36/3 -14spacing as sidelap
36/5 -8 connectors.
36/5 -20 36/4 -20 36/9 -20 36/5 -18 36/4 -14
4 Interpolation
701 of diaphragm
746 shear
36/5 -8 Figure 19: Excerpt of optimized diaphragm shear table
strengths and
36/4 stiffness
-12 factors
36/4 -20 is allowed between36/9
36/4 -24 span-24dimensions, sidelap 36/4
36/5 -16 spacings
-18 and36/9deck-16
gauge. 36/5 -14 36/4 -12
750
Alternatively, use798
calculations36/5
as -7
discussed36/5in-16 36/4 -18
Section 1.1.8 36/4 diaphragm
to determine -18 36/9 -18 strengths
shear 36/5 -12 36/5 factors
and stiffness -24 36/9 -12
directly. 36/5 -12 36/5 -18
5 To802
convert from854 36/9 -24
sidelap spacing 36/5 -14per span
(SS) to sidelaps 36/4(SPS),
-14 use36/4 -16
the following 36/9 -14 SPS=((span,
formula: 36/9 -48 ft) x 12)/(SS,
36/5 -20in.). Round
36/9 -10 36/9
up to the next-42 36/5 -14
859 914
whole sidelap connector. 36/9 -18 36/5 -10 36/5 -20 36/4 -12 36/9 -10 36/9 -42 36/9 -48 36/9 -8 36/9 -30 36/5 -12
919 977 36/9 -12 36/5 -8 36/5 -16 36/5 -18 36/9 -8 36/9 -24 36/7 -20 36/9 -7 36/9 -20 36/7 -16
6 For 18 gauge deck use S-SLC 02 M HWH. More information on Hilti Sidelap Connectors (SLC) can be found in Section 1.4.
983
24 Hilti, Inc. (US) 1-800-879-8000 |1046 36/9 -10
www.us.hilti.com I 36/5 -7
en espaol 36/5 -14
1-800-879-5000 36/5 -14
I Hilti36/9 -7
(Canada) 36/9 -20
Corp. 36/9 -48
1-800-363-4458 36/11-8
I www.hilti.ca36/9 -16
I PTG36/9 -24
Decking Supplement 2014
1052 1119 36/9 -8 36/5 -6 36/5 -10 36/5 -12 36/9 -6 36/9 -16 36/9 -48 36/11-7 36/9 -12 36/9 -20
1126 1197 36/9 -7 36/9 -16 36/5 -8 36/5 -10 36/11-7 36/9 -12 36/9 -30 36/11-6 36/9 -10 36/7 -10
1204 1281 36/9 -5 36/9 -12 36/5 -7 36/5 -8 36/11-6 36/9 -10 36/9 -20 36/9 -8 36/9 -12
Steel Deck Fastening Systems

X-HSN 24 for Fastening Deck to Bar Joist 1.2

1.2.1 Product Description 1.2.1 Product Description

The Hilti bar joist deck fastening system into the DX 860-HSN tool, along with the 1.2.2 Material Specifications
consists of powder-actuated tools that cartridge strip, and enable the operator 1.2.3 Technical Data
are primarily used with the X-HSN 24 to fasten at a rate of up to 1,000 quality 1.2.4 Ordering Information
fasteners, which are available in a fastenings per hour. Additionally, this
collated version. tool offers punch through resistance
in cases where the base material is
For many bar joist decking projects, the
inadvertently missed.
tool of choice is the DX 860-HSN tool.
This self-contained stand up decking Other tools include the hand held
tool is powered by 0.27 caliber short DX 460-SM, a semi-automatic magazine
cartridges, which are loaded into the tool for use on smaller jobs or in tandem
tool in strips of 40. The cartridges drive with the DX 860-HSN.
the X-HSN 24 fasteners into almost
Hilti X-HSN 24 steel deck fasteners
any type of steel deck profile and base
comply with ANSI/SDI RD1.0, C1.0
steel thicknesses of 1/8" to 3/8". These X-HSN 24
and NC1.0 standards.
fasteners are available in collated strips
of 10. Four of these strips are loaded Approvals/Listings
ICC-ES (International Code Council)
ESR-3592, ESR-2776, ESR-2197,
1.2.2 Material Specifications ESR-1116, ESR-1735P, ESR-1414,
Fastener Fastener Fastener Nominal fastener ESR-2408
designation material plating hardness COLA (City of Los Angeles)
Carbon Steel 5 m Zinc1
RR 25974, RR 25877, RR 25296
X-HSN 24 55.5 HRC
FM (Factory Mutual)
1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide For attaching Class 1 Steel Roof Decks
Volume 1: Direct Fastening for more information. with 1-60 and 1-90 wind uplift ratings.
Refer to FM RoofNav for specific
1.2.3 Technical Data assembly listings.
UL (Underwriters Laboratories)
Allowable pullout loads for attachments to steel base material lb (kN)1, 2, 3
Fasteners for attaching steel roof deck
Base material thickness (in.) (uplift and fire classification)
Fastener
1/8 3/16 1/4 3/8
X-HSN 24 435 (1.95) 635 (2.82) 750 (3.34) 750 (3.34)
1 These values represent testing performed in ASTM A36 plate steel.
2 The values must be compared with allowable tensile pullover values.
3 Allowable values based on safety factor of 5.0.

Allowable pullover and shear bearing loads for attaching steel deck1,2,3

Steel deck gauge (in.)


16 (0.0598) 18 (0.0474) 20 (0.0358) 22 (0.0295) 24 (0.0239) 26 (0.0179)
Fastener
Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear
lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
865 975 725 785 560 600 500 500 450 410 415 310
X-HSN 241
(3.85) (4.29) (3.22) (3.45) (2.49) (2.64) (2.22) (2.20) (2.00) (1.80) (1.85) (1.36)
1 For base steel thickness 1/8" (3 mm) to 3/8" (10 mm).
2 Allowable values are based on a safety factor of 3.0.
3 Loads based on ASTM A1008, or minimum ASTM A653 SQ33 steel deck.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 25
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

1.2 X-HSN 24 for Fastening Deck to Bar Joist

36/9 36/7 914/9

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for
standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti X-HSN 24
fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/11 36/9 914/11
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SASD 715 499 612 431 529 378 467 341 421 313 388 292 363 277
36" O.C.
6''
G' 51.9 48.5 56.4 52.0 59.2 54.1 60.9 6''
55.4 62.0152 56.0
mm 62.5 56.4 62.7 56.5
36'' 1-1/2''
SASD 36'' 765 554 666 1-1/2''
489 596 444 534 408 488 380 455 714360mm 430 344 38 mm
24" O.C.
G' 52.9 50.2 58.1 54.5 61.6 57.5 64.1 59.6 65.8 61.1 67.0 62.1 67.9 62.9
SASD 813 607 719 545 651 501 601 469 555 445 522 426 497 410
18" O.C.
G' 53.8 51.5 59.5 56.5 63.6 60.2 66.7 63.0 69.0 65.1 70.7 66.8 72.1 68.1
22
SASD 903 706 817 649 755 610 708 580 672 558 643 540 620 526
12" O.C.
G' 55.2 53.5 61.7 59.6 66.7 64.3 70.7 68.1 73.8 71.1 76.4 73.6 78.6 75.7
SASD 1123 941 1060 902 1014 874 980 853 952 837 931 824 760 760
6" O.C. 36/11
G' 57.9 57.0 65.8 64.8 72.3 71.2 77.7 76.5 82.4 81.1 86.3 85.1 89.8 88.5
SASD 1394 1211 1362 1193 1338 1180 1321 1170 1188 1163 938 938 760 760
3" O.C.
G' 60.3 60.0 69.4 69.0 77.1 76.7 83.8 6''
83.3 89.5 89.1 94.6 94.1 99.1 98.6
36'' 1-1/2''
SASD 948 668 815 581 715 517 635 468 575 432 528 403 495 383
36" O.C.
G' 71.9 66.1 75.9 68.9 77.9 70.1 78.7 70.4 78.8 70.3 78.5 69.9 77.9 69.3
SASD 1021 749 894 665 804 607 734 564 673 530 627 502 593 481
24" O.C.
G' 73.7 68.8 78.7 72.9 81.7 75.3 83.5 76.7 84.5 77.5 85.1 78.0 85.3 78.2
SASD 1090 825 970 745 883 690 819 649 769 618 725 594 692 574
18" O.C.
G' 75.2 71.1 81.0 76.1 84.9 79.5 87.5 81.8 89.3 83.5 90.5 84.7 91.4 85.5
20
SASD 1218 964 1110 894 1032 844 973 808 927 779 891 757 861 739
12" O.C.
G' 77.7 74.6 84.8 81.2 90.0 86.1 93.9 89.7 96.8 92.6 99.1 94.9 100.9 96.7
SASD 1522 1288 1447 1241 1392 1208 1350 1183 1317 1164 1222 1149 990 990
6" O.C.
G' 82.5 80.9 91.9 90.2 99.4 97.5 105.4 103.4 110.4 108.4 114.6 112.6 118.1 116.1
SASD 1873* 1630 1838* 1611 1812* 1597 1793* 1587 1547 1547 1222 1222 990 990
3" O.C.
G' 87.1 86.4 98.5 97.8 107.8 107.1 115.7 114.9 122.4 121.6 128.1 127.3 133.1 132.3
SASD 1171 831 1010 724 895 651 800 593 726 548 669 513 623 485
36" O.C.
G' 110.2 98.7 111.6 98.8 111.0 97.5 109.4 95.7 107.4 93.8 105.2 92.0 103.1 90.2
SASD 1266 935 1112 833 1003 763 921 712 855 672 798 641 752 614
24" O.C.
G' 113.8 104.0 116.9 106.0 117.8 106.4 117.5 106.0 116.7 105.3 115.6 104.4 114.4 103.6
SASD 1355 1033 1210 937 1106 870 1028 821 968 784 920 754 881 730
18" O.C.
G' 117.1 108.5 121.5 112.1 123.6 113.8 124.5 114.7 124.7 115.0 124.5 115.0 124.1 114.8
18
SASD 1519 1211 1390 1127 1296 1068 1226 1024 1171 991 1128 964 1092 942
12" O.C.
G' 122.4 115.8 129.0 121.8 133.2 125.8 135.9 128.4 137.7 130.3 138.9 131.7 139.7 132.7
SASD 1902 1616 1814 1562 1750 1524 1702 1496 1664 1474 1633 1456 1420 1420
6" O.C.
G' 133.0 129.5 143.7 139.9 151.6 147.7 157.6 153.8 162.3 158.6 166.2 162.5 169.3 165.7
SASD 2328* 2027 2289* 2006 2260* 1991 2239 1980 2219 1971 1753 1753 1420 1420
3" O.C.
G' 143.6 142.1 157.9 156.3 169.1 167.5 178.1 176.5 185.5 183.9 191.6 190.1 196.8 195.4
SASD 1297 923 1120 807 995 726 897 667 816 617 753 579 703 548
36" O.C.
G' 148.7 130.5 146.3 127.0 142.3 122.9 137.9 118.9 133.7 115.3 129.7 112.0 126.0 109.1
SASD 1405 1042 1237 931 1117 855 1028 798 960 755 901 721 851 694
24" O.C.
G' 154.8 138.9 154.5 137.7 152.3 135.6 149.6 133.2 146.7 130.8 143.9 128.7 141.2 126.7
SASD 1506 1153 1348 1049 1234 977 1150 923 1084 882 1032 850 989 824
18" O.C.
G' 160.1 146.1 161.6 147.0 161.1 146.5 159.7 145.5 158.0 144.2 156.2 143.0 154.5 141.8
16
SASD 1692 1355 1552 1265 1451 1201 1374 1153 1315 1117 1268 1088 1229 1065
12" O.C.
G' 169.1 158.0 173.6 162.2 175.7 164.3 176.6 165.5 176.8 166.1 176.7 166.4 176.3 166.5
SASD 2120 1806 2027 1750 1959 1709 1908 1679 1867 1656 1835 1638 1775 1623
6" O.C.
G' 187.5 181.3 197.8 191.5 205.0 198.7 210.1 204.1 214.0 208.2 217.0 211.4 219.4 214.1
SASD 2585 2251 2544 2230 2515 2215 2493 2203 2476 2195 2191 2188 1775 1775
3" O.C.
G' 206.5 203.7 222.3 219.5 234.2 231.5 243.4 240.8 250.7 248.2 256.7 254.3 261.7 259.4
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" tf 3/8". For attachment to base steel with range
1/8" tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
*For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19).

26 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

X-HSN 24 for Fastening Deck to Bar Joist 1.2

36/5 36/4 914/5

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for
standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti X-HSN 24
fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/7 36/5 914/7
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SASD 448 365 393 325 354 296 325 275 299 257 280 242 265 232
36" O.C. 6'' 152 mm
6''
G' 13.2 9.7 15.8 11.6 18.1 13.4 20.1 15.1 21.9 16.6 23.5 18.0 24.9 19.2
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SASD 495 407 444 372 408 346 380 327 359 312 343 300 329 290
24" O.C.
G' 13.4 9.8 16.1 11.8 18.5 13.7 20.7 15.5 22.7 17.2 24.6 18.8 26.3 20.2
SASD 537 445 491 414 457 391 432 374 412 360 397 350 384 341
18" O.C.
G' 13.5 9.8 16.3 12.0 18.8 14.0 21.2 15.8 23.4 17.6 25.4 19.3 27.2 20.9
22
SASD 612 508 573 484 545 466 524 453 507 442 494 434 483 427
12" O.C.
G' 13.7 9.9 16.6 12.1 19.3 14.2 21.8 16.2 24.2 18.1 26.4 20.0 28.5 21.7
SASD 766 623 744 611 729 603 717 597 707 592 700 588 694 585
6" O.C. 36/9 36/7 914/9
G' 13.9 10.1 17.0 12.4 19.9 14.6 22.7 16.8 25.3 18.8 27.8 20.8 30.3 22.8
SASD 766 623 744 611 729 603 717 597 707 592 700 588 694 585
3" O.C. 6'' 6'' 152 mm
G' 14.1 10.2 17.3 12.6 20.3 14.9 23.3 17.1 26.1 19.3 28.8 21.4 31.4 23.4
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SASD 600 490 530 439 479 403 442 376 413 355 387 338 368 324
36" O.C.
G' 20.4 15.0 23.9 17.8 26.9 20.3 29.4 22.5 31.6 24.5 33.5 26.2 35.1 27.8
SASD 666 550 602 506 556 474 522 450 495 431 474 416 456 404
24" O.C.
G' 20.7 15.2 24.4 18.2 27.8 21.0 30.7 23.4 33.3 25.7 35.6 27.7 37.6 29.6
SASD 727 603 668 564 626 536 595 515 570 499 551 485 535 475
18" O.C.
G' 20.9 15.4 24.9 18.5 28.4 21.4 31.6 24.1 34.5 26.5 37.1 28.8 39.5 30.9
20
SASD 830 688 783 659 748 638 722 622 702 610 686 600 673 592
12" O.C. 36/11 36/9 914/11
G' 21.3 15.6 25.5 18.9 29.3 22.0 32.9 24.9 36.1 27.6 39.1 30.2 41.9 32.6
SASD 1032 834 1008 822 990 813 977 806 967 801 958 797 951 794
6" O.C. 6'' 6'' 152 mm
G' 21.8 16.0 26.4 19.5 30.7 22.8 34.7 26.0 38.5 29.1 42.1 32.0 45.4 34.8
36'' 1-1/2'' 36'' 714 mm1-1/2'' 38 mm
SASD 1032 834 1008 822 990 813 977 806 967 801 958 797 951 794
3" O.C.
G' 22.2 16.2 27.1 19.9 31.6 23.4 36.0 26.8 40.1 30.0 44.0 33.2 47.8 36.2
SASD 745 609 660 549 599 505 554 473 519 447 492 427 467 411
36" O.C.
G' 36.7 27.6 41.7 31.9 45.7 35.5 48.7 38.4 51.1 40.9 53.0 42.9 54.5 44.7
SASD 830 687 753 634 698 596 657 567 624 545 599 527 578 512
24" O.C.
G' 37.6 28.3 43.3 33.1 47.9 37.2 51.8 40.8 55.0 43.9 57.7 46.6 60.0 49.0
SASD 907 753 838 708 788 675 750 650 721 631 698 615 678 602
18" O.C. 36/11
G' 38.3 28.8 44.5 33.9 49.7 38.5 54.1 42.5 57.9 46.0 61.2 49.2 64.1 52.1
18
SASD 1037 859 982 826 942 802 912 783 888 769 869 757 853 748
12" O.C. 6''
G' 39.4 29.5 46.2 35.1 52.1 40.2 57.4 44.8 62.0 48.9 66.2 52.8 69.9 56.3
36'' 1-1/2''
SASD 1285 1034 1258 1021 1238 1011 1223 1004 1211 998 1202 994 1194 990
6" O.C.
G' 41.0 30.6 48.8 36.8 55.9 42.6 62.4 48.0 68.3 53.1 73.7 57.8 78.7 62.3
SASD 1285 1034 1258 1021 1238 1011 1223 1004 1211 998 1202 994 1194 990
3" O.C.
G' 42.3 31.3 50.8 38.0 58.7 44.3 66.0 50.3 72.8 55.9 79.1 61.2 85.0 66.3
SASD 827 678 735 612 669 565 619 529 581 502 551 480 527 462
36" O.C.
G' 57.6 44.2 63.4 49.6 67.5 53.8 70.3 56.9 72.3 59.4 73.6 61.3 74.6 62.8
SASD 924 765 841 708 781 667 736 636 701 612 673 593 650 577
24" O.C.
G' 59.6 45.7 66.6 52.2 72.0 57.3 76.1 61.6 79.3 65.1 81.8 68.0 83.8 70.5
SASD 1011 840 936 791 882 756 842 729 810 708 785 691 764 678
18" O.C.
G' 61.2 46.9 69.2 54.0 75.5 60.0 80.6 65.1 84.8 69.4 88.2 73.1 91.1 76.3
16
SASD 1156 957 1098 922 1055 897 1022 877 997 862 977 850 960 840
12" O.C.
G' 63.6 48.6 72.9 56.7 80.7 63.8 87.2 70.0 92.8 75.4 97.6 80.3 101.8 84.6
SASD 1428 1146 1400 1133 1380 1123 1364 1116 1352 1110 1342 1106 1334 1102
6" O.C.
G' 67.5 51.2 78.9 60.8 89.0 69.5 97.8 77.3 105.7 84.5 112.7 91.1 119.0 97.1
SASD 1428 1146 1400 1133 1380 1123 1364 1116 1352 1110 1342 1106 1334 1102
3" O.C.
G' 70.6 53.1 83.6 63.8 95.3 73.5 105.9 82.6 115.5 91.0 124.3 98.8 132.3 106.1
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" tf 3/8". For attachment to base steel with range
1/8" tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads..
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 27
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

1.2 X-HSN 24 for Fastening Deck to Bar Joist

36/9 36/7 914/9

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
X-HSN 24 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/11 36/9 914/11
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SLRFD 1174 820 1005 708 869 622 768 560 692 514 638 481 596 455
36" O.C. 6''
6''
G' 51.9 48.5 56.4 52.0 59.2 54.1 60.9 55.4 62.0152 56.0
mm 62.5 56.4 62.7 56.5
36'' 1-1/2'' 36'' 1-1/2''
714 mm 38 mm
SLRFD 1257 911 1095 803 979 729 878 671 802 624 748 591 706 565
24" O.C.
G' 52.9 50.2 58.1 54.5 61.6 57.5 64.1 59.6 65.8 61.1 67.0 62.1 67.9 62.9
SLRFD 1336 998 1181 895 1070 824 987 771 912 731 858 700 817 674
18" O.C.
G' 53.8 51.5 59.5 56.5 63.6 60.2 66.7 63.0 69.0 65.1 70.7 66.8 72.1 68.1
22
SLRFD 1484 1159 1342 1067 1240 1002 1164 954 1104 917 1057 888 1019 864
12" O.C.
G' 55.2 53.5 61.7 59.6 66.7 64.3 70.7 68.1 73.8 71.1 76.4 73.6 78.6 75.7
SLRFD 1846 1547 1742 1482 1667 1436 1610 1402 1565 1375 1501 1354 1216 1216
6" O.C. 36/11
G' 57.9 57.0 65.8 64.8 72.3 71.2 77.7 76.5 82.4 81.1 86.3 85.1 89.8 88.5
SLRFD 2291 1990 2238 1960 2199 1939 2170 1923 1900 1900 1501 1501 1216 1216
3" O.C. 6''
G' 60.3 60.0 69.4 69.0 77.1 76.7 83.8 83.3 89.5 89.1 94.6 94.1 99.1 98.6
36'' 1-1/2''
SLRFD 1558 1098 1339 954 1175 850 1044 770 945 710 868 663 813 629
36" O.C.
G' 71.9 66.1 75.9 68.9 77.9 70.1 78.7 70.4 78.8 70.3 78.5 69.9 77.9 69.3
SLRFD 1678 1230 1469 1093 1321 997 1206 927 1107 872 1030 825 975 791
24" O.C.
G' 73.7 68.8 78.7 72.9 81.7 75.3 83.5 76.7 84.5 77.5 85.1 78.0 85.3 78.2
SLRFD 1791 1355 1593 1225 1451 1134 1346 1067 1264 1016 1192 975 1137 943
18" O.C.
G' 75.2 71.1 81.0 76.1 84.9 79.5 87.5 81.8 89.3 83.5 90.5 84.7 91.4 85.5
20
SLRFD 2001 1585 1823 1469 1695 1387 1599 1327 1524 1281 1464 1244 1415 1214
12" O.C.
G' 77.7 74.6 84.8 81.2 90.0 86.1 93.9 89.7 96.8 92.6 99.1 94.9 100.9 96.7
SLRFD 2501 2116 2377 2039 2287 1985 2218 1944 2165 1913 1956 1888 1584 1584
6" O.C.
G' 82.5 80.9 91.9 90.2 99.4 97.5 105.4 103.4 110.4 108.4 114.6 112.6 118.1 116.1
SLRFD 3078* 2679 3020* 2647 2978* 2625 2946* 2608 2475 2475 1956 1956 1584 1584
3" O.C.
G' 87.1 86.4 98.5 97.8 107.8 107.1 115.7 114.9 122.4 121.6 128.1 127.3 133.1 132.3
SLRFD 1925 1365 1660 1190 1471 1069 1314 974 1193 900 1099 843 1024 797
36" O.C.
G' 110.2 98.7 111.6 98.8 111.0 97.5 109.4 95.7 107.4 93.8 105.2 92.0 103.1 90.2
SLRFD 2080 1536 1828 1370 1648 1254 1514 1169 1405 1105 1311 1053 1236 1009
24" O.C.
G' 113.8 104.0 116.9 106.0 117.8 106.4 117.5 106.0 116.7 105.3 115.6 104.4 114.4 103.6
SLRFD 2227 1697 1988 1540 1817 1430 1689 1350 1590 1288 1511 1239 1447 1200
18" O.C.
G' 117.1 108.5 121.5 112.1 123.6 113.8 124.5 114.7 124.7 115.0 124.5 115.0 124.1 114.8
18
SLRFD 2496 1990 2283 1852 2130 1755 2014 1683 1925 1628 1853 1584 1795 1549
12" O.C.
G' 122.4 115.8 129.0 121.8 133.2 125.8 135.9 128.4 137.7 130.3 138.9 131.7 139.7 132.7
SLRFD 3125 2655 2981 2567 2876 2504 2796 2458 2734 2421 2684 2393 2272 2272
6" O.C.
G' 133.0 129.5 143.7 139.9 151.6 147.7 157.6 153.8 162.3 158.6 166.2 162.5 169.3 165.7
SLRFD 3825* 3331 3761* 3296 3714* 3272 3679 3254 3550 3240 2805 2805 2272 2272
3" O.C.
G' 143.6 142.1 157.9 156.3 169.1 167.5 178.1 176.5 185.5 183.9 191.6 190.1 196.8 195.4
SLRFD 2131 1517 1841 1326 1635 1193 1474 1095 1341 1014 1238 952 1155 901
36" O.C.
G' 148.7 130.5 146.3 127.0 142.3 122.9 137.9 118.9 133.7 115.3 129.7 112.0 126.0 109.1
SLRFD 2308 1712 2033 1531 1836 1404 1690 1312 1577 1241 1481 1185 1398 1140
24" O.C.
G' 154.8 138.9 154.5 137.7 152.3 135.6 149.6 133.2 146.7 130.8 143.9 128.7 141.2 126.7
SLRFD 2475 1895 2215 1724 2028 1605 1889 1517 1781 1450 1695 1397 1626 1354
18" O.C.
G' 160.1 146.1 161.6 147.0 161.1 146.5 159.7 145.5 158.0 144.2 156.2 143.0 154.5 141.8
16
SLRFD 2780 2227 2550 2078 2384 1973 2259 1895 2161 1835 2084 1788 2020 1750
12" O.C.
G' 169.1 158.0 173.6 162.2 175.7 164.3 176.6 165.5 176.8 166.1 176.7 166.4 176.3 166.5
SLRFD 3484 2968 3331 2875 3219 2809 3135 2760 3068 2721 3015 2691 2840 2666
6" O.C.
G' 187.5 181.3 197.8 191.5 205.0 198.7 210.1 204.1 214.0 208.2 217.0 211.4 219.4 214.1
SLRFD 4247 3699 4181 3664 4133 3639 4097 3621 4068 3606 3506 3506 2840 2840
3" O.C.
G' 206.5 203.7 222.3 219.5 234.2 231.5 243.4 240.8 250.7 248.2 256.7 254.3 261.7 259.4
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" tf 3/8". For attachment to base steel with range
1/8" tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
*For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19) of this document

28 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

X-HSN 24 for Fastening Deck to Bar Joist 1.2

36/5 36/4 914/5

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
X-HSN 24 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/7 36/5 914/7
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SLRFD 737 599 646 534 582 487 534 452 491 422 460 398 436 381
36" O.C. 6'' 152 mm
6''
G' 13.2 9.7 15.8 11.6 18.1 13.4 20.1 15.1 21.9 16.6 23.5 18.0 24.9 19.2
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SLRFD 813 669 729 611 670 569 625 537 590 513 563 493 540 477
24" O.C.
G' 13.4 9.8 16.1 11.8 18.5 13.7 20.7 15.5 22.7 17.2 24.6 18.8 26.3 20.2
SLRFD 883 732 806 680 751 643 710 614 678 592 652 574 631 560
18" O.C.
G' 13.5 9.8 16.3 12.0 18.8 14.0 21.2 15.8 23.4 17.6 25.4 19.3 27.2 20.9
22
SLRFD 1006 835 942 795 896 766 861 744 833 726 811 712 793 701
12" O.C.
G' 13.7 9.9 16.6 12.1 19.3 14.2 21.8 16.2 24.2 18.1 26.4 20.0 28.5 21.7
SLRFD 1259 1023 1223 1005 1197 991 1178 981 1162 973 1150 967 1140 962
6" O.C. 36/9 36/7 914/9
G' 13.9 10.1 17.0 12.4 19.9 14.6 22.7 16.8 25.3 18.8 27.8 20.8 30.3 22.8
SLRFD 1259 1023 1223 1005 1197 991 1178 981 1162 973 1150 967 1140 962
3" O.C. 6'' 6'' 152 mm
G' 14.1 10.2 17.3 12.6 20.3 14.9 23.3 17.1 26.1 19.3 28.8 21.4 31.4 23.4
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SLRFD 985 805 870 722 788 662 727 618 679 583 636 556 605 532
36" O.C.
G' 20.4 15.0 23.9 17.8 26.9 20.3 29.4 22.5 31.6 24.5 33.5 26.2 35.1 27.8
SLRFD 1095 904 989 831 914 779 857 739 813 708 778 684 750 663
24" O.C.
G' 20.7 15.2 24.4 18.2 27.8 21.0 30.7 23.4 33.3 25.7 35.6 27.7 37.6 29.6
SLRFD 1194 991 1098 928 1029 882 977 847 937 820 905 798 878 780
18" O.C.
G' 20.9 15.4 24.9 18.5 28.4 21.4 31.6 24.1 34.5 26.5 37.1 28.8 39.5 30.9
20
SLRFD 1364 1131 1286 1083 1230 1049 1187 1023 1154 1002 1127 986 1105 972
12" O.C. 36/11 36/9 914/11
G' 21.3 15.6 25.5 18.9 29.3 22.0 32.9 24.9 36.1 27.6 39.1 30.2 41.9 32.6
SLRFD 1696 1370 1656 1350 1628 1336 1606 1325 1588 1317 1574 1310 1563 1304
6" O.C. 6'' 6'' 152 mm
G' 21.8 16.0 26.4 19.5 30.7 22.8 34.7 26.0 38.5 29.1 42.1 32.0 45.4 34.8
36'' 1-1/2'' 36'' 714 mm1-1/2'' 38 mm
SLRFD 1696 1370 1656 1350 1628 1336 1606 1325 1588 1317 1574 1310 1563 1304
3" O.C.
G' 22.2 16.2 27.1 19.9 31.6 23.4 36.0 26.8 40.1 30.0 44.0 33.2 47.8 36.2
SLRFD 1224 1001 1084 902 985 830 911 777 853 735 808 702 768 675
36" O.C.
G' 36.7 27.6 41.7 31.9 45.7 35.5 48.7 38.4 51.1 40.9 53.0 42.9 54.5 44.7
SLRFD 1364 1128 1238 1042 1147 979 1079 932 1026 895 984 866 950 842
24" O.C.
G' 37.6 28.3 43.3 33.1 47.9 37.2 51.8 40.8 55.0 43.9 57.7 46.6 60.0 49.0
SLRFD 1490 1238 1377 1163 1295 1109 1233 1068 1185 1036 1146 1010 1115 989
18" O.C. 36/11
G' 38.3 28.8 44.5 33.9 49.7 38.5 54.1 42.5 57.9 46.0 61.2 49.2 64.1 52.1
18
SLRFD 1704 1411 1614 1357 1548 1317 1498 1287 1459 1264 1427 1245 1402 1229
12" O.C. 6''
G' 39.4 29.5 46.2 35.1 52.1 40.2 57.4 44.8 62.0 48.9 66.2 52.8 69.9 56.3
36'' 1-1/2''
SLRFD 2111 1699 2067 1677 2034 1662 2010 1650 1991 1640 1975 1633 1962 1627
6" O.C.
G' 41.0 30.6 48.8 36.8 55.9 42.6 62.4 48.0 68.3 53.1 73.7 57.8 78.7 62.3
SLRFD 2111 1699 2067 1677 2034 1662 2010 1650 1991 1640 1975 1633 1962 1627
3" O.C.
G' 42.3 31.3 50.8 38.0 58.7 44.3 66.0 50.3 72.8 55.9 79.1 61.2 85.0 66.3
SLRFD 1359 1114 1207 1005 1099 928 1018 869 955 824 906 788 865 759
36" O.C.
G' 57.6 44.2 63.4 49.6 67.5 53.8 70.3 56.9 72.3 59.4 73.6 61.3 74.6 62.8
SLRFD 1518 1257 1382 1164 1283 1096 1209 1045 1152 1005 1106 974 1069 948
24" O.C.
G' 59.6 45.7 66.6 52.2 72.0 57.3 76.1 61.6 79.3 65.1 81.8 68.0 83.8 70.5
SLRFD 1661 1380 1538 1300 1450 1242 1383 1198 1331 1164 1290 1136 1256 1114
18" O.C.
G' 61.2 46.9 69.2 54.0 75.5 60.0 80.6 65.1 84.8 69.4 88.2 73.1 91.1 76.3
16
SLRFD 1900 1572 1804 1515 1733 1473 1680 1441 1638 1416 1605 1396 1578 1380
12" O.C.
G' 63.6 48.6 72.9 56.7 80.7 63.8 87.2 70.0 92.8 75.4 97.6 80.3 101.8 84.6
SLRFD 2347 1884 2301 1862 2267 1846 2242 1834 2222 1824 2206 1817 2193 1810
6" O.C.
G' 67.5 51.2 78.9 60.8 89.0 69.5 97.8 77.3 105.7 84.5 112.7 91.1 119.0 97.1
SLRFD 2347 1884 2301 1862 2267 1846 2242 1834 2222 1824 2206 1817 2193 1810
3" O.C.
G' 70.6 53.1 83.6 63.8 95.3 73.5 105.9 82.6 115.5 91.0 124.3 98.8 132.3 106.1
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" tf 3/8". For attachment to base steel with range
1/8" tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 29
6'' 152 mm
36'' 914 mm
1-1/2'' 38 mm 914 mm 38 mm

Steel Deck Fastening Systems

1.2 X-HSN 24 for Fastening Deck to Bar Joist


c
36/7 914/9 (36/9)
914/9 914/7 (36/7)
914/7

6'' 152 mm 152 mm


36'' 914 mm
1-1/2'' 38 mm 914 mm 38 mm
Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
X-HSN 24 fasteners with 914/9 (36/9) or 914/7 (36/7) end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti36/9
SLC6,7,8 Fasteners per sheet to support
914/11 914/9
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SLSD 16.1 11.3 13.8 9.7 12.0 8.6 10.6 7.7 9.5 7.1 8.8 6.6 8.2 6.3
900
6''mm
152O.C.
mm G' 9.0 8.5 9.8 9.1 10.3 9.5 152 mm
10.7 9.7 10.9 9.8 11.0 9.9 11.0 9.9
36'' 714 mm 1-1/2'' 38 mm 914 mm 38 mm
SLSD 17.3 12.5 15.0 11.0 13.5 10.0 12.1 9.2 11.1 8.6 10.3 8.1 9.7 7.8
600 mm O.C..
G' 9.2 8.7 10.1 9.5 10.8 10.1 11.2 10.4 11.5 10.7 11.7 10.9 11.9 11.0
SLSD 18.3 13.7 16.2 12.3 14.7 11.3 13.6 10.6 12.6 10.1 11.8 9.6 11.2 9.3
450 mm O.C.
G' 9.4 9.0 10.4 9.9 11.1 10.5 11.6 11.0 12.1 11.4 12.4 11.7 12.6 11.9
22
SLSD 20.3 15.9 18.4 14.6 17.0 13.8 16.0 13.1 15.2 12.6 14.5 12.2 14.0 11.9
300 mm O.C.
G' 9.6 9.3 10.7 10.4 11.6 11.2 12.3 11.9 12.9 12.4 13.4 12.9 13.8 13.3
SLSD 25.3 21.2 23.9 20.3 22.8 19.7 22.1 19.2 21.4 18.8 21.0 18.6 17.2 17.2
150 36/11
mm O.C. 914/11
G' 10.0 9.9 11.4 11.3 12.6 12.4 13.5 13.3 14.4 14.1 15.1 14.8 15.7 15.5
SLSD 31.2* 27.1 30.5 26.7 30.0 26.4 29.6 26.2 26.8 26.1 21.2 21.2 17.2 17.2
75
6''mm O.C. 152 mm
G' 10.5 10.4 12.0 12.0 13.4 13.3 14.6 14.5 15.6 15.5 16.5 16.4 17.3 17.2
36'' 1-1/2'' 714 mm 38 mm
SLSD 21.4 15.1 18.4 13.1 16.2 11.7 14.4 10.6 13.0 9.8 12.0 9.1 11.2 8.7
900 mm O.C.
G' 12.5 11.5 13.3 12.1 13.6 12.3 13.8 12.4 13.8 12.4 13.8 12.3 13.7 12.2
SLSD 23.0 16.9 20.2 15.0 18.1 13.7 16.6 12.8 15.3 12.0 14.2 11.4 13.4 10.9
600 mm O.C.
G' 12.8 12.0 13.7 12.7 14.3 13.2 14.6 13.5 14.8 13.6 14.9 13.7 15.0 13.8
SLSD 24.6 18.6 21.9 16.8 19.9 15.6 18.5 14.7 17.4 14.0 16.4 13.4 15.7 13.0
450 mm O.C.
G' 13.1 12.4 14.2 13.3 14.9 13.9 15.3 14.3 15.7 14.6 15.9 14.9 16.0 15.0
20
SLSD 27.4 21.7 25.0 20.2 23.3 19.0 21.9 18.2 20.9 17.6 20.1 17.1 19.4 16.7
300 mm O.C.
G' 13.5 13.0 14.8 14.2 15.7 15.0 16.4 15.7 17.0 16.2 17.4 16.6 17.7 17.0
SLSD 34.2 28.9 32.5 27.9 31.3 27.2 30.4 26.6 29.6 26.2 27.6 25.8 22.4 22.4
150 mm O.C.
G' 14.4 14.1 16.0 15.7 17.3 17.0 18.4 18.1 19.3 18.9 20.0 19.7 20.7 20.3
SLSD 41.9* 36.5 41.2* 36.1 40.6* 35.8 40.2* 35.5 35.0 35.0 27.6 27.6 22.4 22.4
75 mm O.C.
G' 15.1 15.0 17.1 17.0 18.8 18.6 20.2 20.0 21.3 21.2 22.3 22.2 23.2 23.1
SLSD 26.4 18.8 22.8 16.4 20.2 14.7 18.1 13.4 16.4 12.4 15.2 11.6 14.1 11.0
900 mm O.C.
G' 19.3 17.3 19.6 17.3 19.5 17.2 19.2 16.9 18.9 16.5 18.5 16.2 18.2 15.9
SLSD 28.5 21.1 25.1 18.8 22.6 17.2 20.8 16.1 19.4 15.2 18.1 14.5 17.0 13.9
600 mm O.C.
G' 19.9 18.2 20.5 18.6 20.7 18.7 20.7 18.7 20.5 18.5 20.4 18.4 20.2 18.3
SLSD 30.5 23.3 27.3 21.2 25.0 19.7 23.2 18.5 21.8 17.7 20.8 17.0 19.9 16.5
450 mm O.C.
G' 20.5 19.0 21.3 19.7 21.7 20.0 21.9 20.2 21.9 20.2 21.9 20.2 21.8 20.2
18
SLSD 34.2 27.3 31.3 25.4 29.2 24.1 27.7 23.1 26.4 22.4 25.4 21.8 24.6 21.3
300 mm O.C.
G' 21.4 20.3 22.6 21.3 23.3 22.1 23.8 22.5 24.2 22.9 24.4 23.2 24.6 23.3
SLSD 42.7 36.3 40.8 35.1 39.4 34.3 38.3 33.6 37.4 33.1 36.7 32.8 32.1 32.1
150 mm O.C.
G' 23.2 22.6 25.1 24.5 26.5 25.8 27.6 26.9 28.4 27.8 29.1 28.5 29.7 29.1
SLSD 52.1* 45.4 51.2* 44.9 50.6* 44.6 50.1* 44.3 49.8 44.1 39.6 39.6 32.1 32.1
75 mm O.C.
G' 25.0 24.7 27.5 27.3 29.5 29.2 31.1 30.8 32.4 32.1 33.5 33.2 34.4 34.2
SLSD 29.3 20.8 25.3 18.2 22.5 16.4 20.3 15.1 18.5 14.0 17.1 13.1 15.9 12.4
900 mm O.C.
G' 26.1 22.9 25.7 22.4 25.1 21.7 24.3 21.0 23.6 20.4 22.9 19.8 22.3 19.3
SLSD 31.7 23.5 27.9 21.0 25.2 19.3 23.2 18.0 21.7 17.1 20.4 16.3 19.3 15.7
600 mm O.C.
G' 27.1 24.4 27.1 24.2 26.8 23.9 26.3 23.5 25.9 23.1 25.4 22.7 24.9 22.4
SLSD 33.9 26.0 30.4 23.7 27.9 22.1 26.0 20.9 24.5 19.9 23.3 19.2 22.3 18.6
450 mm O.C.
G' 28.1 25.6 28.4 25.8 28.3 25.8 28.1 25.6 27.8 25.4 27.5 25.2 27.2 25.0
16
SLSD 38.1 30.5 35.0 28.5 32.7 27.1 31.0 26.0 29.7 25.2 28.6 24.6 27.7 24.0
300 mm O.C.
G' 29.6 27.7 30.4 28.5 30.9 28.9 31.0 29.1 31.1 29.2 31.1 29.3 31.1 29.3
SLSD 47.6 40.6 45.5 39.3 44.0 38.4 42.9 37.8 42.0 37.2 41.3 36.8 40.1 36.5
150 mm O.C.
G' 32.8 31.7 34.6 33.5 35.9 34.8 36.9 35.8 37.6 36.5 38.1 37.1 38.5 37.6
SLSD 57.8 50.4 56.9 49.9 56.3 49.6 55.8 49.3 55.4 49.1 49.5 49.0 40.1 40.1
75 mm O.C.
G' 36.0 35.6 38.8 38.4 40.9 40.5 42.6 42.1 43.9 43.5 45.0 44.6 45.9 45.5
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 5 mm tf 10 mm. For attachment to base steel thickness with
range 3 mm tf < 5 mm, diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
*For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19) of this document

30 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6'' 152 mm
36'' 914 mm
1-1/2'' 38 mm 914 mm 38 mm

Steel Deck Fastening Systems

X-HSN 24 for Fastening Deck to Bar Joist 1.2


c
36/4 914/5 (36/5)
914/5 914/4 (36/4)
914/4

6'' 152 mm 152 mm


36'' 914 mm
1-1/2'' 38 mm 914 mm 38 mm
Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
X-HSN 24 fasteners with 914/5 (36/5) or 914/4 (36/4) end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti 36/5
SLC6,7,8 Fasteners per sheet to support
914/7 914/5
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SLSD 10.1 8.2 8.9 7.3 8.0 6.7 7.3 6.2 6.8 5.8 6.3 5.5 6.0 5.2
900
6''mm
152O.C.
mm G' 2.3 1.7 2.7 2.0 3.1 2.3 3.5152 mm 2.6 3.8 2.9 4.1 3.1 4.3 3.3
36'' 914 mm 1-1/2'' 38 mm 914 mm 38 mm
SLSD 11.2 9.2 10.0 8.4 9.2 7.8 8.6 7.4 8.1 7.0 7.7 6.8 7.4 6.5
600 mm O.C..
G' 2.3 1.7 2.8 2.0 3.2 2.4 3.6 2.7 3.9 3.0 4.3 3.3 4.6 3.5
SLSD 12.1 10.0 11.1 9.3 10.3 8.8 9.7 8.4 9.3 8.1 9.0 7.9 8.7 7.7
450 mm O.C.
G' 2.3 1.7 2.8 2.1 3.3 2.4 3.7 2.7 4.0 3.1 4.4 3.3 4.7 3.6
22
SLSD 13.8 11.4 12.9 10.9 12.3 10.5 11.8 10.2 11.4 9.9 11.1 9.8 10.9 9.6
300 mm O.C.
G' 2.4 1.7 2.9 2.1 3.3 2.5 3.8 2.8 4.2 3.1 4.6 3.5 4.9 3.8
SLSD 17.2 13.9 16.7 13.7 16.3 13.5 16.1 13.4 15.9 13.3 15.7 13.2 15.6 13.1
36/7
150 mm O.C. 914/9 914/7
G' 2.4 1.7 2.9 2.1 3.4 2.5 3.9 2.9 4.4 3.3 4.8 3.6 5.2 3.9
SLSD 17.2 13.9 16.7 13.7 16.3 13.5 16.1 13.4 15.9 13.3 15.7 13.2 15.6 13.1
756''
mm O.C.
152 mm G' 2.4 1.8 3.0 2.2 3.5 2.6 4.0152 mm 3.0 4.5 3.3 5.0 3.7 5.4 4.0
36'' 914 mm 1-1/2'' 38 mm 914 mm 38 mm
SLSD 13.5 11.0 11.9 9.9 10.8 9.1 10.0 8.5 9.3 8.0 8.8 7.6 8.3 7.3
900 mm O.C.
G' 3.5 2.6 4.1 3.1 4.7 3.5 5.1 3.9 5.5 4.3 5.8 4.6 6.1 4.8
SLSD 15.0 12.4 13.6 11.4 12.5 10.7 11.8 10.1 11.2 9.7 10.7 9.4 10.3 9.1
600 mm O.C.
G' 3.6 2.6 4.2 3.2 4.8 3.6 5.3 4.1 5.8 4.5 6.2 4.8 6.6 5.1
SLSD 16.4 13.6 15.1 12.7 14.1 12.1 13.4 11.6 12.9 11.2 12.4 10.9 12.1 10.7
450 mm O.C.
G' 3.6 2.7 4.3 3.2 4.9 3.7 5.5 4.2 6.0 4.6 6.4 5.0 6.9 5.4
20
SLSD 18.7 15.4 17.6 14.8 16.8 14.3 16.3 14.0 15.8 13.7 15.5 13.5 15.2 13.3
36/9
300 mm O.C. 914/11 914/9
G' 3.7 2.7 4.4 3.3 5.1 3.8 5.7 4.3 6.3 4.8 6.8 5.2 7.3 5.6
SLSD 23.1 18.6 22.6 18.4 22.2 18.2 21.9 18.1 21.7 17.9 21.5 17.8 21.3 17.8
150
6''mm
152O.C.
mm G' 3.8 2.8 4.6 3.4 5.3 3.9 6.0152 mm 4.5 6.7 5.0 7.3 5.5 7.9 6.0
36'' 714 mm 1-1/2'' 38 mm 914 mm 38 mm
SLSD 23.1 18.6 22.6 18.4 22.2 18.2 21.9 18.1 21.7 17.9 21.5 17.8 21.3 17.8
75 mm O.C.
G' 3.8 2.8 4.7 3.4 5.5 4.0 6.2 4.6 6.9 5.2 7.6 5.7 8.3 6.3
SLSD 16.8 13.7 14.9 12.4 13.5 11.4 12.5 10.7 11.7 10.1 11.1 9.6 10.6 9.3
900 mm O.C.
G' 6.4 4.8 7.3 5.5 8.0 6.2 8.5 6.7 8.9 7.1 9.3 7.5 9.5 7.8
SLSD 18.7 15.5 17.0 14.3 15.7 13.4 14.8 12.8 14.1 12.3 13.5 11.9 13.0 11.6
600 mm O.C.
G' 6.5 4.9 7.5 5.7 8.3 6.5 9.0 7.1 9.6 7.6 10.1 8.1 10.5 8.5
SLSD 20.4 16.9 18.9 15.9 17.8 15.2 16.9 14.6 16.3 14.2 15.7 13.9 15.3 13.6
36/11
450 mm O.C. 914/11
G' 6.6 5.0 7.7 5.9 8.6 6.7 9.4 7.4 10.1 8.0 10.7 8.6 11.2 9.1
18
SLSD 23.3 19.3 22.1 18.5 21.2 18.0 20.5 17.6 20.0 17.3 19.6 17.0 19.2 16.8
300
6''mm O.C. 152 mm
G' 6.8 5.1 8.0 6.1 9.1 7.0 10.0 7.8 10.8 8.5 11.5 9.2 12.2 9.8
36'' 1-1/2'' 714 mm 38 mm
SLSD 28.8 23.1 28.2 22.8 27.7 22.6 27.4 22.5 27.2 22.3 27.0 22.2 26.8 22.2
150 mm O.C.
G' 7.1 5.3 8.5 6.4 9.7 7.4 10.8 8.3 11.9 9.2 12.8 10.0 13.7 10.8
SLSD 28.8 23.1 28.2 22.8 27.7 22.6 27.4 22.5 27.2 22.3 27.0 22.2 26.8 22.2
75 mm O.C.
G' 7.3 5.4 8.8 6.6 10.2 7.7 11.4 8.7 12.6 9.7 13.7 10.6 14.8 11.5
SLSD 18.6 15.3 16.6 13.8 15.1 12.7 14.0 11.9 13.1 11.3 12.4 10.8 11.9 10.4
900 mm O.C.
G' 10.0 7.7 11.1 8.6 11.8 9.4 12.3 9.9 12.7 10.4 12.9 10.7 13.1 11.0
SLSD 20.8 17.2 19.0 16.0 17.6 15.0 16.6 14.3 15.8 13.8 15.2 13.4 14.7 13.0
600 mm O.C.
G' 10.4 7.9 11.6 9.1 12.6 10.0 13.3 10.7 13.9 11.4 14.3 11.9 14.7 12.3
SLSD 22.8 18.9 21.1 17.8 19.9 17.0 19.0 16.4 18.3 16.0 17.7 15.6 17.2 15.3
450 mm O.C.
G' 10.6 8.1 12.0 9.4 13.2 10.4 14.1 11.3 14.8 12.1 15.4 12.8 16.0 13.3
16
SLSD 26.0 21.5 24.7 20.7 23.7 20.1 23.0 19.7 22.4 19.4 22.0 19.1 21.6 18.9
300 mm O.C.
G' 11.0 8.4 12.7 9.8 14.0 11.1 15.2 12.2 16.2 13.1 17.0 14.0 17.8 14.8
SLSD 32.0 25.6 31.4 25.3 30.9 25.1 30.6 25.0 30.3 24.8 30.1 24.7 29.9 24.7
150 mm O.C.
G' 11.7 8.9 13.7 10.5 15.5 12.0 17.0 13.4 18.4 14.7 19.6 15.8 20.7 16.9
SLSD 32.0 25.6 31.4 25.3 30.9 25.1 30.6 25.0 30.3 24.8 30.1 24.7 29.9 24.7
75 mm O.C.
G' 12.2 9.2 14.5 11.0 16.5 12.7 18.4 14.3 20.1 15.8 21.6 17.1 23.0 18.4
1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 5 mm tf 10 mm. For attachment to base steel thickness with
range 3 mm tf < 5 mm, diaphragm shear values should be calculated in accordance with Section 1.1.8.
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60..

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 31
Steel Deck Fastening Systems

1.2 X-HSN 24 for Fastening Deck to Bar Joist


c
Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada)
Diaphragm Table 36-7 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
with X-HSN 24 Metric for 38 mm deep steel nestable deck fastened w/Hilti X-HSN 24 w/screwed sidelaps (Canada only)1,2,3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection #10 screw at 600 mm O.C. #10 screw at 450 mm O.C. #10 screw at 300 mm O.C. #10 screw at 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 6.5 7.9 10.2 12.8 6.5 7.9 10.2 12.8 8.3 10.1 13.3 16.7 11.6 14.0 18.4 23.1
1200
Flexibility Factor, F 120 88 60 45 120 88 60 45 110 79 52 38 101 71 45 32
Strength, SLSD 5.2 6.2 8.2 10.3 6.1 7.4 9.6 12.1 7.6 9.3 12.2 15.3 11.0 13.4 17.6 22.0
1500
Flexibility Factor, F 115 88 62 49 108 81 56 43 99 73 49 37 89 64 42 30
Strength, SLSD 5.1 6.1 8.1 10.1 5.8 7.1 9.3 11.6 7.2 8.7 11.4 14.3 10.7 12.9 17.0 21.3
1800
Flexibility Factor, F 106 81 59 46 99 76 54 42 91 68 47 36 81 59 39 29
Strength, SLSD 4.2 5.2 6.9 8.7 4.9 6.0 8.0 10.0 6.8 8.2 10.8 13.6 9.6 12.6 16.6 20.7
2100
Flexibility Factor, F 106 83 62 50 99 77 56 45 86 66 46 36 75 56 38 28
Strength, SLSD 4.2 5.2 6.9 8.7 4.8 5.9 7.9 9.9 6.6 7.9 10.5 13.0 7.4 9.8 15.0 20.3
2400
Flexibility Factor, F 99 79 59 48 94 73 54 44 83 64 46 36 71 53 37 28
Strength, SLSD 3.8 4.6 6.1 7.6 4.8 5.9 7.8 9.8 5.9 7.6 10.1 12.7 5.9 7.8 11.9 16.6
2700
Flexibility Factor, F 101 82 62 51 90 71 53 43 80 62 45 36 68 51 36 27
Strength, SLSD 3.9 4.7 6.2 7.8 4.3 5.3 6.9 8.7 4.7 6.2 9.6 12.3 4.7 6.2 9.6 13.5
3000
Flexibility Factor, F 96 78 60 49 91 73 55 45 77 61 45 36 65 50 35 27

Diaphragm Table 36-4 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
with X-HSN 24 Metric for 38 mm deep steel nestable deck fastened w/Hilti X-HSN 24 w/screwed sidelaps (Canada only)1,2,3
No. of transverse nails per 900 mm wide deck units=4 (every other flute)
Sidelap Connection #10 screw at 600 mm O.C. #10 screw at 450 mm O.C. #10 screw at 300 mm O.C. #10 screw at 150 mm O.C.
Span (mm)
deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 4.7 5.6 7.4 9.3 4.7 5.6 7.4 9.3 6.2 7.4 9.8 12.2 8.1 9.8 12.8 16.0
1200
Flexibility Factor, F 595 384 210 132 595 384 210 132 578 369 197 120 567 359 188 113
Strength, SLSD 3.9 4.7 6.1 7.6 4.6 5.5 7.3 9.2 5.9 7.1 9.3 11.6 7.9 9.5 12.6 15.7
1500
Flexibility Factor, F 500 328 186 122 487 317 176 113 474 305 166 103 462 294 156 95
Strength, SLSD 4.0 4.7 6.2 7.8 4.6 5.5 7.2 9.2 5.6 6.8 8.9 11.2 7.8 9.4 12.3 15.5
1800
Flexibility Factor, F 425 281 161 106 415 272 154 100 405 262 145 92 392 251 135 83
Strength, SLSD 3.4 4.1 5.4 6.8 4.0 4.8 6.3 7.9 5.4 6.6 8.6 10.8 7.6 9.3 12.2 15.3
2100
Flexibility Factor, F 383 257 152 103 372 247 143 96 355 232 130 84 342 220 120 75
Strength, SLSD 3.5 4.2 5.6 7.1 4.0 4.8 6.3 8.0 5.3 6.3 8.5 10.6 7.6 9.2 12.1 15.2
2400
Flexibility Factor, F 340 230 137 94 332 222 130 88 318 209 119 78 304 197 108 68
Strength, SLSD 3.1 3.8 4.9 6.2 4.0 4.9 6.5 8.1 5.2 6.2 8.2 10.3 7.5 9.2 12.0 15.0
2700
Flexibility Factor, F 318 218 133 93 301 203 120 82 289 192 110 73 275 179 99 63
Strength, SLSD 3.2 3.9 5.2 6.6 3.6 4.5 5.9 7.4 5.1 6.2 8.1 10.2 7.5 9.0 12.0 14.9
3000
Flexibility Factor, F 290 365 123 86 283 193 117 81 266 177 103 69 252 165 92 59

Diaphragm Table 36-7 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
with X-HSN 24 Metric for 38 mm deep steel deck fastened w/Hilti X-HSN 24 w/button punch sidelaps (Canada only)1,2,3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 5.8 7.1 9.5 12.1 5.8 7.1 9.5 12.1 6.5 8.1 11.2 14.8 7.8 10.0 14.3 19.6
1200
Flexibility Factor, F 129 96 67 51 129 96 67 51 126 94 65 50 122 90 62 47
Strength, SLSD 4.6 5.6 7.5 9.8 4.8 6.0 8.3 10.9 5.5 6.9 9.9 13.2 6.9 8.9 13.2 18.2
1500
Flexibility Factor, F 126 97 71 56 125 96 69 55 122 94 67 53 116 88 63 49
Strength, SLSD 4.0 4.9 6.9 9.2 4.2 5.4 7.5 10.1 4.8 6.1 8.8 12.1 6.2 8.2 12.2 17.3
1800
Flexibility Factor, F 126 100 75 61 124 98 73 59 121 95 71 57 114 89 65 52
Strength, SLSD 3.4 4.2 5.9 7.8 3.6 4.6 6.5 8.7 4.2 5.5 8.1 11.3 5.8 7.8 11.6 16.6
2100
Flexibility Factor, F 130 105 81 66 128 103 79 65 122 98 75 61 113 90 67 55
Strength, SLSD 3.2 4.0 5.6 7.5 3.3 4.2 6.1 8.3 3.9 5.1 7.5 10.7 5.4 7.3 11.2 16.0
2400
Flexibility Factor, F 133 109 85 71 130 107 83 69 125 102 79 66 113 91 70 57
Strength, SLSD 2.7 3.5 4.9 6.6 3.1 4.0 5.8 8.0 3.6 4.7 7.2 10.1 5.2 6.9 10.8 15.6
2700
Flexibility Factor, F 139 115 92 77 134 111 88 74 128 106 83 70 114 93 72 60
Strength, SLSD 2.6 3.3 4.8 6.6 2.7 3.5 5.2 7.2 3.4 4.5 6.8 9.8 4.9 6.7 10.5 15.3
3000
Flexibility Factor, F 143 120 96 81 140 118 94 80 131 110 87 73 115 95 75 62
1 The ratio of span of deck unit to average length of sheet is taken to be 1/3.
2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi.
3 Values shown calculated in accordance with SDI equations using a factor of 0.5 for LSD for all load conditions.

32 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

X-HSN 24 for Fastening Deck to Bar Joist 1.2


c
Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada)
Diaphragm Table 36-4 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor,
with X-HSN 24 Metric F, (mm x 10-6/N) for 38 mm deep steel deck fastened w/Hilti X-HSN 24 w/button punch sidelaps (Canada only)1,2,3
No. of transverse nails per 900 mm wide deck units=4 (every other flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 4.1 4.3 5.7 7.4 3.5 4.3 5.7 7.4 4.0 5.0 7.0 9.3 4.8 6.2 8.9 12.0
1200
Flexibility Factor, F 612 399 224 144 612 399 224 144 607 395 220 141 599 388 214 135
Strength, SLSD 3.3 4.0 5.5 7.2 3.5 4.5 6.2 8.1 4.1 5.2 7.4 10.0 5.3 6.8 9.9 13.6
1500
Flexibility Factor, F 521 348 203 137 518 345 201 134 513 340 196 130 502 330 188 123
Strength, SLSD 2.9 3.6 5.2 6.9 3.2 4.1 5.9 7.9 3.6 4.7 6.9 9.4 4.9 6.5 9.5 13.2
1800
Flexibility Factor, F 462 315 190 132 459 311 188 130 452 306 183 125 438 293 172 116
Strength, SLSD 2.5 3.2 4.5 6.0 2.7 3.8 4.9 6.8 3.3 4.5 6.5 8.9 4.7 6.1 9.2 12.9
2100
Flexibility Factor, F 426 297 186 134 422 293 183 131 412 283 175 124 394 268 161 111
Strength, SLSD 2.4 2.9 4.3 6.0 2.5 3.5 4.8 6.7 3.1 4.1 6.2 8.6 4.5 5.9 8.9 12.7
2400
Flexibility Factor, F 398 282 182 134 394 278 179 131 383 268 170 123 362 249 154 109
Strength, SLSD 2.0 2.6 3.8 5.3 2.4 3.4 4.7 6.6 2.9 3.9 6.0 8.3 4.2 5.8 8.8 12.5
2700
Flexibility Factor, F 382 276 184 139 373 268 177 132 361 257 168 124 337 236 149 107
Strength, SLSD 2.0 2.6 3.8 5.3 2.1 3.2 4.2 6.0 2.7 3.6 5.8 8.1 4.1 5.6 8.7 12.3
3000
Flexibility Factor, F 367 393 183 140 362 265 180 137 346 250 166 125 318 225 145 106

Diaphragm Table 24-5 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
with X-HSN 24 Metric for 75 mm deep steel deck fastened with Hilti X-HSN 24 w/button punch sidelaps (Canada only)1, 2, 3
No. of transverse nails per 600 mm wide deck units=5 (every flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 2.0 2.6 3.7 5.2 2.1 2.8 4.2 5.8 2.6 3.5 5.4 7.8 3.9 5.4 8.8 12.9
2400
Flexibility Factor, F 281 227 173 143 275 222 169 139 262 209 158 130 235 185 137 111
Strength, SLSD 1.7 2.2 3.3 4.5 2.0 2.6 4.0 5.7 2.4 3.3 5.1 7.5 3.7 5.2 8.5 12.6
2700
Flexibility Factor, F 290 238 185 154 279 227 176 146 264 214 165 136 233 186 140 115
Strength, SLSD 1.6 2.1 3.2 4.5 1.7 2.3 3.5 5.1 2.3 3.1 4.9 7.2 3.6 5.0 8.2 12.4
1800
Flexibility Factor, F 295 244 192 161 289 238 187 157 268 220 171 143 233 188 143 118
Strength, SLSD 1.4 1.9 2.9 4.1 1.7 2.2 3.5 5.0 2.1 2.9 4.7 7.0 3.4 4.8 8.0 12.2
3300
Flexibility Factor, F 307 257 205 173 293 245 194 164 272 225 177 149 233 189 146 121
Strength, SLSD 1.4 1.9 2.9 4.1 1.6 2.2 3.4 5.0 2.0 2.8 4.5 6.8 3.3 4.7 7.9 12
3600
Flexibility Factor, F 312 263 211 180 299 251 201 170 277 231 183 155 233 191 149 124
Strength, SLSD 1.2 1.7 2.6 3.8 1.4 2.0 3.1 4.6 1.9 2.7 4.4 6.6 3.2 4.6 7.8 11.9
3900
Flexibility Factor, F 325 276 224 191 311 263 212 181 282 237 189 160 234 193 152 127
Strength, SLSD 1.2 1.6 2.6 3.8 1.4 1.9 3.1 4.6 1.9 2.6 4.3 6.5 3.2 4.5 7.6 11.8
4200
Flexibility Factor, F 331 282 230 197 316 269 218 186 287 242 195 166 235 195 154 129
1 The ratio of span of deck unit to average length of sheet is taken to be 1/3.
2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi.
3 Values shown calculated in accordance with SDI equations using a factor of 0.5 for LSD for all load conditions.

Note: Reference pages 30-31 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC).

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 33
Steel Deck Fastening Systems

1.2 X-HSN 24 for Fastening Deck to Bar Joist

1.2.4 Ordering Information

DX 860-HSN Decking System


Tools
Description Notes Qty
Use-on-Demand service provides
DX 860-HSN Stand-Up Decking Tool 1 pcs
daily rental

Accessories
Description Notes Qty
Replacement piston and brake
HSN Piston and Brake Spares Pack 1 pcs
for DX 860-HSN

Fasteners (Combos with 40-strip Cartridges)


Description Notes Qty
X-HSN 24 bulk fastener/cartridge combo 1/8" (3 mm) tf 3/8" (10 mm) 2,000 pcs
X-HSN 24 pallet fastener/cartridge combo 1/8" (3 mm) tf 3/8" (10 mm) 32,000 pcs

DX 460-SM Decking System


Tools
Description Notes Qty
DX 460-SM Hand Held Decking Tool 1 pcs

Accessories
Description Notes Qty
Magazine X-SM Replacement magazine for DX 460-SM 1 pcs
Piston X-AP PSM Replacement piston for DX 460-SM 1 pcs
Buffer (reinforced) X-460-B Replacement buffer for DX-460-SM 1 pcs

Fasteners (Combos with 10-strip cartridges for DX 460-SM)


Description Notes Qty
X-HSN 24 bulk fastener/cartridge combo 3/16" (5 mm) tf 3/8" (10 mm) 1,000 pcs
X-HSN 24 pallet fastener/cartridge combo 3/16" (5 mm) tf 3/8" (10 mm) 32,000 pcs

34 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

X-ENP-19 for Fastening Deck to Structural Steel 1.3

1.3.1 Product Description 1.3.1 Product Description

The Hilti structural steel deck fastening fasteners are available in collated strips 1.3.2 Material Specifications

system consists of powder-actuated of 10. Four of these strips are loaded into 1.3.3 Technical Data
tools which are primarily used with one the DX 860-ENP-L tool along with the 1.3.4 Ordering Information
fastener: the X-ENP-19 L15, which is cartridge strip, and enable the operator
available either collated or non-collated. to fasten at a rate of up to 1,000 quality
fastenings per hour.
For most structural steel decking jobs,
the tool of choice is the DX 860-ENP-L Other tools include the hand held X-ENP-19 L15 MX and MXR
tool. This self-contained stand up decking DX 76-MX, a semi-automatic magazine
tool is powered by 0.27 caliber long tool. Other configurations of the DX 76
cartridges, which are loaded into the tool include a single fastener guide variation
in strips of 40. The cartridges drive the of the tool for miscellaneous use.
X-ENP-19 L15 MXR fastener (collated
Hilti X-ENP-19 steel deck fasteners
version) into almost any type
comply with ANSI/SDI RD1.0, C1.0
of steel deck and base steel thicknesses
and NC1.0 standards. X-ENP-19 L15
greater than or equal to 1/4". These

Approvals/Listings
1.3.2 Material Specifications ICC-ES (International Code Council)
ESR-2776, ESR-2197, ESR-1116,
Fastener Fastener Nominal fastener
Fastener ESR-1169, ESR-1414
material plating hardness
COLA (City of Los Angeles)
X-ENP-19 L15 Carbon Steel 5 m Zinc1 58 HRC RR 25877, RR 25296
1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide FM (Factory Mutual)
Volume 1: Direct Fastening for more information. For attaching Class 1 Steel Roof Decks
with 1-60 and 1-90 wind uplift ratings.
Listed for higher wind uplift ratings with
1.3.3 Technical Data FM Approved Lightweight Insulating
Allowable pullout loads for attachments to steel base material lb (kN)1, 2, 3 Concrete Roof Deck Assemblies.
Refer to FM RoofNav for specific
Base material thickness (in.) assembly listings.
Fastener UL (Underwriters Laboratories)
1/4 3/8 1/2 4 5/8 4
X-ENP-19 L15 905 (4.03) 1125 (5.00) 1010 (4.49) 965 (4.29) Fasteners for attaching steel roof deck
(uplift and fire classification)
1 These values represent testing performed in ASTM A36 plate steel.
ABS (American Bureau of Shipping)
2 The values must be compared with allowable tensile pullover values.
3 Allowable values based on safety factor of 5.0.
4 Allowable values are based on minimum 1/2" penetration depth through or into base steel. For 3/8"
penetration depth into 1/2" and thicker steels, reduce the allowable load capacity to 635 lb (2.79 kN).

Allowable pullover and shear bearing loads for attaching steel deck 1,2,3

Steel deck gauge (in.)


16 (0.0598) 18 (0.0474) 20 (0.0358) 22 (0.0295) 24 (0.0239) 26 (0.0179)
Fastener
Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear
lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
940 1050 875 840 755 640 665 535 400 440 185 335
X-ENP-19 L15
(4.14) (4.62) (3.85) (3.70) (3.32) (2.82) (2.93) (2.35) (1.78) (1.94) (0.81) (1.47)
1 Minimum base steel thickness must be greater than or equal to 1/4" (6 mm).
2 Allowable values are based on a safety factor of 3.0.
3 Loads based on ASTM A1008, or minimum ASTM A653 SQ33 steel deck.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 35
6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

1.3 X-ENP-19 for Fastening Deck to Structural Steel

36/9 36/7 914/9

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Allowable Stress Design (ASD)-Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard
1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti X-ENP-19 L15 fasteners
with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/11 36/9 914/11
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SASD 804 561 688 485 595 426 525 383 473 352 436 329 408 311
36" O.C. 6'' 6'' 152 mm
G' 55.7 52.8 61.5 57.5 65.6 60.5 68.3 62.4 69.9 63.7 71.4 64.1 71.9 64.5
36'' 1-1/2'' 36'' 714 mm1-1/2'' 38 mm
SASD 861 623 750 550 670 499 601 459 549 427 512 404 483 386
24" O.C.
G' 56.2 53.7 62.5 59.0 67.0 62.7 70.2 65.3 72.5 67.1 74.1 68.5 75.2 69.4
SASD 915 683 808 613 732 564 675 528 624 500 587 478 558 461
18" O.C.
G' 56.8 54.3 63.3 60.2 68.0 64.5 71.9 67.6 74.6 69.9 76.9 71.9 78.1 73.5
22
SASD 1016 793 919 730 849 685 796 652 755 627 723 607 697 591
12" O.C.
G' 57.5 55.7 64.6 62.3 70.2 67.4 74.5 71.4 78.1 74.6 80.6 77.5 83.3 79.4
SASD 1263 1058 1192 1014 1140 982 1101 958 1070
6" O.C. 36/11 940 938 926 760 760
G' 59.2 58.1 67.1 66.1 74.1 72.6 80.0 78.1 84.7 82.6 88.5 87.0 91.7 90.1
SASD 1568 1362 1532 1341 1505 1327 1485 1316 1188 1188 938 938 760 760
3" O.C. 6''
G' 61.0 60.2 69.9 69.4 78.1 77.5 84.7 84.0 90.1 89.3 95.2 94.3 100.0 99.0
36'' 1-1/2''
SASD 1038 731 892 636 783 566 695 513 629 472 578 441 541 418
36" O.C.
G' 78.5 73.3 84.6 77.7 88.2 80.0 90.1 81.0 91.0 81.2 90.9 81.3 90.9 80.6
SASD 1117 819 979 728 880 664 803 617 737 580 686 549 649 526
24" O.C.
G' 79.5 74.9 86.2 80.2 90.5 83.5 93.2 85.4 94.8 86.6 96.2 87.0 96.2 87.7
SASD 1193 902 1061 815 967 755 896 710 841 676 793 649 757 627
18" O.C.
G' 80.0 76.3 87.7 82.6 92.6 86.2 96.2 89.3 98.0 90.9 100.0 92.6 101.0 93.5
20
SASD 1333 1055 1214 978 1129 923 1064 883 1014 852 975 828 942 808
12" O.C.
G' 81.8 78.5 89.9 85.9 95.8 91.2 100.2 95.1 103.5 98.1 106.4 100.0 107.5 102.0
SASD 1666 1409 1583 1358 1523 1321 1477 1294 1441 1273 1222 1222 990 990
6" O.C.
G' 84.8 83.0 94.7 92.5 102.5 100.0 108.7 106.1 113.8 111.0 117.6 114.9 122.0 119.0
SASD 2050 1784 2012 1763 1983 1748 1962 1737 1547 1547 1222 1222 990 990
3" O.C.
G' 88.5 87.0 100.0 99.0 108.7 107.5 117.6 116.3 123.5 122.0 129.9 128.2 135.1 133.3
SASD 1254 886 1079 771 956 692 851 628 772 580 710 542 661 512
36" O.C.
G' 123.5 113.6 128.4 115.0 129.6 114.7 129.1 113.2 127.5 111.2 125.5 109.1 123.5 106.4
SASD 1352 994 1186 885 1068 809 979 753 906 710 844 676 795 646
24" O.C.
G' 126.6 116.3 131.6 120.6 133.9 120.9 134.5 120.8 134.1 120.0 133.0 118.9 131.6 117.6
SASD 1446 1097 1288 993 1175 921 1090 868 1025 827 973 795 928 769
18" O.C.
G' 128.2 119.0 135.1 123.5 137.0 126.6 138.9 128.2 140.8 128.2 138.9 126.6 138.9 126.6
18
SASD 1617 1285 1476 1193 1374 1128 1298 1080 1238 1044 1191 1015 1152 991
12" O.C.
G' 131.6 123.5 139.3 131.0 144.3 135.2 147.4 138.0 149.4 139.8 150.6 141.0 151.5 140.8
SASD 2023 1715 1926 1655 1855 1612 1801 1581 1759 1556 1725 1537 1420 1420
6" O.C.
G' 138.9 133.3 149.5 144.7 157.7 152.6 163.9 158.7 168.7 163.4 172.4 167.2 175.4 169.5
SASD 2484 2163 2440 2138 2407 2121 2383 2108 2219 2099 1753 1753 1420 1420
3" O.C.
G' 147.1 144.9 161.3 158.7 172.4 169.5 181.8 178.6 188.7 185.2 196.1 192.3 200.0 196.1
SASD 1277 908 1102 793 978 713 881 654 801 605 739 567 690 537
36" O.C.
G' 172.4 153.8 172.4 151.5 170.3 147.8 166.5 143.5 162.2 139.1 157.8 135.0 153.5 131.1
SASD 1382 1023 1216 914 1098 838 1010 782 942 740 883 706 833 679
24" O.C.
G' 175.4 158.7 178.6 158.7 177.0 157.2 174.7 154.4 171.7 151.4 168.4 148.5 165.2 145.7
SASD 1481 1132 1324 1029 1212 957 1128 904 1063 864 1011 832 969 806
18" O.C.
G' 178.6 163.9 181.8 166.7 181.8 166.7 181.8 163.9 178.6 161.3 178.6 161.3 175.4 158.7
16
SASD 1662 1330 1523 1239 1423 1176 1347 1129 1289 1093 1242 1064 1204 1041
12" O.C.
G' 185.2 172.4 192.3 175.4 193.4 179.1 194.4 179.9 194.4 180.1 193.9 179.8 193.0 179.4
SASD 2082 1773 1989 1716 1922 1676 1870 1646 1830 1622 1797 1604 1771 1589
6" O.C.
G' 196.1 188.7 208.3 200.0 215.3 206.9 220.4 212.0 224.1 215.8 226.8 218.8 228.9 221.1
SASD 2542 2214 2501 2192 2472 2177 2450 2166 2432 2157 2191 2150 1775 1775
3" O.C.
G' 212.8 208.3 227.3 222.2 238.1 232.6 250.0 243.9 256.4 250.0 263.2 256.4 263.2 263.2
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 1/4".
2 Tabulated ASD diaphragm shear loads are calculated with a safety factor () of 2.35 for wind loads. To calculate ASD values for load combinations involving
earthquake, multiply values in table by 2.35 and divide by a safety factor () of 2.50. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

36 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

X-ENP-19 for Fastening Deck to Structural Steel 1.3

36/5 36/4 914/5

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Allowable Stress Design (ASD)-Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard
1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti X-ENP-19 L15 fasteners
with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/5
36/7 914/7
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SASD 504 410 442 365 398 333 365 309 336 288 315 272 298 260
36" O.C. 6'' 6'' 152 mm
G' 13.6 9.9 16.3 11.9 18.8 13.8 21.0 15.6 23.0
36'' 1-1/2'' 36''17.2 24.8 18.7 1-1/2''
914 mm
26.3 20.1
38 mm
SASD 557 458 499 418 458 389 428 367 404 351 385 337 370 326
24" O.C.
G' 13.6 9.9 16.4 12.0 19.0 14.0 21.4 15.9 23.5 17.6 25.5 19.3 27.3 20.8
SASD 605 501 552 465 514 440 485 420 463 405 446 393 431 383
18" O.C.
G' 13.7 10.0 16.6 12.1 19.2 14.2 21.7 16.1 23.9 17.9 26.0 19.6 28.0 21.3
22
SASD 688 572 644 544 613 524 589 509 570 497 555 487 542 479
12" O.C.
G' 13.8 10.0 16.8 12.2 19.5 14.4 22.1 16.4 24.6 18.3 26.8 20.2 29.0 21.9
SASD
6" O.C. 36/9 862 700 837 688 819 679 806 672 79536/7 666 787
914/9662 760 658
G' 14.0 10.1 17.1 12.4 20.0 14.7 22.8 16.8 25.4 18.9 28.0 20.9 30.4 22.8
SASD 862 700 837 688 819 679 806 672 795 666 787 662 760 658
3" O.C. 6'' 6'' 152 mm
G' 14.1 10.2 17.3 12.6 20.4 14.9 23.3 17.1 26.1 19.3 28.8 21.4 31.4 23.5
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SASD 656 536 579 481 525 441 484 411 452 388 423 370 402 354
36" O.C.
G' 21.1 15.4 24.9 18.4 28.3 21.2 31.3 23.6 33.7 25.7 35.8 27.7 37.7 29.4
SASD 729 602 659 554 608 519 571 492 541 472 518 455 499 442
24" O.C.
G' 21.2 15.5 25.3 18.7 28.8 21.6 32.1 24.2 34.8 26.6 37.3 28.7 39.5 30.8
SASD 795 660 731 618 685 587 651 564 624 546 602 531 585 519
18" O.C.
G' 21.4 15.6 25.5 18.9 29.2 21.9 32.7 24.6 35.7 27.2 38.5 29.5 41.0 31.7
20
SASD
36/11 908 753 856 721 819 698 790 681 76836/9 667 750
914/11656 736 647
12" O.C.
G' 21.6 15.8 25.9 19.1 29.9 22.3 33.6 25.2 36.9 28.0 40.0 30.6 42.9 33.0
SASD 1130 913 1103 899 1084 890 1069 883 1058 877 1048 872 990 868
6" O.C. 6'' 6'' 152 mm
G' 22.0 16.0 26.6 19.6 30.9 22.9 35.0 26.2 38.8 29.2 42.4 32.2 1-1/2''
45.9 35.0
36'' 1-1/2'' 36'' 714 mm 38 mm
SASD 1130 913 1103 899 1084 890 1069 883 1058 877 1048 872 990 868
3" O.C.
G' 22.3 16.2 27.1 19.9 31.7 23.4 36.1 26.8 40.2 30.1 44.1 33.2 47.8 36.2
SASD 795 650 703 584 637 536 588 501 551 474 521 452 493 434
36" O.C.
G' 38.8 28.8 44.6 33.7 49.3 37.8 53.2 41.2 56.2 44.0 58.5 46.4 60.2 48.3
SASD 884 731 801 673 741 632 695 600 661 576 633 556 610 540
24" O.C.
G' 39.2 29.2 45.5 34.4 50.8 38.9 55.2 42.8 58.8 46.1 61.7 49.1 64.5 51.5
SASD 965 801 890 751 835 715 794 688 762
36/11 666 736 649 715 635
18" O.C.
G' 39.7 29.5 46.3 35.0 51.8 39.7 56.8 44.1 61.0 47.8 64.5 51.0 67.6 54.1
18
SASD 1103 914 1042 877 998 850 964 830 938 814 917 801 900 790
12" O.C. 6''
G' 40.3 30.0 47.4 35.8 53.8 41.0 59.2 45.7 64.1 50.0 68.5 54.0 71.9 57.5
36'' 1-1/2''
SASD 1370 1105 1339 1089 1317 1079 1300 1070 1287 1064 1276 1059 1267 1054
6" O.C.
G' 41.5 30.8 49.3 37.1 56.5 42.9 63.3 48.4 69.0 53.5 74.6 58.3 79.4 62.9
SASD 1370 1105 1339 1089 1317 1079 1300 1070 1287 1064 1276 1059 1267 1054
3" O.C.
G' 42.4 31.3 51.0 38.2 58.8 44.4 66.2 50.5 73.0 56.2 79.4 61.3 85.5 66.7
SASD 813 666 722 601 657 554 608 519 570 492 540 470 516 452
36" O.C.
G' 62.1 46.9 69.4 53.5 74.6 58.6 78.7 62.4 81.3 65.4 83.3 67.7 84.0 69.5
SASD 908 751 825 695 766 654 721 624 687 599 659 580 637 565
24" O.C.
G' 63.3 47.8 71.4 55.2 77.5 61.0 82.6 65.7 86.2 69.6 89.3 72.9 91.7 75.6
SASD 993 825 919 776 865 741 825 715 794 694 768 677 748 663
18" O.C.
G' 64.1 48.8 73.0 56.5 80.0 62.9 86.2 68.5 90.1 73.0 94.3 76.9 97.1 80.0
16
SASD 1136 940 1077 905 1035 880 1002 860 977 845 957 833 940 823
12" O.C.
G' 65.8 49.8 75.8 58.1 84.0 65.7 90.9 72.1 97.1 77.8 102.0 82.8 106.4 87.2
SASD 1404 1128 1376 1114 1355 1105 1340 1097 1328 1091 1318 1087 1310 1083
6" O.C.
G' 68.5 51.8 80.0 61.3 90.1 70.2 99.0 78.2 107.5 85.5 114.9 92.1 120.5 98.2
SASD 1404 1128 1376 1114 1355 1105 1340 1097 1328 1091 1318 1087 1310 1083
3" O.C.
G' 70.9 53.2 84.0 64.1 96.2 74.1 106.4 82.6 116.3 91.7 125.0 99.0 133.3 106.4
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 1/4".
2 Tabulated ASD diaphragm shear loads are calculated with a safety factor () of 2.35 for wind loads. To calculate ASD values for load combinations involving
earthquake, multiply values in table by 2.35 and divide by a safety factor () of 2.50. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 37
6'' 152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

1.3 X-ENP-19 for Fastening Deck to Structural Steel

36/9 36/7 914/9

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Load Resistance Factor Design (LRFD) Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
X-ENP-19 L15 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/11 36/9 914/11
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SLRFD 1322 922 1131 796 977 699 863 630 778 578 717 540 670 511
36" O.C. 6''
G' 55.7 52.8 61.5 57.5 65.6 60.5 68.3 62.4 6'' 152 mm
69.9 63.7 71.4 64.1 71.9 64.5
36''1415 1-1/2'' 36'' 714 mm1-1/2'' 38 mm
SLRFD 1024 1232 904 1101 820 987 754 902 702 841 664 794 635
24" O.C.
G' 56.2 53.7 62.5 59.0 67.0 62.7 70.2 65.3 72.5 67.1 74.1 68.5 75.2 69.4
SLRFD 1504 1122 1328 1006 1203 926 1110 867 1025 822 965 786 918 757
18" O.C.
G' 56.8 54.3 63.3 60.2 68.0 64.5 71.9 67.6 74.6 69.9 76.9 71.9 78.1 73.5
22
SLRFD 1669 1303 1509 1199 1394 1126 1308 1071 1241 1030 1188 997 1145 970
12" O.C.
G' 57.5 55.7 64.6 62.3 70.2 67.4 74.5 71.4 78.1 74.6 80.6 77.5 83.3 79.4
SLRFD 2076 1739 1959 1666 1874 1614 1809 1575 1759 1545 1501 1501 1216 1216
6" O.C. 36/11
G' 59.2 58.1 67.1 66.1 74.1 72.6 80.0 78.1 84.7 82.6 88.5 87.0 91.7 90.1
SLRFD 2577 2238 2517 2204 2473 2181 2440 2163 1900 1900 1501 1501 1216 1216
3" O.C.
G' 61.0 60.2 69.9 69.4 78.1 77.5 84.7 84.0 6''90.1 89.3 95.2 94.3 100.0 99.0
36'' 1-1/2''
SLRFD 1705 1202 1466 1044 1286 930 1142 842 1034 776 949 725 889 688
36" O.C.
G' 78.5 73.3 84.6 77.7 88.2 80.0 90.1 81.0 91.0 81.2 90.9 81.3 90.9 80.6
SLRFD 1836 1346 1608 1196 1445 1091 1319 1014 1211 953 1126 902 1066 865
24" O.C.
G' 79.5 74.9 86.2 80.2 90.5 83.5 93.2 85.4 94.8 86.6 96.2 87.0 96.2 87.7
SLRFD 1961 1483 1743 1340 1588 1240 1472 1167 1382 1111 1303 1067 1243 1031
18" O.C.
G' 80.0 76.3 87.7 82.6 92.6 86.2 96.2 89.3 98.0 90.9 100.0 92.6 101.0 93.5
20
SLRFD 2190 1734 1995 1607 1855 1517 1749 1451 1667 1401 1602 1360 1548 1328
12" O.C.
G' 81.8 78.5 89.9 85.9 95.8 91.2 100.2 95.1 103.5 98.1 106.4 100.0 107.5 102.0
SLRFD 2737 2315 2601 2231 2502 2171 2427 2126 2368 2092 1956 1956 1584 1584
6" O.C.
G' 84.8 83.0 94.7 92.5 102.5 100.0 108.7 106.1 113.8 111.0 117.6 114.9 122.0 119.0
SLRFD 3369 2932 3305 2897 3259 2873 3224 2854 2475 2475 1956 1956 1584 1584
3" O.C.
G' 88.5 87.0 100.0 99.0 108.7 107.5 117.6 116.3 123.5 122.0 129.9 128.2 135.1 133.3
SLRFD 2060 1456 1774 1267 1570 1136 1399 1032 1268 953 1167 891 1086 842
36" O.C.
G' 123.5 113.6 128.4 115.0 129.6 114.7 129.1 113.2 127.5 111.2 125.5 109.1 123.5 106.4
SLRFD 2222 1634 1949 1454 1754 1329 1609 1237 1488 1167 1387 1111 1306 1061
24" O.C.
G' 126.6 116.3 131.6 120.6 133.9 120.9 134.5 120.8 134.1 120.0 133.0 118.9 131.6 117.6
SLRFD 2375 1803 2116 1632 1930 1513 1792 1426 1684 1359 1599 1306 1525 1263
18" O.C.
G' 128.2 119.0 135.1 123.5 137.0 126.6 138.9 128.2 140.8 128.2 138.9 126.6 138.9 126.6
18
SLRFD 2658 2111 2426 1960 2258 1854 2133 1775 2035 1715 1957 1667 1893 1628
12" O.C.
G' 131.6 123.5 139.3 131.0 144.3 135.2 147.4 138.0 149.4 139.8 150.6 141.0 151.5 140.8
SLRFD 3325 2818 3165 2719 3048 2649 2960 2597 2891 2557 2805 2525 2272 2272
6" O.C.
G' 138.9 133.3 149.5 144.7 157.7 152.6 163.9 158.7 168.7 163.4 172.4 167.2 175.4 169.5
SLRFD 4082 3554 4009 3514 3955 3486 3915 3465 3550 3448 2805 2805 2272 2272
3" O.C.
G' 147.1 144.9 161.3 158.7 172.4 169.5 181.8 178.6 188.7 185.2 196.1 192.3 200.0 196.1
SLRFD 2098 1492 1811 1302 1607 1171 1448 1074 1317 994 1215 932 1133 883
36" O.C.
G' 172.4 153.8 172.4 151.5 170.3 147.8 166.5 143.5 162.2 139.1 157.8 135.0 153.5 131.1
SLRFD 2270 1681 1998 1502 1804 1377 1659 1286 1547 1216 1451 1161 1369 1116
24" O.C.
G' 175.4 158.7 178.6 158.7 177.0 157.2 174.7 154.4 171.7 151.4 168.4 148.5 165.2 145.7
SLRFD 2433 1860 2176 1691 1991 1573 1853 1486 1747 1419 1662 1367 1593 1324
18" O.C.
G' 178.6 163.9 181.8 166.7 181.8 166.7 181.8 163.9 178.6 161.3 178.6 161.3 175.4 158.7
16
SLRFD 2731 2185 2503 2037 2338 1932 2214 1855 2118 1796 2041 1749 1978 1711
12" O.C.
G' 185.2 172.4 192.3 175.4 193.4 179.1 194.4 179.9 194.4 180.1 193.9 179.8 193.0 179.4
SLRFD 3422 2913 3269 2820 3158 2753 3073 2704 3007 2666 2954 2635 2840 2611
6" O.C.
G' 196.1 188.7 208.3 200.0 215.3 206.9 220.4 212.0 224.1 215.8 226.8 218.8 228.9 221.1
SLRFD 4177 3638 4110 3603 4062 3577 4025 3559 3996 3544 3506 3506 2840 2840
3" O.C.
G' 212.8 208.3 227.3 222.2 238.1 232.6 250.0 243.9 256.4 250.0 263.2 256.4 263.2 263.2
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 1/4".
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

38 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
152 mm
36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm

Steel Deck Fastening Systems

X-ENP-19 for Fastening Deck to Structural Steel 1.3

36/5 36/4 914/5

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
Load Resistance Factor Design (LRFD) Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
X-ENP-19 L15 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/7 36/5 914/7
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SLRFD 829 674 727 600 655 548 600 508 552 474 517 448 490 428
36" O.C. 6'' 6'' 152 mm
G' 13.6 9.9 16.3 11.9 18.8 13.8 21.0 15.6 23.0 17.2 24.8 18.7 26.3 20.1
36'' 915 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SLRFD 753 820 687 753 640 703 604 664 576 633 554 607 536
24" O.C.
G' 13.6 9.9 16.4 12.0 19.0 14.0 21.4 15.9 23.5 17.6 25.5 19.3 27.3 20.8
SLRFD 993 823 907 765 845 722 798 690 761 665 732 645 709 629
18" O.C.
G' 13.7 10.0 16.6 12.1 19.2 14.2 21.7 16.1 23.9 17.9 26.0 19.6 28.0 21.3
22
SLRFD 1131 939 1059 894 1007 861 967 836 936 816 911 800 891 787
12" O.C.
G' 13.8 10.0 16.8 12.2 19.5 14.4 22.1 16.4 24.6 18.3 26.8 20.2 29.0 21.9
SLRFD 1416 1151 1376 1130 1346 1115 1324 1104 1307 1095 1293 1087 1216 1081
6" O.C. 36/9 36/7 914/9
G' 14.0 10.1 17.1 12.4 20.0 14.7 22.8 16.8 25.4 18.9 28.0 20.9 30.4 22.8
SLRFD 1416 1151 1376 1130 1346 1115 1324 1104 1307 1095 1293 1087 1216 1081
3" O.C. 6'' 6''
G' 14.1 10.2 17.3 12.6 20.4 14.9 23.3 17.1 152 mm
26.1 19.3 28.8 21.4 31.4 23.5
36'' 1-1/2'' 36'' 914 mm 1-1/2'' 38 mm
SLRFD 1079 881 952 790 862 725 795 676 743 638 696 608 661 582
36" O.C.
G' 21.1 15.4 24.9 18.4 28.3 21.2 31.3 23.6 33.7 25.7 35.8 27.7 37.7 29.4
SLRFD 1198 989 1083 910 1000 852 938 809 890 775 851 748 820 726
24" O.C.
G' 21.2 15.5 25.3 18.7 28.8 21.6 32.1 24.2 34.8 26.6 37.3 28.7 39.5 30.8
SLRFD 1306 1084 1202 1015 1126 964 1069 926 1025 896 990 872 961 853
18" O.C.
G' 21.4 15.6 25.5 18.9 29.2 21.9 32.7 24.6 35.7 27.2 38.5 29.5 41.0 31.7
20
SLRFD 1492 1237 1407 1186 1345 1148 1299 1119 1262 1096 1233 1078 1209 1063
12" O.C. 36/11 36/9 914/11
G' 21.6 15.8 25.9 19.1 29.9 22.3 33.6 25.2 36.9 28.0 40.0 30.6 42.9 33.0
SLRFD 1856 1500 1813 1478 1781 1462 1757 1450 1738 1441 1723 1433 1584 1427
6" O.C. 6'' 6'' 152 mm
G' 22.0 16.0 26.6 19.6 30.9 22.9 35.0 26.2 38.8 29.2 42.4 32.2 45.9 35.0
36'' 1856 1-1/2'' 36'' 714 mm 1-1/2'' 38 mm
SLRFD 1500 1813 1478 1781 1462 1757 1450 1738 1441 1723 1433 1584 1427
3" O.C.
G' 22.3 16.2 27.1 19.9 31.7 23.4 36.1 26.8 40.2 30.1 44.1 33.2 47.8 36.2
SLRFD 1306 1067 1155 959 1047 881 967 823 905 778 856 742 810 713
36" O.C.
G' 38.8 28.8 44.6 33.7 49.3 37.8 53.2 41.2 56.2 44.0 58.5 46.4 60.2 48.3
SLRFD 1453 1201 1316 1106 1217 1038 1143 986 1085 946 1040 914 1002 888
24" O.C.
G' 39.2 29.2 45.5 34.4 50.8 38.9 55.2 42.8 58.8 46.1 61.7 49.1 64.5 51.5
SLRFD 1586 1317 1462 1235 1372 1175 1304 1130 1252 1095 1210 1067 1175 1043
18" O.C. 36/11
G' 39.7 29.5 46.3 35.0 51.8 39.7 56.8 44.1 61.0 47.8 64.5 51.0 67.6 54.1
18
SLRFD 1812 1502 1712 1442 1640 1397 1585 1364 1542 1337 1507 1316 1479 1299
12" O.C. 6''
G' 40.3 30.0 47.4 35.8 53.8 41.0 59.2 45.7 64.1 50.0 68.5 54.0 71.9 57.5
36'' 1-1/2''
SLRFD 2251 1815 2200 1790 2164 1772 2136 1759 2114 1748 2096 1739 2082 1732
6" O.C.
G' 41.5 30.8 49.3 37.1 56.5 42.9 63.3 48.4 69.0 53.5 74.6 58.3 79.4 62.9
SLRFD 2251 1815 2200 1790 2164 1772 2136 1759 2114 1748 2096 1739 2082 1732
3" O.C.
G' 42.4 31.3 51.0 38.2 58.8 44.4 66.2 50.5 73.0 56.2 79.4 61.3 85.5 66.7
SLRFD 1337 1095 1186 987 1079 910 999 853 937 808 888 772 848 743
36" O.C.
G' 62.1 46.9 69.4 53.5 74.6 58.6 78.7 62.4 81.3 65.4 83.3 67.7 84.0 69.5
SLRFD 1492 1235 1356 1142 1259 1075 1185 1025 1129 985 1083 953 1046 928
24" O.C.
G' 63.3 47.8 71.4 55.2 77.5 61.0 82.6 65.7 86.2 69.6 89.3 72.9 91.7 75.6
SLRFD 1632 1355 1510 1276 1422 1218 1356 1174 1304 1140 1263 1113 1229 1090
18" O.C.
G' 64.1 48.8 73.0 56.5 80.0 62.9 86.2 68.5 90.1 73.0 94.3 76.9 97.1 80.0
16
SLRFD 1866 1545 1770 1487 1700 1446 1647 1414 1605 1389 1572 1369 1545 1352
12" O.C.
G' 65.8 49.8 75.8 58.1 84.0 65.7 90.9 72.1 97.1 77.8 102.0 82.8 106.4 87.2
SLRFD 2307 1853 2261 1831 2227 1815 2202 1803 2182 1793 2165 1786 2152 1779
6" O.C.
G' 68.5 51.8 80.0 61.3 90.1 70.2 99.0 78.2 107.5 85.5 114.9 92.1 120.5 98.2
SLRFD 2307 1853 2261 1831 2227 1815 2202 1803 2182 1793 2165 1786 2152 1779
3" O.C.
G' 70.9 53.2 84.0 64.1 96.2 74.1 106.4 82.6 116.3 91.7 125.0 99.0 133.3 106.4
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 1/4".
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 39
6'' 152 mm 152 mm
36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm

Steel Deck Fastening Systems

1.3 X-ENP-19 for Fastening Deck to Structural Steel


c
36/7 914/9 (36/9)
914/9 914/7 (36/7)
914/7

6'' 152 mm 152 mm


36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm
Limit States Design (LSD)- Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
X-ENP-19 L15 fasteners with 914/9 (36/9) or 914/7 (36/7) end and interior support fastener patterns1,2,3,4,5
Span (mm)
Sidelap 1200 1500 1800 2100 2400 2700 3000
Gauge spacing Factor
Hilti SLC6,7,8 Fasteners per sheet to support
36/9 914/11 914/9
9 7 9 7 9 7 9 7 9 7 9 7 9 7
SLSD 18.2 12.7 15.5 11.0 13.5 9.6 11.9 8.7 10.7 8.0 9.9 7.4 9.2 7.0
900 mm o.c.
6'' 152 mm G' 9.7 9.2 10.7 10.0 11.4 10.6 152 mm
11.9 10.9 12.2 11.1 12.5 11.2 12.7 11.4
36'' 1-1/2''
714 mm 38 mm
SLSD 19.4 14.1 16.9 12.4 15.1 11.3 13.6 10.4 12.4914 mm
9.7 11.6 9.138 mm
10.9 8.7
600 mm o.c.
G' 9.8 9.3 10.9 10.3 11.7 10.9 12.3 11.4 12.7 11.8 13.0 12.0 13.2 12.2
SLSD 20.6 15.4 18.2 13.8 16.5 12.7 15.2 11.9 14.1 11.3 13.3 10.8 12.6 10.4
450 mm o.c.
G' 9.8 9.4 11.0 10.5 11.9 11.2 12.5 11.8 13.0 12.2 13.3 12.7 13.7 12.8
22
SLSD 22.9 17.9 20.7 16.5 19.1 15.5 18.0 14.7 17.1 14.1 16.3 13.7 15.7 13.3
300 mm o.c.
G' 10.0 9.7 11.2 10.8 12.2 11.7 13.0 12.5 13.7 13.0 14.1 13.5 14.5 13.9
SLSD 28.4 23.8 26.8 22.8 25.7 22.1 24.8 21.6 24.1 21.2 21.2 20.8 17.2 17.2
36/11
150 mm o.c. 914/11
G' 10.3 10.1 11.7 11.5 12.9 12.6 13.9 13.6 14.7 14.5 15.4 15.2 16.1 15.6
SLSD 35.0 30.4 34.2 29.9 33.6 29.6 33.1 29.3 26.8 26.8 21.2 21.2 17.2 17.2
75 mm o.c.
6'' G' 10.5 10.5 12.2 12.0 13.5 13.5 152 mm
14.7 14.5 15.6 15.6 16.7 16.4 17.5 17.2
36'' SLSD
1-1/2''16.5
23.4 20.1 14.4 17.7 12.8 15.7 11.6 14.2
714 mm
10.7 13.1 10.0
38 mm
12.2 9.5
900 mm o.c.
G' 13.7 12.8 14.8 13.6 15.4 14.0 15.8 14.2 15.9 14.3 15.9 14.3 15.9 14.1
SLSD 25.2 18.5 22.1 16.4 19.9 15.0 18.2 13.9 16.7 13.1 15.5 12.4 14.7 11.9
600 mm o.c.
G' 13.8 13.1 15.0 14.0 15.8 14.6 16.3 15.0 16.6 15.2 16.7 15.4 16.9 15.4
SLSD 26.9 20.4 23.9 18.4 21.8 17.0 20.2 16.0 19.0 15.3 18.0 14.7 17.1 14.2
450 mm o.c.
G' 13.9 13.3 15.2 14.3 16.1 15.2 16.7 15.6 17.2 15.9 17.5 16.1 17.5 16.4
20
SLSD 30.0 23.8 27.4 22.0 25.5 20.8 24.0 19.9 22.9 19.2 22.0 18.7 21.3 18.2
300 mm o.c.
G' 14.2 13.7 15.7 15.0 16.7 15.9 17.5 16.6 18.1 17.2 18.5 17.5 18.9 17.9
SLSD 37.4 31.7 35.6 30.5 34.2 29.7 33.2 29.1 32.4 28.6 27.6 27.6 22.4 22.4
150 mm o.c.
G' 14.7 14.4 16.5 16.1 17.9 17.4 19.0 18.5 19.9 19.4 20.8 20.0 21.3 20.8
SLSD 45.7 39.8 44.9 39.3 44.2 39.0 43.7 38.9 35.0 35.0 27.6 27.6 22.4 22.4
75 mm o.c.
G' 15.4 15.2 17.2 17.2 18.9 18.9 20.4 20.0 21.7 21.3 22.7 22.2 23.3 23.3
SLSD 28.3 20.0 24.4 17.4 21.6 15.6 19.3 14.2 17.5 13.1 16.1 12.3 15.0 11.6
900 mm o.c.
G' 21.7 19.6 22.5 20.2 22.7 20.2 22.7 19.9 22.4 19.6 22.1 19.2 21.7 18.9
SLSD 30.5 22.4 26.8 20.0 24.1 18.3 22.1 17.0 20.5 16.1 19.1 15.3 18.0 14.6
600 mm o.c.
G' 22.2 20.4 23.0 21.0 23.5 21.3 23.6 21.2 23.6 21.1 23.4 20.8 23.3 20.8
SLSD 32.6 24.7 29.1 22.4 26.5 20.8 24.6 19.6 23.1 18.7 22.0 18.0 21.0 17.4
450 mm o.c.
G' 22.2 20.8 23.3 21.7 24.4 22.2 24.4 22.2 24.4 22.2 24.4 22.2 24.4 22.2
18
SLSD 36.4 28.9 33.3 26.9 31.0 25.4 29.3 24.4 27.9 23.6 26.9 22.9 26.0 22.4
300 mm o.c.
G' 22.7 21.7 24.4 22.9 25.3 23.7 25.8 24.2 26.2 24.6 26.4 25.0 26.3 25.0
SLSD 45.5 38.5 43.3 37.2 41.7 36.3 40.5 35.5 39.6 35.0 38.8 34.6 32.1 32.1
150 mm o.c.
G' 23.8 23.3 26.1 25.3 27.6 26.7 28.7 27.8 29.5 28.6 30.2 29.4 30.3 30.3
SLSD 55.4 48.2 54.4 47.7 53.7 47.3 53.1 47.0 50.1 46.8 39.6 39.6 32.1 32.1
75 mm o.c.
G' 25.6 25.0 27.8 27.8 30.3 29.4 31.3 31.3 33.3 32.3 34.5 33.3 34.5 34.5
SLSD 28.8 20.5 24.9 17.9 22.1 16.1 20.0 14.8 18.1 13.7 16.7 12.8 15.6 12.2
900 mm o.c.
G' 30.3 27.0 30.3 26.3 29.9 26.0 29.3 25.3 28.6 24.5 27.8 23.8 27.1 23.2
SLSD 31.2 23.1 27.5 20.7 24.8 19.0 22.8 17.7 21.3 16.7 20.0 16.0 18.9 15.4
600 mm o.c.
G' 30.3 27.8 31.3 27.8 31.1 27.6 30.7 27.2 30.2 26.7 29.7 26.2 29.1 25.7
SLSD 33.4 25.6 29.9 23.3 27.4 21.6 25.5 20.4 24.0 19.5 22.9 18.8 21.9 18.2
450 mm o.c.
G' 31.3 28.6 32.3 29.4 32.3 29.4 32.3 28.6 31.3 28.6 31.3 28.6 31.3 27.8
16
SLSD 37.5 30.0 34.4 28.0 32.1 26.5 30.4 25.5 29.1 24.7 28.1 24.0 27.2 23.5
300 mm o.c.
G' 32.3 30.3 33.3 31.3 33.9 31.4 34.1 31.6 34.2 31.7 34.1 31.6 34.0 31.6
SLSD 46.8 39.9 44.8 38.6 43.2 37.7 42.1 37.0 41.2 36.5 40.5 36.1 39.9 35.8
150 mm o.c.
G' 34.5 33.3 37.0 34.5 37.7 36.2 38.6 37.2 39.3 37.9 39.8 38.4 40.2 38.8
SLSD 56.7 49.4 55.8 48.9 55.2 48.6 54.7 48.3 54.3 48.1 49.5 47.9 40.1 40.1
75 mm o.c.
G' 37.0 35.7 40.0 38.5 41.7 41.7 43.5 43.5 45.5 43.5 45.5 45.5 47.6 45.5
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 6 mm.
2 Tabulated LSD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LSD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

40 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6''152 mm 152 mm
36'' 914 mm1-1/2'' 38 mm 914 mm 38 mm

Steel Deck Fastening Systems

X-ENP-19 for Fastening Deck to Structural Steel 1.3


c
36/4 914/5 (36/5)
914/5 914/4 (36/4)
914/4

6''152 mm 152 mm
36'' 914 mm1-1/2'' 38 mm 914 mm 38 mm
Limit States Design (LSD)- Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
X-ENP-19 L15 fasteners with 914/5 (36/5) or 914/4 (36/4) end and interior support fastener patterns1,2,3,4,5
Span (mm)
Sidelap 1200 1500 1800 2100 2400 2700 3000
Gauge spacing Factor
Hilti 36/5
SLC6,7,8 Fasteners per sheet to support
914/7 914/5
5 4 5 4 5 4 5 4 5 4 5 4 5 4
SLSD 11.4 9.2 10.0 8.2 9.0 7.5 8.3 7.0 7.6 6.5 7.1 6.2 6.7 5.9
900
6''mm
152 o.c.
mm G' 2.3 1.7 2.8 2.1 3.2 2.4 3.6152 mm2.7 4.0 3.0 4.3 3.2 4.6 3.5
36'' 914 mm1-1/2'' 38 mm 914 mm 38 mm
SLSD 12.5 10.3 11.3 9.4 10.3 8.8 9.7 8.3 9.1 7.9 8.7 7.6 8.3 7.4
600 mm o.c.
G' 2.4 1.7 2.8 2.1 3.3 2.4 3.7 2.8 4.1 3.1 4.4 3.3 4.7 3.6
SLSD 13.6 11.3 12.4 10.5 11.6 9.9 11.0 9.5 10.5 9.1 10.1 8.9 9.7 8.6
450 mm o.c.
G' 2.4 1.7 2.9 2.1 3.3 2.5 3.8 2.8 4.1 3.1 4.5 3.4 4.9 3.7
22
SLSD 15.5 12.8 14.5 12.2 13.8 11.8 13.3 11.4 12.8 11.2 12.5 11.0 12.2 10.8
300 mm o.c.
G' 2.4 1.7 2.9 2.1 3.4 2.5 3.8 2.8 4.3 3.2 4.7 3.5 5.0 3.8
SLSD 19.2 15.6 18.7 15.3 18.3 15.1 18.0 15.0 17.7 14.8 17.5 14.7 17.2 14.7
36/7o.c.
150 mm 914/9 914/7
G' 2.4 1.7 2.9 2.1 3.5 2.5 3.9 2.9 4.4 3.3 4.9 3.6 5.3 4.0
SLSD 19.2 15.6 18.7 15.3 18.3 15.1 18.0 15.0 17.7 14.8 17.5 14.7 17.2 14.7
75
6''mm o.c.
152 mm G' 2.4 1.8 3.0 2.2 3.5 2.6 4.0152 mm3.0 4.5 3.3 5.0 3.7 5.4 4.0
36'' 914 mm1-1/2'' 38 mm 914 mm 38 mm
SLSD 14.8 12.1 13.1 10.8 11.8 10.0 10.9 9.3 10.2 8.8 9.6 8.4 9.1 8.0
900 mm o.c.
G' 3.6 2.7 4.3 3.2 4.9 3.7 5.4 4.1 5.8 4.5 6.3 4.8 6.6 5.1
SLSD 16.4 13.6 14.9 12.5 13.7 11.7 12.9 11.1 12.2 10.6 11.7 10.3 11.3 10.0
600 mm o.c.
G' 3.7 2.7 4.4 3.2 5.0 3.7 5.6 4.2 6.1 4.6 6.5 5.0 6.9 5.3
SLSD 17.9 14.8 16.5 13.9 15.4 13.2 14.7 12.7 14.1 12.3 13.6 12.0 13.2 11.7
450 mm o.c.
G' 3.7 2.7 4.4 3.3 5.1 3.8 5.6 4.3 6.2 4.7 6.7 5.1 7.1 5.5
20
SLSD 20.4 16.9 19.3 16.2 18.4 15.7 17.8 15.3 17.3 15.0 16.9 14.8 16.6 14.6
36/9o.c.
300 mm 914/11 914/9
G' 3.7 2.7 4.5 3.3 5.2 3.9 5.8 4.4 6.4 4.8 6.9 5.3 7.5 5.7
SLSD 25.2 20.3 24.6 20.0 24.2 19.8 23.8 19.7 23.6 19.5 23.4 19.4 22.4 19.4
150
6''mm
152 o.c.
mm G' 3.8 2.8 4.6 3.4 5.3 4.0 6.1152 mm4.5 6.7 5.1 7.4 5.6 7.9 6.1
36'' 714 mm1-1/2'' 38 mm 914 mm 38 mm
SLSD 25.2 20.3 24.6 20.0 24.2 19.8 23.8 19.7 23.6 19.5 23.4 19.4 22.4 19.4
75 mm o.c.
G' 3.8 2.8 4.7 3.4 5.5 4.0 6.3 4.6 6.9 5.2 7.6 5.7 8.3 6.3
SLSD 17.9 14.6 15.9 13.2 14.4 12.1 13.3 11.3 12.4 10.7 11.8 10.2 11.2 9.8
900 mm o.c.
G' 6.7 5.0 7.8 5.8 8.5 6.6 9.3 7.2 9.8 7.7 10.2 8.1 10.5 8.5
SLSD 19.9 16.5 18.1 15.2 16.7 14.2 15.7 13.5 14.9 13.0 14.3 12.5 13.8 12.2
600 mm o.c.
G' 6.8 5.1 7.9 6.0 8.8 6.7 9.6 7.4 10.2 8.0 10.8 8.5 11.2 9.0
SLSD 21.7 18.0 20.0 16.9 18.8 16.1 17.9 15.5 17.2 15.0 16.6 14.6 16.1 14.3
450 36/11
mm o.c. 914/11
G' 6.8 5.1 8.0 6.1 9.0 6.9 9.9 7.6 10.6 8.3 11.2 8.9 11.8 9.4
18
SLSD 24.8 20.5 23.4 19.7 22.5 19.1 21.7 18.7 21.1 18.3 20.7 18.0 20.3 17.8
300
6''mm o.c. 152 mm
G' 7.0 5.2 8.2 6.2 9.3 7.1 10.3 7.9 11.1 8.7 11.9 9.4 12.5 10.0
36'' 1-1/2'' 714 mm 38 mm
SLSD 30.6 24.6 29.9 24.3 29.4 24.0 29.0 23.9 28.7 23.7 28.4 23.6 28.2 23.5
150 mm o.c.
G' 7.2 5.3 8.5 6.4 9.8 7.4 11.0 8.4 12.0 9.3 13.0 10.1 13.9 10.9
SLSD 30.6 24.6 29.9 24.3 29.4 24.0 29.0 23.9 28.7 23.7 28.4 23.6 28.2 23.5
75 mm o.c.
G' 7.4 5.4 8.8 6.6 10.2 7.7 11.5 8.7 12.7 9.7 13.7 10.6 14.7 11.5
SLSD 18.4 15.0 16.3 13.6 14.8 12.5 13.7 11.7 12.9 11.1 12.2 10.6 11.7 10.2
900 mm o.c.
G' 10.8 8.1 12.0 9.3 13.0 10.2 13.7 10.9 14.3 11.4 14.5 11.8 14.7 12.2
SLSD 20.5 16.9 18.6 15.7 17.3 14.8 16.3 14.1 15.5 13.5 14.9 13.1 14.4 12.7
600 mm o.c.
G' 11.0 8.3 12.5 9.6 13.5 10.6 14.5 11.5 15.2 12.1 15.6 12.7 16.1 13.2
SLSD 22.4 18.6 20.7 17.5 19.5 16.7 18.6 16.1 17.9 15.6 17.3 15.3 16.9 15.0
450 mm o.c.
G' 11.1 8.4 12.7 9.8 13.9 11.0 14.9 11.9 15.9 12.7 16.4 13.3 16.9 14.1
16
SLSD 25.5 21.1 24.2 20.3 23.3 19.8 22.6 19.4 22.0 19.0 21.6 18.7 21.2 18.5
300 mm o.c.
G' 11.4 8.6 13.2 10.1 14.5 11.4 15.9 12.5 16.9 13.5 17.9 14.4 18.5 15.2
SLSD 31.3 25.2 30.7 24.9 30.2 24.6 29.9 24.5 29.6 24.3 29.4 24.2 29.2 24.1
150 mm o.c.
G' 11.9 8.9 13.9 10.6 15.6 12.2 17.2 13.6 18.5 14.8 20.0 16.0 21.3 17.1
SLSD 31.3 25.2 30.7 24.9 30.2 24.6 29.9 24.5 29.6 24.3 29.4 24.2 29.2 24.1
75 mm o.c.
G' 12.3 9.3 14.5 11.1 16.7 12.8 18.5 14.3 20.0 15.9 21.7 17.2 23.3 18.5
1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf 6 mm.
2 Tabulated LSD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LSD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 41
Steel Deck Fastening Systems

1.3 X-ENP-19 for Fastening Deck to Structural Steel


c
Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada)
Diaphragm Table 36-7 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1, 2, 3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 7.1 8.5 11.2 13.9 7.1 8.5 11.2 13.9 9.2 11.0 14.6 18.2 12.8 15.4 20.3 25.4
1200
Flexibility Factor, F 109 78 51 38 109 78 51 38 104 74 47 34 99 69 43 30
Strength, SLSD 5.6 8.5 8.9 11.3 6.7 8.0 10.6 13.2 8.5 10.2 13.4 16.8 12.2 14.7 19.4 24.3
1500
Flexibility Factor, F 102 75 52 39 98 72 49 37 93 68 45 33 87 62 40 29
Strength, SLSD 5.5 6.7 8.8 11.0 6.3 7.8 10.2 12.7 7.9 9.5 12.6 15.7 11.8 14.2 18.8 23.5
1800
Flexibility Factor, F 94 71 50 38 91 68 47 36 86 64 44 33 79 57 38 28
Strength, SLSD 4.7 5.6 7.5 9.4 5.4 6.6 8.7 10.9 7.5 9.2 12.0 15.0 11.5 13.9 18.3 22.9
2100
Flexibility Factor, F 93 72 52 41 89 68 49 38 82 61 43 33 74 54 37 27
Strength, SLSD 4.7 5.8 7.6 9.5 5.4 6.5 8.6 10.8 7.3 8.7 11.5 14.5 11.3 13.6 18.0 22.6
2400
Flexibility Factor, F 89 69 50 40 85 66 48 38 78 60 42 33 70 52 35 27
Strength, SLSD 4.2 5.1 6.7 8.5 5.3 6.5 8.6 10.8 7.1 8.5 11.2 14.0 11.0 13.4 17.6 22.2
2700
Flexibility Factor, F 89 70 52 42 82 64 47 37 76 58 42 33 66 50 35 26
Strength, SLSD 4.2 5.2 6.8 8.6 4.8 5.8 7.6 9.6 6.8 8.2 10.9 13.6 10.9 13.3 17.4 21.9
3000
Flexibility Factor, F 86 68 51 42 82 65 49 39 73 57 41 33 64 48 34 26

Diaphragm Table 36-4 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1, 2, 3
No. of transverse nails per 900 mm wide deck units=4 (every flute)
Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 5.1 6.1 8.0 10.0 5.1 6.1 8.0 10.0 6.7 8.1 10.7 13.4 8.8 10.7 14.0 17.5
1200
Flexibility Factor, F 582 372 200 123 582 372 200 123 573 364 193 117 565 357 187 111
Strength, SLSD 4.2 5.1 6.7 8.3 5.1 6.1 8.0 10.0 6.3 7.8 10.2 12.7 8.7 10.5 13.7 17.2
1500
Flexibility Factor, F 483 313 173 110 477 307 168 105 469 300 162 100 460 292 155 94
Strength, SLSD 4.3 5.2 6.8 8.6 4.9 6.0 7.9 9.9 6.1 7.4 9.8 12.2 8.6 10.3 13.5 16.9
1800
Flexibility Factor, F 413 270 151 98 407 265 147 94 400 258 141 89 390 249 134 82
Strength, SLSD 3.6 4.5 6.0 7.5 4.3 5.3 6.9 8.7 6.0 7.3 9.5 11.9 8.5 10.2 13.4 16.8
2100
Flexibility Factor, F 368 244 141 93 362 238 136 89 351 228 127 81 340 219 119 74
Strength, SLSD 3.9 4.7 6.2 7.8 4.5 5.4 7.1 8.8 5.9 7.1 9.3 11.6 8.3 10.1 13.3 16.7
2400
Flexibility Factor, F 329 220 128 86 324 215 124 82 314 206 116 75 303 196 107 67
Strength, SLSD 3.4 4.1 5.5 6.9 4.5 5.4 7.2 8.9 5.8 6.9 9.2 11.4 8.3 10.1 13.2 16.6
2700
Flexibility Factor, F 305 206 123 84 294 196 115 77 285 188 107 70 274 178 99 62
Strength, SLSD 3.6 4.3 5.8 7.3 4.1 4.9 6.5 8.1 5.6 6.8 8.9 11.3 8.2 10.0 13.2 16.5
3000
Flexibility Factor, F 280 190 115 79 275 186 111 76 262 174 101 67 251 164 92 59

Diaphragm Table 36-7 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 38 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1, 2, 3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 6.1 7.5 10.1 12.9 6.1 7.5 10.1 12.9 6.9 8.6 11.9 15.6 8.2 10.5 15.0 20.4
1200
Flexibility Factor, F 113 82 54 40 113 82 54 40 112 81 53 40 110 79 52 38
Strength, SLSD 4.8 6.0 8.1 10.3 5.2 6.5 8.9 11.6 5.8 7.3 10.3 13.9 7.2 9.3 13.6 18.9
1500
Flexibility Factor, F 106 79 55 42 106 79 55 42 105 78 54 41 102 76 52 40
Strength, SLSD 4.2 5.3 7.3 9.6 4.6 5.6 8.0 10.7 5.1 6.5 9.3 12.7 6.6 8.6 12.8 17.9
1800
Flexibility Factor, F 103 79 57 45 103 79 56 44 101 77 55 43 98 75 53 41
Strength, SLSD 3.6 4.5 6.2 8.2 3.9 4.8 6.8 9.2 4.5 5.8 8.5 11.8 6.0 8.0 12.1 17.2
2100
Flexibility Factor, F 103 81 60 48 102 80 59 47 100 78 57 46 96 74 54 43
Strength, SLSD 3.3 4.2 5.9 7.9 3.5 4.5 6.3 8.7 4.1 5.3 7.9 11.0 5.6 7.5 11.5 16.6
2400
Flexibility Factor, F 104 83 62 51 103 82 62 50 101 80 60 49 95 75 56 45
Strength, SLSD 2.9 3.6 5.2 7.1 3.3 4.2 6.1 8.3 3.8 4.9 7.4 10.5 5.3 7.2 11.2 16.1
2700
Flexibility Factor, F 106 86 66 54 104 84 64 53 102 82 63 51 96 76 58 47
Strength, SLSD 2.8 3.5 5.1 6.9 2.9 3.8 5.4 7.5 3.5 4.7 7.1 10.0 5.1 6.9 10.8 15.6
3000
Flexibility Factor, F 108 89 69 57 107 88 68 57 104 84 65 54 96 78 59 49
1 The ratio of span of deck unit to average length of sheet is taken to be 1/3.
2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi.
3 Values shown calculated in accordance with SDI equations using a factor of 0.5 for LSD for all load conditions.

Note: Reference pages 40-41 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC).

42 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

X-ENP-19 for Fastening Deck to Structural Steel 1.3


c
Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada)
Diaphragm Table 36-4 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 38 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1,2,3
No. of transverse nails per 900 mm wide deck units=4 (every other flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 4.3 5.4 7.2 9.3 4.3 5.4 7.2 9.3 4.9 6.2 8.7 11.5 6.0 7.6 11.0 14.8
1200
Flexibility Factor, F 589 378 205 128 589 378 205 128 587 377 204 127 584 374 201 124
Strength, SLSD 3.5 4.3 5.9 7.6 3.8 4.8 6.6 8.6 4.3 5.5 7.8 10.5 5.5 7.1 10.3 14.2
1500
Flexibility Factor, F 492 322 180 116 491 321 179 115 489 318 177 114 484 314 174 111
Strength, SLSD 3.2 3.9 5.5 7.4 3.4 4.2 6.1 8.2 3.9 5.1 7.2 9.9 5.2 6.7 10.0 13.7
1800
Flexibility Factor, F 430 285 165 110 428 284 164 109 426 282 162 107 419 276 157 102
Strength, SLSD 2.6 3.3 4.7 6.2 2.8 3.6 5.3 7.2 3.4 4.6 6.8 9.4 4.8 6.3 9.6 13.4
2100
Flexibility Factor, F 388 262 156 107 387 261 155 106 382 257 152 103 374 250 145 97
Strength, SLSD 2.5 3.2 4.6 6.2 2.6 3.4 5.1 7.1 3.2 4.2 6.5 8.9 4.6 6.1 9.3 13.2
2400
Flexibility Factor, F 358 246 150 106 356 244 149 105 351 240 145 101 341 231 138 94
Strength, SLSD 2.2 2.8 4.0 5.5 2.5 3.3 4.8 6.9 3.1 4.0 6.1 8.7 4.5 6.0 9.2 12.9
2700
Flexibility Factor, F 337 235 148 107 333 232 145 104 328 227 141 101 316 216 132 92
Strength, SLSD 2.1 2.7 4.0 5.5 2.2 2.9 4.3 6.1 2.8 3.9 5.9 8.5 4.3 5.8 8.9 12.7
3000
Flexibility Factor, F 320 227 146 107 318 225 145 106 311 218 139 101 297 206 128 91

Diaphragm Table 24-5 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 75 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1,2,3
No. of transverse nails per 600 mm wide deck units=5 (every flute)
Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 4.1 4.9 6.6 8.2 4.7 5.8 7.6 9.5 6.7 8.1 10.7 13.4 10.8 13.2 17.3 21.7
2400
Flexibility Factor, F 190 144 102 79 183 138 96 74 169 125 85 65 154 112 73 54
Strength, SLSD 3.6 4.5 5.8 7.3 4.8 5.9 7.6 9.6 6.6 7.9 10.5 13.2 10.7 12.9 17.0 21.5
2700
Flexibility Factor, F 188 145 105 83 174 132 93 73 161 121 84 64 145 106 71 53
Strength, SLSD 3.8 4.6 6.1 7.6 4.3 5.3 6.9 8.7 6.3 7.8 10.2 12.8 10.6 12.8 16.9 21.3
3000
Flexibility Factor, F 179 139 101 80 172 133 96 75 155 117 82 63 138 102 69 52
Strength, SLSD 3.4 4.2 5.5 6.9 4.5 5.3 7.1 8.8 6.2 7.6 10.0 12.6 10.5 12.7 16.8 21.0
3300
Flexibility Factor, F 179 141 104 84 165 129 93 74 150 114 81 63 132 99 67 51
Strength, SLSD 3.6 4.3 5.8 7.2 4.5 5.4 7.2 8.9 6.2 7.5 9.9 12.5 10.5 12.6 16.7 20.9
3600
Flexibility Factor, F 172 136 101 81 160 125 91 73 146 112 80 63 128 96 66 50
Strength, SLSD 3.3 4.0 5.3 6.7 4.1 5.1 6.6 8.3 6.1 7.4 9.8 12.2 10.3 12.6 16.6 20.8
3900
Flexibility Factor, F 173 138 104 84 160 127 94 75 142 110 79 62 124 93 65 49
Strength, SLSD 3.4 4.2 5.5 6.9 4.2 5.2 6.7 8.5 6.0 7.3 9.6 12.1 10.3 12.5 16.5 20.7
4200
Flexibility Factor, F 168 134 101 82 156 124 92 74 139 108 79 62 120 91 64 49

Diaphragm Table 24-5 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N)
w/X-ENP-19 L15 Metric for 75 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1,2,3
No. of transverse nails per 600 mm wide deck units=5 (every flute)
Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
Deck gauge thickness 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16
Strength, SLSD 2.7 3.4 4.8 6.6 2.9 3.8 5.4 7.3 3.5 4.6 6.8 9.6 5.1 6.8 10.7 15.5
2400
Flexibility Factor, F 226 177 130 104 224 175 128 103 218 170 124 99 206 158 114 90
Strength, SLSD 2.5 3.1 4.3 5.9 2.8 3.5 5.2 7.2 3.3 4.2 6.5 9.3 4.8 6.6 10.5 15.2
2700
Flexibility Factor, F 228 182 136 111 224 177 133 108 217 172 128 103 203 158 116 93
Strength, SLSD 2.4 2.9 4.2 5.9 2.5 3.2 4.7 6.5 3.1 4.1 6.2 9.0 4.6 6.3 10.1 14.9
3000
Flexibility Factor, F 230 185 141 116 227 183 139 114 218 175 132 108 201 159 118 96
Strength, SLSD 2.1 2.7 3.9 5.3 2.4 3.1 4.6 6.5 2.9 3.9 6.0 8.8 4.5 6.2 10.0 14.7
3300
Flexibility Factor, F 235 192 148 123 230 187 144 119 220 178 137 112 201 160 121 99
Strength, SLSD 2.1 2.7 3.9 5.4 2.4 3.1 4.6 6.5 2.8 3.8 5.9 8.6 4.3 6.0 9.8 14.5
3600
Flexibility Factor, F 239 196 153 128 233 191 149 124 223 182 141 117 201 162 123 101
Strength, SLSD 1.9 2.5 3.6 5.1 2.1 2.8 4.2 6.0 2.7 3.6 5.8 8.3 4.2 5.9 9.6 14.2
3900
Flexibility Factor, F 246 204 161 135 239 198 156 131 226 186 146 121 201 164 126 104
Strength, SLSD 1.9 2.5 3.6 5.1 2.1 2.8 4.2 6.0 2.6 3.5 5.6 8.2 4.1 5.8 9.5 14.1
4200
Flexibility Factor, F 250 209 166 140 243 203 161 135 230 191 150 126 202 166 128 106
1 The ratio of span of deck unit to average length of sheet is taken to be 1/3.
2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi.
3 Values shown calculated in accordance with SDI equations using a factor of 0.5 for LSD for all load conditions.

Note: Reference pages 40-41 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC).

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 43
Steel Deck Fastening Systems

1.3 X-ENP-19 for Fastening Deck to Structural Steel

1.3.4 Ordering Information

DX 860-ENP-L Decking System


Tools
Description Notes Qty
Use-on-Demand service provides
DX 860-ENP-L Stand-Up Decking Tool 1 pcs
daily rental

Accessories
Description Notes Qty
Replacement piston and brake
X 860-ENP Piston and Brake Spares Pack 1 pcs
for DX 860-ENP-L

Fasteners (Combos with 40-strip Cartridges)


Description Notes Qty
X-ENP-19 MXR bulk fastener/cartridge combo tf 1/4" (6 mm) 2,000 pcs
X-ENP-19 MXR pallet fastener/cartridge combo tf 1/4" (6 mm) 32,000 pcs

DX 76 Decking System
Tools
Description Notes Qty
DX 76 Hand Held Decking Tool
Includes 10 fastener magazine 1 pcs
with MX76 Magazine

Accessories
Description Notes Qty
MX 76 Magazine Replacement magazine for DX 76-MX 1 pcs
Single fastener baseplate for
X-76-FN-15 1 pcs
DX 76
Replacement piston and stopper for
X-76-P-ENP Piston with stopper 1 pcs
DX 76
X-76-PS Piston Stopper Replacement stopper for DX 76 1 pcs

Fasteners (Combos with 10-strip cartridges)


Description Base Steel Thickness Qty
X-ENP-19 MX bulk fastener/cartridge combo tf 1/4" (6 mm) 1,000 pcs
X-ENP-19 MX pallet fastener/cartridge combo tf 1/4" (6 mm) 32,000 pcs

Fasteners (Non-Combo)
Description Base Steel Thickness Qty
X-ENP-19 L15 Fastener (singles) tf 1/4" (6 mm) 100 pcs

44 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Racing Tip Screw Deck Fastening System 1.4

1.4.1 Product Description 1.4.1 Product Description

1.4.2 Material Specifications


The Hilti Racing Tip fastening system Torque Screwdriver. Loaded with
consists of the Hilti SDT 5 stand-up up to 50 frame fasteners or sidelap 1.4.3 Technical Data
screw fastening system and the S-MD connectors this system can perform 1.4.4 Ordering Information
12-24 x 1-5/8 M HWH5 Racing Tip frame attachment and sidelap
fasteners, which are available in a connections. Contact Hilti for specific
collated version. tool recommendations.

The SDT 5 Decking system can be Hilti S-MD 12-24 x 1-5/8 M HWH5
powered with either the ST 1800 Racing Tip steel deck fasteners
Adjustable Torque Screwdriver or the comply with ANSI/SDI RD1.0, C1.0
ST 1800-A18 Cordless Adjustable and NC1.0 standards.

1.4.2 Material Specifications


Fastener Fastener Fastener
designation material plating
S-MD 12-24 x 1-5/8 M HWH5 Carbon Steel 5 m Zinc1
1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product
Technical Guide Volume 1: Direct Fastening for more information. S-MD 12-24 x 1-5/8 M HWH5

Approvals/Listings
1.4.3 Technical Data
FM (Factory Mutual)
Allowable pullout loads for attachments to steel base material lb (kN)1,3,4 For attaching Class 1 Steel Roof Decks
with 1-60, 1-75 and 1-90 wind uplift
Base material thickness in. (Gauge)
Fastener ratings
0.0598 (16) 0.0747 (14) 0.1046 (12) 1/82 1/42
S-MD 12-24 x 1-5/8 M HWH5 215 (0.96) 265 (1.18) 370 (1.65) 505 (2.25) 505 (2.25)
UL (Underwriters Laboratories)
Fasteners for attaching steel roof deck
1 Unless otherwise noted, allowable load values based upon calculations done in accordance with (uplift and fire classification)
Section E4 of AISI S100 with Fu = 58 ksi.
2 Allowable load values based upon testing performed in ASTM A36 (Fu 58 ksi) plate steel.
3 Allowable tension pullout load values must be compared with allowable tension pullover load values.
Use lesser value.
4 Allowable load values based on safety factor of 3.0 per AISI S100.

Allowable tension pullover and shear bearing loads for attaching steel deck 1,2,3,4

Steel deck gauge (in.)


16 (0.0598) 18 (0.0474) 20 (0.0358) 22 (0.0295) 24 (0.0239)
Fastener
Tension Shear 5
Tension Shear 5
Tension Shear Tension Shear Tension Shear
lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN)
560 620 445 620 335 555 275 400 225 260
S-MD 12-24 x 1-5/8 M HWH5
(2.49) (2.76) (1.98) (2.76) (1.49) (2.47) (1.22) (1.78) (1.00) (1.16)
1 Allowable load values are based upon a safety factor of 3.0 per AISI S100.
2 Allowable load values based upon ASTM A1008, or minimum ASTM A653 SQ33 steel deck.
3 Allowable tension pullover load values based upon calculations done in accordance with Section E4 of AISI S100 with Fu = 45 ksi.
4 Allowable tension pullover load values must be compared with allowable tension pullout load values. Use lesser value.
5 Allowable load value limited by screw fastener shear strength.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 45
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm

Steel Deck Fastening Systems

1.4 Racing Tip Screw Deck Fastening System

36/7 36/5 914/7

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard
1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5
fasteners with 36/7 or 36/5 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
36/9 36/7 914/9
Hilti SLC6,7,8 Fasteners per sheet to support
7 5 7 5 7 5 7 5 7 5 7 5 7 5
S6''
ASD
344 308 299 272 265 247 240 6''
228 221152 mm
212 208 199 197 189
36" O.C. 36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
G' 48.2 13.2 51.6 15.8 53.7 18.0 54.9 20.0 55.5 21.8 55.8 23.4 55.9 24.8
SASD 385 343 342 310 312 286 291 269 272 255 259 244 248 235
24" O.C.
G' 49.9 13.4 54.2 16.0 57.1 18.5 59.2 20.7 60.7 22.7 61.7 24.5 62.5 26.2
SASD 424 374 384 344 355 322 334 306 318 294 306 284 296 275
22 18" O.C.
G' 51.2 13.5 56.2 16.3 59.9 18.8 62.7 21.1 64.8 23.3 66.4 25.3 67.7 27.2
SASD 496 427 460 403 435 385 416 372 402 362 390 353 381 346
12" O.C.
G'36/11 53.3 13.7 59.4 16.5 64.1 19.2 67.8 21.836/970.9 24.1 914/11
73.4 26.4 75.5 28.5
SASD 663 531 639 519 622 510 609 503 600 498 592 493 585 490
6" O.C.
6''
G' 56.9 13.9 64.7 17.0 71.1 19.9 76.4 6''
22.7 81.0152 25.3
mm 85.0 27.8 88.4 30.3
36'' 1-1/2'' 36'' 714 mm
1-1/2'' 38 mm
SASD 463 416 400 365 353 329 318 302 291 278 271 259 256 246
36" O.C.
G' 65.5 20.3 68.2 23.8 69.4 26.8 69.7 29.3 69.5 31.5 69.1 33.3 68.6 34.9
SASD 514 459 454 412 411 378 379 352 353 333 333 317 318 304
24" O.C.
G' 68.3 20.6 72.3 24.4 74.7 27.7 76.1 30.6 76.9 33.2 77.4 35.5 77.6 37.5
SASD 563 499 505 455 464 424 435 400 412 382 394 367 379 355
20 18" O.C.
G' 70.7 20.9 75.7 24.8 79.0 28.4 81.3 31.5 83.0 34.4 84.2 37.0 85.0 39.4
SASD 654 568 601 531 564 505 537 48536/11516 469 499 457 486 446
12" O.C.
G' 74.3 21.2 80.9 25.5 85.7 29.3 89.4 32.8 92.2 36.1 94.5 39.1 96.4 41.9
SASD 872 711 835 691 809 676 789 664
6'' 774 655 762 648 752 642
6" O.C. 36''
G' 80.8 21.8 90.0 26.4 97.3 30.7 103.3 34.7 108.2 38.5 112.4 1-1/2''
42.0 115.9 45.4
SASD 540 484 470 428 422 389 383 359 354 336 331 318 313 301
36" O.C.
G' 97.6 36.5 97.6 41.5 96.3 45.4 94.5 48.4 92.7 50.8 90.8 52.6 89.1 54.2
SASD 606 539 540 488 493 452 459 424 434 403 413 386 395 372
24" O.C.
G' 103.1 37.5 105.0 43.1 105.4 47.7 105.0 51.5 104.3 54.7 103.5 57.4 102.6 59.7
SASD 669 588 606 543 562 509 530 484 505 465 485 449 469 437
18 18" O.C.
G' 107.7 38.2 111.2 44.3 113.0 49.5 113.8 53.9 114.1 57.7 114.2 61.0 114.0 63.9
SASD 784 673 728 636 689 609 660 588 637 573 620 560 605 549
12" O.C.
G' 115.2 39.3 121.2 46.1 125.1 52.0 127.8 57.3 129.7 61.9 131.1 66.0 132.1 69.7
SASD 1046 835 1010 816 984 803 965 793 950 785 938 778 928 773
6" O.C.
G' 129.2 41.0 139.6 48.8 147.4 55.9 153.4 62.3 158.2 68.2 162.2 73.6 165.4 78.6

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") tf 1/4".
2 Tabulated ASD diaphragm shear loads are calculated with a safety factor () of 2.35 for wind loads. To calculate ASD values for load combinations involving
earthquake, multiply values in table by 2.35 and divide by a safety factor () of 2.50. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

46 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6'' 152 mm
36'' 1-1/2'' 914 mm 38 mm

Steel Deck Fastening Systems


EDN IMPERIAL

Racing Tip Screw Deck Fastening System 1.4

36/4 36/3 914/4

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard
1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5
fasteners with 36/4 or 36/3 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
36/5 36/4 914/5
Hilti SLC6,7,8 Fasteners per sheet to support
4 3 4 3 4 3 4 3 4 3 4 3 4 3
6''
SASD
252 212 226 194 207 181 194 171 6''
183152 mm
163 174 157 167 152
36" O.C. 36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
G' 9.7 4.9 11.6 6.0 13.4 7.1 15.1 8.1 16.6 9.0 17.9 10.0 19.2 10.8
SASD 283 233 260 220 244 209 232 201 222 194 214 189 208 185
24" O.C.
G' 9.8 5.0 11.8 6.1 13.7 7.2 15.5 8.2 17.2 9.3 18.7 10.2 20.2 11.2
SASD 310 251 291 240 276 231 265 225 257 220 250 215 244 212
22 18" O.C.
G' 9.8 5.0 12.0 6.1 13.9 7.3 15.8 8.4 17.6 9.4 19.3 10.4 20.8 11.4
SASD 354 276 339 269 329 263 320 259 314 256 309 253 305 251
12" O.C. 36/5 9.6
G'36/7 9.9 5.0 12.1 6.2 14.2 7.4 16.2 8.5 18.1 914/710.6
19.9 21.7 11.7
SASD 429 311 423 309 418 307 415 306 412 305 410 304 408 303
6" O.C.
6''
G' 10.1 5.1 12.4 6.3 14.6 7.5 16.8 8.6 6'' 152 mm
18.8 9.8 20.8 10.9 22.8 12.0
36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
SASD 339 286 301 260 275 241 255 227 239 215 224 206 214 198
36" O.C.
G' 15.0 7.8 17.8 9.5 20.3 11.0 22.4 12.5 24.4 13.8 26.1 15.1 27.6 16.3
SASD 378 314 345 293 321 277 303 265 289 255 278 247 268 241
24" O.C.
G' 15.2 7.9 18.2 9.6 20.9 11.3 23.4 12.8 25.6 14.3 27.7 15.7 29.5 17.1
SASD 413 338 384 320 362 307 346 297 333 289 323 282 315 277
20 18" O.C.
G' 15.4 7.9 18.5 9.7 21.4 11.4 24.0 13.1 26.5 14.6 28.7 16.1 30.8 17.6
36/9 472
SASD 372 449 361 432 352 419 345 40936/7 339 914/9335
401 395 331
12" O.C.
G' 15.6 8.0 18.9 9.9 22.0 11.6 24.9 13.3 27.6 15.0 30.1 16.6 32.5 18.2
6''
SASD
578 425 568 421 560 418 554 415 6''
549152 mm
414 546 412 543 411
6" O.C. 36'' 16.0 1-1/2'' 36'' 1-1/2''
G' 8.1 19.5 10.0 22.8 11.9 26.0 13.7 29.1 15.5 32.0 914 mm
17.2 34.8 18.9 38 mm
SASD 396 332 356 306 327 286 306 270 289 258 276 248 265 240
36" O.C.
G' 27.5 14.9 31.8 17.7 35.3 20.3 38.2 22.6 40.7 24.7 42.7 26.6 44.4 28.3
SASD 446 367 411 346 385 329 366 317 351 307 340 299 330 292
24" O.C.
G' 28.2 15.1 33.0 18.2 37.1 21.0 40.6 23.6 43.7 26.0 46.4 28.3 48.8 30.3
SASD 489 394 458 377 436 364 420 355 407 347 396 340 388 335
18 18" O.C.
G'36/11 28.7 15.3 33.9 18.5 38.4 21.5 42.4 24.3 36/9 26.9
45.9 914/11
49.1 29.4 51.9 31.7
SASD 557 433 535 422 519 414 506 408 497 403 489 399 482 396
12" O.C.
G'
6'' 29.5 15.6 35.0 19.0 40.1 22.2 44.7 25.2 48.9 28.1
6'' 152 mm 52.7 30.8 56.2 33.4
SASD 36'' 673 487 664 1-1/2''
483 657 481 652 479 648 36''477 645 714 mm1-1/2''
476 643 475 38 mm
6" O.C.
G' 30.5 15.9 36.8 19.5 42.6 23.0 48.0 26.3 53.1 29.5 57.8 32.6 62.2 35.6

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") tf 1/4".
2 Tabulated ASD diaphragm shear loads are calculated with a safety factor () of 2.35 for wind loads. To calculate ASD values for load combinations involving
earthquake, multiply values in table by 2.35 and divide by a safety factor () of 2.50. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
36/11

6''
36'' 1-1/2''

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 47
6'' 6'' 152 mm
36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm

Steel Deck Fastening Systems

1.4 Racing Tip Screw Deck Fastening System

36/7 36/5 914/7

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/7 or 36/5 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
36/9 914/9
Hilti SLC6,7,8 Fasteners per sheet to36/7
support
7 5 7 5 7 5 7 5 7 5 7 5 7 5
S6''
LRFD
565 507 491 448 436 405 394 6''
374 363152 mm
348 341 327 324 311
36" O.C. 36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
G' 48.2 13.2 51.6 15.8 53.7 18.0 54.9 20.0 55.5 21.8 55.8 23.4 55.9 24.8
SLRFD 633 563 562 509 513 470 477 441 447 419 425 401 407 386
24" O.C.
G' 49.9 13.4 54.2 16.0 57.1 18.5 59.2 20.7 60.7 22.7 61.7 24.5 62.5 26.2
SLRFD 697 614 631 565 584 530 550 503 523 483 503 466 486 453
22 18" O.C.
G' 51.2 13.5 56.2 16.3 59.9 18.8 62.7 21.1 64.8 23.3 66.4 25.3 67.7 27.2
SLRFD 816 702 756 662 714 633 684 611 660 594 641 581 626 569
12" O.C.
G'36/11 53.3 13.7 59.4 16.5 64.1 19.2 67.8 21.8 36/970.9 24.1 914/11
73.4 26.4 75.5 28.5
SLRFD 1089 873 1050 852 1022 838 1001 826 985 817 972 810 962 805
6" O.C.
6''
G' 56.9 13.9 64.7 17.0 71.1 19.9 76.4 6''
22.7 81.0152 25.3
mm 85.0 27.8 88.4 30.3
36'' 1-1/2'' 36'' 714 mm
1-1/2'' 38 mm
SLRFD 761 684 657 600 579 540 522 495 479 457 445 426 421 404
36" O.C.
G' 65.5 20.3 68.2 23.8 69.4 26.8 69.7 29.3 69.5 31.5 69.1 33.3 68.6 34.9
SLRFD 845 755 745 677 676 621 623 579 580 547 547 521 522 500
24" O.C.
G' 68.3 20.6 72.3 24.4 74.7 27.7 76.1 30.6 76.9 33.2 77.4 35.5 77.6 37.5
SLRFD 925 820 830 748 763 696 714 657 677 627 647 603 623 584
20 18" O.C.
G' 70.7 20.9 75.7 24.8 79.0 28.4 81.3 31.5 83.0 34.4 84.2 37.0 85.0 39.4
SLRFD 1075 933 988 873 927 830 882 79736/11
848 771 820 750 798 734
12" O.C.
G' 74.3 21.2 80.9 25.5 85.7 29.3 89.4 32.8 92.2 36.1 94.5 39.1 96.4 41.9
SLRFD 1434 1168 1372 1135 1329 1110 1297 1092
6'' 1272 1077 1252 1065 1236 1056
6" O.C. 36''
G' 80.8 21.8 90.0 26.4 97.3 30.7 103.3 34.7 108.2 38.5 112.4 1-1/2''
42.0 115.9 45.4
SLRFD 887 796 772 704 693 639 630 590 581 552 544 522 514 495
36" O.C.
G' 97.6 36.5 97.6 41.5 96.3 45.4 94.5 48.4 92.7 50.8 90.8 52.6 89.1 54.2
SLRFD 996 886 887 802 811 742 755 697 712 662 678 635 648 612
24" O.C.
G' 103.1 37.5 105.0 43.1 105.4 47.7 105.0 51.5 104.3 54.7 103.5 57.4 102.6 59.7
SLRFD 1099 967 996 891 923 837 870 796 829 764 797 739 771 718
18 18" O.C.
G' 107.7 38.2 111.2 44.3 113.0 49.5 113.8 53.9 114.1 57.7 114.2 61.0 114.0 63.9
SLRFD 1288 1105 1196 1044 1132 1000 1084 967 1047 941 1018 920 995 903
12" O.C.
G' 115.2 39.3 121.2 46.1 125.1 52.0 127.8 57.3 129.7 61.9 131.1 66.0 132.1 69.7
SLRFD 1719 1372 1659 1341 1617 1319 1585 1302 1561 1289 1541 1279 1526 1270
6" O.C.
G' 129.2 41.0 139.6 48.8 147.4 55.9 153.4 62.3 158.2 68.2 162.2 73.6 165.4 78.6

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") tf 1/4".
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

48 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
6'' 152 mm
36'' 1-1/2'' 914 mm 38 mm

Steel Deck Fastening Systems


EDN IMPERIAL

Racing Tip Screw Deck Fastening System 1.4

36/4 36/3 914/4

6'' 6'' 152 mm


36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G',
(kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy 33 ksi; Fu 45 ksi) installed with Hilti
S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/4 or 36/3 end and interior support fastener patterns1,2,3,4,5
Span (ft- in.)
Sidelap 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 10'-0"
Gauge spacing Factor
36/5 36/4 914/5
Hilti SLC6,7,8 Fasteners per sheet to support
4 3 4 3 4 3 4 3 4 3 4 3 4 3
S6''
LRFD
414 348 371 319 341 298 318 282 6''
300152 mm
268 286 258 274 249
36" O.C. 36'' 1-1/2'' 36'' 1-1/2''
914 mm 38 mm
G' 9.7 4.9 11.6 6.0 13.4 7.1 15.1 8.1 16.6 9.0 17.9 10.0 19.2 10.8
SLRFD 465 384 428 361 401 344 381 330 365 319 352 311 342 304
24" O.C.
G' 9.8 5.0 11.8 6.1 13.7 7.2 15.5 8.2 17.2 9.3 18.7 10.2 20.2 11.2
SLRFD 510 412 477 394 454 380 436 369 422 361 411 354 402 348
22 18" O.C.
G' 9.8 5.0 12.0 6.1 13.9 7.3 15.8 8.4 17.6 9.4 19.3 10.4 20.8 11.4
SLRFD 582 453 558 442 540 433 527 426 516 420 508 416 501 412
12" O.C. 36/5 9.6
G'36/7 9.9 5.0 12.1 6.2 14.2 7.4 16.2 8.5 18.1 914/710.6
19.9 21.7 11.7
SLRFD 705 511 695 507 687 504 682 502 677 501 674 499 671 498
6" O.C.
6''
G' 10.1 5.1 12.4 6.3 14.6 7.5 16.8 8.6 6'' 152 mm
18.8 9.8 20.8 10.9 22.8 12.0
36'' 1-1/2'' 36'' 914 mm
1-1/2'' 38 mm
SLRFD 556 470 495 428 452 396 419 372 393 353 369 338 352 325
36" O.C.
G' 15.0 7.8 17.8 9.5 20.3 11.0 22.4 12.5 24.4 13.8 26.1 15.1 27.6 16.3
SLRFD 621 516 567 482 527 456 498 435 475 419 456 406 441 395
24" O.C.
G' 15.2 7.9 18.2 9.6 20.9 11.3 23.4 12.8 25.6 14.3 27.7 15.7 29.5 17.1
SLRFD 679 555 631 526 595 505 569 488 548 474 531 464 518 455
20 18" O.C.
G' 15.4 7.9 18.5 9.7 21.4 11.4 24.0 13.1 26.5 14.6 28.7 16.1 30.8 17.6
36/9 775
SLRFD 612 737 593 710 578 689 567 67236/7 558 914/9550
659 648 544
12" O.C.
G' 15.6 8.0 18.9 9.9 22.0 11.6 24.9 13.3 27.6 15.0 30.1 16.6 32.5 18.2
S6''
LRFD
950 698 933 692 920 687 910 683 6''
903152 mm
680 897 677 892 675
6" O.C. 36'' 16.0 1-1/2'' 36'' 1-1/2''
G' 8.1 19.5 10.0 22.8 11.9 26.0 13.7 29.1 15.5 32.0 914 mm
17.2 34.8 18.9 38 mm
SLRFD 651 546 585 502 538 470 502 444 475 424 453 408 435 394
36" O.C.
G' 27.5 14.9 31.8 17.7 35.3 20.3 38.2 22.6 40.7 24.7 42.7 26.6 44.4 28.3
SLRFD 732 603 675 568 633 541 602 521 577 505 558 491 542 480
24" O.C.
G' 28.2 15.1 33.0 18.2 37.1 21.0 40.6 23.6 43.7 26.0 46.4 28.3 48.8 30.3
SLRFD 803 647 753 620 717 599 690 583 668 570 651 559 637 550
18 18" O.C.
G'36/11 28.7 15.3 33.9 18.5 38.4 21.5 42.4 24.3 36/9 26.9
45.9 914/11
49.1 29.4 51.9 31.7
SLRFD 916 711 879 694 852 681 832 670 816 662 803 655 793 650
12" O.C.
G'
6'' 29.5 15.6 35.0 19.0 40.1 22.2 44.7 25.2 48.9 28.1
6'' 152 mm 52.7 30.8 56.2 33.4
SLRFD 36'' 1106 799 10911-1/2''
794 1080 790 1072 787 1065 36''785 1060 714 mm1-1/2''
783 1056 781 38 mm
6" O.C.
G' 30.5 15.9 36.8 19.5 42.6 23.0 48.0 26.3 53.1 29.5 57.8 32.6 62.2 35.6

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") tf 1/4".
2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor () of 0.70 for wind loads. To calculate LRFD values for load combinations involving
earthquake, divide values in table by 0.70 and multiply by a phi factor () of 0.65. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
36/11

6''
36'' 1-1/2''

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 49
6'' 152 mm
36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm

Steel Deck Fastening Systems

1.4 Racing Tip Screw Deck Fastening System


c
36/5 914/7 (36/7)
914/7 914/5 (36/5)
914/5

6'' 152 mm 152 mm


36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm
Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
S-MD 12-24 x 1-5/8 M HWH5 fasteners with 914/7 (36/7) or 914/5 (36/5) end and interior support fastener patterns1,2,3,4,5
Span (mm)
Sidelap 1200 1500 1800 2100 2400 2700 3000
Gauge spacing
36/7 Factor
914/9 914/7
Hilti SLC6,7,8 Fasteners per sheet to support
7 5 7 5 7 5 7 5 7 5 7 5 7 5
6'' 152 mm SLSD 7.8 7.0 6.8 6.1 6.0 5.6 152 mm
5.4 5.1 5.0 4.8 4.7 4.5 4.5 4.3
900 mm O.C.
36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm
G' 8.4 2.3 9.0 2.7 9.4 3.1 9.6 3.5 9.7 3.8 9.8 4.1 9.8 4.3
SLSD 8.7 7.7 7.7 7.0 7.1 6.5 6.6 6.1 6.2 5.8 5.8 5.5 5.6 5.3
600 mm O.C.
G' 8.7 2.3 9.5 2.8 10.0 3.2 10.4 3.6 10.6 3.9 10.8 4.3 11.0 4.6
SLSD 9.6 8.4 8.7 7.8 8.0 7.3 7.6 6.9 7.2 6.6 6.9 6.4 6.7 6.2
22 450 mm O.C.
G' 8.9 2.3 9.8 2.8 10.5 3.3 11.0 3.7 11.3 4.0 11.6 4.4 11.9 4.7
SLSD 11.2 9.6 10.4 9.1 9.8 8.7 9.4 8.4 9.1 8.1 8.8 8.0 8.6 7.8
300 mm
36/9O.C. 914/9 4.2
914/11 9.3
G' 2.4 10.3 2.9 11.2 3.3 11.8 3.8 12.4 12.8 4.6 13.2 4.9
SLSD 14.9 11.9 14.4 11.6 14.0 11.4 13.7 11.3 13.5 11.2 13.3 11.1 13.2 11.0
150 mm O.C.
6'' 152 mm G' 9.9 2.4 11.2 2.9 12.4 3.4 152 mm
13.3 3.9 14.1 4.4 14.8 4.8 15.4 5.2
36'' 1-1/2''
714 mm 38 mm 914 mm 38 mm
SLSD 10.5 9.4 9.0 8.2 8.0 7.4 7.2 6.8 6.6 6.3 6.1 5.9 5.8 5.6
900 mm O.C.
G' 11.4 3.5 11.9 4.1 12.2 4.6 12.2 5.1 12.2 5.5 12.2 5.8 12.1 6.1
SLSD 11.6 10.4 10.2 9.3 9.3 8.5 8.6 8.0 8.0 7.5 7.5 7.2 7.2 6.9
600 mm O.C.
G' 11.9 3.6 12.7 4.2 13.1 4.8 13.4 5.3 13.5 5.8 13.6 6.2 13.7 6.5
SLSD 12.7 11.2 11.4 10.3 10.5 9.6 9.8 9.0 9.3 8.6 8.9 8.3 8.6 8.0
20 450 mm O.C.
G' 12.3 3.6 13.2 4.3 13.8 4.9 14.3 5.5 14.6 6.0 14.8 6.4 14.9 6.8
36/11 SLSD 14.7 12.8 13.6 12.0 12.7 11.4 12.1 10.9 914/1110.6
11.6 11.3 10.3 11.0 10.1
300 mm O.C.
G' 13.0 3.7 14.1 4.4 15.0 5.1 15.6 5.7 16.2 6.3 16.6 6.8 16.9 7.3
6'' SLSD 19.6 15.9 18.8 15.5 18.2 15.2 152 mm
17.8 14.9 17.4 14.7 17.2 14.6 16.9 14.4
150 mm O.C.
36'' 1-1/2'' 714 mm 38 mm
G' 14.1 3.8 15.7 4.6 17.0 5.3 18.0 6.0 18.9 6.7 19.7 7.3 20.3 7.9
SLSD 12.2 10.9 10.6 9.7 9.5 8.8 8.7 8.1 8.0 7.6 7.5 7.2 7.1 6.8
900 mm O.C.
G' 17.1 6.3 17.1 7.2 16.9 7.9 16.7 8.4 16.3 8.9 16.0 9.2 15.7 9.5
SLSD 13.7 12.1 12.2 11.0 11.1 10.2 10.4 9.6 9.8 9.1 9.3 8.7 8.9 8.4
600 mm O.C.
G' 18.1 6.5 18.4 7.5 18.5 8.3 18.5 9.0 18.4 9.5 18.2 10.0 18.1 10.4
SLSD 15.1 13.2 13.7 12.2 12.7 11.5 12.0 10.9 11.4 10.5 11.0 10.1 10.6 9.9
18 450 mm O.C.
G' 18.9 6.6 19.5 7.7 19.8 8.6 20.0 9.4 20.1 10.1 20.1 10.6 20.1 11.1
SLSD 17.7 15.1 16.4 14.3 15.5 13.7 14.9 13.2 14.4 12.9 14.0 12.6 13.7 12.4
300 mm O.C.
G' 20.1 6.8 21.2 8.0 21.9 9.0 22.4 10.0 22.8 10.8 23.0 11.5 23.2 12.2
SLSD 23.5 18.7 22.7 18.3 22.1 18.0 21.7 17.8 21.4 17.6 21.1 17.5 20.9 17.3
150 mm O.C.
G' 22.5 7.1 24.4 8.5 25.8 9.7 26.9 10.8 27.7 11.8 28.4 12.8 29.0 13.7

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (1.5 mm) tf 6 mm.
2 Tabulated LSD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LSD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.

50 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
152 mm
914 mm 38 mm

Steel Deck Fastening Systems


EDN IMPERIAL EDN METRIC

Racing Tip Screw Deck Fastening System 1.4


c
36/3 914/4 (36/4)
914/4 914/3 (36/3)
914/3

6'' 152 mm 152 mm


36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm
Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm)
for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy 230 MPa; Fu 310 MPa) installed with Hilti
S-MD 12-24 x 1-5/8 M HWH5 fasteners with 914/4 (36/4) or 914/3 (36/3) end and interior support fastener patterns1,2,3,4,5
Span (mm)
Sidelap 1200 1500 1800 2100 2400 2700 3000
Gauge spacing
36/4 Factor
914/5 914/4
Hilti SLC6,7,8 Fasteners per sheet to support
4 3 4 3 4 3 4 3 4 3 4 3 4 3
6'' 152 mm SLSD 5.7 4.8 5.1 4.4 4.7 4.1 152 mm
4.4 3.9 4.1 3.7 3.9 3.5 3.8 3.4
900 mm
36''O.C. 1-1/2''
914 mm 38 mm 914 mm 38 mm
G' 1.7 0.9 2.0 1.0 2.3 1.2 2.6 1.4 2.9 1.6 3.1 1.7 3.3 1.9
SLSD 6.4 5.2 5.9 4.9 5.5 4.7 5.2 4.5 5.0 4.4 4.8 4.3 4.7 4.2
600 mm O.C.
G' 1.7 0.9 2.0 1.1 2.4 1.2 2.7 1.4 3.0 1.6 3.2 1.8 3.5 1.9
SLSD 7.0 5.6 6.5 5.4 6.2 5.2 6.0 5.1 5.8 4.9 5.6 4.8 5.5 4.8
22 450 mm O.C.
G' 1.7 0.9 2.1 1.1 2.4 1.3 2.7 1.4 3.0 1.6 3.3 1.8 3.6 2.0
SLSD 7.9 6.2 7.6 6.0 7.4 5.9 7.2 5.8 7.1 5.7 6.9 5.7 6.9 5.6
30036/5
mm O.C. 914/5 1.7
G'914/7 1.7 0.9 2.1 1.1 2.5 1.3 2.8 1.5 3.1 3.5 1.8 3.8 2.0
SLSD 9.6 6.9 9.5 6.9 9.4 6.9 9.3 6.8 9.2 6.8 9.2 6.8 9.1 6.8
150 mm O.C.
6'' 152 mm G' 1.7 0.9 2.1 1.1 2.5 1.3 152 mm
2.9 1.5 3.3 1.7 3.6 1.9 3.9 2.1
36'' 1-1/2''
914 mm 38 mm 914 mm 38 mm
SLSD 7.6 6.4 6.8 5.9 6.2 5.4 5.8 5.1 5.4 4.8 5.1 4.6 4.8 4.5
900 mm O.C.
G' 2.6 1.3 3.1 1.6 3.5 1.9 3.9 2.2 4.2 2.4 4.5 2.6 4.8 2.8
SLSD 8.5 7.1 7.8 6.6 7.2 6.2 6.8 6.0 6.5 5.7 6.3 5.6 6.1 5.4
600 mm O.C.
G' 2.6 1.4 3.1 1.7 3.6 1.9 4.1 2.2 4.4 2.5 4.8 2.7 5.1 3.0
SLSD 9.3 7.6 8.6 7.2 8.2 6.9 7.8 6.7 7.5 6.5 7.3 6.3 7.1 6.2
20 450 mm O.C.
G' 2.7 1.4 3.2 1.7 3.7 2.0 4.2 2.3 4.6 2.5 5.0 2.8 5.4 3.0
36/7 914/9 10.6
SLSD 8.3 10.1 8.1 9.7 7.9 9.4 7.7 914/7 7.6
9.2 9.0 7.5 8.9 7.4
300 mm O.C.
G' 2.7 1.4 3.3 1.7 3.8 2.0 4.3 2.3 4.8 2.6 5.2 2.9 5.6 3.1
6'' 152 mm SLSD 12.9 9.5 12.7 9.4 12.5 9.3 152 mm
12.4 9.3 12.3 9.2 12.2 9.2 12.2 9.2
150 mm O.C.
36'' 1-1/2''
914 2.8
mm 914 mm 38 mm
G' 1.4 3.438 mm
1.7 3.9 2.1 4.5 2.4 5.0 2.7 5.5 3.0 6.0 3.3
SLSD 8.9 7.5 8.0 6.9 7.4 6.4 6.9 6.1 6.5 5.8 6.2 5.6 6.0 5.4
900 mm O.C.
G' 4.8 2.6 5.5 3.1 6.1 3.5 6.7 3.9 7.1 4.3 7.5 4.6 7.8 4.9
SLSD 10.0 8.2 9.3 7.8 8.7 7.4 8.3 7.1 7.9 6.9 7.7 6.7 7.4 6.6
600 mm O.C.
G' 4.9 2.6 5.7 3.2 6.4 3.6 7.1 4.1 7.6 4.5 8.1 4.9 8.5 5.3
SLSD 11.0 8.8 10.3 8.5 9.8 8.2 9.5 8.0 9.2 7.8 8.9 7.6 8.7 7.5
18 450 mm O.C.
36/9 914/11 5.0
G' 2.7 5.9 3.2 6.7 3.7 7.4 4.2 914/9 4.7
8.0 8.5 5.1 9.0 5.5
SLSD 12.5 9.7 12.0 9.5 11.7 9.3 11.4 9.1 11.2 9.0 11.0 8.9 10.8 8.9
300 mm O.C.
6'' 152 mm G' 5.1 2.7 6.1 3.3 7.0 3.8 7.8 4.4
152 mm 8.5 4.9 9.2 5.3 9.8 5.8
36'' 1-1/2''
SLSD 71415.1
mm 10.9 14.938 mm
10.8 14.7 10.7 14.6 10.7 14.591410.7
mm 14.4 10.638 mm
14.4 10.6
150 mm O.C.
G' 5.3 2.8 6.4 3.4 7.4 4.0 8.3 4.5 9.2 5.1 10.0 5.6 10.8 6.2

1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (1.5 mm) tf 6 mm.
2 Tabulated LSD diaphragm shear loads are calculated with a phi factor () of 0.65 for wind loads. To calculate LSD values for load combinations involving
earthquake, divide values in table by 0.65 and multiply by a phi factor () of 0.60. Panel buckling has been checked.
3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.
36/11 914/11

6'' 152 mm
36'' 1-1/2'' 714 mm 38 mm

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 51
Steel Deck Fastening Systems

1.4 Racing Tip Screw Deck Fastening System

1.4.4 Ordering Information

Racing Tip Screw Fastening System


SDT 5 Stand Up Decking System*
Description Package contents
ST 1800 Metal Construction Includes tool with depth gauge, 13 ft supply cord and operating
Screwdriver instructions in a cardboard box

Includes stand up tool, 2 grips, magazine, 5/16" nutsetter,


SDT 5 Stand Up Decking Tool
supply cord strain relief clasp and operating instructions

* Additional tool and fastener packages available. Contact Hilti for more information.

Accessories
Description Notes Qty
For use with the SDT 5 Stand Up
SDT 5 Magazine 1
Decking Tool
For use with the SDT 5 or SDT 30
SDT Integrated Driver and Setter - 5/16" 1
Stand Up Decking Tools

For attachment of metal deck to bar joist


Max. drill
Description capacity Qty

S-MD 12-24 x 1 5/8" M HWH5 0.500" 250

52 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

SLC Sidelap Connectors for Fastening Deck-to-Deck 1.5

1.5.1 Product Description 1.5.1 Product Description

1.5.2 Material Specifications


The Hilti sidelap fastening system screw driver provides for a completely
consists of a stand up tool (SDT 5), stand-up and cordless deck attachment. 1.5.3 Technical Data
an electric screwdriver (ST 1800) and 1.5.4 Ordering Information
When compared with fastening
collated sidelap connectors.
individual, non-collated, screws, the
For nestable steel deck profiles, the tool SDT 5 offers the installer the capability
of choice is the SDT 5. It uses the ST to work upright. By improving the S-SLC 01 M HWH
1800 electric or ST 1800-A18 battery comfort and health of the installer, Collated Sidelap Connectors
screwdriver to drive sidelap connectors productivity remains high all day,
through sidelaps ranging from 16 to helping keep the project on time and
26 gauge in thickness. Featuring an on budget.
adjustable torque clutch, the ST 1800
Hilti steel deck sidelap fasteners
or ST 1800-A18 helps ensure proper
comply with ANSI/SDI RD1.0, C1.0
fastening while minimizing overdrive.
and NC1.0 standards.
When used with the SDT 5 and Hilti's
S-SLC 01 M HWH
DX 860 tools, the ST 1800-A18 cordless
Sidelap Connector

1.5.2 Material Specifications


Fastener Fastener S-SLC 02 M HWH
Fastener
material plating Collated Sidelap Connectors
S-SLC 01 M HWH Carbon Steel 5 m Zinc1
S-SLC 02 M HWH Carbon Steel 5 m Zinc2
Hilti #10 HWH Screw Carbon Steel 5 m Zinc2
1 EN/ISO 4042 A/3/E. Reference Hilti North American Product Technical Guide Volume 1: Direct Fastening
Section 2.3.3.1 for more information.
2 Minimum requirements of ASTM F1941. Reference Hilti North American Product Technical Guide Volume
1: Direct Fastening Section 2.3.3.1 for more information.

1.5.3 Technical Data


Allowable tension (pullout or pullover) and shear bearing loads for Hilti SLC
Sidelap Connectors1,2,3
Sheet Steel Gauge S-SLC 02 M HWH
22 to 22 20 to 20 18 to 18 16 to 16 Sidelap Connectors
Fastener
Tension Shear Tension Shear Tension Shear Tension Shear Approvals/Listings
lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) ICC-ES (International Code Council)
105 240 120 290 150 385 ESR-2776 (AC43 for S-SLC 01
S-SLC 01 M HWH4,5 and S-SLC 02)
(0.47) (1.07) (0.53) (1.29) (0.67) (1.71)
ESR-2197 (AC43 for #10 HWH Screws)
85 240 100 290 130 385 165 485 ESR-2196 (AC118 for S-SLC 02
S-SLC 02 M HWH5
(0.38) (1.07) (0.44) (1.29) (0.58) (1.71) (0.73) (2.16) and #10 HWH Screws)
Hilti #10 70 210 85 255 115 340 145 430 COLA (City of Los Angeles)
HWH Screw6 RR 25877, RR 25678, RR 25296
(0.31) (0.93) (0.38) (1.13) (0.51) (1.51) (0.64) (1.91)
FM (Factory Mutual)
1 Based upon attachment of two-same thickness layers of ASTM A1008 or minimum ASTM A653 SQ33 S-SLC 01 M HWH and S-SLC 02 M HWH
steel deck. fasteners for securing Class 1 Steel Roof
2 Allowable capacities based on a safety factor of 3.0. Deck sidelaps with 1-60 and 1-90 wind
3 Allowable tension capacities based upon the controlling capacity of pullout, pullover or fastener tension uplift ratings.
strength. S-SLC 02 M HWH listed for higher
4 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength wind uplift ratings with FM Approved
(45 Fu 65 ksi) steel deck. For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use Lightweight Insulating Concrete Roof
S-SLC 02 M HWH.
Deck Assemblies. Refer to FM RoofNav
5 Allowable shear capacities calculated according to Section 4.5 of SDI DDM03 for standard No. 12 screw.
for specific assembly listings.
For shear capacities when used in diaphragm applications in combination with Hilti deck frame fasteners,
reference Qs values in Table 8 in Section 1.1.8.
6 Allowable shear capacities calculated according to Section 4.5 of SDI DDM03 for standard No. 10 screw.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 53
Steel Deck Fastening Systems

1.5 SLC Sidelap Connectors for Fastening Deck-to-Deck

1.5.4 Ordering Information


SDT Stand-Up Decking Tool System
Tools
Description Notes Qty
Includes tool with depth gauge, 13 ft
ST 1800 Adjustable Torque Screwdriver 1 pcs
supply Cord and operating instructions
Includes tool, (2) B 18 Li-Ion 3.3-Ah CPC batteries,
ST 1800-A18 Adjustable Torque
(1) C 4/36-ACS LI TPS charger and operating 1 pcs
Cordless Screwdriver
instructions in a Hilti soft tool bag
SDT 5 Stand Up Tool (for use with the Includes stand up tool, 2 grips, magazine, bit holder,
1 pcs
ST 1800 or ST 1800-A18) nut setter, supply cord strain relief
Accessories
Description Notes Qty
SDT 5 Magazine Replacement magazine for SDT 5 1 pcs
SDT Integrated Driver and Setter Single piece design for SDT 5 1 pcs
Sidelap Connectors (Combos including ST 1800 or ST 1800-A18 and SDT 30)
Description Notes Qty
SDT 5, ST 1800 and 10,000 Sidelap Can include collated connector
10,000 pcs
Connectors choices below
SDT 5, ST 1800 and 25,000 Sidelap Can include collated connector
25,000 pcs
Connectors choices below
SDT 5, ST 1800 and 50,000 Sidelap Can include collated fastener connector
50,000 pcs
Connectors choices below
SDT 5, ST 1800 and 100,000 Sidelap
Can include collated connector choices below 100,000 pcs
Connectors
ST 1800-A18, SDT 5 and 15,000 Sidelap
Can include collated connector choices below 15,000 pcs
Connectors
Sidelap Connectors (Collated)*
Description Deck Thickness (GA) Qty
S-SLC 01 M HWH 181, 20, 22, 24, 26 250
S-SLC 02 M HWH 16, 18, 20, 22 250
#10 HWH Screw 18, 20, 22, 24,26 250
1 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength (45 Fu 65 ksi)
steel deck. For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH.

54 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Optimized Diaphragm Shear Tables 1.6


Span = 4'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
272 289 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/4-48 36/4-48 36/4-48 36/4-48
291 309 36/3-48 36/3-48 36/3-48 36/3-48 36/3-33 36/3-48 36/4-48 36/4-48 36/4-48 36/4-48
311 331 36/3-42 36/3-48 36/3-48 36/3-48 36/3-24 36/3-48 36/4-48 36/4-36 36/4-48 36/4-48
333 354 36/3-30 36/3-48 36/3-48 36/3-48 36/3-18 36/3-48 36/4-48 36/4-24 36/4-48 36/4-48
356 379 36/3-24 36/3-48 36/3-48 36/3-48 36/3-15 36/3-48 36/4-48 36/4-20 36/4-48 36/4-48
381 406 36/3-18 36/3-48 36/3-48 36/3-48 36/4-24 36/3-36 36/4-48 36/4-18 36/4-48 36/4-48
408 434 36/3-14 36/3-42 36/3-48 36/3-48 36/4-18 36/3-27 36/4-48 36/4-14 36/4-48 36/4-48
437 464 36/4-20 36/3-30 36/3-48 36/3-48 36/4-15 36/3-21 36/4-48 36/4-12 36/4-36 36/4-48
467 497 36/4-18 36/3-20 36/3-48 36/3-48 36/4-12 36/3-15 36/4-48 36/5-16 36/4-24 36/4-42
500 532 36/4-14 36/3-18 36/3-36 36/3-42 36/5-18 36/3-12 36/4-48 36/5-14 36/4-20 36/4-36
535 569 36/4-12 36/4-24 36/3-24 36/3-30 36/5-14 36/4-21 36/4-45 36/9-48 36/4-18 36/4-24
572 609 36/5-16 36/4-20 36/3-20 36/3-24 36/5-12 36/4-16 36/4-33 36/9-48 36/4-14 36/4-20
612 651 36/5-14 36/4-18 36/3-16 36/3-18 36/5-9 36/4-14 36/4-27 36/9-30 36/4-12 36/4-18
655 697 36/5-10 36/4-14 36/4-24 36/3-14 36/5-8 36/5-20 36/4-21 36/9-20 36/5-18 36/4-14
701 746 36/5-8 36/4-12 36/4-20 36/4-24 36/5-6 36/4-9 36/4-18 36/9-16 36/5-14 36/4-12
750 798 36/5-7 36/5-16 36/4-18 36/4-18 36/9-18 36/5-12 36/4-15 36/9-12 36/5-12 36/5-18
802 854 36/9-24 36/5-14 36/4-14 36/4-16 36/9-14 36/5-9 36/4-12 36/9-10 36/9-42 36/5-14
859 914 36/9-18 36/5-10 36/5-20 36/4-12 36/9-10 36/9-42 36/4-9 36/9-8 36/9-30 36/5-12
919 977 36/9-12 36/5-8 36/5-16 36/5-18 36/9-9 36/5-6 36/5-12 36/9-7 36/9-20 36/7-16
983 1046 36/9-10 36/5-7 36/5-14 36/5-14 36/9-7 36/9-20 36/5-11 36/11-8 36/9-16 36/9-24
1052 1119 36/9-8 36/5-6 36/5-10 36/5-12 36/9-6 36/9-16 36/5-9 36/11-7 36/9-12 36/9-20
1126 1197 36/9-7 36/9-16 36/5-8 36/5-10 36/11-7 36/9-12 36/5-7 36/11-6 36/9-10 36/7-10
1204 1281 36/9-5 36/9-12 36/5-7 36/5-8 36/11-6 36/9-10 36/5-6 36/9-8 36/9-12
1289 1371 36/11-7 36/9-10 36/9-20 36/9-24 36/9-3 36/9-8 36/9-15 36/9-7 36/9-10
1379 1467 36/11-5 36/9-8 36/9-16 36/9-18 36/11-4 36/9-6 36/9-12 36/9-6 36/9-8
1475 1570 36/11-4 36/9-7 36/9-12 36/9-14 36/11-3 36/11-8 36/9-9 36/11-7 36/9-7
1689 1797 36/11-3 36/11-7 36/9-8 36/9-8 36/9-3 36/9-7 36/11-7
1934 2057 36/11-4 36/9-5 36/9-6 36/11-3 36/11-7
2214 2355 36/11-3 36/11-5 36/11-6 36/11-4
2535 2697 36/11-3 36/11-4 36/11-3

* Please refer to footnotes listed at the end of this section on page 60.
Span = 4'-6''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
254 270 36/3-54 36/3-54 36/3-54 36/3-54 36/3-51 36/3-54 36/4-54 36/4-54 36/4-54 36/4-54
272 289 36/3-54 36/3-54 36/3-54 36/3-54 36/3-36 36/3-54 36/4-54 36/4-48 36/4-54 36/4-54
291 309 36/3-42 36/3-54 36/3-54 36/3-54 36/3-27 36/3-54 36/4-54 36/4-36 36/4-54 36/4-54
311 331 36/3-30 36/3-54 36/3-54 36/3-54 36/3-21 36/3-54 36/4-54 36/4-30 36/4-54 36/4-54
333 354 36/3-24 36/3-54 36/3-54 36/3-54 36/3-16 36/3-54 36/4-54 36/4-24 36/4-54 36/4-54
356 379 36/3-20 36/3-54 36/3-54 36/3-54 36/3-12 36/3-39 36/4-54 36/4-20 36/4-54 36/4-54
381 406 36/3-16 36/3-42 36/3-54 36/3-54 36/4-20 36/3-30 36/4-54 36/4-16 36/4-48 36/4-54
408 434 36/4-24 36/3-30 36/3-54 36/3-54 36/4-16 36/3-24 36/4-54 36/4-14 36/4-36 36/4-54
437 464 36/4-18 36/3-24 36/3-54 36/3-54 36/4-14 36/3-18 36/4-54 36/5-18 36/4-30 36/4-48
467 497 36/4-16 36/3-20 36/3-42 36/3-42 36/5-18 36/3-15 36/4-54 36/5-14 36/4-24 36/4-36
500 532 36/4-12 36/3-16 36/3-30 36/3-36 36/5-16 36/4-21 36/4-45 36/5-12 36/4-20 36/4-30
535 569 36/5-18 36/4-24 36/3-24 36/3-24 36/5-12 36/4-18 36/4-36 36/9-42 36/4-16 36/4-24
572 609 36/5-14 36/4-20 36/3-20 36/3-20 36/5-10 36/4-15 36/4-30 36/9-30 36/4-14 36/4-20
612 651 36/5-12 36/4-16 36/3-14 36/3-16 36/5-9 36/4-12 36/4-24 36/9-20 36/5-18 36/4-18
655 697 36/5-10 36/4-12 36/4-24 36/4-24 36/5-7 36/5-16 36/4-20 36/9-18 36/5-16 36/4-14
701 746 36/5-8 36/5-18 36/4-18 36/4-20 36/5-6 36/5-14 36/4-15 36/9-14 36/5-12 36/5-20
750 798 36/5-7 36/5-14 36/4-16 36/4-18 36/9-15 36/5-12 36/4-12 36/9-10 36/9-42 36/5-16
802 854 36/9-18 36/5-12 36/4-12 36/4-14 36/9-12 36/5-10 36/5-18 36/9-8 36/9-30 36/5-14
859 914 36/9-14 36/5-10 36/5-18 36/4-12 36/9-9 36/5-7 36/5-15 36/9-7 36/9-20 36/9-36
919 977 36/9-10 36/5-8 36/5-14 36/5-16 36/9-8 36/9-19 36/5-12 36/9-6 36/9-18 36/7-14
983 1046 36/9-8 36/5-7 36/5-12 36/5-12 36/9-6 36/9-16 36/5-10 36/11-7 36/9-14 36/7-12
1052 1119 36/9-7 36/9-18 36/5-10 36/5-10 36/9-5 36/9-12 36/5-8 36/11-6 36/9-12 36/9-18
1126 1197 36/9-6 36/9-14 36/5-8 36/5-8 36/11-6 36/9-10 36/5-6 36/9-8 36/9-14
1204 1281 36/9-5 36/9-10 36/5-7 36/5-7 36/9-3 36/9-8 36/9-15 36/9-8 36/9-12
1289 1371 36/11-6 36/9-8 36/9-16 36/9-18 36/9-3 36/9-7 36/9-12 36/9-6 36/9-10
1379 1467 36/11-5 36/9-7 36/9-12 36/9-14 36/11-3 36/9-6 36/9-9 36/11-8 36/9-8
1579 1679 36/11-3 36/9-5 36/9-8 36/9-10 36/11-6 36/9-7 36/11-8
1807 1923 36/11-5 36/9-6 36/9-6 36/11-4 36/11-7
2069 2201 36/11-3 36/11-6 36/11-6 36/11-5
2369 2520 36/11-4 36/11-4 36/11-3

* Please refer to footnotes listed at the end of this section on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 55
Steel Deck Fastening Systems

1.6 Optimized Diaphragm Shear Tables


Span = 5'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
237 253 36/3-60 36/3-60 36/3-60 36/3-60 36/3-51 36/3-60 36/4-60 36/4-60 36/4-60 36/4-60
254 270 36/3-60 36/3-60 36/3-60 36/3-60 36/3-39 36/3-60 36/4-60 36/4-48 36/4-60 36/4-60
272 289 36/3-48 36/3-60 36/3-60 36/3-60 36/3-30 36/3-60 36/4-60 36/4-36 36/4-60 36/4-60
291 309 36/3-36 36/3-60 36/3-60 36/3-60 36/3-24 36/3-60 36/4-60 36/4-30 36/4-60 36/4-60
311 331 36/3-30 36/3-60 36/3-60 36/3-60 36/3-20 36/3-57 36/4-60 36/4-24 36/4-60 36/4-60
333 354 36/3-24 36/3-60 36/3-60 36/3-60 36/3-16 36/3-45 36/4-60 36/4-20 36/4-60 36/4-60
356 379 36/3-18 36/3-48 36/3-60 36/3-60 36/3-12 36/3-35 36/4-60 36/4-18 36/4-48 36/4-60
381 406 36/3-14 36/3-36 36/3-60 36/3-60 36/4-18 36/3-27 36/4-60 36/5-24 36/4-36 36/4-60
408 434 36/3-12 36/3-30 36/3-60 36/3-60 36/4-15 36/3-21 36/4-60 36/5-20 36/4-30 36/4-48
437 464 36/4-18 36/3-24 36/3-42 36/3-48 36/4-12 36/3-18 36/4-60 36/5-16 36/4-24 36/4-36
467 497 36/4-14 36/3-18 36/3-36 36/3-36 36/4-11 36/3-14 36/4-48 36/5-14 36/4-20 36/4-30
500 532 36/4-12 36/3-14 36/3-24 36/3-30 36/4-9 36/4-20 36/4-39 36/5-12 36/4-18 36/4-24
535 569 36/5-16 36/3-12 36/3-20 36/3-24 36/5-12 36/4-16 36/4-30 36/9-30 36/4-16 36/4-24
572 609 36/5-12 36/4-18 36/3-18 36/3-20 36/5-10 36/4-14 36/4-24 36/9-24 36/5-20 36/4-20
612 651 36/5-10 36/4-14 36/3-14 36/3-16 36/5-8 36/4-12 36/4-21 36/9-18 36/5-16 36/4-16
655 697 36/5-8 36/4-12 36/4-20 36/3-12 36/5-6 36/5-16 36/4-18 36/9-14 36/5-14 36/4-14
701 746 36/5-8 36/5-16 36/4-18 36/4-18 36/9-15 36/5-12 36/4-15 36/9-12 36/5-12 36/5-18
750 798 36/9-18 36/5-14 36/4-14 36/4-16 36/9-12 36/5-11 36/4-12 36/9-10 36/9-30 36/5-14
802 854 36/9-14 36/5-12 36/4-12 36/4-14 36/9-10 36/5-9 36/5-15 36/9-8 36/9-24 36/5-12
859 914 36/9-12 36/5-10 36/5-16 36/5-18 36/9-8 36/5-7 36/5-14 36/9-7 36/9-18 36/7-16
919 977 36/9-10 36/5-8 36/5-14 36/5-14 36/9-7 36/5-6 36/5-12 36/9-6 36/9-14 36/7-14
983 1046 36/9-8 36/5-7 36/5-10 36/5-12 36/9-6 36/9-14 36/5-9 36/11-7 36/9-12 36/7-12
1052 1119 36/9-7 36/9-14 36/5-8 36/5-10 36/11-7 36/9-10 36/7-12 36/11-6 36/9-10 36/9-16
1126 1197 36/11-8 36/9-12 36/5-8 36/5-8 36/11-6 36/9-9 36/7-10 36/9-8 36/9-12
1204 1281 36/11-6 36/9-10 36/9-18 36/5-7 36/9-3 36/9-8 36/9-15 36/9-7 36/9-10
1289 1371 36/9-4 36/9-8 36/9-14 36/9-16 36/11-4 36/9-6 36/9-12 36/9-6 36/9-8
1475 1570 36/11-4 36/9-6 36/9-10 36/9-10 36/11-3 36/11-6 36/9-8 36/11-6 36/9-6
1689 1797 36/9-4 36/9-7 36/9-7 36/11-4 36/9-6 36/11-6
1934 2057 36/11-4 36/9-5 36/9-5 36/11-3 36/11-6
2214 2355 36/11-3 36/11-5 36/11-5 36/11-4

* Please refer to footnotes listed at the end of this section on page 60.
Span = 5'-6''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
222 236 36/3-66 36/3-66 36/3-66 36/3-66 36/3-57 36/3-66 36/4-66 36/4-60 36/4-66 36/4-66
237 253 36/3-66 36/3-66 36/3-66 36/3-66 36/3-42 36/3-66 36/4-66 36/4-48 36/4-66 36/4-66
254 270 36/3-48 36/3-66 36/3-66 36/3-66 36/3-33 36/3-66 36/4-66 36/4-42 36/4-66 36/4-66
272 289 36/3-42 36/3-66 36/3-66 36/3-66 36/3-27 36/3-66 36/4-66 36/4-30 36/4-66 36/4-66
291 309 36/3-30 36/3-66 36/3-66 36/3-66 36/3-21 36/3-63 36/4-66 36/4-24 36/4-66 36/4-66
311 331 36/3-24 36/3-60 36/3-66 36/3-66 36/3-18 36/3-48 36/4-66 36/4-24 36/4-60 36/4-66
333 354 36/3-20 36/3-48 36/3-66 36/3-66 36/3-15 36/3-39 36/4-66 36/4-20 36/4-48 36/4-66
356 379 36/3-18 36/3-42 36/3-66 36/3-66 36/3-12 36/3-30 36/4-66 36/4-16 36/4-42 36/4-60
381 406 36/3-14 36/3-30 36/3-60 36/3-66 36/4-16 36/3-24 36/4-66 36/4-14 36/4-36 36/4-48
408 434 36/4-18 36/3-24 36/3-48 36/3-48 36/4-14 36/3-21 36/4-66 36/5-18 36/4-30 36/4-42
437 464 36/4-16 36/3-20 36/3-36 36/3-42 36/4-12 36/3-15 36/4-51 36/5-16 36/4-24 36/4-36
467 497 36/4-14 36/3-18 36/3-30 36/3-36 36/5-15 36/4-21 36/4-42 36/5-12 36/4-20 36/4-30
500 532 36/4-12 36/4-24 36/3-24 36/3-24 36/5-12 36/4-18 36/4-33 36/9-30 36/4-18 36/4-24
535 569 36/4-10 36/4-20 36/3-20 36/3-20 36/5-10 36/4-16 36/4-27 36/9-24 36/4-14 36/4-20
572 609 36/5-12 36/4-16 36/3-16 36/3-18 36/5-9 36/4-12 36/4-24 36/9-20 36/5-18 36/4-18
612 651 36/5-10 36/4-14 36/3-14 36/4-24 36/5-8 36/4-11 36/4-18 36/9-16 36/5-16 36/4-16
655 697 36/5-8 36/4-12 36/4-20 36/4-20 36/5-6 36/4-9 36/4-15 36/9-12 36/5-14 36/5-20
701 746 36/5-7 36/4-10 36/4-16 36/4-18 36/9-12 36/5-12 36/5-21 36/9-10 36/5-12 36/5-16
750 798 36/9-14 36/5-12 36/4-14 36/4-14 36/9-10 36/5-10 36/4-12 36/9-8 36/9-24 36/5-14
802 854 36/9-12 36/5-10 36/4-12 36/4-12 36/9-9 36/5-9 36/5-15 36/9-8 36/9-20 36/5-12
859 914 36/9-10 36/5-8 36/4-10 36/5-16 36/9-8 36/5-7 36/5-12 36/9-6 36/9-16 36/9-24
919 977 36/9-8 36/5-8 36/5-12 36/5-14 36/9-6 36/5-6 36/5-11 36/11-7 36/9-14 36/9-20
983 1046 36/9-7 36/9-16 36/5-10 36/5-12 36/11-7 36/9-12 36/5-9 36/11-6 36/7-8 36/9-16
1052 1119 36/9-6 36/9-12 36/5-8 36/5-10 36/11-6 36/9-10 36/9-18 36/9-10 36/9-14
1126 1197 36/9-5 36/9-10 36/5-8 36/5-8 36/9-4 36/9-8 36/5-6 36/9-8 36/9-12
1204 1281 36/11-6 36/9-8 36/9-14 36/5-7 36/9-3 36/9-7 36/9-12 36/9-7 36/9-10
1379 1467 36/11-4 36/9-6 36/9-10 36/9-12 36/11-3 36/11-7 36/9-9 36/11-6 36/9-7
1579 1679 36/11-3Z 36/11-6 36/9-7 36/9-8 36/11-5 36/9-6 36/11-7
1807 1923 36/11-4 36/9-5 36/9-6 36/11-3 36/11-6
2069 2201 36/11-3 36/9-4 36/11-6 36/11-4

* Please refer to footnotes listed at the end of this section on page 60.

56 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Optimized Diaphragm Shear Tables 1.6


Span = 6'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
207 221 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
222 236 36/3-72 36/3-72 36/3-72 36/3-72 36/3-48 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
237 253 36/3-48 36/3-72 36/3-72 36/3-72 36/3-39 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
254 270 36/3-42 36/3-72 36/3-72 36/3-72 36/3-30 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
272 289 36/3-36 36/3-72 36/3-72 36/3-72 36/3-24 36/3-69 36/4-72 36/4-30 36/4-72 36/4-72
291 309 36/3-30 36/3-72 36/3-72 36/3-72 36/3-21 36/3-54 36/4-72 36/4-24 36/4-60 36/4-72
311 331 36/3-24 36/3-48 36/3-72 36/3-72 36/3-16 36/3-42 36/4-72 36/4-20 36/4-48 36/4-72
333 354 36/3-20 36/3-42 36/3-72 36/3-72 36/3-14 36/3-33 36/4-72 36/4-18 36/4-42 36/4-60
356 379 36/3-16 36/3-36 36/3-72 36/3-72 36/4-18 36/3-29 36/4-72 36/4-16 36/4-36 36/4-48
381 406 36/4-20 36/3-30 36/3-48 36/3-60 36/4-16 36/3-21 36/4-69 36/4-14 36/4-30 36/4-48
408 434 36/4-18 36/3-24 36/3-42 36/3-48 36/4-14 36/3-19 36/4-55 36/4-12 36/4-24 36/4-36
437 464 36/4-14 36/3-20 36/3-36 36/3-36 36/4-12 36/3-18 36/4-45 36/5-14 36/4-20 36/4-30
467 497 36/4-12 36/3-16 36/3-30 36/3-30 36/4-10 36/4-21 36/4-36 36/5-12 36/4-20 36/4-30
500 532 36/5-16 36/3-14 36/3-24 36/3-24 36/5-12 36/4-18 36/4-30 36/9-24 36/4-16 36/4-24
535 569 36/5-14 36/4-18 36/3-20 36/3-20 36/5-10 36/4-15 36/4-24 36/9-20 36/4-14 36/4-20
572 609 36/5-12 36/4-16 36/3-16 36/3-18 36/5-9 36/4-12 36/4-21 36/9-16 36/5-18 36/4-18
612 651 36/5-10 36/4-14 36/4-20 36/4-24 36/5-7 36/4-11 36/4-18 36/9-14 36/5-14 36/4-14
655 697 36/5-8 36/4-12 36/4-18 36/4-20 36/5-6 36/4-9 36/4-16 36/9-12 36/5-12 36/5-18
701 746 36/5-7 36/4-10 36/4-16 36/4-16 36/9-12 36/5-12 36/4-14 36/9-10 36/9-24 36/5-16
750 798 36/9-14 36/5-12 36/4-12 36/4-14 36/9-10 36/5-9 36/4-12 36/9-8 36/9-20 36/5-14
802 854 36/9-10 36/5-10 36/5-16 36/4-12 36/9-8 36/9-18 36/4-9 36/9-7 36/9-18 36/5-12
859 914 36/9-8 36/5-8 36/5-14 36/4-10 36/9-7 36/9-16 36/5-12 36/9-6 36/9-14 36/7-14
919 977 36/9-8 36/5-7 36/5-12 36/5-12 36/9-6 36/9-12 36/5-11 36/11-7 36/9-12 36/9-18
983 1046 36/9-7 36/9-14 36/5-10 36/5-10 36/11-7 36/9-10 36/5-9 36/11-6 36/9-10 36/9-16
1052 1119 36/9-6 36/9-12 36/5-8 36/5-8 36/11-6 36/9-9 36/9-16 36/9-8 36/9-12
1126 1197 36/9-5 36/9-10 36/5-7 36/5-8 36/11-5 36/9-8 36/9-13 36/9-8 36/7-8
1289 1371 36/11-5 36/9-7 36/9-12 36/9-12 36/11-3 36/9-6 36/9-10 36/11-7 36/9-8
1475 1570 36/11-3 36/11-7 36/9-8 36/9-8 36/9-4 36/9-7 36/9-6
1689 1797 36/11-5 36/9-6 36/9-7 36/11-4 36/9-5 36/11-6
1934 2057 36/11-3 36/11-6 36/9-5 36/11-3 36/11-5

* Please refer to footnotes listed at the end of this section on page 60.
Span = 6'-6''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
194 206 36/3-72 36/3-72 36/3-72 36/3-72 36/3-69 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
207 221 36/3-72 36/3-72 36/3-72 36/3-72 36/3-51 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
222 236 36/3-60 36/3-72 36/3-72 36/3-72 36/3-42 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
237 253 36/3-48 36/3-72 36/3-72 36/3-72 36/3-33 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
254 270 36/3-36 36/3-72 36/3-72 36/3-72 36/3-27 36/3-72 36/4-72 36/4-30 36/4-72 36/4-72
272 289 36/3-30 36/3-72 36/3-72 36/3-72 36/3-24 36/3-57 36/4-72 36/4-24 36/4-72 36/4-72
291 309 36/3-24 36/3-60 36/3-72 36/3-72 36/3-18 36/3-48 36/4-72 36/4-24 36/4-60 36/4-72
311 331 36/3-20 36/3-48 36/3-72 36/3-72 36/3-16 36/3-39 36/4-72 36/4-20 36/4-48 36/4-72
333 354 36/3-18 36/3-36 36/3-72 36/3-72 36/4-21 36/3-30 36/4-72 36/4-18 36/4-42 36/4-60
356 379 36/3-16 36/3-30 36/3-60 36/3-60 36/4-18 36/3-27 36/4-72 36/4-16 36/4-30 36/4-48
381 406 36/4-20 36/3-24 36/3-48 36/3-48 36/4-15 36/3-21 36/4-57 36/5-18 36/4-30 36/4-42
408 434 36/4-16 36/3-24 36/3-36 36/3-42 36/4-12 36/3-18 36/4-48 36/5-16 36/4-24 36/4-36
437 464 36/4-14 36/3-20 36/3-30 36/3-36 36/4-11 36/3-15 36/4-39 36/5-14 36/4-20 36/4-30
467 497 36/5-18 36/3-16 36/3-24 36/3-30 36/4-9 36/3-12 36/4-33 36/5-12 36/4-18 36/4-24
500 532 36/5-14 36/4-20 36/3-20 36/3-24 36/5-12 36/4-16 36/4-27 36/9-20 36/4-16 36/4-24
535 569 36/5-12 36/4-18 36/3-18 36/3-20 36/5-9 36/4-15 36/4-24 36/9-18 36/4-14 36/4-20
572 609 36/4-8 36/4-14 36/3-16 36/3-16 36/5-8 36/4-12 36/4-21 36/9-14 36/4-12 36/4-18
612 651 36/5-10 36/5-18 36/4-20 36/3-14 36/5-7 36/5-15 36/4-18 36/9-12 36/5-14 36/4-14
655 697 36/5-8 36/5-16 36/4-18 36/4-18 36/5-6 36/5-12 36/4-15 36/9-10 36/5-12 36/5-18
701 746 36/5-7 36/5-14 36/4-14 36/4-16 36/9-10 36/5-11 36/4-12 36/7-7 36/7-14 36/5-16
750 798 36/9-12 36/5-12 36/5-18 36/4-14 36/9-9 36/5-9 36/5-15 36/9-8 36/9-18 36/5-14
802 854 36/9-10 36/5-10 36/5-16 36/4-12 36/9-8 36/9-16 36/4-9 36/9-7 36/9-16 36/5-12
859 914 36/9-8 36/5-8 36/5-12 36/5-14 36/9-7 36/5-7 36/5-12 36/9-6 36/9-14 36/7-14
919 977 36/9-8 36/5-7 36/5-12 36/5-12 36/9-6 36/5-6 36/5-9 36/11-7 36/9-12 36/7-12
983 1046 36/9-6 36/9-12 36/5-10 36/5-10 36/9-5 36/9-10 36/5-9 36/11-6 36/9-10 36/9-14
1052 1119 36/11-7 36/7-8 36/5-8 36/9-20 36/9-4 36/9-8 36/9-15 36/9-8 36/9-12
1204 1281 36/9-4 36/9-8 36/9-12 36/9-14 36/9-3 36/9-6 36/9-9 36/9-6 36/7-7
1379 1467 36/11-4 36/9-6 36/7-7 36/9-10 36/11-3 36/9-5 36/9-8 36/11-6 36/9-7
1579 1679 36/11-3 36/9-4 36/9-7 36/9-7 36/11-4 36/9-6 36/11-7
1807 1923 36/11-4 36/9-5 36/11-7 36/11-3 36/11-6

* Please refer to footnotes listed at the end of this section on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 57
Steel Deck Fastening Systems

1.6 Optimized Diaphragm Shear Tables


Span = 7'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
194 206 36/3-72 36/3-72 36/3-72 36/3-72 36/3-57 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
207 221 36/3-60 36/3-72 36/3-72 36/3-72 36/3-47 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
222 236 36/3-48 36/3-72 36/3-72 36/3-72 36/3-36 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
237 253 36/3-42 36/3-72 36/3-72 36/3-72 36/3-30 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
254 270 36/3-36 36/3-72 36/3-72 36/3-72 36/3-27 36/3-63 36/4-72 36/4-30 36/4-72 36/4-72
272 289 36/3-30 36/3-60 36/3-72 36/3-72 36/3-21 36/3-51 36/4-72 36/4-24 36/4-60 36/4-72
291 309 36/3-24 36/3-48 36/3-72 36/3-72 36/3-18 36/3-42 36/4-72 36/4-20 36/4-48 36/4-72
311 331 36/3-20 36/3-42 36/3-72 36/3-72 36/3-16 36/3-36 36/4-72 36/4-20 36/4-42 36/4-60
333 354 36/3-18 36/3-36 36/3-60 36/3-72 36/3-12 36/3-30 36/4-72 36/4-16 36/4-36 36/4-48
356 379 36/3-14 36/3-30 36/3-48 36/3-60 36/4-16 36/3-24 36/4-63 36/4-14 36/4-30 36/4-48
381 406 36/4-18 36/3-24 36/3-42 36/3-48 36/4-15 36/3-21 36/4-51 36/5-18 36/4-24 36/4-42
408 434 36/4-16 36/3-20 36/3-36 36/3-36 36/4-12 36/3-18 36/4-42 36/5-14 36/4-24 36/4-36
437 464 36/4-14 36/3-18 36/3-30 36/3-30 36/5-15 36/3-15 36/4-36 36/5-12 36/4-20 36/4-30
467 497 36/4-12 36/3-16 36/3-24 36/3-24 36/5-12 36/4-18 36/4-30 36/9-24 36/4-18 36/4-24
500 532 36/5-14 36/4-20 36/3-20 36/3-24 36/5-11 36/4-16 36/4-27 36/9-20 36/4-16 36/4-20
535 569 36/5-12 36/4-16 36/3-18 36/3-20 36/5-10 36/4-14 36/4-21 36/9-16 36/4-14 36/4-20
572 609 36/5-10 36/4-14 36/3-14 36/3-16 36/5-8 36/4-12 36/4-20 36/9-14 36/4-12 36/4-16
612 651 36/9-18 36/4-12 36/4-20 36/3-14 36/5-7 36/5-14 36/4-17 36/9-12 36/5-14 36/4-14
655 697 36/5-8 36/5-14 36/4-16 36/4-18 36/5-6 36/5-12 36/4-15 36/9-10 36/5-12 36/5-18
701 746 36/5-7 36/5-12 36/4-14 36/4-16 36/9-10 36/5-11 36/5-18 36/7-7 36/9-20 36/5-14
750 798 36/5-6 36/4-8 36/4-12 36/4-14 36/9-9 36/5-9 36/5-15 36/9-8 36/9-18 36/5-12
802 854 36/9-10 36/5-10 36/5-14 36/4-12 36/9-7 36/9-16 36/5-12 36/9-7 36/9-14 36/7-14
859 914 36/9-8 36/5-8 36/5-12 36/5-14 36/9-6 36/9-12 36/5-11 36/9-6 36/9-12 36/9-18
919 977 36/9-7 36/9-14 36/5-10 36/5-12 36/9-6 36/9-10 36/5-10 36/11-6 36/9-10 36/7-12
983 1046 36/9-6 36/9-12 36/5-10 36/5-10 36/11-6 36/9-10 36/9-15 36/7-7 36/9-14
1052 1119 36/11-7 36/9-10 36/5-8 36/9-18 36/7-3 36/7-6 36/9-12 36/9-8 36/9-12
1204 1281 36/11-5 36/9-8 36/9-12 36/9-12 36/9-3 36/9-6 36/9-9 36/11-8 36/7-7
1379 1467 36/11-4 36/9-6 36/9-8 36/9-10 36/11-3 36/11-6 36/9-8 36/11-6 36/9-7
1579 1679 36/11-5 36/9-6 36/9-7 36/11-4 36/9-6 36/11-6
1807 1923 36/11-4 36/9-5 36/11-7 36/11-3 36/9-4

* Please refer to footnotes listed at the end of this section on page 60.
Span = 7'-6''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
181 193 36/3-72 36/3-72 36/3-72 36/3-72 36/3-63 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
194 206 36/3-72 36/3-72 36/3-72 36/3-72 36/3-51 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
207 221 36/3-60 36/3-72 36/3-72 36/3-72 36/3-42 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
222 236 36/3-48 36/3-72 36/3-72 36/3-72 36/3-36 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
237 253 36/3-36 36/3-72 36/3-72 36/3-72 36/3-30 36/3-69 36/4-72 36/4-30 36/4-72 36/4-72
254 270 36/3-30 36/3-72 36/3-72 36/3-72 36/3-24 36/3-57 36/4-72 36/4-30 36/4-60 36/4-72
272 289 36/3-24 36/3-60 36/3-72 36/3-72 36/3-21 36/3-45 36/4-72 36/4-24 36/4-48 36/4-72
291 309 36/3-24 36/3-48 36/3-72 36/3-72 36/3-18 36/3-39 36/4-72 36/4-20 36/4-48 36/4-72
311 331 36/3-20 36/3-42 36/3-72 36/3-72 36/3-15 36/3-33 36/4-72 36/4-18 36/4-42 36/4-60
333 354 36/3-18 36/3-36 36/3-60 36/3-60 36/4-18 36/3-27 36/4-66 36/4-16 36/4-36 36/4-48
356 379 36/3-14 36/3-30 36/3-48 36/3-48 36/4-16 36/3-24 36/4-54 36/5-20 36/4-30 36/4-42
381 406 36/4-18 36/3-24 36/3-42 36/3-42 36/4-14 36/3-18 36/4-48 36/5-16 36/4-24 36/4-36
408 434 36/4-16 36/3-20 36/3-30 36/3-36 36/5-16 36/3-15 36/4-39 36/5-14 36/4-20 36/4-30
437 464 36/4-14 36/3-18 36/3-30 36/3-30 36/5-14 36/4-21 36/4-33 36/5-12 36/4-20 36/4-30
467 497 36/5-16 36/3-14 36/3-24 36/3-24 36/5-12 36/4-18 36/4-30 36/7-14 36/4-18 36/4-24
500 532 36/5-14 36/4-18 36/3-20 36/3-20 36/5-10 36/4-16 36/4-24 36/9-18 36/5-20 36/4-20
535 569 36/5-12 36/4-16 36/3-18 36/3-20 36/5-9 36/4-14 36/4-21 36/9-16 36/5-18 36/4-20
572 609 36/5-10 36/4-14 36/3-14 36/3-16 36/5-8 36/5-16 36/4-18 36/9-12 36/5-16 36/4-16
612 651 36/5-8 36/5-16 36/4-18 36/4-20 36/5-7 36/5-14 36/5-22 36/9-12 36/5-12 36/5-20
655 697 36/5-8 36/5-14 36/4-16 36/4-18 36/9-12 36/5-12 36/5-20 36/9-10 36/5-12 36/5-16
701 746 36/5-7 36/5-12 36/4-14 36/5-20 36/9-10 36/5-10 36/4-12 36/9-8 36/9-18 36/5-14
750 798 36/5-6 36/5-10 36/5-16 36/5-18 36/7-6 36/5-9 36/5-15 36/9-7 36/9-16 36/5-12
802 854 36/7-7 36/9-18 36/5-14 36/5-16 36/9-7 36/9-15 36/5-12 36/11-8 36/9-14 36/7-14
859 914 36/9-8 36/5-8 36/5-12 36/5-14 36/9-6 36/9-12 36/5-11 36/9-6 36/9-12 36/9-18
919 977 36/9-7 36/5-7 36/5-10 36/5-12 36/11-7 36/9-10 36/5-9 36/11-6 36/9-10 36/9-14
983 1046 36/9-6 36/5-6 36/9-18 36/5-10 36/9-5 36/7-7 36/9-15 36/7-7 36/7-10
1126 1197 36/11-6 36/9-8 36/5-7 36/9-14 36/9-3 36/9-7 36/5-6 36/9-7 36/9-10
1289 1371 36/11-8 36/9-10 36/7-8 36/7-4 36/9-9 36/11-6 36/9-7
1475 1570 36/9-5 36/9-7 36/9-8 36/9-4 36/9-6 36/11-7
1689 1797 36/11-7 36/9-6 36/9-5

* Please refer to footnotes listed at the end of this section on page 60.

58 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

Optimized Diaphragm Shear Tables 1.6


Span = 8'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
181 193 36/3-72 36/3-72 36/3-72 36/3-72 36/3-54 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
194 206 36/3-60 36/3-72 36/3-72 36/3-72 36/3-48 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
207 221 36/3-48 36/3-72 36/3-72 36/3-72 36/3-39 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
222 236 36/3-42 36/3-72 36/3-72 36/3-72 36/3-33 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
237 253 36/3-36 36/3-72 36/3-72 36/3-72 36/3-27 36/3-63 36/4-72 36/4-30 36/4-72 36/4-72
254 270 36/3-30 36/3-60 36/3-72 36/3-72 36/3-24 36/3-51 36/4-72 36/4-24 36/4-60 36/4-72
272 289 36/3-24 36/3-48 36/3-72 36/3-72 36/3-21 36/3-45 36/4-72 36/4-24 36/4-48 36/4-72
291 309 36/3-20 36/3-42 36/3-72 36/3-72 36/3-18 36/3-36 36/4-72 36/4-20 36/4-42 36/4-60
311 331 36/3-20 36/3-36 36/3-60 36/3-72 36/3-15 36/3-30 36/4-69 36/4-18 36/4-36 36/4-48
333 354 36/3-16 36/3-30 36/3-48 36/3-60 36/4-18 36/3-27 36/4-60 36/4-16 36/4-30 36/4-48
356 379 36/4-20 36/3-24 36/3-42 36/3-48 36/4-16 36/3-21 36/4-51 36/4-14 36/4-30 36/4-42
381 406 36/4-16 36/3-24 36/3-36 36/3-42 36/4-14 36/3-18 36/4-42 36/5-16 36/4-24 36/4-36
408 434 36/5-20 36/3-20 36/3-30 36/3-36 36/4-12 36/3-15 36/4-36 36/5-14 36/4-20 36/4-30
437 464 36/5-16 36/3-18 36/3-24 36/3-30 36/5-14 36/4-20 36/4-33 36/5-12 36/4-20 36/4-24
467 497 36/5-14 36/4-20 36/3-24 36/3-24 36/5-12 36/4-18 36/4-27 36/9-20 36/4-16 36/4-24
500 532 36/4-10 36/4-18 36/3-20 36/3-20 36/5-10 36/4-15 36/4-24 36/7-12 36/5-20 36/4-20
535 569 36/5-12 36/4-16 36/4-24 36/3-18 36/5-9 36/4-13 36/4-21 36/9-14 36/5-16 36/4-18
572 609 36/5-10 36/4-14 36/4-20 36/3-16 36/5-8 36/4-12 36/4-18 36/9-12 36/5-14 36/4-16
612 651 36/5-8 36/5-16 36/4-18 36/4-20 36/5-7 36/4-10 36/4-15 36/9-10 36/5-12 36/4-14
655 697 36/5-8 36/5-14 36/4-16 36/4-16 36/5-6 36/5-12 36/4-14 36/9-10 36/7-14 36/5-16
701 746 36/9-12 36/5-12 36/4-14 36/5-20 36/7-7 36/5-10 36/4-12 36/9-8 36/9-18 36/5-14
750 798 36/9-10 36/5-10 36/5-16 36/5-16 36/7-6 36/5-9 36/5-14 36/9-7 36/9-14 36/5-12
802 854 36/7-7 36/5-8 36/5-14 36/5-14 36/9-7 36/9-14 36/5-12 36/11-8 36/7-10 36/7-14
859 914 36/9-8 36/5-8 36/5-12 36/4-10 36/9-6 36/9-12 36/5-11 36/11-7 36/9-12 36/7-12
919 977 36/9-7 36/5-7 36/5-10 36/5-10 36/9-5 36/9-10 36/5-9 36/11-6 36/9-10 36/9-14
983 1046 36/9-6 36/7-8 36/5-8 36/5-10 36/11-6 36/7-7 36/5-8 36/7-7 36/7-10
1126 1197 36/11-5 36/9-8 36/5-7 36/7-10 36/9-7 36/5-6 36/9-7 36/9-10
1289 1371 36/9-6 36/7-7 36/7-8 36/9-5 36/9-8 36/11-6 36/9-7
1475 1570 36/9-7 36/9-8 36/9-6 36/11-7
1689 1797 36/9-5 36/9-6 36/9-5

* Please refer to footnotes listed at the end of this section on page 60.

Span = 9'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
169 180 36/3-72 36/3-72 36/3-72 36/3-72 36/3-57 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
181 193 36/3-60 36/3-72 36/3-72 36/3-72 36/3-48 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
194 206 36/3-48 36/3-72 36/3-72 36/3-72 36/3-42 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
207 221 36/3-42 36/3-72 36/3-72 36/3-72 36/3-36 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
222 236 36/3-36 36/3-72 36/3-72 36/3-72 36/3-30 36/3-63 36/4-72 36/4-30 36/4-60 36/4-72
237 253 36/3-30 36/3-60 36/3-72 36/3-72 36/3-24 36/3-54 36/4-72 36/4-30 36/4-60 36/4-72
254 270 36/3-30 36/3-48 36/3-72 36/3-72 36/3-21 36/3-45 36/4-72 36/4-24 36/4-48 36/4-72
272 289 36/3-24 36/3-48 36/3-72 36/3-72 36/3-20 36/3-39 36/4-72 36/4-20 36/4-42 36/4-60
291 309 36/3-20 36/3-42 36/3-60 36/3-72 36/3-16 36/3-33 36/4-69 36/4-20 36/4-36 36/4-60
311 331 36/3-18 36/3-36 36/3-48 36/3-60 36/3-14 36/3-27 36/4-57 36/4-18 36/4-36 36/4-48
333 354 36/3-16 36/3-30 36/3-48 36/3-48 36/3-12 36/3-24 36/4-51 36/4-16 36/4-30 36/4-42
356 379 36/4-18 36/3-24 36/3-36 36/3-42 36/4-15 36/3-21 36/4-45 36/4-14 36/4-24 36/4-36
381 406 36/4-16 36/3-20 36/3-36 36/3-36 36/4-12 36/3-18 36/4-39 36/4-12 36/4-24 36/4-30
408 434 36/4-14 36/3-20 36/3-30 36/3-30 36/5-15 36/3-15 36/4-33 36/5-14 36/4-20 36/4-30
437 464 36/5-16 36/3-16 36/3-24 36/3-24 36/5-12 36/4-18 36/4-30 36/5-12 36/4-18 36/4-24
467 497 36/5-14 36/4-20 36/3-20 36/3-24 36/4-9 36/4-16 36/4-24 36/9-18 36/4-16 36/4-24
500 532 36/4-10 36/4-16 36/3-18 36/3-20 36/5-10 36/4-15 36/4-21 36/9-14 36/4-14 36/4-20
535 569 36/5-10 36/4-14 36/3-16 36/3-18 36/5-9 36/4-12 36/4-20 36/7-10 36/5-16 36/4-18
572 609 36/5-10 36/5-16 36/4-20 36/4-20 36/5-8 36/5-14 36/4-18 36/9-12 36/5-14 36/4-16
612 651 36/5-8 36/4-12 36/4-16 36/4-18 36/5-7 36/5-12 36/4-15 36/9-10 36/5-12 36/4-14
655 697 36/9-12 36/4-10 36/4-14 36/4-16 36/5-6 36/5-11 36/4-14 36/9-8 36/9-18 36/5-16
701 746 36/9-10 36/5-12 36/5-16 36/4-14 36/9-9 36/5-9 36/4-12 36/9-8 36/9-16 36/5-14
750 798 36/7-7 36/5-10 36/4-12 36/5-16 36/9-7 36/5-8 36/5-14 36/9-7 36/9-14 36/5-12
802 854 36/9-8 36/5-8 36/4-10 36/5-14 36/9-7 36/5-7 36/5-12 36/9-6 36/9-12 36/7-14
859 914 36/9-7 36/5-8 36/5-12 36/5-12 36/9-6 36/5-6 36/5-10 36/11-6 36/9-10 36/9-16
919 977 36/5-7 36/5-10 36/5-10 36/9-10 36/5-9 36/9-8 36/9-14
1052 1119 36/7-7 36/5-8 36/5-8 36/7-6 36/9-12 36/9-7 36/9-10
1204 1281 36/9-10 36/9-10 36/9-9 36/9-8
1379 1467 36/9-8 36/7-7 36/9-7 36/11-8
1579 1679 36/9-6 36/11-8 36/9-5 36/11-6

* Please refer to footnotes listed at the end of this section on page 60.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 59
Steel Deck Fastening Systems

1.6 Optimized Diaphragm Shear Tables


Span = 10'-0''
Allowable Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)*
diaphragm design
strength, plf* X-ENP-19 with tf 1/4" X-HSN 24 with 3/16" tf 3/8" X-HSN 24 with 1/8" tf < 3/16"
SASD SASD
22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga.
(seismic) (wind)
138 147 36/3-72 36/3-72 36/3-120 36/3-120 36/3-72 36/3-72 36/4-72 36/4-72 36/4-72 36/4-72
148 157 36/3-72 36/3-72 36/3-72 36/3-72 36/3-66 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
158 168 36/3-72 36/3-72 36/3-72 36/3-72 36/3-57 36/3-72 36/4-72 36/4-60 36/4-72 36/4-72
169 180 36/3-60 36/3-72 36/3-72 36/3-72 36/3-51 36/3-72 36/4-72 36/4-48 36/4-72 36/4-72
181 193 36/3-48 36/3-72 36/3-72 36/3-72 36/3-42 36/3-72 36/4-72 36/4-42 36/4-72 36/4-72
194 206 36/3-48 36/3-72 36/3-72 36/3-72 36/3-36 36/3-72 36/4-72 36/4-36 36/4-72 36/4-72
207 221 36/3-42 36/3-72 36/3-72 36/3-72 36/3-33 36/3-63 36/4-72 36/4-36 36/4-72 36/4-72
222 236 36/3-36 36/3-60 36/3-72 36/3-72 36/3-27 36/3-57 36/4-72 36/4-30 36/4-60 36/4-72
237 253 36/3-30 36/3-48 36/3-72 36/3-72 36/3-24 36/3-48 36/4-72 36/4-24 36/4-48 36/4-72
254 270 36/3-24 36/3-48 36/3-72 36/3-72 36/3-21 36/3-42 36/4-72 36/4-24 36/4-48 36/4-60
272 289 36/3-24 36/3-42 36/3-60 36/3-72 36/3-18 36/3-36 36/4-69 36/4-20 36/4-42 36/4-60
291 309 36/3-20 36/3-36 36/3-48 36/3-60 36/3-16 36/3-30 36/4-60 36/4-18 36/4-36 36/4-48
311 331 36/3-18 36/3-30 36/3-48 36/3-48 36/3-14 36/3-27 36/4-51 36/4-16 36/4-30 36/4-48
333 354 36/3-16 36/3-24 36/3-42 36/3-48 36/3-12 36/3-24 36/4-45 36/4-14 36/4-30 36/4-42
356 379 36/4-18 36/3-24 36/3-36 36/3-42 36/4-14 36/3-21 36/4-39 36/5-16 36/4-24 36/4-36
381 406 36/4-16 36/3-20 36/3-30 36/3-36 36/4-12 36/3-18 36/4-36 36/4-12 36/4-20 36/4-30
408 434 36/4-14 36/3-18 36/3-24 36/3-30 36/5-14 36/4-21 36/4-30 36/5-12 36/4-20 36/4-30
437 464 36/4-12 36/3-16 36/3-24 36/3-24 36/4-10 36/4-18 36/4-27 36/9-18 36/4-18 36/4-24
467 497 36/4-10 36/4-18 36/3-20 36/3-24 36/5-11 36/4-16 36/4-24 36/9-16 36/4-16 36/4-20
500 532 36/5-12 36/4-16 36/3-18 36/3-20 36/5-10 36/4-14 36/4-21 36/9-14 36/4-14 36/4-20
535 569 36/5-10 36/4-14 36/3-16 36/3-16 36/5-8 36/4-12 36/4-18 36/7-10 36/5-16 36/4-18
572 609 36/9-14 36/5-16 36/4-18 36/4-20 36/5-7 36/5-14 36/4-17 36/9-10 36/5-14 36/4-16
612 651 36/5-8 36/5-14 36/4-16 36/4-18 36/5-6 36/5-12 36/4-15 36/9-10 36/5-12 36/5-18
655 697 36/5-7 36/4-10 36/4-14 36/4-16 36/9-9 36/5-11 36/4-13 36/9-8 36/9-16 36/5-16
701 746 36/9-10 36/5-10 36/5-16 36/4-14 36/7-6 36/5-9 36/4-12 36/9-7 36/9-14 36/5-14
750 798 36/5-10 36/5-14 36/5-16 36/7-10 36/5-12 36/7-10 36/5-12
859 914 36/9-12 36/5-10 36/5-12 36/5-6 36/5-9 36/9-10 36/7-12
983 1046 36/9-14 36/9-14 36/5-8 36/9-12
1126 1197 36/9-10 36/9-12 36/9-10 36/9-8
1289 1371 36/7-7 36/7-7 36/9-7 36/9-7
*Please refer to footnotes listed below.

1 SASD (seismic) values calculated by using a safety factor () of 2.50 for seismic loads. For SLRFD (seismic), multiply SASD (seismic) by 2.50 and then by a resistance factor ()
of 0.65. For SLSD (seismic), multiply SASD (seismic) by 2.50 and then by a resistance factor () of 0.60. Diaphragm shear stiffness should be calculated separately per
Section 1.1.8.
2 SASD (wind) values calculated by using a safety factor () of 2.35 for seismic loads. For SLRFD (wind), multiply SASD (wind) by 2.35 and then by a resistance factor () of
0.70. For SLSD (wind), multiply SASD (wind) by 2.35 and then by a resistance factor () of 0.65. Diaphragm shear stiffness should be calculated separately per
Section 1.1.8.
3 Tabulated fastening patterns apply to standard (Fy 33 ksi; Fu 45 ksi) or high strength (Fy 80 ksi; Fu 92 ksi) 1-1/2" deep, 6" center-to-center types B and BI
steel deck. Panel buckling has been checked.
4 At diaphragm perimeter, Hilti powder-actuated frame fasteners should be spaced at identical spacing as sidelap connectors.
5 Interpolation of diaphragm shear strength values is allowed between span dimensions, sidelap spacings and deck gauge. Alternatively, use calculations as
discussed in Section 1.1.8 to determine diaphragm shear capacities directly.
6 To convert from sidelap spacing (SS) to sidelaps per span (SPS), use the following formula: SPS=((span,ft) x 12)/(SS, in.). Round up to the next whole
sidelap connector.
7 For 16 gauge steel deck or for high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH. For more information on Hilti Sidelap Connectors
refer to Section 1.5.
8 For diaphragm shear load values using Hilti #10 HWH screws, use the Hilti Profis DF Diaphragm software or contact Hilti at 877-749-6337 or deck@hilti.com.
9 Additional diaphragm fastening patterns and optimized attachment options can be developed from Hilti Profis DF Diaphragm Software. Contact Hilti Technical
Services or find more information at www.us.hilti.com/decking (USA) or www.hilti.ca/decking (Canada).
10 For 36/9 or 36/11 patterns, please see footnote 2 of Table 10 (page 19).

60 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

X-HVB Shear Connector 1.7

1.7.1 Product Description 1.7.1 Product Description

1.7.2 Material Specifications


The Hilti X-HVB Shear Connector is a Guide specification
1.7.3 Technical Data
mechanically attached shear transfer
Shear connector: Shear connectors
device for use in composite beam 1.7.4 Connector Positioning
shall be one piece formed steel with zinc
construction with steel beams and 1.7.5 Ordering Information
plating in accordance with ASTM B633
concrete slabs as an alternate to
SC 1 Type III. Connectors shall be Hilti
welded studs.
X-HVB as supplied by Hilti Inc.
Product features
Installation: Shear connectors shall
Ductile connections be installed using Hilti X-ENP-21 HVB
Minimal damage to coatings powder-actuated fasteners in
Fast and simple installation accordance with manufacturers
Install in virtually any weather recommendation. (Note: Do not
No electrical power source required use X-ENP-19 L15.)

1.7.2 Material Specification


X-HVB: Carbon Steel with Fu = 39,000 psi
Zinc plated for corrosion resistance in accordance with ASTM B633, SC 1,
Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical
Guide Volume 1: Direct Fastening for more information.

1.7.3 Technical Data

Product selection and performance in concrete over metal deck composite floor slabs3
Connector Minimum slab Maximum rib height, hr Nominal Allowable
X-HVB
height, Hs thickness, Ycon in. (mm) shear strength1, Qn shear strength2, q
connector
in. (mm) in. (mm) wr /hr 1.8 wr /hr < 1.8 lb (kN) lb (kN)
3-1/8 3-11/16 1-3/4 1-3/4 6294 3147
X-HVB80
(80) (93) (45) (45) (28.0) (14.0)
3-3/4 4-1/4 2-3/8 2-1/4
X-HVB95
(95) (108) (60) (57)
4-5/16 4-13/16 2-15/16 2-5/8
X-HVB110
(110) (123) (75) (66) 7868 3934
4-15/16 5-7/16 3-1/8 2-15/16 (35.0) (17.5)
X-HVB125
(125) (138) (80) (75)
5-1/2 6 3-1/8 3-1/8
X-HVB140
(140) (152) (80) (80)
1 Nominal shear strength to be used for designs per AISC-LRFD and unfactored shear resistance per AISC design formulas.
2 Allowable shear strength to be used for designs per AISC-ASD.
3 Tabulated load values based upon installation in base steel greater than or equal to 5/16".

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 61
Steel Deck Fastening Systems

1.7 X-HVB Shear Connector


Strength reduction factors for concrete over metal deck composite floor slabs

Ribs perpendicular to the beam Ribs parallel to the beam

Number of X-HVB's Condition Rg


Rg
in One Rib
1 1.00 wr
1.5 1.00
2 0.85 hr
3 0.70 wr
< 1.5 0.851
hr
1 For a single shear connector.

Connector placement along the beams Deflections

The ductile performance of the Hilti X-HVB Shear Connector Beam deflections are computed by conventional elastic
allows distribution of the calculated required number of formulas. For beams with partial shear connection, deflections
X-HVBs uniformly between the points of zero and maximum may be estimated by using the following formula for the
moment. effective moment of inertia:

Point loads I eff = Is + n x ( l t r ls )


l s = moment of inertia of steel section
Application of large point loads causes abrupt changes in
n = connection fraction
shear. To avoid excessive slip, additional X-HVB connectors
l tr = moment of inertia with 100% connection
may be necessary between the point load and the support.
Continuous beams
Partial shear connection
Hilti X-HVB Shear Connectors are also suitable for use in
AISC-LRFD and AISC-ASD both require that the capacity
continuous composite beams. The connectors are distributed
of the installed shear connectors must be no less than 25%
uniformly between the point of zero moment and the point of
of the calculated shear load for full composite design. This
maximum moment.
requirement is applicable, independent of whether welded
studs or X-HVBs are used for the shear connection.

To obtain access to Hiltis BDES Composite Design Software, which designs and analyzes composite and
non-composite beams using Hilti X-HVB Shear Connectors under distributed and point loads in accordance
with AISC LRFD, contact Hilti Technical Support at 1-877-749-6337.

62 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Steel Deck Fastening Systems

X-HVB Shear Connector 1.7

1.7.4 Connector Positioning


Connector positioning (metal decking ribs transverse to beam)

1. One to three X-HVBs per rib. 2. X-HVBs transverse or parallel to beam.

= = 40
1-9/16" 40
1-9/16" = =

Wr 1-9/16" Wr 1-9/16"

3. With one X-HVB per rib, the leg may be either centered in 4. With two or three X-HVBs per rib, the legs may be either
the rib or positioned to give a 1-9/16" (40 mm) clearance to centered in the rib or alternated about the center.
the side of the rib.
2"
50 50
2" 5b. S
 pacings along the ribs (other
100
4" 100
4" decking profiles)

Minimum spacing 2" (50 mm),


however for decking profiles with:
>> 4"
2" 51
100
wr /m < 0.7 and wr /hr < 1.8, the
minimum spacing is increased from
2" to 4" (50 to 100 mm).

5a. Spacing along the ribs (2" and 3" m = spacing of ribs 6. If the decking has a stiffener in the rib
U.S. composite floor deck profiles) bottom, position the X-HVBs against
the stiffener.

Connector positioning (ribs parallel to beam and solid slabs)


4Y
4d or 24"
conor 600
2"
50 X-HVBs may be placed with zero
100
4" clearance to edge of flange.
Ycon
d

1.7.5 Ordering Information

X-HVB Shear Connectors* Setting Equipment for X-HVB


Description Qty/Pkg Shear Connectors
Description
X-HVB80 250
X-HVB95 250 DX-76
X-HVB110 250 X-76-F-HVB Baseplate
X-HVB125 200 X-76-P-HVB Piston
X-76-PS Stop Ring
* X-HVB shear connectors must be fastened with the X-76-F-HVB fastener guide, the
X-76-P-HVB piston and the X-ENP-21 HVB fastener.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 63
PTG Decking Supplement 2013

Notes

64 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Direct Fastening Technical Guide 2014
Steel Deck Fastening Systems

BAR JOIST FASTENING SYSTEMS

DX 860-HSN
Powder actuated tool with a high fastening rate which can help significantly
reduce the time it takes to attach deck
No touch-up work required perfect for fastening painted or galvanized deck
surfaces
Magazine for 40 continuous fastenings up to 1000 fastenings per hour
Unique piston/brake system helps prevent the fastener from punching through
the deck
Fastenings can be made even on very thin supporting structures without the
need for weld washers

DX 460-SM
Fully automated hand-held tool for miscellaneous fastenings on steel thicknesses
of 3/16" and thicker, such as profile metal sheets on bar joists.

STRUCTURAL STEEL FASTENING SYSTEMS

DX 860-ENP-L
Fully automatic tool fastens up to 1000 fastenings per hour
40-cartridge and 40-fastener capacity minimizes loading time and increases
productivity
Built-in, adjustable power regulator for optimal control in achieving reliable
fastenings
Cartridge and fastener magazine can be loaded from the top without having to
bend over
Use On Demand program to meet your project needs
DX 76
Power regulator for optimal control to achieve reliable fastenings across a broad
application range
Magazine fasteners and boosters help increase operating speed and reduce the
number of wasted fasteners
Fastener guide options allow for customizing the tool to the job

DECK SIDELAPS FASTENING SYSTEMS

ST 1800 and SDT 5


SDT 5 magazine holds 50 collated sidelap connectors for deck sidelap
applications where productivity is essential
Two handle design and low vibration grip provide greater operator comfort and
less fatigue
A range of fasteners for sidelaps and for deck to thin bar joist
Adjustable torque control for improved sidelap connector performance
Heavy duty design helps ensure longer tool life
Rotatable nosepiece of SDT 5 allows for easy access into most deck profiles
from a variety of positions
Electronically controlled, variable speed screwdriver with claw clutch for easier
fastener starts
Quick and easy jam release mechanism

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014
Hilti. Outperform. Outlast.
P.O. Box 21148, Tulsa, OK 74121 Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com Servicio al Cliente en espaol
1-800-879-5000 Hilti (Canada) Corporation 1-800-363-4458 www.hilti.ca Hilti is an equal opportunity employer
Hilti is a registered trademark of Hilti, Corp. Copyright 2014 by Hilti, Inc. H268 3445389 10/14 BB
The data contained in this literature was current as of the date of publication. Updates and changes may be made based on later testing. If verification is needed that the
data is still current, please contact the Hilti Technical Support Specialists at 1-800-879-8000. All published load values contained in this literature represent the results
of testing by Hilti or test organizations. Local base materials were used. Because of variations in materials, on-site testing is necessary to determine performance at any *ISO 14001 US Only
specific site. Laser beams represented by red lines in this publication. Printed in the United States