NYY 11xx(1.5-800)
(1.5-800) mm
mm 0.6/1
0.6/1 kV kV
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI IEC 60502-1 : 2009
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations, Copper Conductor
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is PVC Insulation
mm mm kg/km unlikely.
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30 C * Short
circuit current
Nom. DC AC Trefoil Flat
at
Cross Resistance Resistance formation formation in air in ground in air in ground 1 sec
Sect. at 20C at 70C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYY
NYY 22xx(1.5-300)
(1.5-300) mm
mm 2
2
0.6/1
0.6/1 kV kV
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI IEC 60502-1 : 2009
Construction Data
Application :
Nom. Overall Cable Copper Conductor
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations,
Section industry and switchgear as well as for urban
PVC Insulation
Area approx. approx. supply networks, if mechanical damage is
mm mm kg/km unlikely. PVC Inner Sheath
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30C * at
Cross Resistance Resistance 1 sec
Sect. at 20C at 70C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYY
NYY 33xx(1.5-300)
(1.5-300) mm
mm 0.6/1
0.6/1 kV kV
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI IEC 60502-1 : 2009
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors Copper Conductor
Cross Diameter Weight and burried in the ground, for power stations,
Section industry and switchgear as well as for urban
Area approx. approx. PVC Insulation
supply networks, if mechanical damage is
mm mm kg/km unlikely.
PVC Inner Sheath
1.5 13.0 224 Special Features on Request :
Tinned Coated Copper Conductor
2.5 14.0 277 PVC Sheath
Fire Resistance
4 16.1 383 Oil Resistance
UV Resistance
6 17.3 471
Flame Retardant Cat. A, B, C
10 19.4 649 Flame Retardant Non Category
Heat Resistance
16 22.0 875
Anti Termite
25 25.0 1,248 Anti Rodent
Low Smoke Zero Halogen
35 27.5 1,606
Nylon Coated
50 30.0 1,857
Note :
70 34.0 2,556
Conductor Shape
95 38.5 3,428 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
120 41.5 4,152
25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
150 46.0 5,115 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
185 50.5 6,330
Tinned Coated Copper Conductor
240 57.0 8,215 Electrical properties for tinned coated copper conductor will be submitted upon request
300 62.5 10,116
Standard Packing
1.5 - 95 sqmm supplied in wooden drum @ 1000 m
120 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC at
at 30C *
Cross Resistance Resistance 1 sec
Sect. at 20C at 70C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYY
NYY 44xx(1.5-300)
(1.5-300) mm
mm 0.6/1
0.6/1 kV kV
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI IEC 60502-1 : 2009
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors Copper Conductor
Cross Diameter Weight and burried in the ground, for power stations,
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is
PVC Insulation
mm mm kg/km unlikely.
PVC Inner Sheath
1.5 13.8 259 Special Features on Request :
Tinned Coated Copper Conductor
2.5 15.0 324 PVC Sheath
Fire Resistance
4 17.3 453 Oil Resistance
UV Resistance
6 18.7 563
Flame Retardant Cat. A, B, C
10 21.5 794 Flame Retardant Non Category
Heat Resistance
16 23.5 1,083
Anti Termite
25 27.5 1,558 Anti Rodent
Low Smoke Zero Halogen
35 30.0 2,018
Nylon Coated
50 35.5 2,466
70 39.0 3,334 Note :
95 44.5 4,491 Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
120 48.5 5,504 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
150 54.5 6,787 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
185 59.0 8,392
240 66.0 10,818 Tinned Coated Copper Conductor
Electrical properties for tinned coated copper conductor will be submitted upon request
300 72.5 13,326
Standard Packing
1.5 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC at
at 30C *
Cross Resistance Resistance 1 sec
Sect. at 20C at 70C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYY
NYY 55xx(1.5-50)
(1.5-50) mm
mm 0.6/1
0.6/1 kV kV
Cu / PVC / PVC
(Copper Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SNI IEC 60502-1 : 2009
Construction Data
Application :
Nom. Overall Cable PVC Filler
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations, Copper Conductor
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is PVC Insulation
mm mm kg/km unlikely.
PVC Inner Sheath
1.5 14.8 302 Special Features on Request :
Tinned Coated Copper Conductor
2.5 16.0 382 Fire Resistance PVC Sheath
Standard Packing
1.5 - 50 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC at
at 30C *
Cross Resistance Resistance 1 sec
Sect. at 20C at 70C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification