0. Abstract
The Ver.B cabinet and internal parts will be in the end of marketing (EOM). The BTS3900 Ver.D cabinet will
be sold to replace the Ver.B cabinet. This PCN is intended for customers using Huawei BTS3900 Ver.B cabinet.
The last date for purchase of the Ver.B cabinet is June 30, 2013 and the last date for supply of Ver.B cabinet
is December 31, 2013.
1. Supplier Information
2. Basic Information
Change Category B
Official release of
Release July 15, 2012
the PCN
No order accepted
End of Marketing June 30, 2013
for Ver.B cabinet
Confidential Page 1 of 10
Product Change Notice
No delivery after December 31, 2013, from which no old cabinets will
End of
EOP for Ver.B be delivered (the delivery time in new sales contracts
Production
cabinet should not be later than this date)
No service
End of Service Subject to the specific contract
provided after EOS
4. Correlated Change
N/A
New BOM Board Name Old BOM Board Name Complete Replacement
Code Code
DC type
Confidential Page 2 of 10
Product Change Notice
New BOM Board Name Old BOM Board Name Complete Replacement
Code Code
Note 1The spare parts of the Ver.D cabinet are different from the Ver.B cabinet. Therefore, a certain
quantity of spare parts of the Ver.B cabinet must be reserved for future use. The last order date of spare parts
is June 30, 2015 for Ver.B cabinet.
6. Categorization Basis
(1) Ver.B cabinet and parts will be in the EOM and be replaced by Ver.D.
(2) The new release improves the capacity of heat dissipation, power supply and distribution. The new
release has all the functions of current version and better performance, such as supporting RFU(2*80W)
modules and one DCDU for RRU inside DC input cabinet.
7. Change Description
The changed parts include the cabinet mechanical part, fan tray, DCDU and power system.etc. The
external size is the same as old one.
The Ver.D cabinet improves the capacity of heat dissipation and power distribution. It has all the
functions of the Ver.B cabinet and better performance instead.
The cabinet version info can be acquired by OMC remotely or be seen on the nameplate in the
cabinet on site.
Confidential Page 3 of 10
Product Change Notice
(A) The size of handle is improved with more space for internal airflow and good UCD performance
still. Air-panel is added inside of cabinet.
(B) The cabinet is improved with no plinth as default. The cabinet can be installed directly to the
concrete ground like BTS3900L. There is 40mm height difference when the Ver.D cabinet without
plinth is installed beside the Ver.B cabinet with plinth.
Confidential Page 4 of 10
Product Change Notice
(C) One DCDU for RRU can be installed into the spare space of BTS3900 DC Ver.D with the internal
cabling space improvement.
(D) The lock is changed for quick open. But the key is the same as the Ver.B.
(E) The file tray is cancelled in Ver.D cabinet to leave more space for future evolution.
Confidential Page 5 of 10
Product Change Notice
(B) The FAN 03C have the capacity of heat dissipation to support RFU(2*80W). The acoustic noise is
listed below.
Ver.B Ver.D
25 5.4bels 5.4bels (RFU(1*80W))
(RFU(1*80W)) 6.7bels (RFU(2*80W))
Confidential Page 6 of 10
Product Change Notice
Remark: There are three spare fuses of 30A in the right of new DCDU.
(C) The change of the input connection to support the parallel connection of 2 route 16mm2 cables.
(D) The change of output connectors to benefit installing. Plugging or unplugging the connector can
power on or off the load of the new version DCDU.
7.4 The change of DC power interface from customer and grounding cable.
Only when the Ver.D cabinet has more powerful RF configurations than Ver.B, the DC power interface
should be changed.
Cabinet
DC power interface from customer RFU types grounding
version
Confidential Page 7 of 10
Product Change Notice
cable
Remark: For the two routes 80A inputs of Ver.D, the power must come from the same power system external.
(A) The AC/DC power system will be installed into Ver.D cabinet in the site to decrease cabinet types.
(B) The change of power subrack name.
(C) The change of PSU and PMU. The power efficiency is improved much to save power loss.
Remark: The height is 1U only for PSU and PMU in new version cabinet. The old PSU and
PMU are 2U high.
(D) The change of subrack layout and DC power distribution
Confidential Page 8 of 10
Product Change Notice
Ver.B 6 x RFU(1*80W)
25A/3P (2.5mm2 cable), minimum.
220Vac three phase Ver.D
Ver.D 25A/3P (4 mm2 cable) 6 x RFU(2*80W)
Ver.B 6 x RFU(1*80W)
50A/2P (6mm2 cable), minimum
220Vac single phase Ver.D
8. Impact of Change
Some spare parts of the Ver.D Ver.D cabinet support much more Ver.D BTS supports
cabinet are different from the powerful RFU with some much higher traffic.
Ver. B cabinet. Therefore, a increased power consumption.
certain quantity of spare parts No more power consumption is
of the Ver. B cabinet must be increased for Ver.D cabinet using
reserved for future use. the same BBU and RFU modules
as Ver.B cabinet.
9. Involved Documents
The changes will affect the BTS3900 Product description and BTS3900 User Manual.
Confidential Page 9 of 10
Product Change Notice
10. Appendixes
None
11. Remarks