EN 480-8
Edition: 2010-12-15
Note:
Because of possible comments, the final version of this NORM can
differ from the present Draft.
Please send your comments (in writing) by 2011-01-31 to Austrian
Standards Institute.
Like all member organizations of CEN, Austrian Standards Institute is basically obliged to implement Euro-
pean Standards in Austria and to withdraw conflicting standards.
Austrian Standards Institute herewith submits this Draft of a European Standard as Draft NORM to
public enquiry and information.
Form For your comments/proposals for change, please use the relevant form
available from Internet. Download under
http://www.as-institute.at/norm-kann-mehr/normen-
entwickeln/loesungen-bieten/stellungnahme/
or use the Draft Standard Portal
http://www.as-institute.at/development/normenentwurfportal/
Structure Please use a new line for each comment. This facilitates the attribution
of the comments received to the different clauses and chapters of the re-
spective Draft.
Aspects concerning patent law The recipients of this Draft NORM are requested to add information on
any patent rights known to their comments and to provide supporting
documentation, if available.
AS+ Shop 22.02.2015
2
EUROPEAN STANDARD DRAFT
NORME EUROPENNE prEN 480-8
EUROPISCHE NORM
November 2010
English Version
Adjuvants pour bton, mortier et coulis - Mthodes d'essai - Zusatzmittel fr Beton, Mrtel und Einpremrtel -
Partie 8: Dtermination de l'extrait sec conventionnel Prfverfahren - Teil 8: Bestimmung des Feststoffgehalts
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 104.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 480-8:2010: E
worldwide for CEN national Members.
prEN 480-8:2010 (E) NORM DRAFT
Contents Page
Foreword ..............................................................................................................................................................3
Introduction .........................................................................................................................................................4
1 Scope ......................................................................................................................................................5
2 Principle ..................................................................................................................................................5
3 Apparatus ...............................................................................................................................................5
4 Procedure ...............................................................................................................................................5
5 Results ....................................................................................................................................................6
6 Test report ..............................................................................................................................................6
Bibliography ........................................................................................................................................................7
AS+ Shop 22.02.2015
2
NORM DRAFT prEN 480-8:2010 (E)
Foreword
This document (prEN 480-8:2010) has been prepared by Technical Committee CEN/TC 104 Concrete and
related products, the secretariat of which is held by DIN.
3
prEN 480-8:2010 (E) NORM DRAFT
Introduction
In 1996 the actual version of EN 480-8 Determination of the conventional dry material content was published
and introduced as European Standard. It has never been revised since that time. Using the test method
described in the standard in daily work for all types of admixtures it turned out quite fast not to be applicable
for an important part of concrete and mortar admixtures. For the solid content of admixtures based on
Lignosulfonates or sugars for example a reproducible and reliable result cant be obtained by the given test
method. By drying at 105 C a tight skin is formed on top of the test sample, preventing the water to be
completely evaporated within the given drying time of 4h.
The accuracy of the determination of the solid content of hygroscopic material is significantly influenced by the
use of an evaporating dish that cant be tightened for weighing. For practical reasons many labs today use
alternative test methods for the determination of the dry material content of these types of admixtures, as
stated by footnote d) in EN 934-1.
As a test method for concrete and mortar admixtures should be applicable for the most commonly used types
of products the current test method has to be revised. An adopted method has to be defined that can be
applied for these types of admixtures, too.
AS+ Shop 22.02.2015
4
NORM DRAFT prEN 480-8:2010 (E)
1 Scope
This European Standard describes a method for determining the conventional dry material content of an
admixture.
2 Principle
A sample of admixture is dried in an oven at (105 3) C until a constant weight is reached.
In the case of a liquid admixture this method shall be used to characterize the dry material content. For a
powder admixture this method shall be used to determine the actual mass of the dried powder.
NOTE This method is not suitable for determining the absolute solids content.
3 Apparatus
3.1 Weighing bottle, squat form, wide-mouthed with ground glass stopper or evaporating basin with a flat
bottom and approximately 75 mm diameter 45 mm depth.
3.3 Oven with forced ventilation, thermostatically controlled at (105 3) C, fitted with a temperature
indicating device.
The required temperature range shall be maintained throughout all parts of the oven used for this test.
NOTE Forced ventilation is necessary to ensure uniform temperature throughout the oven.
4 Procedure
Heat the weighing bottle with the stopper removed, or the evaporating basin, for at least one hour in a drying
oven at (105 3) C. After cooling for 30 min in a desiccator weigh the weighing bottle with stopper inserted,
or the evaporating basin. Repeat this procedure until the mass of the vessel is constant within a range of
1 mg.
Spread (2.0 0.2) g of the sample in a uniform layer on the bottom of the vessel and weigh to the nearest
1 mg).
NOTE 1 In order to obtain reproducible results it is essential that the mass of the dried residue or of the dried powder
will be large enough in relation to the dimensions and mass of the vessel and the mass of the sample.
Heat the weighing bottle with the stopper removed and contents, or the evaporating basin and contents, in the
oven at (105 3) C for a minimum of 1 h. Insert the stopper and transfer the weighing bottle, or evaporating
basin, to the desiccator. Allow to cool in the desiccator with the stopper removed. Insert the stopper and weigh
AS+ Shop 22.02.2015
the weighing bottle, or evaporating basin, to the nearest 1 mg. Repeat the heating for at least 30 min, allow to
cool in the desiccator and again weigh to the nearest 1 mg. Repeat the heating and cooling until two
successive weighings differ by no more than 2 mg. Record the lower mass.
Repeat the weighing and drying procedure using a fresh specimen from the same sample in order to obtain
duplicate results.