Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

OTDR report

Job info
Job ID : Reason :
Contractor : Operator A :
Customer : Operator B :
Test date : 1/7/2015 (9:04:47 AM GMT+7:00) File : core 2 pare-barru.trc

Cable info
Fiber ID : Fiber0005 Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 20.515 dB Avg. splice loss : 0.277 dB
Span length : 57.5717 km Max. splice loss : 2.100 dB
Average loss : 0.356 dB/km Span ORL : <18.41 dB

OTDR trace

dB

1
40.00

30.00
2 3 4 56
7
89 10
1112
20.00 13
1415
16
17
18 19
20 2122
23
24 31
10.00
25262728
29
30

0.00
10 20 30 40 50 km

Signature : _________________________ Date : 7/13/2017


EXFO E. O. Engineering Inc. Page 1 / 3
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level --- >-18.6 0.000


Fiber Section (2.0009 km) 0.584 0.292 0.584
2 2.0009 Positive Fault -0.200 0.385
Fiber Section (3.7466 km) 0.756 0.202 1.141
3 5.7475 Non-Reflective Fault 0.102 1.243
Fiber Section (3.1647 km) 0.769 0.243 2.012
4 8.9122 Non-Reflective Fault 0.120 2.132
Fiber Section (3.1749 km) 0.679 0.214 2.811
5 12.0870 Non-Reflective Fault 0.543 3.354
Fiber Section (0.4441 km) 0.128 0.287 3.481
6 12.5311 Non-Reflective Fault 2.100 5.581
Fiber Section (1.5058 km) 0.353 0.235 5.935
7 14.0369 Non-Reflective Fault 1.605 7.540
Fiber Section (0.9188 km) 0.193 0.211 7.733
8 14.9557 Positive Fault -0.799 6.934
Fiber Section (0.9086 km) 0.161 0.177 7.095
9 15.8642 Non-Reflective Fault 0.154 7.249
Fiber Section (2.9911 km) 0.593 0.198 7.842
10 18.8554 Non-Reflective Fault 0.155 7.997
Fiber Section (0.4237 km) 0.042 0.100 8.040
11 19.2790 Non-Reflective Fault 0.144 8.184
Fiber Section (0.6482 km) 0.130 0.200 8.314
12 19.9273 Non-Reflective Fault 0.209 8.523
Fiber Section (2.1234 km) 0.571 0.269 9.094
13 22.0507 Non-Reflective Fault 0.123 9.217
Fiber Section (0.2807 km) 0.076 0.272 9.293
14 22.3314 Positive Fault -0.148 9.145
Fiber Section (0.7912 km) 0.270 0.341 9.415
15 23.1226 Non-Reflective Fault 0.470 9.885
Fiber Section (0.6789 km) 0.068 0.100 9.953
16 23.8015 Non-Reflective Fault 0.471 10.424
Fiber Section (4.6347 km) 0.964 0.208 11.388
17 28.4362 Non-Reflective Fault 0.768 12.156
Fiber Section (1.1178 km) 0.230 0.205 12.386
18 29.5541 Non-Reflective Fault 0.130 12.515
Fiber Section (1.9856 km) 0.518 0.261 13.033
19 31.5396 Non-Reflective Fault 0.166 13.200
Fiber Section (4.5020 km) 0.887 0.197 14.087
20 36.0417 Non-Reflective Fault 0.283 14.370
Fiber Section (3.0983 km) 0.717 0.232 15.088
21 39.1400 Non-Reflective Fault 0.218 15.305
Fiber Section (0.9086 km) 0.176 0.193 15.481
22 40.0486 Non-Reflective Fault 0.096 15.577
Fiber Section (5.9261 km) 1.338 0.226 16.915
23 45.9747 Non-Reflective Fault 0.260 17.175
Fiber Section (0.5870 km) 0.059 0.100 17.234
24 46.5617 Non-Reflective Fault 1.062 18.296
Fiber Section (2.4246 km) 0.442 0.182 18.738
25 48.9862 Positive Fault -0.796 17.942
Fiber Section (1.0362 km) 0.186 0.179 18.128
26 50.0224 Non-Reflective Fault 0.247 18.375
Fiber Section (1.0974 km) 0.110 0.101 18.485
27 51.1198 Non-Reflective Fault 0.835 19.320
Fiber Section (0.8882 km) 0.223 0.251 19.543
28 52.0080 Positive Fault -0.261 19.282
Fiber Section (4.4459 km) 0.880 0.198 20.162
29 56.4539 Non-Reflective Fault 0.422 20.583
Fiber Section (0.3624 km) 0.077 0.212 20.660
30 56.8163 Positive Fault -0.435 20.225

Signature : _________________________ Date : 7/13/2017


EXFO E. O. Engineering Inc. Page 2 / 3
OTDR report
Events table Continued
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

Fiber Section (0.7554 km) 0.290 0.384 20.515


31 57.5717 Reflective Fault --- -17.5 20.515

Marker info
A : 0.0000 km, 20.130 dB B : 0.0088 km, 33.839 dB
a : 0.0000 km, 20.130 dB b : 0.0133 km, 46.152 dB
A to B distance : 0.0088 km, -13.709 dB A to B ORL : 71.66 dB
3-pt. reflectance : ***** A to B LSA att. : -1342.879 dB/km
4-pt. Ev. loss : -13.711 dB

Test and cable setup


Wavelength : 1550 nm (SM-9m) Acq. time : 15 s
Filename : core 2 pare-barru.trc Pulse width : 2.5 s
Hardware : FTB-7500E-023B-EI Helix factor : 0.00 %
Serial number : 766090 Splice loss threshold : 0.020 dB
Software : N/A Reflectance threshold : -72.0 dB
Range : 60.0000 km End-of-fiber threshold : 5.000 dB
IOR : 1.468325
RBS : -81.87

Signature : _________________________ Date : 7/13/2017


EXFO E. O. Engineering Inc. Page 3 / 3