Professional Documents
Culture Documents
Cap Bank Prot PDF
Cap Bank Prot PDF
CAPACITOR BANK
PROTECTION & CONTROL SYSTEM
Key Benefits
Protect capacitor banks of a variety of configurations with Custom programmable logics for advanced shunt capacitor
sensitive current and voltage balance protection functions bank controls
Complete IEC 61850 Process Bus solution providing resource Flexible Automatic voltage regulation of shunt capacitor
Applications
Protection, Control, Monitoring and Automation of shunt Sensitive protection for grounded, ungrounded single and
capacitor banks of different voltage levels parallel capacitor banks and banks with taps, for a variety of
Suitable for protecting multiple capacitor banks capacitor bank configurations
Shunt capacitor banks based AVR and Capacitor control
supervision
Features
Features
Protection and Control IEC 61850 Process Bus Interface
Voltage differential protection Robust communications with up to 8 HardFiber Bricks
Compensated Bank Neutral Voltage Unbalance Seamless integration with existing C70 functions
Phase Current Unbalance and Neutral Current Unbalance Redundant architecture for dependability and security
protection
Bank phase overvoltage Monitoring and Metering
Negative sequence over voltage Metering - current, voltage, power, energy, frequency
User programmable logics for custom schemes Oscillography analog and digital parameters at
64 samples/cycle
Automatic Voltage Regulator (AVR) for switching capacitor
banks based on voltage, power factor and reactive power Event Recorder - 1024 time tagged events with 0.5ms scan of
digital inputs
Time and Date function allowing capacitor bank switching
based on time of day, week and seasons. Data Logger - 16 channels with sampling rate up to
1 sample / cycle
Capacitor control supervision block for processing
commands from SCADA, remote communication and local Advanced relay health diagnostics
control through front panel HMI Setting Security Audit Trail for tracking changes to C70
configuration
Communications
Networking interfaces 100Mbit Fiber Optic Ethernet, RS485, EnerVistaTM Software
RS232, RS422, G.703, C37.94 Graphical Logic Designer and Logic Monitor to simplify
Multiple Protocols - IEC61850, DNP 3.0 Level 2, Modbus RTU, designing and testing procedures
Modbus TCP/IP, IEC60870-5-104, Ethernet Global Data (EGD) Document and software archiving toolset to ensure
Direct I/O secure, high-speed exchange of data between reference material and device utilities are up-to-date
URs for Direct Transfer Trip and I/O Extension applications EnerVistaTM Integrator providing easy integration of data in
Embedded Managed Ethernet Switch with 4 - 100 Mbit Fiber the C70 into new or existing monitoring and control systems
optic ports and 2 copper ports
g Multilin
393
C70 Capacitor Bank Protection and Control System
394 www.GEMultilin.com
C70 Capacitor Bank Protection and Control System
www.GEMultilin.com 395
C70 Capacitor Bank Protection and Control System
Neutral Current Unbalance or the single phase auxiliary voltage. Two FlexLogic
applications using the reactive power/power FlexLogic is the powerful UR-platform
Based on the balance between
factor path are shown below. programming logic engine that provides
interconnected neutral current of two
Specialized Protection & Control
parallel banks and is applicable to both the ability of creating customized protection
Time and Date Function
grounded and ungrounded banks. and control schemes thereby minimizing the
Provides the user with ability to program need, and the associated costs, of auxiliary
Grounded banks require a window CT.
certain actions based on time. components and wiring.
Each element has four independent
5 time of day timers Using FlexLogic, the C70 can be
stages; each stage has independent
User accessible time/date information for programmed to provide required tripping
threshold and time delay settings.
more sophisticated custom schemes, that logic along with custom scheme logic for
Provision to set the bank unbalance dynamic setting group changes.
respond to weekdays, weekends, summer
factors manually, or by selecting
or winter
the auto-setting feature. The bank Scalable Hardware
unbalance factor can be calculated The C70 is available with a multitude of I/O
automatically under user supervision configurations to suit the most demanding
either locally or remotely. application needs. The expandable modular
One neutral current unbalance element design allows for easy configuration and
provided per CT/VT module, up to a future upgrades.
maximum of three. Multiple CT/VT configurations allow
for implementation of many different
schemes
Control Flexible, modular I/O covering a broad
The C70 is provided with built-in control range of input signals and tripping
functions to help end users build capacitor Capacitor Control Supervision schemes
bank control schemes of their choice with This feature supervises the capacitor
ease and flexibility. bank open and close commands from the
command sources including the Relay
Automatic Voltage Regulator
front panel HMI (push buttons), AVR and
The AVR is a capacitor bank controller SCADA/HMI.
responding to either voltage, reactive
power, or power factor. One AVR element
is provided per CT/VT module, up to a Advanced Automation
maximum of three. The AVRs can operate The C70 incorporates advanced automation
independently, each on their own section features including powerful FlexLogic
of the bank, or only the one set for present programmable logic, communication, and
conditions/time-of-day, as determined by SCADA capabilities that far surpass what is
FlexLogic (user programmable logic). For found in the average capacitor bank relay.
the voltage control path, a provision is The C70 integrates seamlessly with other UR
made to operate from any phase-phase relays for complete system protection.
voltage (VAB, VBC, VCA), average voltage
(VAVER), positive-sequence voltage (V1) Capacitor control supervision block
396 www.GEMultilin.com
C70 Capacitor Bank Protection and Control System
FlexLogicTM Designer
test its own major functions and critical
hardware. These diagnostic tests monitor
for conditions that could impact security
and availability of protection, and present
device status via SCADA communications
and front panel display. Providing
continuous monitoring and early detection
of possible issues helps improve system
uptime.
Communications
FlexlogicTM allows for customizing the C70 outputs for capacitor bank protection schemes and applications. The C70 provides advanced commun-
ications technologies for remote data and
engineering access, making it easy and
RTDs and DCmA inputs are available to current, and power metering are built into
www.GEMultilin.com 397
C70 Capacitor Bank Protection and Control System
advanced interlocking, generation rejection Multilin products. The setup software within
and other special protection schemes. Launchpad allows configuring devices in EnerVistaTM Integrator is a toolkit that allows
real-time by communicating using serial, seamless integration of GE Multilin devices
Communication with up to 16 UR relays Ethernet, or modem connections, or offline into new or existing automation systems.
in single or redundant rings rather by creating setting files to be sent to devices Included in EnerVista Integrator is:
than strictly limited to simplistic point- at a later time.
to-point configurations between two Included in Launchpad is a document OPC/DDE Server
devices archiving and management system that GE Multilin Drivers
Connect to standard DS0 channel ensures critical documentation is up-to-date Automatic Event Retrieval
banks through standard RS422, G.703 and available when needed. Documents
Automatic Waveform Retrieval
or IEEE C37.94 interfaces or via direct made available include:
fiber optic connections
Manuals
No external tester required to provide
channel diagnostic information Application Notes
Record the operation of the internal C70 elements and external connected
devices with 1ms time-stamped accuracy to identify the Sequence of Operation Analyze capacitor bank faults using both analog and digital power system
of station devices during capacitor bank faults and disturbances. quantities that are measured and recorded up to a rate of 64 samples per cycle.
398 www.GEMultilin.com
C70 Capacitor Bank Protection and Control System
LED Indicators
User Interface
The C70 front panel provides extensive local
HMI capabilities. The local display is used Multi-Language
for monitoring, status messaging, fault Display
English
diagnosis, and device configuration. User
Russian
configurable messages that combine text French
with live data, can be displayed when user- Chinese
defined conditions are met.
B
52
C
F1b
F2a
F2b
F3a
F3b
F4a
F4b
F5a
F6a
F7a
F8a
L1a
L1b
L2a
L2b
L3a
L3b
L4a
L4b
L5a
L6a
L7a
L8a
F1c
F2c
F3c
F4c
F5c
F6c
F7c
F8c
L1c
L2c
L3c
L4c
L5c
L6 c
L7c
L8c
VB
VC
VB
VC
VA
VX
VA
VX
IG
IG
IG1
IG1
IA
IC
IC
IB
IC1
IA
IB
IA1
IC1
IB1
IA1
VB
IB1
VC
VB
VC
IG5
IG5
VA
VX
VA
VX
IC5
IC5
IA5
IB5
IA5
IB5
VOLTA VOLTA
8F 8F
U3c
S1c CONTACT 1c
I U4a
S2a CONTACT 2a
U4 U4b
S2c CONTACT 2c V
U4c
S1b C
I U5a
S3a CONTACT 3a U5 U5b
V
S3c CONTACT 3c U5c
S4a CONTACT 4a I U6a
S4c CONTACT 4c U6 U6b
V
S3b C U6c
S5a CONTACT INPUT S5a
N1a
6C
S5c CONTACT 5c
N1 N1b
S6a CONTACT 6a
N1c
S6c CONTACT 6c
N2a
S5b C
N2 N2b
S7a CONTACT 7a N2c
S7c CONTACT 7c N3a
S8a CONTACT 8a N3 N3b
S8c CONTACT 8c N3c
DIGIT
N4a
Multilin
S7b C
S8b SURGE N4 N4b
N4c
C70 COMPUTER
B1b N5a
CRITICAL 1 1 8
B1a N5 N5b
FAILURE 2 2 3 RXD
B2b N5c TXD
DC
B3a
B3b OUTPUT C70 N6
N6a
N6b
RXD 3
4
SGND 5
3
4
5
2 TXD
20
7 SGND
Pr
B5b HI N6c
CONTROL 6 6 6
B6b LO N7a
POWER
B6a N7 N7b 7 7 4
*Fibre B8a
B8b
SURGE
FILTER
Contr elay N7c
N8a
8
9
8
9
5
22
P
Optic
DIGIT
N8 N8b
D1b10BaseFL
Tx1 N8c
RS485
NORMAL
D2bRx1 CONNECTOR CONNECTOR
C
D3b10BaseFL
Tx2 com COM
ALTERNATE
D1aRx2 1
RS485
Shielded D2a C
10BaseT
D3a com
Remote
Device D4b
D1a
RS485 RS-232
D4a
D2a IRIG-B
input DB-9
D3a BNCcom
D4b (front)
PERSONAL
D4a BNC IRIG-B
IRIG-B COMPUTER
output
Input
Co-axial BNC
IRIG-B
Co-axial BNC Output
Minimum
X W V U T S R P N M L K J H G F D B
6 6 6 8 6 8 9 1
Inputs/ Inputs/ Inputs/ CT/ Inputs/ CT/ CPU Power
outputs outputs* outputs VT outputs VT supply
PROVIDED * * *
www.GEMultilin.com 399
C70 Capacitor Bank Protection and Control System
Ordering
C70 - * 00 - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** For full sized horizontal mount
Base Unit Base Unit
CPU E RS485 + RS485 (IEC61850 option not available)
G RS485 + Multi-mode ST 10BaseF
H RS485 + Mutli-mode ST Redundant 10BaseF
J RS485 + Multi-mode ST 100BaseFX
N RS485 + 10/100 BaseT
S RS485 + 6 port, 100 Mbps, Managed Ethernet Switch
Software Options 00 None
03 IEC61850
12 Enhanced Capacitor Bank Control (AVR, Capacitor Control Supervision,
Time & Date)
13 Enhanced Capacitor Bank Control (AVR, Capacitor Control Supervision,
Time & Date) + IEC61850
Mounting / Conformal Coating H Horizontal (19 rack) - Standard
A Harsh Chemical Environment Option
User Interface K Enhanced English Front Panel
L Enhanced English Front Panel with User-Programmable Pushbuttons
M Enhanced French Front Panel
N Enhanced French Front Panel with User-Programmable Pushbuttons
Q Enhanced Russian Front Panel
T Enhanced Russian Front Panel with User-Programmable Pushbuttons
U Enhanced Chinese Front Panel
V Enhanced Chinese Front Panel with User-Programmable Pushbuttons
F Vertical Front Panel with English display
Power Supply H 125/250 V AC/DC
L 24 - 48 V (DC only)
CT/VT DSP 8L 8L 8L Standard 4CT/4VT w/ enhanced diagnostics
Specialized Protection & Control
Ordering Note: To view the latest options available for the C70, or to order the UR Classic Front Panel, please visit our online store for more details.
080626-v1
400 www.GEMultilin.com