Page 1

KLAUS Multiparking Systems Pvt. Ltd.


- Section
5/3, Prashant Apartments, Erandwane,
PRODUCT DATA
- Dimensions Pune 411 004 INDIA
- Car data
Phone +91-20-2545 0378 / 8662 Parking Automat P310
Page 2 Fax +91-20-2544 6360
- Door E-mail info@klausmultiparking.in
2000 kg 1
- Width Website www.klausindia.com
dimensions

Page 3 25 Free space 30 20 Free space Dimensions


- Width
145
dimensions
Tolerances for space requirements +30 . 3
- Approach
Dimensions in cm.
45

55
- Free Suitable for
spaces
OG (upper floor) Standard passenger cars
Page 4 According to clearance and maximal
- Function surface load
- Load plan
Standard
Page 5 Width 190 cm 4
- Electrical Weight max. 2000 kg

Detail doors
data

see page 2
EG (ground floor)
- Technical Wheel load max. 500 kg
data
- To be
performed Clearance profile
by the
customer 160 30

45

55
see table
Page 6
- Description
UG (lower floor)
150
0
Grounding 6 0 13
6
100 125
500 (520)

10

2% 2%
40 8 Water drainage 7 25 8
+5
550 0 for vehicle up to 5.00 m = 164 long
+5
(570 0 for vehicle up to 5.20 m = 17 long) 9

P310-175 P310-200 P310-230


345 5

405 5

430 5
175

200

230

Car height Car height Car height


Height OG EG UG Height OG EG UG Height OG EG UG
345 150 170 150 405 175 205 175 435 200 200 200

1 Standard type 7 Slope with drainage channel and sump.


Parking Automat P310 | Indian Version 01.2014

2 Spare no. 8 These floor areas need to be horizontal and equal level across
3 To follow the minimum finished dimensions, make sure to the full width of the pit.
consider the tolerances, during construction. 9 For convenient use of your parking space and due to the fact
4 Car width for platform width 230 cm. If wider platforms are that the cars keep becoming longer we recommend a pit
used, it is also possible to park wider cars. length of 570 cm.
5 10 At the transition section between pit floor and walls no hollow
If height H is larger, vehicles with the maximum height as
applicable for the EG can be parked on the OG, provided moldings/ coves are possible. If hollow moldings/ coves are
there is free space available on the ceiling. required, the systems must be designed smaller or the pits
accordingly wider.
6 Potential equalization from foundation grounding connection
to system (provided by the customer). If sprinklers are required, make sure to provide the
! necessary free spaces during the planning stage.
Parking Automat P310 | Indian Version 01.2014 Page 2 of 6

Page 1 Garages with sliding doors (standard) | Width dimensions


- Section
- Dimensions
Sliding door behind columns Sliding door between columns Sliding door in front of columns
- Car data

Page 2
- Door 13
13 13 25
- Width 25 25
dimensions

H
Page 3

H111

H111

H111

H3
H2

H2

H2
- Width
dimensions
- Approach

30
- Free
spaces

PD

PD

PD
Page 4
- Function
- Load plan
550 (570) 550 (570) 550 (570)
Page 5
- Electrical
data
Type PD H H1 H2 Type PD H H1 H2 Type PD H H1 H2 H3
P310-175 175 345 170 210 P310-175 175 345 170 220 P310-175 175 345 170 210 220
- Technical
data P310-200 200 405 205 220 P310-200 200 405 205 230 P310-200 200 405 205 220 230
P310-230 230 430 200 220 P310-230 230 430 200 230 P310-230 230 430 200 220 230
- To be
performed
by the
customer Columns per each grid unit Columns per each grid unit Columns per each grid unit
Page 6
- Description Not available
RB RB RB
RB RB RB

(25) 13
10 10

(B2) 20 20
(B2)
B1 B2 B1 B2
no. of grids x RB + 20 no. of grids x RB + 20
Driveway in accordance
Driveway in accordance
with local regulations
with local regulations

Usable platform width RB 12 B1 B2 Usable platform width RB 12 B1 B2


220 240 240 220 220 240 240 220
230 250 250 230 230 250 250 230
240 260 260 240 240 260 260 240
250 270 270 250 250 270 270 250
260 280 280 260 260 280 280 260
270 290 290 270 270 290 290 270

Columns every second grid unit Columns every second grid unit Columns every second grid unit

RB RB RB RB RB RB RB RB
RB RB RB RB

(25) 13
10 10 10

(B4) 20
(B4) 20 B3 B4 20
(B4)
B3 B4 no. of grids x RB + 20
Driveway in accordance B3 B4
no. of grids x RB + 20
with local regulations no. of grids x RB + 20
Driveway in accordance
with local regulations Driveway in accordance
with local regulations

Usable platform width RB 12 B3 B4 Usable platform width RB 12 B3 B4 Usable platform width RB 12 B1 B5


220 240 480 460 220 240 480 460 220 240 480 460
230 250 500 480 230 250 500 480 230 250 500 480
240 260 520 500 240 260 520 500 240 260 520 500
250 270 540 520 250 270 540 520 250 270 540 520
260 280 560 540 260 280 560 540 260 280 560 540
270 290 580 560 270 290 580 560 270 290 580 560

End parking spaces are generally more difficult to drive into. Therefore, we recommend our wider platforms for end parking spaces. Parking
! larger vehicles on standard width platforms may make getting into and out of the vehicle difficult. This depends on the type of the vehicle,
approach and above all, on the drivers skill.

11 H1 = Height of the vehicle on ground floor (EG) platform.


12 RB = Grid unit width must strictly conform to dimensions quoted.
13 Applies to manually operated doors only. The electricity driven doors must have 35 cm.
Parking Automat P310 | Indian Version 01.2014 Page 3 of 6

Page 1 Garages with roll doors | Width dimensions


- Section
- Dimensions Roll door behind columns Columns per each grid unit
- Car data

Page 2
- Door
15 70
- Width RB RB RB

35
dimensions

Page 3 10
- Width

H
dimensions

H1 11
- Approach

H2
- Free 20 20 20 20
spaces

30
B5 B5
Page 4 no. of grids x RB + 20
35 Driveways in accordance

PD
- Function
with local regulations
- Load plan

Page 5
550 (570)
- Electrical
data
- Technical
Usable platform width RB 12 B5
data 220 240 220
- To be
Roll door 230 250 230
performed Type PD H H1 H2 height 240 260 240
by the P310-175 175 345 170 210 263 250 270 250
customer P310-200 200 405 205 220 300 260 280 260
P310-230 230 430 200 220 300 270 290 270
Page 6
- Description

End parking spaces are generally more difficult to drive into. Therefore, we recommend our wider platforms for end parking spaces. Parking
! larger vehicles on standard width platforms may make getting into and out of the vehicle difficult. This depends on the type of the vehicle,
approach and above all, on the drivers skill.

11 H1 = Height of the vehicle on ground floor platform.


12 RB = Grid unit width must strictly conform to dimensions quoted.

Approach

!
Maximum
descending Maximum
slope 3% ascending
slope 5%

The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneuvering
! and positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility.

Longitudinal free space

10 RB 12 RB RB RB
Logitudinal
free space
45

20

Empty
space Entrance level

12 RB = Grid unit width must strictly conform to dimensions quoted.


Parking Automat P310 | Indian Version 01.2014 Page 4 of 6

Page 1 Function with standard numbering and identification of parking levels


- Section
- Dimensions e.g. for parking space No. 8:
- Car data Check first that all doors are closed, then select No. 8 on operating panel.
Page 2

Entrance level
- Door
OG 1 3 6 1 3 6 1 3 6
- Width
dimensions

Page 3 EG 4 7 4 7 4 7 8
- Width
dimensions
- Approach UG 2 5 8 2 5 8 2 5
- Free
spaces

Page 4
- Function For driving the vehicle off platform The empty space is now above the The vehicle on platform no. 8 can
- Load plan No. 8 the ground floor parking vehicle which shall be driven off now be driven off the platform.
platforms are shifted to the left. platform. Platform no. 8 will be lifted.
Page 5
- Electrical
data Load plan
- Technical
data P310-175 P310-200 P310-230
- To be
performed
by the
customer F1 F1 F1
F6 F6 F6
H3

Page 6
H3

H3
- Description
H

F1
F1

H
H4

F1
185

H4
F6 F1

H4
185

F1F2
F1 F2

185
F7 F1 F2
F7 F1 F2
165

PD
140

F7
F3 F4 F5 F8 F9
165
190

PD

195
F3 F4 F5

220

PD
F8 F9
6 6 F3 F4 F5 F8 F9
550 (570)
6 6
550 (570)
6 6
550 (570)
Type PD H H3 H4 Type PD H H3 H4 Type PD H H3 H4
P310-175 175 345 150 260 P310-200 200 405 185 295 P310-230 230 430 185 295

Load plan-top view


RB2 RB RB RB RB

F3 F4 F5 F4 F5 F4 F5 F4 F5 F4 F3

F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2

F6 F7 F6 F7 F6 F7 F6 F7 F6 F7 F6 F7

F8 F9 F9 F9 F9 F8

RB1 RB RB RB RB1

Usable platform width RB 12 RB1 RB2 Platform load F1 F2 F3 F4 F5 F6 F7 F8 F9 13


220 240 250 125 2000 kg 5 2,5 14,5 +70 29 0,2 2,5 +25 +50
230 250 260 135
240 260 270 140
250 270 280 145
260 280 290 150
270 290 300 155

The system is doweled to floor and walls. The drilling depth in the floor is approx. 15 cm. The drilling depth in the walls is approx. 12 cm.
! Floor and walls are to be made of concrete (grade of concrete min. C20/25)
The dimensions for the points of support are rounded values. If the exact position is required, please contact KLAUS Multiparking.

12 RB = Grid unit width must strictly conform to dimensions quoted


13 All forces in kN (static loads)
Parking Automat P310 | Indian Version 01.2014 Page 5 of 6

Page 1
Electrical data
- Section
- Dimensions
Control box Electrical supply to the control box/Foundation earth
- Car data
connector
The control box must be accessible at all times from outside.
Page 2 3 phase, 415 VAC (10%), 50 Hz (2%), 4 wire (3 PH + N + PE)
- Door Dimensions approx. 100 x 100 x 30 cm.
electrical supply to the control box through a 4 pole RCBO (or MCB +
- Width Cutting through of wall from control box to parking system (contact the ELCB), 25 Amp. IDN (sensitivity/leakage current)100 mA.
dimensions local agency of KLAUS Multiparking for clarification).
Supply line cable 5 x 4.0 mm2, copper (3 PH + N + PE) with marked
Page 3 wire and protective conductor. Local regulations must be taken into
- Width consideration.
dimensions
- Approach Electrical supply to the control box must be provided by the customer
- Free during installation. The functionality can be monitored on site by our
spaces Cutting through fitters together with the electrician. If this cannot be done during
installation for some reason for which the customer is responsible, the
Page 4 customer must commission an electrician at his own expense and risk.
- Function
Safety of machinery, electrical equipment, grounding of the steel
- Load plan
structure is necessary, provided by the customer (distance between
Page 5
grounding max. 10 m).
- Electrical
data Operating device
- Technical
data Easy-to-survey positioning (e.g. on column).
- To be Parking system fully visible Protection against unauthorized use.
performed
by the from control box May also be recessed in wall if required.
customer

Page 6
- Description

Technical data
Field of application Numbering
Generally parking system is suitable for the same car length for which Standard numbering of the parking spaces:
the wheel-stop is adjusted at the time of installation. In case different
car is to be parked, wheel-stop adjustment confirmation from KLAUS 1 3 6 9
Multiparking shall be required.
Empty 4 7 10 Entrance level
Care space

To avoid damages resulting from corrosion, make sure to follow our 2 5 8 11


cleaning and care instructions and to provide good ventilation of your
garage.
Initial position: lower floor platform No. 2 at entrance level (covering of
Environmental conditons pit, safety regulation).
Different numbering is only possible at extra cost.
Environmental conditions for the area of Multiparking systems.
0
Temperature range +50C to +40 C. Relative humidity 50% at a Please take note of the following specifications.
maximum outside temperature of +400 C. In general, the empty space must be arranged to the left.
If lifting or lowering times are specified, they refer to an environmental The numbers must be provided 8-10 weeks before the delivery date.
temperature of +100 C and with the system set up directly next to the
hydraulic unit. At lower temperatures or with longer hydraulic lines,
these times increase.

To be performed by the customer

Safety fences Strip footings


Any constraints that may be necessary in order to provide protection If due to structural conditions strip footings must be effected, the
for the park pits for pathways directly in front, next to or behind the unit. customer shall provide an accessible platform reaching the top of the
This is also valid during construction. said strip footings to enable and facilities the mounting work.

Numbering of parking spaces Electrical supply to the control box/Foundation earth


connector
Consecutive numbering of parking spaces.
Suitable electrical supply to the control box must be provided by the
Building services customer during installation. The functionality can be monitored on
site by our fitters together with the electrician. If this cannot be done
Any required lighting, ventilation, fire extinguishing and fire alarm during installation for some reason for which the customer is
systems as well as clarification and compliance with the relevant responsible, the customer must commission an electrician at his own
regulatory requirements. expense and risk.
Drainage Safety of machinery, electrical equipments, grounding of the steel
structure is necessary, provided by the customer (distance between
For the middle area of the pit, we recommend a drainage channel, grounding max. 10 m).
which is connected to a floor drain system or sump (50 x 50 x 20 cm).
The drainage channel may be inclined to the side, however not the pit Door suspension
floor itself (longitudinal incline is available). In the interest of
environmental protection we recommend painting the pit floor. Oil and The lintel height H2 (see page 2) is absolutely necessary. With
petrol separators must be provided according to the statutory differing heights, additional fixings are required at extra cost.
provisions when connecting to the public sewage system.
Door shields
Wall cuttings
Door shields may be necessary. If desired, they can be ordered from
Any necessary wall cuttings. KLAUS Multiparking for an additional cost.
Parking Automat P310 | Indian Version 01.2014 Page 6 of 6

Page 1 Description
- Section
- Dimensions General description Drive unit of transversely movable platforms on the ground
- Car data floor (EG)
KLAUS Multiparking System provides independent parking spaces for
Page 2 cars, one on top of the other and side by side. - Gear motor with chain wheel
- Door
Dimensions are in accordance with the underlying dimensions of - Chains
- Width
dimensions
parking pit, height and width. - Running and guide rollers (low-noise)
The parking bays are accessed horizontally. - Power supply via cable
Page 3
- Width Along the complete width of the Parking Automat, an approach lane
dimensions (during lane in accordance with local regulations) must be available.
- Approach Parking spaces are arranged on three different levels, one level on top Hydraulic unit consists of
- Free of the other. - Hydraulic power unit (low-noise, installed onto a console with a
spaces
The platforms of both the lower floor (UG) and upper floor (OG) are metal mounting)
Page 4 moved vertically, the platforms of the ground floor (EG) horizontally. At - Hydraulic oil reservoir
- Function
approach level (EG) there is always one parking space less available.
This vacant space is used for shifting the ground floor (EG) parking - Oil filling
- Load plan
spaces sideways, thus enabling an upper floor (OG) parking space or - Internal geared wheel pump
Page 5 lower floor (UG) parking space to be lowered or lifted to approach
level. Consequently, a unit of five parking spaces (2 on the upper floor, - 3-phase-AC-motor (3.0 kW, 415 VAC, 50 Hz)
- Electrical
data 1 on the ground floor, 2 on the lower floor) is the smallest unit available - Pressure gauge
- Technical for this parking system. - Pressure relief valve
data
The Parking Automat P310 allows parking of passenger cars and - Hydraulic hoses
- To be
performed station wagons.
by the
customer
For safety reasons, it is recommended to install safety doors at the
entrance. Control system
Page 6
- Central operator panel (operating device ) used to select the desired
- Description
A steel framework mounted inside the pit consists of parking space.
- Supports - With series installation, the doors are opened manually.
- Steel pillars with sliding platform supports - Electric wiring is made from the electric cabinet by the manufacturer.
- Cross and longitudinal members
- Running rails for the transversely movable ground floor (EG) platform Laterally movable doors
Size
Platforms consist of
Sliding door, dimensions: approx. 2500 mm x 2000 mm
- Side members
(width x height).
- Cross members
Frame
- Platform base sections
- Frame construction with vertical centre stay made from extruded
- 1 wheel-stop (on the left per parking space) aluminium sections.
- Screws, small parts, etc. Safety doors
Doors and door suspensions are not included in the standard version
Lifting device for upper floor (OG) and lower floor (UG) but can be delivered at additional cost as special equipment.
platforms
Door actuation
- Hydraulic cylinder with solenoid valve - Manually, i.e. the door is opened and closed by hand
- Chain wheel For safety reasons the movement of the platforms as always mode
- Chains behind locked doors.
- Limit switches Door rails
- The platforms are suspended on four points and guided along the - The running gear of each door consists of 2 twin-pair rolling gadgets,
supports using plastic sliding bearings. adjustable in height
- The running rails of the doors are fixed to brackets or the concrete
lintel, or on a building-specific door suspension using ceiling fittings
- The guide consists of 2 plastic rollers mounted to a base late, which is
doweled to the floor

We reserve the right to change these specifications without prior notice.


KLAUS Multiparking reserves the right in the course of the technical progress to use newer or other technologies, system, processes,
procedures or standards in the fulfillment of their obligations other than those originally offered.