Download as pdf
Download as pdf
You are on page 1of 4
@& ORTEX PASSIVE INFRARED DETECTOR CX-502AM/502 (Anti-Masking Model) (Standard Model) Optex's Multi Anti-Masking Technology prevents any detector disturbance. 1 Multi Anti-Masking Technology with Highly-Sensitive Selt- Checking Function Double Conductive Shielding of Pyroelectric Element for accurate detection Quad Zone Logic prevents false alarms caused from i ‘spot temperature changes ™ Low Current Draw, Anti-Magnet and Silent Relays thanks to the Photoelectric MOS Relay lp lt CO Set Optex has developed the world’s first Multi Anti-Masking ‘Technology. By employing multiple technologies. (CX-502's Anti-Masking Technology will detect virtually any attampt to mask the detector. Whether invisible ‘spray, black spray, transparent tape, or even black paper is used, the Multi Anti-Masking Tech will detect the attempt. Our unique design of integrated technologies provides the widest range of protection against masking Techniques and produces a sensor with the highest, degree of reliability ever offered. inti spray detection ay aaa Pe rc recogni ‘maoking objet (gi sae racial at th A eecton of diturbances in on of The Sel-Check function is an onboard circuit which checks the operation of the detector at rogular 5 hour intorvals. This ensures that the unit is always working correctly. This function indicates by a flickering LED which detector is activated first when several detectors are connected in one alarm loop. asking PIR De (CX-502 SERIES STABLE DETECTION PERF @ Quad Zone Logic (Patent Listed) ‘The highly accurate and reliable detection pattern wil ‘maintain its sensitivity through the entire detection area ‘even in high temperature or low contrast environments. Quad Zone Logic creates an extremely high vertical zane density, two or three times the size of conventional PIRS. These taller zones capture the entire body mass and ‘enable detection of even the smallest temperature contrast against the temperature of the background. In addition, the vertical election density has been improved to take into account | fs dead zones created | {} by furniture or partitions. ma tae Conventional Wedels Et ector Eliminates False Alarms Séisitivty Selector ‘Tamper Switch @ Advanced Temperature Compensation Temperature Compensation wil increase detection capability under high temperature conditions where the background temperature is similar to that of the human body. It maintains a high level of false alarm protection while providing accurate detection by automatically ‘adjusting its sensiiity according to the environmental temporature. @ Sealed Optics Prevents drafts and small insects from geting onto the Pyroelectric Element. This practically eliminates the ‘chance of false alarm due to these causes since the Pyro is sealed with the inside moiding ofthe housing cover. @ Selectable Sensitivity (High, Medium, Low) @ Selectable Pulse Count (Standard or Special) @ LED On/Off Switch @ Stream Lined Offset Spherical Lens @ Durable & Add nal PCB Protection Cover @versions @options CX-SOZAM-ANi-Masking -EAcTW: Wall Mount Bracket ‘Soi-Checking_-FACTW : MutsAngle Wall Bracket Inia Alarm FA2C: Mut-Angle Coling Memory Brackot Cx-502 Standard ‘CL-B0N: Long Range Lens (©x-502V “Alarm Memory ome 7.78 (24m x2.3m) FALSE ALARM PROTECTION @ Double Condu Element (Patent Listed) Double ftering and conductive ‘metal shielding of the Pyro block out visible ight and RFI allowing only infrared energy to reach the pyroelectric. elements, @ RFI Protection 'No alarm from a fold strength of 80V/m within the range of 144 to 1,200MHz. @ Temperature Protection ‘No alarm in high, low and changing temperatures from -4'F to H2ZF (-20C to +50°C) OTHER OUTSTANDING FEATURES @ Easy Installation Easy Wiring Knockout and the Easy-to-Viow LED help you to install the unit more simply. ible Light Protection @ Low Current Draw Drastic energy consumption reduction compared with conventional madels, (CX-SO2AM : 7mA (CX-502AMVes: mA) (©X-502 and OX-502V : 5mA @ Anti-Magnet By employing the Photoelectric MOS Relay, the CX-502 series isnot affected by magnetized materials. @Silent-Relay DETECTION PATTERNS SPECIFICATIONS ex-502 a Passive itared ‘roe angle 85 wide Soft 50M (15m x 15m) ‘2 zone 6 1081830) ‘SF (1.6 ©) a isco. (0.6misee) 1 ssc. (0.3 ~ 1.msec.) @= 16V00 [5A noel) / 129A (mas) ‘App. 1 min, (LED blinks) LED is blinking during warmup period. ‘Alarm condton 44202 (1209) Ginekol) ‘The CX series represents superior detection performance where iminating false alarms, even in cx-7om Zot» 7H (21m x24m) {son x en (asm x26) edad yr LED Bing dag vamp pared as LED, Aum Manor anal tr ary ica? Yow ED An tasing an Sa Coc cae Wve contol ex-s02v ‘Selectable positive or negative cont ‘4.202 (1209) ‘CL-E0N (Optional lens for ong range curtain pattern) “Specications and design are subject to change without prot notice. DIMENSIONS Cr reins ree & OPTEX — (DeTEX CO, 1D. S090 aan SORT wrest ue OPTER EUROPE) LTO 09 cama

You might also like