Calculation of prescribed deformation required to creating the hogging bending


moment as per the Fig.3-23.

Geometric Properties

Gross Conc. Trans (n=7.17)

Area (mm 2) x 103 184.3 191.6

Inertia (mm 4) x 106 1883.6 2079.7


75
yt (mm) 340 339
1 - 20 MM
yb (mm) 107 108

447
St (mm 3) x 103
6 MM @ 200 mm
5545.8 6140.6

Sb (mm 3) x 103
2 - 20
17543.4 19199.5
7 - 7 MM
1200
Crack Spacing
2 x dist + 0.1 db /

Loading (N,M,V + dN,dM,dV)


0.0 , 0.0 , 0.0 + 0.0 , 0.01 , 1.0

Concrete Rebar
fc' = 40.0 MPa fu = 550 MPa All dimensions in millimetres
Clear cover to transverse reinforcement = 22 mm
Long, fy= 450
a = 19 mm Links, fy= 250 Corcon 300 mm Rib Beam
ft = 1.97 MPa (auto)

c' = 2.10 mm/m s = 180.0 mm/m Upul Perera 2003/2/27

Load-Max Deflection
54.0
Shear Force (kN)

45.0
36.0
27.0
18.0
9.0 1.7 mm
0.0
0.0 3.0 6.0 9.0 12.0 15.0
Maximum Deflection (mm)

D-1