Professional Documents
Culture Documents
AGA3 Formula
AGA3 Formula
o Calculate = 2
o Calculate = /
o Limit FI to 1000 maximum
Set up coefficient of discharge loop by setting Cd(FT) to Cd0
Perform loop:
o X=FI / Cd(FT)
o IF X < Xc
= 0 + (1 0.35 + 2 + 3 0.8 ) 0.35 + 4 0.8
= (0.71 0.35 + 0.352 + 1.153 0.8 ) 0.35 + 0.84 0.8
o Else:
= 0 + 1 0.7 + (2 + 3 0.8 ) ( ) + 4 0.8
= 0.71 0.7 + (2 + 3 0.8 ) + 3 ( ) 0.8 + 0.84 0.8
Calculate the amount to vary Cd(FT) by:
[ () ]
= =
[1 + ]
()
Change Cd(FT)
() = ()
Loop until dCd is less than 0.000005
Reynold number:
4000
=
Mass flow factor:
= ( ) 2
4
Mass Flow rate:
= () 2