Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Radiography Calculations

Sensitivity & Ug Based on AS2177 - 2006

Ir-192 Exposure Calculator (Fe)

Activity Units* Thickness (mm) Film*


Curie (Ci) 10 D7
1 Ci = 37GBq
Activity SFD (mm)
20 700

Ir-192 Activity

Initial Activity Days of Decay New Activity


50 2 49.1

Wire IQI Sensitivity

Wire Visible* Material Thickness Sensitivity %


16 10 1.00

Geometric Unsharpness Calculator

Method* Source Size (mm) Thickness (mm)


XR 3 , GR 1 & 2 1.5 50

Max Ug Film Offset Note: S and DWS, calculated on Single Wall Thickness.
0.4 0 DWD, Calculated on Outside Diameter.

* = Click For Drop Down Menu


Created By: Paul Grosser
ATTAR IS NOT RESPONSIBLE FOR IMPROPER USE OF THIS DATA
FOR TRAINING USE ONLY
Density* Hours 0
2.5 Minutes 6
Seconds 29
F Factor
1.00 "FFactor" is used to account for variations
in Processing , Screen and Film Combinations

49.0722290847

Note: Single Wall Thickness is to be used for all Sensitivity Calculations

Minimum SFD (mm)


237.5

ulated on Single Wall Thickness.


on Outside Diameter.

Grosser