Test Tips Communication accessories Power Simulator set
- Overvoltage Measurements on several remote locations One phase, multi-purpose power simulator for
category: 1000 V, simultaneously - with a possibility to control Power Quality simulating typical situations in low voltage power
CAT III measuring equipment from a single location - become true
supply systems.
- 4 mm with the following communication equipment.
Excellent tool for training and demonstration
connection. A 1100 - Modem ST purposes.
Typical applications
Simulation of transients, inrush currents, flickers,
4 mm safety connection of the tips makes them
harmonics, power supply outages, etc.
suitable for performing measurements in mains
Load character adjustment, adjustable current and
outlets or quick, indicative voltage measurements.
voltage level with a simulation of 22 different faulty
Availability
conditions.
3 pieces included in a standard set.
Optional: 110 V version.
Dimensions (w x h x l): 265 x 110 x 185 mm.
Voltage measurements cables Mass (without accessories): 2,4 kg.
- Overvoltage category:
1000 V, CAT III
- 4 mm connection. A 1101 - Modem GSM

Typical applications
POWER QUALITY ANALYSIS
Thanks to 4 mm safety connection which fits the
entire range of accessories supplied in the Power
Quality set, the cables can be used in a vast number of
different applications.
Availability
3 pieces included in a Standard set. A 1124 - Modem Entrance Key
Ordering Information
Alligator Clips Typical applications
Standard Set Part No. MI 2191
- Overvoltage Using modem connection between the instrument and
category: 1000 V,
the PC enables the following tasks to be completed:
CAT III - Remote programming of the instrument via PC.
- 4 mm - Downloading recorded data via PC from a remote
location.
connection.
- Receiving SMS alarms (task completed, full memory,
Overvoltage category: 1000 V, CAT III 20 % of memory is free, 50 % of memory is free,
recording is finished).
4 mm connection.
- Clear memory.
Typical applications
Connectivity
Usually used in voltage measurements. They feature
Communication modems come installed on the
firm, reliable grip for safe measurements. instruments and the PC side.
Standardized 4mm safety connection makes them The following combinations are possible:
suitable for use with other instruments. PC side can be equipped either with standard analog
Availability A 1100 Modem ST or with A 1101 Modem GSM.
3 pieces included in a Standard set. The instrument can either have standard analog external
modem A 1100 Modem ST or A 1101 Modem GSM.
- Instrument Power Simulator
A 1171 - Adapter USB / RS232 In case analog phone line is available, A 1100 Modem ST
is used. If not, A 1101 Modem GSM has to be used. - Short form quick guide plastic cards
- RS232 USB Cable Style
A 1124 Modem Entrace Key activates access to the - Power cord
Converter with 1m fixed cable
modem support. - Current measuring cable
- Users manual and Installation
Availability - Instruction manual
guide
- CD Modern Power Quality measurement techniques
- Driver and utility CD - Modems are supplied optionally.
- Declaration of conformity
- A 1124 Modem entrance Key is included in a Standard
Cable can be used to connect instruments with RS232 port - Product verification data
set of MI 2292 Power quality Analyser Plus.
on USB port on PC. Enhanced converter is able to support - A 1124 Modem Entrance Key for MI 2192 and MI 2092
RS232 Baud rates of up to 460k Baud. is available optionally.

Note! Photographs in this catalogue may slightly differ from the instruments at time of delivery.
Subject to technical change without notice.

PowerQ Plus
PowerQ
Power Quality Analyser Plus
Measuring and Regulation
Power Quality Analyser
Equipment Manufacturer d.d.
Ljubljanska 77 Power Harmonics Analyser
SI-1354 Horjul Power Monitor
Tel: + 386 (0)1 75 58 200 VoltScanner
Fax: + 386 (0)1 75 49 226 Power Simulator
E-mail: metrel@metrel.si
http://www.metrel.si
Multifunctional Power Quality Analysers Power Quality Accessories Application Guide
Power Quality Analysis

There are quite a few reasons for measuring and analysing power quality nowadays. Seamless integration of measurement equipment with the analysed object becomes of paramount importance and serves as a great help for
Our work mostly depends on computers and machines supplied by electrical power. technicians on site. Therefore a wide selection of accessories for the entire range of Metrel's digital Power Quality Analysers is available.
Therefore, problems with electrical power - directly impact our work. Recommended use for every product is described in the following guidelines.
What is a power quality problem? This is every deviation of the electricity applied to the More detailed specifications of the products offered can be supplied on request.
equipment which results in damage or misoperation of electronic equipment or other
electrical devices. Current clamps, transformers and Typical applications A 1037 - Three-phase current transformer 5 A/1V
Large capacity measuring head will accommodate
Some common symptoms of power quality problems in facilities are: adapters conductors of various shapes and dimensions.
- Unexplained equipment trips or shutdowns. This range of products extends the versatility of the This set is suitable for 1 or 3-phase current
Power Quality Analyser family and provides safe,
- Occasional equipment damage or component failure. accurate and non-intrusive measurements in
measurements up to 3000 A.
For 3-phase measurements at least 3 pieces of A 1099
- Erratic control of process performance. applications which cannot be accessed with are required.
- Random lockups and data errors. conventional cable connections. With proper connection we can choose between 3-wire
- Power system component overheating. A 1033 - Current Clamps 1000 A / 1 V (3 x A 1099), 4-wire (3 x A 1099) or Aaron (2 x A 1099)
power measurement.
If we look at those technical problems from the economic point of view, this means that Hint Maximum measuring current: 5 A AC
Frequency range: 40 Hz to 5 kHz
we have to deal with: decreased production, time delays, additional expenses and With proper selection of the measuring current range
Voltage output: 200 mV/A
the accuracy can be considerably improved.
company reputation. Therefore good power quality is a must for a normal business flow. Availability Accuracy in %: 0,3 %
Metrel Power Quality Analyser product line will help you find many problems on your Optional. Overvoltage category: 600 V, CAT III
Typical applications
site such as: Measuring range: 0,2 A to 1200 A AC Normally used in power sub-stations with standard
- Identifying sensitive electrical devices. Frequency range: 40 Hz to 5 kHz A 1069 - Mini Clamp 100 A / 1 V with 5 A AC current output.
Typical applications include 3 phase power quality
- Early detection of potential errors. Voltage output: 1 mV/A A 1039 - Clamp Adapter for connection
measurements.
Accuracy in %: 3 at 0.110 A; 3 at 10 A; 2 at 20 A;
- Electrical network optimization or expansion on power quality measurements basis. 1,1 at 200 A; 1 at 1000 A; 1 at 1200 A In case standard current output is present no
Overvoltage category: 600 V, CAT III additional current clamps are needed.
Metrel instruments are easy to use and housed in durable cases, designed for rough Maximum conductor diameter: 51 mm
This set is especially helpful when performing long-
term measurements because there is no need to
environment. They have outstanding price/performance ratio. Maximum aperture: 55 mm
break the electrical circuits.
Typical applications Availability
Designed for use in applications requiring measurement Optional.
Maximum measuring current: 100 A AC
of current without interrupting the electric circuit.
Jaws can be snapped open, placed around the
Frequency range: 40 Hz to 5 kHz Connection cables and adapters
Voltage output: 10 mV/A Introduced range of accessories will safely connect
Typical applications of individual instruments conductor and snapped closed to form a magnetic loop Accuracy in %: 2% at 5 10 A; 1% at 10 100 A the Power Quality Analysers to the measured circuit.
around the conductor. Overvoltage category: 600 V, CAT III Although some of the presented items are not
FLICKER DIAGRAMS STATISTICS REPORTS Hint Maximum conductor diameter: 15 mm included in a standard set they can be ordered
If a clamp is snapped around both wires of a single- Maximum aperture: 15 mm separately when the need occurs.
phase electric network, a leakage current to ground will Typical applications S 2014 Safety Fuse Adapters
be measured. Designed for use in applications requiring measurement
Availability of current without interrupting the electric circuit.
3 pieces are supplied in a standard set. Most frequently used in current and power
A 1120 - Three-phase flex kit 3000 A / 1 V measurements.
Jaw dimensions make them suitable for measurements
on round conductors with a diameter up to 15 mm on
larger single phase systems, telecommunication
applications, switch boxes.
For 3-phase measurements at least two clamps (Aaron Overvoltage category: 600 V, CAT III
Transients capturing with MI 2192 Power Quality Analyzer. Nominal current: 20 A
connection) are required.
Transients can appear due to atmosphere discharges, switching Breaking capacity: 100 kA
Standardized voltage output allows the transformer to
maneuvers or capacitor banks switching. Records can be effectively 4 mm safety connection
be connected to other instruments with 1 V AC input.
used for over voltage protection selection. Note Typical applications
Maximum measuring current: 30 A / 300 A / 3000 A AC Designed for voltage measurements and for
For connecting the current transformer to an instrument
Frequency range: 2 Hz to 5 kHz protection of electrical equipment as well as
Power quality assessment A 1039 Clamp Adapter has to be purchased.
Voltage output: 33,3 mV/A; 3,33 mV/A; 0,33 mV/A electricians in high energy LV systems.
according to EN 50160 and Accuracy: +/- 1% of reading in reference conditions Availability The adapter can be equipped with an efficient low
flicker measurement Overvoltage category: 600 V, CAT III Optional. voltage fuse which reliably isolates the measuring
performed with MI 2292 Length of the measuring head: 450 mm circuit from the mains supply in the event of
Power Quality Analyser Maximum head capacity: 130 mm A 1122 - Mini Clamp 5 A / 1 V with excessively high current load.
Plus. Fuses are not supplied!
A 1039 - Clamp Adapter for connection
Typical applications Availability
Because of their flexibility these current transducers Optional.
will accommodate conductors of various shapes and S 2015 Flat contact Clamps
dimensions. This set is suitable for 3-phase current
Waveform analysis performed either with MI 2192 Power Quality measurements up to 3000 A.
Analyser or MI 2292 Power Quality Analyser Plus. Useful feature Typically used in power quality measurements on
for determining harmonics direction, UPS performance evaluation or larger objects (transformers, sub-stations).
motor's start-up analysis. Hint Maximum measuring current: 5 A AC
With proper selection of the measuring current range Frequency range: 40 Hz to 5 kHz
the accuracy can be considerably improved. Voltage output: 200 mV/A
Availability Accuracy in %: 3% at 0 5 A
Available on request. Overvoltage category: 600 V, CAT III
Maximum conductor diameter: 15 mm Overvoltage category: 600 V, CAT III
Maximum aperture: 15 mm Nominal current: 5 A
A 1099 - Single-phase flex kit 3000 A / 1 V Typical applications Maximum thickness of flat conductor bar: 30 mm
These clamps feature similar properties as the A 1069. 4 mm safety connection
Jaw dimensions make them suitable for measurements Typical applications
on round conductors with a diameter up to 15 mm. Foreseen for voltage measurements. Clamps provide
Nominal current range up to 5 A AC is ideal for reliable grip for safe measurements.
measurements in IT environments, on smaller With adjustable stop they are particularly useful for
electronically regulated loads with high content of making connections on bus bars and other large
Different pre-set loggers within MI 2392 PowerQ Plus allow quick harmonics. sized conductors which cannot be embraced with
Maximum measuring current: 30 A / 300 A / 3000 A AC crocodile clips.
on-site power quality assessment without a need to download Note
Frequency range: 10 Hz to 20 kHz Standardized 4mm safety connection makes them
recorded data on a PC. Examples show phase diagram which helps Periodic measurement of basic power quality parameters (U,I, P, Q, S, For connecting the current transformer to an instrument,
Voltage output: 33.3 mV/A; 3.3 mV/A; 0.33 mV/A suitable for use with other instruments.
when connecting the instrument on power supply network U, I, f PF, etc.) with harmonics analysis performed with MI 2092 Power Accuracy: 1% of range
A 1039 Clamp Adapter has to be purchased.
Availability
logger is a useful feature for measurement conditions evaluation. Harmonics Analyser. Availability
Overvoltage category: 600 V, CAT III Optional.
Optional.
Length of the measuring head: 600 mm - 4 pcs included in a Standard set for MI 2292.
2 Maximum head capacity: 178 mm 11
Power Quality Analysis
Power Quality Analyser-Plus Power Quality Analyser Power Harmonics Analyser Power QPlus Power Q VoltScanner
Main features

Ordering No.: MI 2292 MI 2192 MI 2092 MI 2392 MI 2492 MI 2130


Power Quality Testing
RMS Voltages, Currents (average, min., max.) ( voltage only)
Harmonics Analysis Optional
THD
Power
Active, Reactive, Apparent
Cos j
Character, sign
Voltage Events (dips, sags, interruptions)
Logger (U, I, P, Q, S) Optional
Periodic Analysis
Statistical Analysis
Anomalies (Events) Analysis
VoltScanner Neutral current (calculated)
On line monitoring
Meter mode - tabelaric results
Scope mode - osciloscope
Spectrum Analysis mode Optional
EN 50160 compliant testing
Plug and measure solution to analyse the quality of the line voltage in Fast Set Up - Auto mode
accordance with EN 50160 Technical specification Voltage
Measurement THD & Harmonics
The VoltScanner is a simple instrument designed to record voltage characteristics at the Phase to Neutral Dips, Sags, Interruptions
customers supply terminals in public electricity distribution systems, according to the Range Accuracy Resolution
Flicker
90 to 265 V 2 V of reading + 2 % 1V
EN 50160 standard. Neutral to Ground
Frequency
Range Accuracy Resolution Interharmonics / Signalling
It records voltage dips, swells, transient overvoltages, frequency variations and supply
0 to 155 V 2 V of reading + 2 % 1V Unbalance
interruptions. Frequency EN 50160 Test Report
A flashing LED indicates that events have been captured Range Accuracy Resolution
4752 Hz, 0.1 Hz 0.1 Hz
Special tools
Memory capacity of up to 3500 events 5762 Hz 0.1 Hz 0.1 Hz Fast logging mode (166 minutes) (8,4 minutes)
Transients Waveform mode (7812 periods) (390 periods)
Operating procedure Range Accuracy Resolution Transient mode (1000 periods) (50 periods)
50 to 2600 V 10 % 5V
Set-up limit values Downloading Energy
Minimum width: 1 s
Custom or EN 50160 auto-mode Analysis Total & Subtotal counters
Plug-in - Periodics (max., min., General Other
Nominal Supply Voltage: 230 V or 120 V Optional
Measuring & Recording or average values) - table or graph. PC SW
Nominal Frequency: 50/60 Hz
Events mode Modem entrance key Optional Optional
- Statistics of all the events by character, Communication: RS 232 serial interface,
Dips/Sags, Swells magnitude, time stamp. fully opto isolated, 9 pin D-type connector
Voltage interruptions Memory: 32 kB, 3500 events
Detailed reports and graphs Battery: 6 V DC (4 x 1.5 V AA) Rechargeable Typical application areas Possible corrective solutions Suitable Metrel Power Quality Analyser
Frequency fluctuations Overvoltage category: CAT III 300 V
Transients overvoltage General - General power quality assessment - PF correction equipment - PowerQ Plus MI 2392
Power - Power factor correction - Filters - Power Harmonics Analyser MI 2092
Periodics mode
Ordering information Quality - Harmonics filtering - UPS - Power Quality Analyser MI 2192
Power frequency
Standard Set: Part No. MI 2130 Testing - Power peak reduction - Power conditioners - Power Quality Analyser Plus MI 2292
Supply voltage
- Power breaks capturing
EN 50160 auto-mode

ScanLink EN 50160 - Assessment of supply voltage quality - Dealing with customers complaints - PowerQ Plus MI 2392
ScanLink Windows 95/98/2000/NT Voltage at end users - UPS - Power Quality Analyser MI 2192
software for analysing and print-outs Quality - Assessment of voltage quality at end - Ferro-resonants transformers - Power Quality Analyser Plus MI 2292
with a complete history of captured users - Backup generators - Voltscanner MI 2130 (1-phase only)
Evaluation
events in a tabelaric or graphic form - Assessment of voltage quality in - Power conditioners
(statistics). electrical generation systems
By analysing periodics it enables review - Instrument VoltScanner
- Mains measuring cable, 1.5 m
of voltage quality against the set limits - Battery-rechargeable NiMH 1.2 V, 4 pcs Waveforms - Analysing of influences of motor start-ups - Power Quality Analyser MI 2192
- Voltage regulators
(Custom or EN 50160 auto-mode). - Windows Software "ScanLink - Analysing of load variations
Recording - Power conditioners - Power Quality Analyser Plus MI 2292
Periodics analysis of voltage variation for the past - RS 232 cable - Analysing of non-linear loads - UPS
3 weeks - Instruction Manual
- Declaration of conformity - Ferro-resonant transformers
- Product verification data - Filters

Optional accessories Transients - Analysis of oscillatory transients caused - UPS - Power Quality Analyser MI 2192
S 2010 Capturing by lightning - Overvoltage protection devices - Power Quality Analyser Plus MI 2292
- Analysis of electrostatic discharges - Analysis of switching
- Analysis of switching manouvres manouvres

A 1020 S 1112 A 1171


Fast Logging - Analysing of influences of motor start-ups - Voltage regulators - Power Quality Analyser MI 2192
A 1020 - Small soft carrying bag
Recording - Analysing of load variations - Power conditioners - Power Quality Analyser Plus MI 2292
A 1171 - Adapter USB / RS232
S 1112 - Universal test cable 3 x1.5 m with 3 safety - UPS - PowerQ Plus MI 2392
test tips
10 Set-up of event recording or periodics recording mode Statistics of the captured events S 2010 - Set of Alligator clips(black), 3 pcs 3
Power Quality Analysis

Power Q series (Power QPlus, Power Q) Power Monitor

Advanced, handheld, easy to use 3-phase power quality analysers

Power QPlus and Power Q are genuine, portable 3-phase power quality analysers which favorably compete Power Monitor MI 4100 is a multifunction instrument, which Suitable for:
with higher priced instruments and can be easily implemented in a variety of different situations. performs accurate single or three phase simultaneous Monitoring electrical equipment susceptible to power
Power QPlus and Power Q are due to their small dimensions and ease of use ideally suited for routine or measurements of: quality.
complex power quality assessment in heavy duty industrial environments. rms voltage, Monitoring critical electrical equipment which can
rms current, compromise power quality and cause malfunction of
Pre-set logging screens allow on-site evaluation of all major power quality parameters (U,I, P, PF, cos j, THD,
harmonic analysis (up to 31st harmonic component), sensitive devices.
individual harmonics components, phase shifts, etc.).
power and crest factor, Power on demand: connecting and disconnecting loads,
Windows compatible PowerQ Link software package expands the versatility of Power QPlus and allows power (4-quadrant) energy, taking into account current power consumption. Reducing
transfer of stored data to a computer. energy (active and reactive). peak power consumption by means of disconnecting
Power QPlus and Power Q can be manipulated by one hand, leaving the other hand free for tools. It is equipped with storage memory, 4 opto-isolated inputs and 2 unnecessary loads.
Voltage harmonics programmable relay outputs. RS-485 and MODBUS interface Distributed measuring systems, connected via ModBus
Measuring range: UM > 3 %UN permit remote reading and control. Due to its compact design protocol with central data system.
- Resolution: 0.1 %
Target applications and high interference resistance it is suitable for fixed mounting All in one replacement for more than 12 classical
- Accuracy: 5 % UM (3 % for DC)
Power quality assessment and troubleshooting in low voltage electrical systems. Measuring range: UM < 3 %UN and continuous non supervised operation. instruments (voltmeters, ampermeters, cos j meters, etc.).
Balancing phase currents in 3-phase systems. - Resolution: 0.1 %
- Accuracy: 0.15 % UN
Checking power correction equipment performance. UN: nominal voltage (TRMS)
x A/5 A
L1
Harmonics spectrum analysis for selection of harmonic filters. UM: measured harmonic voltage hM = 1st 50th x A/5 A
L3
Capturing inrush currents e.g. motor's start up currents. x A/5 A
L3
Current harmonics
Voltage deviations recording. Measuring range: IM > 3 %IN
Consumption recording. - Resolution: 0.1 % N
- Accuracy: 5 % IM (3 % for DC)
Main features Measuring range: IM < 3 %IN
- Resolution: 0.1 % 1............................30
Simultaneous analysis of basic power quality - Accuracy: 0.15 % IN
parameters (U,I,P,Q,S, PF). Power Q IN: nominal range (TRMS)
25 V/0,5 A

Harmonics analysis up to 50th component. Simplified version of Power QPlus IM: measured harmonic current hM = 1st 50th

Phase diagram. with all basic measurement Loggers


Voltage unbalance calculation for 3-phase systems. functions. Voltage and current logger
On-line scope function. Compatible user interface, Signals: selectable U1, U2, U3, I1, I2, I3 COM
INPUT 1
Interval: selectable (1, 2, 5, 10,15, 30) seconds RS 485 INPUT 2

Lightweight design. manipulation and software with or (1, 2, 5, 10, 15, 30) minutes
INPUT 3
INPUT 4

Downloading software package PowerQ Link. Power QPlus. Displayed data: min., average and max. value of RS 232/USB/RS 485 OUTPUT 1

the interval OUTPUT 2

Power logger
Signals: selectable L1, L2, L3, TOT
Interval: selectable (1, 2, 5, 10, 15, 30) seconds
or (1, 2, 5, 10, 15, 30) minutes
Displayed data: min., average and max. value of
Technical specification - Power QPlus the interval (for all four quadrants) Technical specifications Ordering information
Voltage Power Harmonics logger Configuration: 3 voltage inputs, 3 current inputs General specification Standard Set: Part No. MI 4100
Three-phase AC voltage input Measured parameters: Signals: selectable THDI1, THDI2, System: single phase, 3-phase Power supply voltage: 180 V a.c. 260 V a.c.), - Instrument Power Monitor
(3 differential inputs, L1-N, L2-N, L3-N) - Active power (P) THDI3, THDU1, THDU2, THDU3, (3 or 4 wire unbalanced load) 50 Hz/60 Hz - Instruction manual
Input voltage range: 3 - 550 VRMS L-N - Reactive power (Q) Interval: selectable (1, 2, 5, 10, 15, 30) Measuring principle: 4 quadrants, 10 periods, 128 scans/period Protection classification: double insulation - Product verification data
3 - 550 VRMS L-L - Apparent power (S) seconds or (1, 2, 5, 10, 15, 30) Display update: 1 update/s, harmonics 1 update/5 s Pollution degree: 3 - Declaration of conformity
Resolution: 0.1 V - Power factor minutes Direct connection of current inputs to standard CTs with 5 A output Protection degree: IP 40
Crest factor: 1...1.4 (1.4 @ 550 VRMS L-N) - Cos j Displayed data: min., average and max. value of Wide voltage range from 0 V to 500 V Overvoltage category: CAT II 600 V/CAT III 300 V
Frequency range: 45 66 Hz - Energy (kWh, vah, varh) the interval Backlit LCD with 4 x 20 characters Load: 5 VA max.
Current Accuracy: Inrushes 42 days of active and reactive energy logging Dimensions (w h d): 96 mm 96 mm 100 mm
Three-phase AC input for connection to current - Power: (3 % + 3 dig) Signals: selectable U1, U2, U3, I1, I2, I3 RS 485 communication port Standards applied: EN61010-1, EN 61326
transducers with voltage output. - Power factor: Interval: selectable, (10, 20, 100, 200) ms
Range 1: 0.004 VRMS 0.1 VRMS (4 A 100 A) Range 1: 0.00 0.39; Accuracy 0.06 Trigger channels: I1, I2, I3
Resolution: 0.1 A Range 2: 0.40 1.00; Accuracy 0.03 Trigger level: electable, 2 % 100 % of current
Crest factor: 1... 2.3 @ 0.1 VRMS All measurements are performed in four quadrants: load range (in steps of 0.1 % of
Range 2: 0.04 VRMS 1 VRMS (40 A 1000 A) or generator with capacitive or inductive character. current range)
Resolution: 0.1 A Displayed data: min., average and max. value of
4 Crest factor: 1... 2.3 @ 0.1 VRMS the interval 9
Connection to the Power Systems
Power Quality Analysis

PowerLink Recorder mode


Simple set-up
Selection of signals and type of L1

SOURCE
I1 I2 I3
analysis (periodics, anomalies,

LOAD
statistics, EN 50160). L2 power plant
L1
N

L2 L3
measuring instruments
Selection of recording time and L3
averaging cycles integration A A A
period. N
Recording can be set also directly
from the instrument.

4W
Analysis
Direct mode PERIODICS AND STATISTICS ANALYSIS
high
voltage
On-line monitoring of three-phase Over 300 quantities (64 simultaneously) can be recorded xA / 5A
L1
currents and voltages and stored in this mode. All important quantities and
xA / 5A
6-CHANNEL OSCILLOSCOPE events can be selected: L2
L3 xA / 5A
average, minimum and maximum voltage
and current RMS values,
harmonics and THD of voltage and current, 3-phase 4-wire system (with neutral conductor) Connecting instrument to the existing current transformers in high
particular and total power voltage system
(classified sign and character),
voltage events and anomalies
(interruptions, dips, sags), type and duration,
flicker Pst and Plt values,
other EN50160 parameters: signaling, Ordering information
interharmonics, unbalances. Standard Set Part No. MI 2392
HARMONICS UP TO 63rd

EN 50160 AUTO-MODE with statistics and results based on the standard


HARMONICS REPORT

STATISTICS REPORT
in EN 50160 graphic and tabelaric form
FLICKER DIAGRAMS

Phase diagram PowerQPlus enables on-screen evaluation of


various pre-set loggers. This is an example of a
logger for U, I.
- Instrument PowerQPlus, PowerQ
- Current clamp 1000A/1V, 3 pcs
Test Reports Saving results, graphs and reports for further analysis - Test tips, 3 pcs
Exporting data and graphs in xls files for making custom reports. - Alligator clips, 4 pcs
Printing out results and graphs. - Voltage measurement cables, 4 pcs
- PC SW Package PowerQ Link on CD with RS 232
cable
PC Software - Power supply adapter
Special tools enable a detailed, time domain based signal analysis. They represent a powerful, modern troubleshooting tool for solving all - Rechargeable batteries, 6pcs
- Soft carrying bag
kinds of problems which appear in power distribution systems. The user can choose between three modes, differing in terms of sampling
- User manual
speed, trigger possibilities and recording time: - Product verification data
- Declaration of conformity

WAVEFORMS
Recording voltages and currents with 128 samples/period. Half Optional accessories
period RMS values of recorded quantities are also calculated and UIf scoope screen Power logger motor screen
shown in this mode. Best suited for:
monitoring switching phenomena,
Accuracy General technical specification
locating noise and disturbance sources,
Voltage Working temperature range: -10 C +55 C
defining disturbance type, A 1069, A 1122
Measuring range Accuracy Max. Humidity: 95 % RH (0 C 40 C),
locating excessive harmonics sources. non-condensing
A 1020 A 1037
Range 1: 3.0 VRMS 70.0 VRMS (1 % + 0.5 V)
Range 2: 5.0 VRMS 130.0 VRMS (1 % + 0.8 V) Pollution degree: 2
Range 3: 10.0 VRMS 300.0 VRMS (1 % + 1.5 V) Protection classification: double insulation
Range 4: 20.0 VRMS 550.0 VRMS (1 % + 2.5 V) Overvoltage category: voltage inputs: CAT III 600 V
FAST LOGGING OF SIGNALS Current Protection degree: IP 42
Recording half period RMS voltage and current values. Measuring rangeResolutionAccuracy Display: graphic liquid crystal display A 1120 S 2014 S 2015
Recommended when record length is critical and signals Range 1: 0.004 VRMS 0.1 VRMS (2 % + 0.3 A) with backlight, 160x160 dots
Range 2: 0.04 VRMS 1 VRMS (2 % + 3 A) External DC supply: 12 V, 400 mA min.
details are not of importance. Best suited for:
Voltage events Maximum power consumption: 360 mA
observing start up and inrush events,
Signals: selectable U1, U2, U3 Communication: RS 232 serial interface
locating impedance problems, and USB A 1039
Swell limit: (1 % 35 %) UN
long term analysing of unstable mains. Dip limit: (-35 % -1 %) UN Baud rate: 2400 bps 115200 bps A 1099 A 1171
Interruption limit: (1 % 20 %) UN Connector: 9 pin D-type and USB-B A 1020 - Small soft carrying bag
Logging time: manual stop, (1, 2, 5, 10, 30) minutes Dimensions: (220 x 115 x 90) mm A 1037 - Current transformer 5 A/1 V
or (1, 2, 5, 10, 30, 50, 75) hours Weight (without accessories): 0.65 kg A 1039 - Clamp adapter
TRANSIENTS Hysteresis: 1 %UN A 1069 - Mini clamp 100 A / 1 V
The recording mode with fastest sampling rate the instrument can Signals A 1099 - Current clamp 3000 A / 1 V
provide. Up to 50 kHz transient detect ability in this mode. Best suited Measuring range Accuracy A 1120 - 3-phase flex-kit, 45 cm, 3000 A / 1 V
for: Range 1: 5.0 VRMS 70.0 VRMS (5 % + 1 V) A 1122 - Mini clamp 5 A /1 V
monitoring atmospheric discharging, Range 2: 10.0 VRMS 130.0 VRMS (5 % + 1.5 V) A 1171 - Adapter USB / RS232
analysing switching problems, Range 3: 20.0 VRMS 300.0 VRMS (5 % + 3 V) S 2014 - Safety fuse adapters
detailed analysis of high frequency noise and notching. Range 4: 30.0 VRMS 550.0 VRMS (5 % + 5 V) S 2015 - Safety flat clamps
Logger lengths depend on selected interval.
8 Maximum recording time is displayed automatically. 5
Ordering information
Standard Set Part No. MI 2292
Power Quality Analysis

- Instrument Power Quality Analyser


- Current clamp 1000 A/1V, 3pcs
- Smal soft carrying bag for current clamps
- Test tip, red; 3 pcs
- Safety flat clamp, 4 pcs

Power Harmonics Analyser - Alligator clip, black; 4pcs


- Voltage measurement cables; 6 pcs
- Mains cable
Power Quality Analyser Plus Power Quality Analyser - RS 232 cable
- 4 1,2 V NiMH batteries
- Power Link PC analysis and control SW package
- Soft carrying bag
- Instruction manual
- Declaration of conformity
- Product verification data
- CD Modern Power Quality measurement techniques
Power Quality Analyser Plus Power Quality Analyser Power Harmonics Analyser Standard Set Part No. MI 2092
MI 2292 MI 2192 MI 2092 Standard Set Part No. MI 2192
- Standard Set Part No. MI 2292
Metrels top of the range three- Three-phase, multifunction Three-phase, multifunction power (without safety flat clamp S 2015)
phase, multifunction power instrument with all the necessary quality analyser suitable for Optional accessories
quality analyser with a complete functions to perform a complete performing all the most frequent
selection of test functions and measurement and diagnostics of measurements and diagnostics in
diagnostics tools for wide range power quality. different electrical systems.
Automatic EN 50160 power quality Accurate Energy Measurement Voltage and Current True Real Time operation
of applications. Optional remote modem A 1037 A 1099 A 1069, A 1122
Active & Reactive Harmonic Analysis up to for voltage interrupts and
Automatic EN 50160 power assessment test. communication support. Import & Export rd
power break capturing
63 component
quality assessment test. Recording of short-period events like Optional: 110 V version. Inductive & Capacitive. 2 MB of memory allow data
Flicker measurement in transients, inrush currents, resonant Separate registers for Total, logging up to several months.
accordance with EN 50160. states, switchings, etc. Sub-total & Last Integration
Period A 1120 A 1100 A 1101
Modem communication support Harmonics direction determination.
for remote control of the Optional remote modem
instrument. communication support.
Measurements according to IEC / Optional: 110 V version.
EN 61000-4-30. A 1039 A 1171 S 2014 S 2015
Recording of short-period events like A 1037 - Current transformer 5 A/1 V
transients, inrush currents, resonant A 1039 - Clamp adapter
A 1069 - Mini clamp 100 A / 1 V
states, switchings, etc.
Modem Remote Control Waveform analysis Scope function allows Configuration menu A 1099 - Current clamp 3000 A / 1 V
Harmonics direction determination. by using GSM or standard monitoring of current and for setting measuring method, A 1100 - Modem ST
Optional: 110 V version. type of telephone voltage integration period, current A 1101 - Modem GSM
communication. scaling factor and selection of A 1120 - 3-phase flex-kit, 45 cm, 3000 A/1 V
A 1122 - Mini clamp 5 A /1 V
signals.
A 1124 - Modem Entrance Key (MI 2092, MI 2192)
A 1171 - Adapter USB / RS232
Technical specification S 2014 - Safety fuse adapters
AC VOLTAGES METER Power measurement RECORDER S 2015 - Safety flat clamps (MI 2092, MI 2192)
Three-phase AC voltage input (3 differential inputs, L1 - N1, L2 - N2, L3 - N3) Quantities related to selected measuring connections per phase, i.e.: Periodics integration period: 1 s 900 s
Input voltage range: 10550 Vrms L-N, 900 Vrms L-L Measured: voltage (U), current (I), cosj between U and I Selected signals: max. 64 General specification
600 Vrms L-N (over load 10 s) Calculated: active power (P), apparent power (S), reactive power (Q), Statistics values: each period divided in 200 parts (0.1 ms) Display: Graphic Liquid Crystal Display with LED backlight, 160 x 116 dots resolution
Optional on request: 10750 Vrms L-N, 1000 Vrms L-L power factor (Pf) with its characteristics (c, I, none) Voltage anomalies: based on half period, start, duration and extremes of voltage NON VOLATILE MEMORY
800 Vrms L-N (overload 10 s) Line Line voltage; EN 50160 ANALYSIS MODE (MI 2292 and MI 2192) 2048 Kbytes SRAM, battery backed.
Resolution: 0.1 V Quantities for complete three-phase system, i.e.: Voltage dips, swells, sags and breaks, resolution 10 ms, no gaps DIGITAL HARDWARE SPECIFICATION
Accuracy: 0.5 % of reading 2 digits Calculated: active power (Pt), apparent power (St), reactive power Voltage unsimetry, Voltage RMS values, Frequency A/D conversion, 14 bit with 128 samples per channel per period (4368 Hz).
Crest factor max. 1...1.4 @ 550 Vrms L-N (Qt), power factor (Pft), neutral current (In); Harmonics: up to 43rd component OUTPUTS
Frequency range: 4368 Hz fundamental Basic accuracy for P, Q, S,: 1 % of reading Flickers Plt Pst: no gap Communication type: RS 232 serial interface, fully opto isolated
AC CURRENTS Resolution for P, Q, S,: 0.01 of displayed value FLICKER MEASUREMENT Baud rate: 240057600 bps
Three-phase AC input for connection to current transducers with voltage output SPECTRUM Harmonics measurement The instrument computes flickers according to IEC 61000-4-15 (MI 2292 only) Connector: 9 pin D-type.
Input current (voltage range): 0.021 Vrms (from 0.02 x In to In) input The instrument computes harmonics on signals sampled with an A/D converter. WAVEFORMS Communication cable: Standard type
Resolution: 0.3 mV (0.3 A with 1000 A / 1 V) Recording interval: 160 ms (8 cycles) Sampling rate: 128 scans / period (MI 2292 - 7812 periods, MI 2192 - 390 periods) POWER SUPPLY
Accuracy: 0.5 % of reading 6 digits plus current transformer accuracy Spectrum calculation range: DC 63rd Trigger: level, manual, timer Operating range: 230 V A.C. + 10 % 20 %, 4565 Hz, 8 VA
Crest factor: 1...2.5 @ 1 VRMS Spectrum display range: DC 25th Buffer: min. 10 periods of pre / post size, up to 7812 periods can be recorded Optional: 115 V A.C. +10 % 20 %, 4565 Hz, 8 VA
Maximum permissible overload: 150 % In (sinusoidal current) Displayed items for selected harmonic: Order, relative and absolute value Channels: 3 x U, 3 X I, U lines, Min / Max rms values: Avg DC power supply: Internal 4 x 1.2 V NiCd or NiMh rechargeable IEC LR14
Maximum input voltage: 1 Vrms Range Limits of error Resolution Pf, cosj, Crest factor, THD U, I Frequency batteries provide full operation for up to 5 hours.
PHASE ANGLE Irange Urange THD Total Harmonic HD Harmonic on LCD and PC Harmonics / direction: magnitudes / positive / negative Charger: Internal built-in battery charger, charging time approx. 10 hours.
Consider phase angle data of current transformer used. Distortion Distortion FAST LOGGING GENERAL
SCOPE 2 100 % 0.2 % x Ur/U (Ir/I ) 0.2 % x Ur/U (Ir/I) 0.1 % Sampling rate: 128 scans / period, min, max, avg recorded each half period Working temperature range: 20 C + 60 C
Display options Waveform of pairs (L1: U1 and I1, L2: U2 and I2, ENERGY Trigger: level, manual, timer Max. humidity: 85 % RH (0 40 C)
L3: U3 and I3), U1, 2, 3, and I1, 2, 3 Displayed quantities from integration of calculated power as: Buffer: pre / post size, up to 166 minutes of recording Pollution degree: 2
Ranging Auto / manual cumulative values (TOTAL); Channels: 3 x U, 3 X I, Single or multi channel mode Protection classification: II - double insulation
partly cumulative (resettable by user request) (SUBTOTAL); TRANSIENTS Overvoltage category: Voltage inputs: CAT III 600 V; optional CAT IV 600 V
values related to last integration period (LAST IP). Capturing: >20 s transient detect ability AC power supply CAT III 300 V
Quantities. Active energy (EP), capacitive energy (EQC), inductive energy (EQI) Trigger: Level, slope, manual Protection degree: IP 64
Basic accuracy: 1 % of reading Buffer: min. 10 periods of pre / post size, up to 1000 periods can be recorded Dimensions: 265 x 110 x 185 mm
6 Resolution: 0.1 of displayed value Channels: 3 x U, 3 X I, single or multi channel mode Weight (without accessories): 2 kg 7
Ordering information
Standard Set Part No. MI 2292
Power Quality Analysis

- Instrument Power Quality Analyser


- Current clamp 1000 A/1V, 3pcs
- Smal soft carrying bag for current clamps
- Test tip, red; 3 pcs
- Safety flat clamp, 4 pcs

Power Harmonics Analyser - Alligator clip, black; 4pcs


- Voltage measurement cables; 6 pcs
- Mains cable
Power Quality Analyser Plus Power Quality Analyser - RS 232 cable
- 4 1,2 V NiMH batteries
- Power Link PC analysis and control SW package
- Soft carrying bag
- Instruction manual
- Declaration of conformity
- Product verification data
- CD Modern Power Quality measurement techniques
Power Quality Analyser Plus Power Quality Analyser Power Harmonics Analyser Standard Set Part No. MI 2092
MI 2292 MI 2192 MI 2092 Standard Set Part No. MI 2192
- Standard Set Part No. MI 2292
Metrels top of the range three- Three-phase, multifunction Three-phase, multifunction power (without safety flat clamp S 2015)
phase, multifunction power instrument with all the necessary quality analyser suitable for Optional accessories
quality analyser with a complete functions to perform a complete performing all the most frequent
selection of test functions and measurement and diagnostics of measurements and diagnostics in
diagnostics tools for wide range power quality. different electrical systems.
Automatic EN 50160 power quality Accurate Energy Measurement Voltage and Current True Real Time operation
of applications. Optional remote modem A 1037 A 1099 A 1069, A 1122
Active & Reactive Harmonic Analysis up to for voltage interrupts and
Automatic EN 50160 power assessment test. communication support. Import & Export rd
power break capturing
63 component
quality assessment test. Recording of short-period events like Optional: 110 V version. Inductive & Capacitive. 2 MB of memory allow data
Flicker measurement in transients, inrush currents, resonant Separate registers for Total, logging up to several months.
accordance with EN 50160. states, switchings, etc. Sub-total & Last Integration
Period A 1120 A 1100 A 1101
Modem communication support Harmonics direction determination.
for remote control of the Optional remote modem
instrument. communication support.
Measurements according to IEC / Optional: 110 V version.
EN 61000-4-30. A 1039 A 1171 S 2014 S 2015
Recording of short-period events like A 1037 - Current transformer 5 A/1 V
transients, inrush currents, resonant A 1039 - Clamp adapter
A 1069 - Mini clamp 100 A / 1 V
states, switchings, etc.
Modem Remote Control Waveform analysis Scope function allows Configuration menu A 1099 - Current clamp 3000 A / 1 V
Harmonics direction determination. by using GSM or standard monitoring of current and for setting measuring method, A 1100 - Modem ST
Optional: 110 V version. type of telephone voltage integration period, current A 1101 - Modem GSM
communication. scaling factor and selection of A 1120 - 3-phase flex-kit, 45 cm, 3000 A/1 V
A 1122 - Mini clamp 5 A /1 V
signals.
A 1124 - Modem Entrance Key (MI 2092, MI 2192)
A 1171 - Adapter USB / RS232
Technical specification S 2014 - Safety fuse adapters
AC VOLTAGES METER Power measurement RECORDER S 2015 - Safety flat clamps (MI 2092, MI 2192)
Three-phase AC voltage input (3 differential inputs, L1 - N1, L2 - N2, L3 - N3) Quantities related to selected measuring connections per phase, i.e.: Periodics integration period: 1 s 900 s
Input voltage range: 10550 Vrms L-N, 900 Vrms L-L Measured: voltage (U), current (I), cosj between U and I Selected signals: max. 64 General specification
600 Vrms L-N (over load 10 s) Calculated: active power (P), apparent power (S), reactive power (Q), Statistics values: each period divided in 200 parts (0.1 ms) Display: Graphic Liquid Crystal Display with LED backlight, 160 x 116 dots resolution
Optional on request: 10750 Vrms L-N, 1000 Vrms L-L power factor (Pf) with its characteristics (c, I, none) Voltage anomalies: based on half period, start, duration and extremes of voltage NON VOLATILE MEMORY
800 Vrms L-N (overload 10 s) Line Line voltage; EN 50160 ANALYSIS MODE (MI 2292 and MI 2192) 2048 Kbytes SRAM, battery backed.
Resolution: 0.1 V Quantities for complete three-phase system, i.e.: Voltage dips, swells, sags and breaks, resolution 10 ms, no gaps DIGITAL HARDWARE SPECIFICATION
Accuracy: 0.5 % of reading 2 digits Calculated: active power (Pt), apparent power (St), reactive power Voltage unsimetry, Voltage RMS values, Frequency A/D conversion, 14 bit with 128 samples per channel per period (4368 Hz).
Crest factor max. 1...1.4 @ 550 Vrms L-N (Qt), power factor (Pft), neutral current (In); Harmonics: up to 43rd component OUTPUTS
Frequency range: 4368 Hz fundamental Basic accuracy for P, Q, S,: 1 % of reading Flickers Plt Pst: no gap Communication type: RS 232 serial interface, fully opto isolated
AC CURRENTS Resolution for P, Q, S,: 0.01 of displayed value FLICKER MEASUREMENT Baud rate: 240057600 bps
Three-phase AC input for connection to current transducers with voltage output SPECTRUM Harmonics measurement The instrument computes flickers according to IEC 61000-4-15 (MI 2292 only) Connector: 9 pin D-type.
Input current (voltage range): 0.021 Vrms (from 0.02 x In to In) input The instrument computes harmonics on signals sampled with an A/D converter. WAVEFORMS Communication cable: Standard type
Resolution: 0.3 mV (0.3 A with 1000 A / 1 V) Recording interval: 160 ms (8 cycles) Sampling rate: 128 scans / period (MI 2292 - 7812 periods, MI 2192 - 390 periods) POWER SUPPLY
Accuracy: 0.5 % of reading 6 digits plus current transformer accuracy Spectrum calculation range: DC 63rd Trigger: level, manual, timer Operating range: 230 V A.C. + 10 % 20 %, 4565 Hz, 8 VA
Crest factor: 1...2.5 @ 1 VRMS Spectrum display range: DC 25th Buffer: min. 10 periods of pre / post size, up to 7812 periods can be recorded Optional: 115 V A.C. +10 % 20 %, 4565 Hz, 8 VA
Maximum permissible overload: 150 % In (sinusoidal current) Displayed items for selected harmonic: Order, relative and absolute value Channels: 3 x U, 3 X I, U lines, Min / Max rms values: Avg DC power supply: Internal 4 x 1.2 V NiCd or NiMh rechargeable IEC LR14
Maximum input voltage: 1 Vrms Range Limits of error Resolution Pf, cosj, Crest factor, THD U, I Frequency batteries provide full operation for up to 5 hours.
PHASE ANGLE Irange Urange THD Total Harmonic HD Harmonic on LCD and PC Harmonics / direction: magnitudes / positive / negative Charger: Internal built-in battery charger, charging time approx. 10 hours.
Consider phase angle data of current transformer used. Distortion Distortion FAST LOGGING GENERAL
SCOPE 2 100 % 0.2 % x Ur/U (Ir/I ) 0.2 % x Ur/U (Ir/I) 0.1 % Sampling rate: 128 scans / period, min, max, avg recorded each half period Working temperature range: 20 C + 60 C
Display options Waveform of pairs (L1: U1 and I1, L2: U2 and I2, ENERGY Trigger: level, manual, timer Max. humidity: 85 % RH (0 40 C)
L3: U3 and I3), U1, 2, 3, and I1, 2, 3 Displayed quantities from integration of calculated power as: Buffer: pre / post size, up to 166 minutes of recording Pollution degree: 2
Ranging Auto / manual cumulative values (TOTAL); Channels: 3 x U, 3 X I, Single or multi channel mode Protection classification: II - double insulation
partly cumulative (resettable by user request) (SUBTOTAL); TRANSIENTS Overvoltage category: Voltage inputs: CAT III 600 V; optional CAT IV 600 V
values related to last integration period (LAST IP). Capturing: >20 s transient detect ability AC power supply CAT III 300 V
Quantities. Active energy (EP), capacitive energy (EQC), inductive energy (EQI) Trigger: Level, slope, manual Protection degree: IP 64
Basic accuracy: 1 % of reading Buffer: min. 10 periods of pre / post size, up to 1000 periods can be recorded Dimensions: 265 x 110 x 185 mm
6 Resolution: 0.1 of displayed value Channels: 3 x U, 3 X I, single or multi channel mode Weight (without accessories): 2 kg 7
Connection to the Power Systems
Power Quality Analysis

PowerLink Recorder mode


Simple set-up
Selection of signals and type of L1

SOURCE
I1 I2 I3
analysis (periodics, anomalies,

LOAD
statistics, EN 50160). L2 power plant
L1
N

L2 L3
measuring instruments
Selection of recording time and L3
averaging cycles integration A A A
period. N
Recording can be set also directly
from the instrument.

4W
Analysis
Direct mode PERIODICS AND STATISTICS ANALYSIS
high
voltage
On-line monitoring of three-phase Over 300 quantities (64 simultaneously) can be recorded xA / 5A
L1
currents and voltages and stored in this mode. All important quantities and
xA / 5A
6-CHANNEL OSCILLOSCOPE events can be selected: L2
L3 xA / 5A
average, minimum and maximum voltage
and current RMS values,
harmonics and THD of voltage and current, 3-phase 4-wire system (with neutral conductor) Connecting instrument to the existing current transformers in high
particular and total power voltage system
(classified sign and character),
voltage events and anomalies
(interruptions, dips, sags), type and duration,
flicker Pst and Plt values,
other EN50160 parameters: signaling, Ordering information
interharmonics, unbalances. Standard Set Part No. MI 2392
HARMONICS UP TO 63rd

EN 50160 AUTO-MODE with statistics and results based on the standard


HARMONICS REPORT

STATISTICS REPORT
in EN 50160 graphic and tabelaric form
FLICKER DIAGRAMS

Phase diagram PowerQPlus enables on-screen evaluation of


various pre-set loggers. This is an example of a
logger for U, I.
- Instrument PowerQPlus, PowerQ
- Current clamp 1000A/1V, 3 pcs
Test Reports Saving results, graphs and reports for further analysis - Test tips, 3 pcs
Exporting data and graphs in xls files for making custom reports. - Alligator clips, 4 pcs
Printing out results and graphs. - Voltage measurement cables, 4 pcs
- PC SW Package PowerQ Link on CD with RS 232
cable
PC Software - Power supply adapter
Special tools enable a detailed, time domain based signal analysis. They represent a powerful, modern troubleshooting tool for solving all - Rechargeable batteries, 6pcs
- Soft carrying bag
kinds of problems which appear in power distribution systems. The user can choose between three modes, differing in terms of sampling
- User manual
speed, trigger possibilities and recording time: - Product verification data
- Declaration of conformity

WAVEFORMS
Recording voltages and currents with 128 samples/period. Half Optional accessories
period RMS values of recorded quantities are also calculated and UIf scoope screen Power logger motor screen
shown in this mode. Best suited for:
monitoring switching phenomena,
Accuracy General technical specification
locating noise and disturbance sources,
Voltage Working temperature range: -10 C +55 C
defining disturbance type, A 1069, A 1122
Measuring range Accuracy Max. Humidity: 95 % RH (0 C 40 C),
locating excessive harmonics sources. non-condensing
A 1020 A 1037
Range 1: 3.0 VRMS 70.0 VRMS (1 % + 0.5 V)
Range 2: 5.0 VRMS 130.0 VRMS (1 % + 0.8 V) Pollution degree: 2
Range 3: 10.0 VRMS 300.0 VRMS (1 % + 1.5 V) Protection classification: double insulation
Range 4: 20.0 VRMS 550.0 VRMS (1 % + 2.5 V) Overvoltage category: voltage inputs: CAT III 600 V
FAST LOGGING OF SIGNALS Current Protection degree: IP 42
Recording half period RMS voltage and current values. Measuring rangeResolutionAccuracy Display: graphic liquid crystal display A 1120 S 2014 S 2015
Recommended when record length is critical and signals Range 1: 0.004 VRMS 0.1 VRMS (2 % + 0.3 A) with backlight, 160x160 dots
Range 2: 0.04 VRMS 1 VRMS (2 % + 3 A) External DC supply: 12 V, 400 mA min.
details are not of importance. Best suited for:
Voltage events Maximum power consumption: 360 mA
observing start up and inrush events,
Signals: selectable U1, U2, U3 Communication: RS 232 serial interface
locating impedance problems, and USB A 1039
Swell limit: (1 % 35 %) UN
long term analysing of unstable mains. Dip limit: (-35 % -1 %) UN Baud rate: 2400 bps 115200 bps A 1099 A 1171
Interruption limit: (1 % 20 %) UN Connector: 9 pin D-type and USB-B A 1020 - Small soft carrying bag
Logging time: manual stop, (1, 2, 5, 10, 30) minutes Dimensions: (220 x 115 x 90) mm A 1037 - Current transformer 5 A/1 V
or (1, 2, 5, 10, 30, 50, 75) hours Weight (without accessories): 0.65 kg A 1039 - Clamp adapter
TRANSIENTS Hysteresis: 1 %UN A 1069 - Mini clamp 100 A / 1 V
The recording mode with fastest sampling rate the instrument can Signals A 1099 - Current clamp 3000 A / 1 V
provide. Up to 50 kHz transient detect ability in this mode. Best suited Measuring range Accuracy A 1120 - 3-phase flex-kit, 45 cm, 3000 A / 1 V
for: Range 1: 5.0 VRMS 70.0 VRMS (5 % + 1 V) A 1122 - Mini clamp 5 A /1 V
monitoring atmospheric discharging, Range 2: 10.0 VRMS 130.0 VRMS (5 % + 1.5 V) A 1171 - Adapter USB / RS232
analysing switching problems, Range 3: 20.0 VRMS 300.0 VRMS (5 % + 3 V) S 2014 - Safety fuse adapters
detailed analysis of high frequency noise and notching. Range 4: 30.0 VRMS 550.0 VRMS (5 % + 5 V) S 2015 - Safety flat clamps
Logger lengths depend on selected interval.
8 Maximum recording time is displayed automatically. 5
Power Quality Analysis

Power Q series (Power QPlus, Power Q) Power Monitor

Advanced, handheld, easy to use 3-phase power quality analysers

Power QPlus and Power Q are genuine, portable 3-phase power quality analysers which favorably compete Power Monitor MI 4100 is a multifunction instrument, which Suitable for:
with higher priced instruments and can be easily implemented in a variety of different situations. performs accurate single or three phase simultaneous Monitoring electrical equipment susceptible to power
Power QPlus and Power Q are due to their small dimensions and ease of use ideally suited for routine or measurements of: quality.
complex power quality assessment in heavy duty industrial environments. rms voltage, Monitoring critical electrical equipment which can
rms current, compromise power quality and cause malfunction of
Pre-set logging screens allow on-site evaluation of all major power quality parameters (U,I, P, PF, cos j, THD,
harmonic analysis (up to 31st harmonic component), sensitive devices.
individual harmonics components, phase shifts, etc.).
power and crest factor, Power on demand: connecting and disconnecting loads,
Windows compatible PowerQ Link software package expands the versatility of Power QPlus and allows power (4-quadrant) energy, taking into account current power consumption. Reducing
transfer of stored data to a computer. energy (active and reactive). peak power consumption by means of disconnecting
Power QPlus and Power Q can be manipulated by one hand, leaving the other hand free for tools. It is equipped with storage memory, 4 opto-isolated inputs and 2 unnecessary loads.
Voltage harmonics programmable relay outputs. RS-485 and MODBUS interface Distributed measuring systems, connected via ModBus
Measuring range: UM > 3 %UN permit remote reading and control. Due to its compact design protocol with central data system.
- Resolution: 0.1 %
Target applications and high interference resistance it is suitable for fixed mounting All in one replacement for more than 12 classical
- Accuracy: 5 % UM (3 % for DC)
Power quality assessment and troubleshooting in low voltage electrical systems. Measuring range: UM < 3 %UN and continuous non supervised operation. instruments (voltmeters, ampermeters, cos j meters, etc.).
Balancing phase currents in 3-phase systems. - Resolution: 0.1 %
- Accuracy: 0.15 % UN
Checking power correction equipment performance. UN: nominal voltage (TRMS)
x A/5 A
L1
Harmonics spectrum analysis for selection of harmonic filters. UM: measured harmonic voltage hM = 1st 50th x A/5 A
L3
Capturing inrush currents e.g. motor's start up currents. x A/5 A
L3
Current harmonics
Voltage deviations recording. Measuring range: IM > 3 %IN
Consumption recording. - Resolution: 0.1 % N
- Accuracy: 5 % IM (3 % for DC)
Main features Measuring range: IM < 3 %IN
- Resolution: 0.1 % 1............................30
Simultaneous analysis of basic power quality - Accuracy: 0.15 % IN
parameters (U,I,P,Q,S, PF). Power Q IN: nominal range (TRMS)
25 V/0,5 A

Harmonics analysis up to 50th component. Simplified version of Power QPlus IM: measured harmonic current hM = 1st 50th

Phase diagram. with all basic measurement Loggers


Voltage unbalance calculation for 3-phase systems. functions. Voltage and current logger
On-line scope function. Compatible user interface, Signals: selectable U1, U2, U3, I1, I2, I3 COM
INPUT 1
Interval: selectable (1, 2, 5, 10,15, 30) seconds RS 485 INPUT 2

Lightweight design. manipulation and software with or (1, 2, 5, 10, 15, 30) minutes
INPUT 3
INPUT 4

Downloading software package PowerQ Link. Power QPlus. Displayed data: min., average and max. value of RS 232/USB/RS 485 OUTPUT 1

the interval OUTPUT 2

Power logger
Signals: selectable L1, L2, L3, TOT
Interval: selectable (1, 2, 5, 10, 15, 30) seconds
or (1, 2, 5, 10, 15, 30) minutes
Displayed data: min., average and max. value of
Technical specification - Power QPlus the interval (for all four quadrants) Technical specifications Ordering information
Voltage Power Harmonics logger Configuration: 3 voltage inputs, 3 current inputs General specification Standard Set: Part No. MI 4100
Three-phase AC voltage input Measured parameters: Signals: selectable THDI1, THDI2, System: single phase, 3-phase Power supply voltage: 180 V a.c. 260 V a.c.), - Instrument Power Monitor
(3 differential inputs, L1-N, L2-N, L3-N) - Active power (P) THDI3, THDU1, THDU2, THDU3, (3 or 4 wire unbalanced load) 50 Hz/60 Hz - Instruction manual
Input voltage range: 3 - 550 VRMS L-N - Reactive power (Q) Interval: selectable (1, 2, 5, 10, 15, 30) Measuring principle: 4 quadrants, 10 periods, 128 scans/period Protection classification: double insulation - Product verification data
3 - 550 VRMS L-L - Apparent power (S) seconds or (1, 2, 5, 10, 15, 30) Display update: 1 update/s, harmonics 1 update/5 s Pollution degree: 3 - Declaration of conformity
Resolution: 0.1 V - Power factor minutes Direct connection of current inputs to standard CTs with 5 A output Protection degree: IP 40
Crest factor: 1...1.4 (1.4 @ 550 VRMS L-N) - Cos j Displayed data: min., average and max. value of Wide voltage range from 0 V to 500 V Overvoltage category: CAT II 600 V/CAT III 300 V
Frequency range: 45 66 Hz - Energy (kWh, vah, varh) the interval Backlit LCD with 4 x 20 characters Load: 5 VA max.
Current Accuracy: Inrushes 42 days of active and reactive energy logging Dimensions (w h d): 96 mm 96 mm 100 mm
Three-phase AC input for connection to current - Power: (3 % + 3 dig) Signals: selectable U1, U2, U3, I1, I2, I3 RS 485 communication port Standards applied: EN61010-1, EN 61326
transducers with voltage output. - Power factor: Interval: selectable, (10, 20, 100, 200) ms
Range 1: 0.004 VRMS 0.1 VRMS (4 A 100 A) Range 1: 0.00 0.39; Accuracy 0.06 Trigger channels: I1, I2, I3
Resolution: 0.1 A Range 2: 0.40 1.00; Accuracy 0.03 Trigger level: electable, 2 % 100 % of current
Crest factor: 1... 2.3 @ 0.1 VRMS All measurements are performed in four quadrants: load range (in steps of 0.1 % of
Range 2: 0.04 VRMS 1 VRMS (40 A 1000 A) or generator with capacitive or inductive character. current range)
Resolution: 0.1 A Displayed data: min., average and max. value of
4 Crest factor: 1... 2.3 @ 0.1 VRMS the interval 9
Power Quality Analysis
Power Quality Analyser-Plus Power Quality Analyser Power Harmonics Analyser Power QPlus Power Q VoltScanner
Main features

Ordering No.: MI 2292 MI 2192 MI 2092 MI 2392 MI 2492 MI 2130


Power Quality Testing
RMS Voltages, Currents (average, min., max.) ( voltage only)
Harmonics Analysis Optional
THD
Power
Active, Reactive, Apparent
Cos j
Character, sign
Voltage Events (dips, sags, interruptions)
Logger (U, I, P, Q, S) Optional
Periodic Analysis
Statistical Analysis
Anomalies (Events) Analysis
VoltScanner Neutral current (calculated)
On line monitoring
Meter mode - tabelaric results
Scope mode - osciloscope
Spectrum Analysis mode Optional
EN 50160 compliant testing
Plug and measure solution to analyse the quality of the line voltage in Fast Set Up - Auto mode
accordance with EN 50160 Technical specification Voltage
Measurement THD & Harmonics
The VoltScanner is a simple instrument designed to record voltage characteristics at the Phase to Neutral Dips, Sags, Interruptions
customers supply terminals in public electricity distribution systems, according to the Range Accuracy Resolution
Flicker
90 to 265 V 2 V of reading + 2 % 1V
EN 50160 standard. Neutral to Ground
Frequency
Range Accuracy Resolution Interharmonics / Signalling
It records voltage dips, swells, transient overvoltages, frequency variations and supply
0 to 155 V 2 V of reading + 2 % 1V Unbalance
interruptions. Frequency EN 50160 Test Report
A flashing LED indicates that events have been captured Range Accuracy Resolution
4752 Hz, 0.1 Hz 0.1 Hz
Special tools
Memory capacity of up to 3500 events 5762 Hz 0.1 Hz 0.1 Hz Fast logging mode (166 minutes) (8,4 minutes)
Transients Waveform mode (7812 periods) (390 periods)
Operating procedure Range Accuracy Resolution Transient mode (1000 periods) (50 periods)
50 to 2600 V 10 % 5V
Set-up limit values Downloading Energy
Minimum width: 1 s
Custom or EN 50160 auto-mode Analysis Total & Subtotal counters
Plug-in - Periodics (max., min., General Other
Nominal Supply Voltage: 230 V or 120 V Optional
Measuring & Recording or average values) - table or graph. PC SW
Nominal Frequency: 50/60 Hz
Events mode Modem entrance key Optional Optional
- Statistics of all the events by character, Communication: RS 232 serial interface,
Dips/Sags, Swells magnitude, time stamp. fully opto isolated, 9 pin D-type connector
Voltage interruptions Memory: 32 kB, 3500 events
Detailed reports and graphs Battery: 6 V DC (4 x 1.5 V AA) Rechargeable Typical application areas Possible corrective solutions Suitable Metrel Power Quality Analyser
Frequency fluctuations Overvoltage category: CAT III 300 V
Transients overvoltage General - General power quality assessment - PF correction equipment - PowerQ Plus MI 2392
Power - Power factor correction - Filters - Power Harmonics Analyser MI 2092
Periodics mode
Ordering information Quality - Harmonics filtering - UPS - Power Quality Analyser MI 2192
Power frequency
Standard Set: Part No. MI 2130 Testing - Power peak reduction - Power conditioners - Power Quality Analyser Plus MI 2292
Supply voltage
- Power breaks capturing
EN 50160 auto-mode

ScanLink EN 50160 - Assessment of supply voltage quality - Dealing with customers complaints - PowerQ Plus MI 2392
ScanLink Windows 95/98/2000/NT Voltage at end users - UPS - Power Quality Analyser MI 2192
software for analysing and print-outs Quality - Assessment of voltage quality at end - Ferro-resonants transformers - Power Quality Analyser Plus MI 2292
with a complete history of captured users - Backup generators - Voltscanner MI 2130 (1-phase only)
Evaluation
events in a tabelaric or graphic form - Assessment of voltage quality in - Power conditioners
(statistics). electrical generation systems
By analysing periodics it enables review - Instrument VoltScanner
- Mains measuring cable, 1.5 m
of voltage quality against the set limits - Battery-rechargeable NiMH 1.2 V, 4 pcs Waveforms - Analysing of influences of motor start-ups - Power Quality Analyser MI 2192
- Voltage regulators
(Custom or EN 50160 auto-mode). - Windows Software "ScanLink - Analysing of load variations
Recording - Power conditioners - Power Quality Analyser Plus MI 2292
Periodics analysis of voltage variation for the past - RS 232 cable - Analysing of non-linear loads - UPS
3 weeks - Instruction Manual
- Declaration of conformity - Ferro-resonant transformers
- Product verification data - Filters

Optional accessories Transients - Analysis of oscillatory transients caused - UPS - Power Quality Analyser MI 2192
S 2010 Capturing by lightning - Overvoltage protection devices - Power Quality Analyser Plus MI 2292
- Analysis of electrostatic discharges - Analysis of switching
- Analysis of switching manouvres manouvres

A 1020 S 1112 A 1171


Fast Logging - Analysing of influences of motor start-ups - Voltage regulators - Power Quality Analyser MI 2192
A 1020 - Small soft carrying bag
Recording - Analysing of load variations - Power conditioners - Power Quality Analyser Plus MI 2292
A 1171 - Adapter USB / RS232
S 1112 - Universal test cable 3 x1.5 m with 3 safety - UPS - PowerQ Plus MI 2392
test tips
10 Set-up of event recording or periodics recording mode Statistics of the captured events S 2010 - Set of Alligator clips(black), 3 pcs 3
Multifunctional Power Quality Analysers Power Quality Accessories Application Guide
Power Quality Analysis

There are quite a few reasons for measuring and analysing power quality nowadays. Seamless integration of measurement equipment with the analysed object becomes of paramount importance and serves as a great help for
Our work mostly depends on computers and machines supplied by electrical power. technicians on site. Therefore a wide selection of accessories for the entire range of Metrel's digital Power Quality Analysers is available.
Therefore, problems with electrical power - directly impact our work. Recommended use for every product is described in the following guidelines.
What is a power quality problem? This is every deviation of the electricity applied to the More detailed specifications of the products offered can be supplied on request.
equipment which results in damage or misoperation of electronic equipment or other
electrical devices. Current clamps, transformers and Typical applications A 1037 - Three-phase current transformer 5 A/1V
Large capacity measuring head will accommodate
Some common symptoms of power quality problems in facilities are: adapters conductors of various shapes and dimensions.
- Unexplained equipment trips or shutdowns. This range of products extends the versatility of the This set is suitable for 1 or 3-phase current
Power Quality Analyser family and provides safe,
- Occasional equipment damage or component failure. accurate and non-intrusive measurements in
measurements up to 3000 A.
For 3-phase measurements at least 3 pieces of A 1099
- Erratic control of process performance. applications which cannot be accessed with are required.
- Random lockups and data errors. conventional cable connections. With proper connection we can choose between 3-wire
- Power system component overheating. A 1033 - Current Clamps 1000 A / 1 V (3 x A 1099), 4-wire (3 x A 1099) or Aaron (2 x A 1099)
power measurement.
If we look at those technical problems from the economic point of view, this means that Hint Maximum measuring current: 5 A AC
Frequency range: 40 Hz to 5 kHz
we have to deal with: decreased production, time delays, additional expenses and With proper selection of the measuring current range
Voltage output: 200 mV/A
the accuracy can be considerably improved.
company reputation. Therefore good power quality is a must for a normal business flow. Availability Accuracy in %: 0,3 %
Metrel Power Quality Analyser product line will help you find many problems on your Optional. Overvoltage category: 600 V, CAT III
Typical applications
site such as: Measuring range: 0,2 A to 1200 A AC Normally used in power sub-stations with standard
- Identifying sensitive electrical devices. Frequency range: 40 Hz to 5 kHz A 1069 - Mini Clamp 100 A / 1 V with 5 A AC current output.
Typical applications include 3 phase power quality
- Early detection of potential errors. Voltage output: 1 mV/A A 1039 - Clamp Adapter for connection
measurements.
Accuracy in %: 3 at 0.110 A; 3 at 10 A; 2 at 20 A;
- Electrical network optimization or expansion on power quality measurements basis. 1,1 at 200 A; 1 at 1000 A; 1 at 1200 A In case standard current output is present no
Overvoltage category: 600 V, CAT III additional current clamps are needed.
Metrel instruments are easy to use and housed in durable cases, designed for rough Maximum conductor diameter: 51 mm
This set is especially helpful when performing long-
term measurements because there is no need to
environment. They have outstanding price/performance ratio. Maximum aperture: 55 mm
break the electrical circuits.
Typical applications Availability
Designed for use in applications requiring measurement Optional.
Maximum measuring current: 100 A AC
of current without interrupting the electric circuit.
Jaws can be snapped open, placed around the
Frequency range: 40 Hz to 5 kHz Connection cables and adapters
Voltage output: 10 mV/A Introduced range of accessories will safely connect
Typical applications of individual instruments conductor and snapped closed to form a magnetic loop Accuracy in %: 2% at 5 10 A; 1% at 10 100 A the Power Quality Analysers to the measured circuit.
around the conductor. Overvoltage category: 600 V, CAT III Although some of the presented items are not
FLICKER DIAGRAMS STATISTICS REPORTS Hint Maximum conductor diameter: 15 mm included in a standard set they can be ordered
If a clamp is snapped around both wires of a single- Maximum aperture: 15 mm separately when the need occurs.
phase electric network, a leakage current to ground will Typical applications S 2014 Safety Fuse Adapters
be measured. Designed for use in applications requiring measurement
Availability of current without interrupting the electric circuit.
3 pieces are supplied in a standard set. Most frequently used in current and power
A 1120 - Three-phase flex kit 3000 A / 1 V measurements.
Jaw dimensions make them suitable for measurements
on round conductors with a diameter up to 15 mm on
larger single phase systems, telecommunication
applications, switch boxes.
For 3-phase measurements at least two clamps (Aaron Overvoltage category: 600 V, CAT III
Transients capturing with MI 2192 Power Quality Analyzer. Nominal current: 20 A
connection) are required.
Transients can appear due to atmosphere discharges, switching Breaking capacity: 100 kA
Standardized voltage output allows the transformer to
maneuvers or capacitor banks switching. Records can be effectively 4 mm safety connection
be connected to other instruments with 1 V AC input.
used for over voltage protection selection. Note Typical applications
Maximum measuring current: 30 A / 300 A / 3000 A AC Designed for voltage measurements and for
For connecting the current transformer to an instrument
Frequency range: 2 Hz to 5 kHz protection of electrical equipment as well as
Power quality assessment A 1039 Clamp Adapter has to be purchased.
Voltage output: 33,3 mV/A; 3,33 mV/A; 0,33 mV/A electricians in high energy LV systems.
according to EN 50160 and Accuracy: +/- 1% of reading in reference conditions Availability The adapter can be equipped with an efficient low
flicker measurement Overvoltage category: 600 V, CAT III Optional. voltage fuse which reliably isolates the measuring
performed with MI 2292 Length of the measuring head: 450 mm circuit from the mains supply in the event of
Power Quality Analyser Maximum head capacity: 130 mm A 1122 - Mini Clamp 5 A / 1 V with excessively high current load.
Plus. Fuses are not supplied!
A 1039 - Clamp Adapter for connection
Typical applications Availability
Because of their flexibility these current transducers Optional.
will accommodate conductors of various shapes and S 2015 Flat contact Clamps
dimensions. This set is suitable for 3-phase current
Waveform analysis performed either with MI 2192 Power Quality measurements up to 3000 A.
Analyser or MI 2292 Power Quality Analyser Plus. Useful feature Typically used in power quality measurements on
for determining harmonics direction, UPS performance evaluation or larger objects (transformers, sub-stations).
motor's start-up analysis. Hint Maximum measuring current: 5 A AC
With proper selection of the measuring current range Frequency range: 40 Hz to 5 kHz
the accuracy can be considerably improved. Voltage output: 200 mV/A
Availability Accuracy in %: 3% at 0 5 A
Available on request. Overvoltage category: 600 V, CAT III
Maximum conductor diameter: 15 mm Overvoltage category: 600 V, CAT III
Maximum aperture: 15 mm Nominal current: 5 A
A 1099 - Single-phase flex kit 3000 A / 1 V Typical applications Maximum thickness of flat conductor bar: 30 mm
These clamps feature similar properties as the A 1069. 4 mm safety connection
Jaw dimensions make them suitable for measurements Typical applications
on round conductors with a diameter up to 15 mm. Foreseen for voltage measurements. Clamps provide
Nominal current range up to 5 A AC is ideal for reliable grip for safe measurements.
measurements in IT environments, on smaller With adjustable stop they are particularly useful for
electronically regulated loads with high content of making connections on bus bars and other large
Different pre-set loggers within MI 2392 PowerQ Plus allow quick harmonics. sized conductors which cannot be embraced with
Maximum measuring current: 30 A / 300 A / 3000 A AC crocodile clips.
on-site power quality assessment without a need to download Note
Frequency range: 10 Hz to 20 kHz Standardized 4mm safety connection makes them
recorded data on a PC. Examples show phase diagram which helps Periodic measurement of basic power quality parameters (U,I, P, Q, S, For connecting the current transformer to an instrument,
Voltage output: 33.3 mV/A; 3.3 mV/A; 0.33 mV/A suitable for use with other instruments.
when connecting the instrument on power supply network U, I, f PF, etc.) with harmonics analysis performed with MI 2092 Power Accuracy: 1% of range
A 1039 Clamp Adapter has to be purchased.
Availability
logger is a useful feature for measurement conditions evaluation. Harmonics Analyser. Availability
Overvoltage category: 600 V, CAT III Optional.
Optional.
Length of the measuring head: 600 mm - 4 pcs included in a Standard set for MI 2292.
2 Maximum head capacity: 178 mm 11
2006
www.metrel.si 2007
Test Tips Communication accessories Power Simulator set
- Overvoltage Measurements on several remote locations One phase, multi-purpose power simulator for
category: 1000 V, simultaneously - with a possibility to control Power Quality simulating typical situations in low voltage power
CAT III measuring equipment from a single location - become true
supply systems.
- 4 mm with the following communication equipment.
Excellent tool for training and demonstration
connection. A 1100 - Modem ST purposes.
Typical applications
Simulation of transients, inrush currents, flickers,
4 mm safety connection of the tips makes them
harmonics, power supply outages, etc.
suitable for performing measurements in mains
Load character adjustment, adjustable current and
outlets or quick, indicative voltage measurements.
voltage level with a simulation of 22 different faulty
Availability
conditions.
3 pieces included in a standard set.
Optional: 110 V version.
Dimensions (w x h x l): 265 x 110 x 185 mm.
Voltage measurements cables Mass (without accessories): 2,4 kg.
- Overvoltage category:
1000 V, CAT III
- 4 mm connection. A 1101 - Modem GSM

Typical applications
POWER QUALITY ANALYSIS
Thanks to 4 mm safety connection which fits the
entire range of accessories supplied in the Power
Quality set, the cables can be used in a vast number of
different applications.
Availability
3 pieces included in a Standard set. A 1124 - Modem Entrance Key
Ordering Information
Alligator Clips Typical applications
Standard Set Part No. MI 2191
- Overvoltage Using modem connection between the instrument and
category: 1000 V,
the PC enables the following tasks to be completed:
CAT III - Remote programming of the instrument via PC.
- 4 mm - Downloading recorded data via PC from a remote
location.
connection.
- Receiving SMS alarms (task completed, full memory,
Overvoltage category: 1000 V, CAT III 20 % of memory is free, 50 % of memory is free,
recording is finished).
4 mm connection.
- Clear memory.
Typical applications
Connectivity
Usually used in voltage measurements. They feature
Communication modems come installed on the
firm, reliable grip for safe measurements. instruments and the PC side.
Standardized 4mm safety connection makes them The following combinations are possible:
suitable for use with other instruments. PC side can be equipped either with standard analog
Availability A 1100 Modem ST or with A 1101 Modem GSM.
3 pieces included in a Standard set. The instrument can either have standard analog external
modem A 1100 Modem ST or A 1101 Modem GSM.
- Instrument Power Simulator
A 1171 - Adapter USB / RS232 In case analog phone line is available, A 1100 Modem ST
is used. If not, A 1101 Modem GSM has to be used. - Short form quick guide plastic cards
- RS232 USB Cable Style
A 1124 Modem Entrace Key activates access to the - Power cord
Converter with 1m fixed cable
modem support. - Current measuring cable
- Users manual and Installation
Availability - Instruction manual
guide
- CD Modern Power Quality measurement techniques
- Driver and utility CD - Modems are supplied optionally.
- Declaration of conformity
- A 1124 Modem entrance Key is included in a Standard
Cable can be used to connect instruments with RS232 port - Product verification data
set of MI 2292 Power quality Analyser Plus.
on USB port on PC. Enhanced converter is able to support - A 1124 Modem Entrance Key for MI 2192 and MI 2092
RS232 Baud rates of up to 460k Baud. is available optionally.

Note! Photographs in this catalogue may slightly differ from the instruments at time of delivery.
Subject to technical change without notice.

PowerQ Plus
PowerQ
Power Quality Analyser Plus
Measuring and Regulation
Power Quality Analyser
Equipment Manufacturer d.d.
Ljubljanska 77 Power Harmonics Analyser
SI-1354 Horjul Power Monitor
Tel: + 386 (0)1 75 58 200 VoltScanner
Fax: + 386 (0)1 75 49 226 Power Simulator
E-mail: metrel@metrel.si
http://www.metrel.si

You might also like