10 343

You might also like

Download as pdf
Download as pdf
You are on page 1of 2
For telecommunications applications 48 Vdc, 50 Adc per Rectifier or 200 Adc per shelf * Switched-mode * Active power factor correction, 0.99 PF Shelf-mounted Automatic load sharing Nominal output voltage 48 Vdc High efficiency (90 percent) Two types of operation The modular rectifiers can be used in redundant or non-redundant modes. The modules are shelf-mounted and can be installed or removed while the system is operational. Modules include front panel indicator LEDs, input and output circuit breakers and a 3.5-digit ammeter. The unit incorporates an inservextract handle which makes connections/disconnects trouble-free, and a field-replaceable cool- ing fan. Shelf mounting The modules are housed in a shelf, which is designed to mount in a 23-inch rolay rack. Each eholf houses up to four modules. ‘Dc output connections are made on tne side of the shelf; ac input connections are made inside the shelf. Load sharing Forced or passive load sharing between modules of the same operating voltage is provided in order to offer equal power dis- tribution from no load to full load between modules in parallel applications. Designed for all applicable international safety requirements, including EMI filter- ing to FCC and VDE-0875, Class N limits. High-voltage shutdown (HVSD) The rectifier has a built-in, HVSD funo- tion. No single component failure (short or open) will rooult in an output voltage greater than 60 volts. After a remote HVSD signal is received or an internal ohutdown ocouro, the reetifior may be reset locally or remotely. SPECIFICATIONS INPUT Voltage 208/220/240 Vac, single-phase; Operaiing range 176 to 264 Vas, no tape required Frequency 45 to 65 He Protection 2:pole circull breaker OUTPUT Voltage Floal voltage i aijustabie iron 38 to 00 valls Us Equalize voltage is adjustable from 48 to 60 volts de ‘Current ‘Current limit: adjustable from 0 to 50 amps Regulation 055 percent for 0 fo 100 percent load, within the specified input voltage and frequency range Filtering Voice band — less than 32 dBm0 ‘Wide band noise — less than 350mV, peak-to-peak, over a 410 Hz to 14mHz range Protection Circuit breaker ‘Overvoltage — ‘shutdown ‘Adjustable up to 60 Valo Turn-on Soft start a Load current ‘Modules share within +10 percent from 1016 100 percent rating ENVIRONMENT (Operating temperature 40 F (-406) o 149 F (656) ‘Storage ‘temperature 58 F (500) 10 +185 F (850) Humidity (0-95 percent relative humidity, non condensing Anitude (Oto 7,000 feet (010 2,139 meters) Em (FUG Part 15, Subpart J 10r Class A equipment, VUEGN7S, Class N ‘Audible noise | Loss than 55 dBA, five foot from any vertical surface Module weight | 25 bs (11.4 Kgs) Module height | 12.25" (31.750m) when mounted in shell ‘Shelf depth 145% (@7em) maximum POWERCOM DIVISION 1400 Union Mooting Road Biue Bell, PA 19422-0858 Phone (215) 619-2700 Fax (215) 619-7899, ‘www.cdpowercom.com 3400 East Britannia Drive ‘Spucteato et car teas en Conte urn CAD sna fen el pais teers, eatin {dus guon eon an tlavedts be costa aa mle te receiv ua, nara openly ry in ns ed ‘Sunort or uggsera covering pow ot pec nade arent ener © are ft hy esc usesPec pte Suite 122, Tucson, AZ 85706 remuwran. one ae retrecornercaone wren Eomn. ie ws’ cue et se Wa a aoy Mensou tates oat Set Phone (520) 295-4300 Fax (520) 295-4091 ‘meaies nay note eae Uses mu rly rang 1 fe car CAD rae to renner arr owas ‘Beuchncheegy puso ae nce an stan mri se nt Sao shea ean Pa C8 ‘Seotocre oignon'o nom te tres any odors an psn ch dehy sors ane ass

You might also like