1.1 STRUCTURAL DESIGN OF MAT FOUNDATIONS
Conventional Rigid Method
1.2 Approximate Flexible Method
Foundations on Sandy Soils
Foundations on Clays
1.3 Example
1.4 PROBLEMS
The structural design of mat foundations can be carried out by two conventional methods:
the conventional rigid method and the approximate flexible method. Finite difference and
finite element methods can also be used, but this section covers only the basic concepts of
the first two design methods.
The conventional rigid method of mat foundation design can be explained step by step
with reference to figure 5.8.
= 1 + 2 + 3 [5.24]
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
= [5.25]
Where
The load eccentricities, and , in the and directions can be determined by using
( , ) coordinates:
1 1 +2 2 +3 3 +
= [5.26]
And
= 2 [5.27]
Similarly
1 1 +2 2 +3 3 +
= [5.28]
And
= 2 [5.29]
3. Compare the values of the soil pressures determined in step 2 with the net
allowable soil pressure to determine whether all (net ) .
4. Divide the mat into several strips in x and y directions (see figure 5.8a). Let the
width of any strip be 1 .
5. Draw the shear, V, and the moment, M, diagrams for each individual strip (in the x
and y directions). For example, the average soil pressure of the bottom strip in the
x direction of figure 5.8a is
+
[5.30]
2
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Where
The total soil reaction is equal to 1 . Now obtain the total column load on the strip
as 1 + 2 + 3 + 4 . The sum of the column loads on the strip will not equal 1
because the shear between the adjacent strips has not been taken into account. For this
reason, the soil reaction and the column loads need to be adjusted, or
1 +(1 +2 +3 +4 )
Average load = [5.31]
2
So, the modified column loads are 1 , 2 , 3 , and 4 . This modified loading on the
strip under consideration is shown in figure 5.8b. The shear and the moment diagram for
this strip can now be drawn. This procedure is repeated for all strips in the x and y
directions.
6. Determine the effective depth of the mat d by checking for diagonal tension shear
near various columns. According to ACI Code 318-95. American Concrete
Institute, 1995), for the critical section,
= [(0.34) ] [5.34]
Where
The units of and in equation (34) are in meters. In English units, equation (34) may
be expressed as
= (4 ) [5.35]
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Where
The expression for in terms of , which depends on the location of the column with
respect to the plan of the mat, can be obtained from figure 5.8c.
7. From the moment diagrams of all strips in one direction (x or y), obtain the
maximum positive and negative moments per unit width (that is, = /1 ).
8. Determine the areas of steep per unit width for positive and negative
reinforcement in the x and y directions.
= ( )(load factor) = 2 [5.36]
And
= 0.85 [5.37]
Where
Examples 5 and 6 illustrate the use of the conventional rigid method of mat foundation
design.
In the conventional rigid method of design, the mat is assumed to be infinitely rigid.
Also, the soil pressure is distributed in a straight line, and the centroid of the soil pressure
is coincidental with the line of action of the resultant column loads (see figure 5.9). In the
approximate flexible method of design, the soil is assumed to be equivalent to infinite
number of elastic springs, as shown in figure 5.9b. It is sometimes referred to as the
Winkler foundation. The elastic constant of these assumed springs is referred to as the
coefficient of subgrade reaction k.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Figure 5.9 (a) Principles of design conventional rigid method; (b) principles of
approximate flexible method; (c) derivation of equation (42) for beams on elastic
foundation
2
= 2 [5.38]
Where
= moment of inertia of the cross section of the beam = 121 1 3 (see figure 5.9c)
However
= shear force =
And
= = soil reaction
Hence
2
= [5.39]
2
Where
= deflection
= 1
So
4
4 = 1 [5.41]
4
= 41 [5.43]
The unit of the term as defined by the preceding equation is (length)1 . This
parameter is very important in determining whether a mat foundation should be designed
by conventional rigid method or approximate flexible method. According to the
American Concrete Institute Committee 336 (1988), mats should be designed by the
conventional rigid method if the spacing of columns in a strip is less than 1.75/. If the
spacing of columns is larger than 1.75/, the approximate flexible method may be used.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
To perform the analysis for the structural design of a flexible mat, you must know the
principles of evaluating the coefficient of subgrade reaction, k. before proceeding with
the discussion of the approximate flexible design method, let as discuss this coefficient in
more detail.
If a foundation of width B (figure 5.10) is subjected to a load per unit area of q, it will
undergo a settlement, . The coefficient of subgrade modulus, k, can be defined as
= [5.44]
The unit of is kN/m3 (or lb/in3 ). The value of the coefficient of subgrade reaction is
not a constant for a given soil. T depends on several factors, such as the length, , and
width, , of the foundation and also the depth of embedment of the foundation. Terzaghi
(1955) made a comprehensive study of the parameters affecting the coefficient of
subgrade reaction. It indicated that the value of the coefficient of subgrade reaction
decreases with the width of the foundation. In the field, load tests can be carried out by
means of square plate measuring 1 ft 1 ft (0.3 m 0.3 m) and values of k can be
calculated. The value of k can be related to large foundations measuring in the
following ways.
+0.3 2
= 0.3 [5.45]
2
Where
+1 2
= 1 2 [5.46]
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Where
Foundations on Clays
0.3 (m)
(kN/m3 ) = 0.3 (kN/m3 ) (m) [5.47]
In English units,
1 (ft)
(lb/in3 ) = 1 (lb/in3 ) (ft) [5.48]
For rectangular foundations having dimensions of (for similar soil and q),
( ) 1+0.5
= [5.49]
1.5
Where
() =
coefficient of subgrade modulus of a square foundation having dimension of
Equation (49) indicates that the value of k of a very long foundation with a width B is
approximately 0.67() .
The modulus of elasticity of granular soils increases with depth. Because the settlement
of a foundation depends on the modulus of elasticity, the value of k increases as the depth
of the foundation increases.
Following are some typical ranges of value for the coefficient of subgrade reaction 1 for
sandy and clayey soils.
Sand (saturated)
Clay
Scott (1981) proposed that for sandy soils the value of 0.3 can be obtained from standard
penetration resistance at any given depth, or
Where
In English units,
For long beams, Vesic (1961) proposed an equation for estimating subgrade reaction:
12 4
= 0.65 [5.52]
1 2
Where
= foundation width
= (1 2) [5.53]
The coefficient of subgrade reaction is also very useful parameter in the design of rigid
highway and airfield pavements. The pavements with a concrete wearing surface are
generally referred to as a rigid pavement, and the pavement with an asphaltic wearing
surface is called a flexible pavement. For surface load acting on a rigid pavement, the
maximum tensile stress occurs at the base of the slab. For estimating the magnitude of the
maximum horizontal tensile stress developed at the base of the rigid pavement, elastic
solutions involving slabs on Winkler foundations are extremely useful. Some of the early
work in this area was done by Westergaard (1926, 1939, and 1947).
Now that we have discussed the coefficient of subgrade reaction, we will proceed with
the discussion of the approximate flexible method of designing mat foundations. This
method, as proposed by the American Concrete Institute Committee 336 (1988), is
described step by step. The design procedure is based primarily on the theory of plates.
Its use allows the effects (that is, moment, shear, and deflection) of a concentrated
column load in the area surrounding it to be evaluated. If the zones of influence of two or
more columns overlap, superposition can be used to obtain the net moment, shear, and
deflection at any point.
1. Assume a thickness, h, for the mat, according to step 6 as outlined for the
conventional rigid method. (Note: h is the total thickness of the mat).
3
= 12(1 2) [5.54]
Where
Where
= coefficient of subgrade reaction
4. Determine the moment (in polar coordinates at a point) caused by a column load
(figure 5.11a):
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
(1 )2
= radial moment = 4 1 [5.56]
(1 )2
= tangential moment = 4 1 + [5.57]
Where
The variations of 1 and 2 with / are shown in figure 5.11b (for details, see
Hetenyi, 1946).
5. For the unit width of the mat, determine the shear force, V, caused by a column
load:
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
= 4 3 [5.60]
6. If the edge of the mat is located in the zone of influence of a column, determine
the moment and shear along the wedge (assume that the mat is continuous).
Moment and shear opposite in sign to those determined are applied at the edges to
satisfy the known conditions.
7. Deflection () at any point is given by
2
= 4 [5.61]
4
Example 5
The plan of a mat foundation with column loads is shown in figure 5.12. Use equation
(25) to calculate the soil pressures at points , , , , , , , , , , , , , and . The
size of the mat is 76 ft 96 ft, all columns are 24 in. 24 in. in section, and all (net ) =
1.5 kip/ft 2 . Verify that the soil pressures are less than the net allowable bearing capacity.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Solution
Column dead load () = 100 + 180 + 190 + 110 + 180 + 360 + 400 + 200 +
190 + 400 + 440 + 200 + 120 + 180 + 180 + 120 = 3550 kip
Column live load () = 60 + 120 + 120 + 70 + 120 + 200 + 250 + 120 + 130 +
240 + 300 + 120 + 70 + 120 + 120 + 70 + 2230 kip
So
And
= 0
So
= 36.664 ft
And
Similarly,
= 0
So
= 44.273 ft
And
Or
The soil pressures at all points are less than the given value of all (net ) = 1.5 kip/ft 2 .
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Example 6
Solution
For the critical perimeter column as shown in figure 5.13 *(ACI 318-95),
Where
= (4) = (0.85)(4)(3000)(96 + 2)
So
(0.85)(4)(3000 )(96+2)
487
1000
(96 + 2) 2615.1
19.4 in.
= 4(24 + ) = 96 + 4(in. )
And
(0.85)(4)(3000 )(96+4)
1126
1000
(96 + 4) 6046.4
28.7 in.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Use = 29 in.
With a minimum cover of 3 in. over the steel reinforcement and 1-in. diameter steel bars,
the total slab thickness is
= 29 + 3 + 1 = 33 in.
1.253+1.233+1.212
2 = = 1.233 kip/ft 2
3
1.294+1.273+1.253
2 = = 1.273 kip/ft 2
3
1.318+1.294
2 = = 1.306 kip/ft 2
2
Check for = 0:
Refer to figure 5.15 for the design of strip BCDKLM. Figure 5.15 shows the load
diagram, in which
The shear and moment diagrams are shown in figure 5.15b and c, respectively. From
figure 5.15c, the maximum positive moment at the bottom of the foundation =
2281.1/24 = 95.05 kip ft/ft.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Figure 5.15
Figure 5.16 Rectangular section in bending; (a) section, (b) assumed stress distribution
across the section
For the design concepts of a rectangular section in bending refer to figure 5.16.
Tensile force, =
(0.85)(3)(12) = (60)
= 0.51
(95.05)(12) = (0.9)(0.51)(60) 29
2
= 1.47 in.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Thus
From figure 5.15c, the maximum negative moment = 2447.8 kip ft/24 = 102 kip
ft/ft. by observation, (min ) .
Example 7
From the plate load test (plate dimension1 ft 1 ft) in the field, the coefficient of
subgrade reaction of a sandy soil was determined to be 80 lb/in3 . (a) What will be the
value of the coefficient of subgrade reaction on the same soil for a foundation with
dimensions of 30 ft 30 ft? (b) if the full-sized foundation has dimension of 45 ft
30 ft, what will be the value of the coefficient of subgrade reaction?
Solution
Part a
+1 2
= 1 2
Where
1 = 80 lb/in2
= 30 ft
So
30+1 2
= 80 (2)(30) = 21.36 in3
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Part b
So
(21.36)(1+0.530
= 45
= 19 lb/in3
1.5
PROBLEMS
1. Determine the net ultimate bearing capacity of mat foundation with the following
characteristics:
a. = 120 kN/m2 , = 0, = 8 m, = 18 m, = 3 m
b. = 2500 lb/ft 2 , = 0, = 20 ft, = 30 ft, = 6.2 ft
2. Following are the results of a standard penetration test in the field (sandy soil):
Figure P-1
6. Refer to figure P-2. For the mat,
1 , 3 = 40 tons, 4 , 5 , 6 = 60 tons, 2 , 9 = 45 tons, and 7 , 8 = 50 tons.
all columns are 20 in. 20 in. in cross section. Use the procedure outlined in
section 7 to determine the pressure on the soil at A, B, C, D, E, F, G, and H.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Figure P-2
7. The plan of a mat foundation with column loads is shown in figure P-3. Calculate
the soil pressure at points A, B, C, D, E, and F. note: all columns are 0.5 m
0.5 m in plan.
NPTEL - ADVANCED FOUNDATION ENGINEERING-1
Figure P-3