CAM
When storing an uncrated tower panel, always store it in a
vertical upright position to prevent moisture accumulation
inside the panel. Never store the panel upside down or on
its side.
Turn the cam so it is in proper relation to the switches as
shown below.
During installation, take care not to damage the micro-
switches. Make sure the switches are riding on the edge
of the cam and not underneath.
Span cables to and from the tower panel must not limit
the tower panel movement. A free loop of span cable and
motor drop cable is necessary at each tower panel except
for the last tower. ALIGNMENT
SWITCH
SAFETY SWITCH
The Safety switch should click when the roller pin crosses
the dotted line (See following diagram). After the correct
actuating (click) position is found, there should also be a
slight movement of the switch arm before reaching the outer edge of the cam.
Note: All switches must be checked for proper operation after installation.
4. When securing, make certain the cam retainer arm points to the center of the cam as shown.