Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

DESIGN OF LIGHT GAUGE STEEL PURLIN SECTION

Data:
V= 200 KPH LL = 1000 N/m2 Wt Rf & Ceiling = 310.16
Kzt = 1 L= 3.5 m Fy = 248
Iw = 1 S max = 0.6 m Fb = 148.8
G= 0.85 sin = 0.248937 Kd = 0.85
Kz = 1.024 cos = 0.96852 (ww)Cp = 0.723416
= 14.41461 Degrees Wt. Pur = 49.7367 N/m (lw)Cp = -0.18

Wind Load:
q = 47.3*10-6(Kz*Kzt*Kd*V2*Iw*1000) 1646.797 N/m2
Pn = q*G*Cp Windward: 1012.621 N/m2
Leeward: -251.96 N/m2
Load per meter: Unfactored
WL = LL * Smax 600 N/m
Wd = Wt. Pur + Wt. Rf*Smax 445.9927 N/m
Ww = Pn*Smax 607.5726 N/m
Wl = Pn*Smax -151.176 N/m
W cos W sin
Wd = 431.9527 N/m 111.024 N/m
WL = 581.1118 N/m 149.3621 N/m
Load Combinations: Wn Wt
1.4D 604.7338 155.4336 N/m
f1 = 0.5 1.2D + 1.6W + f1L 1781.015 207.9098 N/m
1.2D + 1.6L + 0.8W 1934.18 372.2081 N/m
0.9D + 1.6W 1360.874 99.9216 N/m
1.4D + 1.7L 1592.624 409.3491 N/m
Use Largest Value!
Design Moments:
Mn = Wn*L2/8 2961.714 N.m
Mt = Wt*L2/8 626.8159 N.m
Required Section Modulus:
Sx = Mn*1000/Fb 19903.99 mm3
Sy = Mt*1000/Fb 4212.472 mm3

Actual Section:
LC 125 x 50 x 15 x 3.0 Actual Sx = 25500 mm3
Actual Sy = 6000 mm3
Flexural Capacity:
Mx = Sx(Fb)/1000 3794.4 N.m
My = Sy(Fb)/1000 892.8 N.m

Adopt LC 125 x 50 x 15 x 3.0