Load Calculation: 1. Roof Slab

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

P-4

Load calculation

1. Roof slab :-
a) S/W of 100 thick R.C.C. slab= 0.1 X 25 = 2.5 kn/sqm
b) Floor finish (av.)100 thick L.T.= 0.1 X 18 = 1.8 kn/sqm
c) Ceiling plaster 0.3 kn/sqm
d) Live load 1.5 kn/sqm

6.1 kn/sqm

2. Intermediate floor slab :-


a) S/W of 100 thick R.C.C. slab= 0.1 X 25 = 2.5 kn/sqm
b) Floor finish andceiling plaster 1 kn/sqm
c) Load from proposed light partition walls 1 kn/sqm
d) Live load 2 kn/sqm

6.5 kn/sqm

3. Staircase slab :-
a) S/W of (av.) 200 thick R.C.C. slab= 0.2 X 25 = 5 kn/sqm
b) Floor finish andceiling plaster 1 kn/sqm
c) Live load 3 kn/sqm

9 kn/sqm

4. S/W of beam :- Assumed section 250x400


a) S/W of beam rib= 0.25 X 0.3 X 25 = 1.875

5. S/W of column :- Assumed section 250x400


a) S/W of column= 0.25 X 0.4 X 25 = 2.5
S/W of column in a floor = ` 2.5 X 2.5 = 6.25 kn/floor
Total S/W of col. For 5-storied building 6.25 X 5 = 31.25 kn

6. Brick wall load :- Height of Bk. Wall = 2.85 - 0.35 = 2.5


a) 200 thick brick wall= 0.8 X 0.2 X 2.5 X 20 = 8
b) 125 thick brick wall= 0.9 X 0.125 X 2.5 X 20 = 5.625
c) 75 thick brick wall= 0.9 X 0.075 X 2.5 X 20 = 3.375
d) 125 thick parapetwall= 1 X 0.125 X 1 X 20 = 2.5
(1.0m height)