Sydem Venturi

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

PRACTICE SHEET

EXPERIMENT OF VENTURIMETER
OBSERVATIONS
A= CS
a=
S1 =
S2 =
OBSERVATION AND CALCULATION TABLE

Manometer time taken manometer water head across


difference in for 10 leter difference in the manometer H= actual discharge 0.01 /
Sr. No cm of water meters (h) h(S2- S1) time in seconds m3/ sec
1 0.7 39.69 0.007 0.0882 0.0002519526
2 32 0.1386 0.0003125
3 33 0.2016 0.0003030303
4 30 0.252 0.0003333333
5 25 0.3024 0.0004
6 22 0.315 0.0004545455

Qact
0.0005
0.00045
0.0004
0.00035
0.0003
0.00025
0.0002
0.00015
0.0001
0.00005
0
1 2 3 4

G4*G5*(SQRT(2*9.81*E11))/SQRT((P
METER

0.000363 m2
0.000176 m2
1
13.6

Coefficient of
Theoretical discharge Qth= discharge Cd=
A*a(2 g*H)0.5/(A2-a2)0.5 Qact/ Qth Avg Cd
0.0002647207 0.951767783
0.000331845 0.9417048302
0.0004002201 0.7571591722
0.0004474597 0.7449461266
0.0004901675 0.8160475954
0.0005002751 0.9085910066 0.853369

Qact

2 3 4 5 6

11))/SQRT((POWER(G4,2)-(POWER(G5,2))))
G5,2))))

You might also like