2017

Ducted & Ductless


Single Phase Inverter
Single Phase VRV
& Three Phase VRV
Comfort Systems

UNITED REFRIGERATION - CORPORATE HEADQUARTERS


11401 ROOSEVELT BOULEVARD
PHILADELPHIA, PA 19154
Revision 1, April 1, 2017 PHONE: (888) 578-9100 www.uri.com
Table of Contents
Installation Kits......................................................................................................................................... 1
URHVAC Dealer Program.......................................................................................................................... 3
URHVAC Dealer Program Commercial Financing..................................................................................... 4
URHVAC Dealer Program Residential Financing...................................................................................... 5
URHVAC Dealer Program Residential Extended Services Plans............................................................... 6
Key Features.............................................................................................................................................. 7
Regional Standards................................................................................................................................... 9
Residential System Features by Model.................................................................................................... 10
19 Series A/C & HP Single Zone Wall Mount 09 - 24 Up to 19 SEER....................... 11
LV Series HP Single Zone Wall Mount 09 - 12 Up to 24.5 SEER.................... 13
LV Series HP Single Zone DC Ducted 09 - 12 Up to 15 SEER....................... 15
Quaternity HP Single Zone Wall Mount 09 - 15 Up to 26 SEER....................... 17
15 Series A/C & HP Single Zone Wall Mount 09 - 24 Up to 15 SEER....................... 19
Aurora HP Single Zone Wall Mount 09 - 15 Up to 20 SEER....................... 21
Aurora HP Single Zone Console 09 - 15 Up to 20 SEER....................... 23
Vista HP Single Zone Cassette 09 - 18 Up to 20 SEER....................... 25
MXS/RMXS HP Multi Zone 18 - 48 Up to 18 SEER....................... 27
Multi Zone Indoor Units......................................................................................................................... 33
VRV IV S HP VRV System 36-60.................................................... 35
VRV IV 3 Phase HP and Heat Recovery VRV 6 - 38 Tons............................................ 37
Sky Air Features by Model........................................................................................................................ 39
FAQ A/C & HP Single Zone Wall Mount 18 - 24 Up to 18 SEER....................... 41
FTXS (LV Series) A/C & HP Single Zone Wall Mount 30 - 36 Up to 19 SEER....................... 43
FBQ A/C & HP Ducted 18 - 42 Up to 17 SEER....................... 45
FTQ HP Ducted 18 - 42 Up to 20 SEER....................... 47
FCQ A/C & HP Single Zone Cassette 18 - 42 Up to 17 SEER....................... 49
FHQ A/C & HP Single Zone Ceiling Mounted 18 - 42 Up to 18 SEER....................... 51
New Comfort Control App and Wireless Interface Adapter.................................................................... 53
Daikin ENVi Control.................................................................................................................................. 55
Control Options......................................................................................................................................... 56
BRC Control............................................................................................................................................... 57
Piping Accessories.................................................................................................................................... 59
Electrical Accessories................................................................................................................................ 60
Outdoor Unit Accessories......................................................................................................................... 61
Line Set Enclosure..................................................................................................................................... 62
Installation Tools....................................................................................................................................... 62
Condensate Management........................................................................................................................ 63
System & Condensate Pump Wiring........................................................................................................ 64
Service Tools............................................................................................................................................. 65
Training Classes......................................................................................................................................... 66
Dr Daikin Service Support......................................................................................................................... 67
Installation Kits
Wall Mount
19 Series Heat Pump 19 Series A/C
Indoor Outdoor Installation Kit Indoor Outdoor Installation Kit
FTX09NMVJU RX9NMVJU DLSKIT1 FTK09NMVJU RK09NMVJU DLSKIT1
FTX12NMVJU RX12NMVJU DLSKIT1 FTK12NMVJU RK12NMVJU DLSKIT1
FTX18NMVJU RX18NMVJU DLSKIT2 FTK18NMVJU RK18NMVJU DLSKIT2
FTX24NMVJU RX24NMVJU DLSKIT3 FTK24NMVJU RK24NMVJU DLSKIT3

LV Series Heat Pump LV Series A/C


FTXS09LVJU RXS09LVJU DLSKIT1
FTXS12LVJU RXS12LVJU DLSKIT1
FTXS15LVJU RXS15LVJU DLSKIT2
FTXS18LVJU RXS18LVJU DLSKIT2
FTXS24LVJU RXS24LVJU DLSKIT3
FTXS30LVJU RXS30LVJU DLSKIT4 FTXS30LVJU RKS30LVJU DLSKIT4
FTXS36LVJU RXS36LVJU DLSKIT4 FTXS36LVJU RKS36LVJU DLSKIT4

Quaternity Heat Pump


FTXG09GVJU RXG09GVJU DLSKIT1
FTXG12GVJU RXG12GVJU DLSKIT1
FTXG15GVJU RXG15GVJU DLSKIT1

Aurora Heat Pump


FTX09NMVJU RXL09NMVJU DLSKIT1
FTX12NMVJU RXL12NMVJU DLSKIT1
FTX15NMVJU RXL15NMVJU DLSKIT2

Sky Air Heat Pump Sky Air A/C


FAQ18PVJU RZQ18PVJU9 DLSKIT5 FAQ18PVJU RZR18PVJU DLSKIT5
FAQ24PVJU RZQ24PVJU9 DLSKIT5 FAQ24PVJU RZR24PVJU DLSKIT5

15 Series Heat Pump 15 Series A/C


FTXN09NMVJU RXN09NMVJU DLSKIT1 FTKN09NMVJU RKN09NMVJU DLSKIT1
FTXN12NMVJU RXN12NMVJU DLSKIT1 FTKN12NMVJU RKN12NMVJU DLSKIT1
FTXN18NMVJU RXN18NMVJU DLSKIT2 FTKN18NMVJU RKN18NMVJU DLSKIT2
FTXN24NMVJU RXN24NMVJU DLSKIT3 FTKN24NMVJU RKN24NMVJU DLSKIT3

Ducted
LV Series
FDXS09LVJU RXS09LVJU DLSKIT1
FDXS12LVJU RXS12LVJU DLSKIT1

Sky Air Horizontal Heat Pumps Sky Air Horizontal A/C


FBQ18PVJU RZQ18PVJU9 DLSKIT5 FBQ18PVJU RZR18PVJU DLSKIT5
FBQ24PVJU RZQ24PVJU9 DLSKIT5 FBQ24PVJU RZR24PVJU DLSKIT5
FBQ30PVJU RZQ30PVJU DLSKIT5 FBQ30PVJU RZR30PVJU DLSKIT5
FBQ36PVJU RZQ36PVJU9 DLSKIT5 FBQ36PVJU RZR36PVJU DLSKIT5
FBQ42PVJU RZQ42PVJU9 DLSKIT5 FBQ42PVJU RZR42PVJU DLSKIT5

1
Installation Kits
Sky Air Upflow / Horizontal Heat Pumps
Indoor Outdoor Installation Kit Indoor Outdoor Installation Kit
FTQ18PVJU RZQ18PVJU9 DLSKIT5
FTQ24PVJU RZQ24PVJU9 DLSKIT5
FTQ30PVJU RZQ30PVJU DLSKIT5
FTQ36PVJU RZQ36PVJU9 DLSKIT5
FTQ42PVJU RZQ42PVJU9 DLSKIT5

Console
Aurora Heat Pumps
FVXS09LVJU RXL09LVJU DLSKIT1
FVXS12LVJU RXL12LVJU DLSKIT1
FVXS15LVJU RXL15LVJU DLSKIT2

Cassettes
Vista Heat Pumps
FFQ09Q2VJU RX09QMVJU DLSKIT6
FFQ12Q2VJU RX21QMVJU DLSKIT6
FFQ15Q2VJU RX15QMVJU DLSKIT7

Sky Air Heat Pumps Sky Air A/C


FCQ18PVJU RZQ18PVJU9 DLSKIT5 FCQ18PVJU RZR18PVJU DLSKIT5
FCQ24PVJU RZQ24PVJU9 DLSKIT5 FCQ24PVJU RZR24PVJU DLSKIT5
FCQ30PVJU RZQ30PVJU DLSKIT5 FCQ30PVJU RZR30PVJU DLSKIT5
FCQ36PVJU RZQ36PVJU9 DLSKIT5 FCQ36PVJU RZR36PVJU DLSKIT5
FCQ42PVJU RZQ42PVJU9 DLSKIT5 FCQ42PVJU RZR42PVJU DLSKIT5

Ceiling Mount
Sky Air Heat Pumps Sky Air A/C
FHQ18PVJU RZQ18PVJU9 DLSKIT5 FHQ18PVJU RZR18PVJU DLSKIT5
FHQ24PVJU RZQ24PVJU9 DLSKIT5 FHQ24PVJU RZR24PVJU DLSKIT5
FHQ30PVJU RZQ30PVJU DLSKIT5 FHQ30PVJU RZR30PVJU DLSKIT5
FHQ36PVJU RZQ36PVJU9 DLSKIT5 FHQ36PVJU RZR36PVJU DLSKIT5
FHQ42PVJU RZQ42PVJU9 DLSKIT5 FHQ42PVJU RZR42PVJU DLSKIT5

Multi Zone Heat Pumps


2MXL18QMVJU DLMKIT
2MXS18NMVJU DLMKIT
3MXL24QMVJU DLMKIT
3MXS24NMVJU DLMKIT
4MXS36NMVJU DLMKIT
RMXS48LVJU DLMKIT

2
3
Commercial Project Financing
What if you could...
Bundle everything your clients needs. Including; New Energy Efficient HVAC Equipment, Duct Work,
Control Systems, Installation, and Service Contracts, into a convenient and affordable monthly payment
in less than 24 hours?
Heres how...
Partner with HKF Quote A Payment : call or go online
Request and return enrollment
HKF will email you an approval letter Bookmark www.DealerSalesCenter.com
Create a sample quote for $25,000 & email Click Platinum Partner on navigation bar
yourself Password is united
Call your dedicated relationship manager below Enter your email address, click quick quote
Know the Benefits logo
Easier overall process than a bank Enter project information, click continue
24 hour credit decisions & easy documentation Promo Code - varies, call for detail
No financials required up to $150,000 Dealer Rewards password is money
Does not show up on personal credit reports Optional: Dealer Rewards pays you up to
as debt 1% comm.
No blanket liens on company assets or property Review payments, click email button
Ownership of property not required Next click email Quote on the left side
Online application www.applyforlease.com of page
Enter your email in top box and click send
Explain the Process Check your inbox for an email from leasing@
Client receives a lease quote from Dealer or HKF horizonkeystone.com including the quote,
Client scans or faxes the application to HKS or application, and additional information
applies online at www.applyforlease.com requested
HKF notifies you and client of decision Print attachments or forward the email to
Dealer sends HKF final equipment quote your client
including tax
HKF emails the documents to the client
Client signs and returns documents to HKF To Invoice & Get Paid
HKF issues a PO to the Dealer
Dealer Installs & Returns Buyers Certificate Fax or email your Invoice & Buyers Certificate
(acceptance) It must include:
Horizon pays the Dealer within 24-48 hours of - Bill to & Ship to: Your Client, including Tax
completion (*See Invoice Instructions) * be sure ship address is equipment location
* be sure to include the Mfg., Model, Size,

1.800.606.0049
& S/N
* be sure to include terms and payment
method request ACH, Wire, or Overnight
Dial ext. 140 for Contractor Support Check (If ACH/Wire, Include Bank, Account
Name, Account #, ABA # on invoice or email
Financial Solutions provided by: us it)
Horizon Keystone Financial
105 Fairway Terrace
Mt. Laurel, NJ 08054
Phone: 800-606-0049 Corinne Beyer ext. 140
email: corinne@horizonkeystone.com
4
Residential HVAC Financing
Statistics show that a contractor who uses financing will close 30%-50% more jobs. Just as important,
the gross profit of their invoices tend to be higher than those who do not use financing. Few
homeowners put money aside dreaming of a new furnace. While many are reluctant to ask for
it, homeowners in need of a new comfort system are often looking for a way to manage a large,
unexpected expense. With FTL consumer financing, you are in a position to offer them exactly what
they need.
Supporting your HVAC business is our primary goal. FTL provides an easy to use financing tool that
offers fast approvals and competitive interest rates, making it both contractor & consumer friendly.

FTL Finance Benefits the Contractor


Choose Easy, Simple Financing
Supporting your sales efforts is a top priority. We
want financing to be a simple, stress free function of Financing Minimum Requirements
your business. See how FTL Finance differs from other Equipment with a model and serial
financing companies: number
No monthly minimums Finance services up to $5,000
Approve credit scores as low as 640 $300 minimum - $35,0000 maximum
Automated approvals Must own property where equipment
No dealer recourse or service is completed
No dealer charge for regular/ Show employment/retirement income
conventional financing Not in bankruptcy in the past 24
Same day funding months
Online training/live webinars Not in credit counseling
No credit card processing fees

FTL Finance Benefits Your Customer Go to URHVAC.com, Register Today!


While supporting your HVAC business is our #1 goal, 1. DOWNLOAD an application; provide
we also provide a quality, easy to use product for your a copy of the owners Drivers License
customer, because at the end of the day they will always and the signed contractor agreement
be YOUR customer. 2. No Bank Statements or P&L required,
Personal evaluation of their entire credit history No Credit Checks
Low interest rate AFTER the deferred interest period. 3. Submit a voided company check with
[You know not everyone pays the loan off] your first project to set up auto-deposit
Easy to read and understand documents 4. You will receive an email and mailed
No default interest rate welcome packet

1.800.981.9032
Press Option 3 for Contractor Support

5
Residential Extended Service Agreements
The Asure program provides your business with the flowing benefits:
Adds value to homeowners purchase. Provides the homeowner peace-of-mind that they have protected their
investment and guaranteed their comfort system for the terms of their agreement against unplanned repair bills.
Builds your customer base. By providing your customer with worry-free comfort, you earn your customers loyalty
and confidence, along with that of their friends and neighbors. What better way is there to grow your business?
What is covered?
Asure provides coverage on all functional parts of Daikin brand 3/4-through 5 ton, single-phase ductless HVAC
products. Coverage may be offered on equipment that has been installed within the last year. Routine maintenance
and the cost to correct failures other than those considered to be manufacturing defects are excluded from coverage.
For more information, please visit www.daikincomfort.com

Daikin Residential Extended Service Agreement (ESA) Instructions

Extended Indoor
Part Number Daikin Series Years Parts & Labor
Warranty Outdoor
EWDLVMXSI12PL I
EW D LV & MXS 12 PL
EWDLVMXSO12PL O

Extended Indoor
Part Number Daikin Series Years Parts & Labor
Warranty Outdoor
EWDKE10PL KE 15 & 19 I
EW D 10 PL
EWDKE10PL Series O

Instructions
1. You must register as an Authorized Daikin Servicer.
a. Daikin Authorized Servicer Agreement is available from your local United Refrigeration branch.
2. You must be registered as a United Refrigeration / Daikin Dealer.
3. The Dealer will complete the Extended Service Agreement / Homeowner Contract, and bring it to their United
Refrigeration branch.
a. Must be signed by the Dealer.
b. Must be signed by the Homeowner.
4. The Extended Service Agreement Homeowner Contract will be activated at URI HQ.
5. Upon Activation:
a. Daikin will send Extended Warranty Document to the homeowner.
b. United Refrigeration will invoice the dealer.

6
Key Features and Benefits*
KeyFeaturesandBenefits*
SuperiorComfortControl
IndoorUnitQuietOperation.Soundlevelsare RemoteControllerwithBacklitDisplay.
reducedby23decibels(dB)fromthelowfan FeaturesabacklitLCDandluminescentcontrol
speedforquieterandgentlerheatingand buttons,allowingforeasyviewingindimlylit
cooling. rooms.

OutdoorUnitQuietOperation.Outdoorunit HomeLeaveOperation.Selectthisenergy
soundlevelscanbereducedby3dBfortimes savingfunctionwhenleavingthehouseandthe
whenquieteroperationisneeded. airconditionerwilloperateatapreselected
temperature.Yourhomecanthenbewarmed
IntelligentEye.Theintelligenteyeisaninfrared orcooledmuchquickeruponyourreturn.Itcan
sensorwiththeabilitytosensemovementin alsobeusedtorecordyourpreferred(default)
theroom.Whenyouareintheroom,theair settings.
conditioneroperatesnormally.Ifyouleavethe
roomformorethan20minutestheair IndoorUnitOn/OffSwitch.Aconvenienton/off
conditionerautomaticallychangestoanenergy switchontheindoorunitallowsyoutostartup
savingoperation.Usingtheintelligenteye, thesystemevenifyouhavemisplacedthe
savingsofupto20%incoolingandupto30%in remotecontrolortheremotecontrolbatteries
heatingcanbeachieved. areexhausted.

AutomaticOperation.Forunattendedyear ComfortableAirflow
roundcomfort,thisfunctionallowstheunitto
automaticallyswitchbetweenheatingand
WideAngleLouvers.Smoothlycurvedwide
coolingmodesasrequired.
anglelouversprovidewideairflowcoveragefor
effectiveheatingandcoolingnomatterwhere
ProgramDryFunction.Thisgivespriorityto theindoorunitisplacedwithintheroom.
reducingthelevelofhumidityintheroom
ratherthanroomtemperature.
DualFlapSystem.Thisuniquesystemdirects
warmairtothefloorinwinterandcoolair
AutoFanSpeed.Toreduceoperatingsound acrosstheroominsummerformaximum
andpowerconsumption,thefanspeedis efficiencyandcomfort.Thelargeflapgoverns
automaticallycontrolledbythemicroprocessor airflowdirectionwhilethesmallflap(or
tosuitthecontrollersettingandprevailing diffuser)swings,producingfineaircurrentsthat
roomtemperature. helpcirculatetheairaroundtheroom.

HotStart.Whentheheatingoperationstartsor ComfortableMode.Thenewflapchangesthe
whentheunitchangesfromcoolingtoheating deliveryangletohorizontalforcoolingand
thereisnocolddraftreleasedintotheroom. verticalforheatingoperation,topreventcold
orwarmairfromblowingdirectlyontoyour
LifestyleConvenience body.

EconoMode. Limitsthemaximumoperating VerticalAutoSwing(upanddown).The


currentandpowerconsumptionoftheoutdoor verticalautoswingautomaticallysweepstheair
unitbyapproximately30%duringstartup.This acrosstheroominanupanddownmotion.
savesenergyandreducestheloadonthe Whentheunitisswitchedoff,thelouversclose
electricalcircuitwhenmultipleelectrical automatically.
devicesareusedsimultaneously.
HorizontalAutoSwing(leftandright).
PowerfulOperation.PushingthePOWERFUL Automaticallymovestoensureaneven
buttonontheremotecontrolgivesyouaboost distributionofairthroughoutaroom.
incoolingorheatingpowerfora20minute
period,eveniftheunitisalreadyoperatingat 3DAirflow.Combinesverticalandhorizontal
highcapacity. autoswingtocirculatecool/warmairtothe
cornersoflargespaces.
*Pleaserefertoindividual productforavailability.(pg7)
4

7
WorryFree Timers
AutoRestart.Theunitmemorizesthe 24HourOn/OffTimer.Thetimercanbepreset
operationmode,airflowandtemperature tostartandstoptheairconditioneratanytime
settings.Shouldtherebeapowerfailurewhen withina24hourperiod.Oncethetimesareset,
theunitisinoperation,itwillautomatically theairconditionercanbeoperated
returntothesameoperatingconditionswhen bysimplypressingtheONorOFFtimerbuttons.
thepowerisrestored.
WeeklyTimer.Theweeklytimerfunction
SelfDiagnosis.Intheeventthataproblem makesiteasytoenteruptofoursettingsper
developswiththeunit,malfunctioncodescan dayforeachdayoftheweek.Theweeklytimer
bedisplayedontheliquidcrystalpanelofthe functionnotonlyallowsyoutoprogramonand
remotecontrolforfastandeasyfaultdiagnosis. offtime,butalsothedesiredtemperature.

AntiCorrosion.Thespecialanticorrosion NightSetMode.ThroughtheuseoftheTimer
coatingontheoutdoorunitheatexchanger OFFCircuit,thepresetroomtemperature
ensuresgreaterresistancetosaltdamageand gentlyrisesincoolingorfallsinheatingbefore
atmosphericcorrosion. theunitstops.Thisenergysavingfeatureallows
youtosleepcomfortablywithoutfeelinga
HealthyandClean suddenchangeintheroomtemperature,while
atthesametimesavingenergy.
AirPurifyingFilterwithPhotocatalytic
DeodorizingFunction.Thiscombination KeepingWarm
operatesasahighlyeffectiveunit.Thefilter
attractsmicroscopic particlesthatcancarry QuickWarmingFunction.Preheatsthe
bacteriaandviruses. The filter is effective compressortoshortenthetimerequiredto
forapproximatelythreeyearsifperiodic dischargewarmair.
maintenanceisperformed.
AutomaticDefrosting.Sensorperforms
TitaniumApatitePhotocatalyticAirPurifying automaticdefrostingoftheoutdoorheat
Filter.Thisfiltercombinestheairpurifyingfilter exchangerifnecessary,ensuringoptimum
andtitaniumapatitephotocatalytic deodorizing heatingperformance.
filterinasinglehighlyeffectiveunit.Thefilter
trapsmicroscopicparticles,decomposesodors Warranty Chart
andevenadsorbsanddeactivatesbacteriaand
viruses.Itlastsforthreeyearswithout Residential Residential
Warranty Warranty
replacementifwashedonceeverysixmonths.
(Base)* (Registration Commercial*
required)*
MoldProofAirFilter.Theprefilternetis 19 Series 5 Years 12 Years 5 Years
impregnatedwithasafe,colorlessandodorless LV Series 5 Years 12 Years 5 Years
moldpreventative.Thisrendersthefilter
virtuallyimmunetomold. Quaternity 5 Years 12 Years 5 Years
Aurora 5 Years 12 Years 5 Years
WipeCleanFlatPanel.Theflatpanelmodels Vista 5 Years 12 Years 5 Years
canbecleanedwithonlythesinglepassofa Multi Zone 5 Years 12 Years 5 Years
clothacrosstheirsmoothsurface.Theflatpanel 15 Series 5 Years 10 Years 5 Years
canalsobeeasilyremovedformorethorough
cleaning.
VRV-S 10 Years 10 Years
Sky Air 10 Years 10 Years
VRV 3 Phase 10 Years 10 Years
* When properly installed per Daikin specifications &
instructions, by a trained, licensed & insured HVAC contractor.

* Features may not be available on all models. Refer to page 10 for a list of features by model on wireless remote control
products. Refer to page 40 for a list of features by model on Sky Air control products. 5

8
2015 Single Phase Regional Standards
Type North South Southwest
14 SEER / 12.2 EER (<45k btu/h)
Split A/C 13 SEER 14 SEER
14 SEER / 11.7 EER (45k btu/h)
Split Heat Pumps 14 SEER / 8.2 HSPF

13 SEER

Split System
< 45,000 BTU 45,000 BTU
14 SEER
12.2 EER
14 SEER
11.7 EER
14 SEER Air Conditioning

14 SEER Split System


8.2 HSPF
Heat Pumps

9
Split System Features
Single Split
Multi-Split
15 19 LV FFQ Q
Type
Cool Heat Cool Heat Heat Heat Heat Heat Heat Pump
Only Pump Only Pump Pump Pump Pump Pump

FTKN_NMVJU

FTXN_NMVJU

FTK_NMVJ

FTX_NMVJ
Models

CDXS_LV
FDXS_LV

FDXS_LV

CTXS_LV
FTXS_LV

FTXS_LV
FTXG_H

CTXS_H
FFQ_LV

CTXG
FFQ
Regional Compliance NS ALL NS ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL

Warranty 10 10 10 10 12 12 12 12 12 12 12 12 12 12 12

Pulse Amplitude Modulation


Power Airflow Dual Flaps
Comfortable Airflow

Wide Angle Louvers


Vertical Auto Swing (up and down)
Horizontal Auto Swing (left and right)
3 D Airflow
Comfortable Mode
Indoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Comfort Control

Intelligent Eye
Automatic Operation
Program Dry Function
Auto Fan Speed
Hot Start
Mold Proof Air Filter
Healthy and Clean

Air Purifying Filter with Photocatalytic


Deodorizing Function
Titanium Apatite Photocatalytic
Air Purifying Function
Flash Streamer
Wipe clean Flat Panel
Standby Electricity Saving
Econo Mode
Powerful Operation
Lifestyle

Remote Controller with backlit display


LCD Wireless Remote Control
Home Leave Operation
Indoor Unit On/Off Timer
24 Hour On/Off Timer
Timers

Weekly Timer
Night Set Mode
Auto Restart after Power Failure
Worry Free

Self Diagnosis with Digital Display


Anticorrosion Treatment of Outdoor
Heat Exchanger Fin
10
19 SERIES WALL MOUNT
Up to 19 SEER
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Remote Control with Inverter Technology
Vertical Louver Auto Swing Backlit Display Included PAM Control
Comfortable Mode Night Set-Back Function Econo Mode
Optional Wifi Control
Powerful Mode Indoor Unit On/Off Switch 24 Hour On/Off Timer See Page 53
Automatic Fan Speed Wipe Clean Indoor Unit Stand-by Electric Savings
Dry Mode Self Diagnostic Control
Mold Proof Air Filter Auto Restart Durability
Titanium Apatite Air Purifier Anti-Corrosion Coating
Quiet Operation Indoor Unit Pre Charged Outdoor Units Daikin Swing Compressor
Hot Start & Auto Changeover (33) Adjust Charge
(Heat Pump) .22 oz/ft
Low ambient
cooling to 0F
Timely with optional
19 Series is Wind Baffle*
registration
available in
is required in
all regions
most states

Single Zone Wall Mount Cooling Only

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FTK09NMVJU RK09NMVJU 19 12.5 ----- ----- 9,000 ----- DH-16 MSLS1438144**-1/2 65 49


FTK12NMVJU RK12NMVJU 19 12.5 ----- ----- 10,900 ----- DH-16 MSLS1438144**-1/2 65 49
FTK18NMVJU RK18NMVJU 18 12.5 ----- ----- 18,000 ----- DH-16 MSLS1412144**-1/2 98 65
FTK24NMVJU RK24NMVJU 18 12.5 ----- ----- 21,200 ----- DH-16 MSLS1458144**-1/2 98 65

Single Zone Wall Mount Heat Pumps


FTX09NMVJU RX09NMVJU 19 12.5 9 4.1 9,000 10,000 DH-16 MSLS1438144**-1/2 65 49
FTX12NMVJU RX12NMVJU 19 12.5 9 3.8 12,000 13,500 DH-16 MSLS1438144**-1/2 65 49
FTX18NMVJU RX18NMVJU 18 12.5 9 3.6 17,100 21,600 DH-16 MSLS1412144**-1/2 98 65
FTX24NMVJU RX24NMVJU 18 12.5 9 3.5 21,200 24,000 DH-16 MSLS1458144**-1/2 98 65

Go to Page 43 for larger capacities


*Low ambient cooling instructions:
Cut jumper J6 on the out door unit main PCB
If metal clad wire is required, order the line set and wire separately. Example: MSLS143850-1/2 + 58340803

11
19 SERIES WALL MOUNT
Specifications
19 Series Wall Mount Indoor Specifications
Model FT*09NMVJU FT*12NMVJU FT*18NMVJU FT*24NMVJU
Cooling Capacity 4400 - 10,200 4400 - 13,300 5500 - 20,000 5500 - 24,000
Heating Capacity 4400 - 13,000 4400 - 16,400 5500 - 24,000 5800 - 27,600
Moisture Removal Quarts/Hour 0.325 0.45 1.025 1.2
Air Flow wet 417/297/244/141 434/311/247/145 713/579/448/403 713/579/512/403
Air Flow dry 403/328/251/215 413/321/258/219 745/604/470/420 745/604/470/420
Sound Pressure Cooling 43/36/30/19 45/37/30/19 49/44/38/33 53/45/39/34
Sound Pressure Heating 43/36/29/25 45/37/30/26 49/42/37/33 53/43/37/34
Dimensions 11 1/4 x 30 5/8 x 8 3/4 11 5/8 x 39 x 10 3/8
Weight 18 lb 26 lb
19 Series Outdoor Specifications
Model R*09NMVJU R*12NMVJU R*18NMVJU R*24NMVJU
Sound Pressure Cooling 46 49 54 55
Sound Pressure Heating 48 49 54 55
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling Low 14 - 115 Degrees F
Ambient*
Operating Range Cooling Low 0 - 115 Degrees F
Ambient with Wind Baffle*
Operating Range Heating 5 - 75 Degrees F
Operating Range Heating with -4 - 75 Degrees F
Drain Pan Heater**
Maximum Over Current
15A 20A
Protection
Dimensions 21 5/8 x 26 1/2 x 11 1/8 29 x 34 1/4 x 12 5/8
Weight 55 lb 60 lb 97 lb 108 lb

Accessories Control Options Low Ambient Cooling Options


UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control KPW937E4 Wind Baffle RK/RX 09-12
BR440 Wall Bracket DACATS11 Daikin Envi Wifi Control KPW063A4 Wind Baffle RK/RX 18-24
X85003 Condensate Pump 09-18 BRP072A43 Wifi Interface Low Ambient Heating Options
X87721 Condensate Pump 24+ KRP067A41 Wired Control Adapter 09 & 12 KEH067A41E Drain Pan Heater RX 09-12
T18016 Pump Enclosure KRP980B2 Wired Control Adapter 18 & 24 KEH063A4E Drain Pan Heater RX 18-24
KRP928BB2S DIII Net Interface
AG3000 Intermatic Surge Protector

Back & Side Wire Grille Parts & Labor Plan


KKG067A41 Back Wire Grille for 19 Series 09-12 EWDLVMXSO12PL Transferrable Extended Service Plan
KKG063A42 Back Wire Grille for 19 Series 18-24 EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor
KKG063A43 Side Wire Grille for 19 Series 18-24

More installation supplies & accessories, starting on page 59

12
LV SERIES WALL MOUNT
Up to 24.5 SEER
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Remote Control with Inverter Technology
Comfortable Mode Backlit Display Included PAM Control
Powerful Mode Night Set-Back Function Econo Mode
Optional Wifi
Automatic Fan Speed Indoor Unit On/Off Switch 24 Hour On/Off Timer Page 51
Dry Mode Wipe Clean Indoor Unit Intelligent Eye
Mold Proof Air Filter Self Diagnostic Control Stand-by Electric Savings
Titanium Apatite Air Purifier Auto Restart Weekly Timer
Quiet Operation Indoor & Outdoor Pre-Charged Condensing
Hot Start & Auto Changeover Durability
Units (33) Adjust Charge
3D Airflow Anti-Corrosion Coating
.22 oz/ft
Power Dual Flaps Daikin Swing Compressor Low ambient
cooling to 0F
with optional
Timely Wind Baffle*
LV Series is
registration
available in
is required in
all regions
most states

Single Zone Wall Mount Heat Pumps 20+ SEER

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FTXS09LVJU RXS09LVJU 24.5 15.3 12.5 4.5 9,000 9,000 DH-16 MSLS1438144**-1/2 65 47
FTXS12LVJU RXS12LVJU 23.0 12.8 12.5 4.4 12,000 14,000 DH-16 MSLS1438144**-1/2 65 47
FTXS15LVJU RXS15LVJU 20.6 14.4 11.6 4.0 15,000 15,000 DH-16 MSLS1412144**-1/2 98 65
FTXS18LVJU RXS18LVJU 20.3 12.7 11.0 3.7 18,000 18,000 DH-16 MSLS1412144**-1/2 98 65
FTXS24LVJU RXS24LVJU 20.0 12.5 10.6 3.4 21,500 25,400 DH-16 MSLS1458144**-1/2 98 65

Go to Page 43 for larger capacities


*Low ambient cooling instructions:
09-12: Cut jumper J4 on outdoor unit main PCB
15-18: Cut jumper J6 on outdoor unit main PCB
24-36: Turn On dip switch B on SW4 on outdoor unit main PCB
If metal clad wire is required, order the line set and wire separately. Example: MSLS143850-1/2 + 58340803

13
LV SERIES WALL MOUNT
Specifications
LV Series Wall Mount Indoor Specifications
Model FTXS09LVJU FTXS12LLJU FTXS15LVJU FTXS18LVJU FTXS24LVJU
Cooling Capacity 4400 - 10,600 4800 - 13,800 5800 - 18,000 5800 - 21,600 7800 - 25,800
Heating Capacity 4400 - 15,600 4800 - 18,000 5800 - 22,300 5800 - 26,700 7800 - 31,400
Moisture Removal Gallons/Hour 0.3 0.5 0.8 1 1.2
Air Flow wet 381/279/194/145 403/307/205/155 568/477/385/360 583/484/385/360 643/494/350/328
Air Flow dry 420/321/233/219 438/335/240/212 593/505/417/371 625/526/431/399 699/572/445/403
Sound Pressure Cooling 41/33/25/22 45/37/29/23 45/40/35/32 46/41/36/33 51/42/37/34
Sound Pressure Heating 42/35/28/25 45/39/29/26 43/38/33/30 45/40/35/32 48/42/37/34
Dimensions 11 5/8 x 31 1/2 x 8 7/16 13 3/8 x 41 5/16 x 9 3/4
Weight 20 lb 22 lb 31 lb

LV Series Outdoor Specifications


Model RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU
Sound Pressure Cooling 47/43 49/44 47/44 49/46 52/49
Sound Pressure Heating 48/44 49/45 48/45 49/46 52/49
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling Low 14 - 115 Degrees F
Ambient*
Operating Range Cooling Low 0 - 115 Degrees F
Ambient with Wind Baffle*
Operating Range Heating 5 - 77 Degrees F
Maximum Over Current 15A 20A
Protection
Dimensions 21 5/8 x 30 1/8 x 11 1/4 26 15/16 x 32 1/2 x 11 13/16 30 5/16 X 35 7/16 X 12 5/8
Weight 75 lb 104 lb 159 lb
Weight 55 lb 60 lb 97 lb 108 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control For Low Ambient Cooling Applications
BR440 Wall Bracket DACATS11 Daikin Envi Wifi Control KPW937E4 RXS 09 & 12
X85003 Condensate Pump 09-18 BRP072A43 Wifi Interface KPW945E4 RXS 15 - 24
X87721 Condensate Pump 24+ KRP928BB2S DIII Net Interface
T18016 Pump Enclosure AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59 Parts & Labor Plan
EWDLVMXSO12PL Transferrable Extended Service Plan
EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor

14
LV SERIES DC Ducted
15 SEER
Comfort Convenience Efficiency
Powerful Mode Remote Control with Inverter Technology
Automatic Fan Speed Backlit Display Included PAM Control
Dry Mode Night Set-Back Function Econo Mode
Mold Proof Air Filter Self Diagnostic Control 24 Hour On/Off Timer Optional Wifi
Page 53
Quiet Operation Outdoor Unit Auto Restart Stand-by Electric Savings
Hot Start & Auto Changeover Weekly Timer
Pre Charged Condensing
Units (33) Adjust Charge Durability
.22 oz/ft Anti-Corrosion Coating
Daikin Swing Compressor

Timely
LV Series is Low ambient
registration
available in cooling to 0F
is required in
all regions with optional
most states
Wind Baffle*

DC Ducted Heat Pumps

Cooling Heating Max Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h E.S.P. w/ 14/4 Wire Length Height

FDXS09LVJU RXS09LVJU 15.1 11.2 10.3 3.5 8,500 11,500 .12 3/4 PVC MSLS1438144**-1/2 65 49
FDXS12LVJU RXS12LVJU 15.5 9.1 10.4 3.5 10,000 11,500 .12 3/4 PVC MSLS1438144**-1/2 65 49

Go to Page 45 for larger capacities


*Low ambient cooling instructions:
Cut jumper J4 on outdoor unit main PCB
If metal clad wire is required, order the line set and wire separately. Example: MSLS143850-1/2 + 58340803

15
LV SERIES DC Ducted
Specifications
LV Series Ducted Indoor Specifications
Model FDXS09LVJU FDXS12LLJU
Max ESP 0.12' wc
Condensate Drain 3/4"
Cooling Capacity 4400 - 8,500 4800 - 11,500
Heating Capacity 4400 - 10,000 4800 - 11,500
Moisture Removal Gallons/Hour 0.625 1
Air Flow wet 305/280/260/235 305/280/260/235
Air Flow dry 305/280/260/235 305/280/260/235
Sound Pressure Cooling 35/33/31 35/33/31
Sound Pressure Heating 35/33/31 35/33/31
Dimensions 7 7/8 x 27 9/16 x 24 7/16
Weight 20 lb 22 lb

LV Series Outdoor Specifications


Model RXS09LVJU RXS12LVJU
Sound Pressure Cooling 47/43 49/44
Sound Pressure Heating 48/44 49/45
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling Low 14 - 115 Degrees F
Ambient*
Operating Range Cooling Low 0 - 115 Degrees F
Ambient with Wind Baffle*
Operating Range Heating 5 - 77 Degrees F
Maximum Over Current 15A
Protection
Dimensions 21 5/8 x 30 1/8 x 11 1/4
Weight 75 lb

Accessories Control Options Wind Baffles


For Low Ambient Cooling Applications
UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control
KPW937E4 RXS 09 & 12
BR440 Wall Bracket DACATS11 Daikin Envi Wifi Control
X85003 Condensate Pump BRP072A43 Wifi Interface
DP30X30L Aux Drain Pan KRP928BB2S DIII Net Interface
AG1201+ Aux Drain Pan Switch AG3000 Intermatic Surge Protector

Parts & Labor Plan


More installation supplies & accessories, starting on page 59 EWDLVMXSO12PL Transferrable Extended Service Plan
Larger ducted models are available, see page 45 EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor

16
QUATERNITY SERIES WALL MOUNT
Up to 26 SEER
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Wireless Remote Control Inverter Technology
Comfortable Mode Included PAM Control
Powerful Mode Night Set-Back Function 24 Hour On/Off Timer
Automatic Fan Speed Indoor Unit On/Off Switch
Dry Operation Wipe Clean Indoor Unit Durability
Mold Proof Air Filter Self Diagnostic Control Anti-Corrosion Coating
Titanium Apatite Air Purifier Auto Restart Daikin Swing Compressor
Quiet Operation Indoor Unit Temperature and Humidity
Cooling Breeze Display
Comfort Sleep Countdown Off Timer
Flash Stream Air Purifier Child Proof Lock
Hot Start & Auto Changeover Multi-Colored Indicator
Power Air Flow Dual Flaps Filter Cleaning Indicator
3D Airflow
Pre-Charged Condensing
Units (33) Adjust
Charge .22 oz/ft

Timely
Quaternity Low ambient
registration
Series is cooling to 14F
is required in
available in
most states
all regions

Single Zone Wall Mount Quaternity Heat Pumps Up to 26 SEER

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FTXG09HVJU RXG09HVJU 26.1 15.8 11 4.5 9,000 12,000 DH-16 MSLS1438144**-1/2 32 26


FTXG12HVJU RXG12HVJU 24.2 14.0 10.55 4.0 12,000 16,000 DH-16 MSLS1438144**-1/2 32 26
FTXG15HVJU RXG15HVJU 21.0 12.9 10 4.0 15,000 18,000 DH-16 MSLS1438144**-1/2 32 26
If metal clad wire is required, order the line set and wire separately. Example: MSLS143850-1/2 + 58340803

FLASH STREAMER

Opposing polar plate

Electrostatic dust Titanium Apatite


Streamer deodorizing
Plasma ionizer Photocatalytic Filter
catalyst

17
QUATERNITY SERIES WALL MOUNT
Specifications
Quaternity Wall Mount Indoor Specifications
Model FTXG09LVJU FTXG12LLJU FTXG15LVJU
Cooling Capacity 5300 - 12,300 5300 - 15,700 5300 - 18,000
Heating Capacity 4400 - 18,000 4400 - 19,100 4400 - 21,200
Moisture Removal Gallons/Hour 0.4 0.5 0.6
Air Flow wet 420/325/230 459/346/240 487/371/258
Air Flow dry 438/346/258 470/367/272 494/392/293
Sound Pressure Cooling 42/33/26 43/35/27 45/37/29
Sound Pressure Heating 42/35/28 43/36/29 44/38/31
Warms air to
Dimensions 12 x 35 1/32 x 8 7/32 regulate temperature

Weight 31 lb Chills air to


remove moisture

Quaternity Outdoor Specifications


Model RXG09LVJU RXG12LVJU RXG15LVJU Comfortable air at just
the right temperature
and humidity level
Sound Pressure Cooling 46 49 50
Sound Pressure Heating 46 48 50
Operating Range Cooling 14 - 109
Operating Range Heating -4 - 75
Maximum Over Current 15A
Protection
Dimensions 22 3/8 x 35 1/32 x 11 7/32
Weight 99 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control For Low Ambient Cooling Applications
BR440 Wall Bracket KRP928BB2S DIII Net Interface KPW937E4 RXG 09 - 15
X85003 Condensate Pump AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59 Parts & Labor Plan
EWDLVMXSO12PL Transferrable Extended Service Plan
EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor

18
15 SERIES WALL MOUNT
15 SEER
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Remote Control Included Inverter Technology
Optional Wifi Control
Vertical Louver Auto Swing Night Set-Back PAM Control See Page 53
Comfortable Mode Indoor Unit On/Off Switch Econo Mode
Powerful Mode Wipe Clean Indoor Unit 24 Hour On/Off Timer
Automatic Fan Speed Self Diagnostic Control Stand-by Electric Savings
Dry Mode Auto Restart
Mold Proof Air Filter Durability
Pre Charged Outdoor Units Anti-Corrosion Coating This model is not
Quiet Operation Indoor Unit
(33) Adjust Charge .22 oz/ft Daikin Swing Compressor suitable for low
Hot Start & Auto Changeover ambient cooling
(Heat Pump) applications

Timely 15 Series 15 Series


registration A/C models are Heat Pumps are
is required in not available in Available in all
most states the Southwest regions

Single Zone Wall Mount Cooling Only

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FTKN09NMVJU RKN09NMVJU 15 10.4 ----- ----- 9,000 ----- DH-16 MSLS1438144**-1/2 49 39


FTKN12NMVJU RKN12NMVJU 15 10.5 ----- ----- 12,000 ----- DH-16 MSLS1438144**-1/2 49 39
FTKN18NMVJU RKN18NMVJU 15 12.2 ----- ----- 17,100 ----- DH-16 MSLS1412144**-1/2 98 65
FTKN24NMVJU RKN24NMVJU 15 9.2 ----- ----- 22,000 ----- DH-16 MSLS1458144**-1/2 98 65

Single Zone Wall Mount Heat Pumps


FTXN09NMVJU RXN09NMVJU 15 10.4 8.2 3.9 9,000 9,000 DH-16 MSLS1438144**-1/2 49 39
FTXN12NMVJU RXN12NMVJU 15 10.5 8.2 3.9 12,000 12,000 DH-16 MSLS1438144**-1/2 49 39
FTXN18NMVJU RXN18NMVJU 15 12.2 8.2 3.8 17,100 18,000 DH-16 MSLS1412144**-1/2 98 65
FTXN24NMVJU RXN24NMVJU 15 9.2 8.2 3.6 22,000 22,000 DH-16 MSLS1458144**-1/2 98 65
Go to Page 43 for larger capacities
**25 & 50 line sets available
If metal clad wire is required, order your line set and wire separately. Example: MSLS143850-1/2 + 58340803

19
15 SERIES WALL MOUNT
Specifications
15 Series Wall Mount Indoor Specifications
Model FT*N09NMVJU FT*N12NMVJU FT*N18NMVJU FT*N24NMVJU
Cooling Capacity 4400 - 10,200 4400 - 13,000 5100 - 18,000 5100 - 23,000
Heating Capacity 4400 - 10,000 4400 - 14,000 5100 - 19,100 5100 - 25,400
Moisture Removal Gallons/Hour 0.325 0.45 1.025 1.2
Air Flow wet 403/286/219/145 424/300/247/141 713/579/455/417 713/579/491/417
Air Flow dry 406/318/247/215 413/321/247/212 660/568/470/420 745/604/470/420
Sound Pressure Cooling 43/35/27/19 44/36/30/19 48/44/38/33 51/45/39/34
Sound Pressure Heating 43/35/28/25 44/36/29/18 48/42/37/33 41/43/37/34
Dimensions 11 1/4 x 30 5/8 x 8 3/4 11 5/8 x 39 x 10 3/8
Weight 18 lb 26 lb

15 Series Outdoor Specifications


Model R*N09NMVJU R*N12NMVJU R*N18NMVJU R*N24NMVJU
Sound Pressure Cooling 46 49 54 55
Sound Pressure Heating 48 49 54 55
Operating Range Cooling 50 - 115 Degrees F
Operating Range Heating 5 - 75 Degrees F
Maximum Over Current Protection 15A 20A
Dimensions 21 5/8 x 26 1/2 x 11 1/8 29 x 34 1/4 x 12 5/8
Weight 53 lb 97 lb

Accessories Control Options


UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control
BR440 Wall Bracket DACATS11 Daikin Envi Wifi Control
X85003 Condensate Pump 09-18 BRP072A43 Wifi Interface
X87721 Condensate Pump 24+ KRP067A41 Wired Control Adapter 09 & 12
T18016 Pump Enclosure KRP980B2 Wired Control Adapter 18 & 24
KRP928BB2S DIII Net Interface
AG3000 Intermatic Surge Protector

Back & Side Wire Grille Parts & Labor Plan


KKG067A41 Back Wire Grille for 15 Series 09-12 EWDKEO10PL Transferrable Extended Service Plan
KKG063A42 Back Wire Grille for 15 Series 18-24 EWDEI10PL 6-10 Year Parts, 10 Year Labor
KKG063A43 Side Wire Grille for 15 Series 18-24
More installation supplies & accessories, starting on page 59

20
AURORA ENHANCED CAPACITY
WALL MOUNT
Up to 20 SEER
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Remote Control with Inverter Technology
Vertical Louver Auto Swing Backlit Display Included PAM Control
Comfortable Mode Night Set-Back Function Econo Mode
Optional Wifi Control
Powerful Mode Indoor Unit On/Off Switch 24 Hour On/Off Timer See Page 53
Automatic Fan Speed Wipe Clean Indoor Unit Stand-by Electric Savings
Dry Mode Self Diagnostic Control
Mold Proof Air Filter Auto Restart Durability
Titanium Apatite Air Purifier Anti-Corrosion Coating
Quiet Operation Indoor Unit Pre Charged Outdoor Units Daikin Swing Compressor
Hot Start & Auto Changeover (33) Adjust Charge
(Heat Pump) .22 oz/ft

Timely
This model is
registration
available in
is required in
all regions
most states

Up to 100% Rated Heating Capacity to 5F


Up to 100% Rated Cooling Capacity to 104F
Single Zone Wall Mount Heat Pumps

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FTX09NMVJU RXL09QMVJU 20 12.5 12.5 4.2 9,000 10,900 DH-16 MSLS1438144**-1/2 65 49


FTX12NMVJU RXL12QMVJU 20 12.5 12.0 3.9 12,000 14,300 DH-16 MSLS1438144**-1/2 65 49
FTX15NMVJU RXL15QMVJU 20 13.0 12.5 4.0 15,000 18,300 DH-16 MSLS1412144**-1/2 98 65

More installation supplies & accessories, starting on page 59


If metal clad wire is required, order your line set and wire separately. Example: MSLS143850-1/2 + 58340803

21
AURORA ENHANCED CAPACITY WALL MOUNT
Specifications
Wall Mount Indoor Specifications
Model FTX09NMVJU FTX12NMVJU FTX15NMVJU
Cooling Capacity 4400 - 10,900 4400 - 13,300 5800 - 18,400
Heating Capacity 4400 - 16,000 4400 - 18,800 5800 - 24,600
Moisture Removal Quarts/Hour 0.325 0.45 0.63
Air Flow wet 417/297/244/141 434/311/247/145 593/505/431/367
Air Flow dry 403/328/251/215 413/321/258/219 653/554/470/399
Sound Pressure Cooling 43/36/30/19 45/37/30/19 45/41/36/33
Sound Pressure Heating 43/36/29/25 45/37/30/26 45/41/36/34
Dimensions 11 1/4 x 30 5/8 x 8 3/4 11 5/8 x 39 x 10 3/8
Weight 18 lb 26 lb

Enhanced Capacity Outdoor Unit


Model RXL09NMVJU RXL12NMVJU RXL15NMVJU
Sound Pressure Cooling 49 50 50
Sound Pressure Heating 49 50 55
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling 14 - 115 Degrees F
Low Ambient*
Operating Range Cooling Low -4 - 115 Degrees F
Ambient with Wind Baffle*
Operating Range Heating 5 - 75 Degrees F
Operating Range Heating -13 - 75 Degrees F
with Drain Pan Heater**
Maximum Over Current 15A
Protection
Dimensions 21 5/8 x 26 1/2 x 11 1/8 28 15/16 x 34 1/4 x 12 5/8
Weight 60 lb 70 lb 108 lb

Accessories Control Options Wind Baffle For Low Ambient Cooling Applications
UL16x36 Condenser Pad BRP072A43 Wifi Interface KPW937E4 RXL09-15
BR440 Wall Bracket DACATS11 Daikin Envi Wifi Control
X85003 Condensate Pump 09-18 BRC944B2A08 Convert to Wired Control
KRP067A41 Wire Control Adapter 09 & 12
KRP980B2 Wire Control Adapter 18 & 24
AG3000 Intermatic Surge Protector

Parts & Labor Plan Snow Protection Hood


EWDLVMXSO12PL Transferrable Extended Service Plan KPS067A41 RXL09 & RXL12 - Side
EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor KPS063A41 RXL15QMVJU - Side
KPS067A42 RXL09QMVJU & RXL12QMVJU - Back
Low Ambient Heating Options
KPS063A44 RXL15QMVJU - Back
KEH067A41E Drain Pan Heater RX 09-12
KPS067A44 RXL09QMVJU & RXL12QMVJU - Discharge
KEH063A4E Drain Pan Heater RX 18-24
KPS063A47 RXL15QMVJU - Discharge
22
AURORA ENHANCED CAPACITY
FLOOR MOUNT
Up to 20 SEER
COMFORT CONVENIENCE Efficiency
Powerful Mode Remote Control with Inverter Technology
Automatic Fan Speed Backlit Display Included PAM Control
Dry Mode Night Set-Back Function Econo Mode
Optional Wifi Control
Mold Proof Air Filter Self Diagnostic Control 24 Hour On/Off Timer See Page 53
Hot Start & Auto Changeover Auto Restart
(Heat Pump) Durability
Pre Charged Outdoor Units Anti-Corrosion Coating
(33) Adjust Charge Daikin Swing Compressor
.22 oz/ft

Timely
This model is
registration
available in
is required in
all regions
most states

Up to 100% Rated Heating Capacity to 5F


Up to 100% Rated Cooling Capacity to 104F
Single Zone Wall Mount Heat Pumps

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ 14/4 Wire Length Height

FVXS09NVJU RXL09QMVJU 20 12.5 12.5 4.2 9,000 10,900 DH-16 MSLS1438144**-1/2 65 49


FVXS12NVJU RXL12QMVJU 20 12.0 11.4 3.9 12,000 14,300 DH-16 MSLS1438144**-1/2 65 49
FVXS15NVJU RXL15QMVJU 20 12.5 11.3 4.0 15,100 18,300 DH-16 MSLS1412144**-1/2 98 65

More installation supplies & accessories, starting on page 59


If metal clad wire is required, order your line set and wire separately. Example: MSLS143850-1/2 + 58340803

23
AURORA ENHANCED CAPACITY FLOOR MOUNT
Specifications
Console Indoor Specifications
Model FVXS09LVJU FVXS12LLJU FVXS18LVJU
Cooling Capacity 4400 - 10,200 4400 - 12,300 5800 - 17,100
Heating Capacity 4400 - 14,300 4400 - 17,100 5800 - 24,000
Moisture Removal Quarts/Hour 0.325 0.45 0.63
Air Flow wet 290/230/169/145 300/237/173/159 378/325/275/233
Air Flow dry 311/244/177/155 332/258/184/166 417/357/300/251
Sound Pressure Cooling 38/32/26/23 39/33/27/24 44/40/36/32
Sound Pressure Heating 38/32/26/23 39/33/27/24 44/40/36/32
Dimensions 23 7/8 x 27 1/2 x 8 1/4
Weight 31 LB

Enhanced Capacity Outdoor Unit


Model RXL09NMVJU RXL12NMVJU RXL15NMVJU
Sound Pressure Cooling 49 50 50
Sound Pressure Heating 49 50 55
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling 14 - 115 Degrees F
Low Ambient*
Operating Range Cooling Low -4 - 115 Degrees F
Ambient with Wind Baffle
Operating Range Heating 5 - 75 Degrees F
Operating Range Heating -13 - 75 Degrees F
with Drain Pan Heater
Maximum Over Current 15A
Protection
Dimensions 21 5/8 x 26 1/2 x 11 1/8 28 15/16 x 34 1/4 x 12 5/8
Weight 60 lb 70 lb 108 lb

Accessories Control Options Wind Baffle For Low Ambient Cooling Applications
UL16x36 Condenser Pad BRP072A43 Wifi Interface KPW937E4 RXL09-15
BR440 Wall Bracket DACATS11 Daikin Wifi Control
X85003 Condensate Pump 09-18 BRC944B2A08 Convert to Wired Control
T18016 Pump Enclosure KRP067A41 Wire Control Adapter 09 & 12
KRP980B2 Wire Control Adapter 18 & 24
AG3000 Intermatic Surge Protector

Parts & Labor Plan Snow Protection Hood


EWDLVMXSO12PL Transferrable Extended Service Plan KPS067A41 RXL09 & RXL12 - Side
EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor KPS063A41 RXL15QMVJU - Side
KPS067A42 RXL09QMVJU & RXL12QMVJU - Back
Low Ambient Heating Options
KPS063A44 RXL15QMVJU - Back
KEH067A41E Drain Pan Heater RX 09-12
KPS067A44 RXL09QMVJU & RXL12QMVJU - Discharge
KEH063A4E Drain Pan Heater RX 18-24
KPS063A47 RXL15QMVJU - Discharge
24
VISTA 2X2 CEILING CASSETTE NEW
20 SEER MODEL
COMFORT Efficiency
2017
3D Airflow, Auto Swing Louvers Pam Control
Titanium Apatite Photo Catalytic Filter Inverter Technology
Hot Start & Auto Change Over
Outdoor Unit Quiet Operation DURABILITY
2, 3 or 4 Way Airflow Anti Corrosion Coating
Daikin Swing Compressor
Convenience
Self Diagnostic Control
Auto Restart Not Included
Page 57
Outside Air Knockouts
Pre Charged for Outdoor Unit & 33
Piping (Adj .22 oz/ft)
Low ambient
Timely
cooling to 0F
Vista Heat Pumps
registration are Available with optional
is required in in all regions Wind Baffle*
most states

Single Zone Ceiling Cassette Heat Pumps


Single Zone Ceiling Cassette Wall Mount Heat Pumps

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FFQ09Q2VJU RX09QMVJU BRC1E73 20.9 13 11.7 4.58 9,000 10,000 3/4 PVC MSWP1825 MSLS1438144**-1/2 65.6 49.2
FFQ12Q2VJU RX12QMVJU BRC1E73 20.2 12.5 11.2 4.02 10,800 13,500 3/4 PVC MSWP1825 MSLS1438144**-1/2 65.6 49.2
FFQ15Q2VJU RX15QMVJU BRC1E73 20.7 12.5 11.0 3.86 14,400 16,200 3/4 PVC MSWP1825 MSLS1412144**-1/2 98.4 65.6
FFQ18Q2VJU RX18QMVJU tba tba tba tba tba tba tba tba tba tba tba tba

More installation supplies & accessories, starting on page 59


If metal clad wire is required, order your line set and wire separately. Example: MSLS143850-1/2 + 58340803

25
VISTA 2X2 CASSETTE
Specifications
Vista 1:1 Ceiling Cassette Indoor Specifications
Model FFQ09 FFQ12 FFQ15
Cooling Capacity 4,600-11,000 4,600-13,300 5,100-16,200
Heating Capacity 4,600-14,000 4,600-16,800 5,200-16,300
Moisture Removal Quarts/Hour - - -
Air Flow wet 378-339-268 406-358-268 420-367-293
Air Flow dry 378-339-268 406-358-268 420-367-293
Sound Pressure Cooling 38/35/29 39-36-30 40-37-31
Sound Pressure Heating 38/35/29 39-36-30 40-37-31
Dimensions 22 5/8 x 22 5/8 x 10 1/4
Weight - - -
Vista Outdoor Specifications
Model RX09 RX12 RX15
Sound Pressure Cooling 46 49 50
Sound Pressure Heating 46 49 50
Operating Range Cooling 50-115
Operating Range Cooling Low - - -
Ambient*
Operating Range Cooling Low - - -
Ambient with Wind Baffle*
Operating Range Heating 5-64
Operating Range Heating with - - -
Drain Pan Heater**
Maximum Over Current
15A
Protection
Dimensions 21 5/8 X 26 9/16 X 11 3/16 28 15/16 X 34 1/4 X 12 5/8
Weight 60 lb. 97 lb.

Accessories Control Options Low Ambient Cooling Options


UL16x36 Condenser Pad BRC1E73 Control KPW063A4 Wind Baffle
BR440 Wall Bracket KRCS014B Remote Sensor Low Ambient Heating Options
KDDQ44XA60 Fresh Air Intake KEH063A4E Drain Pan Heater RX
BRYQ60A2W Sensor Kit (I/R)
I/R Controller (Sensor Kit
BRC7E830 Required)

Back & Side Wire Grille Parts & Labor Plan


KKG063A42 Back Wire Grille for 19 Series EWDLVMXSO12PL Transferrable Extended Service Plan
EWDLVMXSI12PL 6-12 Year Parts, 12 Year Labor

More installation supplies & accessories, starting on page 59

26
MULTI-SPLIT
MULTI-SPLIT SYSTEMS
SYSTEMS
Priority Room
(for systems only)

following cases:

make the outdoor unit run quietly.

is installed.

Priority with Inverter Powerful

27
MULTI-SPLIT SYSTEM FEATURES
COMFORT Durability INSTRUCTIONS
Priority Room Settings Anti-Corrosion Coating Always Size Line Set to Match
Quiet Operation Daikin Swing Compressor Indoor Unit
Automatic Changeover (heat/cool) Bushings are included
Powerful Mode Efficiency Indoor Models Pages 33-34
Hot Start (Heat Pump) Inverter Technology
Dry Mode Econo Mode
24 Hour On/Off Timer
Multi zone
systems are not
Timely
recommended for
registration Not all systems low ambient
is required in are Energy Star cooling
most states rated

System Indoor SEER EER HSPF COP Cooling Heating Min Indoor Max Indoor

Non Ducted 18.9 12.5 10.7 18,000


2MXS18NMVJU Ducted 14 9.5 8.2 4.1 16,000 25,000 2 2
Mixed 16.45 11 9.45 17,000
Non Ducted 17.0 12.7 10.3 18,000
2MXL18QMVJU
Ducted 14.0 10.1 8.2 4.2 18,000 17,390 @5 2 2
Enhanced Capacity
Mixed 15.5 11.4 9.25 18,000
Non Ducted 17.9 12.7 12.5 4.56 24,000
3MXS24NMVJU Ducted 14.0 9.7 8.2 3.88 23,400 36,000 2 3
Mixed 15.95 11.2 10.35 3.20 23,600
Non Ducted 17.9 12.7 12.5 24,000
3MXL24QMVJU
Ducted 14.0 9.9 8.2 4.56 24,000 23,000 @5 2 3
Enhanced Capacity
Mixed 15.95 11.3 10.35 24,000
Non Ducted 17.7 9.2 12.2 4.5 36,000
4MXS36NMVJU Ducted 14 7.9 8.2 3.44 36,000 38,000 2 4
Mixed 15.85 8.55 10.2 3.96 36,000
Non Ducted 18.8 10.3 11.3 3.0
RMXS48LVJU Ducted 16.5 9.8 10.5 2.9 48,000 54,000 2 8
Mixed 14.1 9.3 9.8 2.7

INDOOR MODELS: SEE PAGES 33-34 Low Ambient Heating Options


KEH041A43 Drain Pan Heater 3MXS & 4MXS G
UL16X36 CONDENSER PAD
KEH063A4E Drain Pan Heater for 2MXS, 3MXS & 4MXS N
DACAWB3 WALL BRACKET
KPS063A41 Snow Protection Hood Intake Side
Back & Side Wire Grille KPS063A44 Snow Protection Hood Intake Rear
KKG067A42 Back Wire Grille for 2/3/4MXS KPS063A47 Snow Protection Hood Outlet
KKG063A43 Side Wire Grille for 2/3/4MXS
12 Year Residential Parts Warranty, Registration Required
EWDLVMXSO12PL Transferrable Extended Service Plan
EWDLVMXSI12PL* 6-12 Year Parts, 12 Year Labor

28 *1 required for every indoor unit


utdoor Units Pre- Charged Connection Sizes
to 1 Unit Total Units Units
1/4 - 3/8
MXS18GVJU 98 82 164 2 2
1/4 - 3/8
1/4 - 3/8
Multi Zone
MXS24JVJU 131 Systems82 230 2 3 1/4 - 1/2
Specifications 1/4 - 5/8
Multi Zone Specifications 1/4 - 3/8
Model 2MXS18NMVJU 2MXL18QMVJU 3MXS24NMVJU 3MXL24QMVJU 4MXS36NMVJU RMXS48LVJU
1/4 - 1/2
Sound Pressure 131
MXS32GVJU 82 230 52 2 4 52
50 57
Cooling 1/4 - 5/8
Sound Pressure 51 54 54 1/4 - 5/8 58
Heating
Pre Charged 98 131 131 No
Operating Range Zone Heat Pumps
14 - 115 Degrees F
Cooling Cooling Condensate
Indoor Units Type Line Set (in.)
Btu/hare not recommended
Multi Zone Systems Btu/h for low Drain
ambient cooling applications
Operating Range
CTXS07JVJU Wall -4
Mounted
75 F -13 7,000
75 F -4 75 7,000
F -13 75 F11/16 -4 751/4
F - 3/8 -4 75 F
Heating
CTXS09HVJU
Maximum Over Wall Mounted 9,000 9,000 11/16 1/4 - 3/8
20 30
Current Protection
CTXS12HVJU Wall Mounted 12,000 12,000 11/16 1/4 - 3/8
Dimensions 29 X 34 1/4 X 12 5/8 52 15/16 X 35 7/16 X 12 5/8
Weight 128 lb 139 lb 132 lb 140 lb 137 lb 129 lb
FTXS15LVJU
Min Indoor Wall Mounted 2 15,000 15,000
2 11/16 2 1/4 - 1/2 2
Max Indoor 2 3 4 8
FTXS18LVJU Wall Mounted 18,000 18,000 11/16 1/4 - 1/2
Max Piping Height 49 49 49 See Installation Instructions
Max Piping Length 164' 230 440'
FDXS09LVJU
Max Length to 1 Unit Slim Duct 9,000 9,000 8211/16 1/4 - 3/8
FDXS12LVJU Slim Duct 12,000 12,000
Line Sets & Wiring 11/16 1/4 - 3/8
CDXS15LVJU
2 Zone Slim Duct 15,000 2} MSLS****144**-1/2
15,000 11/16 1/4 - 1/2
Refer to Bill of Materials
3 Zone
CDXS18LVJU Slim Duct 18,000 18,0003} MSLS****144**-1/2
11/16 1/4 - 1/2 page 32
4 Zone 4} MSLS****144**-1/2

See next page for approved system combinations (2/3/4 MXS) .


*Select indoor units from pages 33-34
** Line Set OD must be sized to match the indoor model selected. 25 & 50 lengths are available. Refer to indoor unit specifcations.

MSLS Line Sets

Copper Tubing

Power to Indoor

Communications

29
8
2/3/4 MXS MULTI-SPLIT SYSTEM MATCHES
Indoor Unit Combination (BTU) Indoor Unit Combination (BTU)
Outdoor Model Outdoor Model
2-Zone 2-Zone 3-Zone 4-Zone
7+7 7+7 7+7+7 7+7+7+7
7+9 7+9 7+7+9 7+7+7+9
9+9 7 + 12 7 + 7 + 12 7 + 7 + 7 + 12
7+7 7 + 15 7 + 7 + 15 7 + 7 + 7 + 15
7+9 7 + 18 7 + 7 + 18 7 + 7 + 7 + 18
2MXS18NMVJU 7 + 12 9+9 7+9+9 7+7+9+9
7 + 15 9 + 12 7 + 9 + 12 7 + 7 + 9 + 12
9+9 9 + 15 7 + 9 + 15 7 + 7 + 9 + 15
9 + 12 9 + 18 7 + 9 + 18 7 + 7 + 9 + 18
9 + 15 12 + 12 7 + 12 + 12 7 + 7 + 12 + 12
12 + 12 12 + 15 7 + 12 + 15 7 + 7 + 12 + 15
12 + 18 7 + 12 + 18 7 + 7 + 12 + 18
15 + 15 7 + 15 + 15 7+9+9+9
Indoor Unit Combination (BTU) 15 + 18 7 + 15 + 18 7 + 9 + 9 +12
Outdoor Model 18 + 18 7 + 18 + 18 7 + 9 + 9 + 15
2-Zone 3-Zone
7+7 7+7+7 18 + 24 9+9+9 7 + 9 + 9 + 18
7+9 7+7+9 24 + 24 9 + 9 + 12 7 + 9 + 12 + 12
7 + 12 7 + 7 + 12 9 + 9 + 15 7 + 9 + 12 + 15
7 +15 7 + 7 + 15 9 + 9 + 18 7 + 12 + 12 + 12
7 + 18 7 + 7 + 18 9 + 12 +12 9+9+9+9
9+9 7+9+9 9 + 12 + 15 9 + 9 + 9 + 12
4MXS36NMVJU
9 + 12 7 + 9 + 12 9 + 12 + 18 9 + 9 + 9 + 15
9 + 15 7 + 9 + 15 9 + 15 + 15 9 + 9 + 9 + 18
9 + 18 7 + 9 + 18 9 + 15 + 18 9 + 9 + 12 + 12
12 + 12 7 + 12 + 12 9 + 18 + 18 9 + 9 + 12 + 15
12 + 15 7 + 12 + 15 12 + 12 + 12 9 + 12 + 12 + 12
3MXS24NMVJU 12 + 18 7 + 12 + 18 12 + 12 + 15 7 + 7 + 7 + 24
15 + 15 7 + 15 + 15 12 + 12 + 18 7 + 7 + 7 + 24
15 + 18 9+9+9 12 + 15 + 15 7 + 7 + 7 + 24
18 + 18 9 + 9 + 12 12 + 15 + 18 7 + 7 + 7 + 24
9 + 9 + 15 7 + 7 + 24 7 + 7 + 7 + 24
9 + 9 + 18 7 + 9 + 24 7 + 7 + 9 + 24
9 + 12 + 12 7 + 12 + 24 7 + 7 + 15 +15
9 + 12 + 15 7 + 12 + 24 7 + 7 + 15 +18
9 + 12 + 18 9 + 9 + 24 7 + 7 + 18 + 18
9 + 15 + 15 9 + 12 + 24 7 + 9 + 12 + 18
12 + 12 + 12 9 + 15 + 24 7 + 9 + 15 + 15
12 + 12 + 15 12 + 12 + 24 7 + 12 + 12 + 15
12 + 18 + 18 9 + 9 + 12 + 18
15 + 15 + 15 9 + 9 + 15 + 15
Bold = Match is available for NMVJU & QMVJU 15 + 15 + 18 9 + 12 + 12 + 15
outdoor models only!
12 + 12 + 12 + 12

30
8-Zone Multi-Split Systems
Daikins 4 ton (48,000 Btu/h) 8-Zone Multi-Split heat pump system extends the
multi-split range and oers high eciency and greater exibility for larger spaces with the ability
to connect from 2 to 8 indoor units to a single outdoor unit. A variety of indoor units are available
to match the dcor of each room while oering individual room control for a multiple room or
whole house comfort solution.

Design Flexibility Space Saving Design


The 8-Zone Multi-Split System is a High Eciency solution Daikins 8-Zone Multi-Split System oers more than 60%
with optimum exibility. The system oers comfortable in physical space savings and more than 80% in total
zoning capabilities with the ability to connect up to 8 (including clearances) space savings compared to
indoor units with ease utilizing long pipe lengths, conventional outdoor unitsproviding a streamlined
standardized line-sets, simplied electrical requirements solution for limited spaces.
and staged installations.

Simplied Wiring Installation Ease


The outdoor unit and BP units operate from separate
Longer refrigerant piping capabilities oers much
208/230V single-phase power supplies. Indoor units are more exibility in the choice of installation positions
powered from the BP unit and wired as Daikins current for the indoor units, and greatly simplies system
4 wire single split systems reducing the wiring size and layout.
easing installation
31
RMXS48LVJU
Up to 8 Zone Multi
No. of Zones 2 3
Item Qty Part Number Qty Part Number
Outdoor Unit 1 RMXS48LVJU 1 RMXS48LVJU
Indoor Units 2 * 3 *
Control Wire to BP 1 MSWP1825 1 MSWP1825
1 00670500 1 00670500
Line Set from Outdoor Unit (Min 16')
1 01270820 1 01270820
Branch Port Boxes 1 BPMKS048A2U 1 BPMKS049A3U
Line Sets from BP to Indoor Units ** 2 MSLS****144**-1/2 3 MSLS****144**-1/2

No. of Zones 4 5 6
Item Qty Part Number Qty Part Number Qty Part Number
Outdoor Unit 1 RMXS48LVJU 1 RMXS48LVJU 1 RMXS48LVJU
Indoor Units 4 * 5 * 6 *
Control Wire to BP 1 MSWP1825 1 MSWP1825 1 MSWP1825
1 00670500 1 00670500 1 00670500
Line Set from Outdoor Unit (Min 16')
1 01270820 1 01270820 1 01270820
Refnet Fitting 1 KHRP26A22T 1 KHRP26A22T 1 KHRP26A22T
2 ** 2 ** 2 **
Line Set from Refnet
2 ** 2 ** 2 **
1 BPMKS048A2U
Branch Port Boxes 2 BPMKS048A2U 2 BPMKS049A3U
1 BPMKS049A3U
Line Sets from BP to Indoor Units ** 4 MSLS****144**-1/2 5 MSLS****144**-1/2 6 MSLS****144**-1/2

No. of Zones 7 8
Item Qty Part Number Qty Part Number
Outdoor Unit 1 RMXS48LVJU 1 RMXS48LVJU
Indoor Units 7 * 8 *
Control Wire to BP 1 MSWP1825 1 MSWP1825
1 0670500 1 0670500
Line Set from Outdoor Unit (Min 16')
1 01270820 1 01270820
Refnet Fitting 2 KHRP26A22T 2 KHRP26A22T
1 00670500 1 00670500
Line Set Refnet to Refnet
1 01070500 1 01070500
3 ** 3 **
Line Set from Refnets
3 ** 3 **
2 BPMKS048A2U 1 BPMKS048A2U
Branch Port Boxes
1 BPMKS049A3U 2 BPMKS049A3U
Line Sets from BP to Indoor Units ** 7 MSLS****144**-1/2 8 MSLS****144**-1/2
* Connection Ratio (for System & BP Boxes): 50 - 130%. Select indoor units from Multi Zone Indoor Units on pages 33-34
Line Set OD must be sized to match the indoor model selected. 25 & 50 lengths are available. Refer to indoor unit specifications.
Indoor units are powered from the Branch Port Boxes.
Outdoor Unit & Branch Port Boxes are powered individually.
Use MSWP1825 Control Wire to connect Outdoor Unit & Branch Port Boxes.
** Determine refrigerant charge and refnet line sets by using the multi split selection tool (software)

32
CTXS/FTXS Wall Mount
Optional Wifi Control
See Page 53

Wall Mount Indoor unit specifications (Multi Zone)


Model CTXS07LVJU CTXS09HVJU FTXS09LVJU CTXS12HVJU FTXS12LVJU FTXS15LVJU FTXS18LVJU FTXS24LVJU
2MXS 2MXS 2MXS* 2MXS* 2MXS*
3MXS 3MXS 3MXS* 3MXS 3MXS* 3MXS* 3MXS*
Compatibility
4MXS 4MXS 4MXS* 4MXS 4MXS* 4MXS* 4MXS* 4MXS*
RMXS RMXS RMXS RMXS RMXS RMXS RMXS RMXS
Drain DH-16
Condensate Pump X85003 X87721
Line Set MSLS1438144**-1/2 MSLS1412144**-1/2 MSLS1458144**-1/2
Air Flow wet 332/261/194/145 381/279/194/145 403/307/205/155 568/477/385/360 583/484/385/360 643/494/350/328
Air Flow dry 350/290/233/219 420/321/233/219 438/335/240/212 593/505/417/371 625/526/431/399 699/572/445/403
Sound Pressure Cooling 38/32/25/22 41/33/25/22 45/37/29/23 45/40/35/32 46/41/36/33 51/42/37/34
Sound Pressure Heating 38/33/28/25 42/35/28/25 45/39/29/26 43/38/33/30 45/40/35/32 48/42/37/34
Dimensions 11 5/8 x 31 1/2 x 8 7/16 13 3/8 x 41 5/16 x 9 3/4
Weight 20 lb 22 lb 31 lb
*Not compatible with GVJU + JVJU models

CTXG Optional Wifi Control


See Page 53

Model CTXG09QVJU(W/S) CTXG12QVJU(W/S) CTXG18QVJU(W/S)


2MXS 2MXS
3MXS 3MXS 3MXS
Compatibility
4MXS 4MXS 4MXS
RMXS RMXS RMXS
Drain DH-16
Condensate Pump X85003
Line Set MSLS1438144**-1/2 MSLS1412144**-1/2
Air Flow wet tba
Air Flow dry tba
Sound Pressure Cooling 38/25 45/26 46/35
Sound Pressure Heating 41/28 45/29 47/35
Dimensions 11 9/10 x 39 3/10 x 8 3/10
Weight 26 lb
Emura is available in white and silver

33
FDXS/CDXS DC Ducted Optional Wifi Control
See Page 53

Ducted Indoor unit specifications (Multi Zone)


Model FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU
Max ESP 0.12' wc 0.16' wc
2MXS 2MXS* 2MXS*
3MXS 3MXS 3MXS 3MXS
Compatibility
4MXS 4MXS 4MXS 4MXS 4MXS*
RMXS RMXS RMXS RMXS RMXS
Drain 3/4 PVC
Condensate Pump X85003 X87721
Line Set MSLS1438144**-1/2 MSLS1412144**-1/2 MSLS1458144**-1/2
Air Flow wet 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 565/523/477/395
Air Flow dry 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 565/523/477/395
Sound Pressure Cooling 35/33/31 35/33/31 37/35/33/31 37/35/33/31 38/36/34/32
Sound Pressure Heating 35/33/31 35/33/31 37/35/33/31 37/35/33/31 38/36/34/32
Dimensions 7 7/8 x 27 9/16 x 24 7/16 7 7/8 x 35 7/16 x 24 7/16 7 7/8 x 43 5/16 x 24 7/16
Weight 20 lb 22 lb 27 lb 66 lb
*Not compatible with GVJU + JVJU models

FFQ Ceiling Cassette BRC1E73


Not Included
Page 57

FFQ Series Ceriling Cassette Multi Zone Indoor Specifications


Model FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU
Control BRC1E73
Control Wire MSWP1825
2MXS 2MXS* 2MXS*
3MXS 3MXS 3MXS 3MXS
Compatibility
4MXS 4MXS 4MXS 4MXS
RMXS RMXS RMXS RMXS
Drain 3/4" PVC
Line Set MSLS1438144**-1/2 MSLS1412144**-1/2
Air Flow dry 318/230 353/230 424/283 530/353
Sound Pressure Cooling 36/29 38/29 42/31 46/37
Sound Pressure Heating 36/29 38/29 42/31 46/37
Dimensions 11 1/4 X 22 5/8 X 22 5/8
Dimensions (Panel) 2 1/4 x 27 5/8 x 27 5/8
Weight 38.5 LB
*Not compatible with GVJU + JVJU models

FVXS Floor Mounted Optional Wifi Control


See Page 53

FVXS Series Console Multi Zone Indoor Specifications


Model FVXS09LVJU FVXS12LVJU FVXS18LVJU
2MXS* 2MXS*
3MXS* 3MXS* 3MXS*
Compatibility
4MXS* 4MXS* 4MXS*
RMXS RMXS RMXS
Drain 3/4" PVC
Line Set MSLS1438144**-1/2 MSLS1438144**-1/2 MSLS1412144**-1/2
Air Flow wet 290 300 378
Air Flow dry 311 332 417
Sound Pressure Cooling 38/32/26/23 39/33/27/24 44/40/36/32
Sound Pressure Heating 38/32/26/23 39/33/27/24 44/40/36/32
Dimensions 23 7/8 x 27 1/2 x 8 1/4
Weight 31 LB
*Not compatible with GVJU + JVJU models 34
NEW

VRV IV S-series


ENERGY-INTELLIGENT TECHNOLOGY
HEATING AND COOLING SYSTEMS

Next Generation Mini VRV


The Daikin VRV IV-S series completes the VRV air cooled
offering by introducing Variable Refrigerant Temperature
(VRT) technology in smaller size and capacities, providing
year round comfort and energy savings in a smaller footprint.
With the ability to connect up to 10** indoor units to one
outdoor unit and long piping lengths (up to 984** ft. total
piping length), the space saving VRV IV-S series system is
ideal for most light commercial and residential applications.

Features and Benefits


Available in 3, 4 and 5 ton modules 5 Ton
Improved year round comfort and energy Module
savings as compared to VRVIII-S thanks to
the newly added VRT technology
Broader diversity with ability to connect repla cement
3 and 4 Ton co mpresso r
up to 10 indoor units
Modules
Space saving design with under 39** height.
Over 25% smaller as compared to VRV III-S
Easier to install with over 60% weight
reduction vs VRV III-S
Light Commercial and Residential
Low sound levels for comfort
Uses Daikins reliable swing compressors A highly efficient solution, the VRV IV-S series provides
Dependable operation in extreme cooling and heating for up to 10 zones. With many
ambient conditions up to 122F different indoor unit options to choose from, systems
Safety and peace of mind with optional can be paired with a mix of ducted and duct-free indoor
auto changeover to auxiliary heat units for a customizable system. Designed for flexibility
Backed by a 10-Year Parts Limited Warranty and versatility, the VRV IV-S series system provides long
and 10-Year Replacement Compressor Limited Warranty piping lengths, making it an accommodating and space-
Piping, refrigerant charge and indoor unit selection will be saving solution for almost any floor layout.
layed out with assistance from a United Refrigeration sales
engineer

**Refer to the engineering manual for details

35
VRT mode control selection to match user preferences
VRT mode is efficiency focused while Basic mode is capacity focused.

Capacity priority Energy saving priority

Fixed Refrigerant Temperature Variable Refrigerant Temperature

Ambient VRV IV-S BASIC MODE AUTO MODE HIGH SENSIBLE MODE
Fixed Te - Standard control Floating target Te depending on heat load Fixed target Te
122F
Selecting VRT enables operation to be optimised for either energy efficiency or rapid cooling.

Floating Te Fixed Te
C o oling

77F

POWERFUL MODE QUICK MODE MILD MODE ECO MODE

Unable to change Te
Heating

Reaction speed Very Fast Reaction speed Fast Reaction speed Medium

23F Can boost capacity above 100% Gives priority to fast reaction speed. Gives priority to efficiency.
if needed. The refrigerant temperature goes The refrigerant temperature goes
The refrigerant temperature can go down fast to keep the room down gradually giving priority to the
lower in cooling than the set minimum. setpoint stable. efficiency of the system instead of the
-4F Gives priority to very fast reaction speed.
reaction speed.
-13F The refrigerant temperature goes down
fast to keep the room setpoint stable.

The Daikin Swing Compressor


Daikin VRV IV-S series is built with the highly reliable Daikin swing compressor
Daikins swing compressor technology integrates all the moving parts into one component
The integration minimizes abrasion between moving parts and refrigerant leakage through gaps from
high to low pressure zones
Daikins swing compressors deliver higher compressor efficiencies than a standard rotary compressor

SERIES 3 TON 4 TON 5 TON


Model Name
Nominal Cooling Capacity BTU/h 34,000 45,500 57,000
Nominal Heating Capacity BTU/h 38,000 49,500 57,000
Operation Range Cooling F DB 23 to 122
PERFORMANCE
Operation Range Heating F WB -4 to 60
Power V/p/Hz 208-230/1/60
Sound Pressure Level @ 3ft dBA 58 58 57
Refrigerant R410A
Refrigerant Quantity lbs 6.4 7.5 7.9
Liquid Pipe (Main Line) in 3/8 3/8 3/8
Suction Gas Pipe (Main Line) in 5/8 5/8 3/4
REFRIGERANT PIPING
Vertical Pipe Length ft 98
Maximum vertical pipe length between IDU ft 33 49 49
Actual Pipe Length (Equivalent Length) ft 164 230 230
Total Piping Length ft 820 984 984
Connectable Indoor Unit Ratio % 50-130
CONNECTION RATIO
Number of Indoor Units Qty 6 8 10
Outdoor Unit Size (HxWxD) 39 x 37 x 12-5/8 39 x 37 x 12-5/8 52-15/16 x 35-7/16 x 12-5/8
UNIT
Weight lbs. 172 176 225
Airflow CFM 2682 2682 3741
FAN
Fan Motor Output and Quantity kW 0.20 x 1 0.20 x 1 0.070 X 2
Maximum Over Current Protection (MOP) A 25 35 35
ELECTRICAL Minimum Circuit Amps (MCA) A 16.5 29.1 29.1
Rated Load Amps (RLA A 15.3 19.0 23.2
Compressor Type Type Daikin Swing Daikin Swing Daikin Swing
COMPRESSOR
Capacity Control % 20-100 14-100 14-100
Single Fan Single Fan Double Fan

ODU Style Fan Type

Daikin VRV outdoor units can only be installed with Daikin VRV indoor units. Unit selection must be done by a United Refrigeration sales engineer.

36
3 PHASE
SETTING THE STANDARD AGAIN

VRV IV Air-Cooled Heat Pump


Daikins VRV IV systems integrate advanced technology to
provide comfort control with maximum energy efficiency and
relabilty. Currently available in heat pump configurations,
VRV IV provides a solution for multi-family residential to large
commercial applications desiring heating or cooling. The VRV
IV is the first variable refrigerant flow (VRF) system to be be
assembled in North America.
Features:
Total comfort solution for heating, cooling, ventilation and controls
Redesigned and optimized for total Life Cycle Cost (LCC)
Reduced install cost and increased flexibility as compared to
VRV III with larger capacity single modules up to 14 Tons and
system capacity up to 34 Tons
Efficiency improved over VRV III by an average of 11% with IEER
Values now up to 28
Improved seasonal efficiency as compared to VRV III with
automatic and customizable Variable Refrigerant Temperature (VRT)
climate tuning
Best-In-class warranty* with 10 year compressor and parts limited
warranty as standard
Reduced commissioning time vs. VRV III with VRV configurator
software and Graphical User Interface (GUI) Additional information
Before purchasing this appliance, read important information
Design flexibility with long piping lengths up to 3,280 ft. total
about its estimated annual energy consumption, yearly
and 100 ft. vertical separation between indoor units operating cost, or energy efficiency rating that is available
Take advantage of Daikins unique zone and centralized controls from United Refrigeration.

FIND OUT MORE ABOUT DAIKIN VRV.

COMMERCIAL RENOVATION NEW CONSTRUCTION

37
3 PHASE
ENERGY-INTELLIGENT HEATING AND COOLING SYSTEMS

VRV IV Air-Cooled Heat Recovery


Daikins VRV IV systems integrate advanced technology to
provide comfort control with maximum energy efficiency and
reliability. VRV IV provides a heating and cooling solution
for multi-family residential to large commercial applications.
Daikin VRV IV is the first variable refrigerant flow (VRF) system
to be assembled in North America.

Main Features and Benefits:


Total comfort solution for heating, cooling, ventilation and controls
All inverter compressors and inverter fan motors optimize
part load efficiency.
Redesigned and optimized for low total Life Cycle Cost (LCC)
New single/multiple port branch selector boxes provide
compact dimensions and a wide range of product offerings
(single, 4, 6, 8, 10 and 12 port options)
Reduced install cost and increased flexibility as compared to
VRV III with larger capacity single modules up to 14 Tons and
system capacity up to 38 Tons
Additional information
Efficiency improved over VRV III by an average of 21% with
Before purchasing this appliance, read important information
IEER Values now up to 29.3
about its estimated annual energy consumption, yearly
Improved seasonal efficiency as compared to VRV III with operating cost, or energy efficiency rating that is available
automatic and customizable Variable Refrigerant Temperature (VRT) from United Refrigeration.
climate tuning
Best-In-class warranty* with 10 year compressor and parts limited
warranty as standard
Reduced commissioning time vs. VRV III with VRV configurator
software and Graphical User Interface (GUI)
Design flexibility with long piping lengths up to 3,280 ft. total
and up to 100 ft. vertical separation between indoor units
Take advantage of Daikins unique zone and centralized controls that
are optimized for the specific needs of North America

COMMERCIAL RENOVATION NEW CONSTRUCTION

38
SkyAirSystems
SkyAir Systems
SkyAiristheultimateductedandductfreesolutionforlightcommercialandresidentialwholehouse
applications.Rangingfrom18,000Btu/hto42,000Btu/h,theseinnovativesystemsprovideenergy
efficiency,technologicalreliabilityandinstallationflexibility.

Keyfeaturesandbenefitsinclude:
DC fanmotorimprovesefficiencycomparedtoconventionalAC
motors.
Aerospiralfanandgrilleminimizesturbulenceandincreases
soundreduction.
Reluctancebrushless DCcompressorincreasesefficiency.
Swingcompressorwithfrictionreductionandquieterrotationor
scrollcompressorwithrobustandlow sounddesignprovides
maximumdurability.
Longpipinglengthsupto230ft.allowlayoutflexibility.
Anticorrosiontreatmentontheoutdoorheatexchanger
increasesdurability.

Theseonetoonesystemsofferconnectivitywithavarietyofindoorunitsforasimplesolutionfor
almostanyapplication.
Wallmountedunitsarecompactandmadewithasophisticateddesigntoblendin
discretelywithanyinteriordcor.Theseunitsfeaturewideanglelouversandauto
swingfunctionsforcomfortableairflowdistribution.

DCDuctedunitsofferalowprofiledesignforaneasilyconcealedlook.Atlessthan
12inheight,thesebuiltinsystemsprovideapowerfulsolutionforanysmalltomid
sizeapplication.

Roundflowceilingcassettesprovideanelegantandcustomizablesolutionidealfor
openplanapplications.Easilycleanedwithairflowflexibility,systemsarealow
maintenanceoptionforallaroundcomfort.

Ceilingsuspendedunitshaveaslimandelegantdesignforopenorstructured
applications.Withwideairopeningsandaninnovativestreamfan,operationisquiet
andcomfortablethroughouttheentirespace.

Daikinsinverterductedunitsareacosteffective,spacesavingalternativeto
traditionalsystems.Thesesystemsaredesignedforquietoperationwithsuperior
heatingcapabilities.

20

39
SkyAir Features
SkyAir

Type Cool Only and Heat Pump

FTXS

FHQ
FBQ

FCQ
FAQ

FTQ
Models

Regional Standards Compliance A/C * NS NS NS NS NS NS

Regional Standards Compliance Heat Pump ALL ALL ALL ALL ALL ALL

Warranty 10 10 10 10 10 10

Pulse Amplitude Modulation


Power Airflow Dual Flaps
Comfortable Airflow

Wide Angle Louvers


Vertical Auto Swing (up and down)
Horizontal Auto Swing (left and right)
3 D Airflow
Comfortable Mode
Indoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Comfort Control

Intelligent Eye
Automatic Operation (heat pump only)
Program Dry Function
Auto Fan Speed
Hot Start (heat pump only)
Mold Proof Air Filter
Healthy

Titanium Apatite Photocatalytic Air Purifying Function


Wipe Clean Flat Panel
Standby Electricity Saving
Econo Mode

Lifestyle

Powerful Operation
Remote Controller with backlit display
LCD Wireless Remote Control
Indoor Unit On/Off Timer
24 Hour On/Off Timer
Timers

Weekly Timer
Night Set Mode
Auto Restart after Power Failure
Worry Free

Self Diagnosis with Digital Display


Anticorrosion Treatment of Outdoor Heat Exchanger Fin
Standard Feature Optional Feature With BRC1E73 Controller
* Some sizes may be compliant in the Southwest. Refer to individual specs for details.

40
FAQ WALL MOUNTED
Sky Air Control
Not Included
Page 57
Comfort Convenience Efficiency
Vertical Auto Swing Louvers Self Diagnostic PAM Control
Outdoor Unit Quiet Operation Auto Restart Indoor Unit Timer
Hot Start & Auto Changeover
(Heat Pump) Pre Charged for Outdoor Durability
Dry Mode Unit Only Adjust Charge Anti-Corrosion Coating Low ambient
Mold Proof Air Filter .55 oz/ft Daikin Swing Compressor cooling to 0F
with optional
Wind Baffle

Timely
registration FAQ 24 A/C FAQ Heat
is required in Model is not Pumps are
most states available in the available in
Southwest all regions

Single Zone Wall Mount Cooling only

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FAQ18PVJU RZR18PVJU BRC1E73 18.6 12.7 ----- ----- 18,000 ----- DH-16 MSWP1825 MSLS3858**-1/2 164 98
FAQ24PVJU RZR24PVJU BRC1E73 17.6 10.2 ----- ----- 24,000 ------ DH-16 MSWP1825 MSLS3858**-1/2 164 98

Single Zone Wall Mount Heat Pump


FAQ18PVJU RZQ18PVJU9 BRC1E73 18.6 12.7 8.7 3.04 18,000 20,000 DH-16 MSWP1825 MSLS3858**-1/2 164 98
FAQ24PVJU RZQ24PVJU9 BRC1E73 17.6 10.2 9.1 2.15 24,000 26,000 DH-16 MSWP1825 MSLS3858**-1/2 164 98

41
FAQ WALL MOUNTED
Specifications
FAQ Series Wall Mount Indoor Specifications
Model FAQ18PVJU FAQ24PVJU
Cooling Capacity 18,000 24,000
Heating Capacity 20,000 26,000
Air Flow 400/500 470/635
Sound Pressure 37/43 37/43
Maximum Over Current Protection 15
Dimensions 11 3/8 x 41 3/8 x 9
Weight 31 lb

RZ* Series Outdoor Specifications


Model RZ*18PVJU RZ*24PVJU
Sound Pressure 49/49
Operating Range Cooling Low 23 - 115
Ambient*
Operating Range Cooling Low 0 - 115
Ambient with Wind Baffle
Operating Range Heating (Q 0 - 77
only)
Maximum Over Current Protection 20
Dimensions 30 5/16 x 35 7/16 x 12 5/8
Weight 150 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad (Control is not included with the system) For Low Ambient Cooling Applications
DACAWB3 Wall Bracket BRC1E73 NavigationRemoter Controller KPW5E80 All RZR & RZQ
X87721 Condensate Pump BRC2A71 Simplified Control (36 & 42 models have 2 fans & require 2 wind baffles)
T18016 Pump Enclosure KRCSO11B Remote Sensor
KRCSPW40 RS Cable 40
KRCSPW80 RS Cable 80
BRC7E818 Wireless Remote Control (FAQ)
AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59

42
LV SERIES WALL MOUNTED
30-36 Optional Wifi
See pg 53
COMFORT CONVENIENCE Efficiency
Wide Angle Louvers Remote Control with Inverter Technology
Comfortable Mode Backlit Display Included PAM Control
Powerful Mode Night Set-Back Function Econo Mode
Automatic Fan Speed Indoor Unit On/Off Switch 24 Hour On/Off Timer Low ambient
Dry Mode Wipe Clean Indoor Unit Intelligent Eye
Mold Proof Air Filter Self Diagnostic Control Stand-by Electric Savings cooling to 0F
Titanium Apatite Air Auto Restart Weekly Timer with optional
Purifier Wind Baffle*
Quiet Operation Indoor & Pre-Charged Condensing Durability
Outdoor Units (33) Adjust Charge Anti-Corrosion Coating
Hot Start & Auto .55 oz/ft Daikin Swing Compressor
Changeover
3D Airflow
Power Dual Flaps RKS 30 + 36
Cooling to -40 with
optional control

Timely
LV Series 30-36 LV Series
registration
A/C Models are Heat Pumps
is required in
not available in are available
most states
the Southwest in all regions

Sky Air Wall Mount Cooling Only

Cooling Heating Line Set Max. Max.


Indoor Outdoor SEER EER HSPF COP Drain
Btu/h Btu/h w/ Wire Length Height

FTXS30LVJU RKS30LVJU 19.3 10.70 ----- ----- 30,000 ----- DH-16 MSLS3858144**-1/2 98 66
FTXS36LVJU RKS36LVJU 17.9 8.35 ----- ----- 36,000 ----- DH-16 MSLS3858144**-1/2 98 66

Sky Air Wall Mount Heat Pumps


FTXS30LVJU RXS30LVJU 19.3 10.70 8.3 ----- 30,000 34,800 DH-16 MSLS3858144**-1/2 98 66
FTXS36LVJU RXS36LVJU 17.9 8.35 8.3 ----- 36,000 38,000 DH-16 MSLS3858144**-1/2 98 66

*Low ambient cooling instructions:


Turn On DIP switch B in SW4 on outdoor unit main PCB
If metal clad wire is required, order your line set and wire separately. Example: MSLS385850-1/2 + 58340803

43
LV SERIES WALL MOUNT
Specifications
LV Series Wall Mount Indoor Specifications
Model FTXS30LVJU FTXS36LVJU
Cooling Capacity 10,200 - 30,000 10,200 - 36,000
Heating Capacity 10,200 - 34,000 10,200 - 38,000
Moisture Removal Gallons/Hour
Air Flow wet
473 / 519 / 706 474 / 519 / 770
Air Flow dry
Sound Pressure Cooling
40/47 40/47
Sound Pressure Heating
Dimensions 13 3/8 x 47 1/4 x 9 7/16
Weight 38 lb

LV Series Outdoor Specifications


Model R*S30LVJU R*S36LVJU
Sound Pressure Cooling
54 54
Sound Pressure Heating
Operating Range Cooling 50 - 115 Degrees F
Operating Range Cooling Low 14 - 115 Degrees F
Ambient*
Operating Range Cooling Low 0 - 115 Degrees F
Ambient with Wind Baffle
Operating Range Cooling With Wind -40 to 115 F
Baffle & Ultra Low Ambient Control
Operating Range Heating 5 - 77 Degrees F
Maximum Over Current Protection 20A
Dimensions 38 15/16 x 37 x 12 5/8
Weight 179 lb

Accessories Control Options Low Ambient Cooling Options


UL16x36 Condenser Pad BRC944B2A08 Convert to Wired Control KPW5E112 Wind Baffle RKS/RXS 30-36
DACAWB3 Wall Bracket DACATS11 Daikin Envi Wifi Control 2F018535-1 -40 Low Ambient Control RKS 30*
X87721 Condensate Pump BRP072A43 Wifi Interface 2F018535-2 -40 Low Ambient Control RKS 36*
T18016 Pump Enclosure KRP928BB2S DIII Net Interface * Wind Baffle Required
AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59

44
FBQ Inverter Ducted
Sky Air Control
Not Included
FBQ_PVJU
Page 57
Comfort Convenience Efficiency
Dry Mode Self Diagnostic Control Inverter Technology
Mold Proof Air Filter Auto Restart PAM Control
Quiet operation Outdoor Unit 12 Height 24 Hour On/Off Timer
Hot Start & Auto changeover Built in Condensate Pump Low ambient
(Heat Pump) Bottom Access Durability cooling to 0F
Up to .8 Static with optional
Pre Charged for Outdoor Anti-Corrosion Coating
Unit only Adjust Charge Daikin Swing Wind Baffle
.55 oz/ft Compressor (18 - 30)
Daikin Scroll
Compressor (36 & 42)

Timely
FBQ24-42 A/C FBQ Series
registration
models are not Heat Pumps
is required in
available in the are available
most states
Southwest in all regions

Single Zone Horizontal Ducted Air Conditioning

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FBQ18PVJU** RZR18PVJU BRC1E73 17.5 14.1 18,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ24PVJU** RZR24PVJU BRC1E73 16.5 12.0 24,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ30PVJU** RZR30PVJU BRC1E73 16 10.5 30,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ36PVJU** RZR36PVJU BRC1E73 17.5 11.2 36,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164'
FBQ42PVJU** RZR42PVJU BRC1E73 16 10.2 42,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164'

Single Zone Horizontal Ducted Heat Pump


FBQ18PVJU** RZQ18PVJU9 BRC1E73 17.5 14.1 10.6 3.8 18,000 20,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ24PVJU** RZQ24PVJU9 BRC1E73 16.5 12.0 10.5 3.4 24,000 27,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ30PVJU** RZQ30PVJU BRC1E73 16 10.5 9.2 3.3 30,000 34,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FBQ36PVJU** RZQ36PVJU9 BRC1E73 17.5 11.2 9.1 3.5 36,000 40,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164'
FBQ42PVJU** RZQ42PVJU9 BRC1E73 16 10.2 8.8 3.4 42,000 47,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164'
**FBQ18 1/4 - 1/2 connections. Reduce at the indoor unit

Optional Zoning Box


See Page 46

45
FBQ Inverter Ducted
Specifications
FBQ Series Ducted Indoor Specifications
Model FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU
Max ESP Up to .80
Cooling Capacity 18,000 24,000 30,000 36,000 42,000
Heating Capacity 20,000 27,000 34,000 40,000 47,000
Air Flow 529/582/635 565/618/688 706/794/882 812/953/1130 988/1165/1377
Sound Pressure 37/39/41 38/40/42 39/41/43 39/41/43 40/42/44
Maximum Over Current Protection 15 15 15 15 15
Dimensions 11 13/16 x 38 3/8 x 27 9/16 11 13/16 x 55 1/8 x 27 9/16
Weight 80 lb 102 lb

RZ* Series Outdoor Specifications


Model RZ*18PVJU RZ*24PVJU RZ*30PVJU RZ*36PVJU RZ*42PVJU
Sound Pressure 49/49 58/58
Operating Range Cooling Low Ambient 23 - 115
Operating Range Cooling Low 0 - 115
Ambient with Wind Baffle
Operating Range Heating (RZQ only) 0 - 77
Maximum Over Current Protection 20 20 20 30 30
Dimensions 30 5/16 x 35 7/16 x 12 5/8 52 15/16 x 35 7/16 x 12 5/8
Weight 150 lb 283 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad (Control is not included with the system) For Low Ambient Cooling Applications
DACAWB3 Wall Bracket BRC1E73 NavigationRemoter Controller KPW5E80 All RZR & RZQ
AGG30X50 Aux Drain Pan BRC2A71 Simplified Control (36 & 42 models have 2 fans & require 2 wind baffles)
AGG30X60 Aux Drain Pan BRC4C82 Wireless Remote Control (FBQ)
AG1201+ Aux Drain Pan Switch KRCSO11B Remote Sensor
KRCSPW40 RS Cable 40
KRCSPW80 RS Cable 80
AG3000 Intermatic Surge Protector

Components sold separately The Main Thermostat is a wired color touch display
A Zoning Box (mounted on the Indoor Unit discharge master unit used to configure the DZK system. It can also
side), a Main Zone Thermostat and wireless Zone be used as a thermostat for one of the zones.
Thermostats. The Zone Thermostat is a battery powered touch
The Zoning Box is a plenum with motorized zone display unit that is used for one zone. Each Zone
dampers that constantly modulate the conditioned Thermostat monitors and allows the user to select a
air flow into each zone through standard ductwork, comfortable room temperature, and program or adjust
in response to the demand from the individual Zone the control functions (scheduling,ventilation, etc.) for the
Thermostat. room.
For FBQ ducted indoor units

Part # Description Compatable with


DZK030E4 4 Zones FBQ18, 24 & 30
DZK030E5 5 Zones FBQ18, 24 & 30
DZK048E4 4 Zones FBQ36 & 42
DZK048E6 6 Zones FBQ36 & 42
DZKMTS1W Main Thermostat (required)
DZK2TS1W Thermostat for additional zones (optional)

More installation supplies & accessories, starting on page 59 46


FTQ Inverter Ducted Control
Sky Air Not Included
Page 57

Comfort Convenience Efficiency FTQ_PBVJU


Dry Mode Self Diagnostic Control Inverter Technology
Mold Proof Air Filter Auto Restart PAM Control
Quiet operation Outdoor Unit Up Flow / Horizontal Right 24 Hour On/Off Timer
Hot Start & Auto changeover
Pre Charged for Outdoor Durability
Unit only Adjust Charge Anti-Corrosion Coating
.55 oz/ft Daikin Swing Compressor (18 - 30)
Daikin Scroll Compressor (36 & 42)

Timely Low ambient


FTQ Series
registration cooling to 0F
Heat Pumps
is required in with optional
are available
most states Wind Baffle
in all regions

Single Zone Up Flow Ducted Heat Pump

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FTQ18PBVJU RZQ18PVJU9 BRC1E73 20 14.5 12 4 18,000 20,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FTQ24PBVJU RZQ24PVJU9 BRC1E73 19 13.5 11.5 3.8 24,000 27,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FTQ30PBVJU RZQ30PVJU9 BRC1E73 19.5 13.5 10 3.7 30,000 34,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164' 98'
FTQ36PBVJU RZQ36PVJU9 BRC1E73 18 12.5 9.5 3.6 36,000 40,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164
FTQ42PBVJU RZQ42PVJU9 BRC1E73 17 12.0 9.5 3.2 40,000 47,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230' 164

Electric Heater Capacity


Model Name HKR-03 HKR-05C HKR-06 HKR-08C HKR-10C HKR-15C
FTQ18PBVJU l l X X X
FTQ24PBVJU l l l l X
FTQ30PBVJU l l l X
FTQ36PBVJU l l l X
FTQ42PBVJU l l*
EHK may be used for auxilliary heat l EHK is for emergency heat only X Not allowed.
*Acceptable for 2-step control
KER26A60 electric heat connection kit is required

47
FTQ Inverter Ducted
Specifications
FTQ Series Ducted Indoor Specifications
Model FTQ18PVJU FTQ24PVJU FTQ30PVJU FTQ36PVJU FTQ42PVJU
Max ESP Up to .50"
Cooling Capacity 9 - 18,000 9 - 24,000 12 - 30,000 12 - 36,000 12 - 42,000
Heating Capacity 9 - 20,000 9 - 27,000 12 - 34,000 12 - 40,000 12 - 47,000
Air Flow 420/510/600 560/680/800 700/850/1,000 840/1,020/1,200 980/1,190/1,400
Maximum Over Current Protection See instructions
Dimensions 22 x 26 x 48 1/8 22 x 26 x 58 1/4
Weight 150 lb 190 lb 203 lb

RZQ Series Outdoor Specifications


Model RZ*18PVJU RZ*24PVJU RZ*30PVJU RZ*36PVJU RZ*42PVJU
Sound Pressure 49/49 58/58
Operating Range Cooling Low 23 - 115
Ambient*
Operating Range Cooling Low 0 - 115
Ambient with Wind Baffle
Operating Range Heating (RZQ 0 - 77
only)
Maximum Over Current 20 20 20 30 30
Protection
Dimensions 30 5/16 x 35 7/16 x 12 5/8 52 15/16 x 35 7/16 x 12 5/8
Weight 150 lb 283 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad (Control is not included with the system) For Low Ambient Cooling Applications
DACAWB3 Wall Bracket BRC1E73 NavigationRemoter Controller KPW5E80 All RZR & RZQ
X87721 Condensate Pump KRCS01-4B Remote Sensor (36 & 42 models have 2 fans & require 2 wind baffles)
AGG30X50 Aux Drain Pan KER26A60 Electronic Heat Connection Kit
AGG30X60 Aux Drain Pan KRCSO11B Remote Sensor
AG1201+ Aux Drain Pan Switch KRCSPW40 RS Cable 40
KRCSPW80 RS Cable 80
AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59

48
FCQ ROUND FLOW CASSETTE Control
Sky Air Not Included
Page 57

Comfort Convenience Efficiency


Vertical Auto Swing Louvers Self Diagnostic PAM Control
Outdoor Unit Quiet Auto Restart Inverter Technology
Operation Outside Air Knockouts
Hot Start & Auto Built in Condensate Pump Durability
Changeover (Heat Pump) Anti-Corrosion Coating Low ambient
Dry Mode Pre Charged for Outdoor Daikin Swing Compressor (18-30) cooling to 0F
Mold Proof Air Filter Unit Only Daikin Scroll Compressor (36, 42) with optional
Add .55 oz/ft for Wind Baffle
additional piping

Timely Some FCQ FCQ Series


registration A/C Models Heat Pumps
is required in are not are available
most states available in in all regions
the Southwest

Sky Air Round Flow Ceiling Cassette Cooling Only

AC Only Cooling Heating Control Max. Max.


Indoor Control SEER EER HSPF COP Drain Line Set
Outdoor Btu/h Btu/h Wire Length Height

FCQ18PAVJU** RZR18PVJU BRC1E73 18.6 13.0 ----- ----- 18,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ24PAVJU RZR24PVJU BRC1E73 18.5 12.0 ----- ----- 24,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ30PAVJU RZR30PVJU BRC1E73 15.5 9.3 ----- ----- 30,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ36PAVJU RZR36PVJU BRC1E73 17.9 11.4 ----- ----- 36,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164
FCQ42PAVJU RZR42PVJU BRC1E73 17.0 10.3 ----- ----- 40,500 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164

Sky Air Round Flow Ceiling Cassette Heat Pumps


FCQ18PAVJU** RZQ18PVJU9 BRC1E73 18.6 13.0 10.3 ----- 18,000 20,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ24PAVJU RZQ24PVJU9 BRC1E73 18.5 12.0 10.2 ----- 24,000 27,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ30PAVJU RZQ30PVJU BRC1E73 15.5 9.3 10.2 ----- 30,000 34,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FCQ36PAVJU RZQ36PVJU9 BRC1E73 17.9 11.4 9.0 ----- 36,000 40,500 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164
FCQ42PAVJU RZQ42PVJU9 BRC1E73 17.0 10.3 8.6 ----- 42,000 47,000 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164
**FCQ18 1/4 - 1/2 connections. Reduce at the indoor unit
Add Decoration Panel #BYCP125KW1

49
FCQ ROUND FLOW CASSETTE
Specifications
FCQ Series Ceiling Cassette Specifications
Model FCQ18PVJU FCQ24PVJU FCQ30PVJU FCQ36PVJU FCQ42PVJU
Cooling Capacity 18,000 24,000 30,000 36,000 42,000
Heating Capacity 20,000 27,000 34,000 40,000 47,000
Air Flow 390/470/560 470/620/780 530/670/830 700/910/1180 790/970/1220
Sound Pressure 27/30/32 28/32/36 31/35/38 32/38/44 34/40/45
Maximum Over Current Protection 15 15 15 15 15A
Dimensions 9 11/16 x 33 1/16 x 33 1/16 11 5/16 x 33 1/16 x 33 1/16
Weight 43 lb 48.5 lb 55 lb

RZ* Series Outdoor Specifications


Model RZ*18PVJU RZ*24PVJU RZ*30PVJU RZ*36PVJU RZ*42PVJU
Sound Pressure 49/49 58/58
Operating Range Cooling Low 23 - 115
Ambient*
Operating Range Cooling Low 0 - 115
Ambient with Wind Baffle
Operating Range Heating (RZQ) 0 - 77
Maximum Over Current Protection 20 20 20 30 30
Dimensions 30 5/16 x 35 7/16 x 12 5/8 52 15/16 x 35 7/16 x 12 5/8
Weight 150 lb 283 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad (Control is not included with the system) For Low Ambient Cooling Applications
DACAWB3 Wall Bracket BRC1E73 NavigationRemoter Controller KPW5E80 All RZR & RZQ
BRC2A71 Simplified Control (36 & 42 models have 2 fans & require 2 wind baffles)
KRCSO11B Remote Sensor
KRCSPW40 RS Cable 40
KRCSPW80 RS Cable 80
BRC7E82 Wireless Remote Control (FCQ)
AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59

50
FHQ CEILING SUSPENDED Control
Sky Air Not Included*
Page 57

Comfort Convenience Efficiency


Vertical Auto Swing Louvers Self Diagnostic PAM Control
Outdoor Unit Quiet Auto Restart Inverter Technology
Operation Lateral Servicing Space
Dry Mode Allows Installation in Durability
Mold Proof Air Filter Corners Anti-Corrosion Coating
Hot Start & Auto Concealed Piping Daikin Swing Compressor (18 - 30)
Low ambient
Changeover (Heat Pump) Daikin Scroll Compressor (36, 42)
cooling to 0F
Pre Charged for Outdoor
with optional
Unit Only Wind Baffle
Add .55 oz/ft for
additional piping

Timely
FHQ 30-42 A/C FHQ Series
registration
only models are Heat Pumps
is required in
not available in are available
most states
the Southwest in all regions

Single Zone Wall Mount Cooling only

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FHQ18PVJU RZR18PVJU BRC1E73 18.0 14.0 ----- ----- 18,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ24PVJU RZR24PVJU BRC1E73 18.0 12.6 ----- ----- 24,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ30PVJU RZR30PVJU BRC1E73 17.2 10.5 ----- ----- 30,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ36MVJU RZR36PVJU BRC1E73 14.0 10.2 ----- ----- 36,000 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164
FHQ42MVJU RZR42PVJU BRC1E73 14.0 9.5 ----- ----- 40,500 ----- 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164

Sky Air Heat Pump Ceiling Mount

Cooling Heating Control Max. Max.


Indoor Outdoor Control SEER EER HSPF COP Drain Line Set
Btu/h Btu/h Wire Length Height

FHQ18PVJU RZQ18PVJU9 BRC1E73 18.0 14.0 11.1 3.81 18,000 20,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ24PVJU RZQ24PVJU9 BRC1E73 18.0 12.6 10.0 3.38 24,000 27,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ30PVJU RZQ30PVJU BRC1E73 17.2 10.5 8.4 2.67 30,000 34,000 3/4 PVC MSWP1825 MSLS3858**-1/2 164 98
FHQ36MVJU RZQ36PVJU9 BRC1E73 14.0 10.2 8.2 2.68 36,000 37,500 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164
FHQ42MVJU RZQ42PVJU9 BRC1E73 14.0 9.5 8.2 2.69 40,500 39,500 3/4 PVC MSWP1825 MSLS3858**-1/2 230 164

51
FHQ CEILING SUSPENDED
Sky Air
FHQ Series Ceiling Indoor Specifications
Model FHQ18PVJU FHQ24PVJU FHQ30PVJU FHQ36PVJU FHQ42PVJU
Cooling Capacity 18,000 24,000 30,000 36,000 40,500
Heating Capacity 20,000 27,000 34,000 37,500 39,500
Air Flow 670/790 670/790 670/790 670/830 700/850
Maximum Over Current Protection 15 15 15 15 15
Dimensions 7 11/16 x 62 5/8 x 26 3/4
Weight 90 lb

RZQ Series Outdoor Specifications


Model RZ*18PVJU RZ*24PVJU RZ*30PVJU RZ*36PVJU RZ*42PVJU
Sound Pressure 49/49 58/58
Operating Range Cooling Low
23 - 115
Ambient*
Operating Range Cooling Low
0 - 115
Ambient with Wind Baffle
Operating Range Heating 0 - 77
Maximum Over Current Protection 20 20 20 30 30
Dimensions 30 5/16 x 35 7/16 x 12 5/8 52 15/16 x 35 7/16 x 12 5/8
Weight 150 lb 283 lb

Accessories Control Options Wind Baffles


UL16x36 Condenser Pad (Control is not included with the system) For Low Ambient Cooling Applications
DACAWB3 Wall Bracket BRC1E73 NavigationRemoter Controller KPW5E80 All RZR & RZQ
X87721 Condensate Pump BRC2A71 Simplified Control (36 & 42 models have 2 fans & require 2 wind baffles)
T18016 Pump Enclosure KRCSO11B Remote Sensor
KRCSPW40 RS Cable 40
KRCSPW80 RS Cable 80
BRC7E83 Wireless Remote Control (FHQ)
AG3000 Intermatic Surge Protector

More installation supplies & accessories, starting on page 59

52
Applications

Daikin Comfort Easily control


your system from
Control App anywhere in the
world or from the
convenience of your
livingroom.
For Mini-Splits /
SkyAir

Daikin Comfort Control App and Wireless Interface Adapter


for Mini-Splits / SkyAir Products
To download
Scan QR Code

ALWAYS IN CONTROL

It can happen to anyone. You forgot to change


the temperature of your heat pump system or
air conditioner before leaving the house, or you
will be delayed returning home and wish to avoid
needlessly heating or cooling your home. What in
the past would have resulted in wasted energy is
no longer a problem. With the new Daikin Comfort
Control App, you are always in control. You can use
your tablet or smartphone to access your Daikin
system via the internet. Fault conditions can also
be detected remotely, allowing a quick response to
problems.

DAIKIN COMFORT CONTROL APP SCREEN SHOTS

Control individual units or Set a schedule matching Select mode of operation Select Fan mode only when
groups of units conveniently your lifestyle and temperature setting cooling or heating is not
necessary

53
FUNCTIONS ACCESSIBLE VIA THE DAIKIN COMFORT CONTROL APP

AUTO MODE Your Daikin system will change between cooling or heating to maintain the desired
temperature range.

FAN MODE The indoor unit fan will run to circulate the air in the space without cooling or heating

Your Daikin system will only run in heating mode to maintain the desired heating
Heating Mode
temperature

Your Daikin system will only run in cooling mode to maintain the desired cooling
Cooling Mode
temperature

Your Daikin system will continually work to dry the air without affecting the temperature
Dry Mode
in the space

Schedule Adjust or set a schedule remotely

EASY INSTALLATION
It is necessary to install a Wireless Interface Adapter on the indoor unit of the system. WPS (Wireless Protect-
ed Setup) functionality of the adapter allows for quick setup; once the app is launched and the user registers
and logs in, the app will find all connected units within the network. See below list of approved units.

BRP072A43

App functionality requires that a BRP072A43 wireless


Interface Adapter be connected to an approved Daikin
system.
Compatibility
.69 SERIES MODELS
3.11 FTXN_NMVJU,
15
FTKN_NMVJU
2.05 FTX_NMVJU
19
FTK_NMVJU
FTX_NMVJU
20
FVXS_NMVJU

LV FTXS_LVJU

CTXS_LVJU, FTXS_LVJU
MXS/MXL
FVXS_NMVJU
SkyAir FTXS_LVJU

www.daikincomfort.com/DuctlessWireless

PF-WLCA 07-16

54
Daikin ENVi Intelligent Thermostat
DACA-TS1-1

The Daikin ENVi Intelligent Thermostatis the


newest addition to Daikins residential controls
oering. The wall mounted controller features a
backlit LCD display and easy to understand menu
items to be used where the BRC944 wired
remote controller is applicable.
Can be used with:
LV, 15 & 19 Series
Multi-Split System (2 to 8 ports)
Applicable indoor unit models:
FTXS, CTXS, FDXS, and CDXS
15 Series
19 Series

Function
Cool, Heat, and Auto modes with dual setpoints.
Weekly scheduling.
Setback control.
Optimum start.
Hold, Quick save, and Vacation settings.
Fan On/Auto, Fan speed, and Louver direction.
Error code with plain text explanation.

WiFi enabled.
Dealer Web Portal.
WiFi enabled!
Accessible through PC, Smart phone/Tablet
Aux heater control.
Via Dealer Web Portal (Alert Email and Trend Graph).
Display
Standard display.
Room temperature/relative humidity display.
Outdoor temperature and weather forecast.

Other
Backlit
Fahrenheit/Celsius selectable.
Current operation status.
Room temperature sensor.

www.DaikinENVi.com
55
Split Systems Individual Zone Controls
With Daikins super-intelligent, user-friendly system controllers, you can create Absolute Comfort
quickly and easily. Their advanced functionality and easy-to-read liquid crystal displays (LCDs) allow
you to orchestrate and monitor temperature, time, airow volume and more across your entire
system at the touch of button.
Wireless Remote Controller ARC452
This remote controller puts superior comfort at your ngertips.
Frequently used buttons are instantly accessible while other buttons
are under the cover of the remote. A large liquid crystal display panel
makes it easy to read the settings and the On/O button has a raised
dot so that you can feel it in the dark.

Wired Remote Controller BRC944B2 (Option)


This wired remote controller option is for Single Split, Multi-Split,
8-Zone Multi-Split, and SkyAir FTXS system indoor units which
ARC452 wireless remote controller is applicable. The controller
features on/o, operation mode (Cool, Heat, Dry, Auto), setpoint
adjustment, fan speed adjustment, airow direction adjustment,
one-time daily timer. Fahrenheit/Celsius is selectable.

Quaternity Wireless Remote Controller ARC447A3


This infra-red remote controller displays an abundance of functions
such as ambient temperature and room temperature
to set your Quaternity System exactly to your liking.

Wireless Remote Controller BRC7E830 (Option)


This infra-red remote controller, for use with 2 X 2 Ceiling Cassette
FFQ indoor unit, features fan speed control, temperature settings,
and program dry operation.

Navigation Remote Controller BRC1E73 (Option)


This remote controller is compatible with the new 2 X 2 Ceiling
Cassette FFQ indoor unit. The congurable display oers 3 options
with an advanced display great for residential applications and a
simplied display ideal for applications such as hotels wanting to
only provide the necessary buttons to users for comfort without
confusion.

56

20
Navigation Remote Controller (BRC1E73)
The Navigation Remote Controller has been improved to meet the needs of the growing VRV and
SkyAir market. This controller will satisfy almost any controls requirement. The congurable display
and operation buttons will provide as much or as little control as the project requires.

Can be used with: All VRV indoor units and the FAQ, FBQ, FCQ, FHQ, FTQ SkyAir indoor units

Weekly Schedule Guide on Display All Status on Display

BRC1E73 is backwards
compatible and provides all
the features of the existing English/French/Spanish Maintenance Notice Error Notication
Language Selectable
BRC1E71.

Basic Operation
On/O, Operation mode, Setpoint
Fan speed, Airow direction (menu)
Key Functions
Congurable display Standard, Detailed, and Simple (improved)
Dual or single Cool and Heat setpoints for occupied periods (improved)
Independent setback points for unoccupied periods
Unwanted buttons/operation modes can be disabled (improved)
Power o eliminates setpoint and mode adjustment - congurable (improved) Optional face decals
Setpoint range limitation to hide unnecessary
Individual button prohibition (improved) buttons
Auto-changeover for Heat Recovery and Heat Pump systems with dual or single setpoints (improved)
Automatic adjustment for Daylight Savings Time (DST) (improved)
Schedule
Weekly schedule 7 day, weekday plus Saturday and Sunday (5 + 1 + 1), weekday plus weekend (5 + 2)
and Everyday (1) (improved)
Allows programming up to 5 events per day with Cool and Heat or single setpoints

Display Others
Detailed display mode Backlit
Operation mode, Occupied and unoccupied setpoint(s),
Room temperature sensor
Fan speed, Airow direction, Room temperature, Time, Day,
and Status display 12/24 hour clock
Standard display mode Fahrenheit/Celsius selectable
Operation mode, Occupied and unoccupied setpoint(s), Fan speed, English/French/Spanish selectable
and Status display (buttons and system status display are
Simple display mode (new) in English only)
Operation mode, Occupied and unoccupied setpoint(s), Fan speed, Remote control group up to 16
Room temperature indoor units
Optional decal face plate to hide unnecessary buttons (new)
57
System Capabilities Daikin Controls Options

Wireless Remote
BRC1E73 BRC2A71
Controller
Navigation Remote Simplied Wired
(Model depends on
Controller Remote Controller
unit)
Communications 2-Wire / DIII-Net 2-Wire / DIII-Net Infrared
F/C Selector F only F only
Backlit LCD display
Room temperature display
Schedule and setback capabilities (with Time and Date display)
User restriction options
On/O, Operation mode, Setpoint, Fan speed
Louver position adjustment
Reports system malfunctions
Space temperature sensor
Simultaneous operation with Daikin multi-zone controllers
Simultaneous operation with BACnet and LonWorks
Group control capacity Up to 16 indoor Up to 16 indoor Up to 16 indoor
units units units

Auto-changeover Congurable Display Mode Detailed, Standard, Simple


Surely Change to Cooling Display Mode Detailed Standard Simple New
Change to Cooling
(with Guard Timer)
Display image
Cooling SP

On/O status on LED


Heating SP (LED blinks when an error is occurred) X X X
Change to Heating Mode X *1 X *1 X *1
(with Guard Timer) Setpoint (Dual/Single) X *2 X *2 X *2
Surely Change to Heating Room temperature X X
Fan speed X *3 X *3 X *3
Automatic changeover in Heat Pump and Heat Air ow direction
X
Recovery Systems (when a louver is available)
Day and Time X *3
At 1oF above cooling or 1oF below heating Status icon X *3 X *3
setpoint (default) Key lock icon X X
Error message X X
Congurable between 1oF 4oF (improved) *1. OFF can be displayed instead of the operation mode while the unit is turned o with the eld setting (new)
Another 1oF above cooling or 1oF below *2. Can be removed from the display while the unit is turned o with a eld setting (new)
*3. Can be removed from the display with a eld setting (improved)
heating changeover points immediate
changeover ignoring guard timer (new)
Optional Face Decals
Congurable between 1oF 4oF (new)
Single Setpoint Face Decals
Guard timer to prevent frequent mode change
15, 30, 60 (default), or 90 minute guard timer
settable

On/O Display Option

Dual Setpoint Face Decals

58
Mueller Line Sets
PIPING AND ACCESSORIES
Flared Ends Integrated production processes Made in the USA
Rubber Insulation (1/2) eliminate kinking and work-hardening R410A Approved
associated with other line sets

Type Line Set w/ Line Set only


Power & Control Wire*
4 Wire Systems All
Application (Wireless Remote Control) (Power & Control Wire must be added)
Refer to page 60
1/4 x 3/8 x 25 MSLS143814425-1/2 MSLS143825-1/2
1/4 x 3/8 x 50 MSLS143814450-1/2 MSLS143850-1/2
1/4 x 1/2 x 25 MSLS141214425-1/2 MSLS141225-1/2
1/4 x 1/2 x 50 MSLS141214450-1/2 MSLS141250-1/2
1/4 x 5/8 x 25 MSLS145814425-1/2 MSLS145825-1/2
1/4 x 5/8 x 50 MSLS145814450-1/2 MSLS145850-1/2
3/8 x 5/8 x 25 MSLS385814425-1/2 MSLS385825-1/2
3/8 x 5/8 x 50 MSLS385814450-1/2 MSLS385850-1/2
*600V, THHN, 14/4, stranded, no shielded power and control cable
*Sunlight resistant & suitable for direct burial underground.
*Inside the structure, Cable must be contained in conduit (EMT).
*Cable may not be used in a Plenum Space.
See page 58 for more electrical cable options.
INSULATED COPPER TUBING
Plain Ends Insulation is covered with a polyethylene Marked at every foot
Low Density Polyethylene jacket, to protect the insulation during R410A Approved
Closed Cell Foam (1/2) installation
White Insulation is UV resistant & paintable
MUELLER Insulated Copper Tubing
Part Number Description
00470500 MUELLER DURAGUARD COIL 1/4 X 50
00471640 MUELLER DURAGUARD COIL 1/4 X 164
00670500 MUELLER DURAGUARD COIL 3/8 X 50
00671640 MUELLER DURAGUARD COIL 3/8 X 164
00870500 MUELLER DURAGUARD COIL 1/2 X 50
00871640 MUELLER DURAGUARD COIL 1/2 X 164
01070500 MUELLER DURAGUARD COIL 5/8 X 50
01071640 MUELLER DURAGUARD COIL 5/8 X 164
01270820 MUELLER DURAGUARD COIL 3/4 X 82
01470820 MUELLER DURAGUARD COIL 7/8 X 82

ACCESSORIES
Part Number Description
NPER 4102
NPER4102 No-vent caps, pink 5/16, R-410A, 2 Pack
NFP75 3 Wall Sleeve
66731 1/4 x 36 No Kink Hose
66733 3/8 x 36 No Kink Hose
66737 1/2 x 36 No Kink Hose
66735 5/8 x 36 No Kink Hose
66732 3/4 x 36 No Kink Hose
59
NFP 75 NO KINK HOSES
ELECTRICAL ACCESSORIES
Power surges are the silent killer of home appliances and HVAC equipment. Most
homeowners protect their electronics, but leave more valued equipment unsecured.
Surges can wipe out equipment and leave you searching for answers. Search no more.
The easy-to-install AG3000 surge protector is the perfect add-on for HVAC equipment.
It features unmatched surge protection ratings and a 3-year, $7,500 connected
equipment warranty.

Invest in peace of mind with the AG3000!

Surge Protector
Model Service Type of SPD Number of Wiring In Rating MCOV SCCR VPR Enclosure
Voltage Leads Config
L1, L2, L-N 600, L0L
AG3000 120/240 1 pr 2 3 10kA 150/300 20kA 4x
L/N-G 900

4 Wire Systems (Wireless Remote Control & FFQ)


Type TC 600V, THHN, power and control cable
Mini is sunlight resistant & suitable for direct burial underground.
Split must be contained in conduit (EMT) inside the structure.
Cable may not be used in a Plenum Space.
MSW14450 14/4 x 50', 14 ga, 4 Insulated Conductors, Stranded, Not Shielded
MSW144250 14/4 x 250', 14 ga, 4 Insulated Conductors, Stranded, Not Shielded

PVC Coated 600V, THHN, power and control cable


Metal Clad is sunlight resistant & suitable for direct burial underground.
Cable does not require additional conduit inside the structure.
may not be used in a Plenum Space.
58340803 14/4 x 50', 14 ga, 4 Insulated Conductors, Stranded, Not Shielded
58340802 14/4 x 250', 14 ga, 4 Insulated Conductors, Stranded, Not Shielded

2 Wire Systems (Wired Control)


Plenum is not sunlight resistant & is not suitable for direct burial underground.
Rated does not require additional conduit inside the structure.
Control Wire may be used in a Plenum Space.
MSWP1825 18/2 x 500', 18 ga, 2 Insulated Conductors, Stranded, Not Shielded
MSWP1821 14/4 x 1000', 18 ga, 2 Insulated Conductors, Stranded, Not Shielded

Electrical Supplies
Part Number Description
N63124 WHIP 1/2 x 4
N63126 WHIP 1/2 x 6
7711 Disconnect Non Fused
7713 Disconnect 30A Fused
83306 Disconnect 30A Fused Plastic
FRNR 15 15A Fuse
FRNR20 20A Fuse

60
OUTDOOR UNIT INSTALLATION ACCESSORIES
Part Number Description
UL16X36
Ultralite Condenser Pad 16 x 36 x 2
UC16x36x2
UC16x36x3 Ultralite Condenser Pad 16 x 36 x 3
HT1840-4 Cladlite Hurricane Pad 18 x 40 x 4
PDF18 Condenser Rails 18 x 4 x 4 floor supports
PDF39 Condenser Rails 39 x 4 x 4 floor supports
PDFC Condenser Rail caps
87773 Anti Vibration Rubber Mounting Feet 16 x 7 x 4 (ea)

Mounting bracket for mini-split, wall type with top bar, weight capacity not greater than 440 lbs., with
BR440
mounting hardware, 16.5 base leg length

DACAWB3 Mounting Bracket Wall mount kit for up to 500 lbs.


WBB3005 Mounting Bracket - Wall mount kit up to 300 lbs. stainless steel
PCK30 Mounting Bracket - Wall mount kit with cross brace - up to 330 lbs.
87743 Mounting Stand - Flat surface - adjustable uneven surfaces up to 176 lbs.
87746 Mounting Stand - Flat surface - adjustable uneven surfaces up to 440 lbs.
87744 Mounting Stand - Duplex - up to 176 lbs. x 2
87745 Mounting Stand Sloped Roof - up to 45 pitch - up to 250 lbs.

UL16x36
87743(6)
PCK30

PDF BR440 87773

87744 87745

61
ACCESSORIES
PLASTIDUCT
Part Number Size W x D x L Packaging Hide Line Sets/Wiring/Drain
Clips hold tubing in place - UV Resistant - Paintable
PD3 3-1/4 x 2-1/3 x 6-1/2 8 pcs / 52-1/2 ft.
PD4 4-1/3 x 3 x 6-1/2 4 pcs / 26-1/3 ft.
PDCJ3 Cover Joints for PD3 30
PDCJ4 Cover Joints for PD4 20
PDEC3 External Corners for PD3 9
PDEC4 External Corners for PD4 6
PD3/4 PDC3/4 PDT3/4
PDECAP3 End Cap for PD3 9
PDWP3 Wall Passage for PD3 8
PDWP4 Wall Passage for PD4 8
PDC3 Red Clips for PD3 30
PDC4 Green Clips for PD4 20
PDIC3 Internal Corners for PD3 6 PDCJ3/4 PDECAP3 PDWP3/4

PDIC4 Internal Corners for PD4 4


PDFC3 Flat Curve for PD3 8
PDFC4 Flat Curve for PD4 6
PDWE3 Corner Wall Elbow for PD3 6
PDWE4 Corner Wall Elbow for PD4 4 PDEC3/4 PDWE3/4 PDR4
PDT3 T for PD3 4
PDT4 T for PD4 2
PDR4 Reducers for PD4 8

PDIC3/4 PDFC3/4

INSTALLATION TOOLS
Part Number Description
FSG1 Flare Gauge
195FC Clutch Type Flaring Tool
312FC Tube Cutter
N516S 5/16 - 1/4 Hose Adapter
TLB410AUR Tool Kit for R-410A Mini-Splits
Kit includes: Clutch type flaring tool, Metric & SAE Torque Wrench
set, SAE & Metric Hex Tools, Valve Core Tool, Straight Brass Adapters
5/16-1/4, Angled Brass Adapters and Brass Caps (5/16) in a canvas
tool bag.
97705 Mighty Bracket Installation Support Tool
DLS-CABLE BACnet/LON Works Commissioning Cable

62
CONDENSATE MANAGEMENT ACCESSORIES
CONDENSATE PUMPS
Part Number Description
X85003 Microblue Blue Diamond 230V 1.3GPH, 16.4 Head, 6.5 Suction, X85003
Fits in Drain Pan up to 1.5 Ton
X87721 Maxi Blue 230 Blue Diamond Condensate pump 230V, 3.7GPH, 23 head, 16.5
suction, 21 dB, Integral alarm, 3 year warranty, up to 48,000 BTV
T18016 Fascia Kit For X85003 + X87721 - Mounts below the unit
X87835 Mega Blue Blue Diamond Condensate pump Uni volt, 13.2GPH, 66.5 head, 23 suction
self priming, 22 dB, Integral alarm, 3 year warranty, up to 48,000 BTV
C21014 Blue Diamond Multi Unit Tank

C13103 Blue Diamond 16 Sensor Cable Extension


T18016
C13192 Blue Diamond Alarm Extension Cable

F10011 Blue Diamond Mounting Feet (Pair)


Sauermann SI-30 Condensate Pump, 208/230 VAC, GPH @ 0 Head, Blue Diamond
DACACP3-1 SI302 GPH @ 33 Head, Maximum Head: 33, Maximum Suction Head: 10,
Sound Level @ 3.3: 20 dBA Plenum Rated
Condensate
DACACFS1 97622 Condensate Float switch for wall mounted units (SS610E) Pumps

DRAIN TUBING
Part Number Description
58VT 5/8 Vinyl Tubing
DH-16 Corrugated No Kink Drain Tubing 5/8x164
83020 Adapter 16mm Hose (5/8) to 1/2 PVC
EZT180 Waterless 16mm (5/8) in Line Mini Trap
DHJ16 Coupling DH-16 to DH-16 DH-16 83020

DHJ16 EZT 180

63
Daikin
DaikinMini-Split
Mini-SplitWiring
WiringDiagram
Diagram
230V
230V4-Wire
4-WireRemote
RemoteControl
ControlSystems
Systemswith
withCondensate
CondensatePump
Pump
Daikin Wiring Diagram
230V 4-Wire Remote Control Systems with Condensate Pump

Daikin
DaikinSkyAir
SkyAirWiring
WiringDiagram
Diagram
230V
230VWired
WiredControl
ControlSystems
Systemswith
withCondensate
CondensatePump
Pump
Daikin Wiring Diagram
230V Wired Control Systems with Condensate Pump

25
25

64
SERVICE TOOLS
Part Number Description
999158T Daikin Service Checker For DIII Net Systems (Service Training Required)
999153T Inverter Analyzer (new)
99S0038 EEV Manual Coil Checker
999154T DC Fan Motor Checker
999482P D-CHECKER Analyzer for Inverter Systems
1368514 Transmission Monitor
4678571 Refco Inverter Tester. This kit can indicate correctly operating inverter
power stages, as well as the serial-link communication between the
condensing unit and the indoor units. The kit contains the electronic
module with a set of leads as well as a selection of cables.
417175 NuCalgon Evap Foam Spray Can (18 oz) No Rinse Coil Cleaner
MSB-KIT Speed clean mini split bib kit keeps walls and valuables safe from
water and chemicals.
Kit includes: bracket, bib, adjustable cord, support Rib, deflector
plates (1 short & 1 long), adhesive wrap, and a 5 gallon bucket
MSB-01 Replacement bib
82560 Rectorseal ductless cleaning kit. Kit includes: 1 gallon desolv cleaning
solution, frame, wedge (2), (2) single use bags and a 5 gallon bucket
82562 Rectorseal single use replacement bags

65
TRAINING CLASSES
Ductless Single & Multi-Split Systems Key Sales Points Ductless RLC Service & Troubleshooting (4-wire)
This presentation provides the key selling points on Daikin Residential 4-wire Service & Troubleshooting. Course Objectives
equipment. Review installation & start up basics. (Prerequisite: Ductless &
Multi & Split Installation)
Ductless Single & Multi-Split Key Points of Installation Type: Classroom
Single & Multi-Split Key Points of the Installation Process.
Type: Classroom Ductless RLC Product & Applications
Residential Light Commercial (4- and 2-wire).
Ductless 8-Zone Multi-Split Key Points of Installation Type: Classroom
The 8-Zone Multi-Split Key Points of the Installation Process
provides the information needed to install the Daikin 8-Zone Multi. Ductless RLC Install & Start Up 8hr (4-wire)
Type: Classroom Residential 4-wire systems Course Objectives Daikin AC
Introduction & history 4-wire systems product.
SkyAir Key Points of Installation RZR/RZQ (2-wire) & Type: Classroom
RXS/RKS (4-wire)
The module covers the Key Points of Installation for Daikin Sky Air VRV Training Classes are available at United
Systems. Refrigeration Training Centers, for United Refrigeration
Type: Classroom VRV Pro Dealers
Check with your local branch for details.

66
DR. DAIKIN
FAULT CODE DIAGNOSIS
Online Mobile Text
Go to www.DrDaikin.com Send error and the fault code to
Enter the fault code 32075
Check the disclaimer box - Example: error a3
Click on the Blue arrow - Note 1: type the word error - space -
Wait for the diagnosis then the fault code
- What does the fault code mean? - Note 2: the letters are not case
- Which unit produced the fault code sensitive
- See up to four likely causes Wait 30 seconds for a return text with
On Your Smart Phone the diagnosis
Go to www.mobile.drdaikin.com
Enter the fault code
Check the disclaimer box
Click on the Blue arrow
Wait for the Diagnosis

Fault Diagnosis from the Remote Controller

Press and hold the Timer Cancel button (A) for 5 seconds to
activate the service check function and a long beep will sound
from the indoor unit.
B
The temperature display on the remotes LCD display flashes
00 (B). As you continue to press the Cancel button, error
codes will continue to display with a short beep.

Press the Timer Cancel button (A) repeatedly until a long


beep is heard.

The temperature display changes from flashing 00 to the last


fault code stored in memory (B).

Press and hold the Timer Cancel button (A) for 5 seconds to
deactivate the service check function.

Service check mode will cancel automatically after 1 minute.

Your remote controller may


look slightly different but
same steps apply.
67
2017
Ducted & Ductless
Single Phase Inverter
Single Phase VRV
& Three Phase VRV
Comfort Systems

UNITED REFRIGERATION - CORPORATE HEADQUARTERS


11401 ROOSEVELT BOULEVARD
PHILADELPHIA, PA 19154
Revision 1, April 1, 2017 PHONE: (888) 578-9100 www.uri.com

You might also like