Title page

Alcatel-Lucent 9311
Macro V2 Node B Indoor | UA08.1
Preventive Maintenance
NN-20500-008
Issue 09.07 | January 2013

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements

Legal notice

Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents

About this document


Purpose ............................................................................................................................................................................................. xi
xi

Reason for reissue ........................................................................................................................................................................ xi


xi

New in this release ....................................................................................................................................................................... xi


xi

Intended audience ......................................................................................................................................................................... xi


xi

Supported systems ...................................................................................................................................................................... xii


xii

How to use this document ........................................................................................................................................................ xii


xii

Safety information ...................................................................................................................................................................... xii


xii

Prerequisites .................................................................................................................................................................................. xii


xii

Conventions used ........................................................................................................................................................................ xii


xii

Related information ................................................................................................................................................................... xiii


xiii

Document support ...................................................................................................................................................................... xiv


xiv

Technical support ....................................................................................................................................................................... xiv


xiv

How to order ................................................................................................................................................................................ xiv


xiv

How to comment ........................................................................................................................................................................ xiv


xiv

1 Roadmap to Conventional Base Station documentation

Overview ...................................................................................................................................................................................... 1-1


1-1

Roadmap to Conventional Base Station documentation ............................................................................................ 1-2


1-2

2 Safety statements

Overview ...................................................................................................................................................................................... 2-1


2-1

Structure of safety statements ............................................................................................................................................... 2-2


2-2

3 Preventive maintenance activity

Overview ...................................................................................................................................................................................... 3-1


3-1
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary iii
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................
Preventive maintenance activity .......................................................................................................................................... 3-2
3-2

4 9311 Macro V2 ID introduction

Overview ...................................................................................................................................................................................... 4-1


4-1

9311 Macro V2 ID introduction .......................................................................................................................................... 4-2


4-2

5 9311 Macro V2 ID hardware presentation

Overview ...................................................................................................................................................................................... 5-1


5-1

9311 Macro V2 ID hardware presentation ....................................................................................................................... 5-2


5-2

6 Checking the door alarm

Overview ...................................................................................................................................................................................... 6-1


6-1

Checking the door alarm ........................................................................................................................................................ 6-2


6-2

7 9311 Macro V2 ID power down and power up procedures

Overview ...................................................................................................................................................................................... 7-1


7-1

Powering down a 9311 Macro V2 ID ................................................................................................................................ 7-2


7-2

Powering up a 9311 Macro V2 ID ...................................................................................................................................... 7-5


7-5

8 9311 Macro V2 ID preventive maintenance procedures

Overview ...................................................................................................................................................................................... 8-1


8-1

Inspecting air filter, intake and exhaust grids ................................................................................................................. 8-2


8-2

Inspecting the cabinet seals ................................................................................................................................................... 8-4


8-4

Inspecting the RF connectors ............................................................................................................................................... 8-5


8-5

Inspecting the anchor bolts ................................................................................................................................................. 8-10


8-10

A Product conformance statements

Overview ..................................................................................................................................................................................... A-1


A-1

European regulatory requirement compliance .............................................................................................................. A-2


A-2

North American regulatory requirements compliance ............................................................................................... A-4


A-4

Compliances for other regions/countries ........................................................................................................................ A-8


A-8

Operational conditions ........................................................................................................................................................... A-9


A-9
....................................................................................................................................................................................................................................
iv Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................
Cable specifications .............................................................................................................................................................. A-10
A-10

Product labelling .................................................................................................................................................................... A-11


A-11

Index

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary v
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
vi Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
List of tables

1 Generic terms ............................................................................................................................................................... xii


xii

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary vii
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
List of tables

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
viii Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
List of figures

1-1 Roadmap to Conventional Base Station documentation ............................................................................. 1-3

4-1 9311 Macro V2 ID outside view .......................................................................................................................... 4-4

5-1 9311 Macro V2 ID general view .......................................................................................................................... 5-3

5-2 9311 Macro V2 ID cabinet layout (with MCPA + DDM + TRM) .......................................................... 5-4

5-3 9311 Macro V2 ID cabinet layout (with TRDU) ........................................................................................... 5-5

5-4 9311 Macro V2 ID bulkhead top view ............................................................................................................... 5-6

7-1 DC breaker module ................................................................................................................................................... 7-3


7-3

7-2 DC breaker module ................................................................................................................................................... 7-5


7-5

8-1 9311 Macro ID outside view ................................................................................................................................. 8-2

8-2 STSR2 wiring configuration in a 9311 Macro ID ( configuration MCPA+TRM+DDM) .............. 8-6

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary ix
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
x Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
About this document
About this document

Purpose
The purpose of this document is to describe the preventive maintenance procedures
applicable to the Alcatel-Lucent 9311Macro V2 Node B Indoor cabinet.

Reason for reissue


The reissue reasons are:

Issue number Issue date Reason for reissue


09.07 January 2013 Standard Issue
09.06 November 2012 Standard Issue
09.05 October 2012 Standard Issue
09.04 March 2012 Preliminary issue
09.03 November 2011 Preliminary issue
09.02 September 2011 Preliminary issue
09.01 June 2011 Draft issue

New in this release


New features:
121167 Support of remote MC-TRX from 9100 MBS.
Other changes:
Updated documentation roadmap
Important! The availability of the features listed above on the hardware equipment
should be checked with your Alcatel-Lucent representative.

Intended audience
The audience for this document is Operations and maintenance personnel, and for those
who want to know the principles of Node B preventive maintenance.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary xi
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................
Supported systems
This document applies to Alcatel-Lucent W-CDMA UA08.1 system release.

How to use this document


No specific recommendation applies regarding the way readers should read this
document.

Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.

Prerequisites
It is recommended that readers become familiar with the following publication:
Alcatel-Lucent 9311 Macro V2 Node B Indoor - Technical Description, NN-20500-003

Conventions used
.
Vocabulary conventions
For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, NN-20500-002
This document uses some terms generically.

Table 1 Generic terms

Generic term Used for


CCM CCM/iCCM/iCCM-2/xCCM
CEM iCEM/iCEM-2/xCEM/eCEM
TRM TRM/iTRM/xTRM/xTRM-2
DDM DDM/DDM-2/AISG DDM
MCPA MCPA 850/MCPA 2100/MCPA-2
2100/MCPA-3 2100/MCPA 60W 850/MCPA
60W 2100
SCPA SCPA 900 55W
TRDU TRDU60-21/TRDU60-21B

....................................................................................................................................................................................................................................
xii Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................
Typographical conventions
The following typographical conventions are used in this document:

Appearance Description
IP reference, reference number Related document that is referenced in the document
bold text Emphasized information

Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:

Refer to this document At this location For more information on


Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Terms used in Alcatel-Lucent
System - Terminology, com. 9300 W-CDMA documents.
NN-20500-002
Alcatel-Lucent 9353 http://support.alcatel-lucent. Alarm descriptions and
Wireless Management com. maintenance actions required
System - Node B Alarms for Alcatel-Lucent Node Bs
Reference Guide for 9311,
9312, 9322, 9326, 9332
Node B, NN-20500-018P1
Alcatel-Lucent 9353 http://support.alcatel-lucent. Performing Graphical User
Wireless Management com. Interface (GUI) commands
System - User Guide, available in the Wireless
NN-20500-032 Management System (WMS)
solution.
Alcatel-Lucent 9100 and http://support.alcatel-lucent. Performing the Node B
93xx Node B - com. installation, commissioning
Commissioning and Fault and maintenance tasks using
Management User the Node B TIL (Terminal for
Manual: TIL, Local Installation) tool.
NN-20500-019
Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Safety guidelines and the
safety guide, 401-382-880 com. catalog of hazard statements
that appear in the
Alcatel-Lucent UMTS
customer documents.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary xiii
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
1-888-582-3688 (for the United States)
1-630-224-2485 (for all other countries)

Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.

How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)

How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).

....................................................................................................................................................................................................................................
xiv Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
1 1oadmap to Conventional
R
Base Station
documentation

Overview
Purpose
This chapter provides the roadmap for Conventional Base Station documentation.

Contents

Roadmap to Conventional Base Station documentation 1-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 1-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

Roadmap to Conventional Base Station documentation


Overall roadmap
For the roadmap relating to the full documentation collection, see:
Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050
For the Access Network Elements Overview, see:
Alcatel-Lucent W-CDMA System - Access Network Elements Overview,
NN-20500-233

....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

Figure 1-1 Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 1-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
2 Safety statements
2

Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.

Contents

Structure of safety statements 2-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 2-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................

Structure of safety statements


Overview
This topic describes the components of safety statements that appear in this document.

General structure
Safety statements include the following structural elements:

B C D
CAUTION

MP L E
Lifting hazard E F

SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)

....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:

Signal word Meaning


DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 2-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
3 3reventive maintenance
P
activity

Overview
Purpose
This chapter describes the preventive maintenance activity applicable to the 9311 Macro
ID cabinets.

Contents

Preventive maintenance activity 3-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 3-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Preventive maintenance activity Preventive maintenance activity

....................................................................................................................................................................................................................................

Preventive maintenance activity


Preventive maintenance
The preventive maintenance is used to periodically test the items of equipment that do not
directly trigger any alarm at the OMC. However, the execution of preventive maintenance
procedures can trigger alarms at the OMC.
These procedures must be performed according to the following schedules.
It is possible to group some of the procedures, which reduces the intervention time. The
intervention time indicated corresponds to the intervention time for each item of
equipment.
Note: In certain environments, these procedures may be required more frequently:
In dusty or dirty environments the fan filter may need to be replaced more
frequently.
Environmental conditions and door opening-closing frequency may impact the
door gasket ageing.
Systems located in high seismic areas may require anchor bolts and mounting
hardware to be tightened periodically especially for field installed items.
Antenna mounts and connectors may require periodic cleaning in dirty and high
humidity areas.

Preventive maintenance schedule for the 9311 Macro V2 ID equipment

Procedure Periodic- Test Duration Tools Recom- Replace-


ity (approx.) required mended ment
Replacement Sheet
Schedule
Checking the door alarm Every site Two minutes None N/A
(p. 6-2) visit
Inspecting air filter, intake Every site Two minutes None N/A
and exhaust grids (p. 8-2) visit or at
least once
a year
Inspecting the cabinet seals Every site Two minutes None N/A
(p. 8-4) visit or at
least once
a year

....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Preventive maintenance activity Preventive maintenance activity

....................................................................................................................................................................................................................................

Procedure Periodic- Test Duration Tools Recom- Replace-


ity (approx.) required mended ment
Replacement Sheet
Schedule
Inspecting the RF Every two One hour Flat N/A
connectors (p. 8-5) years screwdriv-
ers
7/16
torque
wrench
Inspecting the anchor bolts Only for 20 minutes Flat N/A
(p. 8-10) seismic maximum, screw-
zone: depending on driver
every site accessibility Wrench
visit
Powering down a 9311 When Two minutes None N/A
Macro V2 ID (p. 7-2) needed
Powering up a 9311 Macro When Three minutes None N/A
V2 ID (p. 7-5) needed

Preliminary checks before performing preventive maintenance procedures

WARNING
Personal injury hazard
The personnel working on the cabinet must be authorized to work according to the
applicable safety standards

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 3-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Preventive maintenance activity Preventive maintenance activity

....................................................................................................................................................................................................................................
NOTICE
Equipment damage hazard
Missing panels, covers or blank slot filler modules may lead to incorrect cooling and loss
of EMI integrity. Ensure all covers, panels and filler modules are fitted correctly

Description of a preventive maintenance procedure


A preventive maintenance procedure is divided into the following parts:
The title
The main body with the following information:
Intervention time
Tools required
Step-by-step actions
One or more figures

....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
4 4311 Macro V2 ID
9
introduction

Overview
Purpose
This part gives an overview of the Alcatel-Lucent 9311Macro V2 Node B Indoor

Contents

9311 Macro V2 ID introduction 4-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 4-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID introduction 9311 Macro V2 ID introduction

....................................................................................................................................................................................................................................

9311 Macro V2 ID introduction


Introduction
The 9311 Macro V2 ID is an ETSI UMTS Node B element and it supports the Iub
interface.
The 9311 Macro V2 ID only supports the Frequency Division Duplex (FDD) mode.
The 9311 Macro V2 ID is responsible for radio transmission/reception from/to one or
more cells to/from the User Equipment (UE).
The 9311 Macro V2 ID provides:
The means of communication between a UE and a network using Transport Channels
Physical layer channels which are necessary to synchronize the downlink and also to
perform cell selection/reselection and hand over preparation
Measurement information to the RNC for radio resource management (handover,
power control)
The 9311 Macro V2 ID provides up to eight E1/T1 (only T1 for UMTS 850) with
Inversion Multiplexing ATM (IMA) or Drop and Insert capability (fractional E1/T1). The
9311 Macro V2 ID also supports multi-PCM without IMA, IP, and Microwave Packet
Radio (MPR).

9311 Macro V2 ID interfaces


The 9311 Macro V2 ID provides the following interfaces:
Uu interface (UMTS User interface): this interface is used between the Node B and
the UE. It is dependent on the technology used on the radio (for example, it can be
W-CDMA or TD/CDMA).
Iub interface (Interface Node B): this interface lies between the RNC and the 9311
Macro V2 ID. It allows to connect RNCs.

9311 Macro V2 ID cabinet


The 9311 Macro V2 ID cabinet is a single 600 mm wide cabinet closed by one door. It is
designed for ease of manufacture, transportation, installation, system assembly, repair and
testing.
The 9311 Macro V2 ID cabinet must be installed in an air conditioned environment.
It has been designed to improve mechanical and acoustic performance.
The 9311 Macro V2 ID can operate into the following bandwidths:
2100 MHz
1900 MHz
900 MHz
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID introduction 9311 Macro V2 ID introduction

....................................................................................................................................................................................................................................
850 MHz
2100/900 MHz (dual-band)
2100/850 MHz (dual-band)
1900/850 MHz (dual-band)
The 9311 Macro V2 ID, when using an xCOB module or d4U as digital equipment with
TRDU, can operate in the 2100 MHz frequency band only.
The 9311 Macro V2 ID hardware is High Speed Downlink Packet Access (HSDPA)
ready.
The following figure shows the outside view of the 9311 Macro V2 ID cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 4-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID introduction 9311 Macro V2 ID introduction

....................................................................................................................................................................................................................................

Figure 4-1 9311 Macro V2 ID outside view

9311 Macro V2 ID modules


The alpha-modules were the first generation of modules delivered by Alcatel-Lucent. The
alpha-CEM is not supported since UA06.0.

....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID introduction 9311 Macro V2 ID introduction

....................................................................................................................................................................................................................................
Then Alcatel-Lucent delivered a second generation of modules:
iModules (also called beta-modules) and iModules-2
These modules are compatible with existing ones. They are transparent to the user as
they do not provide a capacity change (except for iCEM).
MCPA-2
The MCPA-2 module operates into the 2100 bandwidth.
The third generation of modules delivered by Alcatel-Lucent were the following:
xTRM
MCPA-3
The MCPA-3 module operates into the 2100 bandwidth.
The fourth generation of modules delivered by Alcatel-Lucent were the following:
xTRM-2
The xTRM-2 module operates into the 2100 bandwidth.
xCCM
xCEM
eCCM-U
eCEM
eCEM-U
MCPA 60W
The MCPA 60W module operates into the 2100 and 850 bandwidths.
SCPA 55W
The SCPA 55W module operates into the 900 bandwidth.
DDM-E
The DDM-E module operates into the 900 bandwidth.
DDM-P
The DDM-P module operates into the 900 bandwidth.
eCEM
xCOB
TRDU
The TRDU module operates into the 2100 bandwidth.
The latest generation of modules proposed in 9311 Macro V2 ID, after cabinet renovation
with a d4U digital rack, is based on following modules:
xCCM-U or eCCM-U module for controller
xCEM-U or eCEM-U module for modem
TRDU
The TRDU module operates into the 2100 bandwidth.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 4-5
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID introduction 9311 Macro V2 ID introduction

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
4-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
5 5311 Macro V2 ID
9
hardware presentation

Overview
Purpose
This part presents the hardware into the following 9311 Macro V2 ID cabinets:
9311 Macro V2 ID 2100
9311 Macro V2 ID 1900
9311 Macro V2 ID 900
9311 Macro V2 ID 850
9311 Macro V2 ID 2100/900
9311 Macro V2 ID 2100/850
9311 Macro V2 ID 1900/850

Contents

9311 Macro V2 ID hardware presentation 5-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 5-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................

9311 Macro V2 ID hardware presentation


9311 Macro V2 ID 2100 hardware presentation
The 9311 Macro V2 ID 2100 cabinet is composed of the following elements:
One DDM shelf (up to three DDMs)
One MCPA shelf (up to six MCPAs or TRDU)
One InterCOnnection (ICO) module
One digital shelf
One DC module which houses the Interco breaker, the cooling unit breaker, and the
digital breaker
One Indoor External Alarm (IEA) module
One MCA module
One cooling unit
The cooling unit is located at the bottom of the cabinet. The cabinet is cooled by the
convection through a single open forced ventilation unit.
Note: All modules are accessible by their front only.
The cooling unit is accessible through the protection panel.
The 9311 Macro V2 ID 2100 cabinet supplies a fixed -48 V DC electrical distribution to
power the installed electronic equipment.
The following figures show the 9311 Macro V2 ID inside view and layout.

....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................

Figure 5-1 9311 Macro V2 ID general view

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 5-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................
Figure 5-2 9311 Macro V2 ID cabinet layout (with MCPA + DDM + TRM)

....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................
Figure 5-3 9311 Macro V2 ID cabinet layout (with TRDU)

All cables enter the 9311 Macro V2 ID from a cable bulkhead located on top of the
cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 5-5
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................
The following figure shows the 9311 Macro V2 ID bulkhead.

Figure 5-4 9311 Macro V2 ID bulkhead top view

9311 Macro V2 ID 1900 hardware presentation


The 9311 Macro V2 ID 1900 hardware is similar to the 9311 Macro V2 ID 2100
hardware, except for the following components:
The RF block houses the modules that operate in the 1900 MHz frequency band.
These modules are the following:
MCPA 1900 modules
DDM 1900 modules
The digital shelf houses the TRM/iTRM 1900 modules.
The 9311 Macro V2 ID 1900 supports +24 V DC (optional). This option allows you to
connect the 9311 Macro V2 ID 1900 to a +24 V DC power feed.

....................................................................................................................................................................................................................................
5-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................
9311 Macro V2 ID 900 hardware presentation
The 9311 Macro V2 ID 900 hardware is similar to the 9311 Macro V2 ID 2100 hardware,
except for the following components:
The RF block houses the modules that operate in the 900 MHz frequency band. These
modules are the following:
One-carrier SCPA 900 55W modules
DDM-E 900 and DDM-P 900 modules
The digital shelf houses the two-carrier xTRM 900 modules.
Note: The 9311 Macro V2 ID 900 does not support the following:
Mix of DDM-E and DDM-P modules
Reduced mode for MaxPowerAmplification
OTSR, OTBR, and STSR2 configurations
RRH
AISG

9311 Macro V2 ID 850 hardware presentation


The 9311 Macro V2 ID 850 hardware is similar to the 9311 Macro V2 ID 2100 hardware,
except for the following components:
The RF block houses the modules that operate in the 850 MHz frequency band. These
modules are the following:
MCPA 850 modules
DDM 850 modules
The digital shelf houses the xTRM 850 modules.

9311 Macro V2 ID 2100/900 hardware presentation


The 9311 Macro V2 ID 2100/900 hardware is similar to the 9311 Macro V2 ID 2100
hardware, with dedicated (bandwidth-specific) and shared modules:
Dedicated modules:
For 2100 MHz: TRM/iTRM/xTRM 2100 + MCPA/MCPA-2/MCPA-3/MCPA
60W 2100 + DDM/DDM-2 2100
For 900 MHz: xTRM 900 + SCPA 55W + DDM-E 900/DDM-P 900
Shared modules: GPSAM, GPxOIM, iCEM/iCEM-2/xCEM/eCEM,
iCCM/iCCM-2/xCCM

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 5-7
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID hardware presentation 9311 Macro V2 ID hardware presentation

....................................................................................................................................................................................................................................
9311 Macro V2 ID 2100/850 hardware presentation
The 9311 Macro V2 ID 2100/850 hardware is similar to the 9311 Macro V2 ID 2100
hardware, with dedicated (bandwidth-specific) and shared modules:
Dedicated modules:
For 2100 MHz: TRM/iTRM/xTRM 2100 + MCPA/MCPA-2/MCPA-3/MCPA
60W 2100 + DDM/DDM-2 2100
For 850 MHz: TRM/iTRM/xTRM 850 + MCPA/MCPA 60W 850 + DDM 850
Shared modules: GPSAM, GPxOIM, iCEM/iCEM-2/xCEM/eCEM,
iCCM/iCCM-2/xCCM

9311 Macro V2 ID 1900/850 hardware presentation


The 9311 Macro V2 ID 1900/850 hardware is similar to the 9311 Macro V2 ID 2100
hardware, with dedicated (bandwidth-specific) and shared modules:
Dedicated modules:
For 1900 MHz: TRM/iTRM 1900 + MCPA 1900 + DDM 1900
For 850 MHz: TRM/iTRM/xTRM 850 + MCPA/MCPA 60W 850 + DDM 850

....................................................................................................................................................................................................................................
5-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
6 Checking the door alarm
6

Overview
Purpose
This part describes how to check the door alarm.

Contents

Checking the door alarm 6-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 6-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Checking the door alarm Checking the door alarm

....................................................................................................................................................................................................................................

Checking the door alarm


Purpose
The purpose of this procedure is to check the door intrusion alarm that is generated when
the Node B doors are opened.

Intervention time
Two minutes

Tools required
None
Important! This procedure requires to be in contact with the OMC administrator.
Important! For outdoor models, do not forget to ask the site manager for the Node B
key.

Procedure
...................................................................................................................................................................................................

1 Contact the OMC administrator to check that the door alarm is OFF.
...................................................................................................................................................................................................

2 Open the Node B door(s) to activate the door alarm.


...................................................................................................................................................................................................

3 An alarm must be observed at the OMC. Request confirmation from the OMC
administrator.
...................................................................................................................................................................................................

4 Close the Node B door(s).


...................................................................................................................................................................................................

5 Check with the OMC administrator that the door alarm is OFF.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
7 7311 Macro V2 ID power
9
down and power up
procedures

Overview
Purpose
This part describes how to power down and power up the 9311 Macro V2 ID cabinets.

Contents

Powering down a 9311 Macro V2 ID 7-2


Powering up a 9311 Macro V2 ID 7-5

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 7-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID power down and power up procedures Powering down a 9311 Macro V2 ID

....................................................................................................................................................................................................................................

Powering down a 9311 Macro V2 ID


Purpose
Perform the following procedure to power down a 9311 Macro V2 ID.

Preliminary operations
Make sure the state of the btsSiteManager object is "locked". For more information about
the OMC, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.
Important! Do not forget to ask the site manager for the Node B key.
Important! If a DC power down of the equipment is required, notify the site manager
then locate the DC power supply on the customer site. Disconnect and lock out the
DC main power supply before servicing the equipment.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Switch OFF the Digital breaker (4).

....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID power down and power up procedures Powering down a 9311 Macro V2 ID

....................................................................................................................................................................................................................................

Figure 7-1 DC breaker module

...................................................................................................................................................................................................

3 Switch each MCPA/SCPA module breaker to the O position.


Result: The red LED of each MCPA/SCPA module is OFF.
...................................................................................................................................................................................................

4 Switch OFF the Interco breaker (2).


...................................................................................................................................................................................................

5 Switch OFF the Cooling Unit breaker (3).


...................................................................................................................................................................................................

6 Wait five seconds minimum until the fans stop.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 7-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID power down and power up procedures Powering down a 9311 Macro V2 ID

....................................................................................................................................................................................................................................
Result: The three green LEDs are OFF. The fans stop.
...................................................................................................................................................................................................

7 At the customer DC power supply, switch OFF the cabinet circuit breaker.
...................................................................................................................................................................................................

8 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID power down and power up procedures Powering up a 9311 Macro V2 ID

....................................................................................................................................................................................................................................

Powering up a 9311 Macro V2 ID


Purpose
Perform the following procedure to power up a 9311 Macro V2 ID.

Tools required
Local Installation Terminal (TIL)

Preliminary operations
Open the Node B door and check the following:
The three circuit breakers on the DC module are switched OFF (see Figure 7-2, DC
breaker module (p. 7-5)).
All MCPA/SCPA module breakers are in the O position.

Figure 7-2 DC breaker module

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 7-5
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID power down and power up procedures Powering up a 9311 Macro V2 ID

....................................................................................................................................................................................................................................

Important! This procedure requires to be in contact with the OMC administrator.


Important! Do not forget to ask the site manager for the Node B key.
Important! If a DC power is required, locate the DC power supply on the customer
site and notify the site manager of the Node B start up.

Procedure
...................................................................................................................................................................................................

1 At the customer DC power supply, switch ON the 9311 Macro V2 ID circuit breaker.
...................................................................................................................................................................................................

2 Switch ON the Cooling Unit breaker (3).


...................................................................................................................................................................................................

3 Wait five seconds minimum until the fans start.


Result: The three green Light Emitting Diodes (LED) are lit. The fans start up.
...................................................................................................................................................................................................

4 Switch ON the Interco breaker (2).


...................................................................................................................................................................................................

5 Wait five seconds minimum.


...................................................................................................................................................................................................

6 Switch each MCPA/SCPA module breaker to the I position.


Result: The red LED of each MCPA/SCPA module is lit.
...................................................................................................................................................................................................

7 Switch ON the Digital breaker (4).


...................................................................................................................................................................................................

8 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

9 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
8 8311 Macro V2 ID
9
preventive maintenance
procedures

Overview
Purpose
This part contains the preventive maintenance procedures applicable to the 9311 Macro
V2 ID.

Contents

Inspecting air filter, intake and exhaust grids 8-2


Inspecting the cabinet seals 8-4
Inspecting the RF connectors 8-5
Inspecting the anchor bolts 8-10

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting air filter, intake and exhaust grids

....................................................................................................................................................................................................................................

Inspecting air filter, intake and exhaust grids


Purpose
Carry out the following procedure to inspect air filter, intake and exhaust grids in the
9311 Macro ID.

Figure 8-1 9311 Macro ID outside view

....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting air filter, intake and exhaust grids

....................................................................................................................................................................................................................................
Note: The intake grid is at the bottom of the Node B door; the exhaust grid is on top
of the Node B.

Intervention time
Two minutes

Tools required
None
Important! This procedure requires to be in contact with the OMC administrator.
Important! Do not forget to ask the site manager for the Node B key.

Procedure
...................................................................................................................................................................................................

1 Check that no object impedes air flow through the bottom intake grid.
...................................................................................................................................................................................................

2 Open the Node B door and check the air filter behind the bottom intake grid.
Note: To replace the air filter, please refer to Replacing the ICU air filter of the 9311
Macro ID in Alcatel-Lucent 9311 Macro Node B Indoor Corrective Maintenance,
NN-20500-009
...................................................................................................................................................................................................

3 Check that no object covers up the top exhaust grid.


...................................................................................................................................................................................................

4 Check that both grids are clear of debris.


...................................................................................................................................................................................................

5 Clean the grids, if necessary.


...................................................................................................................................................................................................

6 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the cabinet seals

....................................................................................................................................................................................................................................

Inspecting the cabinet seals


Purpose
Carry out the following procedure to inspect cabinet seals in the 9311 Macro V2 ID.

Intervention time
Two minutes

Tools required
None
Important! Do not forget to ask the site manager for the Node B key.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Ensure good all-around seal containment.


...................................................................................................................................................................................................

3 Check seals for damage such as tearing or cracking.


...................................................................................................................................................................................................

4 Repair or replace, if necessary.


Note: Cabinet seals for the 9311 Macro V2 ID are not required for environmental
issues, such as water ingress and condensation. The seals provide EMI protection and
assist with overall noise reduction.
...................................................................................................................................................................................................

5 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the RF connectors

....................................................................................................................................................................................................................................

Inspecting the RF connectors


Purpose
Carry out the following procedure to inspect the RF connectors in the 9311 Macro ID
(configuration MCPA +TRM+DDM).
Note: In the following procedure, the generic term DDM is used for DDM/DDM-2,
TRM is used for TRM/iTRM/xTRM/xTRM-2, and CCM is used for
CCM/iCCM/xCCM.

Intervention time
One hour

Tools required
Flat screwdriver
SMA torque wrench
7/16 torque wrench
N torque wrench

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-5
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the RF connectors

....................................................................................................................................................................................................................................

Figure 8-2 STSR2 wiring configuration in a 9311 Macro ID ( configuration


MCPA+TRM+DDM)

WARNING
Electric-shock hazard
Dangerous voltages and currents are present. Contact with energized equipment will
cause an electric shock that may result in personal injury or death.
Exercise care and follow safe work practices when measuring power external to the
cabinet.

....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the RF connectors

....................................................................................................................................................................................................................................
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.
Important!
The SMA tightening torque must be 0.8 N.m to 1.2 N.m.
The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
The N tightening torque must be 1.7 N.m (1.6 N.m to 1.8 N.m).
Important! Do not forget to ask the site manager for the Node B key.
Important! Notify the OMC administrator in case of service outage or reduction.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Lock the ddm and mcpa objects at the OMC by Set Administrative State. For more
information, refer to Alcatel-Lucent 9353 Wireless Management System - User Guide,
NN-20500-032
...................................................................................................................................................................................................

3 Check for corrosion or oxidation around connectors, nicks and abraded sheaths.
Note: This is more prevalent in high heat and high humidity environments.
...................................................................................................................................................................................................

4 Inspect the bulkhead connectors:


The RF connectors from the bulkhead and tighten them with 7/16 torque wrench.
The PCM connector from the bulkhead and tighten it with screwdriver, if necessary.
The Alarm connector from the bulkhead and tighten it with screwdriver, if necessary.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-7
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the RF connectors

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Inspect the DDM shelf connectors:


The six Rx1 connectors from the three DDMs and tighten them with the SMA torque
wrench.
The six Rx2 connectors from the three DDMs and tighten them with the SMA torque
wrench.
The Antenna Main connectors from the three DDMs and tighten them with the 7/16
torque wrench.
The Antenna Diversity connectors from the three DDMs and tighten them with the
7/16 torque wrench.
The Power/Data connectors from the three DDMs and tighten them with the
screwdriver.
The Transmitter connectors from the three DDMs and tighten them with the N torque
wrench.
...................................................................................................................................................................................................

6 Inspect the Interconnection module connectors:


The DDM connectors (DDM1, DDM2, and DDM3) from the Interconnection module
and tighten them with a screwdriver.
The TRM1 connector from the Interconnection module and tighten it with a
screwdriver.
The PA/PWR connectors (PA1/PWR, PA3/PWR, and PA5/PWR) from the
Interconnection module and tighten them with a screwdriver.
The PA/CTRL connectors (PA1/CTRL, PA3/CTRL, and PA5/CTRL) from the
Interconnection module and tighten them with a screwdriver.
The Alarm connector from the Interconnection module and tighten it with a
screwdriver.
...................................................................................................................................................................................................

7 Inspect the MCPA shelf connectors:


The Power IN data connectors from the three MCPA modules and tighten them with a
screwdriver.
The Data I/O data connectors from the three MCPA modules and tighten them with a
screwdriver.
The Transmitter connectors from the three MCPA modules and tighten them with the
N torque wrench.
The RF IN connectors from the three MCPA modules and tighten them with the SMA
torque wrench.

....................................................................................................................................................................................................................................
8-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the RF connectors

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

8 Inspect the digital shelf connectors:


The Tx out RF connectors from the first TRM and tighten them with the SMA torque
wrench.
The ICO data connector from the first TRM and tighten it with a screwdriver, if
necessary.
The Rx In plug from the first TRM and check that it is pushed in.
The Tx out RF connectors from the second TRM and tighten them with the SMA
torque wrench.
The ICO data connector from the second TRM and tighten it with a screwdriver, if
necessary.
The Rx In plug from the second TRM and check that it is pushed in.
The E1/T1 data connector from one CCM and tighten it with a screwdriver, if
necessary.
...................................................................................................................................................................................................

9 Inspect the MCA module connectors:


The SIM connector from the MCA module and tighten it with a screwdriver.
The IC1 connector from the MCA module and tighten it with a screwdriver.
The IC2 connector from the MCA module and tighten it with a screwdriver.
...................................................................................................................................................................................................

10 Replace or repair any damaged cables. Call the next level of support.
...................................................................................................................................................................................................

11 Inspect one plastic hood on all RF connectors without connections.


...................................................................................................................................................................................................

12 Unlock the ddm and mcpa objects at the OMC by Set Administrative State. For more
information, refer to Alcatel-Lucent 9353 Wireless Management System - User Guide,
NN-20500-032
...................................................................................................................................................................................................

13 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-9
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the anchor bolts

....................................................................................................................................................................................................................................

Inspecting the anchor bolts


Purpose
Carry out the following procedure to check anchor bolts in the 9311 Macro V2 ID.
Note: To check the anchor bolts, the Indoor Cooling Unit (ICU) must be removed.

Intervention time
20 minutes

Tools required
Wrench
Flat screwdriver

NOTICE
Service-disruption hazard
When the cooling unit of an in-service Node B loses power, the air temperature inside the
shelf rises rapidly. When the temperature inside a fabric exceeds 55 degrees Celsius (131
fahrenheit), high temperature fabric alarm 7002 0003 is generated. When the temperature
exceeds 70 degrees Celsius (158 degrees Fahrenheit), alarm 7012 0059 warns that one or
both fabrics will automatically shut down at 72 degrees Celsius (or 161.6 degrees
Fahrenheit) until the temperature drops below 68 degrees Celsius (154.4 degrees
Fahrenheit).
Perform this check rapidly in order to restore normal Node B cooling

procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 <Removing the ICU>


Switch OFF the Cooling Unit breaker
Result: The LEDs are OFF.
...................................................................................................................................................................................................

3 Disconnect the ground cable.


...................................................................................................................................................................................................

4 Disconnect the three connectors at the left.


....................................................................................................................................................................................................................................
8-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the anchor bolts

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Loosen the four ICU screws.


...................................................................................................................................................................................................

6 Remove the ICU.


...................................................................................................................................................................................................

7 Inspect the anchor bolts at the base of the cabinet for tightness and/or damage.
...................................................................................................................................................................................................

8 Tighten the bolts, if necessary.


...................................................................................................................................................................................................

9 <Reinserting the ICU>


Reinsert the ICU.
...................................................................................................................................................................................................

10 Tighten the four ICU screws.


...................................................................................................................................................................................................

11 Reconnect the three connectors at the left.


...................................................................................................................................................................................................

12 Reconnect the ground cable.


...................................................................................................................................................................................................

13 Switch ON the Cooling Unit breaker.


Result: The LEDs are lit
...................................................................................................................................................................................................

14 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary 8-11
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 ID preventive maintenance procedures Inspecting the anchor bolts

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
8-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Appendix A: Product
conformance statements

Overview
Purpose
This appendix provides the 9311 Macro V2 ID product conformance statements.

Contents

European regulatory requirement compliance A-2


North American regulatory requirements compliance A-4
Compliances for other regions/countries A-8
Operational conditions A-9
Cable specifications A-10
Product labelling A-11

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements European regulatory requirement compliance

....................................................................................................................................................................................................................................

European regulatory requirement compliance


Overview
As a radio product, the Node B falls under the requirement of the Radio and Telecom
Terminal Equipment (RTTE) European directive 1999/5/EEC. The RTTE directive covers
essential requirements in the field of:
Protection of the Health and Safety of the user and any other person, including the
objectives with respect to safety requirements contained in the Low Voltage directive
(2006/95/EC)
The protection requirements with respect to EMC contained in Directive
2004/108/EC.
The equipment generates, uses, and can radiate radio frequency energy. If not installed
and used in accordance with the instruction manual, the equipment may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference.
The EMC requirements have been selected to ensure an adequate level of
compatibility for apparatus at residential, commercial, and light industrial
environments. The levels however, do not cover extreme cases which may occur in
any location but with a low probability of occurrence. In particular, it may not cover
those cases where a potential source of interference which is producing individually
repeated transient phenomena, or continuous phenomena, is permanently present, for
example a radar or broadcast site in the near vicinity. In such a case it may be
necessary to either limit the source of interference, or use special protection applied,
to the interfered part, or both.
Note: For operation or maintenance inside Alcatel-Lucent systems, the antistatic wrist
shall always be used to maintain the integrity of the product.
Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources so as to avoid harmful interference. The routes and standards
used to demonstrate compliance with there essential requirements are outlined in the
following paragraphs.
Node B EMC
Compliance with the essential requirements of EMC has been demonstrated using
EN301489-1 & -23 standard.
Node B radio compliance
Compliance with the essential requirements of effective use of the radio spectrum
has been demonstrated using EN301908-1 & -3 standard.
Node B safety
Compliance with the essential requirements of Safety has been demonstrated
using EN 60950-01 standard.
Node B health protection
....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Product conformance statements European regulatory requirement compliance

....................................................................................................................................................................................................................................
Compliance with the essential requirement of health requirement has been
demonstrated using EN50385.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-3
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................

North American regulatory requirements compliance


Overview
The 9311 Macro V2 ID has been qualified according to North American market
requirements.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
Consult the dealer or an experienced radio/TV technician for help

Node B safety
The 9311 Macro V2 ID complies with UL60950-1 and CAN/CSA C22.2 No. 60950-01
Safety Standards. The CSA mark is applied on the Node B and demonstrates compliance
with both US and Canadian Standards.

Node B EMC and radio compliance


The 9311 Macro V2 ID equipped with 850 MHz band radio modules complies with
47CFR Part 15 class B and 47 CFR Part 22 for EMC and radio emission limits according
to US regulatory requirements as indicated on the regulatory label.
The 9311 Macro V2 ID equipped with 1900 MHz band radio modules complies with
47CFR Part 15 class B and 47 CFR Part 24 for EMC and radio emission limits according
to US regulatory requirements as indicated on the regulatory label.

Node B interconnection compliance


The 9311 Macro V2 ID complies with 47 CFR Part 68 of the FCC rules and the
requirements adopted by the ACTA.

....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................
On the top right of this equipment is a label that contains, among other information, a
product identifier in the following format:
US : U3EXDNANUMTSIND for the9311 Macro V2 ID equipped with iCCM2 or
xCCM
US : AB6XDNANUMTSIND for the 9311 Macro V2 ID equipped with CCM or iCCM
If requested, the following information must be provided to the telephone company:
ACTA Registered Number: U3E, AB6
Facility Interface Code (FIC): 04DU9.BN, 04DU9.DN, 04DU9.1KN, and
04DU9.1SN
Service Order Code (SOC): 6.0F
A FCC part 68 and ACTA compliant cable is provided with the Node B equipment, with
no connector at network interface side. The Node B equipment operates with a 1.544
Mbps digital channel. See Installation Instructions for details.
If the Node B equipment causes harm to the phone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required. But if
advance notice is not practical, the telephone company will notify the customer as soon as
possible. Also, you will be advised of your right to file a complaint with the FCC if you
believe it is necessary
The telephone company may make changes to its facilities, equipment, operations or
procedures that could affect the operation of the equipment. If this happens the telephone
company will provide advance notice so you can make the necessary modifications to
maintain uninterrupted services.
If trouble is experienced with this equipment, for repair or warranty information, please
contact:
Hernan R. Noguchi Global
Product Compliance Laboratory (GPCL)
Alcatel-Lucent
Phone: 1-732-332-6002 101
Crawfords Corner Road Building
11C, Room 165 Holmdel NJ 07733-3030
If the equipment is causing harm to the telephone network, the telephone company may
request that you disconnect the equipment until the problem is resolved.
All repairs should be handled by authorized Alcatel-Lucent Service Personnel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-5
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................
Node B data equipment
The following table shows which jacks are associated with which modes of operation.

Operation Mode USOC Jack


Programmable & Test RJ45S

Node B systems
Facility Interface Codes (FIC), Services Order Codes (SOC), USOC Jack Codes, and
Ringer Equivalence Number (REN) are shown in the table below for each port where
applicable.
For the 9311 Macro V2 ID equipped with CCM or iCCM:

Port FIC SOC USOC Jack REN


CCM T1 board 04DU9.BN 6.0F N/A N/A
CCM T1 board 04DU9.DN 6.0F N/A N/A
CCM T1 board 04DU9.1KN 6.0F N/A N/A
CCM T1 board 04DU9.1SN 6.0F N/A N/A
iCCM T1 board 04DU9.BN 6.0F N/A N/A
iCCM T1 board 04DU9.DN 6.0F N/A N/A
iCCM T1 board 04DU9.1KN 6.0F N/A N/A
iCCM T1 board 04DU9.1SN 6.0F N/A N/A

For the 9311 Macro V2 ID equipped with iCCM2 or xCCM:

Port FIC SOC USOC Jack REN


iCCM2 T1 04DU9.BN 6.0F N/A N/A
board
iCCM2 T1 04DU9.DN 6.0F N/A N/A
board
iCCM2 T1 04DU9.1KN 6.0F N/A N/A
board
iCCM2 T1 04DU9.1SN 6.0F N/A N/A
board
xCCM T1 04DU9.BN 6.0F N/A N/A
board1

....................................................................................................................................................................................................................................
A-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................

Port FIC SOC USOC Jack REN


xCCM T1 04DU9.DN 6.0F N/A N/A
board1
xCCM T1 04DU9.1KN 6.0F N/A N/A
board1
xCCM T1 04DU9.1SN 6.0F N/A N/A
board1

Notes:
1. equipped with MDA 4E1/T1 PCM links

Node B RF health protection


Compliance with the North American requirements is demonstrated through calculation
according to FCC OET bulletin 65.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-7
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Compliances for other regions/countries

....................................................................................................................................................................................................................................

Compliances for other regions/countries


Overview
For countries outside Europe and the Americas, the requirements of European countries
usually apply.
UMTS 900 MHz is compliant with China RoHS.
It is not possible to list all the applicable approvals/compliances as they will be dependent
on the markets and products considered.
Note: Please contact your local Alcatel-Lucent representative for more information.

....................................................................................................................................................................................................................................
A-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Product conformance statements Operational conditions

....................................................................................................................................................................................................................................

Operational conditions
Overview
The aforementioned standards compliance of the products are based on the following
operating conditions (called normal operation):
Doors shall be closed and/or covers shall be in place
External cables shall be of the same type as specified by Alcatel-Lucent
No modification of any mechanical or electrical characteristics of the product shall be
made
Any change or modification made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from subsequent responsibility regarding the
standards compliance.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-9
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Cable specifications

....................................................................................................................................................................................................................................

Cable specifications
Overview
The compliance to the aforementioned standards has been verified using cables as
specified by Alcatel-Lucent. The continuing compliance of the product relies upon use of
the correct cabling scheme as well as use of identical type cables as specified by
Alcatel-Lucent. Refer to the installation guides for details on cable specifications.

....................................................................................................................................................................................................................................
A-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Product conformance statements Product labelling

....................................................................................................................................................................................................................................

Product labelling
Overview
The label may be located inside or outside the product, provided that the operation and/or
maintenance personnel have the information when working on the product.

Node B labelling for American Countries


To indicate compliance with the CSA and UL Safety requirements, the 9311 Macro V2 ID
bears the following mark in a conspicuous location.

On the regulatory label, compliance to 47 CFR Part 15, 22 or 24, and 68 is stated along
with:
FCC ID, FCC Registration Number
Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current.

Node B labelling for European Countries


To indicate compliance with the European RTTE Directive, the Node B bears the
following information in a conspicuous location:

Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary A-11
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Product labelling

....................................................................................................................................................................................................................................
Labelling for other regions/countries
Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.

....................................................................................................................................................................................................................................
A-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 ID
Use pursuant to applicable agreements NN-20500-008 UA08.1
Issue 09.07 January 2013
Index

D documentation roadmap, 1-2

................................................................................................

R roadmap

documentation, 1-2
................................................................................................

S Safety statements, 2-1, 2-2

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 ID Alcatel-Lucent Proprietary IN-1
NN-20500-008 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Index

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................