HYDRAULIC VALVES

VALVOLE
OLEOIDRAULICHE

WWW.HBS.IT
HYDRAULIC VALVES
VALVOLE OLEOIDRAULICHE

CATALOGO GENERALE

GENERAL CATALOGUE
HBS Oleoidraulica Hydraulic valves

The
company

Since 1967 HBS Group operates in the With its technical staff HBS is able to
production and marketing of hydraulic realize and customize, in synergy with
and electromechanical components. The the customer, highly innovative hydraulic
constant search for technical solutions, valves and components for each type of
the constant improving the quality of use, from transport to construction, from
product and process, in addition to the construction machinery to agriculture,
efficiency and flexibility of the production from ecology to industrial systems.
allow HBS to the continued success
in the global market. The presence of
PHILOSOPHY R&D
HBS with unit production and trade in
different continents, alongside a qualified
distribution network, provides customer HBS is able to anticipate
HBS bases its development assistance it needs. the needs of the changing
on the singergy with HBS is your partner for the development
and supply of hydraulic components and market and to develop
the customer
electromechanical. customized products
HBS Oleoidraulica Hydraulic valves

Application
INNOVATION

HBS is one truth in a

fields
position to forerunning
the needs of a market
in constant evolution

HYDRAULIC MOTORS
MOBILE CRANE
EXCAVATOR EQUIPMENT
DRILLING RIGS
AERIAL PLATFORMS
EXCAVATORS
CRANE
BASKETS
HOOK
CONCRETE PUMPS
TELEHANDLER

For this we put to disposition know how guaranteed. With the unit planning,
of our engineers and our technicians HBS in a position to devising, realizing
To choose technology who place side by side the customers in and to personalize, in synergy with
HBS, mean to entrust the planning, in the study and the search the customer, valves and hydraulic
of new solutions. components highly innovated for
themselves to a sure, Thanks to the high level of experience every kind of employment, from the
synonymous partner acquired by its personnel, HBS transports to the earth movement,
of quality in the lift. personalised design and planning, from the building to agriculture, the
and high level professional consulting ecology to the industrial systems.
for the installation of systems are HBS bases the principle of its own
development upon synergism with
the costumer.
Indice
Index
Indice - Index

Valvole limitatrici di pressione


Relief valves

Valvole riduttrici di pressione


Reducing-relieing valves

Valvole di sequenza
Sequence valves

Valvole di blocco semplici pilotate


Single pilot operated check valves

Valvole overcenter semplici - Valvole overcenter doppie


Single overcenter valves - Dual overcenter valves

Valvole di controllo movimento


Motion control valves

Valvole controllo portata con protezione contro la rottura di tubazioni


Flow control valves with protection against hoses breakings

Valvole selettrici
Shuttle valves

Valvole strozzatrici unidirezionali


One way flow restrictor valves

Valvole unidirezionali
Check valves

Regolare di portata 3 vie compensato


Three-way pressure compensated flow regulators

Divisori-riunificatori di flusso
Flow dividers-combiners

Deviatori
Diverters

Giunti rotanti
Revolving connectors

Valvole di fine corsa


End stroke valves

Pulsanti 3 vie - 2 posizioni


Three way, 2 position switches
30
60
Cavit 90
Cavity
HBS Oleoidraulica

01 Valvole limitatrici di pressione - Relief valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A010301.01.00 50 400 3/8"G 01.01.01


A010301.02.00 50 400 3/8"G
A010401.01.00 65 400 1/2"G
A010401.02.00 65 400 1/2"G
A010601.01.00 150 400 3/4"G
A010601.02.00 150 400 3/4"G
A010401.05.00 70 350 1/2"G 01.01.04
A010601.04.00 100 400 3/4"G 01.01.04
B010401.11.00 65 350 1/2"G 01.01.03
B010401.12.00 65 350 1/2"G
B010601.11.00 150 350 3/4"G
B010601.12.00 150 350 3/4"G

A010302.01.00 50 400 3/8"G 01.02.01


A010302.02.00 50 400 3/8"G
A010402.01.00 65 400 1/2"G
A010402.02.00 65 65 1/2"G
A010302.13.00 30 500 3/8"G 01.02.03
A010804.01.00 150 350 1"G 01.02.04
B010402.01.00 30 250 1/2"G 01.02.05
B010402.02.00 30 250 1/2"G
B010404.01.00 30 250 1/2"G 01.02.06
A010802.01.00 200 400 1"G 01,02.08
A010302.11.00 50 400 3/8"G 01.02.02
A010302.12.00 50 400 3/8"G
A010402.11.00 65 400 1/2"G
A010402.12.00 65 400 1/2"G

A013807.01.00 30 500 M20x1.5 01.03.01


A013807.02.00 30 500 M20x1.5
Hydraulic valves

Valvole limitatrici di pressione - Relief valves 01

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A013807.03.00 30 500 M20x1.5 01.03.02


A013807.04.00 30 500 M20x1.5
A013807.07.00 30 500 M20x1.5
A013807.08.00 30 500 M20x1.5
A019307.01.00 3 350 3/4-16 UNF 01.03.05
A019307.02.00 3 350 3/4-16 UNF
C010801.01.00 240 420 1"G 01.03.09
C010601.01.00 120 210 3/4"G 01.03.10
A013807.11.00 80 350 M20x1.5 01.03.03
C019901.01.00 150 350 1-14UNS 01.03.04
C019901.02.00 150 350 1-14UNS
C019902.02.00 200 350 1-14UNS 01.03.07
C019902.04.00 200 350 1-14UNS
C019602.01.00 200 350 1"1/16-12 UN 01.03.08
C019602.02.00 200 350 1"1/16-12 UN

A010401.04.00 90 350 1/2"G 01.01.05

C010203.01.00 60 250 7/8-14 UNF 01.03.06

B016004.03.00 30 250 1/2"G 01.02.09


HBS Oleoidraulica

02 Valvole riduttrici di pressione - Reducing_relieing valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C023701.01.00 10 350 M18X1.5 02.01.01


C023701.02.00 10 350 M18X1.5 02.01.01

04 Valvole di sequenza - Sequence valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A040201.01.00 20 500 1/4"G 04.01.01


A040301.01.00 40 500 3/8"G
A040301.02.00 40 500 3/8"G
A040401.17.00 60 500 1/2"G 04.01.02
A040601.14.00 120 500 3/4"G 04.01.04
A040601.15.00 120 500 3/4"G
A040601.18.00 120 500 3/4"G
B040602.01.00 120 300 3/4"G 04.03.02
A040403.01.00 60 400 1/2"G 04.01.04A
A040603.01.00 120 400 3/4"G

A040251.01.00 20 500 1/4"G 04.02.01


A040251.02.00 20 500 1/4"G
A040351.01.00 40 500 3/8"G
A040351.02.00 40 500 3/8"G
A040351.12.00 40 500 3/8"G 04.02.01A
A040351.15.00 40 500 3/8"G 04.02.01B
A040351.08.00 40 500 3/8"G 04.02.01C
A040351.08.01 40 500 3/8"G
A040451.21.00 60 500 1/2"G-1/2"G 04.02.02
A040651.11.00 120 500 3/4"G-3/4"G
B040352.02.00 40 350 3/8"G 04.03.05
A040252.01.00 30 50 1/4"G 04.03.06
A040451.03.00 80 350 1/2"G 04.02.03
A040451.04.00 80 350 1/2"G
Hydraulic valves

Valvole di sequenza - Sequence valves 04

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B040452.02.00 150 350 1/2"G 04.03.04


B040452.03.00 150 350 1/2"G

A040602.03.00 120 350 3/4"G 04.03.07

B040402.02.00 40 220 1/2"G 04.03.08


B040602.02.00 100 220 3/4"G

C044801.02.00 240 350 M36x2 04.04.01

Valvole di blocco semplici pilotate - Single pilot operated check valves 05

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050203.01.00 20 350 1/4"G 05.01.01


A050203.02.00 20 350 1/4"G
A050203.03.00 20 350 1/4"G
A050303.01.00 40 400 3/8"G 05.01.03
A050403.01.00 60 400 1/2"G
B050302.10.00 40 400 3/8"G 05.01.04
A050302.09.00 40 400 3/8"G 05.04.03
A050305.02.00 40 400 3/8"G 05.04.04
HBS Oleoidraulica

05 Valvole di blocco semplici pilotate - Single pilot operated check valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050301.01.00 40 400 3/8"G 05.01.02


A050401.01.00 60 400 1/2"G

05 Valvole di blocco doppie pilotate - Dual pilot operated check valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050253.01.00 20 350 1/4"G 05.02.01


A050253.02.00 20 350 1/4"G
A050253.03.00 20 350 1/4"G
A050253.10.00 20 350 1/4"G 05.02.03
A050253.11.00 20 350 1/4"G
A050253.12.00 20 350 1/4"G
A050353.03.00 40 400 3/8"G 05.02.03A
A050453.03.00 60 400 1/2"G 05.02.04
A050353.15.00 40 400 3/8"G 05.02.05
B050353.13.00 40 350 3/8"G
B050353.15.00 40 350 3/8"G
B050453.13.00 60 350 1/2"G
A050353.16.00 30 230 TUBO/PIPE 12 05.02.06
A050452.01.00 60 400 1/2"G 05.06.02
A050452.02.00 60 400 1/2"G
B050452.01.00 60 350 1/2"G
B050452.02.00 60 350 1/2"G
B050452.03.00 60 350 1/2"G
A050352.03.00 40 350 3/8"G 05.06.03
B050351.04.00 30 210 3/8"G 05.06.04
B050357.02.00 30 350 3/8"G 05.04.10
Hydraulic valves

Valvole di blocco doppie pilotate - Dual pilot operated check valves 05

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050351.01.00 40 400 3/8"G 05.02.02


A050351.02.00 40 400 3/8"G
A050351.03.00 40 400 3/8"G
A050351.04.00 40 400 3/8"G 05.02.02A
A050351.06.00 40 350 3/8"G
B050351.02.00 30 350 3/8"G
A050451.01.00 60 400 1/2"G 05.02.02F
A050451.05.00 60 350 1/2"G 05.02.02G
A050451.06.00 60 400 1/2"G
A050451.07.00 60 350 1/2"G
A050451.08.00 60 350 1/2"G
A050351.08.00 40 400 3/8"G 05.02.02H
A050351.09.00 40 350 3/8"G
A050352.01.00 40 350 3/8"G 05.06.01
B050352.02.00 40 350 3/8"G
B050352.03.00 40 350 3/8"G
B050352.04.00 40 350 3/8"G
B050352.05.00 40 350 3/8"G
B050352.06.00 40 350 3/8"G

Valvole di blocco semplici pilotate+rubinetto


Single pilot operated check valves+manual shut-off 05

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050304.01.00 40 400 3/8"G 05.03.01


A050404.03.00 60 400 1/2"G
A050304.02.00 40 400 3/8"G 05.03.02
A050404.04.00 60 400 3/8"G
B050304.05.00 40 300 3/8"G 05.03.03
B050304.06.00 40 300 3/8"G 05.03.04
A050302.01.00 40 400 3/8"G 05.04.01
A050302.02.00 40 400 3/8"G 05.04.02
HBS Oleoidraulica

05 Valvole di blocco pilotata a cartuccia - Pilot operated check valves cartridge type

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B050310.01.00 40 400 3/8"G 05.04.05


B050310.02.00 40 400 3/8"G
B050310.03.00 40 400 3/8"G
B050310.04.00 40 400 3/8"G
A053908.01.00 40 350 M22x1.5 05.08.01
C052101.01.00 60 350 M22x1.5 05.08.02
C052201.01.00 120 350 1-14 UNF 05.08.03
C054801.01.00 240 350 M36X2 05.08.04
C059301.01.00 30 350 3/4"-16UNF 05.08.05
C054601.01.00 80 350 M33X2 05.08.06

A059507.51.00 100 400 1-14 UNF 05.07.01

05 Valvola di blocco pilotata a manicotto - Pilot operated check valve sleeve type

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A050611.01.00 100 300 3/4"G 05.09.01


Hydraulic valves

Valvole overcenter semplici - Single overcenter valves 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060300.00.00 45 500 3/8"G 06.01.01


A060300.01.00 45 500 3/8"G
A060300.02.00 45 500 3/8"G
A060400.00.00 60 500 1/2"G 06.01.02
A060400.01.00 60 500 1/2"G
A060261.01.00 20 500 1/4"G 06.01.03
A060261.02.00 20 500 1/4"G
A060261.03.00 20 500 1/4"G
A060361.11.00 45 500 3/8"G
A060361.12.00 45 500 3/8"G
A060361.13.00 45 500 3/8"G
A060461.01.00 60 500 1/2"G
A060461.02.00 60 500 1/2"G
A060461.03.00 60 500 1/2"G
A060261.22.00 30 500 1/4"G 06.01.03A
A060861.01.00 200 350 1"G 06.02.06
A060600.02.00 140 500 3/4"G 06.02.07

A060300.20.00 45 500 3/8"G 06.02.01


A060400.20.00 60 500 1/2"G
B060661.01.00 100 400 3/4"G 06.12.01
B060461.02.00 40 350 1/2"G 06.12.01
A060600.01.00 140 400 3/4"G 06.02.08

A060261.04.00 20 500 1/4"G 06.02.02


A060261.05.00 20 500 1/4"G
A060261.06.00 20 500 1/4"G
A060361.14.00 45 500 3/8"G
A060361.15.00 45 500 3/8"G
A060361.16.00 45 500 3/8"G
A060461.04.00 60 500 1/2"G
A060461.05.00 60 500 1/2"G
A060461.06.00 60 500 1/2"G
HBS Oleoidraulica

06 Valvole overcenter semplici - Single overcenter valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060461.12.00 120 500 1/2"G 06.02.03


A060461.13.00 120 500 1/2"G
A060661.02.00 150 500 3/4"G 06.02.04
A060661.03.00 150 500 3/4"G
A060466.12.00 120 500 1/2"G 06.07.04
A060466.13.00 120 500 1/2"G
A060666.02.00 150 500 3/4"G 06.07.05
A060666.03.00 150 500 3/4"G
A060461.15.00 80 350 1/2"G 06.02.09
A060461.16.00 80 400 1/2"G 06.02.10
A060421.00.00 60 500 1/2"G 06.05.01
A060421.01.00 60 500 1/2"G

06 Ovc semplici con v.max - Single ovc with pressure relief

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060361.07.00 45 500 3/8"G 06.02.02A


A060361.08.00 45 500 3/8"G
A060361.09.00 45 500 3/8"G
Hydraulic valves

Ovc semplici con v. anti rottura tubi - Single ovc with hose brust valve 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060361.04.00 45 500 3/8"G 06.02.02B


A060361.05.00 45 500 3/8"G
A060361.06.00 45 500 3/8"G
A060271.24.00 30 500 1/4"G 06.09.04B
A060281.24.00 30 500 1/4"G 06.09.04C

A060491.05.00 60 500 1/2"G 06.08.04


A060491.08.00 120 500 1/2"G 06.08.04A
A060491.09.00 120 500 1/2"G

Valvole overcenter semplici flangiabili - Flangeable single overcenter valves 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060391.02.00 45 500 3/8"G 06.08.02


A060491.01.00 60 500 1/4"G 06.08.02D
A060491.02.00 60 500 1/4"G
A060491.03.00 60 500 1/4"G
A060491.04.00 60 500 1/4"G
A060491.06.00 120 500 1/2"G 06.08.02E
A060491.07.00 120 500 1/2"G
HBS Oleoidraulica

06 Valvole overcenter semplici flangiabili - Flangeable single overcenter valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B060391.11.00 45 500 3/8"G 06.08.02A


A060271.01.00 20 500 1/4"G 06.09.01
A060271.02.00 20 500 1/4"G
A060271.03.00 20 500 1/4"G
A060371.01.00 45 500 3/8"G
A060371.02.00 45 500 3/8"G
A060371.03.00 45 500 3/8"G
A060471.01.00 60 500 1/2"G
A060471.02.00 60 500 1/2"G
A060471.03.00 60 500 1/2"G
A060471.16.00 60 500 1/2"G
A063691.02.00 45 500 M16x1.5 06.08.02B
A063691.05.00 45 500 M16x1.6

A060393.13.00 60 500 3/8"G 06.08.02C


A060393.14.00 60 500 3/8"G
A060393.15.00 60 500 3/8"G
A060271.12.00 20 500 1/4"G 06.09.04
A060371.12.00 45 500 3/8"G

A060481.14.00 150 500 1/2"G 06.09.01B


A060481.15.00 150 500 1/2"G
Hydraulic valves

Valvole overcenter semplici flangiabili - Flangeable single overcenter valves 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060281.01.00 20 500 1/4"G 06.09.02


A060281.02.00 20 500 1/4"G
A060281.03.00 20 500 1/4"G
A060381.01.00 45 500 3/8"G
A060381.02.00 45 500 3/8"G
A060381.03.00 45 500 3/8"G
A060481.01.00 60 500 1/2"G
A060481.02.00 60 500 1/2"G
A060481.03.00 60 500 1/2"G
A060481.06.00 60 500 1/2"G
A060281.05.00 20 500 1/4"G 06.09.03
A060281.22.00 30 500 1/4"G 06.09.03A
A068255.03.00 350 500 3/4" SAE 6000 06.09.07
A068455.03.00 350 500 1" SAE 6000
A068555.03.00 350 500 1"1/4 SAE 6000

A068255.04.00 350 500 3/4" SAE 6000 06.09.08


A068455.02.00 350 500 1" SAE 6000
A068555.02.00 350 500 1"1/4 SAE 6000

A060471.25.00 60 420 1/2"G 06.09.05A

B060491.03.00 60 350 1/2"G 06.13.23


HBS Oleoidraulica

06 Valvole overcenter semplici flangiabili - Flangeable single overcenter valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060481.08.00 120 400 1/2"G 06.13.20


A060881.01.00 350 400 1"G 06.13.21
B060671.01.00 150 350 3/4"G 06.13.22

B060381.12.00 80 350 3/8"G 06.13.24


B060481.02.00 80 350 1/2"G 06.13.25
A060481.10.00 50 300 1/2"G 06.13.26

A060481.07.00 90 380 1/2"G 06.09.05C

06 Valvole overcenter semplici c.c. - Single overcenter valves c.c.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060676.02.00 150 500 3/4"G 06.02.05


A060676.03.00 150 500 3/4"G
Hydraulic valves

Valvole overcenter semplici c.c. - Single overcenter valves c.c. 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060326.00.00 45 500 3/8"G 06.06.01


A060426.00.00 60 500 1/2"G 06.06.02
A060266.01.00 20 500 1/4"G 06.06.03
A060266.02.00 20 500 1/4"G
A060266.03.00 20 500 1/4"G
A060366.11.00 45 500 3/8"G
A060366.12.00 45 500 3/8"G
A060366.13.00 45 500 3/8"G
A060466.01.00 60 500 1/2"G
A060466.02.00 60 500 1/2"G
A060466.03.00 60 500 1/2"G
A060416.11.00 60 500 1/2"G 06.06.04
A060326.20.00 45 500 3/8"G 06.07.01
A060426.20.00 60 500 1/2"G
A060426.30.00 60 500 1/2"G 06.07.02
A060626.01.00 140 500 3/4"G 06.07.06
A060626.02.00 140 500 3/4"G

A060266.04.00 20 500 1/4"G 06.07.03


A060266.05.00 20 500 1/4"G
A060266.06.00 20 500 1/4"G
A060366.14.00 45 500 3/8"G
A060366.15.00 45 500 3/8"G
A060366.16.00 45 500 3/8"G
A060466.04.00 60 500 1/2"G
A060466.05.00 60 500 1/2"G
A060466.06.00 60 500 1/2"G
A060466.17.00 60 400 1/2"G 06.02.04A
A060666.06.00 100 400 3/4"G
HBS Oleoidraulica

06 Valvole overcenter semplici flangiabili c.c. - Flangeable single overcenter valves c.c.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060496.01.00 120 500 1/2"G 06.08.02F


A060496.02.00 120 500 1/2"G
A060376.10.00 40 500 3/8"G 06.10.01A

A060271.22.00 30 500 1/4"G 06.09.04A


A060686.01.00 150 500 3/4"G 06.10.03

A060471.14.00 120 500 1/2"G 06.09.05


A060471.15.00 120 500 1/2"G
A060476.14.00 120 500 1/2"G 06.10.01C
A060476.15.00 120 500 1/2"G
A060486.14.00 120 500 1/2"G 06.10.02A
A060486.15.00 120 500 1/2"G
Hydraulic valves

Valvole overcenter semplici flangiabili c.c. - Flangeable single overcenter valves c.c. 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060276.01.00 20 500 1/4"G 06.10.01


A060276.02.00 20 500 1/4"G
A060276.03.00 20 500 1/4"G
A060276.04.00 45 500 3/8"G
A060276.05.00 45 500 3/8"G
A060276.06.00 45 500 3/8"G
A060276.07.00 60 500 1/2"G
A060276.08.00 60 500 1/2"G
A060276.09.00 60 500 1/2"G
A060371.08.00 45 500 3/8"G 06.10.01B
A060286.01.00 20 500 1/4"G 06.10.02
A060286.02.00 20 500 1/4"G
A060286.03.00 20 500 1/4"G
A060386.01.00 45 500 3/8"G
A060386.02.00 45 500 3/8"G
A060386.03.00 45 500 3/8"G
A060486.01.00 60 500 1/2"G
A060486.02.00 60 500 1/2"G
A060486.03.00 60 500 1/2"G
A060476.17.00 90 350 1/2"G 06.10.04
B060371.02.00 60 350 3/8"G 06.09.05B

Valvole overcenter semplici flangiabili con anti-shock


Flangeable single overcenter valves with anti-shock 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060471.19.00 80 500 1/2"G 06.09.06


A060491.12.00 80 500 1/2"G 06.09.06A
HBS Oleoidraulica

Valvole overcenter semplici ad area differenziale zero


06 Single overcenter valves with zero differential area

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B060461.01.00 90 350 1/2"G 06.13.01

B060486.01.00 90 350 1/2"G 06.13.02


A060486.05.00 90 350 1/2"G 06.13.03

A060696.01.00 150 420 3/4"G 06.13.04

Valvole overcenter semplici per controllo e blocco discesa


06 Load holding-metering valves for cranes

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A068271.01.00 200 420 3/4"SAE6000 06.15.20


A068271.03.00 200 420 3/4"SAE6000 06.15.22

A068271.02.00 200 420 3/4"SAE6000 06.15.21


Hydraulic valves

Overcenter semplici in linea per escavatori


Single overcenter valve for earth moving machines 06

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A060350.01.00 40 500 3/8"G 06.14.01


A060350.02.00 40 500 3/8"G 06.14.02
A060450.01.00 100 500 1/2"G 06.14.03
A060450.02.00 100 500 1/2"G 06.14.04
A060650.01.00 150 500 3/4"G 06.14.05
A060650.02.00 150 500 3/4"G 06.14.06

A068155.01.00 120 500 1/2" SAE 6000 06.15.01


A068155.02.00 120 500 1/2" SAE 6000 06.15.02

A068255.01.00 250 500 3/4" SAE 6000 06.15.03


A068255.02.00 350 500 3/4" SAE 6000 06.15.04
A068355.01.00 250 500 3/4" SAE 3000 06.15.05
A068455.01.00 400 500 1" SAE 6000 06.15.06
A068555.01.00 500 500 1" 1/4 SAE 6000 06.15.07
HBS Oleoidraulica

06 Valvole overcenter semplici a cartuccia - Single overcenter valves cartridge type

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C069601.01.00 60 400 1 1/16-12 06.16.01


C060801.01.00 120 350 1 1/16-12 06.16.05
C060801.03.00 120 350 1 1/16-12 06.16.05
C065901.01.00 100 350 M27X1.5 06.16.06
C064601.02.00 140 350 M33X2 06.16.07
C060401.02.00 30 350 1/2"G 06.16.09

C069501.01.00 90 350 1 3/16-12 06.16.02


C064601.01.00 150 350 M33x2 06.16.03
C065201.01.00 300 350 M42X2 06.16.10

C064603.01.00 140 350 M33x2 06.16.08


Hydraulic valves

Valvole overcenter doppie - Dual overcenter valves 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070261.22.00 30 500 1/4"G 07.01.01


A070361.01.00 45 500 3/8"G 07.01.03
A070361.02.00 45 500 3/8"G
A070361.03.00 45 500 3/8"G
A070461.01.00 60 500 1/2"G
A070461.02.00 60 500 1/2"G
A070461.03.00 60 500 1/2"G
B070461.04.00 60 350 1/2"G 07.01.03B
B070461.05.00 60 350 1/2"G
B070461.06.00 60 350 1/2"G
A070300.11.00 45 500 3/8"G 07.01.04
A070300.12.00 45 500 3/8"G
B070300.11.00 45 350 3/8"G
B070300.12.00 45 350 3/8"G
A070400.11.00 80 500 1/2"G 07.01.05
A070400.12.00 80 500 1/2"G
A070600.11.00 140 500 3/4"G 07.01.07A
A070600.12.00 140 500 3/4"G
B070600.11.00 140 350 3/4"G
B070600.12.00 140 350 3/4"G
B070600.01.00 120 350 3/4"G 07.01.07B
A070800.01.00 200 350 1"G 07.01.07D
A070281.24.00 20 450 1/4"G 07.03.02C
B070461.09.00 150 380 1/2"G 07.01.07C

A070361.55.00 30 500 3/8"G 07.11.00


HBS Oleoidraulica

07 Valvole overcenter doppie - Dual overcenter valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070461.59.00 60 450 1/2"G 07.06.02

A070461.57.00 70 400 1/2"G 07.06.03

07 Valvole overcenter doppie flangiabili - Flangeable dual overcenter valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B070416.01.00 80 350 1/2"G 07.01.05A


B070416.02.00 80 350 1/2"G
B070416.03.00 80 350 1/2"G
A070316.01.00 45 350 3/8"G 07.01.05B
A070316.02.00 45 350 3/8"G
B076016.01.00 40 350 FLANG. 07.01.05C
A070381.01.00 45 500 3/8"G 07.03.02
A070381.02.00 45 500 3/8"G
A070381.03.00 45 500 3/8"G
A070481.01.00 60 500 1/2"G
A070481.02.00 60 500 1/2"G
A070481.03.00 60 500 1/2"G
A070281.22.00 30 500 1/4"G 07.03.02A
Hydraulic valves

Valvole overcenter doppie flangiabili - Flangeable dual overcenter valves 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B076016.01.00 90 500 1/2"G 07.01.05D

A070371.01.00 45 500 3/8"G 07.03.01


A070371.02.00 45 500 3/8"G
A070371.03.00 45 500 3/8"G
A070471.01.00 60 500 1/2"G
A070471.02.00 60 500 1/2"G
A070471.03.00 60 500 1/2"G

A070271.22.00 30 500 1/4"G 07.03.01A

A072381.01.00 45 350 ISO CETOP 3 07.03.02B


A072381.02.00 45 350 ISO CETOP 3
A072381.03.00 45 350 ISO CETOP 3

A070681.01.00 150 500 3/4"G 07.08.01


A070681.02.00 150 500 3/4"G

B070281.06.00 30 500 1/4"G 07.03.02D


HBS Oleoidraulica

07 Valvole overcenter doppie c.c. - Dual overcenter valves c.c.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070366.01.00 45 500 3/8"G 07.02.03


A070366.02.00 45 500 3/8"G
A070366.03.00 45 500 3/8"G
A070466.01.00 60 500 1/2"G
A070466.02.00 60 500 1/2"G
A070466.03.00 60 500 1/2"G
A070306.11.00 45 500 3/8"G 07.02.04
A070306.12.00 45 500 3/8"G
A070306.13.00 45 500 3/8"G
A070406.11.00 80 500 1/2"G 07.02.05
A070406.12.00 80 500 1/2"G
A073906.11.00 80 500 M22x1.5
A073906.12.00 80 500 M22x1.5
B070461.08.00 60 350 1/2"G 07.02.06
A070606.11.00 140 500 3/4"G 07.02.07A
A070606.12.00 140 500 3/4"G
B070661.01.00 140 350 3/4"G 07.02.07B
A070606.13.00 140 400 3/4"G 07.06.04

07 Valvole overcenter doppie flangiabili c.c. - Flangeable dual overcenter valves c.c.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070376.01.00 45 500 3/8"G 07.04.01


A070376.02.00 45 500 3/8"G
A070376.03.00 45 500 3/8"G
A070476.01.00 60 500 1/2"G
A070476.02.00 60 500 1/2"G
A070476.03.00 60 500 1/2"G
Hydraulic valves

Valvole overcenter doppie flangiabili c.c. - Flangeable dual overcenter valves c.c. 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070386.01.00 45 500 3/8"G 07.04.02


A070386.02.00 45 500 3/8"G
A070386.03.00 45 500 3/8"G
A070486.01.00 60 500 1/2"G
A070486.02.00 60 500 1/2"G
A070486.03.00 60 500 1/2"G

A070686.01.00 150 500 3/4"G 07.09.01


A070686.02.00 150 500 3/4"G

B070466.01.00 150 350 1/2"G 07.02.07C

Valvole overcenter doppie+reg. di flusso - Dual overcenter valves+flow reg. 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070311.00.00 40 500 3/8"G 07.05.01


A070411.01.00 60 500 1/2"G 07.05.02
HBS Oleoidraulica

07 Valvole overcenter doppie+reg. di flusso - Dual overcenter valves+flow reg.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070311.03.00 45 500 3/8"G 07.05.03

A070351.01.00 45 350 3/8"G 07.05.04

B070361.15.00 45 350 3/8"G 07.05.05

Valvole overcenter doppie per motori idraulici


07 Dual overcenter valves for hydraulic motors

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070361.51.00 45 500 3/8"G 07.06.01


A070361.52.00 45 500 3/8"G
A070461.51.00 60 500 1/2"G
A070461.52.00 60 500 1/2"G
C1 F C2

A B
Hydraulic valves

Valvole overcenter doppie per motori idraulici


Dual overcenter valves for hydraulic motors 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070461.22.00 80 500 1/2"G 07.11.01

F2 V2

F1 V1

Valvole overcenter doppie flangiabili per motori idraulici


Flangeable dual overcenter valves for hydraulic motors

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C3 B070381.22.00 40 350 3/8"G 07.12.01


B070481.26.00 60 350 1/2"G 07.13.03
1
V2 C2 B070481.30.00 60 350 1/2"G 07.13.06
4
3

V1 C1
2

B070481.22.00 60 350 1/2"G 07.13.01


C3
B070481.25.00 60 350 1/2"G 07.13.02
B070481.27.00 60 350 1/2"G 07.13.04
V2 C2 B070481.28.00 60 350 1/2"G 07.13.05
B070481.35.00 60 350 1/2"G 07.13.09
B070481.38.00 60 350 1/2"G 07.13.10
V1 C1
A070481.41.00 40 350 1/2"G 07.13.11
B070481.31.00 80 350 1/2"G 07.13.12
B070381.26.00 55 350 3/8"G 07.13.13
B070481.50.00 60 350 1/2"G 07.13.14
B070481.43.00 60 210 1/2"G 07.13.15

C1 C2

M1 M2

V1 C3 V2
HBS Oleoidraulica

Valvole overcenter doppie flangiabili per motori idraulici


07 Flangeable dual overcenter valves for hydraulic motors

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C3 B070481.32.00 60 350 1/2"G 07.13.07

V2 C2

V1 C1

C3 B070481.33.00 60 350 1/2"G 07.13.08

1
V2 C2

4
3

V1 C1
2

A078481.06.00 300 350 1"SAE6000 07.16.02


A078581.03.00 300 350 1-1/4"SAE6000 07.16.02
C1 C2
A078281.01.00 120 350 3/4"SAE6000 07.16.03
M1 12 M2
A078481.01.00 300 350 1"SAE6000 07.16.03
A078481.05.00 300 350 1"SAE6000 07.16.03
A078581.01.00 300 350 1-1/4"SAE6000 07.16.03
Dr Dr
3 A078581.02.00 300 350 1-1/4"SAE6000 07.16.03
C3 C3
A078281.02.00 150 420 3/4"SAE6000 07.16.01
V1 V2
A078281.03.00 150 420 3/4"SAE6000 07.16.01
A078481.07.00 300 400 1"SAE6000 07.16.01

Valvole overcenter doppie ad area differenziale zero


07 Dual overcenter valves with zero differential area

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B070461.07.00 90 400 1/2"G 07.10.01


B070481.34.00 150 400 1/2"G 07.10.02
B1 A1
M

2 4
3
1

T B A
Hydraulic valves

Valvole overcenter doppie per circ. rigenerativi


Dual overcenter valves for regenerative circ. 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A070360.02.00 40 450 3/8"G 07.07.01


C2 C1

4 2

1 3

V2 V1

B070460.01.00 60 350 1/2"G 07.07.02


C2 C1

V2 V1

B070660.01.00 100 350 3/4"G 07.15.01


C2 C1

M
)(

V2 V1

B1 A1
B070660.02.00 100 350 3/4"G 07.07.03
2 5

6 1
3

B A

B070390.01.00 45 350 3/8"G 07.07.04

C1 C2

Valve 1

Valve 2

T V1 V2
HBS Oleoidraulica

Valvole overcenter doppie per circ. rigenerativi


07 Dual overcenter valves for regenerative circ.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B070660.07.00 150 350 3/4"G 07.07.05


C2 C1

Vu4 Ovc2

Vu5
Ev3
Ev2 Ovc1 Str
Vu7

0.5
1.2

V2 V1

B070460.05.00 100 350 1/2"G 07.07.06

C2 C1
valve 1

valve 2

V2 V1

Valvole overcenter doppie flangiabili per circ. rigenerativi


07 Flangeable dual overcenter valves for regenerative circ.

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A078290.01.00 220 420 3/4" SAE 6000 07.15.02

C2 C1

2
3

V2 V1

A078590.01.00 400 420 1"1/4 SAE 6000 07.15.03


C2 C1

1 4
5

V2 V1

C3 C2 C1 B070690.03.00 120 350 3/4"SAE3000 07.15.04

Vu2 2

3 Vu1
optional
EV Vu3
1

V2 V1
Hydraulic valves

Valvole overcenter doppie flangiabili per circ. rigenerativi


Flangeable dual overcenter valves for regenerative circ. 07

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B070660.04.00 180 350 3/4"G 07.15.05


A1 B1

Vu1 2

Vu2
optional
Ev2
Ev1 1 Str
Vu3

1.2 0.5

A B

Valvole di controllo movimento - Motion control valves 08

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B080401.01.00 70 350 1/2"G 08.01.01

C1 C2

1 2

V1 V2

B080404.01.00 100 350 1/2"G 08.01.02

C1 C2

1 2
34

C3

V1 V2

A080402.03.00 80 500 1/2"G 08.02.03


C2 C1
3 4

2 1

6 5

V2 V1
HBS Oleoidraulica

08 Valvole di controllo movimento - Motion control valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A080402.06.00 80 700 1/2"G 08.02.04

C2 C1
3 4
2 1

V2 V1

A080602.01.00 120 350 3/4"G 08.03.01

C1 C2

1 2

3 4

C3

V1 V2

B080804.01.00 200 350 1"G 08.03.01A


C1 C2

12

V1 C3 V2

A080402.12.00 80 350 1/2"G 08.03.02

C2 C1

2 1

V2 V1
Hydraulic valves

Valvole controllo portata con protezione contro la rottura di tubazioni


Flow control valves with protection against hoses breakings 09

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A090201.01.00 25 350 1/4"G 09.01.01


A090301.01.00 50 350 3/8"G
A090401.01.00 80 350 1/2"G
A090601.01.00 150 350 3/4"G
A090251.01.00 25 350 1/4"G 09.02.01
D C
A090351.01.00 50 350 3/8"G
A090451.01.00 80 350 1/2"G
A090651.01.00 150 350 3/4"G

Valvole selettrici - Shuttle valves 10

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A100202.02.00 20 700 1/4"G 10.01.01


C A100302.01.00 45 700 3/8"G
A100402.01.00 60 700 1/2"G
A600302.13.00 20 500 3/4-16 UNF 10.01.02
C100200.01.00 40 350 1/4"G 10.01.03
B A
C100100.01.00 10 350 1/8"G

Valvole strozzatrici unidirezionali - One way flow restrictor valve 11

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A110200.01.00 20 350 1/4"G 11.01.01


A110300.01.00 40 350 3/8"G
A110300.02.00 40 350 3/8"G
B A
A110400.01.00 60 350 1/2"G
A110400.02.00 60 350 1/2"G
A110600.01.00 120 350 3/4"G 11.01.02
A110800.01.00 240 350 1"G
A110200.10.00 3 350 1/4"G 11.03.01
A110400.11.00 70 350 1/2"G 11.05.04
HBS Oleoidraulica

11 Valvole strozzatrici unidirezionali - One way flow restrictor valve

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A110200.11.00 10 350 1/4"G 11.04.01


A110200.12.00 10 350 1/4"G
A110200.13.00 10 350 1/4"G
A110200.14.00 10 350 1/4"G
A110200.15.00 10 350 1/4"G
A110200.16.00 10 350 1/4"G
A B A110200.17.00 10 350 1/4"G
A110200.18.00 10 350 1/4"G

11 Valvole strozzatrici bidirezionali - Bidirectional flow restrictor valve

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A110210.01.00 20 350 1/4"G 11.02.01


A110310.01.00 40 350 3/8"G
A110410.01.00 60 350 1/2"G
A110610.01.00 120 350 3/4"G 11.02.02
A110810.01.00 240 350 1"G

B A
Hydraulic valves

valvole unidirezionali - Check valves 12

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A120200.01.00 15 700 1/4"G 12.01.01


A120200.02.00 15 700 1/4"G
A120200.03.00 15 700 1/4"G
A120300.01.00 35 700 3/8"G
A120300.02.00 35 700 3/8"G
A120300.03.00 35 700 3/8"G
A120400.01.00 50 700 1/2"G
A120400.02.00 50 700 1/2"G
A120400.03.00 50 700 1/2"G
B A
A120600.01.00 90 700 3/4"G 12.01.02
A120600.02.00 90 700 3/4"G
A120600.03.00 90 700 3/4"G
A120800.01.00 150 700 1"G
A120800.02.00 150 700 1"G
A120800.03.00 150 700 1"G
A120410.01.00 60 350 1/2"G 12.02.01
A120610.01.00 130 350 3/4"G
A120810.01.00 250 350 1"G
A121010.01.00 350 350 1"1/4G

Valvole unidirezionali a cartuccia - Check valves cartridge type 12

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C123900.01.00 65 350 M22x1.5 12.03.01


C120600.01.00 65 350 3/4"G 12.03.02
C129700.01.00 150 400 1-5/16-12UN 12.03.03

B A
HBS Oleoidraulica

Regolatore di portata 3 vie compensato


13 Three-way pressure compensated flow regulators

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A130301.01.00 30 230 3/8"G 13.01.01


A130401.01.00 55 230 1/2"G
A130601.01.00 150 230 3/4"G 13.01.02
E R
B130801.01.00 280 230 1"G 13.01.03

Regolatore di portata 3 vie compensato con valvola di massima pressione


13 Three-way pressure compensated flow regulators with relief valve

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B130405.01.00 90 350 1/2"G 13.02.01


B130805.01.00 280 350 1"G 13.02.02
E R

Regolatore di portata 3 vie compensato per due utilizzi


13 Three-way combination type pressure compensated flow regulator

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B130302.01.00 55 230 3/8"G 13.03.01


B130402.01.00 90 230 1/2"G
B130602.01.00 150 230 3/4"G 13.03.02
E P B130802.01.00 380 230 1"G

B
Hydraulic valves

Regolatore di portata a 3 vie compensato con elettrocomando e limitatrice di pressione


Pressure compensated flow regulator, 3 ways, with solenoid control and relief valve 13

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A130403.01.00 100 350 1/2"G 13.04.01


A130403.02.00 100 350 1/2"G
A130603.01.00 200 350 3/4"G 13.04.02
A130603.02.00 200 350 3/4"G
A130803.01.00 220 350 1"G 13.04.03
OPZIONALE/OPTIONAL A130803.02.00 220 350 1"G

42
A131003.01.00 400 350 1"1/4 G 13.04.04
B A
A131003.02.00 400 350 1"1/4 G

3 1

P T

Regolatore di portata a cartuccia - Cartridge flow regulator 13

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

C133900.01.00 45 210 M22x1.5 13.05.01

E P

B
HBS Oleoidraulica

14 Divisori/riunificatori di flusso - Flow dividers/combiners

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A140300.21.00 6 400 3/8"G 14.01.01


A140300.22.00 10 400 3/8"G
A140300.23.00 20 400 3/8"G
A140300.24.00 32 400 3/8"G
A140300.25.00 40 400 3/8"G
C1 C2
A140300.26.00 60 400 3/8"G
A140400.01.00 95 250 1/2"G-3/4"G 14.01.03
C141701.01.00 7 210 7/8-14 UNF 14.02.01
C141701.02.00 15 210 7/8-14 UNF
C141701.03.00 22 210 7/8-14 UNF
C141701.04.00 30 210 7/8-14 UNF
A
C141701.05.00 38 210 7/8-14 UNF
C141701.06.00 45 210 7/8-14 UNF
C143800.01.00 12 350 M20x1.5 14.02.02
C149600.01.00 60 240 1-1/16-12UN 14.02.03
C149600.02.00 90 240 1-1/16-12UN
A140300.31.00 6 400 3/8"G 14.01.02
A140300.32.00 10 400 3/8"G
A140300.33.00 20 400 3/8"G
A140300.34.00 32 400 3/8"G
C1 C2
A140300.35.00 40 400 3/8"G

C3 C4

X1 X2

A B

A140600.01.00 150 400 3/4"G 14.01.04


A140600.02.00 95 400 3/4"G

C1 C2
0.5

V
Hydraulic valves

Deviatori - Diverters 15

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A150201.01.00 40 700 1/4"G 15.01.01


A150401.03.00 70 700 1/2"G
A B C D

A150202.01.00 40 700 1/4"G 15.02.01

A B C D E F G H

A150212.01.00 30 700 1/4"G 15.02.02

5 6 7 8

12 3 4

Deviatori a 3 vie - 3 way diverters 15

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A150303.01.00 40 500 3/8"G 15.03.01


A150403.01.00 60 500 1/2"G
A150603.01.00 100 500 3/4"G
A150803.01.00 180 500 1"G
A B
A150603.04.00 100 500 3/4"G 15.03.02
A150803.02.00 180 500 1"G

P
HBS Oleoidraulica

15 Deviatori a 4 vie - 4 way diverters

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A150404.01.00 300 400 1/2"G 15.04.01


A150604.01.00 120 400 3/4"G 15.05.01
A150604.04.00 120 400 3/4"G
A
P

A600050.22.00 120 400 1/2"G 15.05.02

M1
3
P A

2
T

M2
1
M

15 Deviatori a 6 vie - 6 way diverters

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A150406.01.00 60 400 1/2"G 15.01.01A

A1 B1 A2 B2

P1 P2
A B
Hydraulic valves

Deviatori multifunzione - Multifunction diverter 15

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A150307.51.00 45 200 3/8"G 15.06.01


A150307.52.00 45 200 3/8"G
R

A B C D

P S

A150308.51.00 45 300 3/8"G 15.06.02


A150308.52.00 45 300 3/8"G
R
A150308.54.00 45 300 3/8"G
A BC D E F G H

P S

Giunti rotanti - Revolving connectors 17

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A170302.01.00 45 350 3/8"G 17.01.01


A170402.01.00 60 350 1/2"G
A170602.01.00 120 350 3/4"G
A173703.01.00 40 350 M18x1.5 17.02.01
A174003.01.00 60 350 M24x1.5 17.03.01
A174403.01.00 100 350 M30x2
A174803.01.00 150 100 M36x2
A170302.51.00 45 350 3/8"G 17.04.01
A170402.51.00 60 350 1/2"G
A170602.51.00 120 350 3/4"G
A173703.51.00 60 350 M18x1.5 17.05.01
A174003.52.00 60 350 M20x1.5
A174003.53.00 60 350 M24x1.5
A174403.51.00 100 350 M30x2
A174803.51.00 150 300 M36x2
A175203.51.00 200 300 M42x2
HBS Oleoidraulica

20 Valvole fine corsa - End stroke valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A200402.01.00 60 450 1/2"g 20.01.01


P
A200601.03.00 60 320 3/4"G 20.01.02
A200801.01.00 150 350 1"G
A201001.01.00 220 350 1-1/4"G

B A200401.02.00 80 400 1/2"G 20.02.02


A200401.05.00 80 400 1/2"G 20.02.03
A200301.01.00 60 400 3/8"G 20.02.04
A200401.07.00 80 400 1/2"G 20.02.05
A200401.08.00 80 400 1/2"G 20.02.06

A200601.01.00 100 400 3/4"G 20.03.01


B

A1 B1
A200400.01.00 60 350 1/2"G 20.03.02

A0 B0

A200401.09.00 80 400 1/2"G 20.03.03


B

A200301.02.00 40 350 3/8"G 20.03.04


D1

C1
Hydraulic valves

Pulsanti 3 vie 2 posizioni - 3 way, 2 position switches 30

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A300102.02.00 5 400 1/8"G 30.01.01


A300102.01.00 5 400 1/8"G 30.01.02
U

P T

Pulsanti 3 vie 2 posizioni - 3 way, 2 position switches 60

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A600000.40.00 5 350 1/8"G 60.01.01


U

P S

A600000.41.00 5 350 1/8"G 60.02.01


P

S U

A600000.42.00 5 350 1/4"G 60.03.01


P

T
HBS Oleoidraulica

60 Valvole di messa a scarico - Unload valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A600000.60.00 60 350 1/2"G 60.04.01


A600000.62.00 80 350 3/4"G 60.04.01A

A600000.67.00 30 400 1/2"G 60.07.02

Pil
A
B

A600000.63.00 150 350 1"G 60.04.01B

S
Hydraulic valves

Valvole speciali - Special valves 60

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

Pil A600014.04.00 60 350 1/2"G 60.11.03


M

RS P

PALA
PACKER BLADE
CARRELLO
CARRIER
A600050.29.00 150 400 3/4"G 60.07.01

A1 B1
M1
6 (280 bar)
4

5 (300 bar)

A2 A2

B2 3 (350 bar) B2
2

T3 T2

T1
1 (175 bar)

T A B

A600011.05.00 30 500 1/4"G 60.08.01


T P

T P
A600011.11.00 30 500 1/4"G 60.08.02

0.3

S1 S

12 3 4
A600014.06.00 20 350 1/4"G 60.09.01

A600014.10.00 - - 1/4"G 60.10.01


A600014.11.00 - - 1/4"G

S
HBS Oleoidraulica

60 Valvole speciali - Special valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

A600012.10.00 - 500 1/4"G 60.11.01


DISCESA SECONDARIO

P2
T2 RS
0.4

RIENTRO SFILO
E S2 0.3

S1
P
T P1
0.3
T1
DP

US
SS

A600014.36.00 - 450 1/4"G 60.11.02


SIMULATORE DI CARICO
(NORM.CHIUSO) RUBINETTO DI EMERGENZA
(NORM.APERTO)

M
F
SEGNALE
DI PERICOLO

DP RS
RIENTRO SFILI

SEGNALE DA INIBIRE
(PER ES. : DISCESA DEL PRIMARIO)

A600050.27.00 150 300 3/4"G 60.12.01


A1 B1
M2 M3
2

1 250 bar

0.8
3 4

250 bar
M1

P T

B600000.49.00 - 210 M18x1.5 60.13.01

U E

A B A602301.01.00 40 350 CETOP 3 60.14.01

1 2

R R

P T

A602401.01.00 80 210 CETOP 5 60.14.02

A B

TA P TB
Hydraulic valves

Valvole speciali - Special valves 90

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

U1 U2
A900400.01.00 - 350 1/2"G 90.01.01
A900600.01.00 - 350 3/4"G
A900800.01.00 - 350 1"G

D1 D2

U1 U2
A900600.02.00 150 350 3/4"G 90.01.02

0.5 Bar

D1 D2

A908200.01.00 150 350 3/4"G-3/4" SAE 6000 90.01.03


A908400.01.00 - 350 1G-1 SAE 6000 90.01.04

U1 U2

0.5 Bar 0.5 Bar

D1 D2

A900800.04.00 - 350 1"G-1" SAE 6000 90.01.05


U1 U2

0.5 Bar 0.5 Bar

V1 D V2

A900607.01.00 120 350 1"G 90.02.01


90 Valvole speciali - Special valves

Codice Q max. P max. Attacchi Pag. Catalogo


Code l/min. Bar Port size Pag. Catalogue

B900412.01.00 55 210 1/2"G-3/8"G 90.03.01

C A900612.01.00 120 - 3/4"G 90.03.02


Vmax A900812.01.00 200 - 1"G 90.03.02A
M

Cpil

Vuni VMS T

P2-AP P1-BP

A900600.03.00 90 350 3/4"G 90.05.00


M1 M

2 4 A

1
P

A903710.01.00 - 250 M18X1.5 90.06.00

B A

B900301.01.00 45 250 3/8"G 90.07.00


V2

C2 1 2 6 C3
1
R=8:1 R=5:1

C1 4
B C4
2

3
R=5:1
A 5

V1
Introduzione - Introduction

Introduzione
Introduction

PROGRAMMA DI PRODUZIONE PRODUCTION RANGE


La gamma di produzione della HBS com- The HBS S.p.a production range includes
prende valvole di varia tipologia, costru- different types and styles of valves,
ite per essere utilizzate come prodotti manufactured to be considered as
standard, pertanto non sono considera- standard items, therefore they cannot
te come quasi macchine o componenti be considered as partial machines or
di sicurezza e sono per questo escluse safety components and for this reason
dallambito della direttiva macchine they are excluded from the domain of
2006/42/CE. the EEC European Directive 2006/46/CE.

Le valvole hbs non debbono essere The hbs valves cannot be used on the
messe in servizio fino a quando la mac- machine until the complete machine
china finale su cui deve essere incorpo- has been verified to be compliant with
rata non sia stata dichiarata conforme the requirements of the eec european
a tutte le disposizioni della direttiva directive 2006/46/ce.
2006/42/ce sulla sicurezza dellle mac-
chine. Cartridge valves
This valves must at all times be installed
Valvole a cartuccia into specified cavities as shown in
Valvole per il montaggio diretto dentro the HBS catalogue. The valves can be
apposite cavit ricavate direttamente mounted directly into the actuator body
nellattuatore o in appositi collettori. Le or external inline bodies. The internal
parti interne sono in acciaio trattato ter- components of the valves are made
micamente. Nel montaggio rispettare le in hardened steel. Please refer to the
coppie di serraggio indicate a catalogo. assembly torques figures shown in this
In caso di assemblaggio sui collettori in catalogue to secure the valves into the
materiale diversi o con trattamenti anti- cavities in the manifolds. In case the
corrosione diversi da quelli utilizzati da cartridges are not being used in steel or
HBS, contattare il ns. uff. Tecnico. aluminium manifolds, or with different
external coating from the treatment
Per il corretto funzionamento delle val- used by HBS, please contact our
vole a cartuccia, le cavit devono rispet- technical department for the relevant
tare rigorosamente le indicazioni a ca- new torque values. To ensure the
talogo, essere prive di trucioli interne e correct performances of the cartridge
bave di lavorazione. Oliare le guarnizioni valves, cavities must correspond to the
prima del montaggio della cartuccia, in- catalogues indications and be absolutely
serire la cartuccia nella cavit e avvitare cleaned to ensure that there are no
a mano fin quando possibile (lunica markings or burs left on the surfaces
resistenza incontrata dovrebbe essere before fitting the valves. Lubricate the
data dalla resistenza delle guarnizioni). cartridge seals before assembling, insert
Introduzione - Introduction

Serrare a coppia con chiave dinamome- the cartridge manually and screw it until
trica e tararla al banco. Al termine riveri- the operator feels the seals resistance.
ficare la coppia di serraggio. Lock the cartridge with a torque wrench
and set the valve on the test rig. After
Valvole con collettore final testing please check again the
Sono formate da un corpo contenente torque setting.
una valvola a cartuccia o in parti sciolte.
Integral valves within manifolds or
Il corpo valvola generalmente in ac- bodies
ciaio o a richiesta in alluminio estruso. I They basically consist of a steel body
collettori in acciaio sono disponibili con with a cartridge or loose parts fitted
trattamento anticorrosione di zinca- inside. The valve housing is normally
tura esavalente bianca. Le valvole con manufactured in steel or upon request
collettore in acciaio hanno il codice pre- from an aluminium extruded bar. Steel
ceduto dalla lettera A. bodies are available with external
anticorrosion protection treatment with
I collettori in alluminio, sono adatti solo white equivalent zinc coating.
per applicazioni nelle quali la pressione The ordering code of steel body valves
massima viene raggiunta saltuariamen- starts with the letter A. Aluminium
te o su macchine con bassa frequenza bodies are only suitable to be used in
di cicli di lavoro, max 60 cicli giorno. A applications where the max pressure
richiesta sono forniti anodizzati color is rarely reached or with low working
nero. Altri colori disponibili a richiesta. frequency (max 60 cycles per day). On
Hanno il codice preceduto dalla lette- request the manifolds can be supplied
ra B. Le valvole con collettore sono with black anodizing treatment. Other
munite di attacchi per il collegamento colours available on request. The
al resto del circuito. Gli attacchi sono ordering codes start with letter B. In
generalmente del tipo BSPP, altre filet- general the valves in manifolds have
tature sono disponibili a richiesta. Le the ports for the connection into the
valvole sono anche disponibili a richie- hydraulic circuit. The ports are normally
sta con attacchi flangiati e con attacchi BSPP types. Other ports are available
flangiati SAE 3000 o SAE 6000. upon request such as valves which are
also available in flangeable version with
Sia per le valvole a cartuccia, che quelle SAE 3000 or SAE 6000 ports.
con corpo montano guarnizioni in NBR All types of valves, cartridges or in
o Buna-N idonee a lavorare con tem- bodies, are fitted with NBR or Buna-N
peratura da -20C a +90C, guarnizioni seals, suitable for working with
in Viton sono disponibili a richiesta. temperatures between -20C and +90C.
Consultare lufficio tecnico per tempe- Viton seals are available on request.
rature al di fuori di questo campo. Le Should the valves be used above the
valvole a cartuccia o con collettore non temperature range indicated, please
richiedono un verso di orientamento contact our technical department.
nel montaggio. The mounting position for the valves is
unrestricted.
Fluidi compatibili - filtraggio -
trafilamenti Fluids - filtering - leakage
Le valvole Hbs sono idonee a lavorare HBS valves are designed to work with
con oli a base minerale con caratteri- Mineral Oil for all standard hydraulic
stiche chimiche fisiche idonee alluso equipments such as pumps, motors,
Introduzione - Introduction

con componenti oleodinamici standard cylinders. In order for the correct


(pompe, distributori, cilindri motori). function of the valves it is essential that
Il corretto funzionamento delle valvo- the filtration of the oil is kept to the
le HBS dipende dal grado di filtrazione levels of filtration stated between NAS
dellolio utilizzato. Si raccomandano 8 and 11. (see chart). HBS recommends
i seguenti campi di contaminazione these max contamination levels as
massimi: follows:

Tipo di valvola - impianto / Valve - Application ISO 4406 NAS

Valvole per impieghi a pressioni superiori a 250 bar


o con pilotaggi interni o uso continuo.
17/14 8
Valves used with pressure over 250 bar, with
internal pilot connections, or with continous duty.

Valvole per impieghi intermittenti e pressioni


fino a 250 bar.
18/14 9
Valves for intermitted cycles or pressure
up to 250 bar.

Valvole per impieghi con pressioni inferiori a 100 bar.


19/16 11
Valves to be used below 100 bar.

Le valvole HBS hanno elementi di tenu- HBS valves have metallic seats without
ta metallo su metallo, che garantiscono seals. They can produce a very low oil
una tenuta con trafilamento quasi nullo, leakage path across the seats. Some of
alcune valvole possono per presenta- them can show a maximum leakage of
re un trafilamento fino a 5 gocce/min 5 drops per minute (1 cm3= 20 drops)
(1cm3/min=20 gocce) senza che questo without any fault in their performances.
ne pregiudichi la corretta funzionalit.
SETTINGS
TARATURE The setting values in the catalogue are
Le tarature riportate a catalogo sono referred to as using and hydraulic oil
effettuate con portata di 5dm3/min e with a viscosity of 16 Centistokes at
olio con viscosit di 16 cSt. A richiesta le flow rate of 5l/min. Different settings
valvole possono essere fornite tarate ai are available on request.
valori richiesti dal Cliente. HBS test rigs have a minimum filtration
level of NAS 8. If setting valves up on site,
Lolio utilizzato per la taratura ha grado do not exceed the range shown in the
minimo di filtrazione corrispondente a catalogue and protect the setting with a
NAS 8. In caso di variazione della taratu- tamper proof sealing. Different types of
ra da parte dellutilizzatore finale, atte- tamper proof system are available upon
nersi ai valori minimi e massimi riportati request.
a catalogo e ripiombare le valvole. Di-
verse tipologie di piombature o sigilla- STORAGE
ture sono disponibili a richiesta. Valves should be kept only in rooms
Introduzione - Introduction

STOCCAGGIO VALVOLE with temperature ranges between -5C


Si consiglia di stoccare le valvole in am- and +45C. Protect the valves from the
biente con temperature minime non direct sun light and from sources of
inferiori a -5C e non superiori a +45C. ozone atmosphere and do not remove
Non esporre le valvole alla luce diret- the original plastic wrapping to avoid
ta del sole o in vicinanza di fonti che entrance of contamination and to keep
rilasciano ozono. Si consiglia di lascia- the internal components oiled and
re le valvole nel loro imballo originale protected.
per proteggerle dalla contaminazione
esterna. PERFORMANCE CURVES
The curves illustrated in the catalogue
CURVE CARATTERISTICHE pages are referred to the test made
Le curve riportate a catalogo fanno rife- by HBS. However small differences in
rimento ai risultati ottenuti con valvole practice do not affect the performances
di normale produzione, pertanto piccoli and reliability of the valves.
scostamenti dalle curve a catalogo pos-
sono essere riscontrate in utilizzo e non The curves available for every valve
compromettono la funzionalit e affida- are obtained utilizing mineral oil with
bilit delle stesse. Le curve fornite per vioscosity of 16 cSt, 50C of temparture,
ogni valvola sono state ottenute utiliz- and 20C of ambiental temperature.It
zando olio minerale con viscosit di 16 is Customers responsibility to test an
cSt a una temperatura di circa 50C con appropriate number of samples to prove
temperatura ambientale di 20C. re- the correct function of the valves. The
sponsabilit del Cliente verificare, con working condition of the Customers
prove funzionali su campionature Iido- machines cannot be completely
neit alluso della valvola sulla propria simulated during our approval tests on
attrezzatura. Le reali condizioni duso our in-house test rigs.
della attrezzatura Cliente non possono
essere sempre riprodotte fedelmente HBS confirms that all its products
durante i ns test. Tutta la produzione are individually tested during the
HBS controllata durante la produzione production and controlled according to
secondo le prescrizioni interne e collau- the internal quality procedure. Valves
data singolarmente. Le valvole devono have to be used for the application and
essere utilizzate per gli usi descritti nel- in respect of the technical specification
le specifiche tecniche a catalogo. shown in the catalogue.
Valvole limitatrici di pressione - Relief valves

Valvole limitatrici
di pressione
Relief valves

Le valvole limitatrici di pressione si mon- Pressure relief valves are installed generally
tano generalmente in derivazione fra un in derivation between a pressurized line
ramo in pressione e il serbatoio. and the tank.

Sono elementi normalmente chiusi, uti- Relief valves are normally closed elements
lizzati per: for the pressure control used to:
- limitare la pressione nel circuito oleodi- - limit the pressure in the circuit at the
namico al valore di taratura; setting value;
- proteggere gli elementi del circuito - protect the other elements (pumps,
(pompe, motori, cilindri, valvole, tubazio- cylinders, motors, other valves) from
ni, etc.) da picchi di pressione che potreb- pressure peaks that could damage
bero danneggiarli. them.

Al raggiungimento della pressione di When setting pressure is reached, the


taratura la valvola limitatrice mette in relief valve connects the line where is
comunicazione il ramo a cui collegata installed to the tank, avoiding to exceed
con lo scarico, evitando che in quel ramo the setting value in that line.
la pressione ecceda il valore di taratura.
HBS relief valves are available in two
Le valvole sono disponibili nelle versioni: versions:
- ad azione diretta; - direct;
- pilotate. - piloted.

Per portate elevate pi indicata la val- For greater flows, it is better to use the
vola pilotata in quanto la valvola ad azio- piloted valve, because the direct valve
ne diretta richiederebbe limpiego di un would require the use of a bigger body
corpo e di una molla molto grandi, con and a bigger spring, causing cumbersome
problemi di ingombro, difficolt di tara- problems, setting difficulty and response
tura e lentezza di risposta. slowness.

Inoltre le valvole limitatrici di pressione Moreover, HBS pressure relief valves


HBS possono essere: can be:
Valvole limitatrici di pressione - Relief valves

- singole per controllare la pressione su - single, to control the pressure on only


un solo ramo. one line of the circuit.

Valvola limitatrice di pressione Valvola limitatrice di pressione


non compensata singola pilotata
Single relief valve not compensated version Pilot operated single relief valve

- doppie a scarico incrociato per control- - dual crossed download, to control both
lare i due rami di un circuito. lines of the circuit.

Valvola limitatrice di pressione doppia Esempio di unapplicazione


Dual relief valve Application example

Nel caso delle valvole doppie incrociate In case of dual valves is necessary to
occorre notare che: note that:
- se utilizzate su attuatori con cilindrate - if used with actuators with the same
uguali nei due versi di movimento, scari- capacity in both the work directions,
cano lolio direttamente sul ramo oppo- they download the fluid directly by the
sto, sia con distributori a centro aperto opposite line, both with open center and
che a centro chiuso; closed center;
- se utilizzate su attuatori con cilindrate - if used with different capacity actuators
diverse e con distributori a centro chiu- and closed center spool, is essential to
so, indispensabile prevedere lo smalti- consider to drain the exceeding flow
mento della portata eccedente a scarico downstream the valve and to install
e installare valvole anticavitazione. anti-cavitation valves.
Valvole limitatrici di pressione - Relief valves

Le valvole anticavitazione non sono ne- Anti-cavitation valves are not needed with
cessarie con distributori a centro aperto. open center spool valves.
HBS dispone anche di una serie di valvole HBS can also provide direct cartridge
limitatrici di pressione dirette a cartuccia. pressure relief valves.

Sono disponibili nella versione: These are available in two versions:


- non compensata; - not compensated;
- compensata. - compensated.

Queste ultime grazie alla particolare moda- The compensated valves, thanks to the
lit costruttiva sono insensibili a eventuali particular way they are created, are not
contropressioni presenti sullo scarico. Ci affected by back pressure downstream
assicura che la valvola si apra esattamente the valve. This effect guarantees that
alla pressione di taratura impostata. the valve opens exactly at the setting
pressure value.

Valvola limitatrice di pressione singola compensata


Single relief valve compensated version

Caratteristiche delle valvole limitatrici The features of HBS pressure relief valves
di pressione HBS sono: are:
- ridotti tempi di risposta; - reduced response time;
- ampio campo di tarature; - wide setting range;
- possibilit di sigillatura anti-effrazione. - seal opportunity.
Pag. 01.01.01

Valvola limitatrice di pressione


Relief valve

L
P P
L4 E1

E2

T
CURVE CARATTERISTICHE
PERFORMANCE CURVES

H3
D (n2)

H
3/8"G - 1/2"G T

Y
taratura/setting taratura/setting
40-150 (bar) 100-350 (bar)
p (bar)

H1
200 400
150 300
P P

H5
100 200

Y
50 100
PRESSIONE / PRESSURE -

H2

H4
0 60/0 0
10 20 30 40 50 10 20 30 40 50 60
L3 L1
3/4"G L2
taratura/setting taratura/setting
40-150 (bar) 100-320 (bar)
200 400
150 300
100 200
50 100
0 150 0
30 60 90 120 0 30 60 90 120 150

PORTATA / FLOW - Q (l/min)


Corpo in acciaio / Steel body
65 40 59 19 40 ~167.5 100 29 29 16.5 25 HEX5 6.5 HEX17 3/4"G
50 35 45 14 30 ~108 65 16 24 10 20 HEX4 6.5 HEX13 1/2"G
50 30 45 14 30 ~104 60 15 20 9 20 HEX4 6.5 HEX13 3/8"G
L L1 L2 L3 L4 H H1 H2 H3 H4 H5 E1 D E2 Y

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact steel


con tenuta ad otturatore, construction poppet type,
con funzione di protezione for overload protection.
del circuito da sovrapressioni. Two adjustance pressure
Disponibile con due dierenti ranges.
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003 916005
3/8"G - 1/2"G 3/4"G

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010301.01.00 40-150 bar 80 bar 25 bar/turn 50 l/min 400 bar 3/8"G 0.6 kg
A010301.02.00 100-350 bar 250 bar 100 bar/turn 50 l/min 400 bar 3/8"G 0.6 kg
A010401.01.00 40-150 bar 80 bar 25 bar/turn 65 l/min 400 bar 1/2"G 0.8 kg
A010401.02.00 100-350 bar 250 bar 100 bar/turn 65 l/min 400 bar 1/2"G 0.8 kg
A010601.01.00 40-150 bar 80 bar 41 bar/turn 150 l/min 400 bar 3/4"G 1.5 kg
A010601.02.00 100-320 bar 250 bar 69 bar/turn 150 l/min 400 bar 3/4"G 1.5 kg
Pag. 01.01.03
00.00.00

Valvola limitatrice di pressione


Relief valve

T L
L1

L4 HEX4

HEX13

H1
P2 P1

D (n2)
CURVE CARATTERISTICHE

Y
PERFORMANCE CURVES
1/2"G

H
taratura/setting taratura/setting
40-150 (bar) 100-350 (bar)

H4
200 400 P2 P1

H2

Y
p (bar)

Y
150 300

H3
100 200
50 100
L2 L3
PRESSIONE / PRESSURE -

0 0
10 20 30 40 50 60/0 10 20 30 40 50 60
3/4"G
taratura/setting taratura/setting
40-150 (bar) 100-320 (bar)
200 400
150 300
100 200
50 100
0 0
30 60 90 120 150
0 30 60 90 120 150

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


70 40 8 54 32.5 90 70 45 20 70 8.5 3/4"G
70 35 6 58 35 78 43 39 20 60 6.5 1/2"G
L L1 L2 L3 L4 H H1 H2 H3 H4 D Y

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact


con tenuta ad otturatore, aluminium
con funzione di protezione construction poppet type, for
del circuito da sovrapressioni. overload protection.
Disponibile con due dierenti Two setting ranges available.
campi di taratura.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B010401.11.00 40-150 bar 80 bar 25 bar/turn 65 l/min 350 bar 1/2"G 0.8 kg
B010401.12.00 100-350 bar 250 bar 100 bar/turn 65 l/min 350 bar 1/2"G 0.8 kg
B010601.11.00 40-150 bar 80 bar 41 bar/turn 150 l/min 350 bar 3/4"G 1.5 kg
B010601.12.00 100-320 bar 250 bar 69 bar/turn 150 l/min 350 bar 3/4"G 1.5 kg
Pag. 01.01.04

Valvola limitatrice di pressione


Relief valve

HEX5

HEX17

P P

H1
T

H
H3
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

H2
P P
H4

400

300 = = L2 L1 L2

S L
200
D (n2)
100
=

0
20 40 60 80 100
=

PORTATA / FLOW - Q (l/min)

L3

Corpo in acciaio / Steel body


A010401.05.00 70 58 6 32 35 90 66.5 max 39 40 20 6.5
A010601.04.00 70 54 8 32 40 90 67 max 45 50 20 8.5
COD. L L1 L2 L3 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact


con tenuta a cono, steel construction
con funzione di protezione poppet type, for
del circuito da sovrapressioni. overload protection.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003-916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010401.05.00 100-300 bar 200 bar 75 bar/turn 70 l/min 350 bar 1/2"G 1.6 kg
A010601.04.00 150-380 bar 200 bar 75 bar/turn 100 l/min 400 bar 3/4"G 1.7 kg
Pag. 01.01.05

Valvola limitatrice di pressione


Relief valve

L
P L1 P

P P

S
S1
D (n2)
HEX4
T
HEX13

CURVE CARATTERISTICHE L2
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

T
300

H2
250
F1

200

H1
150

F
F

100 H

50
0
15 30 45 60 75 90
PORTATA / FLOW - Q (l/min) P
P
= = = =

Corpo in acciaio / Steel body


A010401.04.00 65 32.5 8.5 30 15 80 30 8 59 24.5 8.5
COD. L L1 L2 S S1 H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve with piloted


con otturatore pilotato, spool in compact steel
con funzione di protezione construction poppet type,
del circuito da sovrapressioni. for overload protection.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010401.04.00 100-350 bar 100 bar 65 bar/turn 90 l/min 350 bar 1/2"G 1 kg
Pag. 01.02.01

Valvola limitatrice di pressione doppia incrociata


Dual cross-overrelief valve

L1 L2 HEX4 S
A A
HEX13

B B

CURVE CARATTERISTICHE A A
PERFORMANCE CURVES

Y
p (bar)

3/8"G - 1/2"G

H3

H2
taratura/setting taratura/setting
H
40-150(bar) 100-350(bar) D (n2)
PRESSIONE / PRESSURE -

200 400
H1
Y

Y
150 300

H4
100 200 B B
50 100

0 50 0
10 20 30 40 10 20 30 40 50

PORTATA / FLOW - Q (l/min)


L3 L4

Corpo in acciaio / Steel body


80 21 29.5 60 10 30 80 40 ~155 40 20 6.5
L L1 L2 L3 L4 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction poppet
ad otturatore, con funzione type, for overload protection.
di protezione del circuito Two setting ranges available.
da sovrapressioni.
Disponibile con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010302.01.00 40-150 bar 80 bar 25 bar/turn 50 l/min 400 bar 3/8"G 1.3 kg
A010302.02.00 100-350 bar 250 bar 100 bar/turn 50 l/min 400 bar 3/8"G 1.3 kg
A010402.01.00 40-150 bar 80 bar 25 bar/turn 65 l/min 400 bar 1/2"G 1.3 kg
A010402.02.00 100-350 bar 250 bar 100 bar/turn 65 l/min 400 bar 1/2"G 1.3 kg
Pag. 01.02.02

Valvola limitatrice di pressione doppia incrociata


Dual cross-over relief valve

L
L2 L1 S
M1
L3 HEX4
A A
HEX13

L4

B B

H1
M2
M1
A A
D (n2)
CURVE CARATTERISTICHE

H3
PERFORMANCE CURVES
p (bar)

M2
3/8"G - 1/2"G
H2
B B
taratura/setting taratura/setting

H1
40-150(bar) 100-350(bar)
PRESSIONE / PRESSURE -

200 400
150 300 L4
100 200
50 100
0 0
10 20 30 40 50 10 20 30 40 50
L5
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


65 50 7.5 21 20 21 35 80 19 40 ~166 6.5
L L1 L2 L3 L4 L5 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction poppet
ad otturatore, con funzione type, for overload protection.
di protezione del circuito Two setting ranges available.
da sovrapressioni.
Disponibile con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010302.11.00 40-150 bar 80 bar 25 bar/turn 50 l/min 400 bar 3/8"G 1.3 kg
A010302.12.00 100-350 bar 250 bar 100 bar/turn 50 l/min 400 bar 3/8"G 1.3 kg
A010402.11.00 40-150 bar 80 bar 25 bar/turn 65 l/min 400 bar 1/2"G 1.3 kg
A010402.12.00 100-350 bar 250 bar 100 bar/turn 65 l/min 400 bar 1/2"G 1.3 kg
Pag. 01.02.03

Valvola di massima doppia incrociata


Dual cross-over relief valve

H
S
H1 H2 HEX5
D2 D2
HEX17

L1
D1 D1 D (n2)

D2
CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

L
D2 D2

L3

F
L2
taratura/setting 100-350(bar)
400
PRESSIONE / PRESSURE -

300 D1 D1

F1
D1
200

100
L4
L1

0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A010302.13.00 203 54 95 72 11.5 30 65 25 20 30 32.5 8.5
COD. L L1 L2 L3 L4 S H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction poppet
ad otturatore, con funzione type, for overload protection.
di protezione del circuito Two setting ranges available.
da sovrapressioni.
Disponibile con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010302.13.00 100-350 bar 180 bar 110 bar/turn 30 l/min 500 bar 3/8"G 1.4 kg
Pag. 01.02.04

Valvola limitatrice di pressione doppia incrociata


Dual cross-over relief valve

L3 L2
HEX 17 L4
= =

H1
C1
D1 C1

H3
HEX 5

H2
H
H3
C2
O-RING

D2 C2 = =
L4
L1 L L1

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

S
400
PRESSIONE / PRESSURE -

L6 L5
300

200 D2

100
H4

0 40 80 120 160 200


D (n4)
PORTATA / FLOW - Q (l/min)
H5

D1

Corpo in acciaio / Steel body


A010804.01.00 130 ~70 50 40 46.8 66 32 59 150 63 24 27 52 49 12.5 OR 3131 32.99x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 H4 H5 D O-RING

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction poppet
ad otturatore, con funzione type, for overload protection.
di protezione del circuito Two setting ranges available.
da sovrapressioni.
Disponibile con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A010804.01.00 100-350 bar 150 bar 90 bar/turn 200 l/min 350 bar 1"G 7.8 kg
Pag. 01.02.05

Valvola limitatrice di pressione doppia incrociata


Dual cross-over relief valve

HEX5
L
L1 L2 S HEX17
A A

H3
B B
B

H1

D (n2)
H4

H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
A

H2
200
PRESSIONE / PRESSURE -

150

100

H3
50

0 5 10 15 20 25 30
L4 L3 L4
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B010402.01.00 60 18 24 48 6 40 85 20.5 42.5 ~51 44 6.5
B010402.02.00 60 18 24 48 6 40 79 17.5 39.5 ~51 44 6.5
COD. L L1 L2 L3 L4 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve


doppia incrociata con tenuta in compact steel construction
ad otturatore, con funzione poppet type, for overload
di protezione del circuito protection. Two setting
da sovrapressioni. Disponibile ranges available.
con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B010402.01.00 40-150 bar 120 bar 57 bar/turn 30 l/min 250 bar 1/2"G 0.7 kg
B010402.02.00 40-150 bar 80 bar 25 bar/turn 30 l/min 250 bar 1/2"G 0.7 kg
Pag. 01.02.06

Valvola limitatrice di pressione doppia incrociata


Dual cross-over relief valve

S H3
D1 C1
S1 S2 S1 H1 H H2

L1
D2 C2

C1
D1

L4
CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

L3

L2
L
taratura/setting
40-150 (bar)
D2
200
PRESSIONE / PRESSURE -

L4

150 C2
HEX27
100

L1
50

HEX17
0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min) HEX5

Corpo in alluminio / Aluminium body


B010404.01.00 80 51 182 40 20 60 26 8 29.5 13.7 20.8 64
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 H3

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction
ad otturatore, con funzione poppet type, for overload
di protezione del circuito protection. Two setting
da sovrapressioni. ranges available.
Disponibile con due dierenti
campi di taratura.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B010404.01.00 40-150 bar 80 bar 25 bar/turn 30 l/min 250 bar 1/2"G 0.8 kg
Pag. 01.02.08

Valvola limitatrice di pressione doppia incrociata


Dual cross-over relief valve

HEX5 HEX17 S1 S2

S3 S4
VM1
B B

VM1

L1
A

H1
VM2

A A

H2
L2
A

F2
H3
L

H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES B

400
PRESSIONE / PRESSURE -

300

D(n2)
B
200
L1

100
VM2
0 40 80 120 160 200

PORTATA / FLOW - Q (l/min) F F1


= = = =
S

Corpo in acciaio/Steel body

A010802.01.00 110 ~82 37 100 80 10 34 32 90 10 30 50 44 28 73 9


COD. L L1 L2 S S1 S2 S3 S4 H H1 H2 H3 F F1 F2 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Dual relief valve in compact


doppia incrociata con tenuta steel construction poppet
ad otturatore, con funzione type, for overload protection.
di protezione del circuito
da sovrapressioni.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Setting Pressure Max Flow Max Port Size Weight
Range Increase Pressure
VM1 260 bar
A010802.01.00 100-350 bar 90 bar/turn 200 l/min 400 bar 1"G 3.9 kg
VM2 320 bar
Pag. 01.02.09

Valvola limitatrice di pressione angiabile doppia incrociata


Flangeable dual cross over relief valve

H1
O-RING

H
V2 C2
C2 C1
S
S1
V1 C1 HEX5 S2

S3 S3
HEX17

CURVE CARATTERISTICHE
PERFORMANCE CURVES V1
p (bar)

taratura/setting 40-150(bar)
200
PRESSIONE / PRESSURE -

L1
150

L
D
F
100

50
V2
L2

0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min) S3 S3

S2 S4
S1
Corpo in alluminio / Aluminium body
B016004.03.00 99 36 31.5 90 65 27 20 36 45 21 13.5 8.5 OR 22.22x2.62
COD. L L1 L2 S S1 S2 S3 S4 H H1 F D O-RING

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact


con tenuta a cono, aluminium construction
con funzione di protezione poppet type, for overload
del circuito da sovrapressioni. protection. Flangeable
Flangiata per motori for DANFOSS motors OMR.
DANFOSS OMR.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 1/2"G
B016004.03.00 40-150 bar 50 bar 25 bar/turn 30 l/min 250 bar 0.7 kg
C1-C2 9
Pag. 01.03.01

Valvola limitatrice di pressione a cartuccia a pressione compensata


Pressure compensated cartridge relief valve

SFIATO/AIR BLEED

HEX 17

CURVE CARATTERISTICHE HEX 22


PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

taratura/setting taratura/setting
40-150(bar) 100-350(bar)

100
200 400
150 300 M20X1.5
100 200
50 100
0 T
0
5 10 15 20 25 30/0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min) P


19

CODICE SEDE CAVITY CODE


HBS.38.S.02A (Pag. 99.08.02)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact steel


con tenuta a cono, con funzione construction poppet type, for
di protezione del circuito da overload protection. The back
sovrapressioni. La pressione sullo pressure downstream the valve
scarico non inuisce sul valore doesn't eect the setting.
di taratura della valvola.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

30 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
A013807.01.00 40-150 bar 80 bar 25 bar/turn 30 l/min 500 bar 0.2 kg
A013807.02.00 100-350 bar 220 bar 100 bar/turn 30 l/min 500 bar 0.2 kg
Pag. 01.03.02

Valvola limitatrice di pressione a cartuccia a pressione compensata


Pressure compensated cartridge relief valve

P HEX 5

HEX 17

CURVE CARATTERISTICHE HEX 22


PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

taratura/setting taratura/setting
40-150 (bar) 100-350 (bar)

100
200 400

150 300
M20X1.5
100 200

50 100
T
0 0
5 10 15 20 25 30/0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min) P

19

CODICE SEDE CAVITY CODE

HBS.38.S.02A (Pag. 99.08.02)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact steel


con tenuta a cono, con funzione construction poppet type,
di protezione del circuito da for overload protection. The back
sovrapressioni. La pressione sullo pressure downstream the valve
scarico non inuisce sul valore doesn't eect the setting.
di taratura della valvola.

CODICE ORDINAZIONE SEALING ORDERING COPPIA DI SERRAGGIO INSTALLATION TORQUE


PIOMBATURA CODE
916005 30 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
A013807.03.00 40-150 bar 80 bar 25 bar/turn 30 l/min 500 bar 0.2 kg
A013807.04.00 100-350 bar 220 bar 100 bar/turn 30 l/min 500 bar 0.2 kg
A013807.08.00 10-50 bar 35 bar 8 bar/turn 30 l/min 500 bar 0.2 kg
Pag. 01.03.03

Valvola limitatrice di pressione pilotata


Pilot operated relief valve

HEX5
P

HEX13

HEX22

80
M20X1.5
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

300

250
T

21
200

150

100 P

50

0 CODICE SEDE CAVITY CODE


15 30 45 60 75 90

PORTATA / FLOW - Q (l/min) HBS.38.M.02A (Pag. 99.04.00)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Piloted relief valve spool type


pilotata con funzione for overload protection.
di protezione del circuito
da sovrapressioni.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

30 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
A013807.11.00 60-300 bar 250 bar 65 bar/turn 80 l/min 350 bar 0.12 kg
Pag. 01.03.04

Valvola limitatrice di pressione pilotata


Pilot operated relief valve

HEX5
P

HEX17

45,5
HEX25

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES 1-14 UNS


400

300

200

56,9
100

0
30 60 90 120 150 T
PORTATA / FLOW - Q (l/min)

P
CODICE SEDE CAVITY CODE 19,05
HBS.99.S.02A (Pag. 99.08.00)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve with piloted spool


con otturatore pilotato con for overload protection
funzione di protezione del circuito in intermittetn duty circles.
da sovrapressioni accidentali.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

30 Nm

Codice Ordinazione Campo di Incremento Taratura Portata Pressione Max Peso


Taratura per Giro Standard Massima

Ordering Code Pressure Pressure Standard Setting Max Flow Max Pressure Weight
Range Increase
C019901.01.00 10-165 bar 17 bar 50 bar 150 l/min 350 bar 0.24 kg
C019901.02.00 100-350 bar 56 bar 350 bar 150 l/min 350 bar 0.24 kg
Pag. 01.03.05

Valvola limitatrice di pressione a cartuccia


Cartridge relief valve

HEX 4

HEX 13
P
HEX 24

~31,8

5
27,8
T
T

CODICE SEDE CAVITY CODE


P
HBS.93.U.02A (Pag. 99.01.00) 3/4-16UNF-2A

DESCRIZIONE DESCRIPTION

Valvola limitatrice di Relief valve in compact steel


pressione con tenuta a cono, construction poppet type,
con funzione di protezione for overload protection.
del circuito da sovrapressioni.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
A019307.01.00 40-150 bar 80 bar 87 bar/turn 3 l/min 350 bar 0.15 kg
A019307.02.00 100-350 bar 220 bar 150 bar/turn 3 l/min 350 bar 0.15 kg
Pag. 01.03.06

Valvola di massima pressione doppia incrociata


Dual cross-line max pressure valve

HEX 5

HEX 17

B HEX 22

CURVE CARATTERISTICHE 25
PERFORMANCE CURVES

80
taratura/setting
10-210(bar)
PRESSIONE / PRESSURE - p (bar)

250

112
200

150

100

50
14

0
15 30 45 60 7/8-14UNF-2B
B
18

PORTATA / FLOW - Q (l/min)

CODICE SEDE CAVITY CODE A

HBS.94.U.02A (Pag. 99.01.00)

DESCRIZIONE DESCRIPTION

Valvola limitatirice di pressione Dual cross-over relief valve.


doppia incrociata. Massima Maximum dierence between
dierenza tra le due direzioni: the two directions: 15 bar.
15 bar. La pressione alla porta The backpressure has to be
di scarico va sommata alla added to the setting value.
taratura della valvola.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C010203.01.00 10-210 bar 160 bar 33 bar/turn 60 l/min 250 bar 0.17 kg
Pag. 01.03.07

Valvola limitatrice di pressione pilotata


Pilot operated relief valve

P
13

HEX24

T
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
400

47,6
300

200

100

0
40 80 120 160 200

PORTATA / FLOW - Q (l/min)


22,22
1-14UNS-2A
CODICE SEDE CAVITY CODE
HBS.99.S.02B (Pag. 99.08.00)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve with piloted spool


con otturatore pilotato con for overload protection
funzione di protezione del circuito in intermittent duty cycles.
da sovrapressioni accidentali.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

65 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima
Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C019902.02.00 40-150 bar 100 bar 87 bar/turn 200 l/min 350 bar 0.2 kg
C019902.04.00 100-350 bar 300 bar 150 bar/turn 200 l/min 350 bar 0.2 kg
Pag. 01.03.08

Valvola limitatrice di pressione pilotata


Pilot operated relief valve

P
13

T HEX24

CURVE CARATTERISTICHE 32
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
400

300

200

45
100
T
0
40 80 120 160 200

PORTATA / FLOW - Q (l/min)


P
22,22
1 1/16-12 UN-2A
CODICE SEDE CAVITY CODE
HBS.96.U.02A (Pag. 99.01.01)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di Relief valve with piloted


pressione con otturatore spool for overload protection
pilotato con funzione in intermittetn duty cycles.
di protezione del circuito
da sovrapressioni accidentali.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

85 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima
Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C019602.01.00 40-150 bar 100 bar 87 bar/turn 200 l/min 350 bar 0.25 kg
C019602.02.00 100-350 bar 300 bar 150 bar/turn 200 l/min 350 bar 0.25 kg
Pag. 01.03.09

Valvola limitatrice di pressione a cartuccia


Cartridge relief valve

HEX 39

CURVE CARATTERISTICHE

100
PERFORMANCE CURVES
taratura/setting HEX 41
PRESSIONE / PRESSURE - p (bar)

150-350(bar)
400

350

12
250

200 50
P
150

0
50 100 150 200 T
28
PORTATA / FLOW - Q (l/min)
1"G

CODICE SEDE CAVITY CODE

HBS.08.G.02A (Pag. 99.07.01)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact steel


con tenuta a cono, con funzione construction poppet type,
di protezione del circuito da for overload protection.
sovrapressioni.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

200 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima
Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C010801.01.00 150-350 bar 350 bar 88 bar/turn 240 l/min 420 bar 0.48 kg
Pag. 01.03.10

Valvola limitatrice di pressione a cartuccia


Cartridge relief valve

HEX 27

HEX 27
T

CURVE CARATTERISTICHE

117
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

taratura/setting
70-210(bar)
250

200
150

37
100 T

50

0
P
30 60 90 120
23,5
PORTATA / FLOW - Q (l/min)
3/4"G

CODICE SEDE CAVITY CODE

HBS.06.G.02A (Pag. 99.07.01)

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Relief valve in compact steel


con tenuta a cono, con construction poppet type,
funzione di protezione for overload protection.
del circuito da sovrapressioni.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

120 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima

Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C010601.01.00 70-210 bar 120 bar 70 bar/turn 120 l/min 210 bar 0.45 kg
Valvole riduttrici di pressione - Reducing/relieving valves

Valvole riduttrici
di pressione
Reducing/relieving valves

Le valvole riduttrici di pressione servo- The pressure reducing valves are used
no per mantenere una pressione ridot- to maintain a reduced pressure in a part
ta in una parte del circuito secondario of the secondary circuit compared to the
rispetto alla pressione di alimentazione inlet pressure of the circuit controlled by
del circuito controllata da una valvola di a main relief valve. Therefore, if in a circuit
massima principale. Quindi, se in un cir- with 2 or more cylinders, some of these
cuito con 2 o pi cilindri, alcuni di questi have to work at a lower pressure than
devono lavorare ad una pressione infe- the one set on the main relief valve, by
riore a quella impostata sulla valvola di means of this type of valve, it is possible
massima principale, attraverso questo to decrease the operating pressure to
tipo di valvola si riesce a diminuire la the required value. It is normally open
pressione di esercizio al valore deside- valves that, when the pressure on the
rato. Si tratta di valvole normalmente secondary branch exceeds the value
aperte che nel momento in cui la pres- set with the adjusting spring, through a
sione sul ramo secondario supera il valo- cylindrical spool, go to intercept the flow
re impostato con la molla di regolazione, of oil between the main and secondary
attraverso una spola cilindrica, vanno branch; in this way, you generate a
ad intercettare il flusso dolio tra ramo choke, which reduces the pressure in the
principale e secondario; in questo modo output, ensuring the limitation and the
viene generata una strozzatura, che ri- maintenance of reduced pressure.
duce la pressione in uscita, garantendo
la limitazione e il mantenimento della
pressione ridotta.
Valvole riduttrici di pressione - Reducing/relieving valves

Come per le valvole limitatrici di pressio- As for the pressure relief valves, there
ne, esistono 2 tipi di allestimento: valvo- are 2 types of equipment: direct valves
le dirette e valvole pilotate o a doppio and pilot operated valves or double sta-
stadio. Le prime risultano pi semplici e ge. The first are more simple and for this
per questo robuste e affidabili ma, dato robust and reliable but, as the pressure
che la pressione da regolare agisce di- to be controlled acts directly onto the
rettamente sulla spola, non sono adatte spool, they are not suitable for use in cir-
allutilizzo in circuiti con passaggio con- cuits with a continuous flow of oil but ra-
tinuo di flussi di olio ma piuttosto per le ther for pilot lines (with low flow rates).
linee di pilotaggio (con basse portate).

P T P T

R R
Valvola riduttrice di pressione diretta Direct acting reducing/relieving valve
Valvole riduttrici di pressione - Reducing/relieving valves

Le valvole a doppio stadio, invece, aven- The two-stage valves, contrariwise, ha-
do un elemento logico controllato da ving a logic element controlled by a dri-
uno stadio pilota sul quale agisce la ver stage on which acts the pressure to
pressione da regolare, sono in grado di be controlled, are able to dispose also
smaltire anche alte portate di olio. high a flow of oil.

P T P T

R R
Valvola riduttrice di pressione pilotata Pilot operated reducing/relieving valve

In entrambe le configurazioni si tratta In both configurations, it is three-way


di valvole a tre vie con una linea di dre- valves with a drain line that is suggested
naggio che si consiglia di collegare diret- to connect directly to tank because, a
tamente a scarico perch uneventuale possible pressurizing of the said line,
pressurizzazione della suddetta linea va goes to increase the set pressure.
ad aumentare la pressione di taratura.
Pag. 02.01.01

Valvola riduttrice di pressione a cartuccia


Reducing/relieving valve cartridge type

P T HEX5

HEX17

52,3(55 max)
HEX24

R
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
60

10,5
45 M18x1,5

30 T
15

40
0 2 4 6 8 10 15
P
PORTATA/FLOW - Q(l/min)

14
R
CODICE SEDE CAVITY CODE
HBS.37.M.03A (Pag. 99.05.00)

DESCRIZIONE DESCRIPTION

Valvola riduttrice di pressione Pressure regulator with


con la funzione di ridurre la the function of reducing
pressione in uscita dalla valvola the output pressure from
(R), permette il controllo quindi the valve (R), allows control
della pressione e di regolarla of the pressure and then
a piacimento. to regulate it at will.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Max Peso


Taratura Standard per Giro Massima
Ordering Code Pressure Range Standard Pressure Max Flow Max Pressure Weight
Setting Increase
C023701.01.00 15-45 bar 20 bar 10.5 bar/turn 10 l/min 350 bar 0.18 kg
C023701.02.00 35-80 bar 70 bar 25 bar/turn 10 l/min 350 bar 0.18 kg
Valvole di sequenza - Sequence valves

Valvole
di sequenza
Sequence valves

Le valvole di sequenza sono elementi Sequence valves are elements that open
che devono aprirsi al raggiungimento di when an established pressure value is
una pressione prestabilita, consentendo reached, allowing the fluid to pass to
il passaggio del fluido in unaltra parte another part of the circuit. Therefore
dellimpianto idraulico. La loro apertura the opening depends upon the existing
dipende quindi dalla pressione esistente upstream pressure. The pressure in the
nel loro condotto di ingresso. La pres- circuit that provokes the opening is kept
sione nel circuito che ha provocato la- equal to the setting value, when the
pertura viene mantenuta inalterata ed valve is open.
uguale a quella di taratura, durante la- When pressure upstream decreases
pertura della valvola. Quando la pressio- under the setting pressure value, the
ne nel condotto di ingresso scende sotto valve closes.
il valore di taratura, la valvola si chiude.

C C

D D

Dirette non compensate Diretta compensata


Direct not compensated Direct compensated
Valvole di sequenza - Sequence valves

Tali valvole vengono utilizzate, ad esem- Such valves are used, for example, when
pio, quando necessario far muovere gli is necessary to move the actuators of a
attuatori di un circuito idraulico secondo circuit with an established order, when
un ordine prestabilito, al raggiungimen- a determined pressure value is reached.
to di un determinato valore di pressione. A check valve allows to shortcut the
Una valvola unidirezionale permette di system when there is flow in the
cortocircuitare il sistema quando si ha il opposite direction.
flusso nel verso opposto.
Sono disponibili nelle versioni: These valves are available in two versions:
- dirette non compensate; - direct not compensated;
- dirette compensate: insensibili alla con- - direct compensated, not affected by the
tropressione che pu esserci nel ramo possible back pressure on the other side.
secondario.

Caratteristiche: Features:
Vengono realizzate sia con corpo e co- They are realized both with body and
lonnetta, sia in corpi esagonali, con ri- stud bolt, and hexagonal body, obtaining
dotti ingombri e adatti ad essere monta- reduced cumbersome and suitability to
ti in linea con i tubi. be installed in line with the pipes.

Presentano: These valves offer:


- Ampio campo di taratura; - Wide setting range;
- Ridotti tempi di apertura e chiusura; - Reduced response time;
- Ridotte perdite in attraversamento. - Reduced pressure drops.

Le curve a catalogo mostrano le perdite In the catalogue are shown the pressure
di carico nelle due direzioni D>C e C>D drops curves for both the directions D>C
con molla senza precarico. and C>D, and they are related to the
valve spring with no preload.
Con valori di taratura uguali o inferiori al If the valve is set at the lowest setting
valore minimo di catalogo le valvole pos- value or below the value indicated in the
sono presentare instabilit e rumorosit. catalogue, instability and noise can occur.
Pag. 04.01.01

Valvola di sequenza compensata


Pressure compensated sequence valve

L2
C

SFIATO/AIR BLEED

L
L1
D

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

4
PRESSIONE / PRESSURE -

3 C

2 C
D
D
1

HEX 27

HEX 30
C
0 10 20 30 40

PORTATA / FLOW - Q (l/min)

91.5 83 8
L L1 L2

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve with adjustable


con taratura regolabile. setting. Available with two
Disponibile con due dierenti dierent outlet ports.
attacchi d'estremit.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A040201.01.00 40-160 bar 60 bar 38 bar/turn 20 l/min 500 bar 1/4"G 0.35 kg
A040301.01.00 40-160 bar 75 bar 38 bar/turn 40 l/min 500 bar 3/8"G 0.33 kg
A040301.02.00 100-280 bar 150 bar 66 bar/turn 40 l/min 500 bar 3/8"G 0.33 kg
Pag. 04.01.02

Valvola di sequenza compensata


Pressure compensated sequence valve

F1
D C

L
E1

F
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
10
C
PRESSIONE / PRESSURE -

8
6
4 C D
D C
2

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)
E

Corpo in acciaio / Steel body


A040401.17.00 111 38 42 HEX36 HEX34
COD. L F F1 E E1

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A040401.17.00 50-150 bar 90 bar ~30 bar/turn 60 l/min 500 bar D, C 1/2"G 0.8 kg
Pag. 04.01.04

Valvola di sequenza compensata


Pressure compensated sequence valve

D C F1

L
E1
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
F
10
PRESSIONE / PRESSURE -

8 C
6
C D
4
D C
2

0 20 40 60 80 100 120

PORTATA / FLOW - Q (l/min)


E

Corpo in acciaio/Steel body

A040601.14.00 124 38 42 HEX36 HEX34


A040601.15.00 124 38 42 HEX36 HEX34
A040601.18.00 124 38 42 HEX36 HEX34
COD. L F F1 E E1

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A040601.14.00 50-120 bar 90 bar ~30 bar/turn 120 l/min 500 bar D, C 3/4"G 0.8 kg
A040601.15.00 150-280 bar 150 bar ~46 bar/turn 120 l/min 500 bar D, C 3/4"G 0.8 kg
A040601.18.00 100-160 bar 150 bar ~30 bar/turn 120 l/min 500 bar D, C 3/4"G 0.8 kg
Pag. 04.01.04A

Valvola di sequenza compensata


Pressure compensated sequence valve

D C

E2

L
E1

CURVE CARATTERISTICHE
p (bar)

E
PERFORMANCE CURVES
10
PRESSIONE / PRESSURE -

8
C
6 Non svitare oltre Lmax
C Do not unscrew more than Lmax
4 D
D C
2

0
20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

Corpo in alluminio/Aluminium body

A040403.01.00 ~112.5 ~113 41.8 HEX36 HEX36 HEX34


A040603.01.00 ~124.5 ~126 41.8 HEX36 HEX36 HEX34
COD. L Lmax F E E1 E2

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max
Pressure Standard Pressure Max
Ordering Code Range Setting Increase Max Flow Pressure Port Size Weight

A040403.01.00 50-150 bar 65 bar ~50 bar/turn 60 l/min 400 bar D, C 1/2"G 0.82 kg

A040603.01.00 50-150 bar 100 bar ~50 bar/turn 120 l/min 400 bar D, C 3/4"G 0.82 kg
Pag. 04.02.01

Valvola di sequenza in linea


Sequence valve

L2
C

L
D

L1
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

4
PRESSIONE / PRESSURE -

3
C C
2

D D
1

HEX 24
HEX 30
C
0
10 20 30 40

PORTATA / FLOW - Q (l/min)

91.5 83 7.5
L L1 L2

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve with adjustable


con taratura regolabile. setting. Available with two
Disponibile con due dierenti dierent outlet ports.
attacchi d'estremit.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A040251.01.00 50-140 bar 60 bar 26 bar/turn 20 l/min 500 bar 1/4"G 0.35 kg
A040251.02.00 15-80 bar 30 bar 14 bar/turn 20 l/min 500 bar 1/4"G 0.35 kg
A040351.01.00 50-140 bar 140 bar 26 bar/turn 40 l/min 500 bar 3/8"G 0.33 kg
A040351.02.00 15-80 bar 40 bar 14 bar/turn 40 l/min 500 bar 3/8"G 0.33 kg
Pag. 04.02.01A

Valvola di sequenza in linea


Sequence valve

L1

L
L2
D

CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

4
PRESSIONE / PRESSURE -

3
C
2 C
D
1 D
C

HEX 24
HEX 21
0
10 20 30 40

PORTATA / FLOW - Q (l/min)

A040351.12.00 91.5 36 20
COD. L L1 L2

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve


con taratura regolabile. with adjustable setting.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A040351.12.00 15-45 bar 40 bar 16 bar/turn 40 l/min 500 bar 3/8"G 0.3 kg
Pag. 04.02.01B

Valvola di sequenza in linea


Sequence valve

C D
REVOLVING
CONNECTOR

L4

L3

L1
HEX21

L
L2
D

CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

4
PRESSIONE / PRESSURE -

3
C
2 C

1 D D
C
0
10 20 30 40
HEX 24
PORTATA / FLOW - Q (l/min)

A040351.15.00 70.5 37 8 34.5 18


COD. L L1 L2 L3 L4

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve


con taratura regolabile. with adjustable setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
C 3/8"G
A040351.15.00 80-110 bar 100 bar 40 bar/turn 40 l/min 500 bar 0.35 kg
D M20x1.5
Pag. 04.02.01C

Valvola di sequenza
Sequence valve

26
C
D

HEX 24
D

96
CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

4
PRESSIONE / PRESSURE -

2 C HEX 24

1 D
D
C C
0
10 20 30 40

PORTATA / FLOW - Q (l/min)

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve


con taratura regolabile. with adjustable setting.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A040351.08.00 30-140 bar 30 bar 60 bar/turn 40 l/min 500 bar 3/8"G 0.28 kg
A040351.08.01 30-140 bar 120 bar 60 bar/turn 40 l/min 500 bar 3/8"G 0.28 kg
A040351.08.02 30-140 bar 50 bar 60 bar/turn 40 l/min 500 bar 3/8"G 0.28 kg
Pag. 04.02.02

Valvola di sequenza in linea


Sequence valve

D
C

E1

L1
L4

L2
D

L3
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
10
C
PRESSIONE / PRESSURE -

8
6 C
4
D
D
2

E2
G

C
0
20 40 60 80 100 120

PORTATA / FLOW - Q (l/min)

111 102 48 15 42 HEX36 HEX36


L1 L2 L3 L4 G E1 E2

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequence valve


con taratura regolabile. with adjustable setting.
Disponibile con due dierenti Available with two dierent
attacchi d'estremit. outlet ports.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A040451.21.00 50-140 bar 50 bar 23 bar/turn 60 l/min 500 bar 1/2"G 0.95 kg
A040451.22.00 20-50 bar 20 bar 12 bar/turn 60 l/min 500 bar 1/2"G 0.95 kg
A040451.22.01 20-50 bar 50 bar 12 bar/turn 60 l/min 500 bar 1/2"G 0.95 kg
Pag. 04.02.03

Valvola di sequenza
Sequence valve

D C

L
E1

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES F

200 10
0 bar)
160
D C (45-12 D
8
120 6
C
80 4
40 D C (20-40 bar) 2
0 0
10 20 30 40 60 70 80

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A040451.03.00 124 34.5 HEX30 HEX30
A040451.04.00 124 34.5 HEX30 HEX30
COD. L F E E1

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max
Pressure Standard Pressure Max
Ordering Code Range Setting Increase Max Flow Port Size Weight
Pressure
A040451.03.00 20-40 bar 20 bar ~16 bar/turn 80 l/min 350 bar D-C 1/2"G 0.6 kg
A040451.04.00 45-120 bar 120 bar ~47 bar/turn 80 l/min 350 bar D-C 1/2"G 0.6 kg
Pag. 04.03.02

Valvola di sequenza compensata


Pressure compensated sequence valve

~L1
Sato/Air bleed

D C

D
D

L
C

L3

L4
CURVE CARATTERISTICHE
p (bar)

L2
PERFORMANCE CURVES

20 H
PRESSIONE / PRESSURE -

16
12
C
8 H2 H3
D
D
4 C
S

0 20 40 60 80 100 120

PORTATA / FLOW - Q (l/min)


H1

Corpo in alluminio / Aluminium body

B040602.01.00 90 ~84 22 79 56 40 90 38 10 70 8.5


COD. L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B040602.01.00 50-220 bar 160 bar 90 bar/turn 120 l/min 300 bar 3/4"G 1.25 kg
Pag. 04.03.04

Valvola di sequenza pilotata con otturatore cilindrico


Spool type sequence valve

H3 H4

L2
D

L5

L6
D

L3
L4

L
C
C

HEX17
CURVE CARATTERISTICHE D (n2)

L1
p (bar)

PERFORMANCE CURVES HEX5


400 16
D C
350 14 H2
PRESSIONE / PRESSURE -

300 12
H1
250 10
200 D 8
150 6
C

S
100 4
D C
50 2
0 0
150/0
25 50 75 100 125 25 50 75 100 125 150 H
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


105 ~45.4 12 70 89 8 31 40 80 50 22 23 32 10.5
L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza Sequential valves


con taratura regolabile. with adjustable setting.

Codice Ordinazione Campo di Taratura Portata Pressione Max Dimensione Peso


Taratura Standard Massima Porte

Ordering Code Pressure Range Standard Max Flow Max Pressure Port Size Weight
Setting
B040452.02.00 10-180 bar 50 bar 150 l/min 350 bar 1/2"G 1.1 kg
B040452.03.00 100-350 bar 350 bar 150 l/min 350 bar 1/2"G 1.1 kg
Pag. 04.03.05

Valvola di sequenza in linea


Sequence valve

H3 D (n2)

=
=
HEX5
V1 C1

L1
HEX17

C1

L3
CURVE CARATTERISTICHE
PERFORMANCE CURVES

L
PRESSIONE / PRESSURE - p (bar)
PRESSIONE / PRESSURE - p (bar)

200 4

L4
150 3
(C1-V1)

L2
100 2 V1

50 H1
1
V1 H
0 C1 0
0 10 20 30 40
=
S

PORTATA / FLOW - Q (l/min)


=

H3
H2

Corpo in alluminio / Aluminium body


B040352.02.00 73 ~50 25.5 40 28 30 80 40 62 20 6.5
COD. L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B040352.02.00 50-150 bar 140 bar 25 bar/turn 40 l/min 350 bar 3/8"G 0.7 kg
Pag. 04.03.06

Valvola di sequenza
Sequence valve

HEX19

=
=
P C F HEX5

L2
L
L1
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

H2 H1
180
150 H3 H H4

120
D (n2)
90
60
P
=

30
S
=

0
5 10 15 20 25 30
PORTATA / FLOW - Q (l/min)
F1

Corpo in acciaio / Steel body


A040252.01.00 60 50 5 30 48 38 5 4.5 45.5 34 15.5 5.5
COD. L L1 L2 S H H1 H2 H3 H4 F F1 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Ordinazione Campo di Taratura Portata Pressione Max Dimensione Peso


Taratura Standard Massima Porte

Ordering Code Pressure Range Standard Max Flow Max Pressure Port Size Weight
Setting
A040252.01.00 25-135 bar 50 bar 30 l/min 350 bar 1/4"G 0.7 kg
Pag. 04.03.07

Valvola di sequenza compensata


Pressure compensated sequence valve
H2
H3

BL
BL

S1
D
H H1

HEX17

D C

L2
HEX19

CURVE CARATTERISTICHE

L
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

20
16
12
C
8 D
D
4 C
L1

0
20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

S1
C
H3
H4
Corpo in acciaio / Steel body
A040602.03.00 124 5 43 40 20 80 2 68.5 23 59
COD. L L1 L2 S S1 H H1 H2 H3 H4

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
C, D 3/4"G
A040602.03.00 50-240 bar 100 bar 45 bar/turn 120 l/min 350 bar 2.6 kg
BL 1/4"G
Pag. 04.03.08

Valvola di sequenza pilotata


Pilot operated sequence valve

0.8
H1

L1
V C

L3
0.8

L4
V

L5
C

L2
L
CURVE CARATTERISTICHE
PERFORMANCE CURVES
1/2"G
20
p (bar)

16
12 C D(n.2)
8 V 70
V
4
PRESSIONE / PRESSURE -

C
0 8 16 24 32 40
3/4"G

=
25 S
20 =
15 C
10 V V = =
5 C H
0 15 30 45 60 75 90 105
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B040402.02.00 95 51 64 10 20.5 39.5 35 70 9 10.5
B040602.02.00 110 60 70 10 22 40.5 45 90 10 10.5
COD. L L1 L2 L3 L4 L5 S H H1 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza con taratura Sequence valve with adjustable


regolabile. setting.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per Giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
B040402.02.00 30-150 bar 120 bar 24 bar/turn 40 l/min 220 bar 1/2"G 0.8 kg
B040602.02.00 20-150 bar 120 bar 15 bar/turn 100 l/min 220 bar 3/4"G 1.5 kg
Pag. 04.04.01

Valvola di sequenza a cartuccia


Cartridge sequence valve

3 HEX4

HEX17

2 1
HEX32

83
39,67
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
3
12
36,52
PRESSIONE / PRESSURE -

10
8
6 M36x2

46
4
2
2

0 50 100 150 200 250 1


PORTATA / FLOW - Q (l/min) 31,75

CODICE SEDE CAVITY CODE


HBS.48.M.03A (Pag. 99.05.03)

DESCRIZIONE DESCRIPTION

Valvola di sequenza pilotata Sequence valve pilot operated


con drenaggio esterno with adjustable setting.
e taratura regolabile. The ow from 1 to 2
Il usso da 1 verso 2 bloccato is blocked until you reach
no a quando non viene the selected valve setting,
raggiunta la taratura impostata, indipendent of back-pressure.
indipendente dalla Drain at 3 has to be
contropressione. Il drenaggio connected directly to tank.
in 3 dev'essere collegato
direttamente a scarico.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

200-210 Nm

Codice Ordinazione Campo di Taratura Incremento per Portata Pressione Max Peso
Taratura Standard Giro Massima
Standard Pressure
Ordering Code Pressure Range Setting Increase Max Flow Max Pressure Weight

C044801.02.00 70-280 bar 250 bar 88 bar/turn 240 l/min 350 bar 0.62 kg
Valvole di blocco a sbloccaggio oleodinamico - Pilot operated check valves

Valvole di blocco a
sbloccaggio oleodinamico
Pilot operated check valves

Le valvole di blocco consentono il flusso Check valves are normally used to allow
libero in una direzione e lo bloccano nel- free flow in one direction and to stop
la direzione opposta fino a quando non the fluid in the opposite one, unless a
vengono aperte dalla pressione di pilo- pilot pressure (Ppil) is applied by the
taggio (Ppil) proveniente dallaltro ramo other line of the circuit.
del circuito. They can be used to ensure the static
Possono ad esempio essere utilizzate lock of a load, not for dynamic control or
per assicurare il blocco statico di un ca- for lowering control.
rico, ma non per controllarne la discesa. If used in combination with restrictor
Se utilizzate in combinazione con val- valves, these ones should be preferably
vole strozzatrici, questultime devono fitted between the actuator and the
essere preferibilmente posizionate tra pilot operated check valve, not between
attuatore e valvola e non tra valvola valve and spool valve, so that the back
e distributore, in modo che la contro- pressure generated by the restrictor
pressione creata dalla strozzatura possa operates against the pilot pressure
agire in verso contrario alla pressione di applied to the valve.
pilotaggio.

C1

Pil

V1

Valvola unidirezionale pilotata singola


Single pilot operated check valve
Valvole di blocco a sbloccaggio oleodinamico - Pilot operated check valves

C1 C2

A B

Valvola unidirezionale pilotata doppia


Dual pilot operated check valve

composta da due valvole unidireziona- This valve is composed by two piloted


li pilotate. In figura rappresentato lo check valves.
schema per il comando di un cilindro le In the picture is shown the pattern for
cui bocche sono collegate ad una valvola the control of an actuator which ports
unidirezionale pilotata doppia. In caso are connected to a dual pilot operated
di arresto intermedio del pistone la val- check valve.
vola blocca entrambe le connessioni del In the case of an in-between stop, the
cilindro senza permettere trafilamenti. valve blocks both the connections of the
Il pistone risulta bloccato e non pu es- cylinder preventing any leakages. The
sere spostato in nessun senso anche se piston is then blocked and it cant be
vengono applicate delle forze esterne. moved in any direction even if external
consigliabile utilizzare per questo tipo forces occur.
di valvole un distributore a centro aper- It is recommended to connect these
to, in modo da evitare che rimangano valves to an open centre spool valve, so
delle contropressioni nei condotti fra that to avoid any back pressure remaining
valvola e distributore. La pressione che in the pipes connecting valve and spool
resta intrappolata potrebbe autopilota- valve. The pressure that could remain
re la valvola e far muovere lattuatore. dragged in the pipes could auto pilot the
Nel caso in cui utilizzi un distributore a valve and move the actuator.
centro chiuso per evitare il fenomeno di In the case of a closed centre spool valve,
autopilotaggio possibile avere la valvo- it is possible to have the valve without
la senza o-ring sul pistone di pilotaggio, the o-ring on the pilot piston to avoid
in questo caso le pressioni intrappolate the auto piloting, this way the pressures
si equilibrano, senza influire sullapertu- are balanced, and they do not affect the
ra. Si tenga presente che togliendo lo- opening.
ring si abbassa leggermente il rapporto Note that without the o-ring, the pilot
di pilotaggio. ratio is a bit lower.
Valvole di blocco a sbloccaggio oleodinamico - Pilot operated check valves

Caratteristiche: Features:
Entrambe le tipologie di valvole sono di- Both kinds are available with steel or
sponibili con corpo in acciaio o in allumi- aluminium bodies, for in line installation
nio, per montaggio in linea o flangiabili or flangeable (with o-rings or hollow
(con o-ring o con vite cava ) e con diversi screw) and with several pilot ratios. The
rapporti di pilotaggio. Il rapporto di pi- pilot ratio R is defined by: pilot piston
lotaggio R dato da: area del pistone di area/seal plunger area.
pilotaggio/area sede otturatore.
Il rapporto di pilotaggio deve essere scel- The pilot ratio must be chosen with
to in modo da rispettare la seguente re- respect to the following:
lazione: R*Ppil > Pcil
R*Ppil > Pcil R= pilot ratio
R= rapporto di pilotaggio Ppil =pilot pressure available
Ppil= pressione di pilotaggio disponibile Pcil = max load induced pressure + Ppil*a
Pcil= pressione indotta dal carico + Ppil*a a = Area of the actuator under the pilot
a = area dellattuatore sottoposta alla pressure / Area under the pressure load
pressione di pilotaggio/area sostenta-
mento carico The pilot pressure required to open the
La pressione di pilotaggio richiesta per valve is:
sbloccare la valvola : Ppil= Pcil/ (R-a)
Ppil= Pcil/ (R-a) Example:
Esempio: Pcil =200 R=4,7:1
Pcil=200 R= 4,7:1 Full bore size 100mm, rod size 90mm
Dimensioni cilindro: fondello 100 mm, a= Differential area / full bore area
stelo 90 mm = 1491,5/7850=0,19
a=Area anulare/area fondello Pil =200/4,71-0,19 = 44,35 (see fig.1)
= 1491,5/7850=0,19
Ppil =200//4,7-0,19)=44,35 , (vedi fig.1)

Fig. 1
Valvole di blocco a sbloccaggio oleodinamico - Pilot operated check valves

Nel caso di utilizzo sul lato stelo di un ci- When the valve is fitted on the rod side
lindro,occorre inoltre che il rapporto di pi- of a cylinder, the pilot ratio must be
lotaggio sia notevolmente superiore ad a much higher than a, or the valve can not
altrimenti la valvola non pu essere pilo- be opened and a damage of the cylinder
tata e pu portare al collasso del cilindro. can occur.
Riferito alla fig.2 e al cilindro con le stesse Referring to the previous example (fig.2),
dimensioni risulta a=7850/1491,5=5,26, when the valve is on the rod side we have
in questo caso R-a risulta negativo e la a=7850/1491,5=5,26. R-a is negative,
valvola non riesce mai a pilotarsi. Occor- so the valve can not open. For this
re quindi scegliere una valvola con pilo- application is necessary to choose a pilot
taggio molto pi alto di a, esempio 10:1. ratio higher than a, for example 10:1.

Dalla formula si ricava: Then we will have:


Ppil=Pcil /(R-a ) =200/(10-5,6) = 200/4,4 Ppil= Pcil/(R-a) =200/(10-5,6) = 45,45 bar
= 45,45 bar

90mm

100mm

Fig. 2

Eventuali contropressioni tra valvola e In case of back pressure downstream


distributore agiscono in verso contrario the valve, the pressure operates against
alla pressione di pilotaggio, pertanto la the pilot pressure, so the pilot pressure
pressione necessaria per pilotare la val- requested will be:
vola sar:
Ppil= Pcil/ (R-a)+ Pv1
Ppil= Pcil/ (R-a)+ Pv1 Pv1= back pressure.
Pv1= pressione dinamica dopo la valvola.
Valvole di blocco a sbloccaggio oleodinamico - Pilot operated check valves

Riferito ai dati dellesempio precedente If Pv1=25 bar, referring to the data of the
se Pv1=25 bar, la pressione di pilotaggio previous example, the result would be:
aumenta a Ppil = 44,35+25=69,35 bar Ppil = 44,35+25 =69,35 bar
Se non diversamente indicato a catalogo Without any note, the pilot piston fits the
il pistone di pilotaggio munito di o-ring. o-ring on the external diameter.
La pressione standard di inizio apertura The standard cracking pressure is 0,5 bar.
in flusso libero 0,5 bar. Valori diversi Different values are available upon
sono disponibili a richiesta. request.
Pag. 05.01.01

Valvola di blocco semplice eetto pilotata


Single pilot operated check valve

L1

C1 C2

H3
H1
A B C1 C2

H2
H
CURVE CARATTERISTICHE
PERFORMANCE CURVES
p (bar)

60 RAPPORTO DI
PILOTAGGIO
DIAGRAMMA
A B
PILOT RATIO DIAGRAM L3 L2
40
5:1
C1
PRESSIONE / PRESSURE -

A 7:1 *
20
A D (n2)
C1 10:1
0/30

20 *
C1 A
C1
S

10 A A
A C1
0
C1
4 8 12 16 20/0 4 8 12 16 20

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


70 40 24 28 20 40 16 30 5 5.5
L L1 L2 L3 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050203.01.00 5:1 20 l/min 350 bar 1/4"G 0.45 kg
A050203.02.00 7:1 20 l/min 350 bar 1/4"G 0.45 kg
A050203.03.00 10:1 20 l/min 350 bar 1/4"G 0.45 kg
Pag. 05.01.02

Valvola di blocco semplice eetto pilotata


Single pilot operated check valve

C1 C2

L
C1' L1
L2 L3

H3
A B
C2 C1

CURVE CARATTERISTICHE

H1
PERFORMANCE CURVES D (n2) C1'

H2
3/8"G

H
20
p (bar)

15
A
10
C1
5 C1 B A
PRESSIONE / PRESSURE -

A
0
8 16 24 32 40
L2 L4

PORTATA / FLOW - Q (l/min) L5

1/2"G
20
15
C1
L6

10
A A
5
C1
0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio/Steel body


A050301.01.00 92 87 15 54 34 32 30 50 25 40 5 6.5
A050401.01.00 92 87 15 54 34 32 30 60 30 50 5 6.5
COD. L L1 L2 L3 L4 L5 L6 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050301.01.00 4.7:1 40 l/min 400 bar 3/8"G 0.9 kg
A050401.01.00 5.2:1 60 l/min 400 bar 1/2"G 1 kg
Pag. 05.01.03

Valvola di blocco semplice eetto pilotata


Single pilot operated check valve

L1 L L5
L2 L3
C1 C2

A B

H1
A B

H
C1 C2
CURVE CARATTERISTICHE
PERFORMANCE CURVES
3/8"G
20 RACCORDO SOLO PER 1/2"G
p (bar)

15 FITTING ONLY FOR 1/2"G


A
10
C1
5 C1
PRESSIONE / PRESSURE -

A
0 8 16 24 32 40
PORTATA / FLOW - Q (l/min)

1/2"G
20
E

15
C1
L6

10
L4

A A
5
C1
0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050303.01.00 80 36 20 38 35 - 17.5 50 30 HEX 30
A050403.01.00 95 38.5 38 38 35 25 17.5 50 32 HEX 30
COD. L L1 L2 L3 L4 L5 L6 H H1 E

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050303.01.00 3.4:1 40 l/min 400 bar 3/8"G 0.6 kg
A050403.01.00 3.4:1 60 l/min 400 bar 1/2"G 0.7 kg
Pag. 05.01.04

Valvola di blocco semplice eetto pilotata


Single pilot operated check valve

L
L1 L2

L3
C1 C2 A B

H1

H2
A B

H
C1 C2

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

3/8"G D
PRESSIONE / PRESSURE -

20
15
A
10
C1
=

5 C1
S

A
0 8 16 24 32 40
=

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B050302.10.00 82 35 15 10 35 50 10 37 9
COD. L L1 L2 L3 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1.
al sostentamento di un carico, Suitable to hold a load
non al controllo discesa. not to control a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

B050302.10.00 4.7:1 40 l/min 400 bar 3/8"G 0.38 kg


Pag. 05.02.01

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L
L1

H3
C1 C2

H1
C1 C2

H2
H
A B

CURVE CARATTERISTICHE A B
PERFORMANCE CURVES
L2 L3
p (bar)

RAPPORTO DI DIAGRAMMA
60 PILOTAGGIO
PILOT RATIO DIAGRAM
40
5:1 D (n2)
C1
PRESSIONE / PRESSURE -

A 7:1 *
20
A C1 10:1
0/30
S

20 *
C1 A
C1
10 A
A
A C1
C1
0 4 8 12 16 20/0 4 8 12 16 20

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


80 40 28 24 20 40 16 30 5 5.5
L L1 L2 L3 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

A050253.01.00 5:1 20 l/min 350 bar 1/4"G 0.45 kg


A050253.02.00 7:1 20 l/min 350 bar 1/4"G 0.45 kg
A050253.03.00 10:1 20 l/min 350 bar 1/4"G 0.45 kg
Pag. 05.02.02

Valvola di blocco doppia


Dual check valves

L
L1
L2 L3
C1 C2

H3
C1 C2
C1' C2'

H1
H2
H
C1' C2'
A B
p (bar)

CURVE CARATTERISTICHE
A B
PERFORMANCE CURVES L4 L5
L6
PRESSIONE / PRESSURE -

20
15 A
10 C1
C1 D (n2)
5
A
0
5 10 15 20 25 30 40
L7

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050351.01.00 120 110 18 74 38 34 55 30 50 25 40 5 6.5
A050351.02.00 110 100 20 60 33 34 50 30 60 25 40 10 6.5
A050351.03.00 110 100 20 60 33 34 50 30 60 25 40 10 6.5
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di blocco doppia Dual check valves poppet type


con otturatore avente apertura with ON-OFF opening,
ON-OFF con uscite C1 e C2 outlet C1 and C2
laterali o in linea. on the side or in line.

NOTA NOTE

Cod. A050351.03.00 non Code A050351.03.00 doesn't


dispone delle porte C1' e C2'. have ports C1' and C2'.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050351.01.00 4.7:1 40 l/min 400 bar 3/8"G 1.1 kg
A050351.02.00 4.7:1 40 l/min 400 bar 3/8"G 1.2 kg
A050351.03.00 4.7:1 40 l/min 400 bar 3/8"G 1.2 kg
Pag. 05.02.02A

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1
L6 L2
C1 C2

H3
C1 C2

H1
H2

H
A B
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
30 A B
PRESSIONE / PRESSURE -

20 L4 L3
C1 L5
15
A A
10 D (n2)
C1
5
0
=

5 10 15 20 25 30 40
S

PORTATA / FLOW - Q (l/min)


=

*Corpo in alluminio / Aluminium body


A050351.04.00 100 7 19 33 34 50 62 30 60 30 40 10 6.5
A050351.06.00 100 9 19 34 32 50 62 35 60 30 40 10 6.5
B050351.02.00 105 7 21.5 36.5 32 52.5 62 35 60 30 40 10 6.5
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Pressione di Dimensione Peso


Pilotaggio Massima Max inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
A050351.04.00 7.1:1 40 l/min 400 bar 8 bar 3/8"G 1.2 kg
* A050351.06.00 7.1:1 40 l/min 350 bar 8 bar 3/8"G 0.7 kg
* B050351.02.00 7.1:1 30 l/min 350 bar 4.5 bar 3/8"G 0.7 kg
Pag. 05.02.02F

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L
L1
C1 C2 L2 L3

H3
C1 C2
C1' C2'

H1
C1' C2'

H
A B

CURVE CARATTERISTICHE H2
p (bar)

PERFORMANCE CURVES A B
L4 L5
1/2"G L6
PRESSIONE / PRESSURE -

20
D (n2)
15
C1
10
A A
5
C1
L7

0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050451.01.00 120 110 18 74 38 34 55 30 60 30 50 5 6.5
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050451.01.00 5.2:1 60 l/min 400 bar 1/2"G 1.3 kg
Pag. 05.02.02G

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L6 L L6
C1 C2 L1
L3 L2

C1 C2

A B

H2
H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
30 H1

H3
25
PRESSIONE / PRESSURE -

20 C1 A B
15 A L5 L4
10 D (n2)
A
5
C1
=

0 10 20 30 40 50 60
S

PORTATA / FLOW - Q (l/min)


=

* Corpo in alluminio / Aluminium body


A050451.05.00 105 52.5 74 15.5 47 29 7 70 35 40 15 35 9
A050451.06.00 110 55 69 20.5 34 38 7 70 35 40 15 35 9
A050451.07.00 110 55 69 20.5 34 38 7 70 35 40 15 35 9
A050451.08.00 110 55 69 20.5 34 38 7 70 35 40 15 35 9
COD. L L1 L2 L3 L4 L5 L6 H H1 H2 H3 S D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Pressione di Dimensione Peso


Pilotaggio Massima Max inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
* A050451.05.00 5.2:1 60 l/min 350 bar 4 bar 1/2"G 0.8 kg
A050451.06.00 7:1 60 l/min 400 bar 8 bar 1/2"G 1.8 kg
* A050451.07.00 3.4:1 60 l/min 350 bar 8 bar 1/2"G 0.8 kg
* A050451.08.00 5.2:1 60 l/min 350 bar 8 bar 1/2"G 0.8 kg
Pag. 05.02.02H

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1
L2
C1 C2 L4 L3
C1 C2

H1
H
V1 V2

H2
V1 V2
p (bar)

CURVE CARATTERISTICHE L6 L5
PERFORMANCE CURVES
D (n2)
PRESSIONE / PRESSURE -

25
20
C1
15 V1
V1
10
L7

C1
5
0 5 10 15 20 25 30 35 40

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050351.08.00 100 7 50 66 17 34 33 35 60 40 10 6.5
A050351.09.00 90 9.5 45 50 20 34 28 30 60 40 10 8.5
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Max Pressione di Dimensione Peso


Pilotaggio Massima inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
A050351.08.00 7:1 40 l/min 400 bar 4.5 bar 3/8"G 1.1 kg
A050351.09.00 4:1 40 l/min 350 bar 8 bar 3/8"G 1.1 kg
Pag. 05.02.03

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1

C1 C2 L3 L2

H1
A B

H
C1 C2

CURVE CARATTERISTICHE

6
PERFORMANCE CURVES A B
p (bar)

60 RAPPORTO DI DIAGRAMMA L5 L4
PILOTAGGIO
PILOT RATIO DIAGRAM
40
C1 5:1
PRESSIONE / PRESSURE -

A 7:1
20 *
A C1 10:1
D (n2)
0/30

20 *
C1 A
C1
S

10 A A
A C1
C1
0
4 8 12 16 20/0 4 8 12 16 20

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body

80 33 34 6 36 22 20 40 16 6.5
L L1 L2 L3 L4 L5 S H H1 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050253.10.00 5:1 20 l/min 350 bar 1/4"G 0.55 kg
A050253.11.00 7:1 20 l/min 350 bar 1/4"G 0.55 kg
A050253.12.00 10:1 20 l/min 350 bar 1/4"G 0.55 kg
Pag. 05.02.03A

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1

L3 L2
C1 C2
A B

H2
H1
A B

H
C1 C2

L4 L5
p (bar)

CURVE CARATTERISTICHE HEX30


PERFORMANCE CURVES D (n2)
PRESSIONE / PRESSURE -

30
20
C1
15 A
A
S

10
C1
5
0 5 10 15 20 25 30 40
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050353.03.00 110 38.5 34 38 94 8 35 50 32 8 8.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Max Incremento Dimensione Peso


Pilotaggio Massima per Giro Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Pressure Port Size Weight
Increase
A050353.03.00 3.4:1 40 l/min 400 bar 8 bar 3/8"G 2.1 kg
Pag. 05.02.04

Valvola di blocco doppia


Dual check valves

L1 L L1
L3 L2

H2
C1 C2
A B

H1
C1 C2

H
A B

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES L5 L4
30
PRESSIONE / PRESSURE -

25 HEX30
D (n2)
20 C1
15 A
10
A
5
C1
S

0 10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050453.03.00 110 38.5 34 38 94 8 35 50 32 8 8.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di blocco doppia Dual check valves poppet type


con otturatore avente with ON-OFF opening,
apertura ON-OFF con uscite outlet C1 and C2 in line.
C1 e C2 in linea.

Codice Ordinazione Rapporto di Portata Pressione Max Pressione di Dimensione Peso


Pilotaggio Massima inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
A050453.03.00 3.4:1 60 l/min 400 bar 8 bar 1/2"G 2.1 kg
Pag. 05.02.05

Valvola di blocco doppia pilotata


Dual pilot operated check valve

C1 C2 L2 L1 L2

L3 L4
A B
A B

CURVE CARATTERISTICHE
PERFORMANCE CURVES

H
3/8"G
20 C1 C2
15
H1
A
10
C1
p (bar)

5 C1
A
0 8 16 24 32 40
PRESSIONE / PRESSURE -

PORTATA / FLOW - Q (l/min) HEX

1/2"G
30
25
20
C1
L5

15
A A
10
5 C1

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

* Corpo in alluminio / Aluminium body


A050353.15.00 63 30.5 18 34 30 40 24
B050353.13.00 71 33 18.5 34 35 50 27
B050353.15.00 63 30.5 18 27 30 40 24
B050453.13.00 71 51 18.5 34 35 50 30
COD. L1 L2 L3 L4 L5 H HEX

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Pressione di Dimensione Peso


Pilotaggio Massima Max inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
A050353.15.00 4.6:1 40 l/min 400 bar 0.5 bar 3/8"G 0.68 kg
* B050353.13.00 4.6:1 40 l/min 350 bar 0.5 bar 3/8"G 0.5 kg
* B050353.15.00 4:1 40 l/min 350 bar 0.5 bar 3/8"G 0.4 kg
* B050453.13.00 4:1 60 l/min 350 bar 3 bar 1/2"G 0.6 kg
Pag. 05.02.06

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1
L3 L2

C1 C2 V1 V2

V1 V2 H C1 C2

Y
H1

Y
H2
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES = =
PRESSIONE / PRESSURE -

20
15
V1 C1
10 HEX22 D
C1 V1
5

0 6 12 18 24 30

PORTATA / FLOW - Q (l/min)


S

Corpo in acciaio / Steel body


A050353.16.00 63 30.6 30 16.5 30 40 25 13 6.5 FOR PIPE 12
COD. L L1 L2 L3 S H H1 H2 D Y

DESCRIZIONE DESCRIPTION

Permette il usso libero da A The valve allows free ow from


verso C1 e da B verso C2, mentre A to C1 and from B to C2,
nelle direzioni inverse il usso whereas in the opposite
pilotato. Idonea al directions the ow is piloted.
sostentamento di un carico, Suitable to hold a load not
non al controllo discesa. to control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Max Pressione di Dimensione Peso


Pilotaggio Massima inizio apertura Porte

Ordering Code Pilot Ratio Max Flow Max Pressure Cracking Port Size Weight
Pressure
A050353.16.00 4:1 30 l/min 230 bar 4.5 bar 3/8"G 0.6 kg
Pag. 05.03.01

Valvola di blocco semplice pilotata destra (con rubinetto)


Single pilot operated check valve with manual shut-o right

L
L1 L2 L3

H5
C1 C2 D
A B

H4
CHIUSO
CLOSED

H1
A B

H2
C1 C2
CURVE CARATTERISTICHE

H
PERFORMANCE CURVES

H3
3/8"G L6
20
p (bar)

15 APERTO
A
OPEN
10 C1
5 C1
PRESSIONE / PRESSURE -

A
0 8 16 24 32 40 Foro D solo sul cod. A050404.03.00
PORTATA / FLOW - Q (l/min) D hole only on cod. A050404.03.00

1/2"G
12
10
L4

A
8
6 C1
C1
4
A
2
L5

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050304.01.00 82 32 35 15 30 52 - 108 50 27 12 12 - M8 -
A050404.03.00 110 38 35 37 30 52 55 108 60 30 15 15 10 M8 8.5
COD. L L1 L2 L3 L4 L5 L6 H H1 H2 H3 H4 H5 M D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050304.01.00 4.7:1 40 l/min 400 bar 3/8"G 0.9 kg
A050404.03.00 5.2:1 60 l/min 400 bar 1/2"G 1.4 kg
Pag. 05.03.02

Valvola di blocco semplice pilotata sinistra (con rubinetto)


Single pilot operated check valve with manual shut-o left

L
L3 L2 L1
D

H5
C1 C2 B A

H4
CHIUSO
CLOSED

M
H1
A B

H2
CURVE CARATTERISTICHE C2 C1

H3
H
PERFORMANCE CURVES
3/8"G L6
20
p (bar)

15 A
10
C1
5 C1
A APERTO
PRESSIONE / PRESSURE -

0 8 16 24 32 40 OPEN
PORTATA / FLOW - Q (l/min)
Foro D solo sul cod. A050404.03.00
1/2"G D hole only on cod. A050404.03.00
12
10
8 A
C1
L4

6
C1
4
A
2
0 10 20 30 40 50 60
L5

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050304.02.00 82 32 35 15 30 52 - 108 50 27 12 12 - M8 -
A050404.04.00 110 38 35 37 30 52 55 108 60 30 15 15 10 M8 8.5
COD. L L1 L2 L3 L4 L5 L6 H H1 H2 H3 H4 H5 M D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight
A050304.02.00 4.7:1 40 l/min 400 bar 3/8"G 0.9 kg
A050404.04.00 5.2:1 60 l/min 400 bar 1/2"G 1.4 kg
Pag. 05.03.03

Valvola di blocco semplice pilotata destra (con rubinetto)


Single pilot operated check valve with manual shut-o right

L
L1 L2

C1 C2 L3

A B

H4
CHIUSO
CLOSED
A B

H1
C1 C2

H2
H3
H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
APERTO
20
PRESSIONE / PRESSURE -

OPEN
15
A
10
C1 C1
5
A L4
0 8 16 24 32 40

PORTATA / FLOW - Q (l/min) D


L5

Corpo in alluminio / Aluminium body


B050304.05.00 82 32 35 10 35 51 101 50 28 12 10 9
COD. L L1 L2 L3 L4 L5 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. from A to C1. Suitable
Idonea al sostentamento di un to hold a load not to
carico, non al controllo discesa. control a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

B050304.05.00 4.7:1 40 l/min 300 bar 3/8"G 0.4 kg


Pag. 05.03.04

Valvola di blocco semplice pilotata sinistra (con rubinetto)


Single pilot operated check valve with manual shut-o left

L
L2 L1
L3
C1 C2

H4
CHIUSO B A
CLOSED

H1
C2 C1

H2
A B

H3

H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES APERTO
OPEN
PRESSIONE / PRESSURE -

20
15
A
10
C1
L4

5 C1
A
0
8 16 24 32 40 D

PORTATA / FLOW - Q (l/min)


L5

Corpo in alluminio / Aluminium body


B050304.06.00 82 35 15 10 35 51 101 50 28 13 10 9
COD. L L1 L2 L3 L4 L5 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un carico, to hold a load not to control
non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Pressione Max Dimensione Porte Peso


Pilotaggio Massima

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

B050304.06.00 4.7:1 40 l/min 300 bar 3/8"G 0.4 kg


Pag. 05.04.01

Valvola di blocco semplice pilotata destra (con rubinetto) angiata con bullone
Single pilot operated fangeable check valve with manual shut-o right

L1 L
L2 L3 L4
L5

A B
C1 C2 CHIUSO
CLOSED

H1
H4
C2

H2

H
A B

H3
CURVE CARATTERISTICHE APERTO
p (bar)

PERFORMANCE CURVES OPEN

3/8"G
20 S2
PRESSIONE / PRESSURE -

15 A S3
10
C1
S

C1
5
A
0
5 10 15 20 25 30 35 40
S1

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050302.01.00 90 5 40 35 15 16.5 30 52 15 3 108 50 27 12 19
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

A050302.01.00 4.7:1 40 l/min 400 bar 3/8"G 1 kg


Pag. 05.04.02

Valvola di blocco semplice pilotata sinistra (con rubinetto) angiata con bullone
Single pilot operatd fangeable check valve with manual shut-o left

L L4
L1 L2 L3

L5
B A
CHIUSO
C1 C2 CLOSED

H4
H2
C1

H3
H1
A B

APERTO
OPEN
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
C2

S2
20
PRESSIONE / PRESSURE -

S3
S
15
A
10
C1
5 C1
A
0
S1

5 10 15 20 25 30 35 40

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050302.02.00 90 15 35 40 5 16.5 30 52 15 3 50 108 27 12 19
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

A050302.02.00 4.7:1 40 l/min 400 bar 3/8"G 1 kg


Pag. 05.04.03

Valvola di blocco semplice pilotata angiata con bullone


Single pilot operated fangeable check valve

L1 L

L2 L3 L4
C1 C2
A B

A B

H
H2
p (bar)

C2
CURVE CARATTERISTICHE
PERFORMANCE CURVES

H1
20
PRESSIONE / PRESSURE -

15
A
10

S3
C1 C1 S2
5
A
0
S1

5 10 15 20 25 30 35 40
S

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


A050302.09.00 90 5 40 35 15 30 53 15 3 50 12 19
COD. L L1 L2 L3 L4 S S1 S2 S3 H H1 H2

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Rapporto di
Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Max Flow Max Pressure Port Size Weight

A050302.09.00 4.7:1 40 l/min 400 bar 3/8"G 1 kg


Pag. 05.04.04

Valvola di blocco semplice pilotata angiabile


Single pilot operated angeable check valve

L1 L

C1 C2 L2 L3 S
B

H1
C1

=
A B C2
H2

H
=
p (bar)

D (n.4)
CURVE CARATTERISTICHE
L4 A
PERFORMANCE CURVES L5 L6 O-RING
PRESSIONE / PRESSURE -

20
15 A
10 C1
5 C1
A
0 5 10 15 20 25 30 35 40

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A050305.02.00 77.5 7 12 35 16 31 32 34.5 60 30 40 6.5 OR 3037 9.19x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 D O-RING

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable
al sostentamento di un to hold a load not to control
carico, non al controllo discesa. a load lowering.

Codice Ordinazione Rapporto di Portata Pressione di Pressione Dimensione Porte Peso


Pilotaggio Massima inizio apertura Max

Ordering Code Pilot Ratio Max Flow Cracking Max Port Size Weight
Pressure Pressure
A, B, C2 3/8"G
A050305.02.00 4.7:1 40 l/min 8 bar 400 bar 1.1 kg
C1 6
Pag. 05.04.05

Valvola di blocco semplice pilotata con bullone


Single pilot operated check valve with hollow screw

L1 L
C1
L2
S1 S
L3 L4
S2
V1 Pil
Pil

V1

H
C1
H1
p (bar)

D
CURVE CARATTERISTICHE
PERFORMANCE CURVES
H2
PRESSIONE / PRESSURE -

20
15 53
A
10
C1 C1
5
A
0 5 10 15 20 25 30 35 40
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


80 5 54 30 14 30 15 3 53 70 22 18 M16x1.5
L L1 L2 L3 L4 S S1 S2 S3 H H1 H2 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1. Idonea from A to C1. Suitable to hold
al sostentamento di un carico, a load not to control
non al controllo discesa. a load lowering. B050310.03.00
Le versioni B050310.03.00 and B050310.04.00 versions
e B050310.04.00 non hanno do not have the o-ring seal
la guarnizione sul pistone on the piston piloting.
di pilotaggio.

Codice Ordinazione Rapporto di Portata Pressione d'inizio Pressione Max Dimensione Peso
Pilotaggio Massima apertura Porte

Ordering Code Pilot Ratio Max Flow Cracking Pressure Max Pressure Port Size Weight

B050310.01.00 4.7:1 40 l/min 0.5 bar 400 bar 3/8"G 0.5 kg


B050310.02.00 4.7:1 40 l/min 7 bar 400 bar 3/8"G 0.5 kg
B050310.03.00 4.7:1 40 l/min 0.5 bar 400 bar 3/8"G 0.5 kg
B050310.04.00 4.7:1 40 l/min 7 bar 400 bar 3/8"G 0.5 kg
Pag. 05.04.10

Valvola di blocco doppia pilotata con bullone


Dual pilot operated check valve with hollow screw

HEX24
L3

C1

=
=
C1 C2

S3 S1 S2
L1
V1 V2

D
C2
F
F1
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE

F2
PERFORMANCE CURVES
30 = =
20 L2 L L2
C1 S
15 V1
10 V1
5 C1
0 V1 V2
5 10 15 20 25 30

=
PORTATA / FLOW - Q (l/min)

=
H1 H

Corpo in alluminio / Aluminium body


B050357.02.00 100 85 11.5 16 30 33.2 8 12 33 32 60 47 28 3/8"G
COD. L L1 L2 L3 S S1 S2 S3 H H1 F F1 F2 D

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow from


da V1 verso C1. Idonea V1 to C1. Suitable to hold a load
al sostentamento di un carico, not to control a load lowering.
non al controllo discesa.

Codice Ordinazione Rapporto di Pressione di Portata Pressione Max Dimensione Peso


Pilotaggio Inizio Apertura Massima Porte
Ordering Code Pilot Ratio Cracking Max Pressure Port Size Weight
Pressure Max Flow
B050357.02.00 4.7:1 4.5 bar 30 l/min 350 bar 3/8"G 0.7 kg
Pag. 05.06.01

Valvola di blocco doppia pilotata


Dual pilot operated check valve

C1 C2
L1 L L1
L3 L6 L6

=
C1 C2

40
H
A B

=
=
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES L2 A 32 B
20 L4 L5
PRESSIONE / PRESSURE -

15 OR 3043 10.77X2.62
16
A
10 6,5
C1 C1
5
A
=

0
34

5 10 15 20 25 30 35 40
=

PORTATA / FLOW - Q (l/min)


D (n.6)

Corpo in alluminio / Aluminium body


A050352.01.00 101 5 34.5 15.5 18.5 64 35 59 6.5
B050352.02.00 101 7 34.5 15.5 18.5 64 35 59 6.5
B050352.03.00 101 5 34.5 15.5 18.5 64 35 59 6.5
B050352.04.00 101 7 34.5 15.5 18.5 64 35 59 6.5
B050352.05.00 96 11 32 13 17 62 35 59 6.5
B050352.06.00 102 6 35 11 18.5 65 40 70 8.5
COD. L L1 L2 L3 L4 L5 L6 H D

DESCRIZIONE DESCRIPTION

Valvola di blocco doppia Flangeable dual check


angiabile con otturatore valves poppet type with
avente apertura ON-OFF. ON-OFF opening.
Le versioni B050352.03.00 Versions B050352.03.00
e B050352.04.00 non hanno and B050352.04.00
la guarnizione sul pistone have not the seal
di pilotaggio. on the piloting piston.

Codice Ordinazione Rapporto di Portata Pressione di inizio Pressione Dimensione Peso


Pilotaggio Massima apertura Max Porte

Ordering Code Pilot Ratio Max Flow Cracking Pressure Max Pressure Port Size Weight
A050352.01.00 7.1:1 40 l/min 1.5 bar 350 bar 3/8"G 0.6 kg
B050352.02.00 7.1:1 40 l/min 8 bar 350 bar 3/8"G 0.6 kg
B050352.03.00 7.1:1 40 l/min 1.5 bar 350 bar 3/8"G 0.6 kg
B050352.04.00 7.1:1 40 l/min 8 bar 350 bar 3/8"G 0.6 kg
B050352.05.00 7.1:1 40 l/min 8 bar 350 bar 3/8"G 0.6 kg
B050352.06.00 4.7:1 40 l/min 8 bar 350 bar 3/8"G 0.6 kg
Pag. 05.06.02

Valvola di blocco doppia pilotata angiabile


Flangeable dual pilot operated check valve

L1 L L1
L2 L3
A B
C1 C2

H1

=
A B

H2
H
C1 C2

=
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
L4 L4
L6
25 L5 L5
PRESSIONE / PRESSURE -

20 C1

15 A

10
S

A
5
C1
0 10 20 30 40 50 60 F
D (n.6)
F1
PORTATA / FLOW - Q (l/min) O-RING F2

* Corpo in alluminio / Aluminium body


105 7 35.5 34 32.5 40 12.5 34 70 35 40 9.5 14.3 20.5 8.5 O-RING 3062 15.54x2.62
L L1 L2 L3 L4 L5 L6 S H H1 H2 F F1 F2 D O-RING

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da A verso C1 e da B verso C2. from A to C1 and from B to C2.
Idonea al sostentamento di un Suitable to hold a load not to
carico, non al controllo discesa. control a load lowering.

Codice Ordinazione Rapporto di Portata Pressione di Pressione Dimensione Peso


Pilotaggio Massima inizio apertura Max Porte

Ordering Code Pilot Ratio Max Flow Cracking Pressure Max Port Size Weight
Pressure
A050452.01.00 3.4:1 60 l/min 8 bar 400 bar 1/2"G 1.3 kg
A050452.02.00 7.1:1 60 l/min 8 bar 400 bar 1/2"G 1.3 kg
* B050452.01.00 3.4:1 60 l/min 8 bar 350 bar 1/2"G 0.7 kg
* B050452.02.00 7.1:1 60 l/min 8 bar 350 bar 1/2"G 0.7 kg
* B050452.03.00 5.2:1 60 l/min 8 bar 350 bar 1/2"G 0.7 kg
Pag. 05.06.03

Valvola di blocco doppia pilotata angiabile


Flangeable dual pilot operated check valve

L1 L L1
C1 C2
L2 L3

C2

=
C1

H1
H
A B

=
=
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES A B
L4
30
PRESSIONE / PRESSURE -

L5 L6
20
C1 L7
15 A
10 A
C1
5
S1

0
5 10 15 20 25 30 40
S

PORTATA / FLOW - Q (l/min)


F D (n.4)
O-RING

Corpo in acciaio / Steel body


A050352.03.00 98 8 12 35 16 31 36 83 34.5 16.5 60 40 7 6.5 OR 3043 10.77x2.62
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 F D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco doppia Flangeable dual check valve


angiabile con otturatore poppet type with ON-OFF
avente apertura ON-OFF. opening.

Codice Ordinazione Rapporto di Portata Pressione di inizio Pressione Dimensione Peso


Pilotaggio Massima apertura Max Porte

Ordering Code Pilot Ratio Max Flow Cracking Pressure Max Pressure Port Size Weight
A050352.03.00 7.1:1 40 l/min 3.5 bar 350 bar 3/8"G 1.4 kg
Pag. 05.06.04

Valvola di blocco doppia pilotata


Dual pilot operated check valve

L1 L L1
C4 C2 C1 C3 L2 L3
L4

C2 C1

C4 C3

H3
V2 V1

H2
H1

H4
CURVE CARATTERISTICHE V2 V1
p (bar)

PERFORMANCE CURVES

D
L5 L6

(n
.3
25

)
PRESSIONE / PRESSURE -

20 L7 L8

15 C1
A
10 A
C1
S1

5
S

0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B050351.04.00 100 7 18.25 63.5 50 32 36 10 80 35 14.5 80 32 56 64.5 8 6.5
COD. L L1 L2 L3 L4 L5 L6 L7 L8 S S1 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di blocco doppia Flangeable dual check valve


angiabile con otturatore poppet type with ON-OFF
avente apertura ON-OFF. opening.

Codice Ordinazione Rapporto di Portata Pressione di Pressione Dimensione Peso


Pilotaggio Massima inizio apertura Max Porte

Ordering Code Pilot Ratio Max Flow Cracking Pressure Max Pressure Port Size Weight

B050351.04.00 7:1 30 l/min 4.5 bar 210 bar 3/8"G 1.4 kg


Pag. 05.07.01

Valvola di blocco a cartuccia pilotata in chiusura


Pilot to close cartridge check valve

C
Pil

27,4

HEX 24

22
CURVE CARATTERISTICHE Pil
PERFORMANCE CURVES
PRESSIONE/PRESSURE - p(bar)

70
26,2
15
12 1-14UNF

34
6 C 6,5
3

0 A
20 40 60 80 100

PORTATA/FLOW - Q(l/min) 22,2

CODICE SEDE CAVITY CODE


HBS.95.S.03A (Pag. 99.08.01)

DESCRIZIONE DESCRIPTION

Permette il usso da A verso C The valve allows the ow from


solo quando la pressione sulla A to C only when pressure in Pil
linea di pilotaggio scende sotto line gets lower than 1/R of the
il valore 1/R della pressione pressure in A (unless of the
in A (a meno della cracking cracking pressure). Flow from
pressure). IL usso da C C to A is always stopped.
verso A sempre bloccato.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

60 Nm

Codice Ordinazione Rapporto di Pressione d'inizio Portata Massima Pressione Max Peso
Pilotaggio Apertura

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

A059507.51.00 3:1 5 bar 100 l/min 400 bar 0.2 kg


Pag. 05.08.01

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

Pil HEX 27

11,5
CURVE CARATTERISTICHE M 22x1.5
PERFORMANCE CURVES
PRESSIONE/PRESSURE - p(bar)

15 C
12

48,5
19
9
V V
6
C C
3
V
0
10 20 30 40 50 Pil

PORTATA/FLOW - Q(l/min) 18

CODICE SEDE CAVITY CODE


HBS.39.M.03A (Pag. 99.05.01)

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da V verso C. Idonea al from V to C. Suitable to hold
sostentamento di un carico, a load not to control a load
non al controllo discesa. lowering.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

60 Nm

Codice Ordinazione Rapporto di Pressione d'inizio Portata Massima Pressione Max Peso
Pilotaggio Apertura

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

A053908.01.00 3:1 0.5 bar 50 l/min 350 bar 0.12 kg


Pag. 05.08.02

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

HEX 22

Pil

21,8
V

30
Pil
CURVE CARATTERISTICHE
20,6
PRESSIONE/PRESSURE - p(bar)

PERFORMANCE CURVES
20 M 20x1.5

15

35
10 C V
V V
5
C
0
10 20 30 40 50 60 C

PORTATA/FLOW - Q(l/min) 17,4

CODICE SEDE CAVITY CODE

HBS.38.M.03A (Pag. 99.05.00)

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da V verso C. Idonea from V to C. Suitable
al sostentamento di un carico, to hold a load not to control
non al controllo discesa. a load lowering.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

Codice Ordinazione Rapporto di Pressione d'inizio Portata Massima Pressione Max Peso
Pilotaggio Apertura

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

C052101.01.00 4:1 2 bar 60 l/min 350 bar 0.12 kg


Pag. 05.08.03

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

HEX 24
C

35
27,4

Pil Pil

26,1
V
1-14UNF-2A

35
CURVE CARATTERISTICHE V
PERFORMANCE CURVES
PRESSIONE/PRESSURE - p(bar)

36
30 C
24 22,2
V
18
C C
12

6 V
CODICE SEDE CAVITY CODE
0
30 60 90 120 HBS.95.S.03A (Pag. 99.08.01)

PORTATA/FLOW - Q(l/min)

DESCRIZIONE DESCRIPTION

Permette il usso libero da V The valve allows free ow


verso C. Idonea al sostentamento from V to C. Suitable to hold
di un carico, non al controllo a load not to control
discesa. a load lowering.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

60 Nm

Codice Ordinazione Rapporto di Pressione d'inizio Portata Pressione Max Peso


Pilotaggio Apertura Massima

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

C052201.01.00 4.5:1 2 bar 120 l/min 350 bar 0.25 kg


Pag. 05.08.04

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

C
HEX32

46
Pil

V
Pil
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

30
25
20

45.8
15
10
V
5
0 80 160 240 320

PORTATA/FLOW - Q(l/min) C
M36x2
CODICE SEDE CAVITY CODE
HBS.48.M.03A (Pag. 99.05.03)

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow from V


da V verso C. Idonea to C. Suitable to hold a load
al sostentamento di un carico, not to control a load lowering.
non al controllo discesa.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

210 Nm

Codice Rapporto di Pressione di Inizio Portata Massima Pressione Max Peso


Ordinazione Pilotaggio Apertura
Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

C054801.01.00 3:1 0.3 bar 240 l/min 350 bar 0.5 kg


Pag. 05.08.05

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

C
HEX22

2
9
Pil

V
Pil
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE

39
PERFORMANCE CURVES

20
15
10 C
V V
V
5
C
0 5 10 15 20 25 30
C
PORTATA/FLOW - Q(l/min)
14,27

3/4"-16UNF-2A
CODICE SEDE CAVITY CODE
HBS.93.U.03A (Pag. 99.02.00)

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow from V


da V verso C. Idonea to C. Suitable to hold a load not
al sostentamento di un carico, to control a load lowering.
non al controllo discesa.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

Codice Ordinazione Rapporto di Pressione di Inizio Portata Massima Pressione Max Peso
Pilotaggio Apertura

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

C059301.01.00 3:1 2 bar 30 l/min 350 bar 0.08 kg


Pag. 05.08.06

Valvola di blocco a cartuccia pilotata


Pilot operated check valve cartridge type

C
HEX34
37,5

Pil

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES C

85
20
15

66
10 C
V V V
5
C
0
20 40 60 80

PORTATA/FLOW - Q(l/min)

Pil

CODICE SEDE CAVITY CODE M 33x2

HBS.46.M.03A (Pag. 99.05.02)

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow from V


da V verso C. Idonea al to C. Suitable to hold a load
sostentamento di un carico, not to control a load lowering.
non al controllo discesa.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

160-180 Nm

Codice Ordinazione Rapporto di Pressione di Inizio Portata Massima Pressione Max Peso
Pilotaggio Apertura
Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

C054601.01.00 3:1 5 bar 80 l/min 350 bar 0.36 kg


Pag. 05.09.01

Valvola di blocco pilotata a manicotto


Pilot operated check valve sleeve type

C
60

3/4"G
HEX 46 D

Pil

38
D
Pil

1/4"G
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE/PRESSURE - p (bar)

135
10
8
6 D C
4 D

2 C HEX 46

0 20 40 60 80 100

PORTATA/FLOW - Q(l/min) C
3/4"G
50

DESCRIZIONE DESCRIPTION

Permette il usso libero The valve allows free ow


da D verso C. Idonea from D to C. Suitable to hold
al sostentamento di un carico, a load not to control a load
non al controllo discesa. lowering.

Rapporto di Pressione d'inizio Portata


Codice Ordinazione Pressione Max Peso
Pilotaggio Apertura Massima
Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Weight

A050611.01.00 1:3.1 5 bar 100 l/min 300 bar 1.8 kg


Valvole overcenter - Overcenter valves

Valvole
overcenter
Overcenter valves

Le valvole overcenter (dette anche val- The overcenter valves are employed
vole di bilanciamento) vengono im- to control the stop and the motion of
piegate per controllare il movimento e one direction of an actuator (single
larresto di un attuatore in uno o in en- overcenter valves) or both the directions
trambi i sensi. (dual overcenter valves).

Svolgono le seguenti funzioni: Functions:


- discesa controllata del carico, il quale - load lowering control: the lowering
pu scendere solo se c un segnale di of the load is possible only if there is a
pilotaggio proveniente dallaltra linea: pilot pressure from the other line; this
ci assicura la rialimentazione del cilin- operation ensures the oil supply of the
dro evitando problemi di cavitazione; cylinder preventing cavitation problems;
- limitazione della pressione massima - containing of the pressure at the
del circuito alla pressione di taratura: in setting value, pressure relief for any
tal modo il sistema viene protetto dai pressure peaks caused by shocks or
picchi di pressione dovuti a urti o mano- overloads;
vre brusche o sovraccarico; - arrest of the flow (and of the load)
- arresto sicuro del flusso (e del carico) when the pump is not working or the
quando la pompa ferma o il distributo- directional valve is in neutral position;
re in posizione neutra; - free flow for load lifting, with reduced
- flusso libero per il sollevamento del ca- pressure drops;
rico con ridotte perdite di carico in attra-
versamento.
They consist of a body where are placed:
Costruttivamente sono formate da un - check valve: it allows the flow in only
corpo in cui sono alloggiate: one direction;
- valvola di non ritorno: permette il pas- - pilot piston: it permits to control the
saggio libero in un solo senso; gradual opening of the relief valve;
- pistone di pilotaggio: permette di con- - relief valve: it permits to limit the
trollare lapertura della valvola di massi- maximum pressure in the actuator,
ma gradualmente; it withholds the load and controls its
- Valvola di massima pressione: permette lowering during the opening of the valve
di limitare la pressione massima nellat- by the pilot signal.
tuatore, trattiene il carico e controlla lo
stesso durante lapertura per mezzo del
segnale di pilotaggio.
Valvole overcenter - Overcenter valves

C1 C2 C2 C1

A B V2 V1

Valvola overcenter a semplice effetto Valvola overcenter a doppio effetto


Single overcenter valve Dual overcenter valve

Guida alla scelta della valvola Guide for the valve choice
Informazioni generali General information

Pressione di taratura Setting pressure


Uno dei dati di progetto la pressione in- One of the design data is the load
dotta dal carico massimo. Tale valore per- induced pressure. This value allows to
mette di definire la pressione di taratura define the setting pressure value of the
della valvola. Solitamente necessario valve. Usually is necessary to have the
che la pressione di taratura della valvola setting pressure value 30% higher than
sia superiore del 30% rispetto al valore the maximum load induced pressure, so
del carico massimo, al fine di consentire that the valve can close also when the
la chiusura della valvola anche quando maximum load is applied.
questa sottoposta a tale sollecitazione. Ptr 1.3 Pmax load
Ptr 1.3 Pmax carico Ptr = setting pressure
Ptr = pressione di taratura
Pilot pressure
Pressione di pilotaggio Another key value is the pressure on
Altro valore fondamentale la pressio- the line that controls the lowering of
ne sul ramo di comando discesa. Tale the load. That pressure is used to allow
pressione utilizzata per consentire the valve opening by a signal called pilot
lapertura della valvola mediante un se- pressure. The pilot ratio R is in fact,
gnale detto di pilotaggio. Si definisce in- defined as:
fatti rapporto di pilotaggio R:
Valvole overcenter - Overcenter valves

Ap = Area di pilotaggio Ap = Pilot area


Ar = Area differenziale di tenuta Ar = Differential retaining area
funzione delle grandezze costruttive and is function of the valve geometrical
della valvola. dimensions.
In generale sono disponibili vari rappor- Usually several pilot ratios are available,
ti di pilotaggio R, la cui scelta guidata and the choice depends upon the
dalle seguenti considerazioni: following considerations:

ALTO RAPPORTO DI PILOTAGGIO (R 8:1): HIGH PILOT RATIO (R 8:1):


implica una ridotta pressione di pilotag- it involves a reduced pilot pressure, that
gio, quindi una elevata velocit di mano- means fast motions and energy saving.
vra e risparmio energetico. Tale scelta Such choice is suggested when the load
consigliata quando il carico nelle diverse is kept quite steady during the various
configurazioni previste per la macchina motions.
rimane allincirca costante.
LOW PILOT RATIO (R 4:1):
BASSO RAPPORTO DI PILOTAGGIO (R 4:1): it involves a high pilot pressure and that
comporta unelevata pressione di pilo- ensures a more accurate control of the
taggio e ci permette un controllo pi motion. Such choice is recommended
preciso del movimento. Tale scelta when the load is very inconstant during
consigliabile quando il carico nelle varie the various motions.
configurazioni previste per la macchina
varia molto. If we define:
Pp = pilot pressure
Se individuiamo con: Ptr = setting pressure
Pp= pressione di pilotaggio Pc = load induced pressure
Ptr= pressione di taratura R = pilot ratio
Pc= pressione indotta dal carico
R= rapporto di pilotaggio for the classic hydraulic cylinders, where
per i normali cilindri idraulici, ove la valvo- the overcenter valve controls the piston
la di bilanciamento controlla il lato fondel- side, the following relation is generally
lo, si utilizza la seguente formula pratica utilised for the calculation of the pilot
per il calcolo della pressione di pilotaggio pressure

ESEMPIO:
Pc=200 bar EXAMPLE:
R=4:1 Pc=200 bar
Ptr=350 bar R=4:1
Allora: Ptr=350 bar
Then:
Valvole overcenter - Overcenter valves

Effetto della contropressione Back pressure consequence


Per una corretta installazione neces- For a correct installation is necessary not
sario che non si formi una contropres- to have a static back pressure between
sione statica nella parte di circuito tra la the overcenter valve and the spool
valvola overcenter e il distributore. Tale valve. Such back pressure could have two
contropressione potrebbe portare a due negative consequences:
effetti negativi: a) It operates on the stopper supporting it
a) Agisce sullotturatore nel senso della closure, causing a higher opening pressure
chiusura, provocando cos un aumento needed
della pressione necessaria per lapertura b) It operates against the pilot pressure
b) Si oppone al pilotaggio rendendo ne- causing a higher pilot pressure needed
cessaria una pressione di pilotaggio pi In the cases of an existing back pressure,
elevata HBS recommends to use the proper
Nei casi in cui si preveda la presenza designed overcenter valves that permit
della contropressione, HBS consiglia di to avoid the back pressure effect on the
utilizzare le valvole overcenter apposi- setting pressure value: theovercentre
tamente sviluppate che permettono di valves for closed centre (c.c. overcenter
eliminare leffetto della contropressio- valves).
ne dal valore della pressione di taratura:
si tratta delle cosiddette valvole over- Closed and open center
center per centro chiuso (c.c.). Closed center and open center directional
spool example:
Centro chiuso e centro aperto
Esempio di distributore a centro chiuso
e centro aperto:

A B A B

T T

Distributore centro chiuso Distributore centro aperto


Close center directional spool Open center directional spool

Tipologie costruttive valvole overcenter Technical features of overcenter valves

Valvole overcenter con valvola di non ri- Overcenter valves with separated check
torno separata dalla valvola di massima valve and relief valve series br
pressione serie br The valves with steel/aluminium bodies
Costruite con collettore in acciaio o in are available with different pilot ratio;
alluminio sono disponibili con diversi during the load lifting the oil flows free
rapporti di pilotaggio, non intercambia- through the check valve.
bili. In fase di sollevamento lolio passa During the load lowering any downstream
attraverso una valvola di non ritorno. back pressures operate against the pilot
Durante la discesa del carico eventuali pressure and increase the setting value
contropressioni a valle della valvola si of the relief valve.
Valvole overcenter - Overcenter valves

oppongono al pilotaggio, e innalzano il


valore di taratura della valvola.

C1 C2

A B

Se chiamiamo Psc la pressione dopo la If Psc is the pressure downstream the


valvola, questa ha due effetti: valve, it has two effects:

(A) Aumenta la pressione di taratura del- (A) The pressure setting will be increased
lo stesso valore, che diventa with the same value and becomes
Ptr1 = Ptr +Psc Ptr1 = Ptr +Psc
Ptr1 = pressione di taratura modificata Ptr1 = modified setting pressure
Ptr = taratura iniziale Ptr = setting of the valve
Psc = pressione a valle della valvola Psc = downstream pressure

(B) Aumenta la pressione richiesta per (B) The pilot pressure to open the valve
pilotare la valvola, che diventa becomes
Ppil1 = (Ptr+Psc/ R+a)+Psc Ppil1 =(Ptr+Psc/ R+a)+Psc
a = area dellattuatore sottoposta alla a = area of the actuator under the pilot
pressione di pilotaggio/area sostenta- pressure/Area under the load pressure.
mento carico
High downstream pressure may prevent
Valori elevati di pressioni dopo la valvo- the valve from opening. When connected
la potrebbero impedirne lapertura. In with closed centre spool valve the
caso di distributore a centro chiuso vie- overload function is taken off.
ne inibita la funzione di overload.

Valvole overcenter con valvola di non Overcenter valve with integrated relief
ritorno integrata e coassiale con la and check valve
valvola di massima pressione
They show a very compact shape, with
Presentano una forma compatta, hanno only one sealing point, so they are not
un unico punto di tenuta della pressione affected by contamination in the fluid.
indotta dal carico e sono meno sensibili
allo sporco.
Valvole overcenter - Overcenter valves

Infatti eventuali contaminanti intrappolati In fact, if some dirt is trapped between


sotto gli elementi di tenuta, possono esse- the sealing seat, it can be easily removed
re lavati via facendo una salita del carico. lifting the load.
A causa della particolare forma costrutti-
va degli elementi interni, il loro funziona- Because of the internal elements shape
mento viene maggiormente influenzato and dimensions, their functioning is more
da eventuali pressioni a valle della valvo- affected by the downstream pressure
la rispetto alla versione precedente. compared to the previous type.

Le formule precedenti diventano: The relations are modified as below:


Ptr1 = PTr + Psc (R+1) Ptr1 = PTr + Psc (R+1)

Tale effetto tanto pi importante quan- The lower are the pilot ratios, the more
to pi il rapporto di pilotaggio basso. pronounced becomes this effect.
Le valvole overcenter prima descritte These overcenter valves can relief a
possono scaricare un picco di pressio- peak of pressure or protect the circuit
ne o svolgere la funzione di protezione against overloads only if connected
contro sovraccarichi solo se il distribu- with open centre spool valves and if the
tore sottostante a centro aperto e se operator is not applying any pressure
loperatore non crea una pressione sulla from the inlet line.
linea di mandata.

Valvole overcenter compensate Overcenter valves not affected by the


back pressure in the relieving function
In caso di utilizzo di distributori a centro
chiuso, affinch la valvola possa svolge- In combination with closed centre spool
re la funzione di limitare la pressione valves, the valve can activate the relieving
massima dentro lutilizzatore, deve es- function only when compensated to back
sere compensata contro la pressione a pressure and an auxiliary relief valve is
valle. Inoltre sul ramo del distributore fitted downstream the overcenter valve.
deve essere presente una valvola an- The auxiliary relief valve must be set
tishock, tarata ad un valore inferiore below the overcenter valve. The auxiliary
rispetto alla valvola di massima dello- relief valve is required also with open
vercenter. La presenza della valvola au- centre spool valve to avoid the exclusion
siliaria antishock sulla mandata permet- of the relief function adding a back
te lintervento della valvola a limitare la pressure downstream the overcenter
pressione massima anche con distribu- valve.
tore a centro aperto e pressione creata
sulla linea di mandata.
Valvole overcenter - Overcenter valves

LOAD

C1 C2

A B

La pressione sulla linea di mandata in The back pressure in any case operates
ogni caso agisce in contrasto al pilotag- against the pilot pressure as explained
gio come precedentemente descritto. above. So the previous relations become:
Pertanto le formule diventano:
Ptr1 = Ptr
Ptr1 = Ptr Ppli 1 = Ppil+ PSc (R+1/R)
Ppli1 = Ppil+ PSc (R+1/R)

Valvole per argani Winches valves

C3

V2 C2

V1 C1

They are a combination between an


Sono formate da una valvola overcenter overcenter valve for open centre
per centro aperto e da una valvola selet- directional valves and a shuttle valve
trice per comandare lo sblocco del freno to control the opening of the hydraulic
motore. motor brake.
Valvole overcenter - Overcenter valves

La relazione tra le pressioni presenti la The relation between the pressures is


seguente: the following:

Dove: Where:
PT: pressione di taratura PT: setting pressure
PC: pressione indotta dal carico PC: pressure induced by the load
R: rapporto di pilotaggio R: pilot ratio
PP: pressione di pilotaggio PP: pilot pressure
Bisogna inoltre verificare che la pressione It needs to verify that the minimum pilot
di pilotaggio minima sia sufficiente a te- pressure is sufficient to keep open the
nere aperto il freno motore (circa 20 bar): brake:

Se la relazione precedente non viene ri- If the previous relation is not satisfied its
spettata si procede nei possible to:
seguenti modi: - increase the pilot pressure;
- aumento della pressione di taratura; - reduce the pilot ratio.
- diminuzione del rapporto di pilotaggio. In order to avoid that the brake opens for
Per evitare che il freno motore si apra the effect of the
per effetto della back pressure, open centre directional
contropressione si devono impiegare di- valves are needed.
stributori in c.a.

Valvole controllo discesa senza area Lowering valves without differential


differenziale (ad otturatore insensibi- area of the sealing plunger (pressure
le alla pressione) compensated)
Valvole overcenter - Overcenter valves

Sono valvole che controllano la discesa They are used to control the lowering
di un carico con la pressione di pilotag- of a load with the pilot pressure which
gio che funzione solo del precarico depends only from the spring preload
della molla e dellarea del pistone di and the pilot piston area. For these valves
pilotaggio. Non possibile definire un it is not possible to determine a pilot ratio
rapporto di pilotaggio. Sono formate da since the seal plunger have no area under
una valvola unidirezionale coassiale o the load pressure. They consist in a check
meno con lotturatore di tenuta, un pi- valve that can be coaxial with the sealing
stone di pilotaggio e una valvola ausilia- plunger, a pilot piston and an auxiliary
ria di massima pressione, per abbattere relief valve to cut off overload peaks.
eventuali picchi di pressione. La pressio- The pilot pressure requested to open the
ne di pilotaggio richiesta generalmen- valve is normally in the range 5-25 bar,
te compresa nel campo 5-25 bar, a se- according to the spring preload. The max
conda del precarico dato alla molla che lowering speed can be limited with the
tiene in posizione chiusa lotturatore. La regulation of the max pilot pressure.
velocit di discesa del carico deve essere
regolata limitando la pressione massima
sul pilotaggio.

Valvole serie EMM Valves EMM series

Idonee alluso su macchine movimento They are suitable to be used on


terra. excavators machines.
Sono valvole che controllano la discesa They are used to control the lowering of a
di un carico con la pressione di pilotag- load and the pilot pressure depends only
gio che funzione solo del precarico del- from the spring preload and the piston
la molla e dellarea del pistone di pilo- area since they have no differential area.
taggio (valvole senza area differenziale). The pilot pressure is normally achieved
La pressione di pilotaggio viene presa simultaneously from the manipulators
dai manipolatori di comando distributo- pressure to drive the main spool valve.
re. La valvola e i manipolatori vengono For these valve it is not possible to
comandati in simultanea. determine a pilot ratio.
Non possibile definire un rapporto di They consist in a check valve that can be
pilotaggio. coaxial with the sealing plunger, a pilot
Sono formate da una valvola unidirezio- piston and an auxiliary relief valve to cut
nale coassiale o meno con lotturatore off overload peaks.
di tenuta, un pistone di pilotaggio e una The sealing plunger is piloted by the
valvola ausiliaria di massima pressione, pressure downloaded by the relief valve.
utilizzate per abbattere eventuali picchi The valve is not affected by any back
di pressione. pressure in the V2 line. In case of damage
Lo scarico di questultima valvola va a of the manipulators, the lowering of
pilotare lapertura dellotturatore. La the load can be performed manually,
valvola insensibile a eventuali contro- operating on the proper manual pilot
pressioni sulla linea V2. In caso di guasto screw.
dei manipolatori, la discesa del carico pu Line T must be connected to the reservoir
essere fatta manualmente, operando and without back pressure.
sullapposita vite di pilotaggio manuale.
Il condotto T deve essere messo a scarico
separatamente e senza contropressione.
Valvole overcenter - Overcenter valves

Valvole serie emm flangiabili Valve emm series flangeable


(pag. 06.15) (pag. 06.15)

Sono simili, a livello funzionale, alle These valves are functionally similar to
valvole precedenti e sono sagomate in the previous ones, and they are shaped
modo da facilitarne il montaggio sui ci- for an easier assembling on the lifting
lindri di sollevamento degli escavatori. cylinders of the escavators. The valves
Le valvole hanno un attacco passante E, have a through port E, with a restriction,
munito di strozzatura, per il collegamen- for the parallel connection of the two
to in parallelo dei due cilindri di solleva- lifting cylinders. This port can be used
mento, che pu anche essere usato come as an emergency lowering in case of
discesa demergenza in caso di avaria dei damage of the manipulators or of the
manipolatori o della relativa pompa. relative pump.
Se opportunamente tarate permettono If properly set the valve can meet the
di soddisfare i requisiti della EN 474 (ISO EN 474 (ISO 8643) regulation, when the
8643) nel caso lescavatore sia utilizzato excavators is used also for the lifting and
anche per il sollevamento e posa di carichi. the lowering of loads.

Valvole overcenter rigenerative Regenerative valves

Nei circuiti rigenerativi si invia il liquido In the regenerative circuits, the fluid in
presente nella camera anulare alla came- the rod side of the cylinder is sent to the
ra in spinta, rigenerando quindi il fluido piston side of the cylinder, regenerating
destinato, in normali applicazioni, al ser- the fluid usually destined to the
batoio. In questo modo, nella camera in reservoir. This way, in the piston side, the
spinta, alla portata erogata dalla pompa flow arriving from the rod side is added
si aggiunge quella in arrivo dalla came- to the flow arriving from the pump, with
ra opposta, con un notevole incremento a notable increase of the piston speed
della velocit del pistone (fig.1). Questa (fig.1). This solution is utilised to control
soluzione si impiega per controllare ci- cylinders when a lower output stroke
lindri per i quali si desidera avere un tem- time is required without increasing the
po di uscita dello stelo pi breve senza pump flow.
aumentare la portata della pompa.

C2 C1
D

Qrig

M
Qp

V2 V1
Valvole overcenter - Overcenter valves

Qrig = portata totale Qrig = total flow


*Qrig = portata rigenerata *Qrig = regenerative flow
Qp = portata pompa Qp = pump flow
D = diametro fondello D = piston diameter
d = diametro stelo d = rod diameter
= (area anulare del cilindro / area del = (differential area / piston area)
fondello)

Durante la fase rigenerativa, il fluido During the regeneration, the fluid that
passante dalluna allaltra camera riduce passes from a side to the other one
la spinta che pu esercitare il cilindro, reduces the thrust that the cylinder can
questo perch la pressione nelle due apply, because the pressure is the almost
camere uguale. La spinta del cilindro the same in both the chambers, so the
corrisponde quindi alla pressione per la- thrust is given by the pressure operating
rea dello stelo. only on the rod area.
Poich la portata di olio rigenerata Since the regenerative flow is higher
maggiore di quella della pompa mol- than the pump one, is necessary to
to importante determinare preventi- consider *Qrig value as the key value to
vamente il valore di *Qrig in modo da design the proper pipes and connections,
dimensionare correttamente i tubi e i to avoid high pressure drops.
raccordi, al fine di evitare eccessive per- These pressure drops could reach
dite di carico. the setting value of the relief valve
Queste ultime potrebbero far inter- compromising the regeneration benefit.
venire la valvola di massima pressione Because of the same reason it is always
dellimpianto e compromettere il bene- suggested to install the regenerative
ficio della rigenerazione. valve near the cylinder, so that to have
Per la stessa ragione, sempre consi- shorter pipes and lower pressure drops.
gliabile installare la valvola rigenerativa
sempre vicino al cilindro al fine di avere
tubi di collegamento pi corti.
Pag. 06.01.01

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter "BR series"
F L1 L
L3
C1 HEX4
L2
HEX 13
P
C1

H
P
p (bar)

H1
H3
CURVE CARATTERISTICHE A
PERFORMANCE CURVES

H2
PRESSIONE / PRESSURE -

10 L5 L4
8 D (n.2)
6
4 A

S1
C1 C1
2

S
A
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


88 ~50 27.5 45 12 49 30 15 60 26 7 21 8.5
L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from A to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with the
sostentamento del carico pump not running, controlled
con distributore in neutro movement when pilot pressure
o a pompa ferma, controllo is applied, relief function
del movimento di discesa against overpressure
del carico a seguito in the cylinder.
del pilotaggio della valvola
pilotaggio, protezione
da sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione


Ordinazione Taratura Standard per Giro Massima Max Porte Peso
Pilotaggio

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
C1, A 3/8"G
A060300.00.00 4.84:1 100-350 bar 250 bar 125 bar/turn 45 l/min 500 bar 1.2 kg
P 1/4"G
C1, A 3/8"G
A060300.01.00 6.83:1 100-450 bar 250 bar 175 bar/turn 45 l/min 500 bar 1.2 kg
P 1/4"G
C1, A 3/8"G
A060300.02.00 9.49:1 100-450 bar 250 bar 240 bar/turn 45 l/min 500 bar 1.2 kg
P 1/4"G
Pag. 06.01.02

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter "BR series"

F L1 L
L2
C1
L3
L4

P HEX4 C1
HEX13
A

H2

H
P
p (bar)

CURVE CARATTERISTICHE

H1
PERFORMANCE CURVES

10 A
PRESSIONE / PRESSURE -

H3
8 D (n.2)
6
A
4
C1 C1

=
2

S
A
0

=
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


96 ~50 70.5 52.5 30 30 60 20 50 5 6.25
L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as
Collegare allimpianto come shown. The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with
sostentamento del carico spool in neutral position
con distributore in neutro or with the pump not
o a pompa ferma, running, controlled
controllo del movimento movement when pilot
di discesa del carico a seguito pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola relief function against
PIOMBATURA CODE pilotaggio,protezione da overpressure in the cylinder.
916003 sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
100-350 C1, A 1/2"G
A060400.00.00 4.84:1 bar 350 bar 125 bar/turn 60 l/min 500 bar 1.3 kg
P 1/4"G
100-450 C1, A 1/2"G
A060400.01.00 6.83:1 bar 250 bar 175 bar/turn 60 l/min 500 bar 1.3 kg
P 1/4"G
Pag. 06.01.03

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"
F L1 L

L3 L4
C1 X

H1
C1

Pil

=
A Pil

H
X
HEX4

=
HEX13
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES X A
25 L2
L5 D (n.2)
PRESSIONE / PRESSURE -

20
15 A C1
A
10 C1

S
5

0 10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


91 ~42 19 25.6 47.6 51 30 55 7 8.5 1/4"G
91 ~42 19 25.6 47.6 51 30 55 7 8.5 3/8"G
91 ~42 19 25.6 47.6 51 35 65 11 8.5 1/4"G
L L1 L2 L3 L4 L5 S H H1 D X

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
La valvola permette: usso libero The valve allows: free ow
da A verso C1, sostentamento from A to C1, to hold the
del carico con distributore load with spool in neutral
in neutro o a pompa ferma, position or with the pump not
controllo del movimento di discesa running, controlled movement
CODICE ORDINAZIONE SEALING ORDERING del carico a seguito del pilotaggio when pilot pressure is applied,
PIOMBATURA CODE della valvola pilotaggio, protezione relief function against
da sovrapressioni nel cilindro. overpressure in the cylinder.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060261.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 20 l/min 500 bar 1/4"G 1.1 kg
A060261.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.1 kg
A060261.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 20 l/min 500 bar 1/4"G 1.1 kg
A060361.11.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060361.12.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060361.13.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060461.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 1/2"G 1.5 kg
A060461.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 1.5 kg
A060461.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 1.5 kg
Pag. 06.01.03A

Valvola di bilanciamento semplice eetto, serie 140


Single overcenter "140 series"

L1 L
F
L2

C1 L3 L4

H1
C1
P
P

=
A

H
=
HEX4

HEX13 A
L5
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
D (n.2)
25
PRESSIONE / PRESSURE -

20 A
C1

=
15

S
10

=
C1
A
5

0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060261.22.00 84 ~36 50 36 28 23 25 45 7.5 6.5
COD. L L1 L2 L3 L4 L5 S H H1 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from A to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico a seguito overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola
PIOMBATURA CODE pilotaggio, protezione
da sovrapressioni nel cilindro.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060261.22.00 4.1:1 100-350 bar 300 bar 180 bar/turn 30 l/min 500 bar 1/4"G 0.7 kg
Pag. 06.02.01

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter "BR series"

L1 L
F L2
L3
C1 C2
HEX4 C1 C2
HEX13

A B

H1
H
H3
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
A B

H2
10 L4 L5
PRESSIONE / PRESSURE -

8 D (n.2)
6
A
4 C1 C1

L7
2 A

L6
0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060300.20.00 107 ~50 67.5 27.5 49.5 40.5 30 15 60 44 8 26 8.5
A060400.20.00 110 ~50 71 29.5 52.5 40.5 30 15 60 44 8 22 8.25
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be
a centro aperto in neutro. connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from A to C1, to hold the load
usso libero da A verso C1, with spool in neutral position
sostentamento del carico or with the pump not
con distributore in neutro running, controlled movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico a seguito overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola
PIOMBATURA CODE pilotaggio, protezione
916003 da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060300.20.00 4.84:1 100-350 bar 250 bar 125 bar/turn 45 l/min 500 bar 3/8"G 1.4 kg
A060400.20.00 4.84:1 100-350 bar 250 bar 125 bar/turn 60 l/min 500 bar 1/2"G 1.4 kg
Pag. 06.02.02

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"

L6 L
F
L1 L7
C1 C2 L2 L3
S Y Y

H1
C1 C2

A B

=
HEX13

H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

=
HEX13
25
PRESSIONE / PRESSURE -

20 HEX4
A Y S B Y
15 A C1 X
L5
A
10 C1 L4 D (n.2)
5

0 10 20 30 40 50 60

=
L8
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
109 52 32 40 54 19.5 ~42 39 30 55 8 8.5 1/4"G 1/4"G
109 52 32 40 54 19.5 ~42 39 30 55 8 8.5 1/4"G 3/8"G
109 52 32 40 54 19.5 ~42 39 35 65 8 8.5 1/4"G 1/2"G
L L1 L2 L3 L4 L5 L6 L7 L8 H H1 D X Y

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with open
con spole a centro aperto in neutro. centre spools. To be connected
Collegare allimpianto come as shown. The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico
in neutral position or with
con distributore in neutro
the pump not running,
o a pompa ferma, controllo
del movimento di discesa controlled movement when
del carico a seguito del pilotaggio pilot pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING
PIOMBATURA CODE della valvola pilotaggio, protezione relief function against
da sovrapressioni nel cilindro. overpressure in the cylinder.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060261.04.00 2.7:1 80-350 bar 350 bar 85 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060261.05.00 4.3:1 100-350 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060261.06.00 8.8:1 100-350 bar 350 bar 90 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060361.14.00 2.7:1 80-350 bar 350 bar 85 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060361.15.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060361.16.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060461.04.00 2.7:1 80-350 bar 350 bar 85 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060461.05.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060461.06.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
Pag. 06.02.02A

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"

L1 L L2
F L7
L3
C1 C2
L4 L5
2

H2
C1 C2

A B
1

H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES HEX 13
25 A B
HEX4
PRESSIONE / PRESSURE -

L6

H1
20
2
15 A HEX 10
10 C1 C1 D (n.2) HEX3
A
5

=
0 10 20 30 40 50

S
=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


109 ~42 ~10 52 32 40 19.5 91 30 55 24 8 8.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools . To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come da free ow from A to C1,
schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico a seguito overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola
PIOMBATURA CODE pilotaggio, protezione
916003 da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Setting Increase Flow Pressure
1 80-350 bar 1 300 bar 1 85 bar/turn
A060361.07.00 2.7:1 45 l/min 500 bar 3/8"G 1.3 kg
2 200-400 bar 2 250 bar 2 215 bar/turn
1 80-350 bar 1 350 bar 1 135 bar/turn
A060361.08.00 4.3:1 45 l/min 500 bar 3/8"G 1.3 kg
2 200-400 bar 2 300 bar 2 215 bar/turn
1 80-350 bar 1 350 bar 1 90 bar/turn
A060361.09.00 8.8:1 45 l/min 500 bar 3/8"G 1.3 kg
2 200-400 bar 2 300 bar 2 215 bar/turn
Pag. 06.02.02B

Valvola di bilanciamento semplice eetto, serie 165, con valvola paracadute


Single overcenter valve "165 series" with hoseburst valve

F
L
C1 C2 L1 L3 L2
2
X L4 L5

H2
C1 C2
1

=
1
A B

H
=
CURVE CARATTERISTICHE HEX13 A 2 B
p (bar)

PERFORMANCE CURVES

H1
25 HEX4 L6
PRESSIONE / PRESSURE -

20 X
L7
HEX3
15 A
D (n.2)
10 C1 C1
A
5

S1
S
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


109 ~42 ~10 52 32 40 19.5 91 30 15 55 16 8 8.5
L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 H2 D

DESCRIZIONE

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools . To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come da free ow from A to C1,
schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico a seguito overpressure in the cylinder.
del pilotaggio della valvola A hose burst valve
pilotaggio, protezione is tted inside the X port.
CODICE ORDINAZIONE SEALING ORDERING da sovrapressioni nel cilindro.
PIOMBATURA CODE La valvola integra la valvola
paracadute (2) sull'attacco X.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
A, B, C1, C2 3/8"G
A060361.04.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 500 bar 1.4 kg
X 1/4"G
A, B, C1, C2 3/8"G
A060361.05.00 4.3:1 80-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 1.4 kg
X 1/4"G
A, B, C1, C2 3/8"G
A060361.06.00 8.8:1 80-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 1.4 kg
X 1/4"G
Pag. 06.02.03

Valvola di bilanciamento semplice eetto, serie 210


Single overcenter valve "210 series"

F L
L1
M C1 C2
HEX 10 L2 L3
HEX 24

H2
C2 C1

A B

H
H1
p (bar)

CURVE CARATTERISTICHE B M A
PERFORMANCE CURVES L4
HEX 13
25 L5
PRESSIONE / PRESSURE -

20 L6
15 D (n.2)
A
10 C1
C1
S1

5
A
S

0 20 40 60 80 100 120

PORTATA / FLOW - Q (l/min) L7

Corpo in acciaio / Steel body


185 122.5 40 62.5 39 82.5 141 40 20 60 30 10 8.5
L L1 L2 L3 L4 L5 L6 S S1 H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from A to C1, to hold the load
usso libero da A verso C1, with spool in neutral position
sostentamento del carico or with the pump not
con distributore in neutro running, controlled
o a pompa ferma, controllo movement when pilot
del movimento di discesa pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING
PIOMBATURA CODE pilotaggio, protezione
da sovrapressioni nel cilindro.
916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
A, B, C1, C2 1/2"G
A060461.12.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.4 kg
M 1/4"G
A, B, C1, C2 1/2"G
A060461.13.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.4 kg
M 1/4"G
Pag. 06.02.04

Valvola di bilanciamento semplice eetto, serie 210


Single overcenter valve "210 series"

F L
L1
S C1 C2 L2
HEX 13 L3
C2 C1
HEX 10 HEX 24

A B

H
H1
H2
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES B S A
L6 = = L4
25
PRESSIONE / PRESSURE -

L5
20
15 D (n.2)
A
10 C1
C1

=
5 A

S
0 25 50 75 100 125 150

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060661.02.00 190 147 126 83 40 40 40 80 40 20 10.5
A060661.03.00 190 147 126 83 40 40 40 80 40 20 10.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from A to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo del when pilot pressure
movimento di discesa del carico is applied, relief function
a seguito del pilotaggio della against overpressure
CODICE ORDINAZIONE SEALING ORDERING valvola pilotaggio,protezione in the cylinder.
PIOMBATURA CODE da sovrapressioni nel cilindro.
916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, B, C1, C2 3/4"G
A060661.02.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3.3 kg
S 1/4"G
A, B, C1, C2 3/4"G
A060661.03.00 8:1 150-350 bar 350 bar 82 bar/turn 150 l/min 500 bar 3.3 kg
S 1/4"G
Pag. 06.02.04A
Valvola di bilanciamento semplice eetto serie BP
con valvola limitatrice di pressione
Single overcenter valve "BP series" with pressure relief
C1

S2
C2

=
0.5 2

=
L2
L9

S1
1 1
L8
L7

V2 V1 T 2
)
CURVE CARATTERISTICHE D (n.2
PERFORMANCE CURVES
25 HEX5

H2
H
p (bar)

20

H3
15 V2
10 C2
H4
C2 HEX17

H1
PRESSIONE / PRESSURE -

5
V2
0 L6
25 50 75 100
3/4"G PORTATA / FLOW - Q (l/min)
HEX5
25

=
20

S
V2 C2

=
15
10 C2 V2 L5
5 L4
HEX17
0 L3
10 20 30 40 50 60
L1 L L2
1/2"G PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060466.17.00 120 ~63.4 16.5 100 56 20 83 100 48 20 40 17.5 22.5 120 25 70 83 44 8.5
A060666.06.00 130 ~63.4 16 110 56 20 91 110 58 25 40 26 20 120 25.5 60 83 46 8.5
COD. L L1 L2 L3 L4 L5 L6 L7 L8 L9 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with open
con spole a centro aperto in neutro. centre spools. To be connected
Collegare allimpianto come da as shown. The valve allows:
schema. La valvola permette: usso free ow from V2 to C2, to hold
libero da V2 verso C2, the load with spool in neutral
sostentamento del carico con position or with the pump not
distributore in neutro o a pompa running, controlled lowering
ferma, controllo del movimento movement when pilot pressure
di discesa del carico tramite il is applied, relief function against
pilotaggio della valvola, protezione overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING da sovrappressioni nel cilindro. The lowering control valve inside,
PIOMBATURA CODE La valvola di controllo discesa is in cartridge style .
916005 a cartuccia.

Codice Rapportodi Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Setting Increase Flow Pressure
10:1 1 100-350 bar 210 bar 93 bar/turn C1,C2
V1,V2 1/2"G
A060466.17.00 60 l/min 400 bar 4.25 kg
- 2 135-320 bar 280 bar 75 bar/turn T 1/2"G
L2 1/4"G
10:1 1 100-350 bar 210 bar 155 bar/turn C1,C2 3/4"G
A060666.06.00 100 l/min 400 bar V1,V2 4.4 kg
- 2 135-320 bar 280 bar 75 bar/turn T 1/2"G
L2 1/4"G
Pag. 06.02.05

Valvola di bilanciamento semplice eetto angiabile, serie 210 CC


Flangeable single overcenter valve "210 CC series"

F
L
L1
S C2 C1
HEX 13 L2
L3
HEX 10 C1 V2
SFIATO/
AIR BLEED
V2 V1

=
C2
H3

H
=

H1
p (bar)

CURVE CARATTERISTICHE

H2
PERFORMANCE CURVES V1 S V2
25 = = L4
PRESSIONE / PRESSURE -

L6
20 L5 HEX 24
15 D (n.4)
A
10
C1 C1
5
A

S1
0
25 50 75 100 125 150

S
PORTATA / FLOW - Q (l/min)

F O-RING

Corpo in acciaio / Steel body


A060676.02.00 190 147 126 83 40 40 39.5 20 80 40 20 40 10.5 12 OR 3068 17.12x2.62
A060676.03.00 190 147 126 83 40 40 39.5 20 80 40 20 40 10.5 12 OR 3068 17.12x2.62
COD. L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 D F O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with close centre spools.
a centro chiuso in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from A to C1, to hold
usso libero da A verso C1, the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump
o a pompa ferma, controllo not running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola relief function against
PIOMBATURA CODE pilotaggio, protezione overpressure in the cylinder.
916013 da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2, C1 3/4"G
A060676.02.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3.15 kg
S 1/4"G
V1, V2, C1 3/4"G
A060676.03.00 8:1 150-350 bar 350 bar 82 bar/turn 150 l/min 500 bar 3.15 kg
S 1/4"G
Pag. 06.02.06

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter valve "BR series"

F
V2

=
C2

=
L3
Pil

)
2
HEX5

(n
D
HEX17
V2

F
S
S1
CURVE CARATTERISTICHE Pil

F1
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
21
= =

S2
18
H2 H1 H
15
V2

12
C2
C2

=
6
C2

=
3 V2
0 L2
20 40 60 80 100120 140 160180 200
L L1
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


A060861.01.00 160 8.5 35 77 100 55 10 50 119.5 ~82 112 35 10.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole a centro centre spools. To be connected
aperto in neutro. Collegare as shown. The valve allows:
allimpianto come da schema. free ow from V2 to C2,
La valvola permette: usso libero to hold the load with spool
da V2 verso C2, sostentamento del in neutral position or with
carico con distributore in neutro the pump not running,
o a pompa ferma, controllo controlled movement when
del movimento di discesa del carico pilot pressure is applied,
a seguito del pilotaggio della relief function against
valvola pilotaggio, protezione overpressure in the cylinder.
da sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Port Size Weight
Code Range Setting Increase Max Flow Pressure
C2-V2 1"G
A060861.01.00 8,3:1 100-350 bar 350 bar 80 bar/turn 200 l/min 350 bar 2.9 kg
Pil 1/4"G
Pag. 06.02.07

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter valve "BR series"

H3 H2

Pil
HEX5

L1
HEX17

L4
C1 A

C1

L
L3
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

L2
28
24
20
Pil
16 H1
12
A
8
C1 A C1
4
=
S

0
20 40 60 80 100 120 140
=

PORTATA / FLOW - Q (l/min) H1 D (n2)


H

Corpo in acciaio / Steel body


A060600.02.00 135 ~84 72.5 101 10 40 90 38 70 10 10.5
COD. L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata per suggested for use with open
distributori con spole a centro centre spools. To be connected
aperto in neutro. Collegare as shown. The valve allows:
allimpianto come da schema. free ow from A to C1,
La valvola permette: usso libero to hold the load with spool
da A verso C1, sostentamento in neutral position or with
del carico con distributore the pump not running,
in neutro o a pompa ferma, controlled movement when
controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola overpressure in the cylinder.
PIOMBATURA CODE pilotaggio, protezione da
916005 sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, C1 3/4"G
A060600.02.00 8.2:1 100-400 bar 350 bar 90 bar/turn 140 l/min 500 bar 3.5 kg
Pil 1/4"G
Pag. 06.02.08

Valvola di bilanciemento semplice eetto, serie BR


Single overcenter valve "BR series"

=
C2 C1

=
S L2
HEX5
= =
HEX17
V2 V1

D (n2)

H2
H
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

H3
L1
28 H1 L L5
24
20
16
12
V2
8 C2
4 C2 V2
=

0
20 40 60 80 100 120 140
=

PORTATA / FLOW - Q (l/min)


L4 L3

Corpo in acciaio / Steel body


A060600.01.00 135 10 34 62.5 50.5 83 40 90 7.5 70 10 10.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from V2 to C2,
da schema. La valvola permette: to hold the load with spool
usso libero da V2 verso C2, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo del when pilot pressure is applied,
movimento di discesa del carico relief function against
a seguito del pilotaggio della overpressure in the cylinder.
valvola pilotaggio, protezione
da sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060600.01.00 4.4:1 100-350 bar 350 bar 90 bar/turn 140 l/min 400 bar 3/4"G 3.4 kg
Pag. 06.02.09
00.00.00

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"

HEX10

H3max
F
HEX13

V2 C2 Pil
V2

H
H1
H2
S
Pil
S1

L3
C2
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

L4
25
Pil

L2
PRESSIONE / PRESSURE -

20

L
15
V2
10
C2
C2
5
V2
0 10 20 30 40 50 60

L1
PORTATA / FLOW - Q (l/min) HEX30
V2

Corpo in acciaio / Steel body


A060461.15.00 96.5 29.5 64 5 27 40 30 40 11 8 21 32 M6
COD. L L1 L2 L3 L4 S S1 H H1 H2 H3 F D

DESCRIZIONE DESCRIPTION

Collegare allimpianto To be connected as shown.


come da schema. Il pilotaggio The pilot signal is taken from
della valvola prelevato the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero with spool in neutral position
da V2 verso C2, il sostentamento or with the pump not running,
del carico con distributore controlled movement when
in neutro o pompa ferma, pilot pressure is applied,
controllo della discesa a valvola relief function against
pilotata e protezione contro overpressure in the cylinder.
sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard


Setting
Pressure
Increase
Max
Flow
Max
Pressure Port Size Weight
V2-C2 1/2"G
A060461.15.00 4.25:1 140-320 bar 280 bar 190 bar/turn 60 l/min 350 bar 1.14 kg
Pil 1/4"G
Pag. 06.02.10
00.00.00

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"
S3

S2
B V

L2

S1
B V

S
A

L1
A F

CURVE CARATTERISTICHE F Hex 30


p (bar)

PERFORMANCE CURVES L3 L4
25
H H1
PRESSIONE / PRESSURE -

20 D n.4

F1
15 F V
F B V
V

=
10

F
5

=
F2 max.

0 20 40 60 80

PORTATA / FLOW - Q (l/min)


H3 H2 HEX13

Corpo in acciaio / Steel body

A060461.16.00 76 49 23 31.5 35 95 25 6 70 35 5 20 36 40 10 23 M8
COD. L L1 L2 L3 L4 S S1 S2 S3 H H1 H2 H3 F F1 F2 max D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from F to V,
usso libero da F verso V, to hold the load with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure
del carico a seguito del is applied, relief function
pilotaggio della valvola against overpressure
pilotaggio, protezione in the cylinder.
da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060461.16.00 4.25:1 120-350 bar 250 bar 190 bar/turn 60 l/min 400 bar 1/2"G 1.7 kg
Pag. 06.05.01

Valvola di bilanciamento semplice eetto, serie BR


Single overcenter valve "BR series"

F
L1 L
C1 C2 L2
L3

HEX3
S1 C1 C2
HEX10

A B

H1
H
S1

H3
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
A B

H2
10 HEX 24 L4 L5
PRESSIONE / PRESSURE -

8
6
A D (n.2)
4
C1 C1
2 A
0

=
10 20 30 40 50 60

L6
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
A060421.00.00 110 ~50 71 29.5 52.5 40.5 30 60 44 8 22 8.25
A060421.01.00 110 ~50 71 29.5 52.5 40.5 30 60 44 8 22 8.25
COD. L L1 L2 L3 L4 L5 L6 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure is applied,
del carico a seguito del relief function against
pilotaggio della valvola overpressure in the cylinder.
pilotaggio,protezione The max valve opening
CODICE ORDINAZIONE SEALING ORDERING da sovrapressioni nel cilindro. is adjustable.
PIOMBATURA CODE L'apertura massima della
916001 valvola pu essere regolata.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060421.00.00 4.84:1 100-350 bar 300 bar 125 bar/turn 60 l/min 500 bar 1/2"G 1.5 kg
A060421.01.00 4.84:1 50-210 bar 180 bar 41 bar/turn 60 l/min 500 bar 1/2"G 1.5 kg
Pag. 06.06.01

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

L1 L
C1
L2
L3
SFIATO/ C1
P AIR BLEED

H
P

H1
CURVE CARATTERISTICHE
p (bar)

H2
PERFORMANCE CURVES
10 HEX 17
A

H3
L4 L5
PRESSIONE / PRESSURE -

8
6 D (n.2)
A
4
C1 C1
2

=
A

S
0 10 20 30 40 50

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060326.00.00 88 61 45 27.5 49 12 30 60 26 21 7 8.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected
allimpianto come da schema. as shown neutral. The valve
La valvola permette: allows: free ow from A to C1,
usso libero da A verso C1, to hold the load position
sostentamento del carico with spool in neutral position
con distributore in neutro or with the pump not running,
o a pompa ferma, controllo controlled movement when
del movimento di discesa del pilot pressure is applied,
carico a seguito del pilotaggio relief function against
della valvola pilotaggio, overpressure in the cylinder
protezione da sovrappressioni when an auxiliary relief
nel cilindro, se sullelemento valve is tted in the spool
del distributore montata valve and set at least 15 bar
una valvola limitatrice lower than the valve.
CODICE ORDINAZIONE SEALING ORDERING di pressione ausiliaria,
PIOMBATURA CODE da tarare almeno 15 bar
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, C1 3/8"G
A060326.00.00 4.84:1 100-350 bar 250 bar 150 bar/turn 45 l/min 500 bar 1.2 kg
P 1/4"G
Pag. 06.06.02

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

F
L1 L
L2
C1
L3
L4

P SFIATO/ C1
AIR BLEED
A

H1
H
p (bar)

CURVE CARATTERISTICHE P
PERFORMANCE CURVES

H3
10
PRESSIONE / PRESSURE -

HEX 17
8 A

H2
D (n.2)
6
A
4
C1 C1

=
2 A

S
0
10 20 30 40 50 60

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060426.00.00 96 59 70.5 52.5 30 30 60 50 5 20 6.25
COD. L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected
allimpianto come da schema. as shown neutral.
La valvola permette: The valve allows: free ow
usso libero da A verso C1, from A to C1, to hold the load
sostentamento del carico position with spool in neutral
con distributore in neutro position or with the pump
o a pompa ferma, controllo not running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione da overpressure in the cylinder
sovrappressioni nel cilindro, when an auxiliary
se sullelemento del distributore relief valve is tted
montata una valvola limitatrice in the spool valve and set
CODICE ORDINAZIONE SEALING ORDERING di pressione ausiliaria, at least 15 bar lower
PIOMBATURA CODE da tarare almeno 15 bar than the valve.
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Weight


Range Setting Increase Max Flow Pressure Port Size
A, C1 1/2"G
A060426.00.00 4.84:1 100-350 bar 250 bar 150 bar/turn 60 l/min 500 bar 1.3 kg
P 1/4"G
Pag. 06.06.03

Valvola di bilanciamento semplice eetto, serie 165 CC


Single overcenter valve "165 CC series"
L1 L L7
F
L3 L4
C1
Y

H1
SFIATO/AIR
BLEED C1
P

=
P
A

H
p (bar)

X
=
CURVE CARATTERISTICHE
PERFORMANCE CURVES C
Y A
25 L5
PRESSIONE / PRESSURE -

L2
20
15 A C1 D (n.2)
A
10 C1

=
5

L6
0 10 20 30 40 50 60

=
PORTATA / FLOW - Q (l/min)
Corpo in acciaio / Steel body
91 52 51 25.6 47.6 19 30 21 55 7 HEX17 8.5 1/4"G 1/4"G
91 52 51 25.6 47.6 19 30 21 55 7 HEX17 8.5 3/8"G 3/8"G
91 52 51 25.6 47.6 19 35 21 65 11 HEX17 8.5 1/4"G 1/2"G
L L1 L2 L3 L4 L5 L6 L7 H H1 C D X Y

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral position.
chiuso in neutro. Collegare To be connected as shown neutral.
allimpianto come da schema. The valve allows: free ow from
La valvola permette: usso libero A to C1, to hold the load position
da A verso C1, sostentamento with spool in neutral position
del carico con distributore in neutro or with the pump not running,
o a pompa ferma, controllo del controlled movement when pilot
movimento di discesa del carico pressure is applied, relief function
a seguito del pilotaggio della against overpressure in the cylinder
valvola pilotaggio, protezione when an auxiliary relief valve
da sovrappressioni nel cilindro, is tted in the spool valve
se sullelemento del distributore and set at least 15 bar
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice lower than the valve.
PIOMBATURA CODE di pressione ausiliaria tarata 15 bar
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060266.01.00 2.7:1 80-350 bar 350 bar 105 bar/turn 20 l/min 500 bar 1/4"G 1.2 kg
A060266.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 20 l/min 500 bar 1/4"G 1.2 kg
A060266.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 20 l/min 500 bar 1/4"G 1.2 kg
A060366.11.00 2.7:1 80-350 bar 350 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060366.12.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060366.13.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.2 kg
A060466.01.00 2.7:1 80-350 bar 350 bar 105 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060466.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060466.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
Pag. 06.06.04

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

F
L1 L
C1 L3
L2
S

P C1 S

H4
H2

H3
H1
A

H
P
p (bar)

HEX 17 A
CURVE CARATTERISTICHE
PERFORMANCE CURVES SFIATO/AIR BLEED Y
10
PRESSIONE / PRESSURE -

8
S1

6
A
4
S2

C1 C1
2 A
S

0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min) HEX27

Corpo in acciaio / Steel body


A060416.11.00 104 59 30 59 35 18 4 80 50 26 46 M22x1.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 H3 Y

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole centro closed center spools in neutral
chiuso in neutro. Collegare position. To be connected
allimpianto come da schema. as shown neutral.
La valvola permette: The valve allows: free ow
usso libero da A verso C1, from A to C1, to hold the load
sostentamento del carico position with spool in neutral
con distributore in neutro position or with the pump
o a pompa ferma, controllo not running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione overpressure in the cylinder
da sovrappressioni nel cilindro, when an auxiliary relief valve
se sullelemento is tted in the spool valve
del distributore montata and set at least 15 bar
una valvola limitatrice lower than the valve.
CODICE ORDINAZIONE SEALING ORDERING di pressione ausiliaria,
PIOMBATURA CODE da tarare almeno 15 bar
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A 1/2"G
A060416.11.00 11:1 100-400 bar 350 bar 210 bar/turn 60 l/min 500 bar 2.4 kg
P, S 1/4"G
Pag. 06.07.01

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

F L1 L
L2
C1 C2 L3
SFIATO/AIR BLEED C1 C2

A B

H1
H
H3
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES C A B

H2
10 L4 L5
PRESSIONE / PRESSURE -

8 D (n.2)
6
A
4

L7
C1 C1

L6
2
A
0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060326.20.00 107 61 67.5 27.5 49.5 40.5 30 15 60 44 8 26 HEX17 8.5
A060426.20.00 110 59 71 29.5 52.5 40.5 30 15 60 44 8 22 HEX17 8.25
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 H3 C D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole center spools in neutral
centro chiuso in neutro. position. To be connected
Collegare allimpianto come as shown neutral. The valve
da schema. La valvola permette: allows: free ow from A to C1,
usso libero da A verso C1, to hold the load position
sostentamento del carico with spool in neutral position
con distributore in neutro or with the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder
pilotaggio, protezione when an auxiliary relief
da sovrappressioni nel valve is tted in the spool
cilindro, se sullelemento valve and set at least 15 bar
del distributore montata lower than the valve.
una valvola limitatrice
CODICE ORDINAZIONE SEALING ORDERING di pressione ausiliaria
PIOMBATURA CODE tarata 15 bar in meno
916001 rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060326.20.00 4.84:1 100-350 bar 250 bar 150 bar/turn 45 l/min 500 bar 3/8"G 1.4 kg
A060426.20.00 4.84:1 100-350 bar 280 bar 150 bar/turn 60 l/min 500 bar 1/2"G 1.4 kg
Pag. 06.07.02

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

L1 L
F
L3 L2
L4

H2
C1 C2
C1 C2

SFIATO/AIR BLEED

H3
A B

H1
H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES L5
A L6
B
HEX 17
PRESSIONE / PRESSURE -

14 D (n.2)
12
10
8
6 C1
A
=

4 A
S

2 C1
0
=

10 20 30 40 50 60

PORTATA / FLOW -Q(l/min)

Corpo in acciaio / Steel body


A060426.30.00 111 61 63 30 8 52.5 40.5 35 70 54 8 38 8.5
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected as
allimpianto come da schema. shown neutral. The valve allows:
La valvola permette: usso free ow from A to C1, to hold
libero da A verso C1, the load position with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder
pilotaggio, protezione when an auxiliary relief valve
da sovrappressioni nel cilindro, is tted in the spool valve
se sullelemento del distributore and set at least 15 bar lower
montata una valvola than the valve.
CODICE ORDINAZIONE SEALING ORDERING limitatrice di pressione ausiliaria,
PIOMBATURA CODE da tarare almeno 15 bar
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060426.30.00 3.24:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 1.95 kg
Pag. 06.07.03

Valvola di bilanciamento semplice eetto, serie 165 CC


Single overcenter valve "165 CC series"

L6 L
F
L1 L7
C1 C2 L2 L3
S Y Y
SFIATO/AIR BLEED

H1
C1 C2
A B

H
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20 HEX 17
C1 A Y S Y B
15 A X
A HEX 4 L5 S
10 C1 L4 D (n.2)
5

0 10 20 30 40 50 60

L8
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


109 52 32 40 54 19.5 52 39 30 55 8 HEX17 8.5 1/4"G 1/4"G
109 52 32 40 54 19.5 52 39 30 55 8 HEX17 8.5 1/4"G 3/8"G
109 52 32 40 54 19.5 52 39 35 65 8 HEX17 8.5 1/4"G 1/2"G
L L1 L2 L3 L4 L5 L6 L7 L8 H H1 C D X Y

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve, suggested


eetto, consigliata per distributori for use with closed center spools
con spole centro chiuso in neutro. in neutral position. To be connected
Collegare allimpianto come da as shown neutral . The valve allows:
schema. La valvola permette: usso free ow from A to C1, to hold
libero da A verso C1, sostentamento the load position with spool
del carico con distributore in neutro in neutral position or with the pump
o a pompa ferma, controllo del not running, controlled movement
movimento di discesa del carico when pilot pressure is applied,
a seguito del pilotaggio della valvola relief function against overpressure
pilotaggio, protezione in the cylinder when an auxiliary
da sovrappressioni nel cilindro, relief valve is tted in the spool
se sullelemento del distributore valve and set at least 15 bar lower
CODICE ORDINAZIONE SEALING ORDERING
montata una valvola limitatrice than the valve.
PIOMBATURA CODE
di pressione ausiliaria tarata 15 bar
916001 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060266.04.00 2.7:1 80-350 bar 300 bar 105 bar/turn 20 l/min 500 bar 1/4"G 1.40 kg
A060266.05.00 4.3:1 100-350 bar 350 bar 160 bar/turn 20 l/min 500 bar 1/4"G 1.40 kg
A060266.06.00 8.8:1 100-350 bar 350 bar 115 bar/turn 20 l/min 500 bar 1/4"G 1.40 kg
A060366.14.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.35 kg
A060366.15.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.35 kg
A060366.16.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.35 kg
A060466.04.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 1.75 kg
A060466.05.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 1.75 kg
A060466.06.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 1.75 kg
Pag. 06.07.04

Valvola di bilanciamento semplice eetto, serie 210 CC


Single overcenter valve "210 CC series"

F
X L
S C1 C2 L2

L3 L4
HEX24

H2
C2 C1

A B

H
H1
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
B S A L5
25
L6
PRESSIONE / PRESSURE -

20
L1
15 SFIATO/
A D (n.2)
10 AIR BLEED
C1
5 C1
A
0

=
20 40 60 80 100 120

S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
A060466.12.00 187 141 122.5 40 62.5 39 82.5 40 60 30 10 8.5
A060466.13.00 187 141 122.5 40 62.5 39 82.5 40 60 30 10 8.5
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral position.
chiuso in neutro. Collegare To be connected as shown
allimpianto come da schema. neutral. The valve allows:
La valvola permette: usso libero free ow from A to C1,
da A verso C1, sostentamento to hold the load position
del carico con distributore with spool in neutral position
in neutro o a pompa ferma, or with the pump not running,
controllo del movimento controlled movement
di discesa del carico a seguito when pilot pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione da overpressure in the cylinder
sovrappressioni nel cilindro, when an auxiliary relief valve
se sullelemento del distributore is tted in the spool valve
montata una valvola limitatrice and set at least 15 bar lower
CODICE ORDINAZIONE SEALING ORDERING di pressione ausiliaria tararata than the valve.
PIOMBATURA CODE 15 bar in meno rispetto
916013 alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
100-350 A, B, C1, C2 1/2"G
A060466.12.00 4:1 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.5 kg
S 1/4"G
150-350 A, B, C1, C2 1/2"G
A060466.13.00 8:1 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.5 kg
S 1/4"G
Pag. 06.07.05

Valvola di bilanciamento semplice eetto, serie 210 CC


Single overcenter valve "210 CC series"

F X L
L1
S C1 C2
L2
L3
C2 C1
SFIATO/
A B AIR BLEED

H
p (bar)

CURVE CARATTERISTICHE

H1
PERFORMANCE CURVES

H2
25
PRESSIONE / PRESSURE -

20 B = =S A L4
15 A L5
10 HEX 24
C1 C1
D (n.2)
5
A
0 25 50 75 100 125 150

=
S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
A060666.02.00 193 147 126 83 40 40 40 80 40 20 10.5
A060666.03.00 193 147 126 83 40 40 40 80 40 20 10.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata per suggested for use with closed
distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected
allimpianto come da schema. as shown neutral. The valve
La valvola permette: usso libero allows: free ow from A to C1,
da A verso C1, sostentamento to hold the load position
del carico con distributore in with spool in neutral position
neutro o a pompa ferma, or with the pump not running,
controllo del movimento di controlled movement when
discesa del carico a seguito del pilot pressure is applied,
pilotaggio della valvola pilotaggio, relief function against
protezione da sovrappressioni overpressure in the cylinder
nel cilindro, se sullelemento when an auxiliary relief valve
del distributore montata una is tted in the spool valve
CODICE ORDINAZIONE SEALING ORDERING valvola limitatrice di pressione and set at least 15 bar
PIOMBATURA CODE ausiliaria tararta 15 bar lower than the valve.
916013 in menorispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, B, C1, C2 3/4"G
A060666.02.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3.3 kg
S 1/4"G
A, B, C1, C2 3/4"G
A060666.03.00 8:1 150-350 bar 350 bar 82 bar/turn 150 l/min 500 bar 3.3 kg
S 1/4"G
Pag. 06.07.06

Valvola di bilanciamento semplice eetto, serie BRCC


Single overcenter valve "BRCC series"

F L1 L
L2
C1 C2
L4 L3
C1 C2
SFIATO/AIR BLEED
A B

H1
H
p (bar)

CURVE CARATTERISTICHE

H3
PERFORMANCE CURVES
28
PRESSIONE / PRESSURE -

HEX4 L5
24 A B

H2
20 HEX17 D (n.2)
16
12
A
8 C1
C1

=
4 A

S
0 20 40 60 80 100 120 140

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


~84 101 22 50.5 10 40 90 70 10 38 10.5
A060626.01.00 135 ~84 101 22 50.5 10 40 90 70 10 38 10.5
A060626.02.00 135
L L1 L2 L3 L4 L5 S H H1 H2 H3 D
COD.

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected as
allimpianto come da schema. shown neutral . The valve
La valvola permette: allows: free ow from A to C1,
usso libero da A verso C1, to hold the load position with
sostentamento del carico spool in neutral position or with
con distributore in neutro o a the pump not running,
pompa ferma, controllo del controlled movement
movimento di discesa del carico when pilot pressure is applied,
a seguito del pilotaggio della relief function against
valvola pilotaggio, protezione overpressure in the cylinder
da sovrappressioni nel cilindro, when an auxiliary relief valve
se sullelemento del distributore is tted in the spool valve
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice di and set at least 15 bar lower
PIOMBATURA CODE pressione ausiliaria tararta 15 bar than the valve.
916005 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060626.01.00 4.4:1 100-350 bar 300 bar 90 bar/turn 140 l/min 500 bar 3/4"G 3.4 kg
A060626.02.00 8.2:1 100-400 bar 350 bar 90 bar/turn 140 l/min 500 bar 3/4"G 3.4 kg
Pag. 06.08.02

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F L1 L
L2
C1 S
HEX4
L3
HEX13 A S
P

H2
A
P

H
C1

H1
H3
CURVE CARATTERISTICHE L4
p (bar)

PERFORMANCE CURVES
25

S2
PRESSIONE / PRESSURE -

20

S1
15 A

S
10 C1 C1
5 A

0 HEX24
10 20 30 40 50

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060391.02.00 100 ~42 53.5 19.5 45 30 3 15 60 32 28 15
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 H3

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata per suggested for use with
distributori con spole a centro open centre spools.
aperto in neutro. Collegare To be connected as shown.
allimpianto come da schema. The valve allows:
La valvola permette: usso libero free ow from A to C1,
da A verso C1, sostentamento to hold the load with spool
del carico con distributore in in neutral position or with
neutro o a pompa ferma, the pump not running,
controllo del movimento controlled movement when
di discesa del carico a seguito pilot pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio,protezione da overpressure in the cylinder.
sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, C1 3/8"G
A060391.02.00 4.3:1 100-400 bar 350 bar 135 bar/turn 45 l/min 500 bar 1.4 kg
P, S 1/4"G
Pag. 06.08.02A

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F
L1 L L2
L3
C2 M C1 L4
L5
L6

H1
M
V2 V1
HEX13
V2 V1

H
CURVE CARATTERISTICHE
p (bar)

H2
PERFORMANCE CURVES HEX4

H3
25
PRESSIONE / PRESSURE -

20 C1

15 V2 C2 HEX10

S2
10 C2 C2

S3
5 V2

S
0 10 20 30 40 50 HEX3

PORTATA / FLOW - Q (l/min)


HEX24

S1
Corpo in alluminio / Aluminium body
B060391.11.00 109 ~42 ~10 92 62 51.5 22 30 8 15 3 60 5 30 14
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V1 to C1, to
usso libero da V1 verso C1, hold the load with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running,
o a pompa ferma, controllo del controlled movement when
movimento di discesa del carico pilot pressure is applied,
a seguito del pilotaggio della relief function against
valvola pilotaggio, protezione overpressure in the cylinder.
da sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2, C1, C2 3/8"G
B060391.11.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 0.7 kg
M 1/4"G
Pag. 06.08.02B

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F
L1 L

C1 L2
HEX13
L3
A1 P

H4
HEX4
S

X P

A1 A1 A1

H
H2
H6
A1

H3
p (bar)

H5
CURVE CARATTERISTICHE
PERFORMANCE CURVES
A1 S
25

H1
L6 L5 L4
PRESSIONE / PRESSURE -

20 X

15 A1 D

S1
10 C1 C1
5 A1

S
0 10 20 30 40 50

=
PORTATA / FLOW - Q (l/min)
HEX38

Corpo in acciaio / Steel body


A063691.02.00 112 35 63.5 16 22 31.5 31 34.5 13.5 70 4.5 22.5 20 7 14.5 42.5 8.5 1.75
A063691.05.00 112 35 63.5 16 22 31.5 31 34.5 13.5 70 4.5 22.5 20 7 14.5 42.5 8.5 2.5
COD. L L1 L2 L3 L4 L5 L6 S S1 H H1 H2 H3 H4 H5 H6 D X

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected
Collegare allimpianto come as shown. The valve allows:
da schema. La valvola permette: free ow from A1 to C1,
usso libero da A1 verso C1, to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump not running,
o a pompa ferma, controllo del controlled movement
movimento di discesa del carico when pilot pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING a seguito del pilotaggio della relief function against
PIOMBATURA CODE valvola pilotaggio, protezione overpressure in the cylinder.
916003 da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A1, P M16x1.5
A063691.02.00 4.25:1 100-400 bar 380 bar 135 bar/turn 45 l/min 500 bar C1 M20x1.5 2 kg
S 1/4"G
A1, P M16x1.5
A063691.05.00 4.25:1 100-400 bar 380 bar 135 bar/turn 45 l/min 500 bar C1 M20x1.5 2 kg
S 1/4"G
Pag. 06.08.02C

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

L1 L
F
L2 L3
C1
HEX4
A1
HEX13
P

A1
P

H
H1
p (bar)

CURVE CARATTERISTICHE

H2
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20
A1 C1 C1

S1
15
10 C1 A1

S3
=
5

S
0

=
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

S2
HEX24
Corpo in acciaio / Steel body
95 ~41.4 20 35 30 15 8 3 60 33 14
L L1 L2 L3 S S1 S2 S3 H H1 H2

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from A1 to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da A1 verso C1, in neutral position or with
sostentamento del carico con the pump not running,
distributore in neutro o a controlled movement when
pompa ferma, controllo del pilot pressure is applied,
movimento di discesa del carico relief function against
a seguito del pilotaggio della overpressure in the cylinder.
valvola pilotaggio, protezione
da sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A1, C1 3/8"G
A060391.13.00 2.75:1 80-350 bar 350 bar 85 bar/turn 60 l/min 500 bar 1.4 kg
P 1/4"G
A1, C1 3/8"G
A060391.14.00 4.25:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1.4 kg
P 1/4"G
A1, C1 3/8"G
A060391.15.00 8.75:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1.4 kg
P 1/4"G
Pag. 06.08.02D

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F L L2

M C1
L1
L3

H2
HEX13

HEX4
P

V
M

H1
H
H3
p (bar)

CURVE CARATTERISTICHE V P
PERFORMANCE CURVES

H4
25
PRESSIONE / PRESSURE -

20
15 V C1 D
C1

S1
10 C1 V

S3
5

=
S
0 10 20 30 40 50 60

=
PORTATA / FLOW - Q (l/min)

S2
HEX27
Corpo in acciaio / Steel body
100 ~42 5 48.5 35 18 8 4 80 50 11.5 52.5 17 M22x1.5
L L1 L2 L3 S S1 S2 S3 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole a centro open centre spools.
aperto in neutro. Collegare To be connected as shown.
allimpianto come da schema. The valve allows: free ow
La valvola permette: usso libero from V to C1, to hold
da V verso C1, sostentamento the load with spool
del carico con distributore in in neutral position or
neutro o a pompa ferma, with the pump not running,
controllo del movimento controlled movement
di discesa del carico a seguito when pilot pressure
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola is applied, relief function
PIOMBATURA CODE pilotaggio, protezione against overpressure
916003 da sovrapressioni nel cilindro. in the cylinder.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V 1/2"G
A060491.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 2.1 kg
P, M 1/4"G
V 1/2"G
A060491.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 2.1 kg
P, M 1/4"G
V 1/2"G
A060491.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 2.1 kg
P, M 1/4"G
V 1/2"G
A060491.04.00 11:1 100-350 bar 350 bar 116 bar/turn 60 l/min 500 bar 2.1 kg
P, M 1/4"G
Pag. 06.08.02E

Valvola di bilanciamento semplice eetto, serie 210 angiabile


Flangeable single overcenter valve "210 series"

F
L1 L L2
L3
M C1 HEX24

P
M
V

H1
H
H4
V P
p (bar)

H2
H3
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE -

25
D
20

S1
15 A
10 C1

S2
=
C1
5

S
A
0

=
20 40 60 80 100 120

PORTATA / FLOW - Q (l/min) HEX32

Corpo in acciaio / Steel body


A060491.06.00 137 ~43 5 55.5 40 18 4 90 56.5 18.5 17 57 M27x1.5
A060491.07.00 137 ~43 5 55.5 40 18 4 90 56.5 18.5 17 57 M27x1.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from V to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da V verso C1, in neutral position or with
sostentamento del carico con the pump not running,
distributore in neutro o a pompa controlled movement when
ferma, controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V 1/2"G
A060491.06.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
V 1/2"G
A060491.07.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
Pag. 06.08.02F

Valvola di bilanciamento semplice eetto, serie 210 CC


Single overcenter valve "210 CC series"

F L1 L L2

L3
M C1 HEX24

P
M

H1
V

H
H4
V P
p (bar)

H2
H3
CURVE CARATTERISTICHE
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20 D
C1

S1
15 V
10

S2
C1 C1

=
5 V

S
0
20 40 60 80 100 120

=
PORTATA / FLOW - Q (l/min) HEX27

Corpo in acciaio / Steel body


A060496.01.00 137 ~46 5 55.5 40 18 4 90 56.5 18.5 17 57 M22x1.5
A060496.02.00 137 ~46 5 55.5 40 18 4 90 56.5 18.5 17 57 M22x1.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve ,


semplice eetto, consigliata per suggested for use with closed
distributori con spole centro center spools in neutral position
chiuso in neutro . Collegare . To be connected as shown
allimpianto come da schema . La neutral . The valve allows: free
valvola permette: usso libero ow from V to C1, to hold the
da V verso C1 , sostentamento load position with spool in
del carico con distributore in neutral position or with the
neutro o a pompa ferma, pump not running, controlled
controllo del movimento di movement when pilot pressure
discesa del carico a seguito del is applied, relief function
pilotaggio della valvola against overpressure in the
pilotaggio, protezione da cylinder when an auxiliary relief
sovrappressioni nel cilindro, se valve is tted in the spool valve
sullelemento del distributore and set at least 15 bar lower
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice than the valve.
PIOMBATURA CODE di pressione ausiliaria tararta 15
916013 bar in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V 1/2"G
A060496.01.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
V 1/2"G
A060496.02.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
Pag. 06.08.04
Valvola di bilanciamento semplice eetto, serie 165 angiabile con valvola
paracadute su attacco M
Flangeable single overcenter valve "165 series" with hoseburst valve inside the M port
L1 L

F L2
HEX13
M C1
M
HEX4

H1
H
V

H3
V P
p (bar)

CURVE CARATTERISTICHE
H4

H2
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20 D
C1

S1
15 V C1
10 C1 V

S3
=
5

S
0
10 20 30 40 50 60

=
PORTATA / FLOW - Q (l/min)

S2
HEX27
Corpo in acciaio / Steel body
A060491.05.00 100 ~42 48.5 35 18 8 4 80 50 18.5 52.5 17 M22x1.5
COD. L L1 L2 S S1 S2 S3 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole a open centre spools.
centro aperto in neutro. To be connected as shown.
Collegare allimpianto come da The valve allows:
schema. La valvola permette: free ow from V to C1,
usso libero da V verso C1, to hold the load with spool
sostentamento del carico in neutral position or
con distributore in neutro with the pump not running,
o a pompa ferma, controllo del controlled movement
movimento di discesa del carico when pilot pressure is
a seguito del pilotaggio della applied, relief function
valvola pilotaggio, protezione against overpressure
da sovrapressioni nel cilindro. in the cylinder.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V 1/2"G
A060491.05.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 2.1 kg
P, M 1/4"G
Pag. 06.08.04A
Valvola di bilanciamento semplice eetto, serie 210 angiabile
con valvola paracadute su attacco M
Flangeable single overcenter valve "210 series" with hose burst valve inside the M port

L1 L
F
L2
M C1 HEX24
M

H1
H
H3 V P
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

H2
H4
25
PRESSIONE / PRESSURE -

20
15 D
A C1

S3

S1
10 C1 C1
5 A

=
0
20 40 60 80 100 120

S
PORTATA / FLOW - Q (l/min)

=
S2
HEX32

Corpo in acciaio / Steel body


A060491.08.00 137 ~43 55.5 40 18 8 4 90 56.5 18.5 57 17 M27x1.5
A060491.09.00 137 ~43 55.5 40 18 8 4 90 56.5 18.5 57 17 M27x1.5
COD. L L1 L2 S S1 S2 S3 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1;
usso libero da A verso C1; to hold the load with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running;
o a pompa ferma; controllo controlled movement
del movimento di discesa when pilot pressure
del carico a seguito is applied, relief function
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola against overpressure
PIOMBATURA CODE pilotaggio, protezione in the cylinder.
916013 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V 1/2"G
A060491.08.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
V 1/2"G
A060491.09.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 3.7 kg
P, M 1/4"G
Pag. 06.09.01

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

L5 L S
F
L2 L3
C1 S C2
HEX4 Y X Y

HEX13 A1 S C2

A B

C1

H1
H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

25
AY B
PRESSIONE / PRESSURE -

20 Y
L4
15 A C1 L1 L6
A
10 C1
D (n.4) D1 O-RING
5

=
10 20 30 40 50 60

L7
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
109 52 37 30 19.5 ~42 39 30 55 30 16 max. 8.5 9 1/4"G 1/4"G OR 3043 10.77x2.62
109 52 37 30 19.5 ~42 39 30 55 30 16 max. 8.5 9 1/4"G 3/8"G OR 3043 10.77x2.62
109 52 37 30 19.5 ~42 39 35 65 30 16 max. 8.5 9 1/4"G 1/2"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 L7 H H1 S D D1 X Y O-RING

DESCRIZIONE DESCRIPTION
Valvola di bilanciamento Single overcenter valve,
a semplice eetto, consigliata suggested for use with open
per distributori con spole a centro centre spools. To be connected
aperto in neutro. Collegare as shown. The valve allows:
allimpianto come da schema. free ow from A to C1;
La valvola permette: usso libero to hold the load with spool in
da A verso C1; sostentamento del neutral position or with
carico con distributore in neutro the pump not running;
o a pompa ferma; controllo controlled movement when
del movimento di discesa del carico pilot pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING a seguito del pilotaggio della relief function against
PIOMBATURA CODE valvola pilotaggio, protezione da overpressure in the cylinder.
916003 sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060271.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060271.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060271.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060371.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060371.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060371.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060471.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060471.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060471.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060471.16.00 7.25:1 150-450 bar 420 bar 230 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
Pag. 06.09.01B

Valvola di bilanciamento semplice eetto, serie 210 angiabile


Flangeable single overcenter valve "210 series"

F
L1 X
S C1 C2 L2
HEX24 L3 L4

A1 B1
A1 A B1 B

=
C1 C2

H1
H
=
p (bar)

CURVE CARATTERISTICHE A M B
PERFORMANCE CURVES
L5 L6

H2
25
PRESSIONE / PRESSURE -

L
20
15
A D (n.4) D1 O-RING
10
C1 C1
5
A
0

=
20 40 60 80 100 120

S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body

A060481.14.00 141 184 102 40 38.5 40 18.5 39.5 60 40 4.5 21 max. 10.5 12 OR 3068 17.12x2.62
A060481.15.00 141 184 102 40 38.5 40 18.5 39.5 60 40 4.5 21 max. 10.5 12 OR 3068 17.12x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 X D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1;
usso libero da A verso C1; to hold the load
sostentamento del carico with spool in neutral
con distributore in neutro position or with the pump
o a pompa ferma; controllo not running; controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola relief function against
PIOMBATURA CODE pilotaggio, protezione overpressure in the cylinder.
916013 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, B, A1, B1 1/2"G
A060481.14.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.35 kg
M 1/4"G
A, B, A1, B1 1/2"G
A060481.15.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.35 kg
M 1/4"G
Pag. 06.09.02

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

L5 L
F
L2 L3
C1 S C2 Y X Y
HEX4
HEX13 A1 S B1

A1 A B B1

=
C1 C2

H
H1
=
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25 A Y Y B
PRESSIONE / PRESSURE -

20 L4
L1 L6
15 A C1
10 C1 A D (n.4) D1 O-RING
5

=
0 10 20 30 40 50 60

L7
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
109 52 37 36 19.5 ~42 39 30 55 30 8.5 9 1/4"G 1/4"G OR 3043 10.77x2.62
109 52 37 36 19.5 ~42 39 30 55 30 8.5 9 1/4"G 3/8"G OR 3043 10.77x2.62
109 52 37 36 19.5 ~42 39 35 65 30 8.5 9 1/4"G 1/2"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 L7 H H1 D D1 X Y O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with
con spole a centro aperto in neutro. open centre spools.
Collegare allimpianto come To be connected as shown.
da schema. La valvola permette: The valve allows:
usso libero da A verso C1, free ow from A to C1,
sostentamento del carico to hold the load with spool
con distributore in neutro in neutral position
o a pompa ferma, controllo or with the pump not running,
del movimento di discesa controlled movement when pilot
CODICE ORDINAZIONE SEALING ORDERING del carico a seguito del pilotaggio pressure is applied, relief
PIOMBATURA CODE della valvola pilotaggio, protezione function against overpressure
916003 da sovrappressioni nel cilindro. in the cylinder.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060281.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060281.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060281.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 20 l/min 500 bar 1/4"G 1.3 kg
A060381.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060381.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060381.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 3/8"G 1.25 kg
A060481.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060481.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060481.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
A060481.06.00 7.25:1 150-450 bar 420 bar 230 bar/turn 60 l/min 500 bar 1/2"G 1.6 kg
Pag. 06.09.03

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F L1 L
L2 L3
C1 S C2

HEX4
A

=
=
A B B1 C1 C2

H
H1
=
B

=
HEX13 S

CURVE CARATTERISTICHE L6
p (bar)

PERFORMANCE CURVES L4 L5
10
D1 D2
D (n.4)
PRESSIONE / PRESSURE -

8 O-RING

6 A C1
C1

=
4 A

S
2

=
0 5 10 15 20 25

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060281.05.00 91 ~42 37 28 51 27 19 30 55 28 6.5 9 5 OR 115 11.91x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 D D1 D2 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come da The valve allows:
schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutr or with the pump
o a pompa ferma, controllo not running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola relief function against
PIOMBATURA CODE pilotaggio, protezione overpressure in the cylinder.
916003 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure

A060281.05.00 4.3:1 100-400 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.1 kg
Pag. 06.09.03A

Valvola di bilanciamento semplice eetto, serie 140 angiabile


Flangeable single overcenter valve "140 series"

HEX4
F
HEX13
M C1 C2

A A B B

D (n.4)
A A

L1
p (bar)

CURVE CARATTERISTICHE
C1

=
PERFORMANCE CURVES
L

L5
L2
25

=
M
PRESSIONE / PRESSURE -

L4
20 A
C1 C2
15
10 B
L3

C1

D1
A O-RING
5
B
= =
0 = =
5 10 15 20 25 30 H1 S
PORTATA / FLOW - Q (l/min) = =
H

Corpo in acciaio / Steel body


A060281.22.00 90 ~125 70.5 13 27 28 24.5 45 28 6.5 6 OR 112 9.92x2.62
COD. L L1 L2 L3 L4 L5 S H H1 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, suggested for use wit
consigliata per distributori open centre spools.
con spole a centro aperto To be connected as shown.
in neutro. Collegare allimpianto The valve allows: free ow
come da schema. La valvola from A to C1, to hold the load
permette: usso libero with spool in neutral position
da A verso C1, sostentamento or with the pump not running,
del carico con distributore controlled movement
in neutro o a pompa ferma, when pilot pressure is applied,
controllo del movimento relief function against
di discesa del carico a seguito overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola
PIOMBATURA CODE pilotaggio, protezione
da sovrappressioni nel cilindro.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060281.22.00 4.1:1 100-350 bar 250 bar 180 bar/turn 30 l/min 500 bar 1/4"G 0.7 kg
Pag. 06.09.04

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

F L4 L
L3
C1
= =
A
P

=
=
A1 A C1 P

H1

H
=

=
HEX13
CURVE CARATTERISTICHE A1
p (bar)

HEX4 L2
PERFORMANCE CURVES
L1
25
D
PRESSIONE / PRESSURE -

20 O-RING
D1 (n.4)
15 A
10 C1 C1

=
A

L5
5

=
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060271.12.00 91 51 19 28 42 30 55 28 9 6.5 OR 3043 10.77x2.62
A060371.12.00 91 51 19 28 42 30 55 28 9 6.5 OR 3043 10.77x2.62
COD. L L1 L2 L3 L4 L5 H H1 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure
del carico a seguito is applied, relief function
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola against overpressure
PIOMBATURA CODE pilotaggio, protezione in the cylinder.
916003 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060271.12.00 4.3:1 100-350 bar 350 bar 135 bar/turn 20 l/min 500 bar 1/4"G 1.1 kg
A060371.12.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.1 kg
Pag. 06.09.04A

Valvola di bilanciamento semplice eetto, serie 140 angiabile


Flangeable single overcenter valve "140 series"

HEX4
F

HEX13
M C1 C2

L1

D1 (n.4)
A A B
A A

C1

=
M

L5
CURVE CARATTERISTICHE

L
p (bar)

PERFORMANCE CURVES

L2

D
25

L4
PRESSIONE / PRESSURE -

20 A C2
B
15 C1 O-RING
L3
10
C1 = =
A = =
5
H1 S
0 5 10 15 20 25 30 = =
H
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060271.22.00 90 35 70.5 13 27 28 24.5 45 28 6 6.5 OR 112 9.92x2.62
COD. L L1 L2 L3 L4 L5 S H H1 D D1 COD.

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump
o a pompa ferma, controllo not running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
CODICE ORDINAZIONE SEALING ORDERING del pilotaggio della valvola relief function against
PIOMBATURA CODE pilotaggio, protezione overpressure in the cylinder.
916003 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060271.22.00 4.1:1 100-350 bar 300 bar 180 bar/turn 30 l/min 500 bar 1/4"G 0.7 kg
Pag. 06.09.04B

Valvola di bilanciamento semplice eetto, serie 140 angiabile


Flangeable single overcenter valve "140 series"

F
L4
L5
M1 C1 M C2 HEX4
= =
HEX13
A M B

=
=
H1

H
C1

=
A A B
A
C2

H2
p (bar)

M1
CURVE CARATTERISTICHE
PERFORMANCE CURVES L3 L2
25 L1 L
PRESSIONE / PRESSURE -

20 A
15 C1
10 C1

=
A

S
5

=
0 5 10 15 20 25 30
PORTATA / FLOW - Q (l/min) O-RING D
D1 (n.4)

Corpo in acciaio / Steel body


A060271.24.00 90 ~37 57.5 19.5 50 28 24.5 45 28 15 6.5 6 OR 112 9.92x2.62
COD. L L1 L2 L3 L4 L5 S H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from A to C1,
usso libero da A verso C1, to hold the load with spool
sostentamento del carico in neutral position or with
con distributore in neutro the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione A hose burst valve is tted
CODICE ORDINAZIONE SEALING ORDERING da sovrappressioni nel cilindro. inside the M port.
PIOMBATURA CODE La valvola integra la valvola
916003 paracadute sull'attacco M.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060271.24.00 4.1:1 100-350 bar 300 bar 180 bar/turn 30 l/min 500 bar 1/4"G 0.73 kg
Pag. 06.09.04C

Valvola di bilanciamento semplice eetto, serie 140 angiabile


Flangeable single overcenter valve "140 series"

F
L1 L

C1 C2 L2
M

H2
M A

=
C1 C2

=
B1

H1

H
A A B B

=
HEX13
A1 = = B2
HEX4
p (bar)

CURVE CARATTERISTICHE L5
PERFORMANCE CURVES
L3 L4
25
PRESSIONE / PRESSURE -

20 A
15 C1

=
S
10 C1

=
A
5
O-RING D
0 5 10 15 20 25 30 D1 (n.4)

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060281.24.00 90 ~35 19.5 50 27 28 24.5 45 28 15 6 6.5 OR 112 9.92x2.62
COD. L L1 L2 L3 L4 L5 S H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from A to C1,
da schema. La valvola permette: to hold the load with spool
usso libero da A verso C1, in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico a seguito del overpressure in the cylinder.
pilotaggio della valvola A hose burst valve
pilotaggio, protezione da is tted inside the M port.
CODICE ORDINAZIONE SEALING ORDERING sovrappressioni nel cilindro.
PIOMBATURA CODE La valvola integra la valvola
paracadute sull'attacco M.
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure

A060281.24.00 4.1:1 100-350 bar 250 bar 180 bar/turn 30 l/min 500 bar 1/4"G 0.7 kg
Pag. 06.09.05

Valvola di bilanciamento semplice eetto, serie 210 angiabile


Flangeable single overcenter valve "210 series"
F
L1 X
M C1 C2 L
L2 L3
L4

A C2
A B

=
C1

H2
H
=
H3
p (bar)

CURVE CARATTERISTICHE A B
PERFORMANCE CURVES M
25 HEX24 L5 L6
PRESSIONE / PRESSURE -

H1
20
15 D
A O-RING D1 (n.4)
10 C1 C1
5 A

=
0 20 50 60 80 100 120

S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
A060471.14.00 141 184 40 38.5 58.5 83.5 18.5 39.5 60 4.5 40 30 20 max. 12 10.5 OR 3068 17.13x2.62
A060471.15.00 141 184 40 38.5 58.5 83.5 18.5 39.5 60 4.5 40 30 20 max. 12 10.5 OR 3068 17.13x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 X D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from A to C1, to hold
usso libero da A verso C1, the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump not
o a pompa ferma, controllo running, controlled
del movimento di discesa movement when pilot
del carico a seguito pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione overpressure in the cylinder.
da sovrappressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max


Max Flow Pressure Port Size Weight
Range Setting Increase
A, B, C2 1/2"G
A060471.14.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.35 kg
M 1/4"G
A, B, C2 1/2"G
A060471.15.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.35 kg
M 1/4"G
Pag. 06.09.05A

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter valve "165 series"

D(n4) S2

H3
H2
A1
M

X2
X1 HEX30 B L3
S1
X2 O-RING
B = =

=
=
H1

H
=

=
CURVE CARATTERISTICHE
PERFORMANCE CURVES L2 = =
PRESSIONE / PRESSURE - p (bar)

30 L1 L S
25
20 A M X
15 A1 S2
A

A
10
A1

5
0

H4
10 20 30 40 50 60 H5
PORTATA / FLOW - Q (l/min)
L5 L4
Corpo in acciaio / Steel body
A060471.25.00 93.5 29.5 41 34.5 41 82 39.5 38 10 50 38 28 11.5 28 13 M6x50 OR 3056 13.95x2.62
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole a centro centre spools. To be connected
aperto in neutro. Collegare as shown. The valve allows:
allimpianto come da schema. free ow from A to A1,
La valvola permette: usso libero to hold the load with spool
da A verso A1, sostentamento in neutral position or with
del carico con distributore in the pump not running,
neutro o a pompa ferma, controllo controlled movement when
del movimento di discesa del pilot pressure is applied,
carico a seguito del pilotaggio relief function against
della valvola pilotaggio, protezione overpressure in the cylinder.
da sovrapressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
A 1/2"G
A060471.25.00 4.25:1 100-420 bar 400 bar 195 bar/turn 60 l/min 420 bar A1 8.5 1.4 Kg
B, X1, X2, M 1/4"G
Pag. 06.09.05B

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

L5 L4
2
C2 M3
V2

H1

H
K1
K1 M2

1 1 L3 L2

H2
2
~L1 L
V1 L7
D (n.4) = =

C1 V2

S1
D1

=
C2
p (bar)

S2
CURVE CARATTERISTICHE

S
=
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20 L6
HEX17 O-RING
15 V2 C2 L8

H4
10 C2 V2
HEX5

H3
0 10 20 30 40 50 60
HEX4
PORTATA / FLOW - Q (l/min)
HEX14 L9

Corpo in alluminio / Aluminium body


106 ~50 62 21 72.5 19.5 52 30 83 92 59 28 14.5 42.5 14.5 60 26.5 30 8.5 9 OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 L7 L8 L9 H H1 H2 H3 H4 S S1 S2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with
per distributori con spole a open centre spools. To be
centro aperto in neutro. connected as shown. The
Collegare allimpianto come da valve allows: free ow from
schema. La valvola permette: V2 to C2, to hold the load
usso libero da V2 verso C2, with spool in neutral position
sostentamento del carico or with the pump not running,
con distributore in neutro controlled lowering movement
o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico tramite il pilotaggio overpressure in the cylinder.
della valvola, protezione da
sovrappressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Setting Increase Flow Pressure
- 1 100-350 bar 270 bar 100 bar/turn V1,V2,C1,K 3/8"G
B060371.02.00 60 l/min 350 bar 1.2 kg
4.3:1 2 100-350 bar 310 bar 135 bar/turn M2,M3 1/4"G
Pag. 06.09.05C

Valvola di bilanciamento semplice eetto, serie 190 angiabile


Flangeable single overcenter valve "210 series"

LOAD
L1 L X

C2 C1
L4 L5

M V2 V1

V1

=
C2 C1

H1
H
=
V2
V2 V1

M
V2 V1

H2
L6
p (bar)

CURVE CARATTERISTICHE L3
PERFORMANCE CURVES
40 O-RING
PRESSIONE / PRESSURE -

D
30
V2 V1
20
V2

S
10 C2
C2
V2 C2 C1
0 L2 D1 D1
20 40 60 80 100

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


147 44 27 119.5 46.5 92 65.5 34.5 65 38 4.9 26 max. 8.5 9 OR 3056 13.95x2.62
L L1 L2 L3 L4 L5 L6 S H H1 H2 X D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from V2 to C2;
da schema. La valvola to hold the load with spool
permette: usso libero in neutral position or with
da V2 verso C2; sostentamento the pump not running;
del carico con distributore in controlled lowering movement
neutro o a pompa ferma; controllo when pilot pressure is applied,
del movimento di discesa relief function against
CODICE ORDINAZIONE SEALING ORDERING del carico tramite il pilotaggio overpressure in the cylinder.
PIOMBATURA CODE della valvola, protezione
916003 da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2 1/2"G
A060481.07.00 4.2:1 200-380 bar 370 bar 135 bar/turn 90 l/min 380 bar 2.36 kg
M 1/4"G
Pag. 06.09.06

Valvola di bilanciamento semplice eetto angiabile con anti-shock


Flangeable single overcenter valve with anti-shock

C L4 L3

M V
2 Valve1
T

0.7

H1
0.7
Pil Valve2
1
F T

H4
V
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
30
PRESSIONE / PRESSURE -

25 C F

H
M
H7

20
15 V
C C
10 V

H2
Pil

H8
5
H6
H5

H3
0 10 20 30 40 50 60 70 80
L2 L1 S2
PORTATA / FLOW - Q (l/min)
S1 S
L5 L
Corpo in acciaio / Steel body
A060471.19.00 70 38 5 33 24 22 39.5 4.8 28.5 94 82 43 13 13 10 24 38 36
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 H6 H7 H8

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows:
da schema. La valvola permette: free ow from V to C,
usso libero da V verso C, to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump not running,
o a pompa ferma, controllo controlled movement
del movimento di discesa when pilot pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da In the valve there's also
sovrappressioni nel cilindro. the anti-shock function
Nella valvola stata aggiunta between cylinder
la funzione di anti-shock and the valve itself,
fra cilindro e valvola, with download to the tank.
con scarico al serbatoio.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
1 400 bar 325 bar V 1/2"G
A060471.19.00 3.6:1 150-450 bar 80 l/min 500 bar T 3/8"G 2.2 kg
2 440 bar 144 bar Pil, F, M 1/4"G
Pag. 06.09.06A
Valvola di bilanciamento semplice eetto angiabile con anti-shock
Flangeable single overcenter valve with anti-shock

Valve1 L3 L4 L5
C V
M
2 HEX30
T

0.7

0.7
Pil HEX24 Valve2
1 T

H2
F
V

HEX19

H3
p (bar)

CURVE CARATTERISTICHE F
PERFORMANCE CURVES

X
H8

30

H
C
PRESSIONE / PRESSURE -

25
20 M
H6
H7

H1
15 C C
V
10
H5

5 Pil
S3
0 S2 H4 L7 L2 L6
10 20 30 40 50 60 70 80
S1 L1 L
PORTATA / FLOW - Q (l/min) S

Corpo in acciaio / Steel body


A060491.12.00 85 17 43 21 22 16 4.5 2 40 29 23 11 97 42 137 68 10.5 16 26 5 16 M22x1.5
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 H8 X

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come da free ow from V to C, to hold
schema. La valvola permette: the load with spool in neutral
usso libero da V verso C, position or with the pump not
sostentamento del carico con running, controlled lowering
distributore in neutro o a pompa movement when pilot pressure is
ferma, controllo del movimento applied, relief function against
di discesa del carico tramite overpressure in the cylinder.
il pilotaggio della valvola, In the valve there's also the
protezione da sovrappressioni anti-shock function between
nel cilindro. Nella valvola stata cylinder and the valve itself,
aggiunta la funzione di with outlet to the tank.
anti-shock fra cilindro e valvola,
con scarico al serbatoio.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max


SETTING INCREASE Max Flow PRESSURE Port Size Weight
V 1/2"G
3.6:1 1 150-450 bar 360 bar 325 bar/turn
A060491.12.00 80 l/min 500 bar T 3/8"G 2.8 kg
- 2 200-400 bar 380 bar 105 bar/turn Pil, F, M 1/4"G
Pag. 06.09.07

Valvola di bilanciamento semplice eetto angiabile serie 275


Flangeable single overcenter valve "275 series"

C2 M
11 191 59,5
P P
136
0.5 F(4 L HEX32
+4 = =
for
i)
C3 C3 M

14
V2 V2 V2

S
S1
=

S2
L1
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES L2
36 L3
30
PRESSIONE / PRESSURE -

171
V2
24 L4
C2 F1
18 C2 (n.4 = =
O-RING
)
12 V2

L5
6

=
H1

H
C2
0

=
70 140 210 280 350
PORTATA / FLOW - Q (l/min)
P C3 V2
100
Corpo in acciaio / Steel body
A068255.03.00 23.8 16 47 132 23.8 39.5 79.5 50.8 40 79 50.8 M10 10.5 4093 23.39x3.53
A068455.03.00 27.8 16 47 132 27.8 39.5 79.5 57.2 40 79 57.2 M12 12.5 4131 32.92x3.53
A068555.03.00 31.8 17.5 43.5 136 31.8 49.5 99.5 66.7 50 99 66.7 M14 15 4143 36.09x3.53
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 F F1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with open
con spole a centro aperto in neutro. centre spools. To be connected
Collegare allimpianto come as shown. The valve allows:
da schema. La valvola permette: free ow from V2 to C2;
usso libero da V2 verso C2; to hold the load with spool
sostentamento del carico in neutral position
con distributore in neutro or with the pump not running;
o a pompa ferma; controllo controlled movement
del movimento di discesa del carico when pilot pressure is applied,
a seguito del pilotaggio relief function against
della valvola pilotaggio, protezione overpressure in the cylinder.
da sovrappressioni nel cilindro. Port M is available only
La presa manometrica M for the code A068255.03.00.
disponibile solo per il codice
A068255.03.00.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max


Max Flow Pressure Port Size Weight
Range Setting Increase
V2, C2 3/4" SAE6000
A068255.03.00 6:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 9 kg
C3, P, M 1/4"G
V2, C2 1" SAE6000
A068455.03.00 6:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 9 kg
C3, P 1/4"G
V2, C2 1"1/4 SAE6000
A068555.03.00 6:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 13.5 kg
C3, P 1/4"G
Pag. 06.09.08

Valvola di bilanciamento semplice eetto angiabile serie 275


Flangeable single overcenter valve "275 series"

34 191 59,5
C2 M
136
P P
F(4 L HEX32
+4 = =

14
0.5 for
i)
M
C3 C3 V2

=
S1
V2 V2

S
S2
=
L1
CURVE CARATTERISTICHE
p (bar)

L2
PERFORMANCE CURVES
L3
36 171
30 L4
PRESSIONE / PRESSURE -

F1
V2 (n.4
) = =
24
C2 C2
18

L5
V2

=
12

H1

H
C2
6

=
0 70 140 210 280 350 V2
P C3
PORTATA / FLOW - Q (l/min) 100
O-RING
Corpo in acciaio / Steel body
A068255.04.00 23.8 16 47 132 23.8 39.5 79.5 50.8 40 79 50.8 M10 10.5 4093 23.39x3.53
A068455.02.00 27.8 16 47 132 27.8 39.5 79.5 57.2 40 79 57.2 M12 12.5 4131 32.92x3.53
A068555.03.00 31.8 17.5 43.5 136 31.8 49.5 99.5 66.7 50 99 66.7 M14 15 4143 36.09x3.53
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 F F1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata per suggested for use with
distributori con spole a centro open centre spools. To be
aperto in neutro. Collegare connected as shown.
allimpianto come da schema. The valve allows: free ow
La valvola permette: usso libero from V2 to C2; to hold
da V2 verso C2; sostentamento the load with spool
del carico con distributore in neutral position
in neutro o a pompa ferma; or with the pump not
controllo del movimento di running; controlled
discesa del carico a seguito movement when pilot
del pilotaggio della valvola pressure is applied,
pilotaggio, protezione da relief function against
sovrappressioni nel cilindro. overpressure in the cylinder.
La presa manometrica M Port M is available only
disponibile solo per il codice for the code A068255.04.00.
A068255.04.00.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max


Max Flow Pressure Port Size Weight
Range Setting Increase
V2, C2 3/4" SAE6000
A068255.04.00 13:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 9 kg
C3, P, M 1/4"G
V2, C2 1" SAE6000
A068455.02.00 13:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 9 kg
C3, P 1/4"G
V2, C2 1"1/4 SAE6000
A068555.02.00 13:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar 15 kg
C3, P 1/4"G
Pag. 06.10.01

Valvola di bilanciamento semplice eetto, serie 165 CC angiabile


Flangeable single overcenter valve "165 CC series"

F L5 L S
L2 L3
C1 S C2
Y X Y
SFIATO/ A1 S C2
AIR BLEED

=
A1 A B

=
C1

H1

H
=
p (bar)

=
CURVE CARATTERISTICHE
PERFORMANCE CURVES HEX17
25 Y A B Y
PRESSIONE / PRESSURE -

20 L4
C1 L1 L6
15 A
A
10 C1 D1 (n.4) D O-RING

=
0
10 20 30 40 50 60

L7
=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


109 52 37 30 19.5 52 39 30 55 30 16 max. 9 8.5 1/4"G 1/4"G OR 3043 10.77x2.62
109 52 37 30 19.5 52 39 30 55 30 16 max. 9 8.5 1/4"G 3/8"G OR 3043 10.77x2.62
109 52 37 30 19.5 52 39 35 65 30 16 max. 9 8.5 1/4"G 1/2"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 L7 H H1 S D D1 X Y O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with closed
con spole centro chiuso in neutro. center spools in neutral position.
Collegare allimpianto come da To be connected as shown
schema. La valvola permette: usso neutral. The valve allows:
libero da A verso C1, sostentamento free ow from A to C1, to hold
del carico con distributore in neutro the load position with spool
o a pompa ferma, controllo in neutral position or with
del movimento di discesa del carico the pump not running,
a seguito del pilotaggio della controlled movement when
valvola pilotaggio, protezione pilot pressure is applied, relief
da sovrappressioni nel cilindro, function against overpressure
se sullelemento del distributore in the cylinder when an auxiliary
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice di relief valve is tted in the
PIOMBATURA CODE pressione ausiliaria, da tarare almeno spool valve and set at least
916001 15 bar in meno rispetto alla valvola. 15 bar lower than the valve.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060276.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060276.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060276.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060376.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060376.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060376.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060476.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060476.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060476.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
Pag. 06.10.01A

Valvola di bilanciamento semplice eetto,serie 140 CC angiabile


Flangeable single overcenter valve "140 CC series"

HEX24
C2 C1
HEX24

H1
H
L3
L2
air bleed
L1 L
V2
F
)
V2 V1 O-RING = = n4
D(

CURVE CARATTERISTICHE
PERFORMANCE CURVES

=
C2

S1
PRESSIONE / PRESSURE - p (bar)

S
35

=
S2

30

25
V2

20
L4

15
C2

10 C2
5 V2

H2
H1
0
5 10 15 20 25 30 35 40
L3
PORTATA / FLOW - Q (l/min) L2

Corpo in acciaio / Steel body


A060376.10.00 96 46 80.5 17.5 48.5 50 30 25 34.5 14.5 17.5 30 6.5 OR 3043 10.78x2.62
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 F D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve, suggested


eetto, consigliata per distributori for use with closed center spools
con spole centro chiuso in neutro. in neutral position. To be
Collegare allimpianto come da connected as shown neutral.
schema. La valvola permette: usso The valve allows: free ow from
libero da V2 verso C2, sostentamento V2 to C2, to hold the load position
del carico con distributore in neutro with spool in neutral position
o a pompa ferma, controllo or with the pump not running,
del movimento di discesa del controlled movement when
carico a seguito del pilotaggio pilot pressure is applied, relief
della valvola pilotaggio, protezione function against overpressure
da sovrappressioni nel cilindro, in the cylinder when an auxiliary
se sullelemento del distributore relief valve is tted in the spool
montata una valvola limitatrice valve and set at least 15 bar
di pressione ausiliaria tarata lower than the valve.
15 bar in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2-C1 3/8"G
A060376.10.00 4.1:1 100-350 bar 300 bar 70 bar/turn 40 l/min 500 bar X kg
C2 6
Pag. 06.10.01B

Valvola di bilanciamento semplice eetto, serie 165 CC angiabile


Flangeable single overcenter valve "165 CC series"

F L1 L
L2
C2 M M C1 L3
HEX5
L4
HEX17 V2 M C1

=
=
V2 V1 C2

H1
V2

H
=

=
V2 M V1
SFIATO/ = =
p (bar)

H2
CURVE CARATTERISTICHE AIR BLEED L5
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

D1 (n.4) D O-RING
20
15 A
10 C1 C1

=
A
5

S
=
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060376.08.00 100 ~47 86 52 20.5 30 30 45 30 5 9 8.5 OR 3043 10.77x2.62
COD. L L1 L2 L3 L4 L5 S H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole centro with closed center spools
chiuso in neutro. Collegare in neutral position.
allimpianto come da schema. To be connected as shown
La valvola permette: neutral. The valve allows:
usso libero da A verso C1, free ow from A to C1,
sostentamento del carico to hold the load position
con distributore in neutro with spool in neutral position
o a pompa ferma, controllo or with the pump not running,
del movimento di discesa controlled movement
del carico a seguito del when pilot pressure is applied,
pilotaggio della valvola relief function against
pilotaggio, protezione da overpressure in the cylinder
sovrappressioni nel cilindro, when an auxiliary relief
se sullelemento del distributore valve is tted in the
montata una valvola spool valve and set
CODICE ORDINAZIONE SEALING ORDERING limitatrice di pressione ausiliaria, at least 15 bar
PIOMBATURA CODE da tarare almeno 15 bar lower than the valve.
916005 in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1 3/8"G
A060376.08.00 4.3:1 100-350 bar 300 bar 160 bar/turn 45 l/min 500 bar 0.95 kg
M 1/4"G
Pag. 06.10.01C

Valvola di bilanciamento semplice eetto, serie 210 CC angiabile


Flangeable single overcenter valve "210 CC series"

L1 X
F
L
S C1 C2 L2 L3
HEX24
A1 C2

H2
=
A B C1

H1
H
=
H3
p (bar)

CURVE CARATTERISTICHE A S B L4
PERFORMANCE CURVES L5
PRESSIONE / PRESSURE -

25 L6
20
D1 (n.4) D O-RING
15
A
10 C1
5 C1
A

=
S
0 20 40 60 80 100 120

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060476.14.00 141 187 40 38.5 18.5 58.5 102 39.5 60 40 10 30 22 max. 12 10.5 OR 3068 17.13x2.62
A060476.15.00 141 187 40 38.5 18.5 58.5 102 39.5 60 40 10 30 22 max. 12 10.5 OR 3068 17.13x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 X D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. position. To be connected
Collegare allimpianto come as shown neutral.
da schema. La valvola permette: The valve allows:
usso libero da A verso C1, free ow from A to C1,
sostentamento del carico to hold the load position
con distributore in neutro with spool in neutral position
o a pompa ferma, controllo or with the pump not running,
del movimento di discesa controlled movement when
del carico a seguito del pilot pressure is applied,
pilotaggio della valvola relief function against
pilotaggio, protezione da overpressure in the cylinder
sovrappressioni nel cilindro, when an auxiliary
se sullelemento del distributore relief valve is tted
montata una valvola in the spool valve and set
limitatrice di pressione ausiliaria, at least 15 bar lower
CODICE ORDINAZIONE SEALING ORDERING da tarare almeno 15 bar than the valve.
PIOMBATURA CODE in meno rispetto alla valvola. M =pressure gauge port
916013 M = attacco manometro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, A1, B, C2 1/2"G
A060476.14.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.4 kg
S 1/4"G
A, A1, B, C2 1/2"G
A060476.15.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.4 kg
S 1/4"G
Pag. 06.10.02

Valvola di bilanciamento semplice eetto, serie 165 CC angiabile


Flangeable single overcenter valve "165 CC series"
F
L5 L S
L2 L3
C1 S C2
Y X Y
SFIATO/
AIR BLEED A1 S B1

=
C1 C2

=
A1 A B B1

H1

H
=

=
p (bar)

CURVE CARATTERISTICHE HEX17


PERFORMANCE CURVES A Y Y B
25 L4
PRESSIONE / PRESSURE -

20 L1 L6
15 A C1
D
D1 (n.4) O-RING
10 C1 A

=
L7
0 10 20 30 40 50 60

=
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


109 55 37 36 19.5 52 39 30 55 30 16 max. 9 8.5 1/4"G 1/4"G OR 3043 10.77x2.62
109 55 37 36 19.5 52 39 30 55 30 16 max. 9 8.5 1/4"G 3/8"G OR 3043 10.77x2.62
109 55 37 36 19.5 52 39 35 65 30 16 max. 9 8.5 1/4"G 1/2"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 L7 H H1 S D D1 X Y O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto, consigliata per distributori suggested for use with closed
con spole centro chiuso in neutro. center spools in neutral position.
Collegare allimpianto come da To be connected as shown neutral.
schema. La valvola permette: usso The valve allows: free ow
libero da A verso C1, sostentamento from A to C1, to hold the load
del carico con distributore in neutro position with spool in neutral
o a pompa ferma, controllo position or with the pump not
del movimento di discesa del carico running, controlled movement
a seguito del pilotaggio della valvola when pilot pressure is applied,
pilotaggio, protezione relief function against
da sovrappressioni nel cilindro, overpressure in the cylinder
se sullelemento del distributor when an auxiliary relief valve
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice di is tted in the spool valve
PIOMBATURA CODE pressione ausiliaria, da tarare almeno and set at least 15 bar
916001 15 bar in meno rispetto alla valvola. lower than the valve.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A060286.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060286.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060286.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 20 l/min 500 bar 1/4"G 1.35 kg
A060386.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060386.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060386.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.3 kg
A060486.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060486.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
A060486.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 1.7 kg
Pag. 06.10.02A

Valvola di bilanciamento semplice eetto, serie 210 CC angiabile


Flangeable single overcenter valve "210 CC series"

F L1
L L2
S C1 C2
L3 L4
SFIATO/
AIR BLEED
A1 B1

=
A B

=
C1 C2

H2

H
=
p (bar)

=
CURVE CARATTERISTICHE A S B
PERFORMANCE CURVES
HEX24 L5

H1
25 L6
PRESSIONE / PRESSURE -

20 L7
15 A D
D1 (n.4) O-RING
10 C1
C1
5 A

=
0 20 40 60 80 100 120

S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
A060486.14.00 141 187 17.4 40 38.5 18.5 58.5 102 39.5 60 4.5 40 12 10.5 OR 3068 17.13x2.62
A060486.15.00 141 187 17.4 40 38.5 18.5 58.5 102 39.5 60 4.5 40 12 10.5 OR 3068 17.13x2.62
COD. L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole centro center spools in neutral
chiuso in neutro. Collegare position. To be connected
allimpianto come da schema. as shown neutral.
La valvola permette: The valve allows:
usso libero da A verso C1, free ow from A to C1,
sostentamento del carico to hold the load position
con distributore in neutro with spool in neutral position
o a pompa ferma, controllo or with the pump not running,
del movimento di discesa controlled movement
del carico a seguito when pilot pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione overpressure in the cylinder
da sovrappressioni nel cilindro, when an auxiliary relief valve
se sullelemento del distributore is tted in the spool valve
montata una valvola and set at least 15 bar
CODICE ORDINAZIONE SEALING ORDERING limitatrice di pressione lower than the valve.
PIOMBATURA CODE ausiliaria, da tarare almeno 15
916013 bar in meno rispetto alla valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A, A1, B, B1 1/2"G
A060486.14.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 500 bar 2.4 kg
S 1/4"G
A, A1, B, B1 1/2"G
A060486.15.00 8:1 150-350 bar 350 bar 82 bar/turn 120 l/min 500 bar 2.4 kg
S 1/4"G
Pag. 06.10.03

Valvola di bilanciamento semplice eetto, serie 210 CC angiabile


Flangeable single overcenter valve "210 CC series"
HEX24
F

S C1 C2

A A1

S
C1

L
S

=
A1 A B1 B

L3

L5
=
C2

L1
B B1

L4
L2
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25
HEX13 HEX10
PRESSIONE / PRESSURE -

20 H
15 O-RING = =
A
10 F
C1
C1
5 A

=
0

S1
25 50 75 100 125 150

=
PORTATA / FLOW - Q (l/min)
D n.4
H1 S2
Corpo in acciaio / Steel body
A060686.01.00 147 43 21 40 44 107 193 39.5 80 40 4.9 12 10.5 OR 3068 17.12x2.62
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 F D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with closed
per distributori con spole center spools in neutral
centro chiuso in neutro. position. To be connected as
La valvola permette: shown neutral. The valve allows:
usso libero da A verso C1, free ow from A to C1, to hold
sostentamento del carico the load position with spool
con distributore in neutro in neutral position or with
o a pompa ferma, controllo the pump not running,
del movimento di discesa controlled movement when
del carico a seguito del pilot pressure is applied, relief
pilotaggio, per la protezione function against overpressure
da sovrapressioni consigliato in the cylinder when an auxiliary
CODICE ORDINAZIONE SEALING ORDERING montare una valvola limitatrice relief valve is tted in the spool
PIOMBATURA CODE di pressione tarata a 15 bar valve and set at least 15 bar
916013 in meno rispetto all'overcentre. lower than the valve.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A-B 3/4"G
A060686.01.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3.1 kg
S 1/4"G
Pag. 06.10.04

Valvola di bilanciamento semplice angiabile serie 190 CC


Flangeable single overcenter valve "190 CC series"

F2
F

=
MX C1 C2

S
=
F1 F
air bleed
A1 B1
L5 L6
A B 4)
D (n

=
=
H2

H
CURVE CARATTERISTICHE

=
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

=
40
35
30 O-RING

H1
L3 L4
25
L2 L L1
20
A
15
10 C1
C1
A

=
5
0
15 30 45 60 75 90

=
PORTATA / FLOW - Q (l/min)
F1 F

Corpo in acciaio / Steel body


A060476.17.00 118 9 49.5 47 36 62 39 34.5 65 4.5 30 71.5 28.5 62 8.5 OR 3043 10.78x2.62
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 F F1 F2 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve, suggested


eetto, consigliata per distributori for use with closed center spools
con spole centro chiuso in neutro. in neutral position. To be connected
Collegare allimpianto come da as shown neutral. The valve allows:
schema. La valvola permette: usso free ow from A to C1, to hold
libero da A verso C1, sostentamento the load position with spool
del carico con distributore in neutro in neutral position or with the pump
o a pompa ferma, controllo not running, controlled movement
del movimento di discesa del carico when pilot pressure is applied,
a seguito del pilotaggio, protezione relief function against overpressure
da sovrappressioni nel cilindro, in the cylinder when an auxiliary
se sullelemento del distributore relief valve is tted in the spool
CODICE ORDINAZIONE SEALING ORDERING montata una valvola limitatrice valve and set at least 15 bar
PIOMBATURA CODE di pressione ausiliaria tarata 15 bar lower than the valve.
916001 in meno rispetto alla overcentre.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
A-B-A1-B1 1/2"G
A060476.17.00 4.25:1 100-350 bar 350 bar 120 bar/turn 90 l/min 350 bar C1-C2 9 1.9 kg
C3 1/8"G
Pag. 06.12.01

Valvola di bilanciamento semplice eetto, serie BP


Single overcenter valve "BP series"

C2 C1 L1 L
L2 L3

HEX5 L6 L5

H1
V2 V1 HEX17

C2 C1

=
CURVE CARATTERISTICHE
PERFORMANCE CURVES

H
p (bar)

25
20
15 V2

=
10 C2
PRESSIONE / PRESSURE -

C2 V2 V1
5
V2
0 L4 L3
25 50 75 100
D (n.2)
25
20
15 V2

=
10 C2 C2

S
5
V2

=
0 10 20 30 40
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B060461.02.00 110 ~54 52.5 18 71.5 46 54 35 70 10 8.5
B060661.01.00 130 ~58 67.5 22 86 50 70 45 90 10 10.5
COD. L L1 L2 L3 L4 L5 L6 S H H1 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use
per distributori con spole with open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from A to C1, to hold the load
usso libero da A verso C1, with spool in neutral position
sostentamento del carico or with the pump not running,
con distributore in neutro controlled movement
o a pompa ferma, controllo when pilot pressure
del movimento di discesa is applied, relief function
del carico a seguito del against overpressure
pilotaggio della valvola in the cylinder.
pilotaggio, protezione The control valve inside,
CODICE ORDINAZIONE SEALING ORDERING da sovrappressioni is in cartridge style .
PIOMBATURA CODE nel cilindro. La valvola
916005 di controllo a cartuccia.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B060461.02.00 10:1 100-350 bar 210 bar 95 bar/turn 40 l/min 350 bar 1/2"G 0.9 kg
B060661.01.00 10:1 100-350 bar 210 bar 155 bar/turn 100 l/min 350 bar 3/4"G 1.6 kg
Pag. 06.13.01

Valvola di bilanciamento semplice eetto ad area dierenziale zero, serie 190 DZ


Single overcenter valve with zero dierential area "190 DZ series"

C2
L1 L L2
L3
M HEX5 L4
1 2
HEX17 C2

H3
Pil
2

X
V2
M
A B

H2
H
H4
p (bar)

CURVE CARATTERISTICHE

H1
PERFORMANCE CURVES Pil
1
20
PRESSIONE / PRESSURE -

HEX24 V2 L5
15
D
10 C2
5 V2

=
S
0 15 30 45 60 75 90

=
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B060461.01.00 100 ~49 10 52.5 33 83 35 80 27 30 10 41 7 1/4"G
COD. L L1 L2 L3 L4 L5 S H H1 H2 H3 H4 D X

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto. La valvola the control valve
di controllo ad area dierenziale has no dierential area
zero e la sua apertura non dipende and its opening is not eected
dalla pressione del carico, ma solo by the pressure induced
dalla pressione di pilotaggio. by the load, but it is related
Consigliata per distributori only to the pilot pressure.
con spole a centro chiuso Suggested for use with closed
in neutro. Collegare allimpianto centre spools. To be connected
come da schema. La valvola as shown. The valve allows:
permette: usso libero da V2 free ow from V2 to C2,
verso C2, sostentamento to hold the load with spool
del carico con distributore in neutral position or with
in neutro o a pompa ferma, the pump not running,
controllo del movimento controlled movement
di discesa del carico a seguito when pilot pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione da overpressure in the cylinder,
CODICE ORDINAZIONE SEALING ORDERING sovrappressioni nel cilindro, when an auxiliary relief valve
PIOMBATURA CODE
se sullelemento distributore is tted in the spool valve.
916005 montata una valvola imitatrice
di pressione.

Codice Taratura Standard Incremento Portata Pressione Dimensione Porte Peso


Ordinazione per Giro Massima Max
Pressure Max
Ordering Code Standard Setting Max Flow Port Size Weight
Increase Pressure
1 25-30 bar 7.2 bar/turn C2, V2 1/2"G
B060461.01.00 90 l/min 500 bar 1.1 kg
2 380 bar 110 bar/turn Pil 3/8"G
Pag. 06.13.02
Valvola di bilanciamento semplice eetto ad area dierenziale zero,
serie 190 DZ, angiabile
Flangeable single overcenter valve with zero dierential area "190 DZ series"

M C2 C1 L2 L L1
1 HEX24 L3 L4

H2
1
2

S1
H3
0.5

S
C2 C1

S2
HEX5
M

S3
H1 H
V2 V1 2 HEX17
F
CURVE CARATTERISTICHE
p (bar)

F1 D(n4)
PERFORMANCE CURVES
40
V2 V1
PRESSIONE / PRESSURE -

F3
F2

30
V2
20 C2 C2 C1
C2
10
V2
O-RING

0 15 30 45 60 75 90

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B0060486.01.00 150 ~4 ~54 66 54 80 38 32 ~5 92 47 29 62 120 27.5 34.5 17 8.5 OR 13.95x2.62
COD. L L1 L2 L3 L4 S S1 S2 S3 H H1 H2 H3 F F1 F2 F3 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a semplice Single overcenter valve,


eetto. La valvola di controllo the control valve has no
ad area dierenziale zero e la sua dierential area and its opening
apertura non dipende dalla pressione is not eected by the pressure
del carico, ma solo dalla pressione induced by the load, but it is
di pilotaggio. Consigliata per related only to the pilot pressure.
distributori con spole a centro chiuso
Suggested for use with closed
in neutro. Collegare allimpianto
centre spools. To be connected
come da schema. La valvola permette:
usso libero da V2 verso C2, as shown. The valve allows:
sostentamento del carico con free ow from V2 to C2, to hold
distributore in neutro o a pompa the load with spool in neutral
ferma, controllo del movimento position or with the pump not
di discesa del carico a seguito running, controlled movement
del pilotaggio della valvola pilotaggio, when pilot pressure is applied,
protezione da sovrappressioni relief function against
CODICE ORDINAZIONE SEALING ORDERING nel cilindro, se sullelemento overpressure in the cylinder,
PIOMBATURA CODE distributore montata una when an auxiliary relief valve
valvola imitatrice di pressione. is tted in the spool valve.
916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
30 bar V1-V2 1/2"G
- 12.5-30 bar 1 cracking 8 bar/turn
B060486.01.00 90 l/min 350 bar M 1/4"G 1.1 kg
- 100-400 bar 2 380 bar 110 bar/turn C1-C2 9
Pag. 06.13.03
Valvola di bilanciamento semplice eetto ad area dierenziale zero,
serie 190 DZ , angiabile
Flangeable single overcenter valve with zero dierential area "190 DZ series"

M C2 C1 L2 L L1
L3 L4

H2
C2 C1

=
2 1

H1
H3
0.5

H
HEX5
HEX17 M
2

H4
V2 V1 = =
p (bar)

L6 L5
CURVE CARATTERISTICHE
PERFORMANCE CURVES
L7
40
PRESSIONE / PRESSURE -

HEX24 L8
30 D(n6)
V2 V1
20
V2
10 C2
S

C2

S1
0 V2
20 40 60 80 100 C2 C1

PORTATA / FLOW - Q (l/min) O-RING

Corpo in acciaio / Steel body


150 ~4 ~54 66 54 92 47 120 27.5 80 38 29 62 ~5 34.5 17 8.5 OR 3056 13.95x2.62
L L1 L2 L3 L4 L5 L6 L7 L8 H H1 H2 H3 H4 S S1 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve.


semplice eetto. La valvola The control valve has no
di controllo ad area dierenziale dierential area and its opening
zero e la sua apertura non is not eected by the pressure
dipende dalla pressione del carico, induced by the load, but it is
ma solo dalla pressione di related only to the pilot pressure.
pilotaggio. Consigliata per Suggested for use with closed
distributori con spole a centro centre spools. To be connected
chiuso in neutro. Collegare as shown. The valve allows: free
allimpianto come da schema. ow from V2 to C2, to hold the
La valvola permette: usso libero load with spool in neutral position
da V2 verso C2, sostentamento or with the pump not running,
del carico con distributore in controlled lowering movement
neutro o a pompa ferma, controllo when pilot pressure is applied,
del movimento di discesa relief function against
del carico tramite il pilotaggio overpressure in the cylinder,
della valvola, protezione da when an auxiliary relief valve
sovrappressioni nel cilindro, is tted on the spool valve.
CODICE ORDINAZIONE SEALING ORDERING se sullelemento distributore
PIOMBATURA CODE montata una valvola
916005 limitatrice di pressione.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
30 bar V1-V2 1/2"G
- 12.5-30 bar 1 cracking 8 bar/turn
A060486.05.00 90 l/min 350 bar M 1/4"G 3.1 kg
- 100-400 bar 2 350 bar 110 bar/turn C1-C2 9
Pag. 06.13.04
Valvola di bilanciamento semplice eetto ad area dierenziale zero,
serie 210 Dz, angiabile
Flangeable single overcenter valve with zero dierential area "210 dz series"

C2 C1 2 HEX13
C1
M 0.5 HEX10
2
1 C2

H
H3

H1
P

H2
HEX24
1
V2 P V1
L5 V2 M V1
L3 L4
p (bar)

CURVE CARATTERISTICHE L2
PERFORMANCE CURVES
L L1
30

S1
HEX27
PRESSIONE / PRESSURE -

25 HEX17
C2 HEX5
20 P
15 V2 V2 C1
C2

=
10

S
5 V2

=
0 15 30 45 60 75 90 105 120 135 150
PORTATA / FLOW - Q (l/min) C2

S2
S3
D

Corpo in acciaio / Steel body


150 17.5 127 82 31.5 39 40 13.8 18.7 14.7 88 66 37 70 37.5
L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto. La valvola di the control valve has no
controllo ad area dierenziale dierential area and its opening
zero e la sua apertura non is not eected by the pressure
dipende dalla pressione induced by the load, but it is
del carico, ma solo dalla pressione related only to the pilot pressure.
di pilotaggio. Consigliata per Suggested for use with closed
distributori con spole a centro centre spools. To be connected
chiuso in neutro. Collegare as shown. The valve allows:
allimpianto come da schema. free ow from V2 to C2, to hold
La valvola permette: usso libero the load with spool in neutral
da V2 verso C2, sostentamento position or with the pump not
del carico con distributore in running, controlled lowering
neutro o a pompa ferma, movement when pilot
controllo del movimento di pressure is applied, relief function
discesa del carico tramite il against overpressure in the
pilotaggio della valvola, cylinder, when an auxiliary relief
protezione da sovrappressioni nel valve is tted in the spool valve.
CODICE ORDINAZIONE SEALING ORDERING cilindro, se sullelemento
PIOMBATURA CODE distributore montata una
916005 - 916013 valvola limitatrice di pressione.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
20 bar V1,V2 3/4"G
- 10-30 bar 1 cracking 9 bar/turn
A060696.01.00 150 l/min 420 bar C1,C2 3/4"G 3.85 kg
- 100-420 bar 2 420 bar 110 bar/turn M,P 1/4"G
Pag. 06.13.20

Valvola di bilanciamento semplice eetto angiabile serie 210


Flangeable single overcenter valve "210 series"

HEX24

H1
G

C1 C2

D1

D
H2
H
0.5
V1 C3 V2

H3 L4 L2 L3

V1 C3 V2

CURVE CARATTERISTICHE
PERFORMANCE CURVES

S
PRESSIONE / PRESSURE - p (bar)

42
V2

36
30 L L1
C2

24
SAE SEAL
18 F1

12 C2

S1
C1 C2
V2
=

6
0
24 48 72 96 120
=

PORTATA / FLOW - Q (l/min)


F

= =
L6 L5
Corpo in acciaio / Steel body
A060481.08.00 155 43 67 26 36 67 59 69 62 80 4.5 25 24 18.2 40.5 8.5 8.5 13.5
COD. L L1 L2 L3 L4 L5 L6 S S1 H H1 H2 H3 F F1 G D D1

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve, suggested


a semplice eetto, consigliata for use with open centre spools.
per distributori con spole a centro To be connected as shown.
aperto in neutro. Collegare The valve allows: free ow from
allimpianto come da schema. V2 to C2; to hold the load with
La valvola permette: usso libero spool in neutral position or with
da V2 verso C2; sostentamento the pump not running; controlled
del carico con distributore in neutro movement when pilot pressure
o a pompa ferma; controllo is applied, relief function against
del movimento di discesa del carico overpressure in the cylinder.
a seguito del pilotaggio della C3 brings to unlock brake.
CODICE ORDINAZIONE SEALING ORDERING valvola pilotaggio, protezione
PIOMBATURA CODE da sovrappressioni nel cilindro.
916013 Porta C3 per sblocca freno.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Code Range Setting Increase Flow Pressure
V1, V2 1/2"G
A060481.08.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 400 bar C3 1/4"G 6 kg
C1, C2 1/2"SAE6000
Pag. 06.13.21

Valvola di bilanciamento semplice eetto angiabile serie 275


Flangeable single overcenter valve "275 series"

V2 C3 V1
S2
)
D1 (n.8

0.5 D (n.8)

H1
V1 V2

H
C3

H2
S1 L4 L2 L3
C2 C1

S
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
36
30 L L1
PRESSIONE / PRESSURE -

V2 L7
24
C2 C2
18
V2

H3
12
C1 C2
6
==
H4

0
70 140 210 280 350
HEX32
PORTATA / FLOW - Q (l/min) = =
SAE SEAL
L6 L5

Corpo in acciaio / Steel body


A060881.01.00 198 59.5 110 26 36 72 84 57.2 69 24 12 100 4.5 25 74.1 27.8 12.5 19
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 H4 D D1

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with open
per distributori con spole a centre spools. To be connected
centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from V2 to C2;
da schema. La valvola permette: to hold the load with spool
usso libero da V2 verso C2; in neutral position or with
sostentamento del carico con the pump not running;
distributore in neutro o a controlled movement when
pompa ferma; controllo del pilot pressure is applied,
movimento di discesa del carico relief function against
a seguito del pilotaggio della overpressure in the cylinder.
valvola pilotaggio, protezione
da sovrappressioni nel cilindro.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max


Max Flow Pressure Port Size Weight
Range Setting Increase
V1, V2 1"G
A060881.01.00 6:1 250-500 bar 350 bar 94 bar/turn 350 l/min 500 bar C1, C2 1"SAE6000 9 kg
C3 1/4"G
Pag. 06.13.22

Valvola di bilanciamento semplice eetto, serie 210


Flangiabile angeable single overcenter valve "210 series"

L6 L5

H4
C1 C2
C2

H5 H6 H5

H3
0.5
C1

H4
L8 L7 O-RING

DR
L L1
H7
V1 C3 V2 D1 (n.2)

S1
S2
p (bar)

CURVE CARATTERISTICHE
DR

S
PERFORMANCE CURVES

S3
25
PRESSIONE / PRESSURE -

20
D (n.2)
15
V2
10
C2 C2 L3 L2
5
V2
0 V1 V2
20 50 60 80 100 120
H

PORTATA / FLOW - Q (l/min)


H1

C3
H2

L4

Corpo in alluminio / Aluminium body


B060671.01.00 130 43.5 76 20 57 42 15 32 20 69 10 19 24 60 41 25 32 14 19 22 51 10.5 17 OR 3087 22.22x2.62
COD. L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Single angeable overcenter


semplice con angiatura per valve for DANFOSS
motori idraulici DANFOSS OMS, OMSW and OMSS
OMS, OMSW, OMSS. Tramite machines.With an adapter
un adattatore a piastra pu plate it's available with ange
essere fornita con angiatura for OMT and OMR motors.
per motori OMT e OMR.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max


Max Flow Pressure Port Size Weight
Range Setting Increase
V1,V2 3/4"G
B060671.01.00 4:1 100-350 bar 350 bar 108 bar/turn 120 l/min 350 bar 1.55 kg
C3,DR 1/8"G
Pag. 06.13.23

Valvola di blocco bilanciata semplice serie 165 angiabile per motori idraulici
Dual overcenter valve "165 series",angeable for hydraulics motors

C2 C1 HEX4 HEX13

2 0.5 bar HEX10

S1
< 0.7 bar
HEX3

S
1 C2 C1

S2
C3

V2 V1
L7 L6

CURVE CARATTERISTICHE H1
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25

H6
H

20

H5
H2

15 V1 C1
V1
H3

10 C1
H4

5 L5
0 L4
10 20 30 40 50 60 L1
PORTATA / FLOW - Q (l/min) L3 L L2

Corpo in alluminio / Aluminium body


B060491.03.00 135 95 ~36.8 ~41.5 52 19 36 49 50 9.5 16 110 8 80 39 20 77 36
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 H4 H5 H6

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Single overcenter valve


semplice con bulloni per motori for danfoss motors OMR, OMP.
danfoss OMR, OMP.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
1 8.75:1 50-220 bar 210 bar 55 bar/turn V1-V2-C1-C2 1/2"G 2.5 kg
B060491.03.00 60 l/min 350 bar
2 - 7-15 10 bar 3 bar/turn C3 1/4"G
Pag. 06.13.24

Valvola di bilanciamento semplice eetto angiabile con cartuccia serie SM


Flangeable single overcenter valve with cartridge "SM series"

D (n4)

C1 C2

C2

L1

L3
L2
L

L3
F
C1
S1 S2
V1 V2
S
HEX4

H1
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

H
25
C1 C2
PRESSIONE / PRESSURE -

20
15 O-RING HEX13
G
V1
10
C1 V1
5
C1
V1
0 15 30 45 60
H2

PORTATA / FLOW - Q (l/min)


F
H3

H4
V2
G3
G2
G1

Corpo in alluminio / Aluminium body


B060381.12.00 88 26 36 40 88 27 36 45 11 66.5 25 26 14.5 63 56 30 8.5 OR 130 22.22x2.62
COD. L L1 L2 L3 S S1 S2 H H1 H2 H3 H4 G G1 G2 G3 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Single angeable overcenter valve


semplice con angiatura for DANFOSS motors OMP.
per motori DANFOSS OMP.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 3/8"G
B060381.12.00 4.25:1 100-350 bar 210 bar 106 bar/turn 55 l/min 350 bar 1.07 kg
F M10x1
Pag. 06.13.25

Valvola di bilanciamento semplice eetto angiabile con cartuccia serie SM


Flangeable single overcenter valve with cartridge "SM series"

L
L2 L1

C1 C2 L3 L3

H4
C1

H3
H1
H

H3
H2
F C2

D (n 2)
V1 V2
HEX13
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES HEX4

S
25
C2 C1
PRESSIONE / PRESSURE -

20
V1 O-RING
15
C1 C1 G2
10
V1 G3

G4
5
V2 F
G1

0 20 40 60 80
G

V1

Corpo in alluminio / Aluminium body


B060481.02.00 108 59 32 5 48 73 22 34 5 27.5 56 34 91 32 27.5 10.5 OR 130 22.22x2.62
COD. L L1 L2 L3 S H H1 H2 H3 H4 G G1 G2 G3 G4 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Single angeable overcenter


semplice con angiatura per valve for DANFOSS motors OMS.
motori DANFOSS OMS.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 1/2"G
B060481.02.00 4.25:1 100-350 bar 210 bar 106 bar/turn 80 l/min 350 bar 1.15 kg
F M10x1
Pag. 06.13.26

Valvola di bilanciamento semplice eetto, serie 165 angiabile


Flangeable single overcenter valve "165 series"

C2 C1 O-RING
L3

C3

S4
S3

S
S1
S4
V2 V1

S2
V2 C3 V1

L1 L2
CURVE CARATTERISTICHE
PERFORMANCE CURVES L
PRESSIONE / PRESSURE - p (bar)

HEX13
25
HEX4 D(n4)
20

15 V2

=
C2

H
10 C2

=
5 V2
L6
0 L5
10 20 30 40 50
L4
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060481.10.00 108 55 36 50.5 ~149.3 74 20.5 90 63 27 36 40 37 8.25 OR 3093 23.47x2.62
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S3 H D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Single angeable overcenter


semplice con angiatura per valve for danfoss motors OMR
motori Danfoss OMR, OMP OMP and white series HS, HP.
e white series HS e HR.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
V1-V2 1/2"G
A060481.10.00 4.25:1 100-350 bar 300 bar 135 bar/turn 50 l/min 300 bar C1-C2 9 2.5 kg
C3 1/8"G
Pag. 06.14.01

Valvola in linea per escavatori serie EMM 140 destra


Valve for earth moving machines "EMM 140 series" dx

LOAD
L3
L4

M
C2

H3
H5
M B

H2
C2 V2

H1
R
R A

H4

H
A
Pil

T V2 Pil

L1 L L2 HEX19

HEX24
HEX13
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
M
35 T
S
PRESSIONE / PRESSURE -

30 C2 V2
S2

25
V2

20
15 HEX4 D
C2

S1

10
5 C2 B
V2
0 5 10 15 20 25 30 35 40 45
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060350.01.00 107 ~26 49 56.5 43 35 25 17.5 65 50 31 8 68.5 14 8.5
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero with spool in neutral position
da V2 verso C2, il sostentamento or with the pump not running,
del carico con distributore controlled movement
in neutro o pompa ferma, when pilot pressure is applied,
controllo della discesa a valvola relief function against
pilotata e protezione contro overpressure in the cylinder.
sovrappressioni nel cilindro. T port must be connected
CODICE ORDINAZIONE SEALING ORDERING Lattacco T deve essere directly to the tank.
PIOMBATURA CODE collegato direttamente
916003 a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 3/8"G
A060350.01.00 40 l/min 500 bar Pil, T 1/4"G 1.8 kg
B 200-400 bar 350 bar 215 bar/turn M 1/8"G
Pag. 06.14.02

Valvola in linea per escavatori serie EMM 140 sinistra


Valve for earth moving machines "EMM 140 series" sx

LOAD

L4

H1
C2
M
M B

H5
H4
H3
R
V2 C2

H2
A
A

H
R
T V2 Pil Pil

L3

L2 L L1

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES HEX19 HEX24 HEX13 HEX4

35
30 M
PRESSIONE / PRESSURE -

25 T V2 C2
V2

20
S2

15
C2

10 D
S1

5 C2
V2 B
0
5 10 15 20 25 30 35 40 45

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060350.02.00 107 ~26 49 43 56.5 35 25 17.5 65 3.5 50 31 14 8 8.5
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero with spool in neutral position
da V2 verso C2, il sostentamento or with the pump not running,
del carico con distributore controlled movement
in neutro o pompa ferma, when pilot pressure is applied,
controllo della discesa a valvola relief function against
pilotata e protezione contro overpressure in the cylinder.
sovrappressioni nel cilindro. T port must be connected
CODICE ORDINAZIONE SEALING ORDERING Lattacco T deve essere directly to the tank.
PIOMBATURA CODE collegato direttamente
916003 a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 3/8"G
A060350.02.00 40 l/min 500 bar Pil, T 1/4"G 1.8 kg
B 200-400 bar 350 bar 215 bar/turn M 1/8"G
Pag. 06.14.03

Valvola in linea per escavatori serie EMM 190 destra


Valve for earth moving machines "EMM 190 series" dx

LOAD

L4

L5
C2
L6

H2
H3
M B M

H5

H1
A
C2 V2

H4
R A

H
T V2 Pil
Pil
p (bar)

CURVE CARATTERISTICHE L2 L L1
PERFORMANCE CURVES
35
HEX4 HEX13 HEX27 HEX22
30
PRESSIONE / PRESSURE -

25
V2

20 M
C2 V2 T
C2

15
S

10
S2

5
C2
V2 D (n.2)
0
S1

10 20 30 40 50 60 70 80 90 100
PORTATA / FLOW - Q (l/min) B

Corpo in acciaio / Steel body


A060450.01.00 130 54 ~24 35 69.5 52 30 35 25 17.5 70 34.5 8.5 3.5 53 16 8.5
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero the load with spool in neutral
da V2 verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa pressure is applied,
a valvola pilotata e protezione relief function against
contro sovrappressioni overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING nel cilindro. Lattacco T T port must be connected
PIOMBATURA CODE deve essere collegato directly to the tank.
916003 direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 1/2"G
A060450.01.00 100 l/min 500 bar Pil, T 1/4"G 2.5 kg
B 200-400 bar 350 bar 215 bar/turn M 1/8"G
Pag. 06.14.04

Valvola in linea per escavatori serie EMM 190 sinistra


Valve for earth moving machines "EMM 190 series" sx

LOAD
L3
L4
L5

H6
H1
M
C2

H4
M B

H3

H5
R
V2 C2

H2
A
A

H
R
Pil
T V2 Pil

L1 L L2

HEX4
p (bar)

CURVE CARATTERISTICHE HEX22 HEX27


PERFORMANCE CURVES HEX13
35
30
PRESSIONE / PRESSURE -

M
25 V2 C2
V2

T
S

20
S2
C2

15
10
C2 D (n.2)
S1

5
V2
0 B
10 20 30 40 50 60 70 80 90 100
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A060450.02.00 130 54 ~24 69.5 52 22 35 25 17.5 70 3.5 53 34.5 16 32 8.5 8.5
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero the load with spool in neutral
da V2 verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa pressure is applied,
a valvola pilotata e protezione relief function against
contro sovrappressioni overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING nel cilindro. Lattacco T T port must be connected
PIOMBATURA CODE deve essere collegato directly to the tank.
916003 direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 1/2"G
A060450.02.00 100 l/min 500 bar Pil, T 1/4"G 2.5 kg
B 200-400 bar 350 bar 215 bar/turn M 1/8"G
Pag. 06.14.05

Valvola in linea per escavatori serie EMM 210 destra


Valve for earth moving machines "EMM 210 series" dx

LOAD

L3
L4
C2

H1
L5
M B M

H6
R

H4
A

H5
H3
C2 V2

H2
T V2 Pil A

H
R
Pil
p (bar)

CURVE CARATTERISTICHE
L1 L L2
PERFORMANCE CURVES
30 HEX4
HEX13 HEX27 HEX22
PRESSIONE / PRESSURE -

25
20 V2
15 M
C2 C2 V2 T
S

10
5 C2
S2

V2
0 15 30 45 60 75 90 105 120 135 150
D (n.2)
S1

PORTATA / FLOW - Q (l/min) B

Corpo in acciaio / Steel body


A060650.01.00 145 ~25 55 81.5 64 37 40 25 20 80 4.5 61 38.5 20 40 12 11
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero the load with spool
da V2 verso C2, il sostentamento in neutral position or with
del carico con distributore the pump not running,
in neutro o pompa ferma, controlled movement
controllo della discesa when pilot pressure is applied,
a valvola pilotata e protezione relief function against
contro sovrappressioni overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING nel cilindro. Lattacco T T port must be connected
PIOMBATURA CODE deve essere collegato directly to the tank.
916003 direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 3/4"G
A060650.01.00 150 l/min 500 bar Pil, T 1/4"G 3.4 kg
B 200-400 bar 350 bar 215 bar/turn M 1/4"G
Pag. 06.14.06

Valvola in linea per escavatori serie EMM 210 sinistra


Valve for earth moving machines "EMM 210 series" sx

LOAD

L3
L4
C2
L5

H1
M B M

H6
R

H4
H3
A

H5
V2 C2

H2
Pil
T V2 Pil
A

H
R
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
L2 L L1
30
HEX13
PRESSIONE / PRESSURE -

25 HEX27
HEX22 HEX4
20 V2
15
C2

S2
10 T V2 M C2
C2

S
5
V2
0 15 30 45 60 75 90 105 120 135 150

PORTATA / FLOW - Q (l/min) D (n.2)

S1
B

Corpo in acciaio / Steel body


A060650.02.00 145 ~25 55 81.5 64 37 40 25 20 80 4.5 61 38.5 20 40 12 11
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero da V2 the load with spool in neutral
verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa pressure is applied,
a valvola pilotata e protezione relief function against
contro sovrappressioni overpressure in the cylinder.
CODICE ORDINAZIONE SEALING ORDERING nel cilindro. Lattacco T T port must be connected
PIOMBATURA CODE deve essere collegato directly to the tank.
916003 direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 7-19.5 bar 7.5 bar 3 bar/turn V2, C2 3/4"G
A060650.02.00 150 l/min 500 bar Pil, T 1/4"G 3.4 kg
B 200-400 bar 350 bar 215 bar/turn M 1/4"G
Pag. 06.15.01

Valvola in linea per escavatori serie EMM 190


Valve for earth moving machines "EMM 190 series"

LOAD L1 L

L2
C2 L3
E
E L4

H1
B

Pil A Pil T
T T
V2

H
V2 V2 E

H6
H2 Pil
H3

H4
C2 HEX24

H5
L5
O-RING
B
p (bar)

CURVE CARATTERISTICHE D (n.4)

S1
PERFORMANCE CURVES
= = Pil T V2
42 E A
36
V2
PRESSIONE / PRESSURE -

=
30 C2
=
C2

S3

24

S
18
=

=
12 C2
6 V2 E
F3 Pil T V2
0 24 48 72 96 120

S2
F2
PORTATA / FLOW - Q (l/min) F1 F

Corpo in acciaio / Steel body


127 3 112 87 66.5 27.5 60 25 4.5 40.5 59.5 5.5 29.5 26 25 13 41.5 175 4 155 18.2 8.5 OR 4075 18.64x3.53
L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 F F1 F2 F3 D O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato dai from the machine manipulators,
manipolatori di comando the valve allows: free ow
distributore e la valvola permette: from V2 to C2, to hold
il usso libero da V2 verso C2, the load with spool in neutral
il sostentamento del carico position or with the pump
con distributore in neutro not running, controlled
o pompa ferma, controllo movement when pilot pressure
della discesa a valvola pilotata is applied, relief function against
e protezione contro overpressure in the cylinder.
sovrappressioni nel cilindro. T port must be connected
Lattacco T deve essere collegato directly to the tank.
direttamente a scarico. Port E has to be connected
Lattacco E da collegare to the valve of the second
alla valvola sullaltro cilindroidi boom cylinder, can be used
sollevamento, pu servire as manual lowering emergency.
come emergenza manuale
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 4 bar/turn V2 1/2"G
A068155.01.00 120 l/min 500 bar C2 1/2"SAE6000 4 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.02

Valvola in linea per escavatori serie EMM 210


Valve for earth moving machines "EMM 210 series"

L1 L L2
LOAD
L3
L4
C2 L5
E
E

H1
= =
D1 (n.8)
B

Pil A Pil T V2

=
T T

H5

H
V2 V2 E

=
H2

H7
Pil
H3

H4
C2

H6
L7
L6
O-RING
B
p (bar)

CURVE CARATTERISTICHE D (n.4)


PERFORMANCE CURVES Pil T

S1
= = HEX24
35 V2
C2 E
PRESSIONE / PRESSURE -

30
V2

25
A

=
20
C2

15
S3

S
10
C2
=

5 V2

=
0 15 30 45 60 75 90 105120135150 E
PORTATA / FLOW - Q (l/min)
F3 Pil T V2
F2

S2
F1 F
Corpo in acciaio / Steel body
151 4.5 43 133 110 83 40 18.2 69 23 4.5 40.5 69 5.5 40 29 28 40.5 14.5 39.5 198 4 178 18.2 8.5 M8 OR 4075 18.64x3.53
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 F3 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine
dai manipolatori di comando manipulators, the valve allows:
distributore e la valvola free ow from V2 to C2,
permette: il usso libero to hold the load with spool
da V2 verso C2, il sostentamento in neutral position
del carico con distributore or with the pump not running,
in neutro o pompa ferma, controlled movement
controllo della discesa a valvola when pilot pressure is applied,
pilotata e protezione contro relief function against
sovrappressioni nel cilindro. overpressure in the cylinder.
Lattacco T deve essere collegato T port must be connected
direttamente a scarico. directly to the tank.
Lattacco E da collegare Port E has to be connected
alla valvola sullaltro cilindroidi to the valve of the secon
sollevamento, pu servire boom cylinder, can be
come emergenza manuale used as manual lowering
per abbassare il carico. emergency.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 4.9 bar/turn V2, C2 1/2"SAE6000
A068155.02.00 150 l/min 500 bar 6 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.03

Valvola in linea per escavatori serie EMM 210d


Valve for earth moving machines "EMM 210d series"

L1 L
LOAD L2
L3
D1 (n.8)
C2 L4

H1
E
E
B
T
A
V2
Pil Pil

H
T T

H6
V2 V2 E

=
H2

H7
Pil
H3

H4
C2

H5
= =
L5
O-RING L6
B
p (bar)

CURVE CARATTERISTICHE D (n.4) F4 HEX24

S1
PERFORMANCE CURVES = = Pil T V2
70
E A
60
PRESSIONE / PRESSURE -

V2

=
50
C2
=

40
C2

S3

S
30
20
=

C2

=
10 V2
0
E
25 50 75 100 125 150175200 225 250
Pil T V2
PORTATA / FLOW - Q (l/min) F3

S2
F1 F F2

Corpo in acciaio / Steel body


151 4.5 131.5 110 83 23.8 40 79 23 4.5 50.8 79.5 5.2 48.5 35 33.5 17.5 50.8 39.5 210 4 43 185 23.8 10.5 M10 OR 23.39x3.53
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 F3 F4 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken from
della valvola prelevato the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero da V2 the load with spool in neutral
verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa a valvola pressure is applied,
pilotata e protezione contro relief function against
sovrappressioni nel cilindro. overpressure in the cylinder.
Lattacco T deve essere collegato T port must be connected
direttamente a scarico. directly to the tank.
Lattacco E da collegare Port E has to be connected
alla valvola sullaltro cilindroidi to the valve of the second
sollevamento, pu servire boom cylinder, can be used
come emergenza manuale as manual lowering emergency.
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 4.9 bar/turn V2, C2 3/4"SAE6000
A068255.01.00 250 l/min 500 bar 8 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.04

Valvola in linea per escavatori serie 275D


Valve for earth moving machines "275D series"

LOAD L1 L
L2
L3
C2

H1
E L4 D1 (n.8)
E
B
T V2

=
Pil A Pil

H6
T

H
T
E

=
V2 V2 H2

H5
Pil

H7
H3

H4
= =

C2 O-RING
L5
L6
B
p (bar)

CURVE CARATTERISTICHE D (n.4) HEX32


= = Pil T V2

S1
PERFORMANCE CURVES
56 C2 E A
48
PRESSIONE / PRESSURE -

V2

=
40
=

32
C2

S3

S
24
=

16 C2

=
8 V2
E
0 70 140 210 280 350 F3 Pil T V2

S2
PORTATA / FLOW - Q (l/min) F2
F1 F

Corpo in acciaio / Steel body


177 4.5 157.5 135 100 23.8 47 89 23 4.5 50.8 89.5 5.5 57.5 38 38.5 20 50.8 49.5 250 4 221.5 23.8 10.5 M10 OR 23.39x3.53
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 F3 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato dai from the machine manipulators,
manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero the load with spool in neutral
da V2 verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot pressure
controllo della discesa a valvola is applied, relief function
pilotata e protezione contro against overpressure
sovrappressioni nel cilindro. in the cylinder. T port must be
Lattacco T deve essere collegato connected directly to the tank.
direttamente a scarico. Port E has to be connected
Lattacco E da collegare to the valve of the
alla valvola sullaltro cilindroidi second boom cylinder,
sollevamento, pu servire can be used as manual
come emergenza manuale lowering emergency.
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 3.4 bar/turn V2, C2 3/4"SAE6000
A068255.02.00 350 l/min 500 bar 12 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.05

Valvola in linea per escavatori serie EMM 210D


Valve for earth moving machines "EMM 210D series"

L1 L
LOAD
L2
L3
C2 D1 (n.8)

H1
E L4
E
B
T
Pil A Pil
V2

M10
=
T T

H6

H
V2 V2 E

=
H2

H7
H3
Pil

H4
C2

H5
= =
L6
O-RING L7
D (n.4) B
p (bar)

CURVE CARATTERISTICHE F4 HEX24


Pil T V2

S1
PERFORMANCE CURVES = =
70
C2 E A
PRESSIONE / PRESSURE -

60
V2

=
50
=

40
C2

S3

S
30
=

20
C2
V2

=
10

0 25 50 75 100 125150 175 200 225 250


E
PORTATA / FLOW - Q (l/min)
Pil T V2
F3

S2
F1 F F2

Corpo in acciaio / Steel body


151 4.5 131.5 110 83 22.2 40 79 23 4.5 47.6 79.5 5.2 48.5 35 33.5 17.5 47.6 40 210 4 43 185 22.2 10.5 M10 OR 23.39x3.53
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 F3 F4 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero da V2 the load with spool in neutral
verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa a valvola pressure is applied,
pilotata e protezione contro relief function against
sovrappressioni nel cilindro. overpressure in the cylinder.
Lattacco T deve essere collegato T port must be connected
direttamente a scarico. directly to the tank.
Lattacco E da collegare Port E has to be connected
alla valvola sullaltro cilindroidi to the valve of the second
sollevamento, pu servire boom cylinder, can be used
come emergenza manuale as manual lowering emergency.
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure RangeStandard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 4.9 bar/turn V2, C2 3/4"SAE3000
A068355.01.00 250 l/min 500 bar 8 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.06

Valvola in linea per escavatori serie EMM 275D


Valve for earth moving machines "EMM 275D series"

L1 L
LOAD
L2
L3
C2 D1 (n.8)

H1
E L4
E
B
T V2

=
Pil A Pil

H6

H
T T
E

=
V2 V2 H2
Pil

H5

H7
H3

H4
= =
HEX32

C2 L5
O-RING L6
p (bar)

D (n.4) B
Pil T V2

S1
CURVE CARATTERISTICHE = = A
PERFORMANCE CURVES
60 C2 E
PRESSIONE / PRESSURE -

40

=
V2
=

30
20 C2
S3

S
C2
10 V2
=

=
0
80 160 240 320 400
E
PORTATA / FLOW - Q (l/min) F2 Pil T V2
F1

S2
F

Corpo in acciaio / Steel body


177 4.5 157.5 135 100 27.8 47 89 23 4.5 57.2 89.5 5.5 57.5 38 38.5 20 57.2 49.5 250 221.5 27.8 12.5 M12 OR 32.9x3.53
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold
permette: il usso libero the load with spool in neutral
da V2 verso C2, il sostentamento position or with the pump
del carico con distributore not running, controlled
in neutro o pompa ferma, movement when pilot
controllo della discesa a valvola pressure is applied,
pilotata e protezione contro relief function against
sovrappressioni nel cilindro. overpressure in the cylinder.
Lattacco T deve essere collegato T port must be connected
direttamente a scarico. directly to the tank.
Lattacco E da collegare Port E has to be connected
alla valvola sullaltro cilindroidi to the valve of the second
sollevamento, pu servire boom cylinder, can be used
come emergenza manuale as manual lowering emergency.
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 3.4 bar/turn V2, C2 1"SAE6000
A068455.01.00 400 l/min 500 bar 12 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.07

Valvola in linea per escavatori serie EMM 275D


Valve for earth moving machines "EMM 275D series"

L1 L
LOAD L2
L3
L4 D1 (n.8)
C2

H1
E = =
E
B
T
V2

=
Pil A Pil

H
T

H6
T
V2 V2 Pil E
H2

H5

H7
H3

H4
HEX32

C2 L5
O-RING L6

D (n.4) B
p (bar)

CURVE CARATTERISTICHE V2

S1
= = Pil T
PERFORMANCE CURVES
E A
45
PRESSIONE / PRESSURE -

=
V2

30 C2
=
S3
C2

S
15
C2
V2
=

=
0 100 200 300 400 500 E
PORTATA / FLOW - Q (l/min) F3 Pil T V2
F2

S2
F1 F

Corpo in acciaio / Steel body


177 4.5 157.5 135 100 31.8 45 99 23 4.5 66.7 99.5 5.2 67.5 45.5 45.5 23 66.7 49.5 260 5.5 227 31.8 14.5 M14 OR 4143 36.09x3.53
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 H7 F F1 F2 F3 D D1 O-RING

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio della The pilot signal is taken
valvola prelevato dai from the machine manipulators,
manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero with spool in neutral position
da V2 verso C2, il sostentamento or with the pump not running,
del carico con distributore in controlled movement
neutro o pompa ferma, controllo when pilot pressure
della discesa a valvola is applied, relief function
pilotata e protezione contro against overpressure
sovrappressioni nel cilindro. in the cylinder. T port
Lattacco T deve essere collegato must be connected directly
direttamente a scarico. to the tank. Port E
Lattacco E da collegare has to be connected to the valve
alla valvola sullaltro cilindroidi of the second boom cylinder,
sollevamento, pu servire can be used as manual
come emergenza manuale lowering emergency.
per abbassare il carico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 3-15 bar 7.5 bar 3.4 bar/turn V2, C2 1 1/4"SAE6000
A068555.01.00 500 l/min 500 bar 15 kg
B 200-400 bar 350 bar 215 bar/turn E, Pil, T 1/4"G
Pag. 06.15.20

Valvola di blocco e controllo discesa


Load holding-metering valve for cranes

2 S2 S S1
LOAD S3 D S4

L1
3
C2 C2

T 1
E 2 1

S5
4
P
3

L
S6

S7
V2 BL
4
T
H2 H3
L2

H1
H
p (bar)

CURVE CARATTERISTICHE
F5 D2 (n4)
PERFORMANCE CURVES F6
F7
40
F4 = =
PRESSIONE / PRESSURE -

F3
F4
30 C2
E
F2

V2
F1

20

F8
F

C2 V2
10 BL
C2
V2 C2

F9
0 F10
40 80 120 160 200
G

D1 (n4)
PORTATA / FLOW - Q (l/min)
G1
Corpo in acciaio / Steel body
129 10.6 16 156 74 4.5 23.8 47 94 60.5 50.8 176 148 43 23 68 50.5 34 29.5 21 57 24.5 50.8 67 23.8 58.5 19.5 50 19 10.5 M10
L L1 L2 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 F F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 G G1 D D1 D2

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio della The pilot signal is taken from
valvola prelevato dai manipolatori the machine manipulators,
di comando distributore e la valvola the valve allows: free ow from
permette: il usso libero da V2 V2 to C2, to hold the load with
verso C2, il sostentamento del spool in neutral position or with
carico con distributore in neutro the pump not running, controlled
o pompa ferma, controllo della movement when pilot pressure
discesa a valvola pilotata e is applied, relief function against
protezione contro sovrappressioni overpressure in the cylinder.
nel cilindro. Lattacco T deve essere T port must be connected
collegato direttamente a scarico. directly to the tank.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916005 - 916013

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 6-18 bar 12 bar 5 bar/turn V2-C2 3/4"SAE6000
A068271.01.00 2 5-18 bar 8 bar 3,2 bar/turn 200 l/min 420 bar E-P 1/4"G 10.4 kg
3 100-350 bar 350 bar 110 bar/turn T 1/2"G
Pag. 06.15.21

Valvola di blocco e controllo discesa


Load holding-metering valve for cranes

2 S2 S S1
S3 D S4

L1
LOAD
3
C2 C2
1
T

S5
2 1
E
3

L
4
0.7 P S6

S7
4
0.5 V2 BL T
L2 H2 H3
H1
H

CURVE CARATTERISTICHE F5 D2 (n4)


p (bar)

PERFORMANCE CURVES F6
F7
40 F4 = =

F3
F4
C2
PRESSIONE / PRESSURE -

30 E
F2
F1

V2

F8
F

20
V2
C2 BL
10 C2 C2
V2

F9
0 F10
40 80 120 160 200
G

D1 (n4)
PORTATA / FLOW - Q (l/min)
G1

Corpo in acciaio / Steel body


129 10.6 16 156 74 4.5 23.8 47 94 60.5 50.8 176 148 43 23 68 50.5 34 29.5 21 57 24.5 50.8 67 23.8 58.5 19.5 50 19 10.5 M10
L L1 L2 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 F F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 G G1 D D1 D2

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio The pilot signal is taken
della valvola prelevato from the machine manipulators,
dai manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero with spool in neutral position
da V2 verso C2, il sostentamento or with the pump not running,
del carico con distributore controlled movement
in neutro o pompa ferma, when pilot pressure is applied,
controllo della discesa relief function against
a valvola pilotata e protezione overpressure in the cylinder.
contro sovrappressioni T port must be connected
CODICE ORDINAZIONE SEALING ORDERING nel cilindro. Lattacco T directly to the tank.
PIOMBATURA CODE deve essere collegato
916005 - 916013 direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 6-18 bar 12 bar 5 bar/turn V2-C2 3/4"SAE6000
A068271.02.00 2 5-18 bar 8 bar 3,2 bar/turn 200 l/min 420 bar E-P 1/4"G 10.4 kg
3 100-350 bar 350 bar 110 bar/turn T 1/2"G
Pag. 06.15.22

Valvola di blocco e controllo discesa


Load holding-metering valve for cranes

LOAD
2
L4 L5
3
C2 C2 D

H1
1
T 2

F1

D1 (n.4)
H3
E 1

H
3
P

G2
F
T HEX5
H2
V2 T
L3
L2 HEX17
L1 L

D2 (n.4)
p (bar)

CURVE CARATTERISTICHE
F
PERFORMANCE CURVES L6
HEX32
= =

S3
40

F1
PRESSIONE / PRESSURE -

30 P E V2
S2

V2

= =

S1
S

20
C2
10 C2
C2
V2 F2
0 50 100 150 200 250 D1 (n.4)
G

PORTATA / FLOW - Q (l/min)


G1

Corpo in acciaio / Steel body

189 4.5 124.5 37 64.5 56.5 16 58 57 29 16 129 25 12 94 50.8 23.8 50.5 19.5 50 70 19 10.5 M10
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 F F1 F2 G G1 G2 D D1 D2

DESCRIZIONE DESCRIPTION

Collegare allimpianto come To be connected as shown.


da schema. Il pilotaggio della The pilot signal is taken from
valvola prelevato dai the machine manipulators,
manipolatori di comando the valve allows: free ow
distributore e la valvola from V2 to C2, to hold the load
permette: il usso libero da V2 with spool in neutral position
verso C2, il sostentamento or with the pump not running,
del carico con distributore controlled movement when
in neutro o pompa ferma, pilot pressure is applied, relief
controllo della discesa a valvola function against overpressure
pilotata e protezione contro in the cylinder. T port must be
sovrappressioni nel cilindro. connected directly to the tank.
Lattacco T deve essere collegato
direttamente a scarico.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 6-14 bar 9 bar 5 bar/turn V2-C2 3/4"SAE6000
A068271.03.00 2 15-30 bar 20 bar 3,2 bar/turn 250 l/min 420 bar E-P 1/4"G 10.7 kg
3 100-350 bar 350 bar 110 bar/turn T 1/2"G
Pag. 06.16.01

Valvola di bilanciamento semplice eetto, serie 165


Single overcenter "165 series"

C2

HEX21

Pil

50,5
HEX32

V2

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - Dp (bar)

30 V2 1 1/16-12 UNF-2A
25

65,4
20
C2
V2

15
C2
10 V2
C2

5
Pil
0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min) CODICE SEDE CAVITY CODE


HBS.96.S.03A (Pag. 99.08.01)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V2 to C1, to hold the load
usso libero da V2 verso C1, with spool in neutral position
sostentamento del carico con or with the pump not running,
distributore in neutro o a pompa controlled movement when
ferma, controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

120 Nm

Rapporto di Campo di Taratura Incremento Portata Pressione


Codice Ordinazione Peso
Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C069601.01.00 4.25:1 100-350 bar 350 bar 135 bar/turn 60 l/min 400 bar 0.28 kg
Pag. 06.16.02

Valvola di bilanciamento semplice eetto, serie 190


Single overcenter "190 series"

C2 HEX24

HEX32
Pil

51
V2

CURVE CARATTERISTICHE
PERFORMANCE CURVES V2 1 3/16-12 UNF-2A
PRESSIONE / PRESSURE - Dp (bar)

50

81
40

30 C2
V2
20
C2
10 C2 Pil
V2
0
15 30 45 60 75 90
CODICE SEDE CAVITY CODE
PORTATA / FLOW - Q (l/min)
HBS.90.U.03A (Pag. 99.02.01)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole a open centre spools.
centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V2 to C1, to hold the load
usso libero da V2 verso C1, with spool in neutral position
sostentamento del carico con or with the pump not running,
distributore in neutro o a pompa controlled movement when
ferma, controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

150 Nm

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C069501.01.00 4.25:1 100-350 bar 350 bar 135 bar/turn 90 l/min 350 bar 0.4 kg
Pag. 06.16.03

Valvola di bilanciamento semplice eetto, serie 210


Single overcenter "210 series"

C2

HEX27

Pil

66,6
HEX38

V2

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - Dp (bar)

25
M33x2
20 V2

15 V2

10 C2
C2

95
5 V2 C2
0
40 80 120 160
PORTATA / FLOW - Q (l/min)

Pil
CODICE SEDE CAVITY CODE
HBS.46.S.03B (Pag. 99.05.02)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata per suggested for use with
distributori con spole a centro open centre spools.
aperto in neutro. Collegare To be connected as shown.
allimpianto come da schema. The valve allows: free ow
La valvola permette: usso libero from V2 to C1, to hold the load
da V2 verso C1, sostentamento with spool in neutral position
del carico con distributore in or with the pump not running,
neutro o a pompa ferma, controlled movement when
controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

220 Nm

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C064601.01.00 4:1 100-350 bar 350 bar 110 bar/turn 150 l/min 350 bar 0.7 kg
Pag. 06.16.04

Valvola di bilanciamento semplice eetto, serie SM


Single overcentre "SM series"

C2

61 max
Pil
HEX25

45,7
V2

17
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25
20
19,05
15 Pil
V2
46,5
10
C2
5 C2 V2
V2
0 15 30 45 60
PORTATA / FLOW - Q (l/min)
C2 17,47
CODICE SEDE CAVITY CODE 7/8-14 UNF-2A
HBS.38.S.02A (Pag. 99.08.02)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neutro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V2 to C2, to hold
usso libero da V2 verso C2, the load with spool in neutral
sostentamento del carico position or with the pump
con distributore in neutro not running, controlled
o a pompa ferma, controllo movement when pilot pressure
del movimento di discesa is applied, relief function
del carico a seguito against overpressure
del pilotaggio della valvola in the cylinder.
pilotaggio, protezione
da sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

41-47 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C069401.01.00 4:1 100-350 bar 350 bar 106 bar/turn 60 l/min 350 bar 0.2 kg
C069401.02.00 8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 350 bar 0.2 kg
Pag. 06.16.05

Valvola di bilanciamento semplice eetto, serie SM


Single overcentre "SM series"

HEX4
C2

HEX13

Pil

HEX28

64
V2

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

25
20
15
C2 23,8
10 Pil
V2 V2

57,7
5 C2
0 20 40 60 80 100 120
V2
22,22
PORTATA / FLOW - Q (l/min)

C2
CODICE SEDE CAVITY CODE 1-1/16-12UN-2A

HBS.96.U.03A (Pag. 99.02.01)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools.
a centro aperto in neautro. To be connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V2 to C2, to hold the load
usso libero da V2 verso C2, with spool in neutral position
sostentamento del carico con or with the pump not running,
distributore in neutro o a pompa controlled movement when
ferma, controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

81-95 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C060801.01.00 4:1 60-210 bar 180 bar 42 bar/turn 120 l/min 350 bar 0.4 kg
C060801.03.00 4:1 180-350 bar 200 bar 88 bar/turn 120 l/min 350 bar 0.4 kg
Pag. 06.16.06

Valvola di bilanciamento semplice eetto, serie SM


Single overcentre "SM series"

C2

Pil HEX32

69,1
46
V2

32
122,8
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

25
20
15 Pil

53,7
C2
10
V2 V2
5 C2
0 V2
20 40 60 80 100

PORTATA / FLOW - Q (l/min)

C2
23
CODICE SEDE CAVITY CODE 24,5
HBS.42.M.03A (Pag. 99.05.01)
M27x1.5

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole open centre spools. To be
a centro aperto in neutro. connected as shown.
Collegare allimpianto come The valve allows: free ow
da schema. La valvola permette: from V2 to C2, to hold
usso libero da V2 verso C2, the load with spool in neutral
sostentamento del carico position or with the pump
con distributore in neutro not running, controlled
o a pompa ferma, controllo movement when
del movimento di discesa pilot pressure is applied,
del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione
da sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

85-100 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C065901.01.00 4:1 150-350 bar 350 bar 88 bar/turn 100 l/min 350 bar 0.4 kg
Pag. 06.16.07

Valvola di bilanciamento semplice eetto, serie SM


Single overcentre "SM series"

37,5
C2

HEX19
Pil

92.5max
V2 HEX38

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - Dp (bar)

PERFORMANCE CURVES
20
16
M33x2
12
V2
8
C2 C2
4 V2 C2

66
0 20 40 60 80 100 120 140
V2
PORTATA / FLOW - Q (l/min)

CODICE SEDE CAVITY CODE Pil


27
HBS.46.M.03A (Pag. 99.05.02)
28

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Single overcenter valve,


semplice eetto, consigliata suggested for use with
per distributori con spole a centro open centre spools.
aperto in neautro. Collegare To be connected as shown.
allimpianto come da schema. The valve allows: free ow
La valvola permette: usso libero from V2 to C2, to hold
da V2 verso C2, sostentamento the load with spool
del carico con distributore in neutral position or with
in neutro o a pompa ferma, the pump not running,
controllo del movimento di controlled movement when
discesa del carico a seguito pilot pressure is applied,
del pilotaggio della valvola relief function against
pilotaggio, protezione overpressure in the cylinder.
da sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

65-70 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C064601.02.00 6.9:1 90-250 bar 250 bar 102 bar/turn 140 l/min 350 bar 0.7 kg
Pag. 06.16.08

Valvola di bilanciamento semplice eetto


Single overcentre

C2
HEX19

Pil
HEX34

131.5 max
V2

HEX38

103
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - Dp (bar)

PERFORMANCE CURVES

20
16

16
12
8 V2
C2 C2
4 V2 C2

66
0 20 40 60 80 100 120 140 V2
PORTATA / FLOW - Q (l/min)

Pil
M33x2
CODICE SEDE CAVITY CODE
37,5
HBS.46.M.03A (Pag. 99.05.02)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole a centro centre spools. To be connected
chiuso. Collegare allimpianto as shown. The valve allows:
come da schema. La valvola free ow from V2 to C2,
permette: usso libero da V2 to hold the load with spool
verso C2, sostentamento in neutral position or with
del carico con distributore the pump not running,
in neutro o a pompa ferma, controlled movement when
controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

65-70 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C064603.01.00 4.7:1 90-250 bar 250 bar 85 bar/turn 140 l/min 350 bar 1 kg
Pag. 06.16.09

Valvola di bilanciamento semplice eetto


Single overcentre

C2 Hex13

Hex21
Pil

59,2
V2
Hex24

CURVE CARATTERISTICHE

4
PRESSIONE / PRESSURE - Dp (bar)

PERFORMANCE CURVES

10

12
8
C1 1/2"G

25
6 Pil
C2
51,5
4 C2

42
2 C1
V2
0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min)

C2
CODICE SEDE CAVITY CODE 16

HBS.04.G.03A (Pag. 99.07.00) 18

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with open
per distributori con spole centre spools. To be connected
a centro aperto in neutro. as shown. The valve allows:
Collegare allimpianto come free ow from V2 to C2,
da schema. La valvola permette: to hold the load with spool
usso libero da V2 verso C2, in neutral position or with
sostentamento del carico con the pump not running,
distributore in neutro o a pompa controlled movement when
ferma, controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

30-35 Nm

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C060401.02.00 4.5:1 100-350 bar 350 bar 65 bar/turn 30 l/min 350 bar 0.2 kg
Pag. 06.16.10

Valvola di bilanciamento semplice eetto, serie 275


Single overcenter "275 series"

C2

Pil

89
V2
Hex45
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
36
30
24 M42x2
V2

18 V2
12
C2

C2 38
6 V2

115,5
88
0
60 120 180 240 300 C2
36
PORTATA / FLOW - Q (l/min)
27

CODICE SEDE CAVITY CODE


Pil
HBS.52.M.03A (Pag. 99.05.03)

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento Single overcenter valve,


a semplice eetto, consigliata suggested for use with
per distributori con spole a centro open centre spools.
aperto in neutro. Collegare To be connected as shown.
allimpianto come da schema. The valve allows: free ow
La valvola permette: usso libero from V2 to C2, to hold the load
da V2 verso C2, sostentamento with spool in neutral position
del carico con distributore or with the pump not running,
in neutro o a pompa ferma, controlled movement when
controllo del movimento pilot pressure is applied,
di discesa del carico a seguito relief function against
del pilotaggio della valvola overpressure in the cylinder.
pilotaggio, protezione da
sovrapressioni nel cilindro.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

246-272 N*m

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Pressure Weight
Range Setting Increase
C065201.01.00 4:1 180-350 bar 350 bar 70 bar/turn 300 l/min 350 bar 1.5 kg
Pag. 07.01.01

Valvola di blocco bilanciata doppia in linea serie 140


Dual overcenter valve in line "140 series"

HEX4
L6 L5
HEX13

C2 C1 C2 C1

H1
H
=
V2 V1
V2 V1

H2
L4 L3
L2

L1 L L1
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25
20 V1 D (n.2)
15 C1
10
C1
=

5 V1
S
=

0 5 10 15 20 25 30
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A070261.22.00 138 ~42 69 92 23 38 50 25 45 28 8.5 6.5
COD. L L1 L2 L3 L4 L5 L6 S H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the control in
controllo nel verso opposto the opposite direction.
tramite lazione della The load is locked when the spool
pressione di pilotaggio. valve is in neutral position or the
Assicura il blocco del carico con pump is not running (max leakage
distributore in neutro o a pompa 5 drops/min).
ferma (tralamento max. 5 Peaks of pressure can be relieved
gocce/min) e permette di scaricare only with open centre spool valves.
i picchi di pressione se la spola del The valve must be set at 1,3 times
distributore a centro aperto. the max. load induced pressure.
Tarare ad almeno 1,3 volte la Back pressure downstream the
pressione massima indotta dal valve increases the setting and the
carico. Eventuali contropressioni requested pilot pressure.
sullo scarico aumentano la
pressione di taratura e di pilotaggio
richiesta per pilotare la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070261.22.00 4.1:1 100-350 Bar 300 Bar 180 Bar/turn 30 L/min 500 Bar 1/4"g 1.2 Kg
Pag. 07.01.03

Valvola di blocco bilanciata doppia in linea serie 165


Dual overcenter valve in line "165 series"

L1 L L1
= =
C1 C2
L2 L3

H1
Y Y
C1 C2

=
A B

H2
H
=
p (bar)

CURVE CARATTERISTICHE A B
HEX13 Y Y
PERFORMANCE CURVES
L5 L4
25 HEX4
PRESSIONE / PRESSURE -

20
15 A C1 D (n.2)
10 C1 A

5
=
L6

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 ~42 51.5 48 112 19.5 35 65 11 43 8.5 1/2"G
151 ~42 51.5 48 112 19.5 30 55 8.5 38 8.5 3/8"G
L L1 L2 L3 L4 L5 L6 H H1 H2 D Y

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola relieved only with open centre
del distributore a centro spool valves. The valve
aperto. Tarare ad almeno must be set at 1,3 times
1,3 volte la pressione massima the max. load induced
indotta dal carico. Eventuali pressure. Back pressure
contropressioni sullo scarico downstream the valve
CODICE ORDINAZIONE SEALING ORDERING aumentano la pressione increases the setting
PIOMBATURA CODE di taratura e di pilotaggio and the requested
916003 richiesta per pilotare la valvola. pilot pressure.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070361.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070361.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070361.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070461.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
A070461.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
A070461.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
Pag. 07.01.03B

Valvola di blocco bilanciata doppia in linea serie 165


Dual overcenter valve in line "165 series"

L1 L L1
L3 L2
C1 C2
L5 L4
C1 C2

H1
A B

=
H
p (bar)

CURVE CARATTERISTICHE

=
PERFORMANCE CURVES
25 HEX13 A B
PRESSIONE / PRESSURE -

20 L7 L6
A C1 HEX4
15
C1 A D (n.2)
10
5
=

0 10 20 30 40 50 60
S

PORTATA / FLOW - Q (l/min)


=

Corpo in alluminio / Aluminium Body


151 ~42 48 51 130 10.5 112 19.5 35 65 10 6.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load
di pilotaggio. Assicura il blocco is locked when the spool
del carico con distributore valve is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure
di pressione se la spola del can be relieved only
distributore a centro aperto. with open centre spool
Tarare ad almeno 1,3 volte valves. The valve must
la pressione massima indotta be set at 1,3 times the max.
dal carico. Eventuali load induced pressure.
contropressioni sullo scarico Back pressure downstream
aumentano la pressione the valve increases
di taratura e di pilotaggio the setting and the requested
richiesta per pilotare la valvola. pilot pressure.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B070461.04.00 2.7:1 80-350 bar 300 bar 85 bar/turn 60 l/min 500 bar 1/2"G 1.1 kg
B070461.05.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 1.1 kg
B070461.06.00 8.8:1 100-350 bar 350 bar 90 bar/turn 60 l/min 500 bar 1/2"G 1.1 kg
Pag. 07.01.04

Valvola di blocco bilanciata doppia in linea serie BR


Dual overcenter valve in line "BR series"

L1 L L1
L3 L2 L3
L5 L4 L5

H2
C1 C2
C1 C2

H1
H
A B
PRESSIONE / PRESSURE - p (bar)

A B
HEX13 L6 L7
CURVE CARATTERISTICHE
PERFORMANCE CURVES
10 HEX4
8 D (n.2)
6
4 B
=

C2
2 C2
S
=

B
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

*Corpo in alluminio / Aluminium body

124 ~50 104 10 69 27.5 45 34 30 60 34 14 6.5


L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da A>C1 o B>C2 e il A>C1 or B>C2 and the control in
controllo nel verso opposto the opposite direction.
tramite lazione della pressione The load is locked when the
di pilotaggio. Assicura il blocco spool valve is in neutral position
del carico con distributore in or the pump is not running (max
neutro o a pompa ferma leakage 5 drops/min).
(tralamento max. 5 gocce/min) Peaks of pressure can be
e permette di scaricare i picchi di relieved only with open centre
pressione se la spola del spool valves. The valve must be
distributore a centro aperto. set at 1,3 times the max. load
Tarare ad almeno 1,3 volte la induced pressure.
pressione massima indotta dal Back pressure downstream the
carico. Eventuali contropressioni valve increases the setting and
sullo scarico aumentano la the requested pilot pressure.
CODICE ORDINAZIONE SEALING ORDERING pressione di taratura e di
PIOMBATURA CODE pilotaggio richiesta
916003 per pilotare la valvola.

Codice Ordinazione Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso
Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070300.11.00 4.84:1 100-350 Bar 350 Bar 125 Bar/turn 45 L/min 500 Bar 3/8"g 1.6 Kg
A070300.12.00 6.83:1 100-450 Bar 300 Bar 175 Bar/turn 45 L/min 500 Bar 3/8"g 1.6 Kg
* B070300.11.00 4.84:1 100-350 Bar 350 Bar 125 Bar/turn 45 L/min 350 Bar 3/8"g 0.8 Kg
* B070300.12.00 6.83:1 100-400 Bar 300 Bar 175 Bar/turn 45 L/min 350 Bar 3/8"g 0.8 Kg
Pag. 07.01.05

Valvola di blocco bilanciata doppia in linea serie BR


Dual overcenter valve in line "BR series"

L1 L L1
L3 L2 L3

C1 C2 L5 L4 L5

H3
C1 C2

H1
A B

H2
H
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES A B
14 HEX13 L6 L7
12
10 HEX4 D (n.2)
8
6 B
4
C2 C2
=

2
B
S

0 10 20 30 40 50 60 80
=

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


140 ~51 125 7.5 80 30 52 36 35 70 38 54 8 8.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da A>C1 o B>C2 e il A>C1 or B >C2 and the control in
controllo nel verso opposto the opposite direction.
tramite lazione della pressione The load is locked when the
di pilotaggio. Assicura il blocco spool valve is in neutral position
del carico con distributore or the pump is not running (max
in neutro o a pompa ferma leakage 5 drops/min ). Peaks of
(tralamento max. 5 gocce/min) pressure can be relieved only
e permette di scaricare i picchi di with open centre spool valves.
pressione se la spola del The valve must be set at 1,3
distributore a centro aperto. times the max. load induced
Tarare ad almeno 1,3 volte la pressure. Back pressure
pressione massima indotta dal downstream the valve increases
carico. Eventuali contropressioni the setting and the requested
sullo scarico aumentano la pilot pressure.
pressione di taratura e di
pilotaggio richiesta
per pilotare la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070400.11.00 4.84:1 100-350 Bar 300 Bar 125 Bar/turn 80 L/min 500 Bar 1/2"g 2.2 Kg
A070400.12.00 6.83:1 100-450 Bar 300 Bar 175 Bar/turn 80 L/min 500 Bar 1/2"g 2.2 Kg
Pag. 07.01.05A

Valvola di blocco bilanciata doppia in linea serie BR angiabile


Flangeable dual overcenter valve in line "BR series"

L1 L L1

L3 L2

C1 C2

V1 V2 C1 C2

H2
H1
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES HEX13 V1 V2
14

H3
L5 L4
12 HEX4
10 L7 L6
8
6
4 V2 O-RING D (n.4)
2 C2 C2
V2
0 10 20 30 40 50 60 80
S

PORTATA / FLOW - Q (l/min)


S1

Corpo in alluminio / Aluminium body


140 ~49 125 7.5 52 36 33.5 73 34 8 70 31.5 54 7.5 OR 119 15.08x2.62
L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 H2 H3 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the control
controllo nel verso opposto in the opposite direction. The
tramite lazione della pressione load is locked when the spool
di pilotaggio. Assicura il blocco valve is in neutral position or
del carico con distributore in the pump is not running (max
neutro o a pompa ferma leakage 5 drops/min). Peaks of
(tralamento max. 5 gocce/min) pressure can be relieved only
e permette di scaricare i picchi di with open centre spool valves.
pressione se la spola del The valve must be set at 1,3
distributore a centro aperto. times the max. load induced
Tarare ad almeno 1,3 volte la pressure. Back pressure
pressione massima indotta dal downstream the valve increases
carico. Eventuali contropressioni the setting and the requested
sullo scarico aumentano la pilot pressure.
pressione di taratura e di
pilotaggio richiesta per pilotare
la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B070416.01.00 4.84:1 100-350 Bar 300 Bar 125 Bar/turn 80 L/min 350 Bar 1/2"g 1.1 Kg
B070416.02.00 6.83:1 100-350 Bar 300 Bar 175 Bar/turn 80 L/min 350 Bar 1/2"g 1.1 Kg
B070416.03.00 9.5:1 100-350 Bar 300 Bar 68 Bar/turn 80 L/min 350 Bar 1/2"g 1.1 Kg
Pag. 07.01.05B

Valvola di blocco bilanciata doppia in linea angiabile serie BR


Flangeable dual overcenter valve in line "BR series"

L1 L L1
L3 L2 L3
L5 L4 L5
C1 C2 L7 L6

H2

H1
A B
C1 C2

H
H3
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
HEX13 A B
PERFORMANCE CURVES L8 L9 O-RING
10
HEX4
8 L10 L11

6 D (n.4)
4 B
C2
S1

2 C2
S

B
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)
Corpo in alluminio / Aluminium body
124 ~50 104 10 69 27.5 62 31 29.5 65 45 34 30 15 60 34 14 38 6.5 OR 3043 10.78x2.62
L L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 S S1 H H1 H2 H3 D O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da A>C1 o B>C2 e il A>C1 or B>C2 and the control in
controllo nel verso opposto the opposite direction. The load
tramite lazione della pressione is locked when the spool valve is
di pilotaggio. Assicura il in neutral position or the pump
blocco del carico con distributore is not running (max leakage 5
in neutro o a pompa ferma drops/min). Peaks of pressure
(tralamento max. 5 gocce/min) can be relieved only with open
e permette di scaricare i picchi di centre spool valves. The valve
pressione se la spola del must be set at 1,3 times the
distributore a centro aperto. max. load induced pressure.
Tarare ad almeno 1,3 volte la Back pressure downstream the
pressione massima indotta dal valve increases the setting and
carico. Eventuali contropressioni the requested pilot pressure.
sullo scarico aumentano la
pressione di taratura e di
pilotaggio richiesta
per pilotare la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070316.01.00 4.84:1 50-350 Bar 350 Bar 125 Bar/turn 45 L/min 350 Bar 3/8"g 0.8 Kg
A070316.02.00 6.83:1 50-450 Bar 350 Bar 175 Bar/turn 45 L/min 350 Bar 3/8"g 0.8 Kg
Pag. 07.01.05C

Valvola di blocco bilanciata doppia in linea angiabile serie BE


Flangeable dual overcenter valve in line "BE series"

C2 C1 L1 L L1
L3 L2 L2

H1

H3
C1 V1 V2 C2

H
H2
V2 V1
HEX24
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE L5 L4 L4 L5
PERFORMANCE CURVES
25
20 D (n.6)
15
V2
10
C2
=

5 C2
S

V2
=

0 8 16 24 32 40
PORTATA / FLOW - Q (l/min)
O-RING

Corpo in alluminio / Aluminium body


145 61.5 63.5 9 24.5 25.5 34 65 17.5 40 38.5 8.5 OR 3062 15.54x2.62
L L1 L2 L3 L4 L5 S H H1 H2 H3 D O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the control
controllo nel verso opposto in the opposite direction. The
tramite lazione della pressione load is locked when the spool
di pilotaggio. Assicura il blocco valve is in neutral position or
del carico con distributore the pump is not running (max
in neutro o a pompa ferma leakage 5 drops/min). Peaks of
(tralamento max. 5 gocce/min) pressure can be relieved
e permette di scaricare i picchi di only with open centre spool
pressione se la spola del valves. The valve must be set at
distributore a centro aperto. 1,3 times the max. load induced
Tarare ad almeno 1,3 volte la pressure. Back pressure
pressione massima indotta dal downstream thevalve increases
carico. Eventuali contropressioni the setting and the requested
sullo scarico aumentano la pilot pressure.
pressione di taratura e di
pilotaggio richiesta per pilotare
la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B076016.01.00 3.6:1 100-350 Bar 350 Bar 105 Bar/turn 40 L/min 350 Bar Flangeable 8 1.4 Kg
Pag. 07.01.05D

Valvola di blocco bilanciata doppia angiabile serie 190


Flangeable dual overcenter valve "190 series"

L1 L L1

M1 C2 C1 M1 L3 L2

H2
=
V2 V1

H1
H
V2 V1

=
CURVE CARATTERISTICHE HEX4 L5 L4
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

40 HEX13 L7 L6
35
30 D (n.4)
25
20
V2
=

15
S

10 C2
=

5 C2
V2
0 15 30 45 60 75 90 O-RING
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A070481.61.00 185 ~34.9 131 27 54 65.5 92 46.5 34.5 65 38 13.5 8.5 OR 3056 13.95x2.62
COD. L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure
di pressione se la spola del can be relieved only with
distributore a centro aperto. open centre spool valves.
Tarare ad almeno 1,3 volte The valve must be set
la pressione massima indotta at 1,3 times the max. load
dal carico. Eventuali induced pressure.
contropressioni sullo scarico Back pressure downstream
aumentano la pressione the valve increases
di taratura e di pilotaggio the setting and the
richiesta per pilotare la valvola. requested pilot pressure.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070481.61.00 4.25:1 100-350 bar 350 bar 135 bar/turn 90 l/min 500 bar 1/2"G 2.9 kg
Pag. 07.01.07A

Valvola di blocco bilanciata doppia in linea serie BR


Dual overcenter valve in line "BR series"

L1 L L1

L3 L2
)
C1 C2 n.2
C1 C2 D(

H1
H
A B

H3
PRESSIONE / PRESSURE - p (bar)

A B

H2
HEX17 L4 L5
CURVE CARATTERISTICHE
PERFORMANCE CURVES HEX5
28 L7 L6
24
20
16
12
8 B
=

4 C2 B C2
S
=

0 20 40 60 80 100 120 140


PORTATA / FLOW - Q (l/min)

*Corpo in acciaio / Steel body


175 ~66 107 34 62.5 50 155 10 40 90 70 10 38 10.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da A>C1 o B>C2 e il A>C1 or B>C2 and the control in
controllo nel verso opposto the opposite direction. The load
tramite lazione della pressione is locked when the spool valve is
di pilotaggio. Assicura il blocco in neutral position or the pump
del carico con distributore is not running (max leakage 5
in neutro o a pompa ferma drops/min). Peaks of pressure
(tralamento max. 5 gocce/min) can be relieved only with open
e permette di scaricare i picchi di centre spool valves. The valve
pressione se la spola del must be set at 1,3 times the
distributore a centro aperto. max. load induced pressure.
Tarare ad almeno 1,3 volte la Back pressure downstream the
pressione massima indotta dal valve increases the setting and
carico. Eventuali contropressioni the requested pilot pressure.
sullo scarico aumentano la
CODICE ORDINAZIONE SEALING ORDERING pressione di taratura e di
PIOMBATURA CODE pilotaggio richiesta per pilotare
916005 la valvola.

Ordinazione Pilotaggio Taratura Standard Per Giro Massima Max Porte Peso

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
* A070600.11.00 4.4:1 100-350 Bar 300 Bar 90 Bar/turn 140 L/min 500 Bar 3/4"g 4.6 Kg
* A070600.12.00 8.2:1 100-400 Bar 350 Bar 90 Bar/turn 140 L/min 500 Bar 3/4"g 4.6 Kg
B070600.11.00 4.4:1 100-350 Bar 300 Bar 90 Bar/turn 140 L/min 350 Bar 3/4"g 4.6 Kg
B070600.12.00 8.2:1 100-400 Bar 350 Bar 90 Bar/turn 140 L/min 350 Bar 3/4"g 4.6 Kg
Pag. 07.01.07B

Valvola di blocco bilanciata doppio eetto serie BE


Dual overcenter valve "BE series"

D(n2)
C1 C2

=
S
=
L1 L L1
V1 V2
= =
L3 L2

C1 C2
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

H
H2
28

H1
24
PRESSIONE / PRESSURE -

20 V1 V2
H3

16 L4 L5 HEX27
12
8 V2
C2 V2 C2
4
0 20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B070600.01.00 180 70 122 29 62 56 40 89 35 50 9.5 10.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 V1>C1 or V2>C2 and the control
e il controllo nel verso opposto in the opposite direction.
tramite lazione della pressione The load is locked when
di pilotaggio. Assicura il blocco the spool valve is in neutral
del carico con distributore position or the pump is not
in neutro o a pompa ferma running (max leakage 5
(tralamento max. 5 gocce/min) drops/min). Peaks of pressure
e permette di scaricare i picchi can be relieved only with open
di pressione se la spola del centre spool valves.
distributore a centro aperto. The valve must be set at 1,3
Tarare ad almeno 1,3 volte times the max. load induced
la pressione massima indotta pressure. Back pressure
dal carico. Eventuali downstream the valve
contropressioni sullo scarico increases the setting and
aumentano la pressione the requested pilot pressure.
di taratura e di pilotaggio
richiesta per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B070600.01.00 3:1 70-350 bar 120 bar 73 bar/turn 120 l/min 350 bar 3/4"G 2.5 kg
Pag. 07.01.07C

Valvola di bilanciamento doppio eetto, serie 210


Dual overcenter valve "210 series"
L1 L L1

L2
C1 C2

L4

L3
1 2

L5 HEX24
L6

V1 V2 H1 H

H2
C2 C1
p (bar)

CURVE CARATTERISTICHE

=
PERFORMANCE CURVES

S
25
PRESSIONE / PRESSURE -

20
15 V1 = V2 V1
10 C1 S1 D(n 2)
C1
5 S2
V1 2
0 25 50 75 100 125 150 1 C2

PORTATA / FLOW - Q (l/min) C1

S3
Corpo in alluminio / Aluminium body
B070461.09.00 130 ~43 20 29 70 39 91 70 82 48 ~216 110 10 10 8.5
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow


da V1>C1 o V2>C2 e il controllo from V1>C1 or V2>C2 and the
nel verso opposto tramite lazione control in the opposite direction.
della pressione di pilotaggio. Assicura The load is locked when the spool
il blocco del carico con distributore valve is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. Leakage 5 drops/min).
e permette di scaricare un picco Peaks of pressure can be relieved
di pressione se la spola del only with open centre spool valves.
distributore a centro aperto. The valve must be set at 1.3 times
Tarare ad almeno 1,3 volte la the max. load induced pressure.
pressione massima indotta dal carico. Back pressure downstream
Eventuali contropressioni sullo the valve increases the setting
scarico aumentano la pressione and the requested pilot pressure.
di taratura e di pilotaggio richiesta The one-way restrictors
per pilotare la valvola. Sulla linea on the pilot lines allow to dump
CODICE ORDINAZIONE SEALING ORDERING di pilotaggio una strozzatura the valve piloting.
PIOMBATURA CODE
unidirezionale regolabile permette
916013 di smorzare il pilotaggio della valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
1 265 bar
B070461.09.00 4:1 100-370 bar 108 bar/turn 150 l/min 380 bar 1/2"G 2.2 kg
2 370 bar
Pag. 07.01.07D

Valvola di blocco bilanciata doppia in linea serie BR


Dual overcenter valve in line "BR series"

L1 L L1
C1 C2
= =

L3 L5

S3
S2
C1 C2

V1 V2

S
S1
S4

V1 V2

S2
CURVE CARATTERISTICHE L2 L4
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES HEX17


21
HEX5
18
15 D (n2)
V2

12
C2

=
6

H
3
C2
V2

=
0
20 40 60 80 100120140160 180200
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A070800.01.00 218 82 max. 76 30 66 158 100 80 10 12 35 60 10.5
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 S4 H D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da D1>U1 o D2>C2 frommD1>U1 or D2>U2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve is
del carico con distributore in neutral position or the pump
in neutro o a pompa ferma is not running (max leakage
(tralamento max. 5 gocce/min) 5 drops/min). Peaks of
e permette di scaricare i picchi pressure can be relieved only
di pressione se la spola del with open centre spool valves.
distributore a centro aperto. The valve must be set at 1,3
Tarare ad almeno 1,3 volte la times the max. load induced
pressione massima indotta pressure. Back pressure
dal carico. Eventuali downstream the valve increases
CODICE ORDINAZIONE SEALING ORDERING contropressioni sullo scarico the setting and the
PIOMBATURA CODE aumentano la pressione requested pilot pressure.
916005 di taratura e di pilotaggio.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070800.01.00 7:1 100-380 bar 350 bar 82 bar/turn 200 l/min 350 bar 1"G 9.5 kg
Pag. 07.02.03

Valvola di blocco bilanciata doppia in linea serie 165 CC


Dual overcenter valves in line "165 series CC"

L1 L L1

C1 C2 = =

L2 L3
HEX17
Y Y

H1
C1 C2

A B

=
H2

H
=
p (bar)

Y A B Y
SFIATO/ SFIATO/
CURVE CARATTERISTICHE AIR BLEED AIR BLEED
PERFORMANCE CURVES L5 L4
PRESSIONE / PRESSURE -

25
20 D (n.2)
15 A C1
10 C1 A

=
5

L6
0

=
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 52 51.5 48 112 19.5 35 65 11 43 8.5 1/2"G
151 52 51.5 48 112 19.5 30 55 8.5 38 8.5 3/8"G
L L1 L2 L3 L4 L5 L6 H H1 H2 D Y

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da A>C1 o B>C2 e il controllo A>C1 or B>C2 and the control
nelverso opposto tramite lazione in the opposite direction.
dellapressione di pilotaggio. The load is locked when the spool
Assicura il blocco del carico valve is in neutral position
con distributore in neutro o a pompa or the pump is not running
ferma (tralamento max. (max. leakage 5 drops/min).
5 gocce/min) e permette di scaricare Peaks of pressure can be relieved
i picchi di pressione se la spola only if the spool valve is equipped
del distributore munita di valvola with shock valves, to be set
antishocks tarata ad almeno 30 bar at least 30 bar below the valve
al di sotto della taratura della setting. The valve must be set
valvola. Tararead almeno 1,3 volte at 1.3 times the max. load induced
la pressionemassima indotta pressure. Back pressure
dal carico. Eventuali contropressioni downstream thevalve increases
CODICE ORDINAZIONE SEALING ORDERING sulloscarico aumentano solo only the required pilot pressure.
PIOMBATURA CODE la pressione di pilotaggio. The valve ts 2 airbleeds.
916001 La valvola ha 2 sati allaria.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070366.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070366.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070366.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070466.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
A070466.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
A070466.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
Pag. 07.02.04

Valvola di blocco bilanciata doppia in linea serie BRCC


Dual overcenter valves in line "BRCC series"

L1 L L1

L3 L2 L3
C1 C2
SFIATO/ L5 L4 L5 SFIATO/
AIR BLEED AIR BLEED
C1 C2

H2

H1
A B

H
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE A B
PERFORMANCE CURVES HEX 17 L6 L7
10
8 D (n.2)
6
4 B
2 C2
C2
S

B
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


124 61 104 10 69 27.5 45 34 30 60 34 14 6.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure
di pressione se la spola can be relieved only if
del distributore munita the spool valve is equipped
di valvola antishocks tarata with shock valves, to be set
ad almeno 30 bar al di sotto at least 30 bar below the valve
della taratura della valvola. setting. The valve must be set
Tarare ad almeno 1,3 volte at 1.3 times the max. load
la pressione massima indotta induced pressure.
dal carico. Eventuali Back pressure downstream
contropressioni sullo scarico the valve increases
CODICE ORDINAZIONE SEALING ORDERING aumentano solo la pressione only the required pilot pressure.
PIOMBATURA CODE di pilotaggio. La valvola The valve ts 2 air bleeds.
916001 ha 2 sati allaria.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070306.11.00 4.84:1 100-350 Bar 300 Bar 150 Bar/turn 45 L/min 500 Bar 3/8"g 1.6 Kg
A070306.12.00 6.83:1 100-450 Bar 300 Bar 210 Bar/turn 45 L/min 500 Bar 3/8"g 1.6 Kg
A070306.13.00 9.5:1 100-350 Bar 250 Bar 82 Bar/turn 45 L/min 500 Bar 3/8"g 1.6 Kg
Pag. 07.02.05

Valvola di blocco bilanciata in linea serie BRCC


Dual overcenter valves in line "BRCC series"

L1 L L1

L3 L2 L3
C1 C2
L5 L4 L5
SFIATO/ SFIATO/
AIR BLEED AIR BLEED

H3
C1 C2
V1 V2

H1

H2
H
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
14
12 V1 V2
10 HEX 17 L6 L7
8 D (n.2)
6
4 V2
2 C2 C2
V2
S

0 10 20 30 40 50 60 80
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


140 61 125 7.5 80 30 52 36 35 70 38 54 8 8.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the control
controllo nel verso opposto in the opposite direction. The
tramite lazione della pressione load is locked when the spool
di pilotaggio. Assicura il blocco valve is in neutral position or
del carico con distributore the pump is not running (max.
in neutro o a pompa ferma leakage 5 drops/min). Peaks of
(tralamento max. 5 gocce/min) pressure can be relieved only if
e permette di scaricare i picchi the spool valve is equipped
di pressione se la spola del with shock valves, to be set at
distributore munita di least 30 bar below the valve
valvola antishocks tarata setting. The valve must be set at
ad almeno 30 bar al di sotto 1.3 times the max. load induced
della taratura della valvola. pressure. Back pressure
Tarare ad almeno 1,3 volte downstream the valve
la pressione massima indotta increases only the required pilot
dal carico. Eventuali pressure. The valve ts 2 air
contropressioni sullo scarico bleeds.
CODICE ORDINAZIONE SEALING ORDERING aumentano solo la pressione
PIOMBATURA CODE di pilotaggio. La valvola ha 2
916001 sati allaria.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070406.11.00 4.84:1 100-350 Bar 350 Bar 150 Bar/turn 80 L/min 500 Bar 1/2"g 2.2 Kg
A070406.12.00 6.83:1 100-450 Bar 300 Bar 210 Bar/turn 80 L/min 500 Bar 1/2"g 2.2 Kg
A073906.11.00 4.84:1 100-350 Bar 250 Bar 150 Bar/turn 80 L/min 500 Bar M22x1.5 2.2 Kg
A073906.12.00 6.83:1 100-450 Bar 300 Bar 210 Bar/turn 80 L/min 500 Bar M22x1.5 2.2 Kg
Pag. 07.02.06

Valvola di blocco bilanciata doppia in linea serie BP


Dual overcenter valve in line "BP series"

C1 C2
L1 L L1

L3 L2

L5 L4

C1 C2

V1 V2

H
H1
H2
V1 V2
p (bar)

CURVE CARATTERISTICHE HEX5 L6 L7


PERFORMANCE CURVES
HEX17 D (n.2)
25
PRESSIONE / PRESSURE -

20
15 V1 C1
S

10 C1 V1
5

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B070461.08.00 140 ~54 125 7.5 61 39.5 20.5 99 35 70 60 35 8.5
COD. L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola relieved only with open
del distributore a centro centre spool valves.
aperto. Tarare ad almeno The valve must be set
1,3 volte la pressione massima at 1,3 times the max. load
indotta dal carico. Eventuali induced pressure. Back
contropressioni sullo scarico pressure downstream
aumentano la pressione the valve increases
di taratura e di pilotaggio the setting and the
richiesta per pilotare la valvola. requested pilot pressure.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B070461.08.00 10:1 100-350 bar 350 bar 93 bar/turn 60 l/min 350 bar 1/2"G 1.25 kg
Pag. 07.02.07A

Valvola di blocco bilanciata doppia in linea serie BRCC


Dual overcenter valve in line "BRCC series"

L1 L L1
C1 C2 HEX5 L3 L2
HEX17

H3
C1 C2

A B

H2
H
p (bar)

H1
CURVE CARATTERISTICHE
PERFORMANCE CURVES A B
SFIATO/AIR BLEED L4 L5 SFIATO/AIR BLEED
PRESSIONE / PRESSURE -

28
24 L6 L7
20
16 D (n.2)
12
B
8 C2
C2
=

4 B
S

0
=

20 40 60 80 100 120 140


PORTATA / FLOW - Q (l/min)

*Corpo in acciaio / Steel body


175 ~75 107 34 62.5 50 155 10 40 90 38 70 10 10.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola relieved only if the spool valve
del distributore munita is equipped with shock valves,
di valvola antishocks tarata to be set at least 30 bar
ad almeno 30 bar al di sotto below the valve setting.
della taratura della valvola. The valve must be set
Tarare ad almeno 1,3 volte at 1.3 times the max.
la pressione massima indotta load induced pressure.
dal carico. Eventuali Back pressure downstream
contropressioni sullo scarico the valve increases only
CODICE ORDINAZIONE SEALING ORDERING aumentano solo la pressione the required pilot pressure.
PIOMBATURA CODE di pilotaggio. La valvola The valve ts 2 air bleeds.
916005 ha 2 sati allaria.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
* A070606.11.00 4.4:1 100-350 bar 300 bar 90 bar/turn 140 l/min 500 bar 3/4"G 4.6 kg
* A070606.12.00 8.2:1 100-450 bar 350 bar 90 bar/turn 140 l/min 500 bar 3/4"G 4.6 kg
B070606.11.00 4.4:1 100-350 bar 300 bar 90 bar/turn 140 l/min 350 bar 3/4"G 4.6 kg
B070606.12.00 8.2:1 100-450 bar 300 bar 90 bar/turn 140 l/min 350 bar 3/4"G 4.6 kg
Pag. 07.02.07B

Valvola di blocco bilanciata doppia in linea serie BP


Dual overcenter valve in line "BP series"

C1 C2 L1 L L1
L3 L2

L5 L4

H1
C1 C2

=
V1 V2

H
=
V1 V2
p (bar)

CURVE CARATTERISTICHE
L6 L7
PERFORMANCE CURVES
28 HEX5
PRESSIONE / PRESSURE -

24 HEX17
D (n.2)
20
16

=
12
V2
8

S
C2 V2 C2
4

=
0 20 40 60 80 100 120 140
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B070661.01.00 155 ~58 135 10 74 40.5 22 111 45 90 10 8.5
COD. L L1 L2 L3 L4 L5 L6 L7 S H H1 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min ).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola del relieved only with open
distributore a centro aperto. centre spool valves.
Tarare ad almeno 1,3 volte la The valve must be set
pressione massima indotta dal at 1,3 times the max.
carico. Eventuali contropressioni load induced pressure.
sullo scarico aumentano la Back pressure downstream
CODICE ORDINAZIONE SEALING ORDERING pressione di taratura e di the valve increases
PIOMBATURA CODE pilotaggio richiesta the setting and the
916005 per pilotare la valvola. requested pilot pressure.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure

B070661.01.00 10:1 100-350 bar 210 bar 74 bar/turn 140 l/min 350 bar 3/4"G 2.2 kg
Pag. 07.02.07C

Valvola di balanciamento doppio eetto, serie 210 cc


Dual overcenter valve "210 cc series"

L1 L L1

L2
C2 C1

L4

L3
L5 HEX24
L6
V2 V1
H1 H

H2
C2 C1

=
S
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25 =
V2 V1
PRESSIONE / PRESSURE -

20
15 S1 D(n 2)
V1 S2 2
10
C1 C1 1 C2
5
V1
0 25 50 75 100 125 150 C1

PORTATA / FLOW - Q (l/min)

S3
Corpo in alluminio / Aluminium body
B070466.01.00 130 46 20 29 70 39 91 70 82 48 ~216 110 10 10 8.5
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di bilanciamento a Dual overcenter valve ,


doppio eetto , consigliata per suggested for use with close
distributori con spole a centro centre spools . To be connected
chiuso. Collegare allimpianto as shown . The valve allows: free
come da schema . La valvola ow from V2 to C2 and from V1
permette: usso libero da V2 to C1, to hold the load with
verso C2 e da V1 verso C1, spool in neutral position or with
sostentamento del carico the pump not running,
con distributore in neutro o a controlled movement when
pompa ferma, controllo del pilot pressure is applied, relief
movimento di discesa del carico function against overpressure in
a seguito del pilotaggio della the cylinder.
valvola pilotaggio,protezione da
sovrapressioni nel cilindro.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B070466.01.00 4:1 100-350 Bar 350 Bar 110 Bar/turn 150 L/min 350 Bar 1/2"g 2.18 Kg
Pag. 07.03.01

Valvola di blocco bilanciata doppia angiabile serie 165


Flangeable dual overcenter valve "165 series"

L1 L L1

L2 L3

M1 C1 C2 M L6
X Y

H2
M2
M

C1

=
C2

H1
V1 V2 H
=
PRESSIONE / PRESSURE - p (bar)

V2 V1
CURVE CARATTERISTICHE HEX 13 M2 M1
Y X X Y SOLO/ONLY:
PERFORMANCE CURVES HEX 4
25 L5 L4 -A070371.01.00
20 -A070371.02.00
D1 -A070371.03.00
15 V1 C1 O-RING D (n.4)
10 C1 V1
5
=
L7

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)


Corpo in acciaio / Steel body
151 ~42 51.5 48 112 19.5 30 35 65 30 5 8.5 9 1/2"G 1/4"G OR 3043 10.78x2.62
151 ~42 51.5 48 112 19.5 30 30 55 30 5 8.5 9 3/8"G 1/4"G OR 3043 10.78x2.62
L L1 L2 L3 L4 L5 L6 L7 H H1 H2 D D1 Y X O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the
controllo nel verso opposto control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve is in
del carico con distributore in neutral position or the pump is
neutro o a pompa ferma not running (max leakage 5
(tralamento max. 5 gocce/min) drops/min). Peaks of pressure
e permette di scaricare i picchi di can be relieved only with open
pressione se la spola del centre spool valves. The valve
distributore a centro aperto. must be set at 1,3 times the
Tarare ad almeno 1,3 volte la max. load induced pressure.
pressione massima indotta Back pressure downstream the
dal carico. Eventuali valve increases the setting and
contropressioni sullo scarico the requested pilot pressure.
CODICE ORDINAZIONE SEALING ORDERING aumentano la pressione
PIOMBATURA CODE di taratura e di pilotaggio
916003 richiesta per pilotare la valvola.

Codice Rapporto Di Campo Di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard Per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070371.01.00 2.7:1 80-350 Bar 300 Bar 85 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070371.02.00 4.3:1 100-350 Bar 350 Bar 135 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070371.03.00 8.8:1 100-350 Bar 350 Bar 90 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070471.01.00 2.7:1 80-350 Bar 300 Bar 85 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
A070471.02.00 4.3:1 100-350 Bar 350 Bar 135 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
A070471.03.00 8.8:1 100-350 Bar 350 Bar 90 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
Pag. 07.03.01A

Valvola di blocco bilanciata doppia angiabile serie 140


Flangeable dual overcenter valve "140 series"

L1 L L1
L3 L2 L3

L4
M C2 C1 = =

H1
M
C1

=
C2

H2
H
V2 V1

=
=
V2 V1

HEX4
PRESSIONE / PRESSURE - p (bar)

L6 L5 L6
CURVE CARATTERISTICHE
PERFORMANCE CURVES HEX13
D1
25
20 V1 O-RING D (n.4)
15 C1
10 C1
=

V1
S

5
=

0 5 10 15 20 25 30
PORTATA / FLOW - Q (l/min)

Corpo in acciaio/Steel body


138 ~42 38 50 28 92 23 24.5 45 5 28 6.5 6 OR 112 9.92x2.62
L L1 L2 L3 L4 L5 L6 S H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the
controllo nel verso opposto control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve is in
del carico con distributore in neutral position or the pump is
neutro o a pompa ferma not running (max leakage 5
(tralamento max. 5 gocce/min) drops/min). Peaks of pressure
e permette di scaricare i picchi can be relieved only with open
di pressione se la spola del centre spool valves. The valve
distributore a centro aperto. must be set at 1,3 times the
Tarare ad almeno 1,3 volte la max. load induced pressure.
pressione massima indotta Back pressure downstream the
dal carico. Eventuali valve increases the setting and
contropressioni sullo scarico the requested pilot pressure.
CODICE ORDINAZIONE SEALING ORDERING aumentano la pressione
PIOMBATURA CODE di taratura e di pilotaggio
916003 richiesta per pilotare la valvola.

Codice Rapporto Di Campo Di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard Per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070271.22.00 4.1:1 100-350 Bar 300 Bar 180 Bar/turn 30 L/min 500 Bar 1/4"g 1.45 Kg
Pag. 07.03.02

Valvola di blocco bilanciata doppia angiabile serie 165


Flangeable dual overcenter valve "165 series"

L1 L L1

L2 L3

C1 C2

=
C1 C2

H1
H
A B

=
=
HEX13
PRESSIONE / PRESSURE - p (bar)

Y A Y B
CURVE CARATTERISTICHE HEX4
PERFORMANCE CURVES L5 L4
25
20
D1 (n.2)
15 A C1 O-RING
D (n.4)
10 C1 A
5
=
L6

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 ~42 51.5 48 112 19.5 35 65 40 8.5 9 1/2"G OR 3043 10.77x2.62
151 ~42 51.5 48 112 19.5 30 55 40 8.5 9 3/8"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 L6 H H1 D D1 Y O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da A>C1 o B>C2 e il A>C1 or B>C2 and the control in
controllo nel verso opposto the opposite direction. The load
tramite lazione della pressione is locked when the spool valve is
di pilotaggio. Assicura il blocco in neutral position or the pump
del carico con distributore is not running (max leakage 5
in neutro o a pompa ferma drops/min). Peaks of pressure
(tralamento max. 5 gocce/min) can be relieved only with open
e permette di scaricare i picchi centre spool valves. The valve
di pressione se la spola del must be set at 1,3 times the
distributore a centro aperto. max. load induced pressure.
Tarare ad almeno 1,3 volte la Back pressure downstream the
pressione massima indotta dal valve increases the setting and
carico. Eventuali contropressioni the requested pilot pressure.
sullo scarico aumentano la
CODICE ORDINAZIONE SEALING ORDERING pressione di taratura e di
PIOMBATURA CODE pilotaggio richiesta
916003 per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070381.01.00 2.7:1 80-350 Bar 300 Bar 85 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070381.02.00 4.3:1 100-350 Bar 350 Bar 135 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070381.03.00 8.8:1 100-350 Bar 350 Bar 90 Bar/turn 45 L/min 500 Bar 3/8"g 1.7 Kg
A070481.01.00 2.7:1 80-350 Bar 300 Bar 85 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
A070481.02.00 4.3:1 100-350 Bar 350 Bar 135 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
A070481.03.00 8.8:1 100-350 Bar 350 Bar 90 Bar/turn 60 L/min 500 Bar 1/2"g 2.1 Kg
Pag. 07.03.02A

Valvola di blocco bilanciata doppia angiabile serie 140


Flangeable dual overcenter valve "140 series"

L1 L L1

C1
L3 L2 L3
C2

=
C2 C1

=
H1
H

=
=
V2 V1

V2 V1
HEX13
L5 L4 L5
p (bar)

HEX4
CURVE CARATTERISTICHE
PERFORMANCE CURVES
25 D1 (n.2)
PRESSIONE / PRESSURE -

20 V1 O-RING D (n.4)
15 C1
10
=

C1
S

V1
5
=

0 5 10 15 20 25 30
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


138 ~42 38 50 92 23 24.5 45 28 6.5 6 OR 112 9.92x2.62
L L1 L2 L3 L4 L5 S H H1 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max leakage 5 drops/min ).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola del relieved only with
distributore a centro aperto. open centre spool valves.
Tarare ad almeno 1,3 volte The valve must be set
la pressione massima indotta at 1,3 times the max.
dal carico. Eventuali load induced pressure.
contropressioni sullo scarico Back pressure downstream
CODICE ORDINAZIONE SEALING ORDERING aumentano la pressione the valve increases the
PIOMBATURA CODE di taratura e di pilotaggio setting and the requested
916003 richiesta per pilotare la valvola. pilot pressure.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070281.22.00 4.1:1 100-350 bar 300 bar 180 bar/turn 30 l/min 500 bar 1/4"G 1.1 kg
Pag. 07.03.02B

Valvola di blocco bilanciata doppia angiabile serie 165


Flangeable dual overcenter valve "165 series"

A1 P T B1

=
S
=
HEX4
A P T B D (n.4) O-RING HEX13

CURVE CARATTERISTICHE L1
p (bar)

PERFORMANCE CURVES L
25 L2
PRESSIONE / PRESSURE -

20 P

=
=
15 A = =
A B
H2

H3

H1

H
A1
A1

=
10

=
T
5 A L3
L4
0 10 20 30 40 50 L5
L6
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 235 75.5 12.7 21.5 30.2 40.5 59 45 32.5 31 5.1 5.5 OR 2037 9.25x1.78
L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 D O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>A1 o B>B1 from A>A1 or B>B1
e il controllo nel verso opposto and the control in the
tramite lazione della pressione opposite direction.
di pilotaggio. Assicura il blocco The load is locked when
del carico con distributore the spool valve is in neutral
in neutro o a pompa ferma position or the pump
(tralamento max. 5 gocce/min) is not running (max leakage
e permette di scaricare i picchi 5 drops/min ). Peaks of
di pressione se la spola del pressure can be relieved
distributore a centro aperto. only with open centre
Tarare ad almeno 1,3 volte spool valves. The valve
la pressione massima indotta must be set at 1,3 times
dal carico. Eventuali the max. load induced pressure.
contropressioni sullo scarico Back pressure downstream
CODICE ORDINAZIONE SEALING ORDERING aumentano la pressione the valve increases
PIOMBATURA CODE di taratura e di pilotaggio the setting and the
916003 richiesta per pilotare la valvola. requested pilot pressure.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A072381.01.00 2.7:1 80-350 bar 300 bar 85 bar/turn 45 l/min 350 bar ang. 6.5 1.1 kg
A072381.02.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 350 bar ang. 6.5 1.1 kg
A072381.03.00 8.8:1 100-350 bar 350 bar 90 bar/turn 45 l/min 350 bar ang. 6.5 1.1 kg
Pag. 07.03.02C

Calvola di blocco bilanciata doppia angiabile serie 140


Flangeable dual overcenter valve "140 series"

HEX13
= =

H2
HEX4

C2 C1

H1
H
H3
H4

H2
L3
L2
V2 V1 L1 L L1

O-RING

S
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25 F3 F4
F1

20 F2
15 V1
F5

10 C1
1

D (n2)
5 V1 C
F

0
4 8 12 16 20
F1

PORTATA / FLOW - Q (l/min) F2

Corpo in acciaio / Steel body


A070281.24.00 95 35 72 23 39.5 50 38 6 32.5 17.5 17 10.5 4.5 9 43 16.5 6.5 OR 2037 9.25x1.78
COD. L L1 L2 L3 S H H1 H2 H3 H4 F F1 F2 F3 F4 F5 D O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da V1>C1 o V2>C2 e il controllo nel V1>C1 or V2>C2 and the control
verso opposto tramite lazione della in the opposite direction. The load
pressione di pilotaggio. Assicura il is locked when the spool valve is in
blocco del carico con distributore in neutral position or the pump is not
neutro o a pompa ferma (tralamento running (max leakage 5 drops/min).
max. 5 gocce/min) e permette di Peaks of pressure can be relieved
scaricare i picchi di pressione se la spola only with open centre spool valves.
del distributore a centro aperto. The valve must be set at 1,3 times
Tarare ad almeno 1,3 volte la pressione the max. load induced pressure.
massima indotta dal carico. Eventuali Back pressure downstream
contropressioni sullo scarico aumentano the valve increases the setting
la pressione di taratura e di pilotaggio and the requested pilot pressure.
richiesta per pilotare la valvola.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 1/4"G
A070281.24.00 4.1:1 200-450 bar 390 bar 215 bar/turn 20 l/min 500 bar 1.4 kg
C1-C2 5
Pag. 07.03.02D

Valvola di blocco bilanciata doppia angiabile serie 140


Flangeable dual overcenter valve "140 series"

C1 C2
3
2
1 2

V1 V2

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25
20 V2
15 C2
10
2
5 V2 C

0 5 10 15 20 25 30

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


87 ~35.3 65 19.5 40 8 69.5 6 70 17 37 37 58 6 19 32 6.5 10.5 6 OR 2037 9.19x2.62
L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 H4 H5 H6 H7 D D1 D2 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da V1>C1 o V2>C2 e il controllo V1>C1 or V2>C2 and the control
nel verso opposto tramite lazione in the opposite direction. The load
della pressione di pilotaggio. is locked when the spool valve is
Assicura il blocco del carico con in neutral position or the pump is
distributore in neutro o a pompa not running (max leakage 5
ferma (tralamento max. 5 drops/min ). Peaks of pressure can
gocce/min) e permette di be relieved only with open centre
scaricare i picchi di pressione se la spool valves.
spola del distributore a centro The valve must be set at 1,3 times
aperto. Tarare ad almeno 1,3 volte the max. load induced pressure.
la pressione massima indotta dal At C1 line there is an additional
carico. Sul ramo C1 presente una pilot operated check valve to
valvola di blocco pilotata ensure a perfect sealing. Back
supplementare per garantire pressure downstream the valve
una tenuata perfetta. Eventuali increases the setting and the
contropressioni sullo scarico requested pilot pressure.
CODICE ORDINAZIONE SEALING ORDERING
PIOMBATURA CODE aumentano la pressione di
taratura e di pilotaggio
916003 richiesta per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
1,2 4.1:1 150-400 bar 390 bar 110 bar/turn
B070281.06.00 3 3:1 - - - 30 l/m 400 bar 1/4G 1.3 Kg
Pag. 07.04.01

Valvola di blocco bilanciata doppia angiabile serie 165 CC


Flangeable dual overcenter valve "165 CC series"

L1 L L1
M C1 C2 M1
L2 L3
M2
L6
SFIATO/ SFIATO/
X Y

H2
AIR BLEED AIR BLEED
M2 C2
A B

=
C1

=
H1
H

=
=
p (bar)

CURVE CARATTERISTICHE A B
PERFORMANCE CURVES HEX17 M M1
25 Y X X Y
HEX5
PRESSIONE / PRESSURE -

20 L5 L4
15 A C1 D1
A D (n.4)
10 C1 O-RING

5
=
S

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 42 51.5 48 112 19.5 30 35 65 30 5 8.5 9 1/2"G 1/4"G OR 3043 10.78x2.62
151 42 51.5 48 112 19.5 30 30 55 30 5 8.5 9 3/8"G 1/4"G OR 3043 10.78x2.62
L L1 L2 L3 L4 L5 L6 S H H1 H2 D D1 Y X O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free


da A>C1 o B>C2 e il controllo ow from A>C1 or B>C2
nel verso opposto tramite lazione and the control
della pressione di pilotaggio. in the opposite direction.
Assicura il blocco del carico The load is locked when
con distributore in neutro the spool valve is in neutral
o a pompa ferma (tralamento position or the pump is not
max. 5 gocce/min) e permette running (max. leakage
di scaricare i picchi di pressione 5 drops/min). Peaks of pressure
se la spola del distributore can be relieved only if the spool
munita di valvola antishocks valve is equipped with shock
tarata ad almeno 30 bar al di sotto valves, to be set at least 30 bar
della taratura della valvola. below the valve setting.
Tarare ad almeno 1,3 volte The valve must be set at 1.3 times
la pressione massima indotta the max. load induced pressure.
dal carico. Eventuali contropressioni Back pressure downstream
CODICE ORDINAZIONE SEALING ORDERING sullo scarico aumentano solo the valve increases only
PIOMBATURA CODE la pressione di pilotaggio. the required pilot pressure.
916005 La valvola ha 2 sati allaria. The valve ts 2 air bleeds.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070376.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070376.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070376.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070476.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
A070476.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
A070476.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
Pag. 07.04.02

Valvola di blocco bilanciata doppia angiabile serie 165 CC


Flangeable dual overcenter valve "165 cc series"

L1 L L1
C1 C2
L2 L3
SFIATO/ SFIATO/
AIR BLEED AIR BLEED

=
A B C1 C2

=
H

H1
=
=
A B
p (bar)

CURVE CARATTERISTICHE Y Y
PERFORMANCE CURVES HEX17
25 L5 L4
PRESSIONE / PRESSURE -

20 D1 (n.2)
15 A C1 D (n.4) O-RING
A
10 C1
=

5
S
=

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 52 51.5 48 112 19.5 35 65 40 8.5 9 1/2"G OR 3043 10.77x2.62
151 52 51.5 48 112 19.5 30 55 40 8.5 9 3/8"G OR 3043 10.77x2.62
L L1 L2 L3 L4 L5 S H H1 D D1 Y O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure can be
di pressione se la spola relieved only if the spool valve
del distributore munita is equipped with shock valves,
di valvola antishocks tarata to be set at least 30 bar
ad almeno 30 bar al di sotto below the valve setting.
della taratura della valvola. The valve must be set
Tarare ad almeno 1,3 volte at 1.3 times the max. load
la pressione massima indotta induced pressure.
dal carico. Eventuali contropressioni Back pressure downstream
CODICE ORDINAZIONE SEALING ORDERING sullo scarico aumentano solo the valve increases only
PIOMBATURA CODE
la pressione di pilotaggio. the required pilot pressure.
916001 La valvola ha 2 sati allaria. The valve ts 2 air bleeds.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070386.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070386.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070386.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070486.01.00 2.7:1 80-350 bar 300 bar 105 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
A070486.02.00 4.3:1 100-350 bar 350 bar 160 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
A070486.03.00 8.8:1 100-350 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
Pag. 07.05.01

Valvola di blocco bilanciata in linea con regolatore di usso serie BR


Dual overcenter valve in line with ow regulator "BR series"

L1 L L1

C1 C2
L3 L2

L5 L4
C1 C2

H1
S1 S2

A B
S1 S2

H
H2
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES L6
A L7
B
HEX24 HEX10
10
PRESSIONE / PRESSURE -

8
D (n.2)
6
4 B
=

2 C2 C2
S

B
0
=

10 20 30 40
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


124 ~52 104 10 69 27.5 45 34 30 60 14 26 6.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2 and
e il controllo nel verso opposto the control on the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. Leakage 5 drops/min).
e permette di scaricare un picco Peaks of pressure can be
di pressione se la spola del relieved only with open centre
distributore a centro aperto. spool valves. The valve
Tarare ad almeno 1,3 volte must be set at 1,3 times
la pressione massima indotta the max. Load induced
dal carico. Eventuali pressure. Back pressure
contropressioni sullo scarico downstream the valve
aumentano la pressione increases the setting
di taratura e di pilotaggio and the requested pilot
richiesta per pilotare la valvola. pressure. The two restrictors,
I 2 strozzatori bidirezionali in both ow directions,
permettono di limitare allow to regulate the ow,
CODICE ORDINAZIONE SEALING ORDERING la velocit massima di discesa but a higher pilot
PIOMBATURA CODE
carico, ma innalzano la pressione pressure is required.
916001 richiesta per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070311.00.00 4.84:1 100-350 bar 180 bar 125 bar/turn 40 l/min 500 bar 3/8"G 1.8 kg
Pag. 07.05.02

Valvola di blocco bilanciata in linea con regolatore di usso serie BR


Dual overcenter valve in line with ow regulator "BR series"

L1 L L1
C1 C2

L3 L2 L3

H3
S1 S2

A B C1 C2
S1 S2

H2
H
H1
p (bar)

CURVE CARATTERISTICHE A B
PERFORMANCE CURVES HEX10
HEX24 L4 L5
10
PRESSIONE / PRESSURE -

L6 L7
8
6 D (n.2)
A
4
C1 C1
2
=

A
S

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


140 ~52 80 30 52 36 125 7.5 35 70 32 54 8 8.5
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control on the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. Leakage 5 drops/min).
e permette di scaricare un picco Peaks of pressure can be
di pressione se la spola del relieved only with open centre
distributore a centro aperto. spool valves. The valve must
Tarare ad almeno 1,3 volte be set at 1,3 times the max.
la pressione massima indotta Load induced pressure.
dal carico. Eventuali Back pressure downstream
contropressioni sullo scarico the valve increases the setting
aumentano la pressione and the requested pilot
di taratura e di pilotaggio pressure. The two restrictors,
richiesta per pilotare la valvola. in both ow directions,
I 2 strozzatori bidirezionali allow to regulate the ow,
permettono di limitare la but a higher pilot
CODICE ORDINAZIONE SEALING ORDERING velocit massima di discesa pressure is required.
PIOMBATURA CODE carico, ma innalzano la pressione
916001 richiesta per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070411.01.00 4.84:1 100-350 bar 200 bar 125 bar/turn 60 l/min 500 bar 1/2"G 2.2 kg
Pag. 07.05.03

Valvola di blocco bilanciata in linea con regolatore di usso serie 165


Dual overcenter valve in line with ow regulator "165 series"

L1
C1 C2 L
L3 L2
L4 L5
HEX22

VS1 VS2 HEX13


C1 C2
A B

H1
H

H2
H3
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES A B
HEX24 L6 L7
10
PRESSIONE / PRESSURE -

8 D (n.2)
6
A
S1

4
C1
2 C1
S2
S

A
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


151 ~235 135 8 51.5 48 22 107 50 15 20 50 ~73 41.5 22.5 6.5
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free


libero da A>C1 o B>C2 ow from A>C1 or B>C2
e il controllo nel verso opposto and the control in the
tramite lazione della pressione opposite direction.
di pilotaggio. Assicura il blocco The load is locked
del carico con distributore when the spool valve
in neutro o a pompa ferma is in neutral position
(tralamento max. 5 gocce/min) or the pump is not running
e permette di scaricare (max. Leakage 5 drops/min).
i picchi di pressione se la spola Peaks of pressure can be
del distributore a centro aperto. relieved only with
Tarare ad almeno 1,3 volte open centre spool valves.
la pressione massima indotta The valve must be set
dal carico. Eventuali at 1.3 times the max.
contropressioni sullo scarico load induced pressure.
aumentano la pressione Back pressure
di taratura e di pilotaggio downstream the valve
richiesta per pilotare la valvola. increases the setting
I 2 strozzatori unidirezionali and the requested
permettono di limitare pilot pressure. The two
la velocit massima di discesa one-way restrictors
CODICE ORDINAZIONE SEALING ORDERING del carico, ma innalzano allow to regulate
PIOMBATURA CODE
la pressione richiesta the ow, but a higher
916003 per pilotare la valvola. pilot pressure is required.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070311.03.00 4.3:1 100-350 bar 200 bar 135 bar/turn 45 l/min 350 bar 3/8"G 1.2 kg
Pag. 07.05.04

Valvola di blocco bilanciata doppia in linea con regolazione di usso serie 165
Dual overcenter valve in line with ow regulator "165 series"

HEX4

L1
C1 C2 HEX13

L2
V1

F1

H
C1

L3
F
V1 V2

L
C2
CURVE CARATTERISTICHE
p (bar)

F1
PERFORMANCE CURVES
25 V2
20
PRESSIONE / PRESSURE -

L2
15 V1 C1

C1 V1

L1
10
H2
5

0 H1
10 20 30 40 50 60
D (n2)

S1
PORTATA / FLOW - Q (l/min)

S
S2

Corpo in acciaio / Steel body S3

A070351.01.00 151 70.6 19.5 112 30 15 27.5 55 75.5 38 8.5 48 51.5 8.5
COD. L L1 L2 L3 S S1 S2 S3 H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow


da V1>C1 o V2>C2 e il controllo from V1>C1 or V2>C2
nel verso opposto tramite lazione and the control in the opposite
della pressione di pilotaggio. direction. The load is locked
Assicura il blocco del carico con when the spool valve is in neutral
distributore in neutro o a pompa position or the pump is not running
ferma (tralamento max. (max leakage 5 drops/min). Peaks
5 gocce/min) e permette di scaricare of pressure can be relieved only
i picchi di pressione se la spola del with open centre spool valves.
distributore a centro aperto. The valve must be set at 1,3 times
Tarare ad almeno 1,3 volte la the max. load induced pressure.
pressione massima indotta dal Back pressure downstream the
carico. Eventuali contropressioni valve increases the setting
sullo scarico aumentano la pressione and the requested pilot pressure.
di taratura e di pilotaggio richiesta
per pilotare la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070351.01.00 4.2:1 10-210 bar 170 bar 55 bar/turn 45 l/min 350 bar 3/8"G 1.9 kg
Pag. 07.05.05

Valvola di blocco bilanciata doppia in linea con regolazione di usso serie 165
Dual overcenter valve in line with ow regulator "165 series"

3 1 2

H2
C1 C2

H1
2

H
2
2 L2 1 3
1 1 L1 HEX17
HEX5
F1 F

S1
3 3

V1 V2

S
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

25 L HEX4
20 L4 D (n2)
HEX13
C1
15 V1
C1 V1
10

H1
5

H2
10 20 30 40 50 60 L6 L3 L5

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B070361.15.00 100 79.5 20.5 51 49 51 71 70 5.5 70 51 19 70 15 6.5
COD. L L1 L2 L3 L4 L5 L6 S S1 H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow


da V1>C1 o V2>C2 e il controllo from V1>C1 or V2>C2 and the
nel verso opposto tramite lazione control in the opposite direction.
della pressione di pilotaggio. The load is locked when the spool
Assicura il blocco del carico valve is in neutral position
con distributore in neutro or the pump is not running
o a pompa ferma (tralamento (max leakage 5 drops/min).
max. 5 gocce/min) e permette Peaks of pressure can be relieved
di scaricare i picchi di pressione only with open centre spool
se la spola del distributore valves. The valve must be set
a centro aperto. Tarare at 1,3 times the max. load induced
ad almeno 1,3 volte la pressione pressure. Flow regulation
massima indotta dal carico. to the tank. Line protection
CODICE ORDINAZIONE SEALING ORDERING Regolazione della portata allo with cross relief valves.
PIOMBATURA CODE scarico. Protezione della linea
916005 con valvole di massima incrociate.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 0-250 bar 160 bar 55 bar/turn
B070361.15.00 1:1 45 l/min 350 bar 3/8"G 1.9 kg
2 100-350 bar 220 bar 110 bar/turn
Pag. 07.06.01

Valvola di blocco bilanciata doppia in linea serie 165


Dual overcenter valve in line "165 series"

L1 L L1
= =
C1 F C2
L2 L3
Y Y

H1
C1 C2

=
A B

H
p (bar)

=
CURVE CARATTERISTICHE
A F B
PERFORMANCE CURVES
25 HEX17 Y X Y
PRESSIONE / PRESSURE -

20 L5 L4
HEX5
15 A C1
A D
10 C1

5
=
S

0 10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


151 ~42 51.5 48 112 19.5 35 65 11 8.5 1/4"G 1/2"G
151 ~42 51.5 48 112 19.5 30 55 8.5 8.5 1/4"G 3/8"G
L L1 L2 L3 L4 L5 S H H1 D X Y

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da A>C1 o B>C2 from A>C1 or B>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. Leakage 5 drops/min).
e permette di scaricare i picchi Peaks of pressure
di pressione se la spola can be relieved only
del distributore a centro aperto. with open centre spool valves.
Tarare ad almeno 1.3 volte The valve must be set
la pressione massima indotta at 1.3 times the max. load
dal carico. Eventuali pressure. Back pressure
contropressioni sullo scarico downstream the valve
aumentano la pressione increases the setting
di taratura e di pilotaggio and the requested pilot
richiesta per pilotare la valvola. pressure. The inside shuttle
La valvola selettrice valve and the port F allow
CODICE ORDINAZIONE SEALING ORDERING incorporata e lattacco F to drive an additional external
PIOMBATURA CODE
permettono di pilotare brake for brake opening.
916003 un eventuale freno esterno.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070361.51.00 4.3:1 100-350 bar 350 bar 135 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070361.52.00 11:1 100-450 bar 350 bar 115 bar/turn 45 l/min 500 bar 3/8"G 1.7 kg
A070461.51.00 4.3:1 100-350 bar 350 bar 135 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
A070461.52.00 11:1 100-450 bar 350 bar 115 bar/turn 60 l/min 500 bar 1/2"G 2.1 kg
Pag. 07.06.02

Valvola di bilanciamento doppio eetto, serie 165


Dual overcenter valve "165 series"

1 2
C1 C2
C1

H2
H1
1 1

H
2 C2
L1 L2 HEX13
L 1
2 HEX4

S2
S1
2

S
V1 V2

D
G
HEX4

(n
CURVE CARATTERISTICHE F1 F

2
PRESSIONE / PRESSURE - p (bar)

)
PERFORMANCE CURVES HEX13
25 L7

20 V2

H3
15 V1 C1

C1 V1
10
H3

5 V1
L5 L4 L6
0
10 20 30 40 50 60 L3
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A070461.59.00 100 46.5 7 177 51 24.5 32.4 38.5 70 38 19 70 51 18 18 70 15 5.5 6.5
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 F F1 G D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual overcenter valve with dual


doppia con valvola di massima relief valve cross-line.
doppia incrociata.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte
Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 150-450 bar 425 bar 135 bar/turn
A070461.59.00 4.25:1 60 l/min 450 bar 1/2"G 3.5 kg
2 50-170 bar 170 bar 50 bar/turn
Pag. 07.06.03

Valvola di blocco bilanciata doppia in linea serie 165


Dual overcenter valve in line "165 series"

HEX13

HEX4 F3 D (n2)
C1 C2
C3
M

=
3

=
V2 V1

1 2 F1 F F2

HEX5

H2

H3
V1 V2

H4
H1
CURVE CARATTERISTICHE H
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25
H2

20 L1
HEX17
15 V1 C1 L
10 C1 V1
5 C2 C1
=

0
S

10 20 30 40 50 60
=

PORTATA / FLOW - Q (l/min)

~L5 L3 L2 L3 ~L4

Corpo in acciaio / Steel body


A070461.57.00 151 75.5 48 51.5 ~51.3 ~42 35 90 70 10 29 30 109 20 22 51.5 8.5
COD. L L1 L2 L3 L4 L5 S H H1 H2 H3 H4 F F1 F2 F3 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da V1>C1 o V2>C2 e il controllo A>C1 or B>C2 and the control
nel verso opposto tramite lazione in the opposite direction.
della pressione di pilotaggio. The load is locked when the spool
Assicura il blocco del carico valve is in neutral position or the
con distributore in neutro o a pump is not running (max leakage
pompa ferma (tralamento max. 5 5 drops/min ). Peaks of pressure
gocce/min) e permette di scaricare can be relieved only with open
i picchi di pressione se la spola centre spool valves. The valve must
del distributore a centro aperto. be set at 1,3 times the max. load
Tarare ad almeno 1,3 volte induced pressure. Back pressure
la pressione massima indotta downstream the valve increases
dal carico. Eventuali contropressioni the setting and the requested pilot
sullo scarico aumentano pressure. The C2 line is protected
CODICE ORDINAZIONE SEALING ORDERING la pressione di taratura e di by the pressure relief valve.
PIOMBATURA CODE pilotaggio. La linea C2 protetta
916003 - 916005 dalla valvola di massima.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Code Setting Increase Flow Pressure
1-2 100-350 bar 300 bar 135 bar/turn V1, V2, C1, C2 1/2"G
A070461.57.00 4.25:1 60 l/min 400 bar 3.4 kg
3 100-350 bar 260 bar 110 bar/turn M 1/4"G
Pag. 07.06.04

Valvola di blocco bilanciata doppia in linea serie BRCC


Dual overcenter valve in line "BRCC series"

SFIATO/AIR BLEED SFIATO/AIR BLEED


T2

H3
V1 V2
C1 C2

H4
L3 L2
3 1 2

L1 L L1

D (n2)
S3
HEX17
T V1 V2
HEX5

S1
S
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
28 H H1

S2
24 F1 F
20
16 L5 L4
Ovc 1
12
V2

H2
8 C2
4 C2 V2
0
20 40 60 80 100 120 140 C1 C2
H3

PORTATA / FLOW - Q (l/min)


p(C2 - V2) = p(C1 - T) Ovc 2
H4

Ovc 3

Corpo in acciaio / Steel body


A070606.13.00 175 ~84 50 62.5 107 34 90 70 10 7.5 80 4.5 20 40 20 155 10 10.5
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 F F1 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow


da V1>C1 o V2>C2 e il controllo from V1>C1 or V2>C2 and the
nel verso opposto tramite control in the opposite direction.
lazione della pressione di The load is locked when the spool
pilotaggio. Assicura il blocco valve is in neutral position
del carico con distributore or the pump is not running
in neutro o a pompa ferma (max. leakage 5 drops/min).
(tralamento max. 5 gocce/min) Peaks of pressure can be relieved
e permette di scaricare i picchi only if the spool valve is equipped
di pressione se la spola with shock valves, to be set
del distributore munita di valvola at least 30 bar below the valve
antishocks tarata ad almeno setting. The valve must be set
30 bar al di sotto della taratura at 1.3 times the max. load
della valvola. Tarare ad almeno induced pressure.
1,3 volte la pressione massima Back pressure downstream
indotta dal carico. Eventuali the valve increases only
CODICE ORDINAZIONE SEALING ORDERING contropressioni sullo scarico the required pilot pressure.
PIOMBATURA CODE aumentano solo la pressione
916005 di pilotaggio.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070606.13.00 8:1 100-350 bar 300 bar 90 bar/turn 140 l/min 400 bar 3/4"G 9.4 kg
Pag. 07.07.01

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 140
Dual overcenter valve in line with regenerative circuit "140 series"

H4 S3 S4
H3
C2 C1
2

L1

L4
4 2

D (n.2)
1 3 3
4 C1
C1
V1 V1
V2 V1

L8
C2

L2

L5
C2
CURVE CARATTERISTICHE V2
p (bar)

L7
PERFORMANCE CURVES
V2
L3
40

L6
PRESSIONE / PRESSURE -

32
V2
C2

L1

24 C2 1
C2
C1

H1 H2 S2
16 V2
C1 H S S1
8 V1

0 8 16 24 32 40
PORTATA / FLOW - Q(l/min)

Corpo in alluminio / Aluminium body


130 ~31 49 28.5 3.9 82 8 56 32 50 4.9 30 15 21 60 22 8 4.5 15 6.5
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 S4 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare valves with the regenerative
lolio scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916001

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 100-350 bar 210 bar
A070360.02.00 4.1:1 140 bar/turn 40 l/min 450 bar 3/8"G 1.3 kg
2 100-430 bar 430 bar
Pag. 07.07.02

Valvola di blocco bilanciata doppia con circuito rigenerativo serie 190


Dual overcenter valve with regenerative circuit "190 series"

S L2 L L1
S2 S1 L3 L4

C2 C1

B
C1 C2

H
D (n.2)

H1

H4
V2 V1

H3
V1 V2
L5 L6
S3

H2
L7 L8

CURVE CARATTERISTICHE F2 F1 F
p (bar)

PERFORMANCE CURVES
30
S5

S7
25 C2
PRESSIONE / PRESSURE -

S4

20 C1 C2
V2

S6
15
C1 A
10 V1 B
V2
5 C2

0 10 20 30 40 50 60
PORTATA / FLOW - Q(l/min)

Corpo in alluminio / Aluminium body


134 ~41 ~43 59 51 45 8 72.5 20.5 60 26 16.5 39 22.5 21 22.5 21 90 48 8 31.5 49 51 50.5 8.5 8.5
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 H4 F F1 F2 D

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder matches
alla sola pressione agente only the pressure operating
sulla sezione dello stelo. on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916001

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A 4.2:1 100-350 bar 200 bar 135 bar/turn V1,V2,C1,C2 1/2"G
B070460.01.00 60 l/min 360 bar 2.4 kg
B 4.2:1 100-360 bar 360 bar 110 bar/turn M 1/4"G
Pag. 07.07.03

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 210
Dual overcenter valve in line with regenerative circuit "210 series"

L3 L4 L5
S
S2
B1 A1
S1

F
2
5

A
4

L
6

L1
1

S3
3

L2
B A
D(n3) 4 (26VDC)
F

H4 6 2
CURVE CARATTERISTICHE
p (bar)

F1
PERFORMANCE CURVES H5

25
B1
PRESSIONE / PRESSURE -

20 1
15 B1

F2
HEX8
H2

A1

H
10
B B1
5 B A1
B1

F3
0 20 40 60 80 100
H3

H1 5 3
F5

PORTATA / FLOW - Q (l/min) HEX13


F4
HEX24

Corpo in alluminio / Aluminium body


B070660.02.00 98 55 16 43.5 150 39.5 125 38 34.5 50 98 8 78 12 82 63.5 ~5 ~13 39 38 62 5.5 M8
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 H5 F F1 F2 F3 F4 F5 D

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1-2 100-380 bar 350 bar 92 bar/turn
B070660.02.00 4:1 100 l/min 350 bar 3/4"G 4.8 kg
3 60-300 bar 240 bar 65 bar/turn
Pag. 07.07.04

Valvola di blocco bilanciata doppia angiabile con circuito rigenerativo serie 165
Flangeable dual overcenter valve with regenerative circuit "165 series"

F1

C1 C2 V1
V2
Valve 1

F3

H3
H4
F4
Valve 2 T
F2
F HEX24

D (n4)

T V1 V2

S
S1
CURVE CARATTERISTICHE
PERFORMANCE CURVES O-RING
PRESSIONE / PRESSURE - p (bar)

D1 (n4)

S2
25
Valve 2
20

H2
V2 C1 C2
=

15
H1

C2
=

10 C2
H

5 V2

0
10 20 30 40 50 = = Valve 1
L5
PORTATA / FLOW - Q (l/min)
L4
L3
L2 L L1
Corpo in alluminio / Aluminium body
B070390.01.00 130 51 11.5 108 32 34 69 54 9 85 34 25 58 60 108 110 47 69 25 8.5 13.5 3093 23.47x2.62
COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 F F1 F2 F3 F4 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
1 4.25:1 100-350 bar 220 bar 135 bar/turn V1,V2,C2, T 3/8"G
B070390.01.00 45 l/min 350 bar 2.3 kg
2 7:1 100-320 bar 300 bar - C1 15
Pag. 07.07.05

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 275
Dual overcenter valve in line with regenerative circuit "275 series"

L2 L L1
C2 C1 EV3 VU7

Vu4 Ovc2

Vu5
Ev3
Ev2 Ovc1 Str

S
Vu7
0.5
1.2 OVC2

V2 V1
VU4
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE C2 O-RING


PERFORMANCE CURVES
OVC1
25
20
15 C2 V2
10
V2 C2
5
0
25 50 75 100 125 150
D (n4) EV2
PORTATA / FLOW - Q (l/min)
S3

C1
S5
S6

V2
S2

S4

S7
S1

V1 C2

Str

H2 L5 H3
H1 L4
H L3
Corpo in alluminio / Aluminium body
B070660.07.00 174 ~62 ~59 82 22.2 11.1 148 127 77 14 47.6 23.8 34 82 99 42 30 21.5 10.5 OR 24.99x3.53
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 D O-RING

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare valves with the regenerative
lolio scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Code Setting Increase Pressure
1 100-350 bar 350 bar 108 bar/turn V1, V2, C1 3/4"G
B070660.07.00 4:1 150 l/min 350 bar 9 kg
2 100-350 bar 350 bar 70 bar/turn C2 22
Pag. 07.07.06

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 210
Dual overcenter valve in line with regenerative circuit "210 series"

H6

H1
C2 C1

H
valve 1

H6
valve 2
L6 L5 L4
M
valve 2 valve 1
F1 F

S1
V2 V1

S
CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

L
HEX27
25

20

15 C2

H3
C1
H5

10
C2

H2
5 V2 V2
C2
0

H4
D (n2)
20 40 60 80 100
L1 L2
PORTATA / FLOW - Q (l/min)
L3
Corpo in alluminio / Aluminium body
B070460.05.00 148 51.5 30.5 129 91 38 61.2 79 10 79 20 25 33 20 22 13 100 10 M10
COD. L L1 L2 L3 L4 L5 L6 S S1 H H1 H2 H3 H4 H5 H6 F F1 D

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione P Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Setting Increase Flow Pressure
1 300-500 bar 420 bar 125 bar/turn V1, V2, C1, C2 1/2"G
B070460.05.00 4:1 100 l/min 350 bar 3.2 kg
2 300-500 bar 420 bar 125 bar/turn M 1/4"G
Pag. 07.08.01

Valvola di blocco bilanciata doppia angiabile serie 210


Flangeable dual overcenter valve for open centre "210 series"

C2 C1 L1 L L1
L2 L3

V2 V1

C2

H
H1
H3
C1
V2 V1
p (bar)

H2
CURVE CARATTERISTICHE
PERFORMANCE CURVES H4 L6
PRESSIONE / PRESSURE -

25 L5 L4
20
D1 (n.2)
15 D (n.4)
C1 V1 HEX24 O-RING
10
5 V1 C1

0 25 50 75 100 125 150

=
S
PORTATA / FLOW - Q (l/min)

=
Corpo in acciaio / Steel body
165 ~42 87 39 65 35 17.5 39.5 100 29 31.5 72 10 10.5 13 OR 123 17.86x2.62
L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 H4 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco when the spool valve
del carico con distributore is in neutral position
in neutro o a pompa ferma or the pump is not running
(tralamento max. 5 gocce/min) (max. Leakage 5 drops/min).
e permette di scaricare un picco Peaks of pressure can be
di pressione se la spola relieved only with open centre
del distributore a centro spool valves. The valve
aperto. Tarare ad almeno must be set at 1.3 times
1,3 volte la pressione massima the max. load induced pressure.
indotta dal carico. Eventuali Back pressure downstream
contropressioni sullo scarico the valve increases the setting
aumentano la pressione and the requested pilot
di taratura e di pilotaggio pressure. The one-way
richiesta per pilotare la valvola. restrictors on the pilot
Sulla linea di pilotaggio una lines allow to dump
CODICE ORDINAZIONE SEALING ORDERING strozzatura unidirezionale the valve piloting.
PIOMBATURA CODE regolabile permette di smorzare
916013 il pilotaggio della valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070681.01.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3/4"G 4.7 kg
A070681.02.00 8:1 150-350 bar 350 bar 82 bar/turn 150 l/min 500 bar 3/4"G 4.7 kg
Pag. 07.09.01

Valvola di blocco bilanciata doppia angiabile per serie 210 CC


Flangeable dual overcenter valve for closed centre "210 CC series"

C2 C1 L1 L L1

SFIATO/ L2 L3
AIR BLEED

V2 V1
C2
V2 V1

H
H1
C1

H3
.4)
D1(n
p (bar)

H4
CURVE CARATTERISTICHE
PERFORMANCE CURVES = = SFIATO/

H2
PRESSIONE / PRESSURE -

25 L4 AIR BLEED
20 L5
15 V1 O-RING D (n.2)
C1 C1
10
5 V1
=

0 25 50 75 100 125 150


S

PORTATA / FLOW - Q (l/min)


=

Corpo in acciaio / Steel body


165 46 87 39 35 82,5 39.5 100 72 10 60.5 31.5 13 10.5 OR 123 17.86x2.62
L L1 L2 L3 L4 L5 S H H1 H2 H3 H4 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow


libero da V1>C1 o V2>C2 from V1>C1 or V2>C2
e il controllo nel verso opposto and the control in the opposite
tramite lazione della pressione direction. The load is locked
di pilotaggio. Assicura il blocco del when the spool valve is
carico con distributore in neutro in neutral position or the pump
o a pompa ferma (tralamento is not running (max. leakage
max. 5 gocce/min) e permette 5 drops/min). Peaks of pressure
di scaricare i picchi di pressione se can be relieved only if the spool
la spola del distributore munita valve is equipped with shock
di valvola antishock, tarata valves, to be set at least
ad almeno 30 bar al di sotto 30 bar below the valve setting.
della taratura della valvola. The valve must be set
Tarare ad almeno 1,3 volte at 1.3 times the max. load
la pressione massima indotta dal induced pressure.
carico. Eventuali contropressioni Back pressure downstream
sullo scarico aumentano solo the valve increases only
la pressione di pilotaggio. the required pilot pressure.
La valvola ha 2 sati allaria. The valve ts 2 air bleeds.
Sulla linea di pilotaggio The one-way restrictors
CODICE ORDINAZIONE SEALING ORDERING una strozzatura unidirezionale on the pilot lines allow
PIOMBATURA CODE regolabile permette di smorzare o dump the valve piloting.
916013 il pilotaggio della valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070686.01.00 4:1 100-350 bar 350 bar 108 bar/turn 150 l/min 500 bar 3/4"G 4.7 kg
A070686.02.00 8:1 150-350 bar 350 bar 82 bar/turn 150 l/min 500 bar 3/4"G 4.7 kg
Pag. 07.10.01

Valvola di blocco bilanciata doppia con dierenziale zero serie 190


Dual overcenter valve with zero dierential "190 series"

L1 L L2
L3 L4 L5 L6

B1 A1

S3
M

2 4

S2
3

S
S1
1

T B A D (n.2)
L7 L8
PRESSIONE / PRESSURE - p (bar)

F F1

H4
CURVE CARATTERISTICHE
PERFORMANCE CURVES
25 B1 A1

H1
3
20 4
T

15
H6

H2
H

1
B1

10
A 2
H5

5 A1

H3
T B A M
0 15 30 45 60 75 90
F2 F3 F4
PORTATA / FLOW - Q (l/min)
Corpo in alluminio / Aluminium body
182 ~47 ~51 42 49.5 39.5 30 90 46 70 52.5 35 17.5 90 27 33 19 10 38 19 91 66 42 89 30 8.5
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 F F1 F2 F3 F4 D

DESCRIZIONE DESCRIPTION

Il controllo della discesa del carico The control on the bottom side is
sul lato fondello avviene per il solo due only to the eect of the
eetto della pressione di piloting pressure applied to the
pilotaggio applicata alla valvola A A valve, that is not aected by
che non risente della pressione the pressure induced by the load.
indotta dal carico. Eventuali picchi Pressure peaks are relieved by
di pressione sul fondello sono the valve directly linked to the
scaricati dalla valvola, che deve drain. The sequence valve 4
essere collegata a scarico allows to give pressure to the
direttamente. La valvola di rod side only when the pressure
sequenza 4 permette di dare passes the setting value of the
pressione al lato stelo solo quando valve itself, that is when there's a
la pressione supera il valore di force, so that not to interfere
taratura della valvola stessa, cioe with the manometer group. On
quando occorre una forza, in modo the anular area operates pipe T
da non interferire con il blocco pressure. Suitable for use with
manometro. Durante la discesa proportional distributors.
CODICE ORDINAZIONE SEALING ORDERING sulll'area anulare agisce la
PIOMBATURA CODE pressione del ramo T . Idonea per
916001 - 916003 - 916005 uso con distribitori proporzionali.

Codice Rapporto di Campo di Taratura Incremento Portata Dimensione Porte Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Port Size Weight
Setting Increase
- 1 10-45 Bar 30 Bar 8 Bar/turn
A1-a 90 L/min A, B, T,
A1, B1 1/2"g
11:1 2 200-400 Bar 350 Bar 115 Bar/turn
B070461.07.00 3.6 Kg
- 3 200-400 Bar 380 Bar 110 Bar/turn
B1-t 60 L/min M 1/4"g
- 4 10-55 Bar 35 Bar 8 Bar/turn
Pag. 07.10.02

Valvola di blocco bilanciata doppia con dierenziale zero serie 210


Dual overcenter valve with zero dierential "210 series"

C1 C2 T
M

F
3 2 C1
1 V1

T V1 V2 C2

L
M
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
25
PRESSIONE / PRESSURE -

20
C2

15 C1 V2
10 V1
V2

5
0
15 30 45 60 75 90 105 120 135

PORTATA / FLOW - Q (l/min)


S
Corpo in alluminio / Aluminium Body

COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 S5 H H1 H2 H3 F F1 F2 F3 D D1 O-RING

DESCRIZIONE DESCRIPTION

Il controllo della discesa del carico The control on the bottom side
sul lato fondello avviene per il solo is due only to the eect of the
eetto della pressione di pilotaggio piloting pressure applied to the
applicata alla valvola 1 che non 1 valve, that is not aected
risente della pressione indotta dal by the pressure induced by the load.
carico. Eventuali picchi di pressione Pressure peaks are relieved
sul fondello sono scaricati dalla by the valve directly linked
valvola, che deve essere collegata to the drain. The sequence valve
a scarico direttamente. La valvola 4 allows to give pressure to the rod
di sequenza 4 permette di dare side only when the pressure passes
pressione al lato stelo solo quando la the setting value of the valve itself,
pressione supera il valore di taratura that is when there's a force, so that
della valvola stessa in modo da non not to interfere with themanometer
interferire con il blocco manometro. group. On the anular area operates
CODICE ORDINAZIONE SEALING ORDERING Durante la discesa sulll'area anulare pipe T pressure. Suitable for use
PIOMBATURA CODE agisce la pressione del ramo T. Idonea with proportional distributors.
916003 - 916005 - 916013 per uso con distribitori proporzionali.

Codice Rapporto di Campo di Taratura Portata Massima Dimensione delle Peso


Ordinazione Pilotaggio Taratura Standard Porte
Ordering Pilot Ratio Campo di Standard Max Flow Port Size Weight
Code Taratura Setting
1 - - 30 bar V1,V2,T 1/2"G
C2-V2 150 l/min
2 - 200-400 bar 370 bar M 1/4"G
B070481.34.00 3 kg
3 11:1 200-400 bar 350 bar C1 9
C1-T 60 l/min
4 - - 50 bar C2 11.5
Pag. 07.11.00

Valvola di blocco bilanciata doppia in linea serie 140


Dual overcenter valve in line "140 series"

F1 F

S2

S1
V1 V2
C2 C1

S
=
H
F3 F2
H2 H1
D (n.2)
H8
V2 V1 H3 H4

F4
L2
C1 C2

L5
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

L1

L4
25
20 V1
L
D1 (n.4)
15 C1

10
C1
V1
5

0 OVC 2
5 10 15 20 25 30 OVC 1
L3

PORTATA / FLOW - Q (l/min)


H7 H6 HEX22
H5
Corpo in acciaio / Steel body

A070361.55.00 90 40 8 29.5 68 30 40 16 10 74 48 13 25.5 22.5 81.6 55 9.5 38.5 28 23 63 5.5 10 8.5 M8


COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 H5 H6 H7 H8 F F1 F2 F3 F4 D D1

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da V1>C1 o V2>C2 e il controllo V1>C1 or V2>C2 and the control
nel verso opposto tramite lazione in the opposite direction.
della pressione di pilotaggio. Assicura The load is locked when
il blocco del carico con distributore in the spool valve is in neutral
neutro o a pompa ferma (tralamento position or the pump is not running
max. 5 gocce/min) e permette (max. Leakage 5 drops/min).
di scaricare un picco di pressione se Peaks of pressure can be relieved
la spola del distributore a centro only with open centre spool valves.
aperto. Tarare ad almeno 1,3 volte The valve must be set at 1.3 times
la pressione massima indotta dal the max. load induced pressure.
carico. Eventuali contropressioni Back pressure downstream
sullo scarico aumentano la pressione the valve increases the setting
di taratura e di pilotaggio richiesta and the requested pilot pressure.
per pilotare la valvola. Sulla linea The one-way restrictors on the pilot
di pilotaggio una strozzatura lines allow to dump the valve piloting.
unidirezionale regolabile permette
di smorzare il pilotaggio della valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte
Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A070361.55.00 4.1:1 1-2 200-400 bar 450 bar 192 bar/turn 30 l/min 500 bar 3/8"G 2 kg
Pag. 07.11.01

Valvola di blocco bilanciata doppia serie 165


Dual overcenter valve "165 series"

L L1
L2

F2 V2

V2 F2

F1 V1

H2
H3

H
V1 F1
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE

H1
PERFORMANCE CURVES
25
20 H4 D (n.2) HEX30
15 F1 V1
10 V1 F1

S1
5
S

0 20 40 60 80
PORTATA / FLOW - Q (l/min)
S2

Corpo in acciaio / Steel body


96.5 28.5 30 40 17.5 3,8 80 22 36 68 6 M8
L L1 L2 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola permette il usso The valve allows free ow from


libero da V1>C1 o V2>C2 e il V1>C1 or V2>C2 and the control
controllo nel verso opposto in the opposite direction. The
tramite lazione della pressione load is locked when the spool
di pilotaggio. Assicura il blocco valve is in neutral position or
del carico con distributore the pump is not running (max
in neutro o a pompa ferma leakage 5 drops/min). Peaks of
(tralamento max. 5 gocce/min) pressure can be relieved only
e permette di scaricare i picchi di with open centre spool valves.
pressione se la spola del The valve must be set at 1,3
distributore a centro aperto. times the max. load induced
Tarare ad almeno 1,3 volte la pressure. Back pressure
pressione massima indotta dal downstream the valve increases
carico. Eventuali contropressioni the setting and the requested
sullo scarico aumentano la pilot pressure.
CODICE ORDINAZIONE SEALING ORDERING pressione di taratura e di
PIOMBATURA CODE pilotaggio richiesta per pilotare
916001 la valvola.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A070461.22.00 4.2:1 100-350 Bar 350 Bar 195 Bar/turn 80 L/min 400 Bar 1/2"g 2.3 Kg
Pag. 07.12.01

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

H
C3 H1 HEX5 S S1
HEX17

1
H2 4
V2 C2

L1
H3
1

L5
4
3
V1 C1
2 V2 V2
C1

L4
L2
p (bar)

L3
L
CURVE CARATTERISTICHE C3
PERFORMANCE CURVES
25
C2
PRESSIONE / PRESSURE -

20 V1 V1
15
V2
10
C2 C2 2

L5
5 V2
L1

HEX13
0 8 16 24 32 40 3
HEX4
PORTATA / FLOW - Q (l/min)
H5 H4 S2 S3

Corpo in alluminio / Aluminium body


80 ~51.4 40 36 22 ~43.5 78 12.5 32.5 31 80 18 49 40 52 14
L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 H5

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable


doppia con angiatura per overcenter valve for
motori idraulici DINAMICOIL. DINAMICOIL machines.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Range Standard


Setting
Pressure
Increase
Max
Flow
Max
Pressure Port Size Weight
1-2 60-220 bar 190 bar 135 bar/turn V1, V2, C1, C2 3/8"G
B070381.22.00 4.2:1 40 l/min 350 bar 1.95 kg
2-3 40-150 bar 90 bar 45 bar/turn C3 1/4"G
Pag. 07.12.08

Valvola di blocco bilanciata doppia Flangiabile per motori idraulici serie


Flangeable dual overcenter valve for hydraulic motors "165 series"

L1 L L1

H6
C3 C3

H7

H8
2 1

H5

H9
V2 1 C2
4

H
3 4
3

H4
V1 C1
2

H3

H1
C2 C1

HEX5
L2 L3
H2
HEX17
CURVE CARATTERISTICHE L7 L6
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25 V2

S2
20
15 V1 C1
C2

S
S1
S3
S5

C1 C1
10 V1
5
S6

V1 HEX4

0 10 20 30 40 50 60
HEX13
S4

L5 L4
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


80 ~52 36 22 65 7.5 41 19.5 80 36 22 65 7,5 26 27 101.5 21 12.5 23.5 31.5 49 4.5 14 31 64.75
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 S4 S5 S6 H H1 H2 H3 H4 H5 H6 H7 H8 H9

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual overcenter valve with


doppia con valvola di dual angeable relief valve
massima doppia incrociata cross-line for danfoss motors
angiata con bulloni per OMR, OMP.
motori danfoss OMR, OMP.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Range Standard Pressure Max
Max Flow Pressure Port Size Weight
Code Setting Increase
1-2 60-220 bar 200 bar 135 bar/turn V1, V2, C1, C2 1/2"G
B070481.33.00 4.2:1 60 l/min 350 bar 2.4 Kg
3-4 100-350 bar 130 bar 110 bar/turn C3 1/4"G
Pag. 07.13.01

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S1 S H5 H6
C1 C2 S2 HEX4
H3 H4
O-RING S3 HEX13

C3 D (n.2)

V1 V2
C1 V2
C3
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
L6

L3

L1
PERFORMANCE CURVES

L5
25 C2 V1
20

L4
C1
L7

15 V1
10 C1 V1

L2
5

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)
H1 H2
H

Corpo in alluminio / Aluminium body


80 67 6.5 40 20 40 44 18 68 10 31 14 80 27 26 31.5 17 25 30 M8 OR 3100 25.07x2.62
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 H H1 H2 H3 H4 H5 H6 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for DINAMICOIL machines.
motori idraulici DINAMICOIL.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2 1/2"g
B070481.22.00 4.2:1 60-220 Bar 40 Bar 45 Bar/turn 60 L/min 350 Bar 1.5 Kg
C3 1/4"g
Pag. 07.13.02

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S1 S H2
S2 H3 H4 HEX4
C1 C2
HEX13

L6
C1
C3

V1 V2 V2
C3
L5

L2
p (bar)

L
CURVE CARATTERISTICHE C2
PERFORMANCE CURVES V1

L1
25

L3
PRESSIONE / PRESSURE -

L4

20
15 V1 C1
D (n.4)

10 C1 V1

L6
5

0 10 20 30 40 50 60 H1
PORTATA / FLOW - Q (l/min) H

Corpo in alluminio / Aluminium body


80 40 41 19.5 18 44 ~41 70 15 14 80 27 53 31.5 17 M8
L L1 L2 L3 L4 L5 L6 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for DINAMICOIL machines.
motori idraulici DINAMICOIL.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1, C2 1/2"G
B070481.25.00 4.2:1 60-220 bar 190 bar 135 bar/turn 60 l/min 350 bar 1.5 kg
C3 1/4"G
Pag. 07.13.03

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S2 S3 H
C3 S4 S5 H1 H2
S6

V2 1 C2

L1
)
4 3 2 n.2
D(

O-ring 3100 25.07x2.62


L3
3
V1 C1
2

L8

L6
L4
C2 V1
C3
L2

L7

L5
L
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE C1
PERFORMANCE CURVES V2
25
20
15 V1 C1
1 4
10 C1 V1
L1

5
HEX4
0 10 20 30 40 50 60 HEX17
HEX13 H3 H4
S1 S
PORTATA / FLOW - Q (l/min) HEX5
H5 H6

Corpo in alluminio / Aluminium body


80 ~51 67 6.5 40 40 20 44 18 81.5 9.5 30 49 16 32.5 14 80 27 26 25 30 31,5 17 M8
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 S4 S5 S6 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual overcenter valve with dual


doppia con valvola di massima angeable relief valve cross-line
doppia incrociata angiata for DINAMICOIL machines.
con bulloni per motori idraulici
DINAMICOIL.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Pilot Ratio Pressure Range Standard


Ordering Pressure Max Max Port Size Weight
Code Setting Increase Flow Pressure
4.2:1 1-2 60-220 Bar 200 Bar 135 Bar/turn V1, V2/c1, C2 1/2"g/19
B070481.26.00 60 L/min 350 Bar 1.8 Kg
- 3-4 100-350 Bar 130 Bar 110 Bar/turn C3 1/4"g
Pag. 07.13.04

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S
H1 H
S1 H2
C1 C2 S2 S3

L6
H5
C3
C1

D (n.2)
V1 V2
V2
C3

L3
L5

L
p (bar)

V1
CURVE CARATTERISTICHE

L1
PERFORMANCE CURVES

L2
25

L4
C2
PRESSIONE / PRESSURE -

20
15 V1 C1
10 C1 V1
H3

L6
5

0 10 20 30 40 50 60 HEX13

PORTATA / FLOW - Q (l/min) HEX4 S4 H4

Corpo in alluminio / Aluminium body


80 40 24 32 19.5 41 ~42 80 53 22 29 27 70 15 49 14 31 12.5 28.7
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Danfoss OMS/OMSW OMSS.


doppia con angiatura Dual angeable overcenter
per motori danfoss valve for danfoss motors
OMS/OMSW OMSS. OMS/OMSW OMSS.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1, C2 1/2"G
B070481.27.00 4.2:1 60-220 bar 190 bar 135 bar/turn 60 l/min 350 bar 1.5 kg
C3 1/4"G
Pag. 07.13.05

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

H
S1 S
H1
S2
H2 H3
C1 C2

L2
S3

C3 C1

D (n.2)
V1 V2 V2
C3

L4
L6

L
p (bar)

CURVE CARATTERISTICHE C3 V1
PERFORMANCE CURVES

L1
25
PRESSIONE / PRESSURE -

L3
L5
20 C2
15 V1 C1
10 C1 V1
5 S4

L2
0 10 20 30 40 50 60 HEX13
PORTATA / FLOW - Q (l/min)
HEX4 H4 S5

Corpo in alluminio / Aluminium body


80 40 ~42 22 36 19.5 41 70 15 49 12.5 14 31 80 53 36 22 27 28.7
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 S5 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for danfoss motors OMR
motori danfoss OMR, OMP e OMP and white series HS, HP.
white series HS e HR.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2, C1, C2 1/2"G
B070481.28.00 4.2:1 60-220 bar 190 bar 135 bar/turn 60 l/min 350 bar 1.5 kg
C3 1/4"G
Pag. 07.13.06

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

L1 L L1

H3
C3 = =

C3

H4

H2
V2 1 C2 2 1

H5

H1
4
3

H
3 4
V1 C1

H6
2

HEX5

H7
HEX17

C2 C1
H8
p (bar)

CURVE CARATTERISTICHE L2 L3

H9
PERFORMANCE CURVES L6
L5
25 L4
L7
PRESSIONE / PRESSURE -

20
15 V1 C1 V2
HEX13
10 C1 V1 HEX4
5
S1

S6
S3
S

0 10 20 30 40 50 60
S2

S5
S4
PORTATA / FLOW - Q (l/min) V1

Corpo in alluminio / Aluminium body


80 ~52 32 24 41 19.5 65 7.5 80 65 7.5 22 29 27 26 101.5 64.75 31 4.5 14 49 31.5 21 2.5 12.5
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 S4 S5 S6 H H1 H2 H3 H4 H5 H6 H7 H8 H9

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual overcenter valve


doppia con valvola di massima with dual angeable relief valve
doppia incrociata angiata cross-line for danfoss motors
con bulloni per motori danfoss OMS/OMSW OMSS.
OMS/OMSW OMSS.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max
Ordering Pilot Ratio Pressure Range Standard Pressure Max
Max Flow Pressure Port Size Weight
Code Setting Increase
4.2:1 1-2 60-220 bar 200 bar 135 bar/turn V1, V2, C1, C2 1/2"G
B070481.30.00 60 l/min 350 bar 2.4 kg
- 3-4 100-350 bar 130 bar 110 bar/turn C3 1/4"G
Pag. 07.13.07

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

L1 L L1
= =

H3
C3
C3

H2
2 1

H4
H5
1

H1
V2 C2
4

H
3 3 4

H6
V1 C1
2
HEX5

H8
H7
HEX17

C2 C1
L2 L3
H9
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

L6
PERFORMANCE CURVES L5
25 L4
L7
20
V2
V1

S6
15 HEX13
C1
HEX4
10 C1 V1
S1
S

S3
S7
0 10 20 30 40 50 60

S5
S4
V1
PORTATA / FLOW - Q (l/min)
S2

Corpo in alluminio / Aluminium body


80 ~52 20 40 41 19.5 65 7.5 80 72.5 7.5 53 3 27 8 47.8 107.5 64.75 31 4.5 14 49 31.5 29.5 27 12.5
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 H4 H5 H6 H7 H8 H9

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual overcenter valve with


doppia con valvola di dual angeable relief valve
massima doppia incrociata cross-line for danfoss motors
angiata con bulloni per OMR, OMP.
motori danfoss OMR, OMP.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Range Standard Pressure Max
Max Flow Pressure Port Size Weight
Code Setting Increase
1-2 60-220 bar 200 bar 135 bar/turn V1, V2, C1, C2 1/2"G
B070481.32.00 4.2:1 60 l/min 350 bar 2.4 Kg
3-4 100-350 bar 130 bar 110 bar/turn C3 1/4"G
Pag. 07.13.09

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S1 S L
S2 L2 L1

C1 C2

H1
C1
V2
C3

V1 V2

H3

H5
C2

H
C3
p (bar)

H2
CURVE CARATTERISTICHE

H4

H6
PERFORMANCE CURVES V1
25
PRESSIONE / PRESSURE -

20
V1
C1

H1
15
C1
10 V1
5 HEX13
S3
0 10 20 30 40 50 60 HEX4 S4 L3 L4
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


80 47.8 8 27 26 76 15 49 14 31 80 ~42 40 40 20.2 41 19.5
L L1 L2 L3 L4 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 H6

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura valve for SAMHYDRAULIK
per motori SAMHYDRAULIK MB1010 motors.
MB1010.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1, C2 1/2"G
B070481.35.00 4.2:1 60-220 bar 130 bar 135 bar/turn 60 l/min 350 bar 1.6 kg
C3 1/4"G
Pag. 07.13.10

Valvola di blocco bilanciata doppia serie 165 angiabile per motori idraulici
Dual overcenter valve 165 series angeable for hydraulic motors

S1 S L
L1
S2
L2 L3
C1 C2

H1
D (n.2)
C3 V2

V1 V2
C1 C3

H3

H6

H8
H
C2
p (bar)

H4

CURVE CARATTERISTICHE

H5

H7
PERFORMANCE CURVES

H2
25 V1
PRESSIONE / PRESSURE -

20
15 V1 C1 HEX13

H1
10 C1 V1
HEX4
S3
5

0 10 20 30 40 50 60 L4 L5
S4
PORTATA / FLOW - Q (l/min)
L6

Corpo in alluminio / Aluminium body


80 53 29 22 24 32 27 68 11.5 49 14 31 80 ~42 19.5 41 40 19 42 24 32 M10
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 H6 H7 H8 D

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura valve for danfoss motors OMS.
per motori danfoss OMS.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1, C2 1/2"G
B070481.38.00 4.2:1 60-220 bar 190 bar 135 bar/turn 60 l/min 350 bar 1.5 kg
C3 1/4"G
Pag. 07.13.11

Valvola di blocco bilanciata doppia per centro aperto


Dual overcenter valve for open centre

L3 L4 L3

C1

H4

H2
H5
C1

H5
H3

H1

H
H5
H5
H4

H2
L1 L L1
D1 (n.4) L2

S3
V1

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

S
S1
PERFORMANCE CURVES
S2

25
D (n.4)
20 HEX5
L5 L6 L5
15 V1 C1
HEX13
10 C 1 V 1 V1
H4

0 10 20 30 40 50 60
H3

PORTATA / FLOW - Q (l/min)


H4

Corpo in acciaio / Steel body


A070481.41.00 85 ~42 41 24.5 36 19 47 54 38 22 9.5 88 32 28 36 26 20 8.25 13.5
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 D D1

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for DANFOSS OMR and
motori idraulici DANFOSS OMR OMP machines.
e OMP.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE
916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2 1/2"G
A070481.41.00 4.2:1 60-220 Bar 160 Bar 135 Bar/turn 60 L/min 350 Bar 2.8 kg
C3 1/4"G
Pag. 07.13.12

Valvola di bilanciamento doppio eetto angiata con cartuccia serie SM


Flangeable single overcenter valve with cartridge "SM series"

D (n2)

H4
H1
C1 C2

H5
C2

H2
H

H6
C1

L4 HEX4

H3
L3 L2 L1 HEX13
V1 F V2 L

CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

S
25 C1 C2
PRESSIONE / PRESSURE -

20
V1 O-RING
15
C1 C1 V1
10
V1 F
5

G1
0 V2
20 40 60 80
G

PORTATA / FLOW - Q (l/min)

G2
G3
G4

Corpo in alluminio / Aluminium body


B070481.31.00 110 5 32 17 5 53 78 17 27.5 3.5 5 22 5 48 38 20 34 78 10.5 OR 130 22.22x2.62
COD. L L1 L2 L3 L4 S H H1 H2 H3 H4 H5 H6 G G1 G2 G3 G4 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for DANFOSS OMS
motori idraulici DANFOSS OMS. machines. The valve allows:
Permette il usso libero free ow from V1 to C1
da V1 verso C1 e da V2 and from V2 to C2.
verso C2.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 1/2"G
B070481.31.00 4.25:1 80-350 bar 210 bar 108 bar/turn 80 l/min 350 bar 1.52 kg
F M10x1
Pag. 07.13.13

Valvola di bilanciamento doppio eetto angiata con cartuccia serie SM


Flangeable single overcenter valve with cartridge "SM series"

D (n 4)

H4
C1 C2

H1
C2

H2
C1

H3 H3

H4
HEX4
L2 L1
L HEX13
V1 F V2
S2

S1
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

S
20 C1 C2
PRESSIONE / PRESSURE -

16
O-RING
12 V1
C1 C1 V1
8
4 V1
F

G1
V2
0 15 30 45 60
G

G2
PORTATA / FLOW - Q (l/min)
G3
G4

Corpo in alluminio/Aluminium body


B070381.26.00 110 36 16.5 48 9 14.5 88 26 36 20 20 36.5 40 24 38 78 8.5 OR 130 22.22x2.62
COD. L L1 L2 S S1 S2 H H1 H2 H3 H4 G G1 G2 G3 G4 D O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for DANFOSS OMP
motori idraulici DANFOSS OMP. machines. The valve allows:
Permette il usso libero da V1 free ow from V1
verso C1 e da V2 verso C2. to C1 and from V2 to C2.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1-V2 3/8"G
B070381.26.00 4.25:1 80-350 bar 210 bar 108 bar/turn 55 l/min 350 bar 1.55 kg
F M10x1
Pag. 07.13.14

Valvola di blocco doppia serie 165 angiabile per motori idraulici


Dual overcenter valve "165 series", angeable for hydraulic motors

L1
L
L5
= =
L6

S1
C1 C2 M2
M1 M2
C2

=
C3 V1

=
S2
S3

S
=
V2
= C1
V1 C3 V2 = = M1
L6

S1
L4
L2 L3
CURVE CARATTERISTICHE HEX13
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
D (n2) O-RING HEX4
25
20 M2
15 V1 C1
H

V1

H2
10 C1
H1

5 V2 C3 V1
D1 (n2)
0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


B070481.50.00 151 242 max 19.5 112 42 32 52 59 5 32 22 39.5 10 14 10.5 16.5 OR 3093 23.47x2.62
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per motori valve for danfoss motors
danfoss OMS/OMSW OMSS. OMS/OMSW OMSS.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Dimensione Porte
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
V1, V2 1/2"G
B070481.50.00 4.2:1 100-350 bar 350 bar 135 bar/turn 60 l/min 350 bar C3, M1, M2 1/4"G 1.1 kg
C1, C2 10
Pag. 07.13.15

Valvola di blocco bilanciata doppia angiabile, serie 165


Flangeable dual overcenter valve "165 series"

L1 L L1
L2
= =

S1
C1 C2
M1 M2 M2
V2 C3 V1

=
= =
C2

S3
S2
C1

=
V1 C3 V2
M1
= =
S1

L5

CURVE CARATTERISTICHE L4 L3
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25
20
O-RING
15 V1 C1 D(n2)
V1

H2
10 C1
5 M2
0
H

10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)
V2 C3 V1
H1

D1

Corpo in alluminio / Aluminium body

B070481.43.00 151 13 32 112 19.5 42 59 5 22 32 39.5 10 14 10.5 16.5 OR 3093 23.47x2.62


COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola permette il usso libero The valve allows free ow from


da A>C1 o B>C2 e il controllo A>C1 or B>C2 and the control
nel verso opposto tramite lazione in the opposite direction.
della pressione di pilotaggio. The load is locked when the spool
Assicura il blocco del carico con valve is in neutral position or the
distributore in neutro o a pompa pump is not running (max leakage
ferma (tralamento max. 5 5 drops/min ). Peaks of pressure
gocce/min) e permette di scaricare can be relieved only with open
i picchi di pressione se la spola del centre spool valves. The valve
distributore a centro aperto. must be set at 1,3 times the max.
Tarare ad almeno 1,3 volte load induced pressure.
la pressione massima indotta Back pressure downstream
dal carico. Eventuali contropressioni the valve increases the setting
sullo scarico aumentano la and the requested pilot pressure.
pressione di taratura e di pilotaggio
richiesta per pilotare la valvola.

Codice Ordinazione Rapporto di Taratura Portata Pressione Dimensione Porte Peso


Pilotaggio Standard Massima Max
Ordering Code Pilot Ratio Standard Max Flow Max Port Size Weight
Setting Pressure
V1-V2 1/2"G
B070481.43.00 11:1 200 bar 60 l/min 210 bar 1.1 kg
C3-M1-M2 1/4"G
Pag. 07.15.01

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 210
Dual overcenter valve in line with regenerative circuit "210 series"

L2
HEX24 L3 L4

H2
H1
C2 C1

V2 V1

H5
D (n.2)

H4
M

H
H3
)(

V2 V1
C2 C1
L3 L5
p (bar)

CURVE CARATTERISTICHE S
PERFORMANCE CURVES L6 L7
25
PRESSIONE / PRESSURE -

20 V1

S2
15 C2
C1

S1
10
C2
5 V2 V2
C2 V2
0 20 40 60 80 100 L1 L
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


150 5.5 118 31.5 56.5 95.5 70 40 90 40.5 29.5 120 43.4 62 35 64 64 8.5
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


TENSIONE NOMINALE NOMINAL VOLTAGE PIOMBATURA CODE
24 V DC 916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
V1, V2, C1, C2 3/4"G
B070660.01.00 4:1 100-350 bar 350 bar 110 bar/turn 100 l/min 350 bar 5.6 kg
M 1/4"G
Pag. 07.15.02

Valvola di blocco bilanciata doppia angiabile con circuito rigenerativo


Flangeable dual overcenter valve with regenerative circuit

F F1

V2 V1

=
S2
S
C2 C1

=
S1
2
3 ==
D (n.2) F2
1
L HEX32
L1 L2
HEX41 H2
V2 V1
L3

H1
2 1
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

D1 (n.4)
30 3
PRESSIONE / PRESSURE -

25
20 C2
=
H5

H
15
C1
=

C2 C1
10

H3
H4

5 C1 V1
V1 C1 L5 L4
0 44 88 132 176 220
L6 L7 O-RING
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


154 59 33 14 88 33 9 136 90 52 50.8 165 59.5 65 65.5 40.5 50 33 58.5 23.8 19 10.5 OR 4093 23.39x3.53
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 H4 H5 F F1 F2 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Setting Increase Flow Pressure
1 200-480 bar 480 bar 95 bar/turn V1, V2 3/4"SAE6000
A078290.01.00 6:1 220 l/min 500 bar 16.6 kg
2 120-360 bar 350 bar 60 bar/turn C1, C2 18
Pag. 07.15.03

Valvola di blocco bilanciata doppia angiabile con circuito rigenerativo


Flangeable dual overcenter valve with regenerative circuit

L9 L10
O-RING
C2 C1
2

H1
3 5
C2
2

H2
H5

H3

H
1 4 4
5 C1
3

H4
1

V2 V1 L7 L8

H6
L6 HEX41
HEX32
L5
CURVE CARATTERISTICHE
p (bar)

= =

S4
PERFORMANCE CURVES
35
30
PRESSIONE / PRESSURE -

=
25

S1
S
S5
20 C2
V1 =
V2 V1
15 C1
C1

S2
10
C1

S3
L4
S6

5 V1
L3
0 80 160 240 320 400 L L1
PORTATA / FLOW - Q (l/min)
L2

Corpo in acciaio / Steel body


158 59.5 226.5 120 54 31.6 54 57 71.5 65 71.5 110 50 30 50 4.5 66.7 16.65 154 49 56 78 38 136 9 SAE SEAL 1-1/4" 75 SH
L L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 S S1 S2 S3 S4 S5 S6 H H1 H2 H3 H4 H5 H6 O-RING

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Peso


Dimensione Porte
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Range Standard


Setting
Pressure
Increase
Max
Flow
Max
Pressure Port Size Weight
1 200-480 bar 480 bar 95 bar/turn V1, V2 1"1/4 SAE6000
A078590.01.00 6:1 400 l/min 500 bar 18.8 kg
2-3 120-360 bar 250 bar 60 bar/turn C1, C2 28
Pag. 07.15.04

Valvola di blocco bilanciata doppia angiabile con circuito rigenerativo


Flangeable dual overcenter valve with regenerative circuit

L
C3 C2 C1
L3 L1 L2

L4
Vu2 2 C3 C1
3 Vu1

optional
EV
1 Vu3 Plug for
optional EV

1 2 HEX32
S4
HEX24
= = 3

V2 V1

H2
VU3

H1

H3
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES

==
H
25 C2
PRESSIONE / PRESSURE -

20 O-RING
15 S1
10 HEX13 S3 HEX10
C2 C2 S2 S
5 V2
V2 C1
C2 F1 F2 F3
0 20 40 60 80 100 120 D1

PORTATA / FLOW - Q (l/min) V2 V1

F4
F6
F

VOLTAGGIO NOMINALE NOMINAL VOLTAGE

26 VDC
D (n4)
F5

Corpo in alluminio / Aluminium body


B070690.03.00 148 109 19 20 19.5 148 4.5 12 75 47.6 175 73 60 22.2 110 20 109 19 5 4.5 22 10.5 19 OR 23.39x3.53
COD. L L1 L2 L3 L4 S S1 S2 S3 S4 H H1 H2 H3 F F1 F2 F3 F4 F5 F6 D D1 O-RING

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Code Range Setting Increase Flow Pressure
1 100-350
bar 350 bar 108 bar/turn V1-V2-C1-C3 3/4"G
B070690.03.00 4:1 120 l/min 350 bar 8.64 kg
2 120-360
bar 350 bar 70 bar/turn C2 3/4"SAE3000
Pag. 07.16.01

Valvola di blocco bilanciata doppia angiabile per motori idraulici


Dual overcentre valve, angeable for hydraulic motors

L1 L

1 2

CURVE CARATTERISTICHE
PERFORMANCE CURVES

30
3/4G
25
PRESSIONE / PRESSURE - p (bar)

20
V2 S2 L3 L2
15
10 C2 S4 S3 1 3 2
5 C2
S1 S
V2
0 15 30 45 60 75 90 105 120 135 150

PORTATA / FLOW - Q (l/min)


36
1G
30
24
V2

F
18

F1
12 C2

6 C2
V2
0 30 60 90 120 150 180 210 240 270 300 L4 L4
PORTATA / FLOW - Q (l/min) L3 L2 L3

Corpo in acciaio / Steel body


A078281.03.00 150 4.5 75 37.5 50.8 109 4.5 22 25 50 109 ~46 38.5 79 48 25 23.8 24 10.5 (n.6) 16.5 10.8 Kg
A078281.02.00 150 4.5 75 37.5 50.8 109 4.5 22 25 50 109 ~46 38.5 79 48 25 23.8 24 10.5 (n.6) 18.5 10.8 Kg
A078281.07.00 165 4.5 84 40.5 57.2 140 4.5 20 20 64 139 ~46 50 115.5 85 25 27.7 33 10.5 (n.8) 18.5 20.6 Kg
COD. L L1 L2 L3 L4 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 F F1 D D1 Weight

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per valve for hydraulic motors SH7V
motori idraulici SH7V e F12. and F12.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size
Code Range Setting Increase Pressure
1 100-420 bar 380 bar 82 bar/turn C1, C2 3/4SAE6000
4:1
A078281.03.00 2 100-420 bar 380 bar 82 bar/turn 150 L/min 420 bar V1, V2 3/4G
- 3 15-45 bar 30 bar 10.5 bar/turn M1, M2, C3, Dr 1/4G
1 100-420 bar 380 bar 82 bar/turn C1, C2 3/4SAE6000
8:1
A078281.02.00 2 100-420 bar 380 bar 82 bar/turn 150 L/min 420 bar V1, V2 3/4G
- 3 15-45 bar 30 bar 10.5 bar/turn M1, M2, C3, Dr 1/4G
1 150-420 bar 380 bar 95 bar/turn C1, C2 1SAE6000
6:1
A078281.07.00 2 150-420 bar 380 bar 95 bar/turn 300 L/min 420 bar V1, V2 1G
- 3 15-45 bar 30 bar 10.5 bar/turn M1, M2, C3, Dr 1/4G
Pag. 07.16.02

Valvola di blocco bilanciata doppia angiabile per motori idraulici


Dual overcentre valve, angeable for hydraulic motors

O-RING
L3 L4

C1 C2

=
H4

H5
==
Dr

=
M1 1 2 M2 M1

F
C3
F1
= =
H
Dr Dr L5 H1
3 8)
C3 C3
V2 (n.
D
2

L2
V1 V2

L1
L
CURVE CARATTERISTICHE 3
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

30
1
25

20 V1 H2
V2 H3
15
C2
S3
10 S2
S1

C2
S

5 C3 M2
V2 Dr
0
30 60 90 120 150 180 210 240 270 300

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A078481.06.00 170 95 37.5 84 43 57.2 100 84.5 35 25 110 82 64 60 27.7 60 14 30 12.5 10 kg
A078581.03.00 200 110 45 99 50.5 66.7 129 109 60 40 130 95 65 60 31.8 60 40 30 14.5 12 kg
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 H5 F F1 D WEIGHT

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura valve for hydraulic motors SH11C.
per motori idraulici SH11C.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size
Code Range Setting Increase Pressure
8:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1"SAE6000
A078481.06.00 300 l/min 350 bar
- 3 10-70 bar 20 bar 16.5 bar/turn M1, M2, C3, Dr 1/4"G
8:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1-1/4"SAE6000
A078581.03.00 300 l/min 350 bar
- 3 15-45 bar 20 bar 10.5 bar/turn M1, M2, C3, Dr 1/4"G
Pag. 07.16.03

Valvola di blocco bilanciata doppia angiabile per motori idraulici


Dual overcenter valve, angeable for hydraulic motors

L5
= =

C1 C2
F
M1 M2 F1
1 2

D (n.8)
Dr V1

D1 (n.8)
3
C3 V1 V2
V1 V2
C1 C2

H3
=

D2 (n.8)
H1
M1

H4
H2

=
F2
L2 L1 L2 S3
L
SEA seal (Zurcon)
L4 L3 L4

C3
Dr
S
S1

1 3 2 S2
Corpo in acciaio / Steel body
A078281.01.00 149 66 41.5 60 44.5 23.8 65 54 49 30 129 50.8 33 88 33 20.5 18 11 M10 17 10.5 9 kg
A078481.01.00 180 82 49 60 60 27.8 75 64 57 12 155 57.2 41 107 31 22 20 12 M12 19 12.5 15 kg
A078481.05.00 180 75 52.5 60 60 27.8 75 64 56.5 35 155 57.2 41 107 41 22 20 12 M12 19 12.5 15 kg
A078581.01.00 200 92 54 60 70 31.8 75 64 57 12 160 66.7 44 112 34.5 24 22 14 M14x2 22 14.5 17 kg
A078581.02.00 200 83 58.5 60 70 31.8 75 64 58 36 160 66.7 44 112 44 28 26 12 M14x2 22 14.5 15 kg
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 H4 F F1 F2 D D1 D2 WEIGHT

DESCRIZIONE DESCRIPTION

Valvola di blocco bilanciata Dual angeable overcenter


doppia con angiatura per motori valve for hydraulic motors
idraulici SH7V e F12. SH7V and F12.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max
Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size
Code Range Setting Increase Pressure
4:1 1,2 180-350 bar 300 bar 88 bar/turn V1, V2, C1, C2 3/4"SAE6000
A078281.01.00 120 l/min 350 bar
- 3 35-80 bar 70 bar 25 bar/turn M1, M2, C3, Dr 1/4"G
4.5:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1"SAE6000
A078481.01.00 300 l/min 350 bar
- 3 10-45 bar 20 bar 10.5 bar/turn M1, M2, C3, Dr 1/4"G
4.5:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1"SAE6000
A078481.05.00 300 l/min 350 bar
- 3 10-70 bar 70 bar 25 bar/turn M1, M2, C3, Dr 1/4"G
4.5:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1-1/4"SAE6000
A078581.01.00 300 l/min 350 bar
- 3 10-45 bar 20 bar 10.5 bar/turn M1, M2, C3, Dr 1/4"G
4.5:1 1,2 140-350 bar 350 bar 130 bar/turn V1, V2, C1, C2 1-1/4"SAE6000
A078581.02.00 300 l/min 350 bar
- 3 10-70 bar 70 bar 25 bar/turn M1, M2, C3, Dr 1/4"G
Pag. 07.15.05

Valvola di blocco bilanciata doppia in linea con circuito rigenerativo serie 210
Dual overcenter valve in line with regenerative circuit "210 series"

plug for Ev1


F1 Str Vu3

A1 B1

F3
F6

F4
Vu1 2

F5
Vu2 F2 A
optional S S1
Ev2 OVC1 F
Ev1 1 Str
Vu3 L1 L B
1.2 0.5
HEX32
A B 2

VU1

H1

H
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
H2

D1
D
50
40
L2 S2
30 B1 1
G4 B1 VU2
A1 HEX24
20 G1
B B1
10 B
B1
0
G5
G3

G2

G
30 60 90 120 150 180
PORTATA / FLOW - Q (l/min)

L4 Ev2
A1
L3
OVC2
Corpo in alluminio / Aluminium body
B070660.04.00 148 12 10.2 127 80 99 4.5 10.5 174 22.2 71 127 33 77 79.5 42 30 41 74 33 71.5 21.5 82 77 10.5 16.5
COD. L L1 L2 L3 L4 S S1 S2 H H1 H2 F F1 F2 F3 F4 F5 F6 G G1 G2 G3 G4 G5 D D1

DESCRIZIONE DESCRIPTION

La valvola oltre alle normali The valve combines the normal


funzioni delle valvole di blocco functions of the overcentre
permette di sommare lolio valves with the regenerative
scaricato dal lato stelo function, adding the return ow
alla portata della pompa, from the rod side to the pump
permettendo di velocizzare ow, to reduce the extension
luscita stelo. Durante lo slo time. During the extension,
la spinta del cilindro equivale the thrust of the cylinder
alla sola pressione agente matches only the pressure
sulla sezione dello stelo. operating on the rod section.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916013

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per Giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
1 100-350 bar 350 bar 108 bar/turn
B070660.04.00 4:1 180 l/min 350 bar 3/4"G 7.8 kg
2 170-350 bar 350 bar 70 bar/turn
Valvole controllo rotazione - Rotation control valves

Valvole controllo
rotazione
Rotation control valves

Sono utilizzate per controllare il bloc- These valves are utilised to control the
caggio e il movimento di cilindri o moto- stop and the motion of cylinders and
ri idraulici che comandano la rotazione hydraulic motors for the rotation of
di carichi sospesi. Cilindri e motori sono hanged loads. Symmetrical capacity of
caratterizzati da cilindrate simmetriche both the rotation direction is typical of
nei due sensi di rotazione. motors and cylinders for this application.

C2 C1
3 4
C1 C2
2 1

12
3 4
6 5

V2 V1 T

C3

V1 V2

Le valvole possono essere composte da: The valves can be composed by:
- valvola di massima pressione doppia - dual crossed relief pressure valve: it
incrociata: controlla eventuali picchi di controls any pressure peaks coming
pressione derivanti da urti o sovraccari- from overloads or shocks that could
chi che potrebbero danneggiare i com- damage the system components;
ponenti del sistema;
- valvole per la regolazione della veloci- - motion speed control valves: for this
t di movimento: si utilizzano strozzatori operation restriction check valves or
unidirezionali oppure regolatori di porta- pressure compensated flow control
ta compensati baricamente; valves are utilised;
Valvole controllo rotazione - Rotation control valves

- valvole per il blocco del carico: si impiegano - load hold valves: for this task overcenter
valvole overcenter oppure valvole di blocco; valves or check valves are utilised;
- una valvola selettrice che preleva il se- - a pressure selecting valve that picks up
gnale di pressione dal ramo caratterizza- the signal from the highest pressure side.
to dalla pressione maggiore.

Svolgono pertanto le seguenti funzioni: The valves grant the following functions:
- Controllo della pressione di spunto o in - To limit the starting pressure or in case
caso di urto; of shocks;
- controllo della velocit di rotazione - To control the rotation spees of the
dellattuatore; actuator;
- blocco e sostentamento del carico con - To hold the load with the spool valve
distributore in neutro o pompa ferma. in neutral position or with the pump not
running.
Lattacco C3 serve per il collegamento al
freno. C3 is the connection to the brake.
Per il controllo dei motori idraulici ge- A high pilot ratio is usually utilised a
neralmente adottato un elevato rappor- high pilot ratio to control the hydraulic
to di pilotaggio. La scelta del valore op- motors. The right pilot ratio value
portuno di R deve per tener conto della depends however on the following
seguente considerazione: consideration:
la pressione di pilotaggio deve essere pilot pressure has to be enough to open
alta abbastanza da aprire la valvola over- the overcenter valve while maintaining
center e allo stesso tempo deve essere the motor brake open (about 15-20 bar).
sufficiente per mantenere aperto il fre-
no motore (circa 15-20 bar). For hydraulic motors pilot pressure
Con motori idraulici, la pressione di pi- necessary to open the overcenter valve
lotaggio necessaria ad aprire la valvola can be calculated as follows:
overcenter pu essere calcolata utiliz-
zando la seguente formula:

La pi piccola pressione di pilotaggio : The lowest pilot pressure is:

Dove: Where:
Ppil = pressione di pilotaggio Ppil = pilot pressure
Ptr = pressione di taratura Ptr = setting pressure
Pload = pressione indotta dal acrico R = pilot ratio
R = rapporto di pilotaggio
Speed control using restrictors provokes
La regolazione della velocit mediante a heating of the fluid and could make
strozzatori porta ad un riscaldamento the use of a heat exchanger necessary.
dellolio e potrebbe richiedere il mon-
taggio di uno scambiatore di calore.
Pag. 08.01.01

Valvola controllo rotazione


Rotation control valve

L2 L1

V1

S1

S3
C1 C2

S2
HEX5
1 2
V2
HEX17

H1
T

V1 V2 C1 C2
p (bar)

H4
H
CURVE CARATTERISTICHE T
PERFORMANCE CURVES

H3
30
V1 V2
PRESSIONE / PRESSURE -

25

H5
20 D
H2 (n
.2)
15
V2
10 C2
C2 C2
5 V2

S2
S

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

S1
C1
L2 L1
L

Corpo in alluminio / Aluminium body

B080401.01.00 88 43 22.5 88 24 40 18 110 67 9.5 39.5 94 8 M8


COD. L L1 L2 S S1 S2 S3 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

La valvola assicura il controllo The valve allows


dinamico della rotazione the dynamic control
e della pressione in spunto of the load rotation
o in caso di contro rotazione. and to limit the inlet
L'olio viene scaricato sul ramo pressure during
opposto grazie alle valvole the starting or in case
di non ritorno integrate of reverse movement.
nel blocco. L'attacco T permette The port T can be used
di compensare eventuali perdite to compensated any drain
d'olio per drenaggio del motore. of oil of the motor.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
B080401.01.00 10.7:1 90-350 bar 175 bar 110 bar/turn 60 l/min 350 bar 1/2"G 2.9 kg
Pag. 08.01.02

Valvola controllo rotazione


Rotation control valve

S5
L3 L2

V2
C1 C2

S4
1 2

S
3 4

S2
V1 HEX5
S1
L1 L
T S2 HEX17

C3

H1
V1 V2 2 1

D (n.2)
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES C2 C1 C1 C2
25
PRESSIONE / PRESSURE -

20 T

H4
H

15

H6
V2 L4
10
C2 C3
H3

H5
5 C2
V2
0
H2

20 40 60 80 100
4 3
PORTATA / FLOW - Q (l/min) S3 HEX13
HEX4

Corpo in alluminio / Aluminium body


B080404.01.00 99 11.5 50 24.5 11.5 99 74.5 24.5 28 50 4.8 123 ~75 ~45.8 19.5 95 15 83 M10
COD. L L1 L2 L3 L4 S S1 S2 S3 S4 S5 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

La valvola assicura il controllo The valve allows the dynamic


dinamico della rotazione control of the load rotation
e della pressione in spunto and to limit the inlet
o in caso di contro rotazione. pressure during the starting
L'olio viene scaricato sul ramo or in case of reverse movement.
opposto grazie alle valvole The port T can be used
di non ritorno integrate to compensated any drain
nel blocco. L'attacco T permette of oil of the motor.
di compensare eventuali perdite The pressure on V1or V2
d'olio per drenaggio del motore. is directed by the shuttle
Tramite C3 e la selettrice interna valve to the spring brake
la pressione sul ramo V1 o V2 for brake releasing.
viene inviata al freno per la sua The brake must open in
apertura, che deve avvenire advance to the valve piloting.
in anticipo al pilotaggio valvola.

Codice Rapporto di Campo di Taratura Portata Pressione Dimensione Porte Peso


Ordinazione Pilotaggio Taratura Standard Massima Max

Ordering Code Pilot Ratio Pressure Range Standard Max Flow Max Port Size
Setting Pressure Weight
1-2 100-350 bar 180 bar V1, V1, C1, C2 1/2"G
B080404.01.00 7.6:1 100 l/min 350 bar 5 kg
3-4 10-100 bar 25 bar C3 1/4"G
Pag. 08.02.03
Valvola controllo rotazione con valvola di sovrapressione incrociata
e regolatori di portata
Rotation control valves with dual cross-line relief valves and ow regulators

HEX13
C2 C1 Vista A / View A V1 V2
3 4 HEX4
2 1

6 5

Ruotare in senso orario


V2 V1 per incrementare la velocit
Turn clockwise to increase speed
C1

H6
L5 L5 L2
SFIATO/AIR BLEED
A
HEX13 SFIATO / AIR BLEED

L2 L L1
p (bar)

S1 S S2

H4
CURVE CARATTERISTICHE
PERFORMANCE CURVES
25 C2
C2
PRESSIONE / PRESSURE -

H3
20
V1
4
C1 2
15
H

C1 V1 3
10 V1

H5
C1 V2
5 1 C1
H2

0 D(n.2) HEX 17
H1

10 20 30 40 50 60 S3 S4 L1 L4 L3
PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


A080402.03.00 100 ~42 48 37 31.5 15 85 10 8.5 35 28.5 80 14 20 37.5 14 37.5 6 6.5
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

La valvola composta The valve consist of dierent


da varie sezioni integrate section integrated in one block:
in un unico blocco: una sezione one section is dedicated
dedicata alla regolazione to regulate the ow
della portata, per limitare for the rotation, the second
la velocit di rotazione, one to ensure the lock
la seconda per assicurare and control of the load
il blocco e il controllo rotazione rotation, the third one
del carico, la terza con funzione to limit the max pressure
di limitazione della pressione in case of shocks
massima in spunto o in caso or at the starting.
di urti. Diagramma realizzato Curves realized with ow
con gli strozzatori restrictors completely open.
completamente aperti.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
1-2 250 bar 135 bar/turn
A080402.03.00 4.3:1 100-350 bar 60 l/min 500 bar 1/2"G 2.5 kg
3-4 220 bar 110 bar/turn
Pag. 08.02.04

Valvola controllo rotazione con valvola OVC doppia e sovrapressione incrociata


Rotation control valve with dual cross-line relief valves and dual OVC valves

C2 C1
SFIATO / AIR BLEED
3 4

2 1
HEX13 V1 V2

HEX4

V2 V1

C1

H4
SFIATO/
AIR BLEED
L6 L5 L2
p (bar)

S1 S
CURVE CARATTERISTICHE L2 L L1
S2 S3

H3
PERFORMANCE CURVES
25 C2
PRESSIONE / PRESSURE -

H1
20 C2

H2
V1 C1
15 4 2
C1 V1
H

10
C1 1 3
5 V1

H2
V2
H1

H3
0 C1
10 20 30 40 50 60
H1

PORTATA / FLOW - Q (l/min) L1 L3 L4 D (n.2) HEX17

Corpo in alluminio / Aluminium body


A080402.06.00 100 ~42 48 31.5 37 70 15 85 10 35 28.5 80 20 37.5 14 6 6.5
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola composta The valve consist


da due sezioni integrate of two sections integrated
in un unico blocco: una sezione in one block: one section
per assicurare il blocco is dedicated to ensure
e il controllo rotazione the lock and control
del carico, la seconda of the load rotation,
con funzione di limitazione the second one to limit
della pressione massima the max pressure in case
in spunto o in caso di urti. of shocks or at the starting.
La valvola selettrice The shuttle valve for
per l'attacco freno completa the spring negative
il blocco. Diagramma brake full the block.
realizzato con gli strozzatori Curves realized with ow
completamente aperti. restrictors completely open.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Peso


Ordinazione Pilotaggio Taratura Standard per giro Massima Max Porte

Ordering Code Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
1-2 250 bar 135 bar/turn
A080402.06.00 4.3:1 100-350 bar 60 l/min 500 bar 1/2"G 2.5 kg
3-4 220 bar 110 bar/turn
Pag. 08.03.01

Valvola controllo rotazione


Rotation control valve

L6
L5
V2
4
C1 C2

S
1 2

3 HEX5
3 4
V1 L4 HEX17 S1
L3
T

C3

H1
1 2
V1 V2
p (bar)

CURVE CARATTERISTICHE
C2 C1 C2
PERFORMANCE CURVES
25 T
PRESSIONE / PRESSURE -

20
H

D (n.2)
H2

15
V2 C3 S2

H5
10
H3

C2

H4
5 C2
V2
V2 V1
0 20 40 60 80 100 120
PORTATA / FLOW - Q (l/min) 3 4
L2 L1
HEX13
S3 S4
L HEX4

Corpo in alluminio / Aluminium body


A080602.01.00 130 110 10 97 30 33 100 90 25 20 25 40 130 ~76 100 11 24 62.5 M10
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

La valvola assicura il controllo The valve allows


dinamico della rotazione e the dynamic control
della pressione in spunto of the load rotation
o in caso di contro rotazione. and to limit the inlet
L'olio viene scaricato sul ramo pressure during the starting
opposto grazie alle valvole or in case of reverse
di non ritorno integrate movement. The port T
nel blocco. L'attacco T permette can be used to compensated
di compensare eventuali perdite any drain of oil of the motor.
d'olio per drenaggio del motore. The pressure on V1or V2
Tramite C3 e la selettrice interna is directed by the shuttle
la pressione sul ramo V1 o V2 valve to the spring brake
CODICE ORDINAZIONE SEALING ORDERING viene inviata al freno per la sua for brake releasing. The brake
PIOMBATURA CODE apertura, che deve avvenire must open in advance
in anticipo al pilotaggio valvola. to the valve piloting.
916003 - 916005

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
1-2 180 bar 40 bar/turn V1, V2, C1, C2 3/4"G
A080602.01.00 7.6:1 60-210 bar 120 l/min 350 bar T 1/2"G 5.8 kg
3-4 180 bar 19 bar/turn C3 1/4"G
Pag. 08.03.01A

Valvola controllo rotazione


Rotation control valve

C1 C2 S1 S S1 HEX4

S2 HEX13
1 2 D(n2) S3
3 4
4 3

L4

L1
V2 V1

L5
C3

L3
L6
T

L
T

V1 C3 V2 C2 C1

CURVE CARATTERISTICHE

L2
PERFORMANCE CURVES
p (bar)

2 1
25

20 HEX36 S4
PRESSIONE / PRESSURE -

F1

H3
15 V2
T
10 C2
C2

H1
5 C2

H2
V2

H
V2 C1

0 V1
40 80 120 160 200

PORTATA / FLOW - Q (l/min) F F

Corpo in alluminio / Aluminium body


B080804.01.00 158 39 90 24 10 79 125.5 158 18 135 11.5 72 110 79 31 5.5 47 79 M12 5/8"G
COD. L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 H H1 H2 H3 F F1 D T

DESCRIZIONE DESCRIPTION

La valvola assicura il controllo The valve allows the dynamic


dinamico della rotazione e della control of the load rotation
pressione in spunto o in caso and to limit the inlet pressure
di contro rotazione. L'olio viene during the starting
scaricato sul ramo opposto or in case of reverse movement.
grazie alle valvole di non ritorno The port T can be used to
integrate nel blocco. L'attacco T compensated any drain
permette di compensare of oil of the motor.
eventuali perdite d'olio per The pressure on V1or V2
drenaggio del motore. Tramite is directed by the shuttle valve
C3 e la selettrice interna la to the spring brake for brake
pressione sul ramo V1 o V2 releasing. The brake
CODICE ORDINAZIONE SEALING ORDERING viene inviata al freno per la sua must open in advance
PIOMBATURA CODE apertura, che deve avvenire to the valve piloting.
in anticipo al pilotaggio valvola.
916003

Codice Rapporto Campo di Taratura Incremento Portata Pressione


Ordinazione di pilotaggio Taratura Standard per giro Massima Max Dimensione Porte Peso

Ordering Pilot Ratio Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
B080804.01.00 8:1 100-350 bar 350 bar 66 bar/turn 200 l/min 350 bar V1-V2-C1-C2 1"G 8.8 kg
C3 1/4"G
Pag. 08.03.02

Valvola controllo rotazione


Rotation control valve

C2 C1 S
S1
3
S2
4 2 1 S3
V2 V1 HEX5

HEX17

2 1 3 4

H1

H6
X

S4
V2 V1
p (bar)

CURVE CARATTERISTICHE
D (n.6)

H2
PERFORMANCE CURVES
X

H5
25
PRESSIONE / PRESSURE -

20
V2
15
C2 C2 C1 S6 S5

H4
C2

H3
10 L4 L3
V2
L2 L1 S7
5
L
0 18 36 54 72 81
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A080402.12.00 88 68 10 36 26 70 55 52 18 10 44 8 54 100 74 54 8 16 63 ~51.4 M8
COD. L L1 L2 L3 L4 S S1 S2 S3 S4 S5 S6 S7 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

La valvola assicura il controllo The valve ensures the rotation


dinamico della rotazione dinamic control by controlling
con controllo del blocco the blocking when the
quando il distributore directional valve is in
in posizione neutra. Inoltre neutral position. It has also
ha la funzione di limitazione the maximum pressure
della pressione massima limiting function when any
in spunto o in caso di urti. take-o or any shock occurs.
Tramite la selettrice interna Thanks to the internal selecting
la pressione sul ramo V1 e V2 valve, line V1 and V2 pressure
viene inviata al freno per is supplied to the brake
la sua apertura, la quale deve for its opening, that has
avvenire in anticipo rispetto to occur in advance than
al pilotaggio della valvola. the piloting of the valve.

Codice Rapporto Campo di Taratura Portata Pressione Dimensione Porte Peso


Ordinazione di Pilotaggio Taratura Standard Massima Max

Ordering Code Pilot Ratio Pressure Range Standard Max Flow Max Port Size Weight
Setting Pressure
1-2 60-250 bar 130 bar V1, V2, C1, C2 1/2"G
A080402.12.00 4.3:1 80 l/min 500 bar 4.7 kg
3-4 40-150 bar 100 bar X 1/4"G
Valvole controllo portata con protezione contro la rottura di tubazioni
Flow control valves with protection against hoses breakings

Valvole controllo portata


con protezione contro
la rottura di tubazioni
Flow control valves with protection
against hoses breakings

Sono valvole che montate sulle connes- These are valves installed in the cylinders
sioni dei cilindri sono in grado di bloccare connections, their function is to stop
il libero deflusso dellolio nel caso in cui the outflow of the fluid in case of hoses
si abbia la rottura della tubazione. Allim- breaking. When the flow suddenly
provviso aumentare della portata (flusso increases (reaction flow), the valve closes
di reazione) la valvola entra in funzione and stops the flow, ensuring the load to
chiudendo il flusso e assicurando il bloc- keep the position it had at the break
co del carico nella posizione in cui si tro- instant.
va al momento della rottura.

La taratura della valvola si ottiene rego- Setting pressure is obtained settling the
lando la luce di passaggio T tra piattello gap T between the plate and the body of
e corpo valvola. the valve.

D C
Valvole controllo portata con protezione contro la rottura di tubazioni
Flow control valves with protection against hoses breakings

A richiesta possono essere fornite con Upon request these valves can be
foro calibrato sul disco di chiusura per provided with a calibrate hole on the
consentire la discesa controllata del ca- closing plate to control the lowering of
rico o evitare colpi di ariete nelle tuba- the load, or to avoid fluid blasts in the
zioni lasciando una piccola via di scarico pipes with a little way out of the flow.
allolio. They are available also already installed
Sono disponibili anche montate allinter- inside a steel sleeve.
no di un manicotto in acciaio.
The setting value of the reaction flow
La portata di intervento della valvola, depends also on the fluid viscosity. It is
oltre che dal valore della taratura, in- then recommended to set the valve at
fluenzata anche dalla viscosit dellolio. a 30C of temperature. During its use,
Si consiglia di tarare la valvola con olio a below 30C, the valve will stop lower
30C. Durante il suo esercizio, per tem- flows that the setting flow value, on the
perature inferiori ai 30C, la valvola bloc- contrary, beyond 30C it will stop higher
cher il flusso a portate inferiori rispetto flows than the setting flow value.
al valore di taratura, mentre lo bloccher
a portate superiori per valori di tempera-
tura che eccedono i 30C.
Pag. 09.01.01

Valvole controllo portata con protezione contro la rottura di tubazioni


Flow control valves with protection against hoses breakings

B
C T E

D C

D
A
D C

HEX F
G
H
A
DISTANZA DI REGOLAZIONE - `T` (mm)
REGULATION DISTANCE - `T` (mm)

CURVE CARATTERISTICHE CURVE CARATTERISTICHE


PERFORMANCE CURVES PERFORMANCE CURVES
PRESSIONE - p (bar)

1/4"G 3/8"G 1/2"G 3/4"G


PRESSURE - p (bar)

2.5 8
1/2"G
CON `T` = 1 mm

3/4"G 7
2.0 3/8"G 6
1.5 5
4
1.0 1/4"G 3
0.5 2
1
0 20 40 60 80 100 120 140 160 0 10 20 30 40 50 60 70 80
PORTATA / FLOW - Q (l/min) PORTATA / FLOW - Q (l/min)

A090201.01.00 1/4"G 17.5 8 9.5 8.5 2.4 35 24 5.5


A090301.01.00 3/8"G 23 10.5 12.5 10.5 3.5 37 26 5.5
A090401.01.00 1/2"G 25 12 15 13 4.5 45 30 7
A090601.01.00 3/4"G 30.5 17 18 30.5 6 54 38 7
COD. A B C D E F G H HEX

DESCRIZIONE DESCRIPTION

A richiesta si possono On request, supplyng


fornire con foro calibrato with a gauged hole
sul disco per il controllo on the disk for the
della velocit di discesa. descent speed control.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A090201.01.00 20 l/min 350 bar 1/4"G 0.005 kg
A090301.01.00 40 l/min 350 bar 3/8"G 0.010 kg
A090401.01.00 60 l/min 350 bar 1/2"G 0.020 kg
A090601.01.00 80 l/min 350 bar 3/4"G 0.042 kg
Pag. 09.02.01

Valvole controllo portata con protezione contro la rottura di tubazioni


Flow control valves with protection against hoses breakings

A
D

D C
DISTANZA DI REGOLAZIONE - `T` (mm)
REGULATION DISTANCE - `T` (mm)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

L
2.5 1/2"G 3/4"G
2.0 3/8"G
1.5
1.0 1/4"G
0.5

L1
0 20 40 60 80 100 120 140 160
PORTATA / FLOW - Q (l/min)
C
A

1/4"G 3/8"G 1/2"G 3/4"G


PRESSIONE - p (bar)
PRESSURE - p (bar)

8
CON `T` = 1 mm

7
6
HEX

5
4
3
2
1
0 10 20 30 40 50 60 70 80
PORTATA / FLOW - Q (l/min)

A090251.01.00 1/4"G 50 10 19
A090351.01.00 3/8"G 55 12 22
A090451.01.00 1/2"G 70 14 27
A090651.01.00 3/4"G 75 16 36
COD. A L L1 HEX

DESCRIZIONE DESCRIPTION

A richiesta si possono On request, supplyng


fornire con foro calibrato with a gauged hole
sul disco per il controllo on the disk for the
della velocit di discesa. descent speed control.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A090251.01.00 20 l/min 350 bar 1/4"G 0.075 kg
A090351.01.00 40 l/min 350 bar 3/8"G 0.100 kg
A090451.01.00 60 l/min 350 bar 1/2"G 0.200 kg
A090651.01.00 80 l/min 350 bar 3/4"G 0.380 kg
Valvole selettrici - Shuttle valves

Valvole
selettrici
Shuttle valves

Sono valvole che inviano allattacco C la These valve can select the higher
maggiore tra le due pressioni presenti pressure between two lines A and B
sui rami A e B e bloccano la via verso il sending the signal to the C port and
ramo a pressione minore. locking the way to the lower side.

Sono generalmente utilizzate per lo They are normally used for auxiliary
sblocco dei freni idraulici o per i coman- function such as negative hydraulic
di load sensing. Messe in serie inviano al brakes, or to drive remote pressure
comando load sensing la maggiore tra sensing line. In series in a manifold they
le pressioni di lavoro dellintero impian- drive the max pressure of the circuit to
to idraulico. the load sensing system.

B A
Pag. 10.01.01

Valvola selettrice
Shuttle valve

D
E
H
C
= =
C

L
G
B A

F
B
A

I
p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
10
PRESSIONE / PRESSURE -

8 "G
6 3/8 /2"
G
C C1
B
4 /4"G A/ A/B
2 C1
A/B
0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A100202.02.00 FEMMINA/FEMALE 1/4"G 50 30 40 6.5 27 12 6
A100302.01.00 FEMMINA/FEMALE 3/8"G 70 35 50 6.5 45 16 8
A100402.01.00 FEMMINA/FEMALE 1/2"G 70 30 50 9 40 16 13
COD. PORTS TYPE (A,B) A/B/C D E F G H I L

DESCRIZIONE DESCRIPTION

La valvola invia allattacco C This valve can select


la maggiore tra le due the higher pressure
pressioni presenti sui rami between two lines A and B
A e B e bloccano la via verso sending the signal to the C
il ramo a pressione minore. port and locking the way
Generalmente utilizzata to the lower side. It's normally
per lo sblocco dei freni used for auxiliary function
idraulici o per i comandi such as negative hydraulic
load sensing. Messe in serie brakes, or to drive remote
inviano al comando load pressure sensing line. In series
sensing la maggiore in a manifold they drive the
tra le pressioni di lavoro max pressure of the circuit
dellintero impianto idraulico. to the load sensing system.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A100202.02.00 20 l/min 700 bar 1/4"G 0.4 kg
A100302.01.00 45 l/min 700 bar 3/8"G 0.83 kg
A100402.01.00 60 l/min 700 bar 1/2"G 0.7 kg
Pag. 10.01.02

Valvola selettrice a cartuccia


Cartridge shuttle valve

C
HEX 22
24,8

7,9
B A

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
10
B
8

42,4
6

4 C
2

0
4 8 12 16 20

PORTATA / FLOW - Q (l/min) A


14,2
15,8
CODICE SEDE CAVITY CODE 3/4-16UNF
HBS.93.U.03A (Pag. 99.02.00)

DESCRIZIONE DESCRIPTION

La valvola invia allattacco C This valve can select the higher


la maggiore tra le due pressioni pressure between two lines A
presenti sui rami A e B e bloccano and B sending the signal to the C
la via verso il ramo a pressione port and locking the way to the
minore. Generalmente utilizzata lower side. It's normally used
per lo sblocco dei freni idraulici for auxiliary function such
o per i comandi load sensing. as negative hydraulic brakes, or
Messe in serie inviano al comando to drive remote pressure sensing
load sensing la maggiore tra line. In series in a manifold they
le pressioni di lavoro dellintero drive the max pressure of the
impianto idraulico. circuit to the load sensing system.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

30 Nm

Codice Ordinazione Portata Massima Pressione Max Peso

Ordering Code Max Flow Max Pressure Weight

A600302.13.00 20 l/min 500 bar 0.7 kg


Pag. 10.01.03

Valvola selettrice a cartuccia


Cartridge shuttle valve

E
assemble with
V2 V1 "Loctite 242" V2

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

L
20
16
12
C
8
4

0 10 20 30 40 V1
PORTATA / FLOW - Q (l/min)

CODICE SEDE CAVITY CODE C100100.01.00 20 HEX5 8.65 1/8"G


C100200.01.00 28.5 HEX6 11.5 1/4"G
HBS.02.G.03A (Pag. 99.07.00)
COD. L E D Y

DESCRIZIONE DESCRIPTION

La valvola invia allattacco C This valve can select the higher


la maggiore tra le due pressioni pressure between two lines V1
presenti sui rami V1 e V2 and V2 sending the signal to the
e bloccano la via verso il ramo C port and locking the way to
a pressione minore. Generalmente the lower side. It's normally used
utilizzata per lo sblocco dei freni for auxiliary function such as
idraulici o per i comandi load negative hydraulic brakes, or
sensing. Messe in serie inviano to drive remote pressure sensing
al comando load sensing la line. In series in a manifold they
maggiore tra le pressioni di lavoro drive the max pressure of the
dellintero impianto idraulico. circuit to the load sensing system.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

15 Nm - 30 Nm

Codice Ordinazione Portata Massima Pressione Max Peso

Ordering Code Max Flow Max Pressure Weight

C100100.01.00 10 l/min 350 bar 0.01 kg


C100200.01.00 40 l/min 350 bar 0.02 kg
Valvole strozzatrici - Flow restrictor valves

Valvole
strozzatrici
Flow restrictor valves

Le valvole strozzatrici permettono la The flow restrictor valves allow the


regolazione della portata attraverso la adjustment of the flow by a restriction
strozzatura della via di passaggio olio. of the main pipe. The exceeding fluid is
Lolio in eccedenza va a scarico co n lin- downloaded by the relief valve that is
tervento della valvola di max pressione, always installed on the inlet pipe.
che deve essere sempre prevista sul
ramo di mandata. They are responsible then of an energy
Creano pertanto una dissipazione di dissipation and heat increasing that
energia e riscaldamento dellolio che po- could suggest to install a heat exchanger,
trebbe consigliare il montaggio di uno to limit the max. Temperature of the
scambiatore per limitare la temperatura fluid. They are recommended when the
massima dellimpianto. Se ne consiglia excess of flow is very limited or in low
luso in applicazioni a bassi cicli di lavoro frequency application. Otherwise the
e con poca portata in eccedenza. In tutti use of pressure compensated flow
gli altri casi si consiglia il montaggio di regulator is suggested.
regolatori di portata a tre vie.

B A
Pag. 11.01.01

Valvola strozzatrice unidirezionale


One way ow restrictor valve

L L1

B A Y
E

B A

H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
a bc d
120
PRESSIONE / PRESSURE -

A*

*
A

80
*

* Completamente aperta
A

*
A
B

* Fully open
B

40 B

A B a-b-c-d-e
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

47 30 30 HEX3 1/4"G
60 30 30 HEX3 3/8"G
60 30 30 HEX3 1/2"G
L L1 H E Y

DESCRIZIONE DESCRIPTION

Le valvole strozzatrici permettono The ow restrictor valves


la regolazione della portata allow the adjustment of the ow
attraverso la strozzatura della via by a restriction of the main pipe.
di passaggio olio. Lolio in eccedenza The exceeding uid is downloaded
va a scarico con lintervento by the relief valve that is always
della valvola di max pressione, installed on the inlet pipe.
che deve essere sempre prevista They are responsible then
sul ramo di mandata. of an energy dissipation
Creano pertanto una dissipazione and heat increasing that
di energia e riscaldamento dellolio could suggest to install a heat
che potrebbe consigliare exchanger, to limit the max.
il montaggio di uno scambiatore Temperature of the uid.
per limitare la temperatura massima They are recommended when
dellimpianto. Se ne consiglia luso the excess of ow is very
in applicazioni a bassi cicli limited or in low frequency
CODICE ORDINAZIONE SEALING ORDERING di lavoro e con poca portata application. Otherwise the use
PIOMBATURA CODE in eccedenza. In tutti gli altri of pressure compensated
059240 casi si consiglia il montaggio ow regulator is suggested.
di regolatori di portata a tre vie.

Codice Ordinazione Perdite di Carico* Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Pressure Drops* Max Flow Max Pressure Port Size Weight

A110200.01.00 a 20 l/min 350 bar 1/4"G 0.2 kg


A110200.02.00 b 20 l/min 350 bar 1/4"G 0.2 kg
A110300.01.00 a 40 l/min 350 bar 3/8"G 0.3 kg
A110300.02.00 b 40 l/min 350 bar 3/8"G 0.3 kg
A110400.01.00 c 60 l/min 350 bar 1/2"G 0.3 kg
A110400.02.00 d 60 l/min 350 bar 1/2"G 0.3 kg
Pag. 11.01.02

Valvola strozzatrice unidirezionale


One way ow restrictor valve

L L1

B A Y
E

B A

H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
b
120
a
PRESSIONE / PRESSURE -

80
*
A
*
A

40
B
B

A B * Completamente aperta
* Fully open
0 40 80 120 160 200 240
PORTATA / FLOW - Q (l/min)

84 45 45 HEX3 3/4"G
84 45 45 HEX3 1"G
L L1 H E Y

DESCRIZIONE DESCRIPTION

Le valvole strozzatrici The ow restrictor valves


permettono la regolazione allow the adjustment
della portata attraverso of the ow by a restriction
la strozzatura della of the main pipe. The exceeding
via di passaggio olio. uid is downloaded by
Lolio in eccedenza va a scarico the relief valve that
con lintervento della valvola is always installed on the inlet
di max pressione, che deve pipe. They are responsible
essere sempre prevista sul ramo then of an energy dissipation
di mandata. Creano pertanto and heat increasing that
una dissipazione di energia could suggest to install a heat
e riscaldamento dellolio exchanger, to limit the max.
he potrebbe consigliare Temperature of the uid.
il montaggio di uno scambiatore They are recommended
per limitare la temperatura when the excess of ow
massima dellimpianto. is very limited or in low
Se ne consiglia luso frequency application.
in applicazioni a bassi cicli Otherwise the use
di lavoro e con poca portata of pressure compensated
CODICE ORDINAZIONE SEALING ORDERING in eccedenza. In tutti gli altri ow regulator is suggested.
PIOMBATURA CODE casi si consiglia il montaggio
059240 di regolatori di portata a tre vie.

Codice Ordinazione Perdite di Carico* Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Pressure Drops* Max Flow Max Pressure Port Size Weight
A110600.01.00 a 120 l/min 350 bar 3/4"G 0.85 kg
A110800.01.00 b 240 l/min 350 bar 1"G 0.85 kg
Pag. 11.02.01

Valvola strozzatrice bidirezionale


Bidirectional ow restrictor

L L1
Y
E

B A

B A

H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
a b c
120
A*
PRESSIONE / PRESSURE -

*
A

80
*
A
B

40 B
* Completamente aperta
* Fully open
0 10 20 30 40 50
PORTATA / FLOW - Q (l/min)

47 30 30 HEX3 1/4"G
60 30 30 HEX3 3/8"G
60 30 30 HEX3 1/2"G
L L1 H E Y

DESCRIZIONE DESCRIPTION

Le valvole strozzatrici permettono The ow restrictor valves allow


la regolazione della portata the adjustment of the ow
attraverso la strozzatura by a restriction of the main
della via di passaggio olio. pipe. The exceeding uid
Lolio in eccedenza va a scarico is downloaded by the relief
con lintervento della valvola valve that is always installed
di max pressione, che deve on the inlet pipe.
essere sempre prevista sul ramo They are responsible then
di mandata. Creano pertanto of an energy dissipation
una dissipazione di energia and heat increasing that could
e riscaldamento dellolio suggest to install a heat
che potrebbe consigliare exchanger, to limit the max.
il montaggio di uno scambiatore Temperature of the uid.
per limitare la temperatura They are recommended
massima dellimpianto. when the excess of ow
Se ne consiglia luso is very limited or in low
in applicazioni a bassi cicli frequency application.
di lavoro e con poca portata Otherwise the use of pressure
CODICE ORDINAZIONE SEALING ORDERING in eccedenza. In tutti gli altri casi compensated ow
PIOMBATURA CODE si consiglia il montaggio regulator is suggested.
059240 di regolatori di portata a tre vie.

Codice Ordinazione Perdite di Carico* Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Pressure Drops* Max Flow Max Pressure Port Size Weight
A110210.01.00 a 20 l/min 350 bar 1/4"G 0.2 kg
A110310.01.00 b 40 l/min 350 bar 3/8"G 0.3 kg
A110410.01.00 c 60 l/min 350 bar 1/2"G 0.3 kg
Pag. 11.02.02

Valvola strozzatrice bidirezionale


Bidirectional ow restrictor

L L1

E Y
B A

B A

H
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
b
120
a
PRESSIONE / PRESSURE -

80
*
A

*
A
40
B

B * Completamente aperta
* Fully open
0 40 80 120 160 200 240
PORTATA / FLOW - Q (l/min)

84 45 45 HEX3 3/4"G
84 45 45 HEX3 1"G
L L1 H E Y

DESCRIZIONE DESCRIPTION

Le valvole strozzatrici The ow restrictor valves


permettono la regolazione allow the adjustment
della portata attraverso of the ow by a restriction
la strozzatura della of the main pipe.
via di passaggio olio. The exceeding uid is
Lolio in eccedenza va a scarico downloaded by the
con lintervento della valvola relief valve that is always
di max pressione, che deve essere installed on the inlet pipe.
sempre prevista sul ramo They are responsible then
di mandata. Creano pertanto of an energy dissipation
una dissipazione di energia and heat increasing that could
e riscaldamento dellolio suggest to install a heat
che potrebbe consigliare exchanger, to limit the max.
il montaggio di uno scambiatore Temperature of the uid.
per limitare la temperatura They are recommended
massima dellimpianto. when the excess of ow
Se ne consiglia luso is very limited or in low
in applicazioni a bassi cicli frequency application.
di lavoro e con poca portata Otherwise the use
CODICE ORDINAZIONE SEALING ORDERING in eccedenza. In tutti gli altri of pressure compensated
PIOMBATURA CODE casi si consiglia il montaggio ow regulator is suggested.
di regolatori di portata a tre vie.
059240

Codice Ordinazione Perdite di Carico* Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Pressure Drops* Max Flow Max Pressure Port Size Weight
A110610.01.00 a 120 l/min 350 bar 3/4"G 0.85 kg
A110810.01.00 b 240 l/min 350 bar 1"G 0.85 kg
Pag. 11.03.01

Valvola strozzatrice unidirezionale


One way ow restrictor valve

L3 L2
HEX13

A B

H3
H2
B

H4
H1
H
A

D (n.2)
HEX3

S
S1

L1
L

A110200.10.00 40 20 26 7 30 15 50 59.5 27 10 38.5 6.5


COD. L L1 L2 L3 S S1 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Le valvole strozzatrici permettono The ow restrictor valves


la regolazione della portata allow the adjustment
attraverso la strozzatura of the ow by a restriction
della via di passaggio olio. of the main pipe.
Lolio in eccedenza va a scarico The exceeding uid
con lintervento della valvola is downloaded by the relief
di max pressione, che deve valve that is always installed
essere sempre prevista sul ramo on the inlet pipe.
di mandata. Creano pertanto They are responsible then
una dissipazione di energia of an energy dissipation
e riscaldamento dellolio and heat increasing that could
che potrebbe consigliare suggest to install a heat
il montaggio di uno scambiatore exchanger, to limit the max.
per limitare la temperatura Temperature of the uid.
massima dellimpianto. They are recommended
Se ne consiglia luso in applicazioni when the excess of ow
a bassi cicli di lavoro e con is very limited or in low
poca portata in eccedenza. frequency application.
In tutti gli altri casi si consiglia Otherwise the use
il montaggio di regolatori of pressure compensated
di portata a tre vie. ow regulator is suggested.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A110200.10.00 3 l/min 400 bar 1/4"G 0.2 kg


Pag. 11.04.01

Valvola strozzatrice unidirezionale


One way ow restrictor valve

E
A

CODICE/ X
CODE A B

L
.11 0.3*
.12 0.4*
.13 0.5
.14 0.6
.15 1 X
.16 1.3
.17 1.5
.18 1.75

L1

52 10.5 HEX19
L L1 E

DESCRIZIONE DESCRIPTION

* Il foro diametro 0.3 mm * The calibrated orice


ottenuto da un foro 0.3 mm corresponds
di 0.5 mm con all'interno to a 0.5 mm orice with
un lo d'acciaio di 0.4 mm, an internal steel wire 0.4 mm,
mentre il foro con diametro and the orice 0.4 mm
0.4 mm ottenuto da un foro corresponds to a 0.5 mm
di 0.5 mm con all'interno orice with an internal steel
un lo d'acciaio di 0.3 mm wire 0.3 mm for self clearing.
con funzione autopulente.

Codice Ordinazione Portata Massima Coppia di Serraggio Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Installation Torque Max Pressure Port Size Weight
A110200.11.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.12.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.13.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.14.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.15.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.16.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.17.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
A110200.18.00 10 l/min 35 Nm 350 bar 1/4"G 0.1 kg
Pag. 11.05.04

Valvola strozzatrice unidirezionale


One way ow restrictor valve

1 2

L
1
D

Corpo in acciaio / Steel body


A110400.11.00 83 30 45.5
COD. L S D

DESCRIZIONE DESCRIPTION

La valvola strozzatrice permette The ow restrictor valves allow


la regolazione della portata the adjustment of the ow by
attraverso la strozzatura a restriction of the main pipe.
della via di passaggio olio.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A110400.11.00 70 l/min 350 bar 1/2"G 0.7 kg


Valvole unidirezionali - Check valves

Valvole
unidirezionali
Check valves

Sono valvole on/off che consentono flus- These valves allow free flow in a direction
so libero in un verso e lo bloccano nel and stop it in the opposite direction.
verso contrario.
They are built in hexagonal bodies made
Vengono realizzate in corpi esagonali in of steel, suitable to be mounted in line
acciaio adatti ad essere montati in linea with the hoses.
con i tubi. Sono disponibili con 3 diversi They are available with 3 different setting
valori di taratura: 0.5 bar, 2 bar, 5 bar. values: 0.5 bar, 2 bar, 5 bar.

B A
Pag. 12.01.01

Valvola unidirezionale
Check valve

Y
B
B A

CURVE CARATTERISTICHE
PERFORMANCE CURVES

L
PRESSIONE - Dp (bar)
PRESSURE - Dp (bar)

1/4"G 3/8"G
8 4
6 3
4 2
B B
2 A 1 A
0 5 10 15 20 0 10 20 30 40
Y A
PORTATA - Q (l/min) 1/2"G
FLOW - Q (l/min) 2.5
2
1.5 B

E
1
A
0.5
0 10 20 30 40 50 60
PORTATA - Q (l/min)
FLOW - Q (l/min)

65 HEX27 1/2"G
60 HEX24 3/8"G
55 HEX19 1/4"G
L E Y

DESCRIZIONE DESCRIPTION

Sono valvole on/o These valves allow free ow


che consentono usso libero in a direction and stop it
in un verso e lo bloccano in the opposite direction.
nel verso contrario. They are built in hexagonal
Vengono realizzate in corpi bodies made of steel, suitable
esagonali in acciaio adatti to be mounted in line with
ad essere montati in linea the hoses. They are available
con i tubi. Sono disponibili with 3 dierent setting values:
con 3 diversi valori di taratura: 0.5 bar, 2 bar, 5 bar.
0.5 bar, 2 bar, 5 bar.

Codice Ordinazione Taratura Standard Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Standard Setting Max Flow Max Pressure Port Size Weight
A120200.01.00 0.5 bar 15 l/min 700 bar 1/4"G 0.1 kg
A120200.02.00 2 bar 15 l/min 700 bar 1/4"G 0.1 kg
A120200.03.00 5 bar 15 l/min 700 bar 1/4"G 0.1 kg
A120300.01.00 0.5 bar 35 l/min 700 bar 3/8"G 0.17 kg
A120300.02.00 2 bar 35 l/min 700 bar 3/8"G 0.17 kg
A120300.03.00 5 bar 35 l/min 700 bar 3/8"G 0.17 kg
A120400.01.00 0.5 bar 50 l/min 700 bar 1/2"G 0.25 kg
A120400.02.00 2 bar 50 l/min 700 bar 1/2"G 0.25 kg
A120400.03.00 5 bar 50 l/min 700 bar 1/2"G 0.25 kg
Pag. 12.01.02

Valvola unidirezionale
Check valve

Y
B

B A

CURVE CARATTERISTICHE

L
PERFORMANCE CURVES
3/4"G
2.5
p (bar)

2
1.5
1 B
0.5 A
PRESSIONE / PRESSURE -

0 15 30 45 60 75 90
Y A
1"G
2.5
2
1.5 B
1
A E
0.5
0 30 60 90 120 150
PORTATA / FLOW - Q (l/min)

90 HEX42 1"G
85 HEX36 3/4"G
L E Y

DESCRIZIONE DESCRIPTION

Sono valvole on/o These valves allow free ow


che consentono usso libero in a direction and stop it
in un verso e lo bloccano in the opposite direction.
nel verso contrario. They are built in hexagonal
Vengono realizzate in corpi bodies made of steel,
esagonali in acciaio adatti suitable to be mounted in line
ad essere montati in linea with the hoses.
con i tubi. Sono disponibili They are available with 3
con 3 diversi valori di taratura: dierent setting values:
0.5 bar, 2 bar, 5 bar. 0.5 bar, 2 bar, 5 bar.

Codice Ordinazione Taratura Standard Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Standard Setting Max Flow Max Pressure Port Size Weight
A120600.01.00 0.5 bar 90 l/min 700 bar 3/4"G 0.42 kg
A120600.02.00 2 bar 90 l/min 700 bar 3/4"G 0.42 kg
A120600.03.00 5 bar 90 l/min 700 bar 3/4"G 0.42 kg
A120800.01.00 0.5 bar 150 l/min 700 bar 1"G 0.48 kg
A120800.02.00 2 bar 150 l/min 700 bar 1"G 0.48 kg
A120800.03.00 5 bar 150 l/min 700 bar 1"G 0.48 kg
Pag. 12.02.01

Valvola unidirezionale
Check valve

B A

D
Y
A

CURVE CARATTERISTICHE
PERFORMANCE CURVES

1/2"G 1"G
p (bar)

10 15
8 12
6 B 9
B

L
4 A 6 E
PRESSIONE / PRESSURE -

2 3 A
0 10 20 30 40 50 60 0 50 100 150 200 250
3/4"G 1"1/4G
15 25
12 20
9 15
6 B 10 B
3 A 5 A

L1
0 20 40 60 80 100 120 0 100 150 200 250 300 350
PORTATA / FLOW - Q (l/min) PORTATA / FLOW - Q (l/min) Y B

55 102 20 HEX50 1"1/4G


46 82 18 HEX41 1"G
36 69 16 HEX32 3/4"G
30 57 14 HEX27 1/2"G
D L L1 E Y

DESCRIZIONE DESCRIPTION

Sono valvole on/o These valves allow free ow


che consentono usso libero in a direction and stop it
in un verso e lo bloccano in the opposite direction.
nel verso contrario. They are built in hexagonal
Vengono realizzate in corpi bodies made of steel,
esagonali in acciaio adatti suitable to be mounted
ad essere montati in linea in line with the hoses.
con i tubi. Sono disponibili They are available with
con 3 diversi valori di taratura: 3 dierent setting values:
0.5 bar, 2 bar, 5 bar. 0.5 bar, 2 bar, 5 bar.

Codice Ordinazione Pressione di Inizio Portata Massima Pressione Max Dimensione Porte Peso
Apertura

Ordering Code Cracking Pressure Max Flow Max Pressure Port Size Weight
A120410.01.00 10 bar 60 l/min 350 bar 1/2"G 0.25 kg
A120610.01.00 10 bar 130 l/min 350 bar 3/4"G 0.4 kg
A120810.01.00 10 bar 250 l/min 350 bar 1"G 0.8 kg
A121010.01.00 10 bar 350 l/min 350 bar 1"1/4G 1.4 kg
Pag. 12.03.01

Valvola unidirezionale a cartuccia


Cartridge check valve

B A
HEX 24

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

37,7
15

25,7
12

9 B B
A
6

3
A
0
10 20 30 40
PORTATA / FLOW - Q (l/min) M 22x1.5

CODICE SEDE CAVITY CODE

HBS.39.M.02A (Pag. 99.04.00)

DESCRIZIONE DESCRIPTION

Sono valvole on/o che These valves allow free ow


consentono usso libero in un in a direction and stop it in the
verso e lo bloccano nel verso opposite direction. They are built
contrario. Vengono realizzate in in hexagonal bodies made
corpi esagonali in acciaio adatti ad of steel, suitable to be mounted
essere montati in linea con i tubi. in line with the hoses. They are
Sono disponibili con 3 diversi valori available with 3 dierent setting
di taratura: 0.5 bar, 2 bar, 5 bar. values: 0.5 bar, 2 bar, 5 bar.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

45 Nm

Codice Ordinazione Pressione d'inizio Apertura Portata Massima Pressione Max Peso

Ordering Code Cracking Pressure Max Flow Max Pressure Weight

C123900.01.00 4.5 bar 40 l/min 350 bar 0.15 kg


C123900.02.00 9.0 bar 40 l/min 350 bar 0.15 kg
C123900.03.00 30 bar 40 l/min 350 bar 0.15 kg
Pag. 12.03.02

Valvola unidirezionale a cartuccia


Cartridge check valve

B A

HEX 30

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

15

12
B

48,5
9 A

34,5
6
B
3

0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min) A


3/4"G

CODICE SEDE CAVITY CODE

HBS.06.G.02A (Pag. 99.07.01)

DESCRIZIONE DESCRIPTION

Sono valvole on/o che These valves allow free ow


consentono usso libero in in a direction and stop it in the
un verso e lo bloccano nel verso opposite direction. They are built
contrario. Vengono realizzate in in hexagonal bodies made of
corpi esagonali in acciaio adatti ad steel, suitable to be mounted
essere montati in linea con i tubi. in line with the hoses. They are
Sono disponibili con 3 diversi valori available with 3 dierent setting
di taratura: 0.5 bar, 2 bar, 5 bar. values: 0.5 bar, 2 bar, 5 bar.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

100 Nm

Codice Ordinazione Pressione d'inizio Apertura Portata Massima Pressione Max Peso

Ordering Code Cracking Pressure Max Flow Max Pressure Weight

C120600.01.00 6 bar 60 l/min 350 bar 0.15 kg


Pag. 12.03.03

Valvola unidirezionale a cartuccia


Cartridge check valve

B A

HEX 38

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

14
12
10
B
8

68
6 A

44,5
4
B
2
0
30 60 90 120 150

PORTATA / FLOW - Q (l/min) A


1"5/16-12 UN

CODICE SEDE CAVITY CODE

HBS.97.U.02A (Pag. 99.01.01)

DESCRIZIONE DESCRIPTION

Sono valvole on/o che These valves allow free ow


consentono usso libero in un in a direction and stop it in the
verso e lo bloccano nel verso opposite direction. They are built
contrario. Vengono realizzate in in hexagonal bodies made
corpi esagonali in acciaio adatti ad of steel, suitable to be mounted
essere montati in linea con i tubi. in line with the hoses. They are
Sono disponibili con 3 diversi valori available with 3 dierent setting
di taratura: 0.5 bar, 2 bar, 5 bar. values: 0.5 bar, 2 bar, 5 bar.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

90 Nm

Codice Ordinazione Pressione d'inizio Apertura Portata Massima Pressione Max Peso

Ordering Code Cracking Pressure Max Flow Max Pressure Weight

C129700.01.00 4 bar 150 l/min 400 bar 0.3 kg


Valvole controllo portata - Flow control valves

Valvole
controllo portata
Flow control valves

Servono a regolare la portata (funzione These valves are used to regulate the
del regime di rotazione della pompa) di flow in a circuit where the flow, function
un circuito che risulta essere in eccesso of the pump speed, can be higher than
rispetto alle esigenze dellimpianto. Le the flow requested by the circuit itself.
valvole sono compensate alla pressione Valves are pressure compensated and
di lavoro, pertanto la portata pu esse- the flow can be adjusted to a constant
re regolata ad un valore registrabile e value that is not affected by the working
costante indipendentemente dalla pres- pressure of the actuator. In the opposite
sione di lavoro. Nel verso opposto il re- direction the flow regulators act like
golatore perde la sua insensibilit alla normal restrictors, where the flow is
pressione e si comporta come un sempli- a function of the restriction and of the
ce strozzatore. pressure.

Valvole a tre vie: Three way flow regulators:


entrata, ramo regolato e by pass inlet, regulated line, tank line

Servono a regolare la portata ad un va- These valves are generally used to set
lore costante indipendentemente dalla the flow to a constant value without
pressione di lavoro richiesta dallutilizzo being affected by the working pressure
e leccesso viene inviato a scarico. In que- of the actuator, and the exceeding flow
sto modo la pompa lavora sempre alla is diverted to the reservoir tank. So the
pressione richiesta dallutilizzo. Lecces- pump works all time at the pressure
so di portata pu anche essere utilizza- needed by the actuator. The exceeding
to per alimentare un secondo utilizzo, a flow normally goes to the tank, but it can
condizione che la sua pressione di lavoro also be used to supply a second actuator,
sia inferiore a quella che si ha sul ramo a under the condition that the pressure on
portata regolata. this line must be lower than the constant
pressure of the regulated line.
Sullimpianto deve essere prevista una A relief valve must be available before
valvola limitatrice di pressione. Se, infat- the flow regulator. In fact, if the actuator
ti, lutilizzo alimentato dalla portata on the regulated line reaches its end of
Valvole controllo portata - Flow control valves

regolata arriva a fine corsa, il passaggio stroke, the flow across the restrictor will
dolio attraverso la strozzatura regolata be stopped and the internal compensator
si annulla e il compensatore interno chiu- closes the way to the tank.
de il passaggio verso lo scarico.

E R

Valvole a tre vie con doppio utilizzo Three way flow regulators:
in pressione: entrata, ramo regolato, inlet, regulated line, excess line
ramo eccedenza con utilizzo to be used with pressure
in pressione
The exceeding flow is no more sent to
La portata in eccesso non viene pi in- the tank , like it was in the previous type,
viata a scarico, come nella versione pre- but it can be used for a second actuator
cedente, ma pu essere utilizzata per without being affected by its working
alimentare un circuito a pressione anche pressure, higher or lower of the pressure
maggiore della pressione di lavoro del on the regulated line.
ramo regolato.
Questo grazie alla particolare forma del This is a consequence of the particular
compensatore che varia la sezione di shape of the internal compensator
passaggio al ramo regolato o prioritario, that changes the pipe section towards
riducendola per compensare la maggior the regulated flow when the requested
pressione richiesta dal ramo secondario. pressure on the exceeding flow line is
Sul circuito, prima della entrata alla val- higher. A relief valve must be installed
vola stessa occorre prevedere una valvo- before the flow regulator.
la di max. pressione.

E R

B
Pag. 13.01.01

Regolatore di portata 3 vie compensato


Three-way pressure compensated ow regulators

L5 S
S1

H1
E R

R
T

H
H3
E
CURVE CARATTERISTICHE
PORTATA/FLOW - Q (l/min)

PERFORMANCE CURVES
H4

60
50 T
1/2"G
40

H2

D (n.2)
L4
30
HEX34
20 L2 L3
10 3/8"G
L1 L
0 30 60 90 120 150 180 210
PRESSIONE/PRESSURE - p (bar)

Corpo in acciaio / Steel body

90 24.5 64 13 51 20 40 20 90 40 max 6 72 30 6.5


L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve allows a constant


di mantenere costante ow to the port R regardless
la portata inviata alla bocca R of the inlet ow at the port E
indipendentemente dalla and the pressure on line R.
portata in ingresso e dalla The excess of oil is dumped
pressione sulla linea R. to the T line at the working
Lolio in eccesso viene inviato pressure. For correct valve
alla bocca T, per un corretto function the pressure
funzionamento la pressione on the T line must be lower
sulla bocca T deve essere than the pressure
inferiore alla pressione on the R line. Avaiable also
sulla bocca R. Disponibile with aluminium body.
anche con corpo in alluminio.

Codice Ordinazione Pressione Massima Massima Portata Massima Portata Dimensione Porte Peso
di lavoro in Ingresso E Regolata R

Ordering Code Max Working Pressure Max Input Floe E Max Regulated Port Size Weight
Flow R
A130301.01.00 350 bar 55 l/min 30 l/min 3/8"G 2.5 kg
A130401.01.00 350 bar 90 l/min 55 l/min 1/2"G 2.4 kg
Pag. 13.01.02

Regolatore di portata 3 vie compensato


Three-way pressure compensated ow regulators

E R L5 S1

H1
T

CURVE CARATTERISTICHE
PERFORMANCE CURVES R
100
PORTATA/FLOW - Q (l/min)

90
80
70

H
60
H3

50 E
40
30
H4

20
10 T
0 30 60 90 120 150 180 210

H2
L4

D (n.2)
PRESSIONE/PRESSURE - p (bar)
L2 L3 HEX41

L1 L

Corpo in acciao / Steel body


110 20.5 88 12 66 30 50 25 110 38 max 7 87 35 8.5
L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola permette di The valve allows a constant


mantenere costante ow to the port R regardless
la portata inviata alla bocca R of the inlet ow at the port E
indipendentemente dalla and the pressure on line R.
portata in ingresso e dalla The excess of oil is dumped
pressione sulla linea R. to the T line at the working
Lolio in eccesso viene inviato pressure. For correct valve
alla bocca T, per un corretto function the pressure
funzionamento la pressione on the T line must be lower
sulla bocca T deve essere than the pressure
inferiore alla pressione on the R line. Avaiable also
sulla bocca R. Disponibile with aluminium body.
anche con corpo in alluminio.

Codice Ordinazione Pressione Massima Massima Portata Massima Portata Dimensione Porte Peso
di Lavoro in Ingresso E Regolata R

Ordering Code Max Working Pressure Max Input Floe E Max Regulated Port Size Weight
Flow R
A130601.01.00 350 bar 150 l/min 90 l/min 3/4"G 4.3 kg
Pag. 13.01.03

Regolatore di portata 3 vie compensato


Three-way pressure compensated ow regulator

L5 S
S1
E R

H1
T

CURVE CARATTERISTICHE
PERFORMANCE CURVES R
PORTATA/FLOW - Q (l/min)

200
175

H
150 E
H3

125
100
75
H4

50
25 T

H2
0 30 60 90 120 150 180 210

D (n.2)
L4
PRESSIONE/PRESSURE - p (bar) HEX45
L2 L3
L1 L

Corpo in alluminio / Aluminium body


110 33.3 88 12 64 27 50 25 110 38 max 10 87 45 8.5
L L1 L2 L3 L4 L5 S S1 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve allows a constant


di mantenere costante ow to the port R
la portata inviata alla bocca R regardless of the inlet ow
indipendentemente at the port E and the pressure
dalla portata in ingresso on line R. The excess of oil
e dalla pressione sulla linea R. is dumped to the T line
Lolio in eccesso viene inviato at the working pressure.
alla bocca T, per un corretto For correct valve function
funzionamento la pressione the pressure on the T line
sulla bocca T deve essere must be lower than
inferiore alla pressione the pressure on the R line.
sulla bocca R. Disponibile Avaiable also with steel body.
anche con corpo in acciaio.

Codice Ordinazione Pressione Massima Massima Portata Massima Portata Dimensione Porte Peso
di Lavoro in Ingresso E Regolata R

Ordering Code Max Working Pressure Max Input Floe E Max Regulated Port Size Weight
Flow R
B130801.01.00 230 bar 280 l/min 190 l/min 1"G 2.1 kg
Pag. 13.02.01

Regolatore di portata 3 vie compensato con valvola di massima pressione


Three-way compensated ow regulator with relief valve

L4
E R

H1
HEX13
HEX4
T
R

CURVE CARATTERISTICHE
PORTATA/FLOW - Q (l/min)

H
PERFORMANCE CURVES
H3

60

H2
50 E
40
H4

H6
30 T
20
10 L3 = =

H5

D (n.2)
0 30 60 90 120 150 180 210 L1 L2 S S1

PRESSIONE/PRESSURE - p (bar) L

Corpo in alluminio / Aluminium body


90 64 13 51 20 40 31 90 40 max 54.5 72 30 6 30 6.5
L L1 L2 L3 L4 S S1 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve allows a constant


di mantenere costante ow to the port R regardless
la portata inviata alla bocca R of the inlet ow at the port E
indipendentemente dalla and the pressure on line R.
portata in ingresso e dalla The excess of oil is dumped
pressione sulla linea R. to the T line at the working
Lolio in eccesso viene inviato pressure. For correct valve
alla bocca T, per un corretto function the pressure
funzionamento la pressione on the T line must be lower
sulla bocca T deve essere than the pressure on the R line.
inferiore alla pressione sulla A built in relief valve allows
bocca R. Una valvola ausiliaria to limit the max. pressure
limitatrice di pressione serve value in the R line.
a regolare la pressione Once the pressure in the
sulla linea R. Se la pressione R line exceeds the setting
su questa linea supera il valore value the valve will bypass
della valvola ausiliaria parte part of the oil to the line T
dellolio viene inviato alla linea T to limit the max pressure
in modo da limitare la pressione in the R line. All the oil
massima alla linea R. ow is bypassed to T line
Con lattuatore a ne corsa when the actuator reaches
tutto lolio viene bypassato its end of stroke.
sulla linea T. Disponibile anche Avaiable also with steel body.
con corpo in acciaio.

Codice Taratura Campo di Massima Portata Massima Portata Dimensione Porte Peso
Ordinazione Standard Portata in Ingresso E Regolata R

Ordering Code Standard Setting Pressure Range Max Input Floe E Max Regulated Port Size Weight
Flow R
B130405.01.00 200 bar 100-350 bar 90 l/min 55 l/min 1/2"G 1.2 kg
Pag. 13.02.02

Regolatore di portata 3 vie compensato con valvola di massima pressione


Three-way compensated ow regulator with relief valve

L
E R
L1

H1
HEX13
R
T HEX4

CURVE CARATTERISTICHE

H6
PERFORMANCE CURVES
PORTATA / FLOW - Q (l/min)

H
200
175

H4

D(n.2)
150

H2
125 E
H5

100
75

H3
50 T
25 L2 S2
0 30 60 90 120 150 180 210
L3 S S1
PRESSIONE / PRESSURE - p (bar)

Corpo in alluminio / Aluminium body


110 27 10 64 60 36 30 155 33 95 20 75 65 62 8.5
L L1 L2 L3 S S1 S2 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve allows a constant


di mantenere costante ow to the port R regardless
la portata inviata alla bocca R of the inlet ow at the port E
indipendentemente dalla and the pressure on line R.
portata in ingresso e dalla The excess of oil is dumped
pressione sulla linea R. to the T line at the working
Lolio in eccesso viene inviato pressure. For correct valve
alla bocca T, per un corretto function the pressure
funzionamento la pressione on the T line must be lower
sulla bocca T deve essere than the pressure on the R line.
inferiore alla pressione sulla A built in relief valve allows
bocca R. Una valvola ausiliaria to limit the max. pressure
limitatrice di pressione serve value in the R line.
a regolare la pressione sulla Once the pressure in the R line
linea R. Se la pressione exceeds the setting value
su questa linea supera il valore the valve will bypass
della valvola ausiliaria parte part of the oil to the line T
dellolio viene inviato alla linea T to limit the max pressure
in modo da limitare la in the R line. All the oil ow
pressione massima alla linea R. is bypassed to T line
Con lattuatore a ne corsa when the actuator reaches
tutto lolio viene bypassato its end of stroke. Avaiable
sulla linea T. Disponibile also with steel body.
anche con corpo in acciaio.

Codice Taratura Campo di Massima Portata Massima Portata Dimensione Porte Peso
Ordinazione Standard Portata in Ingresso E Regolata R

Ordering Code Standard Setting Pressure Range Max Input Floe E Max Regulated Port Size Weight
Flow R

B130805.01.00 150 bar 100-350 bar 280 l/min 190 l/min 1"G 3.2 kg
Pag. 13.03.01

Regolatore di portata 3 vie compensato per 2 utilizzi


Three-way combination type pressure compensated ow regulator

S
H3 HEX34 = =

E P

L1

D (n.2)
B

CURVE CARATTERISTICHE
PERFORMANCE CURVES
60 60
PORTATA/FLOW - Q (l/min)

50 50 P
40 40
30 30
20 20

L5
1/2"G 1/2"G
L2
10 10 L
60/0 60/0 B
50 50
40 40
30 30

L6
20 20
3/8"G 3/8"G
L4

10 10
0 0
210 150 90 30 0 30 90 150 210 E
L3

PRESSIONE PRESSIONE H2
PRESSURE - p (bar) PRESSURE - p (bar) H H1
B>P P>B

Corpo in alluminio / Aluminium body


130 38.5 110 10 48 37 21 40 70 40 max 6 28 6.5
L L1 L2 L3 L4 L5 L6 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve allows a constant


di mantenere costante ow to the priority port P
la portata inviata alla bocca regardless of the inlet ow
prioritaria P indipendentemente at the port E and of the
dalla portata in ingresso pressure on line P and B.
e dalla pressione sulle linee P The excess of oil is diverted
e B. Lolio in eccesso, inviato to the B line and can be used
alla bocca B, disponibile to feed a second actuator.
per un circuito secondario The working pressure
che pu lavorare a pressione of the second actuator
anche superiore a quella can be higher than
sulla linea P. Disponibile the pressure on line P.
anche con corpo in acciaio. Avaiable also with steel body.

Codice Ordinazione Pressione Massima Massima Portata Massima Portata Dimensione Porte Peso
di Lavoro in Ingresso E Regolata P

Ordering Code Max Working Pressure Max Input Floe E Max Regulated Port Size Weight
Flow P
B130302.01.00 230 bar 55 l/min 30 l/min 3/8"G 1.4 kg
B130402.01.00 230 bar 90 l/min 55 l/min 1/2"G 1.4 kg
Pag. 13.03.02

Regolatore di portata 3 vie compensato per 2 utilizzi


Three-way combination type pressure compensated ow regulator

L7
H3
= =

E P

L1
B

D (n.2)
CURVE CARATTERISTICHE P
PERFORMANCE CURVES
200 200
PORTATA / FLOW - Q (l/min)

160 160
L5
L3
L

120 120
80 80
40 1"G 1"G 40
B
80/0 80/0
70 70
60 60
50 50
L4

40 40
30 30
20
3/4"G 3/4"G 20

L6
10 10 E
L2

0 0
210 150 90 30 0 30 90 150 210
H1
PRESSIONE PRESSIONE H H2
PRESSURE PRESSURE
p (bar) B > P p (bar) P > B

Corpo in alluminio / Aluminium body


B130602.01.00 155 34.5 10 135 57 44 25.5 50 90 7 ~38 8.5
B130802.01.00 150 53.5 10 130 45.5 56.5 28 70 130 10 ~38 8.5
COD. L L1 L2 L3 L4 L5 L6 L7 H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola permette di The valve allows a constant


mantenere costante la portata ow to the priority port P
inviata alla bocca prioritaria P regardless of the inlet ow
indipendentemente dalla at the port E and of the
portata in ingresso pressure on line P and B.
e dalla pressione sulle linee P The excess of oil is diverted
e B. Lolio in eccesso, inviato to the B line and can be used
alla bocca B, disponibile to feed a second actuator.
per un circuito secondario The working pressure
che pu lavorare a pressione of the second actuator
anche superiore a quella can be higher than
sulla linea P. Disponibile the pressure on line P.
anche con corpo in acciaio. Avaiable also with steel body.

Pressione Massima Massima Portata Massima Portata


Codice Ordinazione Dimensione Porte Peso
di lavoro in Ingresso E Regolata P

Ordering Code Max Working Pressure Max Input Floe E Max Regulated Port Size Weight
Flow P
B130602.01.00 230 bar 150 l/min 90 l/min 3/4"G 2.5 kg
B130802.01.00 230 bar 380 l/min 190 l/min 1"G 4.9 kg
Pag. 13.04.01
Regolatore di portata a 3 vie compensato con elettrocomando
e limitatrice di pressione / Pressure compensated ow regulator,
3 ways, with solenoid control and relief valve

2
OPZIONALE/OPTIONAL L4 L5
L6

H1
4 2 HEX13 A B
B A 4
HEX4
L7
3 1

H4
H
3

H3
T
P T
P
D (n.3)

H6

H5
1

H2
L2 L3
CURVE CARATTERISTICHE
PRESSURE / PRESSIONE P [bar]

PERFORMANCE CURVES L1
6 S S1 L
5
4
3 ingresso della pompa resto del circuito
P 1/2"G inlet ow from pump B 1/2"G
2 rest of the circuit
usso regolato drenaggio
A 1/2"G T 1/4"G
1 regulated ow drain

0 25 50 75 100
FLOW / PORTATA (P B) [l/min]

Corpo in acciaio / Steel body


130 56.5 50 29.5 38 35.5 54.5 47.6 40 3 90 45 45.8 60 81.5 8.5 12.5 9
L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Regolatore di portata Pressure compensated


compensato a 3 vie ow regulators, 3 ways,
con elettrocomando with solenoid control
e limitatrice di pressione. and relief valve.
Per garantire un corretto In order to archive the connect
funzionamento opportuno working it's appropriate to
installare su A una valvola mount a check valve
unidirezionale da 10 bar. (setting: almost 10 bar).
Elettrovalvola: 24V standard Solenoid: standard 24V
Max contropressione su T: 1,5 bar. Max back-pressure in T: 1.5 bar
Collettore in acciaio. Body made of steel.

Codice Pressione Portata Max Portata Max Incremento Campo di Taratura Incremento
Max di Regolata sul per giro di Peso
Ordinazione all'ingresso Taratura Standard per giro
Lavoro Prioritario Regolazione

Ordering Max Max Inlet Max Increase Pressure Standard Pressure


Code Working Flow Regulated per Turn Range Setting Increase Weight
Pressure Flow in A
A130403.01.00 350 bar 100 l/min 85 l/min 20 bar/turn 10-150 bar 120 bar 87 bar/turn 3.6 kg
A130403.02.00 350 bar 100 l/min 85 l/min 20 bar/turn 100-350 bar 200 bar 150 bar/turn 3.6 kg
Pag. 13.04.02
Regolatore di portata a 3 vie compensato con elettrocomando
e limitatrice di pressione / Pressure compensated ow regulator,
3 ways, with solenoid control and relief valve

OPZIONALE / OPTIONAL 2
L4 L5
HEX13

H1
4 L6
2 HEX4 A B
B A

3 1 L7

H4
4

H
3

D (n.3)
H3
P T T

H5
H6
1

H2
CURVE CARATTERISTICHE L2 L3
PRESSURE / PRESSIONE P [bar]

PERFORMANCE CURVES HEX13


L1
8 S2 S S1 HEX4
7 L
6
5
4
3 ingresso della pompa B resto del circuito
P 3/4"G inlet ow from pump 3/4"G rest of the circuit
2
usso regolato drenaggio
1 A 3/4"G T 1/4"G
regulated ow drain
0
25 50 75 100 125 150 175 200
FLOW / PORTATA (P B) [l/min]

Corpo in acciaio / Steel body


140 61 50 34 44 37 59 45.5 50 3 25.5 100 43 43.6 69.5 86.5 13.5 13 9
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Regolatore di portata Pressure compensated ow


compensato a 3 vie regulators, 3 ways,
con elettrocomando with solenoid control
e limitatrice di pressione. and relief valve.
Per garantire un corretto In order to archive the connect
funzionamento opportuno working it's appropriate
installare su A una valvola to mount a check valve
unidirezionale da 10 bar. (setting: almost 10 bar).
Elettrovalvola: 24V standard Solenoid: standard 24V
Max contropressione su T: 1,5 bar Max back-pressure in T: 1.5 bar
Collettore in acciaio. Body made of steel.

Codice Pressione Portata Max Portata Max Incremento Campo di Taratura Incremento
Max di Regolata sul per giro di Peso
Ordinazione Lavoro all'ingresso Taratura Standard per giro
Prioritario Regolazione

Ordering Max Max Inlet Max Increase Pressure Standard Pressure


Code Working Flow Regulated per Turn Range Setting Increase Weight
Pressure Flow in A
A130603.01.00 350 bar 200 l/min 140 l/min 20 bar/turn 10-150 bar 120 bar 87 bar/turn 5.1 kg
A130603.02.00 350 bar 200 l/min 140 l/min 20 bar/turn 100-350 bar 200 bar 150 bar/turn 5.1 kg
Pag. 13.04.03
Regolatori di portata compensati a 3 vie con elettrocomando
e limitatrice di pressione / Pressure compensated ow regulator,
3 ways, with solenoid control and relief valve

2
OPZIONALE / OPTIONAL
L4 L5

H1
L6
4 2 HEX13
B A A B
HEX4
L7
3 1
3

H4
4

H
D (n.3)
H3
P T
T

CURVE CARATTERISTICHE P

H5
H6
PERFORMANCE CURVES
PRESSURE / PRESSIONE P [bar]

1 L2 L3

H2
12
L1
11
10
L
9 S S1
8
7
6
5
4 ingresso della pompa B resto del circuito
P 1"G inlet ow from pump 1"G rest of the circuit
3
2 usso regolato drenaggio
1 A 1"G T 1/4"G
regulated ow drain
0 50 100 150 200 250 300
FLOW / PORTATA (P B) [l/min]

Corpo in acciaio / Steel body


173 78 76 36.5 56.5 46.5 74.5 47.4 60 3 120 47 45.5 82.5 105 15 13.5 9
L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Regolatore di portata Pressure compensated ow


compensato a 3 vie regulators, 3 ways,
con elettrocomando with solenoid control
e limitatrice di pressione. and relief valve.
Per garantire un corretto In order to archive the connect
funzionamento opportuno working it's appropriate
installare su A una valvola to mount a check valve.
unidirezionale da 10 bar. (setting: almost 10 bar).
Elettrovalvola: 24V standard Solenoid: standard 24V
Max contropressione su T: 1,5 bar Max back-pressure in T: 1.5 bar
Collettore in acciaio. Body made of steel.

Codice Pressione Portata Max Portata Max Incremento Campo di Taratura Incremento
Max di Regolata sul per giro di Peso
Ordinazione all'ingresso Taratura Standard per giro
Lavoro Prioritario Regolazione
Max Max
Ordering Working Max Inlet Increase Pressure Standard Pressure
Regulated Weight
Code Pressure Flow per Turn Range Setting Increase
Flow in A
A130803.01.00 350 bar 300 l/min 220 l/min 20 bar/turn 10-150 bar 120 bar 87 bar/turn 8.8 kg
A130803.02.00 350 bar 300 l/min 220 l/min 20 bar/turn 100-350 bar 200 bar 150 bar/turn 8.8 kg
Pag. 13.04.04
Regolatore di portata a 3 vie compensato con elettrocomando
e limitatrice di pressione / Pressure compensated ow regulator,
3 ways, with solenoid control and relief valve

OPZIONALE/OPTIONAL 2
L5 L6

4 2 L4

H1
B A
HEX17 A B
HEX5
3 1
L7

H4
4

H
P T

D (n.3)
H3 3

H5
T
P
CURVE CARATTERISTICHE L2 L3

H2

H6
PRESSURE / PRESSIONE P [bar]

PERFORMANCE CURVES L1
1
12
11 S S1 L
10
9
8
7
6
5 ingresso della pompa resto del circuito
4 P 1"1/4G inlet ow from pump B 1"1/4G
3 rest of the circuit
2 usso regolato drenaggio
1 A 1"1/4G T 1/4"G
regulated ow drain
0 50 100 150 200 250 300 350 400
FLOW / PORTATA (P B) [l/min]

Corpo in acciaio / Steel body


190 88.5 76 48 86 62.5 54.5 47.4 65 3 130 47.5 43.6 92 112 18 14 9
L L1 L2 L3 L4 L5 L6 L7 S S1 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Regolatore di portata Pressure compensated ow


compensato a 3 vie regulators, 3 ways,
con elettrocomando with solenoid control
e limitatrice di pressione. and relief valve.
Per garantire un corretto In order to archive the connect
funzionamento opportuno working it's appropriate
installare su A una valvola to mount a check valve.
unidirezionale da 10 bar. (setting: almost 10 bar.)
Elettrovalvola: 24V standard Solenoid: standard 24V
Max contropressione su T: 1,5 bar Max back-pressure in T: 1.5 bar
Collettore in acciaio. Body made of steel.

Pressione Portata Max Incremento


Codice Portata Max Campo di Taratura Incremento
Max di Regolata sul per giro di Peso
Ordinazione all'ingresso Taratura Standard per giro
Lavoro Prioritario Regolazione

Max Max
Ordering Working Max Inlet Regulated Increase Pressure Standard Pressure Weight
Code Pressure Flow Flow in A per Turn Range Setting Increase

A131003.01.00 350 bar 400 l/min 300 l/min 30 bar/turn 10-150 bar 120 bar 87 bar/turn 12 kg
A131003.02.00 350 bar 400 l/min 300 l/min 30 bar/turn 100-350 bar 200 bar 150 bar/turn 12 kg
Pag. 13.05.01

Regolatore di portata a cartuccia 3 vie compensato


Three-way cartridge compensated ow regulator

E P

~ 60.3
B

CURVE CARATTERISTICHE
PERFORMANCE CURVES

12,5
PORTATA/FLOW - Q (l/min)

42
35
M22x1,5
28
1/2
21
14 P
7 3/8
45,8 19
0 30 60 90 120 150 180 210

PRESSIONE/PRESSURE - p (bar)
B

E
CODICE SEDE CAVITY CODE
18
HBS.39.M.03A (Pag. 99.05.01)

DESCRIZIONE DESCRIPTION

La valvola permette di mantenere The valve allows a constant


costante la portata inviata ow to the line P regardless
alla linea P indipendentemente of the inlet ow at the line E
dalla portata in ingresso and the pressure on line P.
e dalla pressione sulla linea P. The excess of oil is dumped
Lolio in eccesso viene inviato to the B line. For correct valve
alla linea B, per un corretto function the pressure
funzionamento la pressione on the B line must be lower
sulla linea B deve essere than the pressure on the P line.
inferiore alla pressione
sulla linea P.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

55 Nm

Codice Ordinazione Portata Massima Regolata Pressione Max Peso

Ordering Code Max Regolated Flow Max Pressure Weight

C133900.01.00 45 l/min 210 bar 0.3 kg


Divisori riunificatori di flusso: una entrata e due uscite - Flow dividers/combiners: one inlet, two exit ports

Divisori riunificatori
di flusso: una entrata
e due uscite
Flow dividers/combiners:
one inlet, two exit ports

Il compito di queste valvole quello di These valves split the flow coming from
separare la portata proveniente da un one line, to one or more flows equal or
unico canale di alimentazione in una o proportional to each other.
pi portate fra loro uguali o proporzio- The percentage by which the exit flows
nali. La percentuale secondo la quale si are split is function of the valve internal
dividono i flussi in uscita funzione dei holes diameter, therefore the flow split
fori di passaggio presenti allinterno del- is not adjustable.
la valvola e pertanto la divisione della
portata fissa e non regolabile.

Usually this valve is utilized in the following


situations:
Solitamente questa valvola viene utiliz- - two actuators (with the same
zata nelle situazioni in cui: dimensions, supplied by the same pump,
- due attuatori (con le stesse dimensio- controlled by the same directional valve,
ni, alimentati dalla stessa pompa, con- without a rigid link between them) have
trollati dalla stessa valvola direzionale, to move in and out simultaneously, each
senza un collegamento rigido tra di essi) one without being affected by the load
devono muoversi in uscita e in rientro operating on the other one;
simultaneamente, senza che il livello di
carico di ciascuno dessi influenzi laltro;
Divisori riunificatori di flusso: una entrata e due uscite - Flow dividers/combiners: one inlet, two exit ports

max

C1 C2

- per luscita sincronizzata di due attua- - for the synchronized exit motion
tori lineari collegati allo stesso carico of two linear actuators linked to the
(per esempio piattaforme di carico, pon- same load (for example load platforms,
teggi, ecc) scaffolds, etc)

Occorre notare, che non sempre possibi- It is important to note that is not always
le ottenere contemporaneamente il rag- possible to obtain the simultaneous
giungimento a fine corsa degli steli. Infatti reaching of the end of stroke of the rods.
nel caso in cui un utilizzo arrivi a fine corsa In fact, in the case of one of the two rods
prima dellaltro, la portata tende ad azze- reaches the end before the other one, the
rarsi anche allaltra bocca. Per permettere flow tends to zero also in the other line.
di raggiungere il fine corsa anche al secon- To reach the end of the stroke also in the
do utilizzo occorre prevedere unapposita other actuator, it must be provided a phase
valvola di rifasamento, che pu essere mu- replacer valve, regardless being equipped
nita o meno di valvola anticavitazione. of an anti-cavitation valve.
Il divisore/riunificatore HBS in grado di HBS flow divider/combiner is able to split
suddividere la portata in ingresso in 2 por- the inlet flow in two outlet flows of the
tate uscenti di pari valore e di mantenere same value, and to maintain equal the two
uguali le portate riunificate nel verso op- re-combined flows in the opposite side
Divisori riunificatori di flusso: una entrata e due uscite - Flow dividers/combiners: one inlet, two exit ports

C1 C2

posto indipendentemente dalla variazione without being affected by the pressure


di pressione generata dai 2 attuatori e dal- drop generated by the two actuators or by
la portata elaborata. the processed flow.
Se il divisore/riunificatore viene utilizzato If the divider/combiner is utilized respecting
rispettando le condizioni operative ripor- the operating conditions explained in the
tate a catalogo, lerrore massimo (emax catalogue, the maximum displacement
nella figura) vale 1.5% della corsa totale. (emax in the picture) is 1.5% of the total
I prodotti riportati a catalogo realizzano stroke. Catalogue showed products,
una divisione del 50%: per divisioni diffe- operate a split of the 50% of the flow:
renti contattare lufficio tecnico. for different divisions please contact our
technical department.
Per la loro caratteristica costruttiva hanno
un ben definito campo di portata nel qua- Every valve has an optimal range of work
le ogni valvola lavora in modo ottimale. Se depending upon their structural features.
la portata in ingresso inferiore o superio- If the inlet flow is higher or lower of the
re al campo della valvola, la stessa perde optimal working range of the valve, the
in precisione, pur continuando a lavorare. valve itself becomes less precise, although
Indipendentemente dalle valvole di rifasa- it keeps to work. Regardless the presence
mento una valvola di max. pressione deve of a phase replacer valve, a pressure relief
essere prevista nellimpianto, prima del di- valve must be provided in the circuit,
visore/riunificatore. before the divider/combiner.
Pag. 14.01.01

Divisori e riunicatori di usso


Flow dividers/combiners

L2
C1 C2 L1 L L1
= =
L3 S
= = = =
C1 C2
A

=
H1
H
p (bar)

CURVE CARATTERISTICHE

=
PERFORMANCE CURVES

=
24
32 40 60
PRESSIONE / PRESSURE -

20
20 A

D (n.3)
16 6 10 = =
12
8 L4
4

0 10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


94 8 110 44 40 35 65 45 7
L L1 L2 L3 L4 S H H1 D

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet


di dividere il usso dolio ow in two equal parts
in ingresso in due portate and keep equal the ows
uguali, indipendentemente in the reverse direction,
dalle pressioni di lavoro regardless of the working
sui due rami. Nel verso pressure on both lines.
opposto mantengono
uguali le portate riunicate.

Campo di Portata
Codice Ordinazione Pressione Max Dimensione Porte Peso
Errore Max: 1.5%

Ordering Code Flow Range Max Peak Pressure Port Size Weight
Max Error: 1.5%
A140300.21.00 3-6 l/min 400 bar 3/8"G 1.5 kg
A140300.22.00 6-10 l/min 400 bar 3/8"G 1.5 kg
A140300.23.00 10-20 l/min 400 bar 3/8"G 1.5 kg
A140300.24.00 20-32 l/min
C1, C2 3/8"G
A140300.25.00 32-40 l/min 400 bar 1.5 kg
A140300.26.00 40-60 l/min A 1/2"G
Pag. 14.01.02

Divisori e riunicatori di usso


Flow dividers/combiner

L2
L1 L L1
L4 L3
D1 (n.2)
C1 C2
B

S4
A

S2

S3
S1
S
C3 C4
C2 C1

S4
X1 X2 D (n.2)
L6 L5
S5 S5

A B B A

H3
C3 C4
H2

H2
CURVE CARATTERISTICHE
PRESSIONE/PRESSURE - p (bar)

PERFORMANCE CURVES

H1
X2 X1
C4 C3
24
H4
32 40

H
20
20
16
6 10
12
8
4
0 C2 C1
10 20 30 40 50 60 L8 L7

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


102 4 110 44 29 29 22 88 7 35 20.5 17.5 14.5 6 20.5 100 66.5 33 22 92.5 7 11
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 S4 S5 H H1 H2 H3 H4 D D1

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet


di dividere il usso dolio ow in two equal parts
in ingresso in due portate and keep equal the ows
uguali, indipendentemente in the reverse direction,
dalle pressioni di lavoro regardless of the working
sui due rami. Nel verso pressure on both lines.
opposto mantengono
uguali le portate riunicate.

Campo di Portata
Codice Ordinazione Pressione Max Dimensione Porte Peso
errore Max: 3%
Ordering Code Flow Range Max Peak Pressure Port Size Weight
Max error: 3%
A140300.31.00 3-6 l/min 400 bar A, B, C1, C2, 1.25 kg
A140300.32.00 6-10 l/min 400 bar C3, C4 3/8"G 1.25 kg
A140300.33.00 10-20 l/min 400 bar 1.25 kg
A140300.34.00 20-32 l/min 400 bar 1.25 kg
X1, X2 1/4"G
A140300.35.00 32-40 l/min 400 bar 1.25 kg
Pag. 14.01.03

Divisori e riunicatori di usso


Flow dividers/combiner

L1 L L1
C1 C2
L3 L2
C1 C2

H
H1
CURVE CARATTERISTICHE
PRESSIONE/PRESSURE - p (bar)

PERFORMANCE CURVES A
L4 L5
20
16 L6 D (n.2)
12
8
=

4
S

0
20 40 60 80 100 120
=

PORTATA / FLOW - Q (l/min)

Corpo in alluminio / Aluminium body


160 12.5 80 40 140 10 80 50 80 10 8.5
L L1 L2 L3 L4 L5 L6 S H H1 D

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet


di dividere il usso dolio ow in two equal parts
in ingresso in due portate and keep equal the ows
uguali, indipendentemente in the reverse direction,
dalle pressioni di lavoro regardless of the working
sui due rami. Nel verso pressure on both lines.
opposto mantengono
uguali le portate riunicate.

Campo di Portata
Codice Ordinazione Pressione Max Dimensione Porte Peso
errore Max: 3%

Ordering Code Flow Range Max Peak Pressure Port Size Weight
Max error: 3%
A 3/4"G
A140400.01.00 50-95 l/min 250 bar 2.2 kg
C1, C2 1/2"G
Pag. 14.01.04

Divisori e riunicatori di usso


Flow dividers/combiner

L1 L L1
L3 L2

C1 C2
C1 C2
0.5

H
V

H1
L4 V
CURVE CARATTERISTICHE
PRESSIONE/PRESSURE - p (bar)

L6 L5
PERFORMANCE CURVES
D (n.2)
20
16
95 150
12
=

8
S

4
=

0
25 50 75 100 125 150
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


160 12.5 80 40 80 140 10 60 90 10 8.5
L L1 L2 L3 L4 L5 L6 S H H1 D

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet


di dividere il usso dolio ow in two equal parts
in ingresso in due portate and keep equal the ows
uguali, indipendentemente in the reverse direction,
dalle pressioni di lavoro regardless of the working
sui due rami. Nel verso pressure on both lines.
opposto mantengono
uguali le portate riunicate.

Codice Ordinazione Campo di Portata Pressione Max Dimensione Porte Peso


errore Max: 3%

Ordering Code Flow Range Max Peak Pressure Port Size Weight
Max error: 3%
V 1"G
A140600.01.00 90-150 l/min 400 bar 6 kg
C1, C2 3/4"G
V 1"G
A140600.02.00 50-95 l/min 400 bar 6 kg
C1, C2 3/4"G
Pag. 14.02.01

Divisore e riunicatore di usso a cartuccia


Flow dividers/combiners cartridge type

C1 C2
25
Hex 22

14
A
7/8-14 UNF
CURVE CARATTERISTICHE
C2
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

24
30 38 45
20

62
15 22 A
16
7
12
8
4 C1
0
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)


15,87
2

17,47
CODICE SEDE CAVITY CODE 19,05

HBS.94.U.04A (Pag. 99.03.00)

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet ow


di dividere il usso dolio in two equal parts and keep
in ingresso in due portate uguali, equal the ows in the reverse
indipendentemente dalle direction, regardless of the
pressioni di lavoro sui due rami. working pressure on both lines.
Nel verso opposto mantengono
uguali le portate riunicate.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

35 Nm

Codice Ordinazione Rapporto di Divisione Portata Massima Pressione Max Peso


all'ingresso
Ordering Code Flow Division Ratio Max Inlet Flow Max Pressure Weight

C141701.01.00 50:50 7 l/min 210 bar 0.1 kg


C141701.02.00 50:50 15 l/min 210 bar 0.1 kg
C141701.03.00 50:50 22 l/min 210 bar 0.1 kg
C141701.04.00 50:50 30 l/min 210 bar 0.1 kg
C141701.05.00 50:50 38 l/min 210 bar 0.1 kg
C141701.06.00 50:50 45 l/min 210 bar 0.1 kg
Pag. 14.02.02

Divisore e riunicatore di usso a cartuccia


Flow dividers/combiners cartridge type

Hex 22
C1 C2

18,95
M 20x1.5
A

C2
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

30
25

84,9
93,5
20 A
15
10
5
0 C1
2 4 6 8 10 12
PORTATA / FLOW - Q (l/min)

15,9
CODICE SEDE CAVITY CODE
16,8
HBS.38.M.04A (Pag. 99.06.00)
17,7

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet ow


di dividere il usso dolio in two equal parts and keep
in ingresso in due portate uguali, equal the ows in the reverse
indipendentemente dalle direction, regardless of the
pressioni di lavoro sui due rami. working pressure on both lines.
Nel verso opposto mantengono
uguali le portate riunicate.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

50 Nm

Codice Ordinazione Rapporto di Divisione Portata Massima Pressione Max Peso


all'ingresso

Ordering Code Flow Division Ratio Max Inlet Flow Max Pressure Weight

C143800.01.00 50:50 12 l/min 350 bar 0.22 kg


Pag. 14.02.03

Divisore e riunicatore di usso a cartuccia


Flow dividers/combiners cartridge type

Hex 32
C1 C2

9,5
1-1/16-12UN

A
C1
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

25 60 90

97,5
99
20 A
15
10
5

0 15 30 45 60 75 90 C2

PORTATA / FLOW - Q (l/min)

CODICE SEDE CAVITY CODE 20,6


HBS.96.U.04A (Pag. 99.03.00) 22,2
23,8

DESCRIZIONE DESCRIPTION

Le valvole permettono These valves split the inlet ow


di dividere il usso dolio in two equal parts and keep
in ingresso in due portate uguali, equal the ows in the reverse
indipendentemente dalle direction, regardless of the
pressioni di lavoro sui due rami. working pressure on both lines.
Nel verso opposto mantengono
uguali le portate riunicate.

COPPIA DI SERRAGGIO INSTALLATION TORQUE

40 Nm

Codice Ordinazione Rapporto di Divisione Portata Massima Pressione Max Peso


all'ingresso
Ordering Code Flow Division Ratio Max Inlet Flow Max Pressure Weight

C149600.01.00 50:50 60 l/min 240 bar 0.3 kg


C149600.02.00 50:50 90 l/min 240 bar 0.3 kg
Deviatori - Diverters

Deviatori
Diverters

Sono utilizzati per deviare manualmente These valves are manually operated to
il flusso in ingresso verso pi uscite se- divert the inlet flow towards different
paratamente. outlet ports.
Sono disponibili: The following models are available:
- deviatori 5/8 - 5 ways-8 positions diverters
- deviatori 8/8 - 8 ways-8 positions diverters
- deviatori 8/2 - 8 ways-2 positions diverters
- deviatori 3/2 - 3 ways-2 positions diverters
- deviatori 4/2 con valvola imitatrice di - 4 ways-2 positions diverters with relief
pressione su unuscita valve on one line
- deviatori 4/2 con valvola imitatrice di - 4 ways-2 positions diverters with a relief
pressione e regolatore di flusso com- pressure valve and a compensated flow
pensato regulator on one line

Sono realizzati con corpo in acciaio. All valves are produced with a steel
manifold.

A B C D

P
Deviatori - Diverters

Deviatori multifunzione Multifunctional diverters

HBS propone alcuni speciali deviatori HBS offers special manual diverters
utilizzati per deviare il flusso verso di- used to switch the inlet flow towards
verse uscite. Sono impiegati, per esem- different outlets. They are used, for
pio, per controllare il movimento e la example, to control the position and
posizione dei cilindri stabilizzatori delle the motion of the stabilizing cylinders
macchine per sollevamento (gru, piatta- of the lifting machines (cranes, aerial
forme aeree etc.). Con lapposito doppio platforms, etc.). With the dual control is
comando possibile eseguire le mano- possible to work by both the sides of the
vre da entrambi i lati della macchina. machines.

B A C D

B A

D C
Pag. 15.01.01

Deviatore manuale 5 vie, 8 posizioni


5-way, 8-position manual diverter

A B C D
L
P Y
8

H3
1
APERTO/OPEN
P A
5
APERTO/OPEN
P C
7 1 B A

2 CHIUSO/CLOSED 6 CHIUSO/CLOSED
6 2 P

H1
L10
L11
APERTO/OPEN APERTO/OPEN
3 7
P B P D

4 CHIUSO/CLOSED 8 CHIUSO/CLOSED 5 3 D C
4
H L3 L1 L2
CURVE CARATTERISTICHE L8 L7
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
1/4"G 1/2"G L9 X
24 12
20 10
16 A 8
D1
D
12 6 P

H2
P P A A
8 4 P L4
4 A 2 Y
0 0
10 20 30 40 10 20 30 40 50 60 L5 L6
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


65 59 6 19 15 12 35 54 29.5 9 50 24.5 35 35 17.5 110 10 16 M10 1/4"G
108 80 28 22 -- 15 50 74 40 7 60 -- 60 30 30 153 -- 14.5 M10 1/2"G
L L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 H H1 H2 H3 D D1 X Y

SCHEMA DI MONTAGGIO / ASSEMBLY GUIDE

B A C D

B A
P

D C

DESCRIZIONE DESCRIPTION

Deviatore rotativo ad 8 posizioni 5-way, 8position diverter


a 5 vie con 4 posizioni di lavoro with four working position
e 4 di tenuta. and four neutral position.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A150201.01.00 40 l/min 700 bar 1/4"G 0.6 kg
A150401.03.00 70 l/min 700 bar 1/2"G 2.3 kg
Pag. 15.01.01A

Deviatore manuale 6 vie 2 posizioni


6-ways 2-positions manual diverter

B A

S2
POS.A POS.B F1
P1 A1 P1 B1

P2 A2 P2 B2
S

S1
F
L5 L6
A1 B1 A2 B2

P1 P2 P2 L4 P1
A B
A2 A1
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
2
1.5 B2 B1

1 L1 L2
A1
0.5 P1 L3 L
0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A150406.01.00 107.5 80 27.5 22 50 40 15 74 60 30 131 60 30 14 7 M10 14.5 50 4
COD. L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 F F1 D D1 D2 D3

DESCRIZIONE DESCRIPTION

Deviatore rotativo a 6 vie 6-way diverter with 2 working


con 2 posizioni di lavoro. positions.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A150406.01.00 60 l/min 400 bar 1/2"G 2.5 kg


Pag. 15.02.01

Deviatore manuale 9 vie, 8 posizioni


9-way, 8-position manual diverter

A B C D E F G H

P
L5

H1
APERTO/OPEN APERTO/OPEN
1 5
P A P E
APERTO/OPEN APERTO/OPEN
2
P D
6
P H
7 8 1 L6 P
APERTO/OPEN APERTO/OPEN

H2
3 7
P C P G
6 2
H

D2
APERTO/OPEN APERTO/OPEN
4 8
P F P B

4
5 3 L4 L3 L3 L3 L7
S1
S D3
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
D1
PERFORMANCE CURVES
D B C A
24
20 P

S2
16 A
12
D

P
8 H F G E
P
4 L2
A
0 L1 L
10 20 30 40
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


97 21 3 25 10 47.5 9 50 50 24.5 35 30 98 12.5 10 4 15 M8
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 H H1 H2 D D1 D2 D3

SCHEMA DI MONTAGGIO / ASSEMBLY GUIDE

D B C A

H F G E

DESCRIZIONE DESCRIPTION

Deviatore rotativo a 9 vie 9-way, 8-position diverter


con 8 posizioni di lavoro. with eight working positions.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A150202.01.00 40 l/min 700 bar 1/4"G 1 kg
Pag. 15.02.02

Deviatore manuale 8 vie 2 posizioni


8-way 2-position manual diverter

90

5 6 7 8
L

1 2 3 4

POS. A POS. B H

D
B A

H1
1 5 1 6

2 6 2 5 D1 (n.2)
S L1 L1 L1 L2 L3
3 7 3 8

4 8 4 7
L5 L4

CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
25 8 7 6 5
20

S3
Dp1 Dp2
15 1 5 1 6
Dp2
S1

10 2 6 2 5
3 7 3 8
5 4 8 4 7
S2

Dp1
0 4 3 2 1
5 10 15 20 25 30
L6
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


119 30 17 11 ~147 4 136.5 60 44 8 ~150 35 17.5 18 M8
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 D D1

DESCRIZIONE DESCRIPTION

Deviatore rotativo a 8 vie 8-way diverter with 2 working


con 2 posizioni di lavoro. positions.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A150212.01.00 30 l/min 700 bar 1/4"G 2 kg


Pag. 15.03.01

Deviatore manuale a 3 vie


3-way manual diverter

CURVE CARATTERISTICHE
PERFORMANCE CURVES
A B
3/8"G
2
1.5
1
A P
0.5 P
L
0 10 20 30 40
3/4"G L1 L7
2 L2 L3 D
PRESSIONE / PRESSURE - p (bar)

1.5 L8
1

H4
A
0.5 P

H2
H3
0 10 20 30 40 50 60 70 80 90 100 B A

H1
Y

Y
1"G
2

H
1.5
1
A P
0.5 P L4 Y

0 20 40 60 80 100 120140160 180 L5 L6


1/2"G
2
1.5 NOTE:
1 La misura H riferita a quando
A
0.5 P la manopola a met corsa.

0 H is referred to the leve


10 20 30 40 50 60 in center vertical position.
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


124 60 17 26 30 30 14 60 3 125 60 40 16.25 14 11 1"G
124 60 14 32 30 30 14 60 3 118 60 40 16.25 9 11 3/4"G
124 60 14 32 30 30 15 50 3 108 60 28 13 9 11 1/2"G
124 60 17 26 30 30 15 50 3 107 60 28 13 9 8.5 3/8"G
L L1 L2 L3 L4 L5 L6 L7 L8 H H1 H2 H3 H4 D Y

DESCRIZIONE DESCRIPTION

Deviatore di usso manuale Manual ow diverter 3-way


a 3 vie con due posizioni di lavoro. with two working position.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A150303.01.00 40 l/min 500 bar 3/8"G 0.7 kg


A150403.01.00 60 l/min 500 bar 1/2"G 0.65 kg
A150603.01.00 100 l/min 500 bar 3/4"G 1.6 kg
A150803.01.00 180 l/min 500 bar 1"G 1.55 kg
Pag. 15.03.02

Deviatore manuale a 3 vie


3-way manual diverter

A B L

L1 L7
L2 L3 L8
P

H4

H2
H3
CURVE CARATTERISTICHE B A

H1
Y

Y
PERFORMANCE CURVES

3/4"G

H
2
P
PRESSIONE / PRESSURE - p (bar)

1.5 Y
L4
1
A
0.5 P
0 L5 L6
10 20 30 40 50 60 70 80 90100

1"G NOTE:
2
1.5 La misura h riferita a quando
1 la manopola a met corsa.
A
0.5 P H is referred to the leve
0 in center vertical position.
20 40 60 80 100120140160180
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


~210 80 18 44 40 47 12.5 ~60 4 ~148 80 40 23.75 14 11 1"G
~210 80 18 44 40 47 12.5 ~60 4 ~ 148 80 40 23.75 14 11 3/4"G
L L1 L2 L3 L4 L5 L6 L7 L8 H H1 H2 H3 H4 D Y

DESCRIZIONE DESCRIPTION

Deviatore di usso manuale Manual ow diverter 3-way


a 3 vie con due posizioni di lavoro. with two working position.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A150603.04.00 100 l/min 500 bar 3/4"G 2 kg


A150803.02.00 180 l/min 500 bar 1"G 1.95 kg
Pag. 15.04.01

Deviatore 3 vie, 2 posizioni con valvola limitatrice di pressione


3-way, 2-position manual diverter with relief

L1
L
S1 S
A L2 S2
P S3
1
P A

H5
T
H2 90
S4
H

H6
H3
B
H1

HEX 13

H4

D (n.2)
HEX4 2 B
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE L3
PERFORMANCE CURVES S5
L4
6
5
4
3 B
2 P POS. 1 2
A
1 P
FLUSSO P A PB
0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


60 113 27.5 26 ~112 30 22 15 9 4.5 63 86 30 36 35 13 15.5 100 6.5
L L1 L2 L3 L4 S S1 S2 S3 S4 S5 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Valvola intercettatrice ad Manual ow diverter 4-way.


azionamento manuale. La valvola Relief valve integrated
idonea anche a limitare on port B.
la pressione max sul ramo B.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A150404.01.00 50-300 bar 120 bar 165 bar/turn 60 l/min 400 bar 1/2"G 1.1 kg
Pag. 15.05.01
Blocco integrato con deviatore 3 vie, 2 posizioni, regolatore di portata
e limitatrice di pressione
3-way, 2-position integrated block with ow control and relief function

S1 S S2
L5
S6 S5 S3 L6
A S4
P
1

H2
P A

D2
H1

D1
H

60
D3 (n.2)

H3
D


B B T

H4
HEX 17
L4
2 HEX 5
PRESSIONE / PRESSURE - p (bar)

L2 L3
CURVE CARATTERISTICHE
PERFORMANCE CURVES L1 L
6
5
4
3 B
2 P A POS. 1 2
P
1 FLUSSO P A PB
0
20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


100 ~72 33 42 10 ~163 37 40 ~60 22 15 9 20 7.2 100 42 20 50 10 4.5 15.5 10 8.5
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 S4 S5 S6 H H1 H2 H3 H4 D D1 D2 D3

DESCRIZIONE DESCRIPTION

Valvola intercettatrice Manual ow diverter 4-way.


ad azionamento manuale Additional relief valve
con possibilit di dierenziare on diverter ow.
la pressione sul ramo deviato.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Ordinazione Codice Campo di Taratura Incremento Portata Pressione Dimensione Peso
Ordinazione Molle Taratura Standard per giro Massima Max Porte

Ordering Code Spring Ordering Pressure Standard Pressure Max Flow Max Port Size Weight
Code Range Setting Increase Pressure
A150604.01.00 902074 40-200 bar 120 bar 50 bar/turn 120 l/min 400 bar 3/4"G 2.8 kg
A150604.04.00 902075 100-320 bar 320 bar 75 bar/turn 120 l/min 400 bar 3/4"G 2.8 kg
Pag. 15.05.02
Blocco integrato con deviatore 4 vie, 2 posizioni, regolatore di portata
e limitatrice di pressione
4-way,2-position integrated block with ow control and relief function

3 M1 1
P A

H7
H6
B
2
T
L4
L3
M2
L2 L L1
1
M L5
H2 H H1
L6
H4 H3 H5 3
B

60

A
P A

S7
S6
D

S5

S9
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE

S4
D1 M1

S3
PERFORMANCE CURVES

S2
M
6

D2
S10
5

S8
HEX17

4 T HEX5
2
3 B T M2
B

S11
2 P A
1 P 16 L7
S1

0
20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


125 ~64 ~56 115 77.5 75 37 10 140 5 114 87 75.5 58 22 20 54.5 60 85 10 40 22 ~66.5 20 21 13 20 16 10 4.5 8.5
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 H H1 H2 H3 H4 H5 H6 H7 D D1 D2

DESCRIZIONE DESCRIPTION

La portata regolata sul ramo B The ow on port B can be


resta costante al variare regutated regardless
dalla pressione di lavoro. of the working pressure.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916005

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
P, A 3/4"G
A600050.22.00 40-200 bar 200 bar 50 bar/turn 120 l/min 400 bar B, T 1/2"G 5 kg
M, M1, M2 1/4"G
Pag. 15.06.01

Deviatore multifunzione 5 vie 4 posizioni


5-way, 4-positions multifunction diverter

POS. 1 2 3 4 5 6 7 8
BOCCA/PORT A B - - C D - -

VIEW X VIEW Y
1 45 2 2 45 1
CURVE CARATTERISTICHE
44
PERFORMANCE CURVES
R PRESSIONE / PRESSURE
A BC D
Dp (bar)

60

50
50

60
80
A R
P P P S

P S 0 10 20 30 40 50 60 6 5 5 50 6
PORTATA / FLOW - Q (l/min) 50 60
60

36,5 34 60
M1

M10
6,1
0n
A

6,1

A
A
50

S
.2

12
30
30

12
8
B
C Y
70

X
8
15

R P
37,5 D 10
65 25 93
49
83,5 79 26
278,5 Gruppo di Comando / Control Group
Codice / Code A (mm)
A160010.05.00 190
A160010.06.00 120

SCHEMA DI MONTAGGIO / ASSEMBLY GUIDE

B A

S A
B
R C
P
D
C D

DESCRIZIONE DESCRIPTION

Distributore doppio eetto Double-acting rotative


Corpo in acciaio / Steel body rotativo monoleva a 5 vie distributor with one lever,
con 4 posizioni di lavoro e 4 ve-way, four working
Attacchi / Port Size posizioni di arresto. Predisposto positions and four at rest.
A-B-C-D-R 3/8"G per doppio comando. Fitted for both sides use.
S-P 1/2"G
Codice di Ordinazione Utilizzatori Abilitati X Utilizzatori Abilitati Y Campo di Pressione
Max Peso
Ordering Code Portata
Working Port X Working Port Y Flow Max
Deviatore Rinvio Weight
Diverter Dual Control 1 2 5 6 1 2 5 6 Range Pressure
A150307.51.00 A160000.51.00 A B C D A B C D 5-45 l/min 200 bar 4.5 kg
A150307.52.00 A160000.52.00 A B - - - - C D 5-45 l/min 200 bar 4.5 kg
Pag. 15.06.02

Deviatore multifunzione 9 vie 8 posizioni


9-way, 8-positions multifunction diverter

POS. 1 2 3 4 5 6 7 8
BOCCA/PORT A B C D E F G H

CURVE CARATTERISTICHE
VIEW X VIEW Y
PERFORMANCE CURVES 45
44
PRESSIONE / PRESSURE
20 22,5
R 16
1 2 2 1
A BCDE FGH 12 A R
p (bar)

8 P P S 3 3
8 8
4 P

50
60
50

60
80
4 4 7
0 7
10 20 30 40 50 60
P S
6 5 5 50 6
PORTATA / FLOW - Q (l/min) 50
60
36,5 59 60 60

M10

M 10
30
A C 10
6,1
A

S
50

A
6,1

12

70
R B D
30

Y
X E G
70

12
8
P
F H 8
15

20
49 37,75
65,25 25 93,5
83,75 28,5 75,25 31
Gruppo di Comando / Control Group
311
Codice / Code A (mm)
A160010.00.00 190
A160010.01.00 136

SCHEMA DI MONTAGGIO / ASSEMBLY GUIDE

B A C D

A C
S
B D
E G
R
P
F H
E F H G

DESCRIZIONE DESCRIPTION

Distributore doppio eetto Double-acting rotative


Corpo in acciaio / Steel body rotativo monoleva a 9 vie e 8 distributor with one lever,
posizioni di lavoro. Predisposto nine-way and eight working
Attacchi / Port Size
per doppio comando. positions. Fitted for
A-B-C-D-E-F-G-H 3/8"G both sides use.
S-P 1/2"G
Codice di Ordinazione Utilizzatori Abilitati X Utilizzatori Abilitati Y Campo di Pressione Peso
Ordering Code Portata Max
Deviatore Working Port X Working Port Y Flow Max
Rinvio Weight
Diverter Dual Control 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Range Pressure
A150308.51.00 A160000.51.00 A B C D E F G H A B C D E F G H 5-45 l/min 300 bar 5.4 kg
A150308.52.00 A160000.52.00 A B C - - - - H - - - D E F G - 5-45 l/min 300 bar 5.4 kg
A150308.54.00 A160000.54.00 A - C D - F G H A B - - E F G H 5-45 l/min 300 bar 5.4 kg
Raccordi girevoli - Revolving connectors

Raccordi girevoli
Revolving connectors

Vengono utilizzati quando necessario Usually they are utilized to permit the
permettere ad una tubazione di ruotare hoses to spin free around their axles
liberamente attorno al proprio asse, an- even with high working pressure.
che con olio in pressione.
All connectors are made of steel and
Vengono realizzati con corpo in acciaio e have the following features:
hanno le seguenti caratteristiche: - very low pressure drops;
- ridotte perdite di carico in attraver- - low resistant torque even at high
samento; working pressure;
- ridotta coppia resistente anche con - high reliability.
alte pressioni di lavoro;
- elevata affidabilit. Max revolving speed = 10 RPM.

Velocit massima di rotazione: 10 RPM.


Pag. 17.01.01

Giunti rotanti
Revolving connectors

L1

L2 HEX HEX 1

M
G

G
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
2.5

1.5
1: 3/8"G
(1) (2) (3)
0.5 2: 1/2"G

0 3: 3/4"G
20 40 60 80 100 120
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


70 30 7 32 32 M24X1.5 3/8"G
78.5 32 8 41 36 M30X2 1/2"G
92.5 38 9 46 46 M36X2 3/4"G
L L1 L2 HEX HEX1 M G

DESCRIZIONE DESCRIPTION

Raccordo girevole a bassa coppia Revolving connector with low


di trascinamento anche resistant torque even at high
a pressioni elevate. working pressure.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte M Dimensione Porte G Peso

Ordering Code Max Flow Max Pressure Port Size M Port Size G Weight

A170302.01.00 45 l/min 350 bar M24x1.5 3/8"G 0.25 Kg


A170402.01.00 60 l/min 350 bar M30x2 1/2"G 0.4 Kg
A170602.01.01 120 l/min 350 bar M36x2 3/4"G 0.85 Kg
Pag. 17.02.01

Giunti rotanti
Revolving connectors

L1 L2 L3

T1 L4

24
M

D1
D

D2
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
HEX27 HEX27
2.5
2
1.5
1
0.5
0
8 16 24 32 40 48
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


~84.5 12 ~40 32.5 7 7 14.3 12 9 M18x1.5
L L1 L2 L3 L4 T1 D D1 D2 M

DESCRIZIONE DESCRIPTION

Raccordo girevole a bassa coppia Revolving connector


di trascinamento anche with low resistant torque even
a pressioni elevate. at high working pressure.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A173703.01.00 45 l/min 350 bar M18x1.5 0.25 kg


Pag. 17.03.01

Giunti rotanti
Revolving connectors

L3 L2 L1

L4 HEX
HEX1

D1
D2
D
24
M

M
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES

2.5 T1
2
1.5 (3)
1: M24x1.5
1 (2)
(1) 2: M30x2
0.5
3: M36x2
0 20 40 60 80 100 120 150

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


76 14 32 30 7 36 32 18.3 16 11 8.5 M24X1.5
84.5 16 36.5 32 8 46 41 22.9 20 14 10.5 M30X2
100 18 44 38 9 50 46 30.3 28 21 7.5 M36X2
L L1 L2 L3 L4 HEX HEX1 D D1 D2 T1 M

DESCRIZIONE DESCRIPTION

Raccordo girevole a bassa Revolving connector with low


coppia di trascinamento resistant torque even at high
anche a pressioni elevate. working pressure.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A174003.01.00 60 l/min 350 bar M24X1.5 0.36 Kg


A174403.01.00 100 l/min 350 bar M30X2 0.65 Kg
A174803.01.00 150 l/min 100 bar M36X2 0.85 Kg
Pag. 17.04.01

Raccordi girevoli
Revolving connectors

L2 L3

L1

HEX HEX1
HEX2

M
G

G
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
2.5

1.5
1: 3/8"G
(1) (2) (3) 2: 1/2"G
0.5
0 3: 3/4"G
20 40 60 80 100 120

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


110.4 30 75 34 32 32 30 M24X1.5 3/8"G
111.4 32 75 35 41 36 30 M30X2 1/2"G
143.6 38 96 46 46 46 46 M36X2 3/4"G
L L1 L2 L3 HEX HEX1 HEX2 M G

DESCRIZIONE DESCRIPTION

Raccordo girevole a bassa Revolving connector with low


coppia di trascinamento resistant torque even
anche a pressioni elevate. at high working pressure.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte M Dimensione Porte G Peso

Ordering Code Max Flow Max Pressure Port Size M Port Size G Weight

A170302.51.00 45 l/min 350 bar M24X1.5 3/8"G 0.7 kg


A170402.51.00 60 l/min 350 bar M30X2 1/2"G 0.8 kg
A170602.51.00 120 l/min 350 bar M36X2 3/4"G 0.95 kg
Pag. 17.05.01

Giunti rotanti
Revolving connectors

L
L1 L2
L3 L4

HEX HEX1
HEX2

D1
D2
D
M

M
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE
PERFORMANCE CURVES
2.5
2 T1
1.5 (3)
1 (1) (2)
0.5
0 20 40 60 80 100 120 150 1: M18x1.5
2: M20x2
PORTATA / FLOW - Q (l/min) 3: M42x2

Corpo in acciaio / Steel body


100 70.5 28 28 12 14.3 12 8 7 M18X1.5 27 27 24 0.3 Kg
100 70.5 28 28 12 14.3 12 8 7 M20X1.5 32 27 24 0.3 Kg
111 75 35 30 15 18.3 16 12 8.5 M24X1.5 32 32 30 0.5 Kg
139,5 92 46 34 16 22.9 20 16 10.5 M30X2 41 50 46 1.2 Kg
141,5 96 44 38 18 30.3 28 24 7.5 M36X2 46 50 46 1.2 Kg
144,5 97 46 39 20 33 30 25 13.5 M42X2 50 50 50 1.4 Kg
L L1 L2 L3 L4 D D1 D2 T1 M HEX HEX1 HEX2 PESO/WEIGHT

DESCRIZIONE DESCRIPTION

Raccordo girevole con bassa Revolving connector


coppia di trascinamento with low resistant torque
anche a pressioni elevate. at high working pressure.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A173703.51.00 60 l/min 350 bar M18X1.5 0.3 kg


A174003.52.00 60 l/min 350 bar M20X1.5 0.3 kg
A174003.53.00 60 l/min 350 bar M24X1.5 0.5 kg
A174403.51.00 100 l/min 350 bar M30X2 1.2 kg
A174803.51.00 150 l/min 300 bar M36X2 1.2 kg
A175203.51.00 200 l/min 300 bar M42X2 1.4 kg
Valvole di fine corsa - End stroke valves

Valvole di fine corsa


End stroke valves

Sono valvole a 2 vie e 2 posizioni di lavo- These are 2 ways-2 positions valves, both
ro, sia normalmente aperte che chiuse. normally closed and normally open.

Sono comandate da un elemento mec- They are controlled by a mechanical


canico che viene azionato quando lat- item that is activated when the actuator
tuatore raggiunge una posizione prede- reaches a defined position, blocking or
finita bloccando o consentendo il flusso allowing the flow.
dellolio.
Pag. 20.01.01

Valvola di ne corsa
End stroke valve

L4
P
L5

H1
C

H
C

HEX30

H2
)
.2
(n
P

D
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE L2 L3
PERFORMANCE CURVES S
3 L1
2.5 L
2
1.5
1 C
0.5 P P
C
0
10 20 30 40 50 60
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


60 21 44 8 115 10 30 60 16 26 8.5
L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Questa valvola "taglia" One-way smooth deceleration


l'immissione dell'olio al martinetto valve for nal displacement
quando viene premuta l'apposita of actuator. Free ow P to C
sfera di comando. La chiusura Controlled ow C to P.
totale (a richiesta anche parziale).

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight

A200402.01.00 60 l/min 450 bar 1/2"G 0.8 kg


Pag. 20.01.02

Valvola di ne corsa
End stroke valve

P L5 L L1

P
CURVE CARATTERISTICHE (n.
2)
PERFORMANCE CURVES

L2
3
2.5 L2 L3
2 L4
PRESSIONE / PRESSURE - p (bar)

1.5
1 C
0.5 P P
C
0 10 20 30 40 50 60 70
6
5
4 C
P
3 C P
2 P C
P
1 C

0 30 60 90 120 150 180 220


PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A200601.03.00 65 40 6 53 25 ~84.1 60 40 6.5 34.5
A200801.01.00 80 50 7.5 65 31 ~84.1 80 54 8.5 34.5
A201001.01.00 100 70 8 75 39 ~76.6 90 55 8.5 34.5
COD. L L1 L2 L3 L4 L5 H H1 D D1

DESCRIZIONE DESCRIPTION

Questa valvola "taglia" One-way smooth deceleration


l'immissione dell'olio al martinetto valve for nal displacement
quando viene premuta l'apposita of actuator. Free ow P to C
sfera di comando. La chiusura Controlled ow C to P.
totale (a richiesta anche parziale).

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A200601.03.00 70 l/min 350 bar 3/4"G 1.3 Kg
A200801.01.00 150 l/min 350 bar 1"G 2.4 Kg
A201001.01.00 220 l/min 350 bar 1-1/4"G 4.35 Kg
Pag. 20.02.02

Valvola di ne corsa
End stroke valve

B L2 L L1
L3 L4
L2 L5 S

D3
A

H1
D1
D2

H
D

B
F1
p (bar)

CURVE CARATTERISTICHE F
PERFORMANCE CURVES L6
9
8
PRESSIONE / PRESSURE -

7
6
5
4
3
2
1
0
10 20 30 40 50 60 70 80
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


80 5 10 55 7 45 25 35 50 35 18 13 35 12 M8 7
L L1 L2 L3 L4 L5 L6 S H H1 F F1 D D1 D2 D3

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Portata Massima Pressione Max Corsa Massima Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Max Stroke Port Size Weight

A200401.02.00 80 l/min 400 bar 7 mm 1/2"G 1 kg


Pag. 20.02.03

Valvola di ne corsa
End stroke valve

L7
B
L6
S3

L4 L5

L2 L3
S2
)
A (n.4

H
D
F

H3
H1
CURVE CARATTERISTICHE B
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES

H2
9 L1 S1
8
7 S
L
6
5
4
3
2
1
0
10 20 30 40 50 60 70 80
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


105 25 45 5 55 7 50 124.5 66 50 35 16 115 50 7.5 35 109 7
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 H H1 H2 H3 F D

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Portata Massima Pressione Max Corsa Massima Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Max Stroke Port Size Weight

A200401.05.00 80 l/min 400 bar 50 mm 1/2"G 1.3 kg


Pag. 20.02.04

Valvola di ne corsa
End stroke valve

L2 L L1
B S
L3 = =

B A'

=
H1

H
A' A

=
p (bar)

D1 (n.2)
CURVE CARATTERISTICHE

D (n.2)
L5 L4
PERFORMANCE CURVES
6
PRESSIONE / PRESSURE -

5
4
3
2
1

0 10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


102 2 13 61 29 10 40 60 44 13.5 8.5
L L1 L2 L3 L4 L5 S H H1 D D1

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Portata Massima Pressione Max Corsa Massima Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Max Stroke Port Size Weight
A, A' 1/2"G
A200301.01.00 60 l/min 400 bar 13 mm 1.6 kg
B 3/8"G
Pag. 20.02.05

Valvola di ne corsa
End stroke valve

L2 L L1

B L3
B

D (n.4)
=
H1

H
A

=
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES A
L4
3 S
L6 L5

0 15 30 45 60 75 90

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


90 5 12.5 57 37 15 65 45 90 60 9
L L1 L2 L3 L4 L5 L6 S H H1 D

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Corsa Massima Peso

Ordering Code Max Flow Max Pressure Port Size Max Stroke Weight

A200401.07.00 80 l/min 400 bar 1/2"G 12.5 mm 0.4 kg


Pag. 20.02.06

Valvola di ne corsa
End stroke valve

45 to 54 L L1
B
L4 L3 L2

L5 A B

=
H
H1
A

=
D1
HEX17 H3

H2
CURVE CARATTERISTICHE L6 L6 L7
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
D (n.3)
4

=
2

S
1

=
D2
0
10 20 30 40 50 60 70 80
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


99 4 20 40.5 21 7.5 29 13.5 40 60 42 7 13.9 8.5 16 M10
L L1 L2 L3 L4 L5 L6 L7 S H H1 H2 H3 D D1 D2

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Portata Massima Pressione Max Corsa Massima Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Max Stroke Port Size Weight

A200401.08.00 80 l/min 400 bar 13 mm 1/2"G 1.6 kg


Pag. 20.03.01

Valvola di ne corsa
End stroke valve

L4 L3
S

B M M1 HEX 36

H4
H2
H3
D (n.3)
A H

H1
CURVE CARATTERISTICHE A B
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

8
7
6
L2 L L1
A

5
4
B

3
2
1
0 20 40 60 80 100
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


100 29.5 14 82 9 40 122 70 32 60 9 8.5
L L1 L2 L3 L4 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso dolio da B verso A. the oil ow from A to B.
In posizione attivata il usso Free ow from B to A,
permesso solo da B verso A. when switched.

Codice Ordinazione Portata Massima Pressione Max Corsa Massima Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Max Stroke Port Size Weight
A, B 3/4"G
A200601.01.00 100 l/min 400 bar 13.5 mm 3.6 kg
M, M1 1/4"G
Pag. 20.03.02

Valvola di ne corsa
End stroke valve

=
S
A1 B1

=
F1 F F1

HEX32

A0 B0

H1

H
L3
CURVE CARATTERISTICHE

H2
PERFORMANCE CURVES L5 L5
PRESSIONE / PRESSURE - p (bar)

6 L2 L L1

5 L4
4 D (n2)
3

=
2
1
0

=
10 20 30 40 50 60

PORTATA / FLOW - Q (l/min) F3 F2 F3

Corpo in acciaio / Steel body


A200400.01.00 108 8.5 21 12 149.5 54 46 80 60 10 36 36 58 25 9
COD. L L1 L2 L3 L4 L5 S H H1 H2 F F1 F2 F3 D

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow
bidirezionale in posizione in switched position.
premuta.

Codice Ordinazione Pressione Max Portata Massima Corsa Max Dimensione Porte Peso

Ordering Code Max Pressure Max Flow Max Stroke Port Size Weight

A200400.01.00 350 bar 60 l/min 8 mm 1/2"G 2.8 kg


Pag. 20.03.03

Valvola di ne corsa
End stroke valve

A
F

CURVE CARATTERISTICHE
PERFORMANCE CURVES
PRESSIONE / PRESSURE - p (bar)

9
8
A
7
L

6
5
4
3
2
1
0 10 20 30 40 50 60 70 80

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A200401.09.00 157 57 25 50 125 5 20 70 7 35 8 23 24 8 40 8.2
COD. L L1 L2 S H H1 H2 H3 H4 H5 H6 F F1 F2 F3 D

DESCRIZIONE DESCRIPTION

La valvola blocca normalmente The valve normally locks


il usso nelle due direzioni the oil ow in both directions.
e permette il usso libero Free birectional ow in switched
bidirezionale in posizione position. For a lower opening
premuta. Per una minore force is recommended for use
forza d'apertura consigliato with ow from A to B.
utilizzarla col usso da A verso B.

Codice Ordinazione Pressione Max Portata Massima Corsa Massima Dimensione Porte Peso

Ordering Code Max Pressure Max Flow Max Stroke Port Size Weight

A200401.09.00 400 bar 80 l/min 7 mm 1/2"G 2.3 kg


Pag. 20.03.04

Valvola di ne corsa
End stroke valve

HEX27

L2
D1

C1

D1

L
S1

S
S2
C1

L1
max stroke
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES L3
6 H
5 = =
PRESSIONE / PRESSURE -

=
3

H1
2

=
1

0 10 20 30 40 50 60 D n.4
H2
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A200301.02.00 65 9 5.9 5 32.5 44.5 15 60 30 35 8.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 D

DESCRIZIONE DESCRIPTION

La valvola blocca The valve normally locks


normalmente il usso the oil ow in both directions.
nelle due direzioni e permette Free birectional ow
il usso libero bidirezionale in switched position.
in posizione premuta.

Codice Ordinazione Pressione Max Portata Massima Corsa Max Dimensione Porte Peso

Ordering Code Max Pressure Max Flow Max Stroke Port Size Weight

A200301.02.00 350 bar 40 l/min 5 mm 3/8"G 0.8 kg


Prodotti speciali - Special products

Prodotti speciali
Special products

Questa sezione raggruppa una ampia This section offers a large range of
gamma di valvole tipo: valves for different applications:

- pulsanti 2/2; - 2 ways-2 positions switches;


- pulsanti 3/2; - 3 ways-2 positions switches;
- valvole di messa a scarico per sistemi - unloading valves for emergency
di emergenza; systems;
- valvole di esclusione per alta-bassa - high-low pressure exclusion valves;
pressione; - rotation control valves
- valvole di controllo rotazione for special applications;
per applicazioni speciali; - integrated block for garbage
- blocchi integrati per auto compattatori; compactors;
- valvole di messa a scarico pilotate; - pilot operated unloading valves;
- valvole di sequenza per limitatore - sequence valves for load
di carico; control systems;
- blocco pilotato per limitatore di carico; - integrated block for load
- gruppo integrato per il blocco control systems;
delle spole distributori; - integrated block with kick out pistons;
- valvole di scambio per circuiti - purge valve for closed loop
idrostatici; hydrostatic systems;
- valvole anticavitazione. - anti-cavitation valve.
Pag. 30.01.01

Pulsante 3 vie 2 posizione


3 ways 2 positions switch

H2 corsa
S3 H3 H3

1,5x45
R4

S1
U

H1

1x45

D1

D
F
P T
L3

H
L1

S
L

F1
P
L2

T 1x45
F2
L5 S2
L4

F3

Corpo in acciaio / Steel body


A300102.02.00 79.4 74.5 31 43.5 4.9 10 63 11.5 30 20 29 25 3.2 4 36.5 38 10 20 8 4.5
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 F F1 F2 F3 D D1

DESCRIZIONE DESCRIPTION

Pulsante 3/2 3 ways,


a comando manuale. 2 positions switch.

Codice Ordinazione Contropressione Portata Massima Pressione Max Dimensione Porte Peso
Max in T

Ordering Code Max Backpressure Max Flow Max Pressure Port Size Weight
in T
A300102.02.00 10 bar 5 l/min 400 bar 1/8"G 0.4 kg
Pag. 30.01.02

Pulsante 3 vie 2 posizione


3 ways 2 positions switch

H2 corsa
S3 H3 H3

1,5x45
R4
U

S1
H1

1x45

D1
P T

D
F
L3

H
L1

S
L

F1
P
L2

1x45
T F2
L5 S2
L4

F3

Corpo in acciaio / Steel body


A300102.01.00 79.4 74.5 31 43.5 4.9 10 63 11.5 30 20 29 25 3.2 4 36.5 38 10 20 8 4.5
COD. L L1 L2 L3 L4 L5 S S1 S2 S3 H H1 H2 H3 F F1 F2 F3 D D1

DESCRIZIONE DESCRIPTION

Pulsante 3/2 3 ways,


a comando manuale. 2 positions switch.

Codice Ordinazione Contropressione Portata Massima Pressione Max Dimensione Porte Peso
Max in T

Ordering Code Max Backpressure Max Flow Max Pressure Port Size Weight
in T
A300102.01.00 10 bar 5 l/min 400 bar 1/8"G 0.4 kg
Pag. 60.01.01

Pulsante 3 vie 2 posizioni


3 way, 2 position switch

S
D3
U

H
D

L6
P S

L5
D1

D2

L4
L3
L

D4
L2

U P
L1

Corpo in alluminio / Aluminium body

98 25 36 12 9 28 9 42 40 40 30 24 55 M5
L L1 L2 L3 L4 L5 L6 S H D D1 D2 D3 D4

DESCRIZIONE DESCRIPTION

Pulsante 3/2 a comando 3 ways, 2 position switch


manuale

Codice Ordinazione Portata Massima Pressione di Lavoro Contropressione Dimensione Porte Peso
Massima in S

Ordering Code Max Flow Working Pressure Max Backpressure In Port Size Weight
S
A600000.40.00 10 l/min 350 bar 5 bar 1/8"G 0.6 kg
Pag. 60.02.01

Pulsante 3 vie 2 posizioni


3 way, 2 position switch

D3

S
H
D

S U

L6
L5
D1

D2

L4
L3
L

L2

D4

P U
L1

Corpo in alluminio / Aluminium body


98 25 36 12 9 28 9 42 40 40 30 24 55 M5
L L1 L2 L3 L4 L5 L6 S H D D1 D2 D3 D4

DESCRIZIONE DESCRIPTION

Pulsante 3/2 a comando 3 ways, 2 positions switch


manuale

Codice Ordinazione Portata Massima Pressione di Lavoro Contropressione Dimensione Porte Peso
Massima in S

Ordering Code Max Flow Working Pressure Max Backpressure Port Size Weight
in S
A600000.41.00 10 l/min 350 bar 5 bar 1/8"G 0.6 kg
Pag. 60.03.01

Pulsante 2 vie 2 posizioni


2 way, 2 position switch

H1
H
P

S
D1

T D

HEX 36
L4
L
L1

P T
L3
L6
L5
L2

Corpo in acciaio / Steel body


76 52 2.8 24 9 10 12 45 50 30 24.6 M30x1.5
L L1 L2 L3 L4 L5 L6 S H H1 D D1

DESCRIZIONE DESCRIPTION

Pulsante 2/2 a comando 2 way, 2 position switces


manuale

Codice Ordinazione Portata Massima Pressione di Lavoro Contropressione Dimensione Porte Peso
Massima in T

Ordering Code Max Flow Working Pressure Max Backpressure Port Size Weight
in T
A600000.42.00 5 l/min 350 bar 5 bar 1/4"G 0.5 kg
Pag. 60.04.01

Valvola di messa a scarico per sistema demergenza


Unloading valve for emergency system

S
S
HEX 22 = =

H1
D (n.2)
U S
D H2

H
CURVE CARATTERISTICHE
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
9
7.5
H3

6
4.5 S D
L3 L2
3 D
1.5 L1 L

0 10 20 30 40 50 60

PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


50 10 22 10 30 60 25 45 7.5 6,5
L L1 L2 L3 S H H1 H2 H3 D

SCHEMA IDRAULICO CON VALVOLA DOPPIA


HYDRAULIC DIAGRAM WITH TWO VALVES

A60000041.00 P S
U

S U D
A60000060.00

DESCRIZIONE DESCRIPTION

Valvola di messa a scarico Pilot operated normally closed


normalmente chiusa con poppet type unloading valve.
otturatore a cono pilotato.

Codice Ordinazione Portata Massima Pressione di Lavoro Dimensione Porte Peso

Ordering Code Max Flow Working Pressure Port Size Weight


D, S 1/2"G
A600000.60.00 60 l/min 350 bar 0.8 kg
U 1/8"G
Pag. 60.04.01A

Valvola di messa a scarico per sistema demergenza


Unloading valve for emergency system

D L
L1

S1
S D

CURVE CARATTERISTICHE
S
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
L2 = =
8 U
7 H2
6

H3
D

D (n.2)
S
4
S

H1
H

3
2
S
1
0
15 30 45 60 75 90
D
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body

70 44 10 40 20 75 55 10 34 8.5
L L1 L2 S S1 H H1 H2 H3 D

SCHEMA IDRAULICO CON VALVOLA DOPPIA


HYDRAULIC DIAGRAM WITH TWO VALVES

A60000041.00 P D
U

S U S
A60000062.00

DESCRIZIONE DESCRIPTION

Valvola di messa a scarico Pilot operated normally closed


normalmente chiusa con poppet type unloading valve.
otturatore a cono pilotato.

Codice Ordinazione Portata Massima Pressione di Lavoro Dimensione Porte Peso

Ordering Code Max Flow Working Pressure Port Size Weight


S, D 3/4"G
A600000.62.00 80 l/min 350 bar 1.3 kg
U 1/4"G
Pag. 60.04.01B

Valvola di messa a scarico per sistema d'emergenza


Unloading valve for emergency system

D
(n
2)
D

F1
U

H2
H
F

H1
S

CURVE CARATTERISTICHE
L1 S2
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
8 L2
7 L
6
5 D
L3
4 S
3
2
S1

1
0
S

25 50 75 100 125 150


PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A600000.63.00 80 30 70 30 50 25 25 80 45 95 55 10 8.5
COD. L L1 L2 L3 S S1 S2 H H1 H2 F F1 D

DESCRIZIONE DESCRIPTION

Valvola di messa a scarico Pilot operated normally


normalmente chiusa closed poppet type
con otturatore a cono pilotato. unloading valve.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


D, S 1"G
A600000.63.00 150 l/min 350 bar 0.66 kg
U 1/4"G
Pag. 60.07.01

Blocco integrato per compattatori di riuti


Integrated block for garbage compactors

T2 32,5 T2
1

50
1
A1

3 M1

35
4 M1

83
4 3 2
6 2 5 6

187
5 B2 A B
A2 B2
M10X20 B2

71,5

49,5
71,5

67
A2
49,5

26,5
26,5
39
T3 T A2
12

12
T1
M10X20 23 45 27 30
12 73 72
49 82 49 120
133
6 25

48
PALA CARRELLO
PACKER BLADE CARRIER
B2
3 B2
B1
A2

158
A1 B1 T2 A2
M1 2
6 (280 bar)
4 A1 4

80
5

30
5 (300 bar)
A2 A2
T3 A T B
B2 3 (350 bar) B2 32,5
2 92 158 92

T3 T2
T1
1 (175 bar)

T A B

Corpo in alluminio / Aluminium body


DESCRIZIONE DESCRIPTION

Blocco integrato per il comando Multifunction integrated block


e il controllo dei cilindri dei for the control of the cylinders
compattatori di riuti. of garbage compactors.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
1 - 0-200 bar 175 bar 130 bar/turn A, A1, A2, B,
B1, T 3/4"G
3 8:1 50-350 bar 350 bar 80 bar/turn
A600050.29.00 150 l/min 400 bar 14.5 kg
5 16:1 50-350 bar 300 bar 80 bar/turn B2, T1 1/2"G
6 - 100-350 bar 280 bar 110 bar/turn M1, T2, T3 1/4"G
Pag. 60.07.02

Valvola di messa a scarico pilotata con valvola di massima pressione


Pilot operated unloading valve with pressure relief valve

L2 L L1
L3
HEX5
A
P A HEX17

H1
Pil
A B B
B Pil T
T

H2
HEX4
H3

H
T

D (n.2)
HEX13

H5
P
P
H4

S3
L6
S2
S1 S L5 L4

Corpo in alluminio / Aluminium body


100 ~22 11 51 80 10 10 70 5 43 21 80 ~51 40 33 24 46.5 6.5
L L1 L2 L3 L4 L5 L6 S S1 S2 S3 H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

La valvola permette The valve unload the line P


di mettere a scarico la linea once a preset pressure value
"P" al raggiungimento is reached. The valve A
di un reimpostato valore alows an adjustable
di pressione. La valvola "A" back pressure on the P line.
mantiene una contropressione Normally used in garbage
regolabile sul ramo "P". compactor system.
Generalmente montata
su circuiti per auto compattatori.

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
A 40-150 bar 40 bar 25 bar/turn P 1/2"G
A600000.67.00 30 l/min 400 bar T 3/8"G 1.8 kg
B 50-210 bar 180 bar 36 bar/turn Pil 1/4"G
Pag. 60.08.01

Valvola di sequenza per limitatori di carico


Sequence valve for load limiting system

L1 L

T P

=
S
=
D (n.2)
S

L3 L2

HEX19
HEX17 T P

H2

H
H1
S
L4 L5

Corpo in alluminio / Aluminium body


67.5 69 24 28.5 40.5 12 40 59 32 18 6.5
L L1 L2 L3 L4 L5 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza per limitatore Sequence valve for load control


di carico. Caratterizzata systems. Negligible leakage
da tralamento trascurabile and very low hysteresis.
e isteresi molto limitata.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A600011.05.00 80-300 bar 280 bar 25 bar/turn 8 l/min 350 bar 1/4"G 0.85 kg
Pag. 60.08.02

Valvola di sequenza per limitatori di carico


Sequence valve for load limiting system

L2 L1 L

T P L3 L4

=
S
=
D (n.2)
0.3

S1 S L5 L6
HEX17 HEX19
T P

H2
H1
H
S1 S
L7
L8

Corpo in alluminio / Aluminium body


67.5 69 ~38 40.5 12 28.5 24 19 56 40 80 32 18 6.5
L L1 L2 L3 L4 L5 L6 L7 L8 S H H1 H2 D

DESCRIZIONE DESCRIPTION

Valvola di sequenza per limitatore Sequence valve for load control


di carico. Caratterizzata systems. Negligible leakage
da tralamento trascurabile and very low hysteresis.
e isteresi molto limitata.

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Peso


Taratura Standard per giro Massima Max Porte

Ordering Code Pressure Standard Pressure Max Flow Max Pressure Port Size Weight
Range Setting Increase
A600011.11.00 80-300 bar 280 bar 25 bar/turn 8 l/min 350 bar 1/4"G 0.95 kg
Pag. 60.09.01

Blocco pilotato per limitatore di carico


Pilot operated block for load limiting systems

HEX19
1 2 3 4

1 2 3 4

H1
H4

H2
S S

H3

H
P

H2
P

D (n.2)
=
S
=

L4 L5
L3
L2
L1
L

Corpo in alluminio / Aluminium body


110 85 60 35 10 10 25 60 33 25 29 8 6.5
L L1 L2 L3 L4 L5 S H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Blocco integrato con 4 valvole Integrated block with 4 pilot


di blocco per limitatori di carico. operated check valves
for load control systems.

Codice Ordinazione Rapporto di Pressione di Inizio Portata Pressione Dimensione Peso


Pilotaggio Apertura Massima Max Porte

Ordering Code Pilot Ratio Cracking Pressure Max Flow Max Pressure Port Size Weight

A600014.06.00 5:1 25 bar 20 l/min 350 bar 1/4"G 0.5 kg


Pag. 60.10.01

Blocco integrato con pistoni


Integrated block with kick out pistons

H1 H H2
S
= = H4 H3

L1

L4
L2
L3

L2

L5
D (n.2)
S
H5 HEX24
S

Corpo in alluminio / Aluminium body


A600014.11.00 20 40 125 40 78 30 70 24 24 50 10 35 6.5
A600014.10.00 16 32 105 32 66.5 30 70 24 24 50 10 35 6.5
COD. L1 L2 L3 L4 L5 S H H1 H2 H3 H4 H5 D

DESCRIZIONE DESCRIPTION

Blocco integrato con pistoncini Integrated block with kick out


comandati idraulicamente per pistons to lock the levers
bloccare le leve del distributore. of directional valve.

Codice Ordinazione Interasse tra le Leve Pressione Max Dimensione Porte Peso

Ordering Code Distance between the levers Max Pressure Port Size Weight

A600014.10.00 32 mm 1/4"G 0.8 kg


350 bar
A600014.11.00 40 mm 1/4"G 1.0 kg
Pag. 60.11.01

Valvola limitatrice di momento


Moment limiting valve

36 24 41 20

DISCESA SECONDARIO

T2 P2
0.4 RS

RIENTRO SFILO
E S2 0.3

109
P S1
T P1
0.3
T1

27
DP

US
SS

21,5
T
76,5

80
46,5

46,5
33
RS

45
P

16
12

12
9 52
24 24 13 5,5 N.8 FORI
104
N.8 VITI TCEI UNI 5931 M5x135 -8.8 ZINCATE 89
N.8 ZINC COATED SCREWS UNI 5931 M5x135 -8.8 61
20

9
24

N.2 VITI SPECIALI

80
N.2 SPECIAL SCREWS
36

24
8
= = 17
24 52
NOTA:
Nella confezione sono incluse
anche le viti di ssaggio e le viti
di attacco alle leve del distributore.
The screws are inside the valve package.
DESCRIZIONE DESCRIPTION

Valvola limitatrice di momento Moment limiter valve directly


da collegare direttamente mounted on the directional valve.
al distributore. Questa valvola This valve, when the machine
quando si raggiunge una situazione is in a dangerous situation,
di pericolo blocca meccanicamente blocks mechanically the levers
le leve del distributore. of the directional valve.
Sono disponibili vari modelli Several models are available
a seconda del tipo di distributore, depending upon the kind
contattare l'ucio tecnico. of the directional valve, please
contact the technical dept.

Corpo in alluminio / Aluminium body

Codice Ordinazione Campo di Taratura Incremento Pressione Max Dimensione Peso


Taratura Standard per giro Porte

Ordering Code Pressure Standard Pressure Max Pressure Port Size Weight
Range Setting Increase

A600012.10.00 80-300 bar 280 bar 25 bar/turn 350 bar 1/4"G 2.7 kg
Pag. 60.11.02

Blocco integrato limitatore di momento


Load integrating integrated block

SIMULATORE
RUBINETTO
DI CARICO
DI EMERGENZA
(NORM.CHIUSO)
(NORM.APERTO)
P ~34 99 ~27
T

T
M

54
F
SEGNALE
DI PERICOLO

80,5 54
DP RS 49
RIENTRO SFILI

SEGNALE DA INIBIRE M
(PER ES. : DISCESA
F
DEL PRIMARIO)

160
DP
143

124,5
8,5

114
69,5

69,5

71
10
P

37
27

RS 22

21
21
69 80 10 54
22 99 38 69

DESCRIZIONE DESCRIPTION

Valvola limitatrice di momento. Load limiting valve. When the


Al raggiungimento della pressione pressure in the circuit reaches
di taratura manda a scarico the maximum level admitted
la linea P (valvola di messa unload the ow of the port P
a scarico pilotata del distributore). (normally the piloted unloading
valve of the directional valve).

Corpo in alluminio / Aluminium body

Codice Campo di Taratura Incremento Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per giro Max

Ordering Code Pressure Range Standard Setting Pressure Max Pressure Port Size Weight
Increase
A600014.36.00 100-380 bar 200 bar 83 bar/turn 450 bar 1/4"G 3.9 kg
Pag. 60.11.03

Blocco integrato limitatore di momento


Load limiting integrated block

P T
Pil
M
HEX17 F2 F3

RS

S2
S
T
M

S1
I Pil

S1

S4

S3
I
L4
HEX19 L3
RS P
L2 L L1

D (n2) RS

H1
I P

=
H
=
T

Corpo in alluminio / Aluminium body


A600014.04.00 120 26.5 29.7 106 95 88 16.5 79 14 33.5 40 27 40 36 56 40 8.5 M16x1.5 1/8G
COD. L L1 L2 L3 L4 S S1 S2 S3 S4 H H1 F F1 F2 F3 D I M

DESCRIZIONE DESCRIPTION

Valvola limitatrice di momento. Load limiting valve.


Al raggiungimento When the pressure in the circuit
della pressione di taratura reaches the maximum level
manda a scarico la linea admitted unload the ow
P (valvola di messa a scarico of the port P (normally
pilotata del distributore). the piloted unloading valve
of the directional valve).

Codice Ordinazione Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Taratura Standard per giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
P-T 1/2"G
A600014.04.00 100-350 bar 250 bar 83 bar/turn 60 l/min 350 bar 1.7 kg
Pil-RS 1/4"G
Pag. 60.12.01

Blocco intergrato distributore e valvola rigenerativa per spaccalegna


Integrated block with spool valve and regenerative system for wood splitter

109
27 24 18 60 40
3,5
10

16
2

10

43
B1 T

33
32

109
45,5

24
33,5

A1

19 10
30
5 20,5

24

9
10
25,5 53,5 8,5 N.2 FORI 37 40
40 50 ~36

97 150 ~42
29 43,5 67,5

14
A1 B1
M2 M3
2

48
1 250 bar
40

29
25

22 47 25,5
0.8
3 4
1 OVERCENTRE VALVE 2,5

250 bar (CLOSED CENTRE VERSION)


M1 2 PILOT OPERATED
P T CHECK VALVE
(PILOTED TO CLOSE)

M
3 DIRECTIONAL VALVE
4 RELIEF VALVE

DESCRIZIONE DESCRIPTION

La valvola permette la discesa The valve allows high speed


veloce dello stelo cilindrico of the cilinder, thanks to the
nella corsa a vuoto, grazie regenerative system during
al circuito rigenerativo integrato the free stroke and the full power
e la piena potenza della macchina during the working stroke,
durante la fase di lavoro when the regenerative function
in cui la fase rigenerativa viene is automatically taken o.
esclusa automaticamente.

Corpo in alluminio/Aluminium body

Codice Rapporo di Campo di Taratura Taratura Incremento Portata Pressione Dimensione Peso
Ordinazione Pilotaggio Standard per Giro Massima Max Porte
Ordering Pilot Ratio Pressure Range Standard Pressure Max Max Port Size Weight
Code Setting Increase Flow Pressure
4:1 1 100-350 bar 250 bar 108 bar/turn

2.9:1 2 - - -
A600050.27.00 100 l/min 300 bar 3/4"G 5.8 kg
- 3 - - -
- 4 50-300 bar 250 bar 65 bar/turn
Pag. 60.13.01

Valvola regolazione pressione freno rimorchio


Valve for trailor breaking system

99 max.

50
U E

V H L

106
U

44
E
33

17
6

30
60
10 43
20

6,5 N.2

60
93

DESCRIZIONE DESCRIPTION

La valvola permette di regolare The valve allows to set the


manualmente la pressione trailer breaking pressure
di frenatura del rimorchio to 3 dierent values in
a tre diversi valori a seconda accordance to the lever position.
della posizione della leva.

Corpo in alluminio / Aluminium body

Codice Ordinazione Pressione di Commutazione Pressione Max Dimensione Porte Peso

Ordering Code Switching Pressure Max Pressure Port Size Weight


POS L 50 bar
B600000.49.00 POS H 80 bar 210 bar M18x1.5 1 kg
POS V 110 bar
Pag. 60.14.01

Valvola di scambio automatico


Automatic directional valve

A B L3 L2
L4
L5

S2
S5
L6
1 2
P

S4
A B

S6
R R

S3
S7

S1
S
T
O-RING

P T
L6 L7
riarmo manuale 5
CURVE CARATTERISTICHE manual reactivation 5

H1
PRESSIONE / PRESSURE - p (bar)

PERFORMANCE CURVES
12
10
R R
8
T

B
A-

H
B

4
A-

2
0
10 20 30 40
PORTATA / FLOW - Q (l/min) D (n.4)
L1 L L1
Corpo in acciaio / Steel body
80 5.5 21 40.5 27.8 19 10.3 29.5 21 45 32.5 6.25 26.6 16.2 5.85 0.75 31 57 21.5 5.5 OR 108 8.73x1.78
L L1 L2 L3 L4 L5 L6 L7 L8 S S1 S2 S3 S4 S5 S6 S7 H H1 D O-RING

DESCRIZIONE DESCRIPTION
E una valvola direzionale che genera It is a directional valve which
un continuo movimento reciproco generates continuous reciprocating
i un attuatore a doppio eetto, senza motion of a double acting actuator,
bisogno di controlli dallesterno. with no need of external controls.
Il usso mandato alla bocca A (o B), It delivers the pump ow to port A
e scaricato a serbatoio dalla bocca B (or B), and opens to tank port B
(o A) no al momento in cui la (or A), until A (or B) pressure increases
pressione aumenta e apre la relativa and opens the related small relief
valvola di massima. Lolio scaricato valve; the relieved oil shifts the
dalla valvola di massima cambia la position of the 3/2 pilot spool,
posizione della spola di pilotaggio 3/2 and, consequently, the line
e di conseguenza la pressione della pressure P pilots the main 4/2 spool
linea P pilota la spola principale 4/2 to the opposite position; the oil ow
alla posizione opposta; il usso di olio is diverted to the other outlet
viene deviato allaltra bocca di uscita B port B (or A) and the port
(o A) e la bocca precedentemente previously supplied becomes open
in mandata diventa bocca di scarico; to tank: the motion is reversed.
il movimento invertito. Shifting takes place whenever
Lo scambio avviene tutte le volte the load increases up to
che il carico aumenta no al the selected pressure relief setting,
raggiungimento della pressione and the cycle is repeated
di taratura della valvola di massima, automatically and indenitely
e il ciclo si ripete automaticamente as long as the pump continues to run.
ntantoch la pompa in azione.

Codice Campo di Taratura Incremento Pressione Max Dimensione Porte Peso


Ordinazione Taratura Standard per Giro

Ordering Code Pressure Range Standard Setting Pressure Max Pressure Port Size Weight
Increase
A602301.01.00 90-350 bar 210 bar 120 bar/turn 350 bar CETOP 3 1.5 kg
Pag. 60.14.02

Valvola di scambio automatico


Automatic directional valve

L3 L4
L5
L6
L7
L8
L9
A B

TA TB

S5
S
B

S4
TA P TB A

S3
P
L2 L L1

S1
S2
O-RING
PRESSIONE / PRESSURE - p (bar)

CURVE CARATTERISTICHE Dispositivo di blocco hex5


PERFORMANCE CURVES Locking screw for pressure setting hex5
25
20

H2
A

H1
15
P
10

H
5
0
10 20 30 40 50 60 70 80 D (n.4)
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


98 20 57 54 22 50.8 37.3 27 16.7 3.2 46 9.5 39.7 24.6 13.5 65 36 23.5 6.5 OR 2050 12,42x1.78
L L1 L2 L3 L4 L5 L6 L7 L8 L9 S S1 S2 S3 S4 H H1 H2 D O-RING

DESCRIZIONE DESCRIPTION

E una valvola direzionale It is a directional valve which


che genera un continuo movimento generates continuous reciprocating
reciproco di un attuatore a doppio motion of a double acting actuator,
eetto, senza bisogno di controlli with no need of external controls.
dallesterno. Quando il usso passa in P, It delivers the pump ow to port A
la spola di controllo apre ulteriormente (or B), and opens to tank port B (or A),
il passaggio da P ad A (e B a scarico); until A (or B) pressure increases
la dierenza di pressione tra P e A and opens the related small relief
utilizzata per mantenere la spola valve; the relieved oil shifts
in questa posizione pi aperta. the position of the 3/2 pilot spool,
Quando il carico diventa eccessivo, and, consequently, the line pressure
o a ne corsa, la valvola di massima P pilots the main 4/2 spool
del sistema si apre, lolio deviato to the opposite position; the oil ow
a scarico, il usso da P ad A bloccato is diverted to the other outlet port B
e la dierenza di pressione si annulla.; (or A) and the port previously supplied
ora lazione combinata di molla becomes open to tank: the motion
e pressione statica nella linea A spinge is reversed. Shifting takes place
indietro la spola facendola traslare whenever the load increases up
nellaltra posizione. Questo apre to the selected pressure relief
il passaggio tra P e B, che mantiene setting and the cycle is repeated
la spola nella nuova posizione. Quando la automatically and indenitely
valvola di massima del sistema si apre di as long as the pump continues to run.
nuovo il usso si blocca, la dierenza di
pressione si annulla, e la spola torna nella
posizione normale con il passaggio tra
P e A aperto; comincia un nuovo ciclo.

Codice Ordinazione Portata Massima Pressione Max Dimensione Porte Peso

Ordering Code Max Flow Max Pressure Port Size Weight


A602401.01.00 80 l/min 210 bar CETOP 5 3 kg
Pag. 90.01.01

Valvola di scambio per circuiti idrostatici


Purge valve for closed loop hydrostatic system

L1 L L1
U1 U2 L7
L2 L3
L8
= =
L9

Y
Y
T

Y
D1 D2

M M
H6
H5

H3
D
H4

H
H2

H1
D1-D2 U1-U2 L6
D2 D1 L6
L10
D1 L4 L5 L5 L4

Corpo in acciaio / Steel body


113.5 13.25 47.5 33 7 40.5 20.25 49 37 20 10 18.2 8.5 17.6 75 52 78 90 13 8.5 1/4"G 1/2"G
142 - 47.5 47.25 8.1 50.8 25.4 59 48 23 12 23.8 9.5 21.4 85 63 86 100 19 10.5 1/4"G 3/4"G
160 - 47.5 56.25 9.4 57.2 28.6 59 47 23 14 27.8 11 24.9 92 71 94 108 25 12.5 1/4"G 1"G
L L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 H H1 H2 H3 H4 H5 H6 D D1 Y M

DESCRIZIONE DESCRIPTION

In una trasmissione a circuito In a closed circuit transmission,


chiuso, la valvola di ussaggio the ushing valve removes part
rimuove parte del uido of the uid in the main circuit.
nel circuito principale. Il uido The uid removed is replaced
rimosso viene sostituito continuously from ltrate
di continuo dal uido rareddato and cooled uid coming from
e ltrato proveniente dalla the low pressure charge pump
pompa di carica a bassa on the main pump.
pressione sulla pompa principale.

Codice Portata di Pressione di Pressione di Filtraggio Strozzatura Pressione Peso


Ordinazione Flussaggio Flussaggio Lavoro Raccomandato Max

Ordering Code Fluxing Fluxing Working Racomanded Contraction Max Weight


Flow Pressure Pressure Filtering Pressure
A900400.01.00 6-8 l/min 25-30 bar 320 bar 50 m 1.8 mm 350 bar 3.4 kg
A900600.01.00 8-10 l/min 25-30 bar 320 bar 50 m 2.0 mm 350 bar 5.3 kg
A900800.01.00 10-12 l/min 25-30 bar 320 bar 50 m 2.1 mm 350 bar 6 kg
Pag. 90.01.02

Valvola anticavitazione
Anticavitation valve

U1 U2

0.5 Bar

L L1
S

D1 D2
H1
U1 U2

CURVE CARATTERISTICHE
PERFORMANCE CURVES
H

7.5

6
H2

4.5

3 D1 D2
HEX41
1.5 L2 L3

0
30 60 90 120 150

Corpo in acciaio / Steel body


A900600.02.00 117 4.8 53 32 40 45 14 25
COD. L L1 L2 L3 S H H1 H2

DESCRIZIONE DESCRIPTION

Flangiabile su motori SUNFAB. Flangeable on SUNFAB motors.

Codice Ordinazione Pressione di Lavoro Pressione Max Dimensione Porte Peso

Ordering Code Working Pressure Max Pressure Port Size Weight

A900600.02.00 320 bar 350 bar 3/4"G 2 kg


Pag. 90.01.03

Valvola anticavitazione angiata


Anticavitation angeable valve

U1 U2

0.5 Bar 0.5 Bar


L2 L3
S

H1
L4
V2 V1
H3

D1 D2

H
CURVE CARATTERISTICHE
PERFORMANCE CURVES U1-U2 V1-V2
H2

7.5

.8
Dn
6

4.5

3 L1 L L1

1.5

0
30 60 90 120 150

Corpo in acciaio / Steel body


A908200.01.00 142 6 75 33.5 50.8 54 85 4.5 59 23.8 10.5
COD. L L1 L2 L3 L4 S H H1 H2 H3 D

DESCRIZIONE DESCRIPTION

Valvola anticavitazione Anticavitation valve


con attacco 3/4" SAE 6000. with 3/4" SAE 6000 ports.

Codice Ordinazione Pressione di Lavoro Pressione Max Dimensione Porte Peso

Ordering Code Working Pressure Max Pressure Port Size Weight

A908200.01.00 320 bar 350 bar 3/4"G 3.9 kg


Pag. 90.01.04

Valvola anticavitazione angiata


Anticavitation angeable valve

U1 U2
L1 L L1
L4 D (n.8)
0.5 Bar 0.5 Bar

H1

H
D1 D2

CURVE CARATTERISTICHE
PERFORMANCE CURVES L2 L3 HEX 42
PRESSIONE / PRESSURE - p (bar)

3
2.5
D1 D2
2
1.5
1

S
0.5
0
30 60 90 120 150 180
U1 U2
PORTATA / FLOW - Q (l/min)

Corpo in acciaio / Steel body


A908400.01.00 143 8.8 88 27.5 27.8 64 86 57.2 12.5
COD. L L1 L2 L3 L4 S H H1 D

DESCRIZIONE DESCRIPTION

Valvola anticavitazione Anticavitation valve


con attacco 1" SAE 6000. with 1" SAE 6000 ports.

Codice Ordinazione Pressione di Lavoro Pressione Max Dimensione Porte Peso

Ordering Code Working Pressure Max Pressure Port Size Weight

A908400.01.00 320 bar 350 bar 1"G 4.3 kg


Pag. 90.01.05

Valvola anticavitazione angiata


Anticavitation angeable valve

L1 L L1
= =
U1 U2 F1

0.5 Bar 0.5 Bar

L4
L2
D

L3
V1 D V2

U1 U2
O-RING
H2
CURVE CARATTERISTICHE
p (bar)

PERFORMANCE CURVES
7.5
PRESSIONE / PRESSURE -

6 V2
=

4.5
H1
H

3
V1
=

1.5

0 30 60 90 120 150

PORTATA / FLOW - Q (l/min) = =


F (n8)
H3

Corpo in acciaio / Steel body

A900800.04.00 136 6 41.5 64.5 14 89 57.2 75 27.8 12.5 20 1"SAE6000 OR 4131 32.92x3.53
COD. L L1 L2 L3 L4 H H1 H2 H3 F F1 U1-U2 O-RING

DESCRIZIONE DESCRIPTION

Valvola anticavitazione Anticavitation valve


con attacco 1" SAE 6000. with 1" SAE 6000 ports.

Codice Ordinazione Pressione di lavoro Pressione Max Dimensione Porte Peso

Ordering Code Working Pressure Max Pressure Port Size Weight


V1-V2 1"G
A900800.04.00 320 bar 350 bar 4.6 kg
D 3/4"G
Pag. 90.02.01

Valvola di scarico doppia


Dual unloading valve

L
L1 L2 L1 S2

H1
CURVE CARATTERISTICHE D (n.2)
PRESSIONE / PRESSURE - p (bar)

H5
PERFORMANCE CURVES
T2 T1
12

H
10
2
-T P1
8 T1
H3

6 1 P2
/P
A1 A1 A2
H4

4
2 L5
S1
H2

0
15 30 45 60 75 80 90

(N.2)
L3 L4 L4
PORTATA / FLOW - Q (l/min) S

A900607.01.00 110 36 38 20 35 7 60 30 64 100 86 4,7 54 24 8.5


COD. L L1 L2 L3 L4 L5 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Blocco idraulico con due Hydraulic block with two


elettrovalvole normalmente solenoid valves to upload
aperte per la messa a scarico two separated hydraulic lines.
di due linee idrauliche.

Codice Alimentazione Portata Pressione Dimensione Porte Peso


Ordinazione Elettrovalvola Massima Max
Elecrovalve Max
Ordering Code Power Supply Max Flow Port Size Weight
Pressure
T1, T2 1"G
A900607.01.00 28 V 80 l/min 350 bar 5 kg
A1, A2, A3, A4 3/4"G
Pag. 90.03.01

Valvola di esclusione pompa doppia


Unloading valve for twin pumps

L
L1 L2 S2
L3 V1 L3
V2 HEX4
HEX5 HEX13

H1
HEX17
D (n.4)

M BP

H
H4

H3
U AP

H2
S1
S

Corpo in alluminio / Aluminium body

B900412.01.00 100 37 38 6 50 25 19 120 52 19 36 95 M6


COD. L L1 L2 L3 S S1 S2 H H1 H2 H3 H4 D

DESCRIZIONE DESCRIPTION

Valvola di esclusione alta-bassa Two pumps hi-low


pressione per pompe doppie. unloading valve.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Codice Campo di Taratura Incremento Portata Massima Dimensione Porte Peso


Ordinazione Taratura Standard per Giro

Ordering Code Pressure Range Standard Pressure Max Flow Port Size Weight
Setting Increase
AP AP 3/8"G
V1 5-50 bar 50 bar 110 bar/turn 20 l/min
M M 1/4"G
B900412.01.00 1.73 kg
BP, U 45 l/min BP, U 1/2"G
V2 180-210 bar 210 bar 135 bar/turn
T 55 l/min T 3/4"G
Pag. 90.03.02

Valvola di esclusione pompa doppia


Unloading valve for twin pumps

~50.5 40 24
P2
C

24
Vmax
M

61

64
Cpil

P1 23 Cpil
Vuni VMS T
64

24,5
P2-AP M
P1-BP
10
T
M8x10 Vmax
105

105
85

58
58
23,5
Vuni
10

9 59,5 HEX13

20 max
88 64
7,5 88 HEX4

64
VMS 23

HEX17
HEX5 C
64
51
24

24

DESCRIZIONE DESCRIPTION

Valvola di esclusione alta-bassa Two pumps hi-low unloading


pressione per pompe doppie. valve.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Corpo in alluminio / Aluminium body

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
Vmax 100-350 bar 210 bar 110 bar/turn P1 50 bar P1, P2, T, C 3/4"G
A900612.01.00 120 l/min 2.66 kg
Cpil 50-210 bar 50 bar 36 bar/turn P2 210 bar M 1/4"G
Pag. 90.03.02A

Valvola di esclusione pompa doppia


Unloading valve for twin pumps

C ~50.5 44,5 29,5


P2
Vmax
M

25,5
Cpil

71

74
Vuni VMS T
P1 Cpil
P2-AP P1-BP 9 32
74,5

24,5
13,5
M

27,5
T
M8x10
Vmax

108,5
85

66
66
28,5
Vuni
10

23 100 HEX13
63

16,6
74
100 HEX4

74
VMS 32

HEX17

HEX5
25,5

74
61

29,5

DESCRIZIONE DESCRIPTION

Valvola di esclusione alta-bassa Two pumps hi-low unloading


pressione per pompe doppie. valve.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003 - 916005

Corpo in acciaio / Steel body

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Range Standard Pressure Max Flow Max Port Size Weight
Setting Increase Pressure
Vmax 100-350 bar 310 bar 110 bar/turn P1 150 bar P1, P2, T, C 1"G
A900812.01.00 200 l/min 7.69 Kg
Cpil 50-210 bar 150 bar 36 bar/turn P2 310 bar M 1/4"G
Pag. 90.05.00

Blocco idraulico integrato


Hydraulic integrated block

L5
G4 HEX17
M1 M G5

2 4 A

D (n2)

S3
S1
S
3

L4
1 valve 3
P L2 L L1
F4 F5 valve 1
L3 valve 4
F2
L4

H1
T

M
F1

G1
H4
H3
T
F

F3

H5

G
P

F2
F6

H2

G3
valve 2 valve 5 G2
L4 D (n2)

G5
G4
M1

VOLTAGGIO NOMINALE NOMINAL VOLTAGE A


S1

26 VDC
S2

valve 1
L7
Corpo in acciaio / Steel body L6
99 37.5 4.8 57.5 25 82 74 28 99 69 29 63 128 19 60.8 98 59 39 98 22 29 112 84 7.5 8 82.5 37.5 57.5 14 17 15 M8
L L1 L2 L3 L4 L5 L6 L7 S S1 S2 S3 H H1 H2 H3 H4 H5 F F1 F2 F3 F4 F5 F6 G G1 G2 G3 G4 G5 D

DESCRIZIONE DESCRIPTION

Valvola limitatrice di pressione Pressure limiting valve and


e limitatrice di usso. ow limiter. With few liters
Con pochi litri di portata regolata, of regulated ow, by operating
azionando lEV una piccola parte the EV a small part of the ow
della portata va a scarico. goes to drain. By actuating
Azionando la valvola 2 tutta la the valve 2 the entire
portata possa attraverso di essa. capacity can through it.

CODICE ORDINAZIONE SEALING ORDERING


PIOMBATURA CODE

916003

Codice Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso


Ordinazione Taratura Standard per Giro Massima Max

Ordering Code Pressure Standard Pressure Max Flow Max Port Size Weight
Range Setting Increase Pressure
A ,P ,T 3/4"G
A900600.03.00 100-350 bar 270 bar 150 bar/turn 90 l/min 350 bar 8.9 kg
M ,M1 1/4"G
Pag. 90.06.00

Valvola demergenza per freno rimorchio


Emergency trailer brake valve

DRIVE CONDITIONS:
(The split pin is not included)
The accumulator recharge while
the trailer brakes are actuated. Emergency brake released Emergency brake
(The shaft and the pin have engaged
to be turned anti clock B connected to A
wise against the lock)
B connected to C
B A

B
C

40
22
30
60
A
HAND PUMP

70
48
29

6
22
A

DESCRIZIONE DESCRIPTION
CAUTION !
Questa valvola frena il rimorchio This valve brakes the trailer when
When the trailer is coupled to the
quando accidentalmente si it is accidentally decoupled from
tractor, with the engine running,
disaccoppia dal trattore. A causa the tractor. Because of the
it's necessary to actuate the tractor
della perdita tra il corpo e il leakege between the body and
brake at least 5 seconds to enable the
blocco valvola dopo qualche ora the valve spool after some hours
complete recharge of the trailer
l'accumulatore pressurizza la the accumulator A pressurize the
emergency accumulator. This is an
linea C. La pompa manuale viene C line. The hand-Pump is used to
emergency brake valve not a park
utilizzata per scaricare questa discharge this pressure.
brake device.
pressione.

Corpo in acciaio / Steel body

Codice Ordinazione Pressione di Lavoro Dimensione Porte Peso

Ordering Code Working Pressure Port Size Weight

A903710.01.00 250 bar M18x1.5 1.36 kg


Pag. 90.07.00

Valvola di controllo rotazione e uscita stabilizzatori


Control valve for rotation and release stabilizers

V2

S1
Valve 2

S
C2 1 2 6 C3

L6 S8

S2
4 HEX4 L L2
C1 B S9 Valve 4
C4
HEX13

H1

Valve 3
3 A 5
V1

H4
H6
H5

H2

H3
H

D
S7 L1
Valve 1 S6 L3
L4 Valve 5
S4
S3

S5
L5 Valve 6

Corpo in alluminio / Aluminium body


89 40 6.4 69.5 15 43.5 64 42 16 45.5 27 59 3.5 16.5 45.5 16.5 20 113 ~30 105 95 44 82.8 61.5 8.5
L L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 S S1 S2 S3 S4 S5 H H1 H2 H3 H4 H5 H6 D

DESCRIZIONE DESCRIPTION

Valvola controllo uscita e Control valve for release and


rotazione degli stabilizzatori. rotation of the stabilizers.

Codice Rapporto di Campo di Taratura Incremento Portata Pressione Dimensione Porte Peso
Ordinazione Pilotaggio Taratura Standard per Giro Massima Max

Ordering Code Pilot Ratio Pressure Standard Pressure Max Max Port Size Weight
Range Setting Increase Flow Pressure
1 8:1 - 30 bar C.P. -
V1, V2, 3/8"G
2 - - 64 bar 17 bar/turn C1, C2
B900301.01.00 4 - 100-350 bar 150 bar 150 bar/turn 45 l/min 250 bar 1.8 kg
5 5:1 - - -
C3, C4 1/4"G
6 5:1 - - -
Cavit - Cavity

Cavit
Cavity
Pag. 99.01.00

Cavit SAE
SAE cavity

HBS.93.U.02A

15
28
+ 0,10
20,6 0
0.1 A
3/4"-16UNF-2B 3.2
A
+ 0,10

1.6
0.05 A 17,5 0

R0
,1
A

5
+ 0,30
0
45

2,6
13

14
20,5

2 DETAIL A
9
29

1.6
20

1.6

+ 0,05
12,7

0
1,5

0.05 A

1
12 max.

HBS.94.U.02A

30 15

0.05 A + 0,10
23,9 0
0.1 A
7/8"-14UNF-2B 3.2
A
+ 0,10
20,5
R0

0
1.6

,1
5

B
+ 0,30
0

45
2,6
15

18
25,5

2 DETAIL B
34

11

20
1.6
1,5

+ 0,05
1.6

15,87 0
0.05 A

1
15 max.
Pag. 90.01.01

Cavit SAE
SAE cavity

HBS.96.U.02A

35
0.05 A + 0,01
29,2 0
0.1 A
1-1/16"-12UN-2B
A
+ 0,10
24,9

- 0,200
0

0
15

26

17,5 max
20

3.2
36,5

+ 0,30
2

1.6
0
48

R0
3,3

,15
1.6

20 45
1.6

+ 0,05
22,22 0
0.05 A
DETAIL A

1
19 max.

HBS.97.U.02A

42
+ 0,10
0.05 A 35,5 0
0.1 A
1-5/16"-12UN-2B
A
+ 0,10
31,3 0
- 0,200

B 15
0
25

18,5 max
20

3.2
36

+ 0,30

2
R0
0

1.6
49

,1
5
3,3

45
1.6

1.6

20 + 0,05
28,6 0
0.05 A DETAIL B

1
24 max.
Pag. 99.02.00

Cavit SAE
SAE cavity

HBS.93.U.03A
15
28,5 0.030
20,6 0,050
R0.2 3/4-16UNF-2B 0.020
0,5

3.2

6 max.
15,2
13

1.6
+0,100
0 18
+0,100
0

29,5
3
32
43,5

1.6

1.6

30

2
6 max.
1.6

1.6

30

1 13
+0,020
14,25 0
+0,020
15,85 0

HBS.94.U.03A
0.030
1.6

15
30 0.020
+ 0,100
R0,15 max 23,9 0

7/8-14UNF-2B
1

3.2
+ 0,3
0,100

4
14

14
2,6

45
18
31,5
- 0,100

11,5

3
0
+ 0,200

20
40

1.6

1.6
0

+ 0,050
50

19,05 0

2
20

1.6

+ 0,050
1.6

17,47

1
15 max
Pag. 99.02.01

Cavit SAE
SAE cavity

HBS.96.U.03A
3.2 15
38,1
0.030
+0,100
29,1 0 0.020
R0.15
1-1/16-12UN
3.2

1
22,2 0,100
4,8 max

+0,200

22 min
- 0,200
45

3,3 0

41,3 0,100
0
3

26,5

59,2 0,100
- 0,200
0
1.6

49,5
20

23,82 0,025

2
20
1.6

12,7 max
1.6

1
20,62 max.
22,25 0,025

HBS.90.U.03A
3.2

15
0.030
38
+0,100
32,3 0 0.020
1 3/16 -12 UNF-2A
R0.2max 3.2
+0,400

16 max.
0
19

27
3,3

37

3
73 0,100
53

12 max.

79 min.

2
20

1.6

1.6

27 H8
12 max.

20
1.6

1.6

25 H8

1
24,5
Pag. 99.03.00

Cavit SAE
SAE cavity

HBS.94.U.04A
0.030
0
0.020

3.2
0

4
22

HBS.96.U.04A
3.2 0.030

0.020
3.3 0

3.2
0

22.2
0
Pag. 99.04.00

Cavit METRICHE
METRICAL cavity

HBS.38.M.02A

1.6
+0,070
0.030
21,85 +0,020
45
20,65
0.020
30
M20x1.5
1,7

3.2
5,7

29,5
11
+0,130
39,8 +0,050

32,2

30
2 14
1.6

1
14
+0,05
17,5 0

HBS.39.M.02A
0.030
30

0.020
1.6

23 0,050
+0,100
0

M22x1.5
0,8
3,5

3.2

2
15

15,5
18
33,5
7 max.

1.6
1.6

30

1
16
+0,020
19 0
Pag. 99.05.00

Cavit METRICHE
METRICAL cavity

HBS.37.M.03A
0.030
+ 0,200 15
27,5 0
0.020

1.6
0
19,6 -0,100

R0,2max M18x1,5

5,5
3.2

3 -0,100

18 0,100
13

12
3

0
28

33 0,100
42
1.6

+ 0,020
1.6

15 0
2
20
1.6
1.6

20

14 0
+ 0,020 1

HBS.38.M.03A
0.030

21,85 0,020 0.020


1.6

1.6
0.8

20,65 0,020
17.5 0.100

3
11.5

3.2
1.6
4 0.100
14
27.4 0.100

19.5
35 +0.050
+0.200

M20x1.5-H6
2
13

30 1.6
0
.5

R0.5

114
1.6

0
17.5 -0.05
Pag. 99.05.01

Cavit METRICHE
METRICAL cavity

HBS.39.M.03A
30 0.030

1.6
+0,150 0.020
23 0

M22x1.5
0,2
3,5
13
15
21

33
3
38
50

9,5 max.

1.6
30

2
1.6
1.6

9,5 max.

30

1
1.6

+0,020
18 0

+0,020
19 0

HBS.42.M.03A
0.030
1.6

15
40
+ 0,100
0.020
29,2 0
+ 0,050

M27x1,5-6H
3,2 0

3.2
20,5 0,100
16,2 min.
18

3 45
10 max.

42 0,100
36
4 max.

1.6

30
56


2
1.6

1.6

30
1.6

1 + 0,050
23 0
+ 0,050
24,5 0
Pag. 99.05.02

Cavit METRICHE
METRICAL cavity

HBS.46.M.03A

1.6
15 0.030
39
+0,100
35,4 0 0.020

3,1 0,100
M33x2
3.2
21 max.

R1.5
30 0,050

18
46 max.
55 0,050

3
68 min.

1.6

2
+0,075
28 0

1.6
30
1.6

1
+0,075
30
1.6

27 0

HBS.46.M.03B
1.6

15 0.030
46
+0,100
35,4 0 0.020
+0,200

M33x2
0

R0.2
3,1

3.2
19
+0,300

30
0

3
39
58

- 0,100
- 0,200
16,5 max.

87,35
79

67
16,5 max.

30

96,5

1.6

2
1.6

29 H8

27 H8

1
1.6
1.6

30
18,5 max.

26,5
Pag. 99.05.03

Cavit METRICHE
METRICAL cavity

HBS.48.M.03A 0.030

6
45

1.
30

1.6 + 0,050 0.020
39,67 0

1
+ 0,050

1.6
0,7

36,52 0

14.3 max
M36x2-6H
45
+ 0,1

3
0
22,2

3.2

8
+ 0,5
25,4

0
4,8

0,1

+ 0,120
19
2

0
36,5

46,22
22.2 max

1
1
0,5x45

24,5
1.6 30
+ 0,050
31,75 0
1.6

HBS.52.M.03A
0.030
1.6

15
66 0.020
+ 0,100
44,4 0

M42x2
3.2
3,1
19,5
33

44
1.6

66


3 30
20 max

77
20 max

117 min
1.6

1.6

89

30
38 H8 2
1.6

36H8

35,5
Pag. 99.06.00

Cavit METRICHE
METRICAL cavity

HBS.38.M.04A
0.030

0.020
0
2,3,4 : MAX 14.3

1
Pag. 99.07.00

Cavit BSPP
BSPP cavity

HBS.02.G.03A

1/4"G
0.030

0,5
3.2 3 0.020
17

18,5

26,5
30

1.6

Rmax 1.5

1
8

11,8 0,050

HBS.04.G.03A
0.030
1.6

30 1
28min
0.020
+ 0,200
22 0
14,5 0,200
+ 0,400

1/2"G
12,5min

2,5 0

18H8 R0,2max
3.2
+ 0,200

3
17,5 0

45
+1
27,5 0
+ 0,200
33 0

1.6
+1
43 0

30
57

1.6

5max

2
29 0,200
1.6

30
8 max
1.6

16 H8

1
16 max
Pag. 99.07.01

Cavit BSPP
BSPP cavity

HBS.06.G.02A
0.030
1

0.020

1. 6
31

+0,100
+0,100
27,1 0

3,5 0
3/4"G

0,8
3.2
19,5

19
25,5
45
2

37
1.6
13 max.

1.6
30

1
20
+0,020
23,5 0

HBS.08.G.02A
0.030

0.020
1.6

8
42
+ 0,1
34,5 0
R0.2
1"G
5

3.2
20
28

2
40

52
20

1.6

1.6

30

1
25
28 H7
Pag. 99.08.00

Cavit SPECIALI
SPECIAL cavity

HBS.99.S.02A

1.6
4 0.030
30

27,3
+0,050
0
0.020
1-14 UNS

3,9
15

24 min.

47 max.
49
57,5

2
30
1,5

1.6

1.6

1
16,5

19,05 H7

+ 0,050
HBS.99.S.02B 27,38 0
0.030
1.6

+ 0,050
26,19
30

0
0.020
1-14UNS-2B
1,6

16
4

45
24,6
39
+ 0,120

18

1.6
47,82 0

2
30

0,3x45max
1
0
17,5 - 0,050

+ 0,050
22,23 0

+ 0,100
23,7 0
Pag. 99.08.01

Cavit SPECIALI
SPECIAL cavity

HBS.95.S.03A

30 0.030

1.6
45 27,4 0.020

1.6
1.
6
26,2

1,5
17,5 min.

3
3.2
1.6
4
17
28 max.

45
2
35,2

30
1.6

1.6

1
22,3
1-14UNF

HBS.96.S.03A
0.030
1.6

15
0.020
36
+0,300

+0,100
29,2 0
0

1 1/16-12 UNF-2A
3,3

R0.2
14,5

3.2
19
15 max.

3
41

12 max.

67
73 min.

2 20
1.6

20

1
1.6

12 max.

22,22 H7
23,81 H7
Pag. 99.08.02

Cavit SPECIALI
SPECIAL cavity

HBS.38.S.02A
0.030

1.6
0.020
+0,021
21 0

0.6X30
M20X1.5
5

17
33 0,100

23
16

29
2
3.2
20 min.

1
13
YOUR HBS CONTACT

Surname:

Name:

E-mail:

Phone:

Mobile phone:

Notes:
H.B.S. srl

Via Mastroppa 4/6


46040 Monzambano
Mantova - Italy
Phone: ++390376800200
E-mail: customerservice@hbs.it

H.B.S. Co. Beijing LTD

N. 6102 Bldg, 16 Guanghua Rd


Tongzhou Industrial Devel. Zone
Beijing China
Phone: ++86 10 61507457
E-mail: zhuhua@hbsvalves.com.cn

H.B.S. do Brasil Ltda

Rua Domenico Martin Mezzomo, 159


Bairro: Santa Catarina 95030-230
Caxias do Sul - RS / Brasil
Phone: ++55 54 30282900
E-mail: lulian@hbs.it

H.B.S. India Pvt Ltd

3,Gokul Industrial Estate


Plot n. 150 - Marol Co-Op.Ind.Estate
Mumbai - 400059 - India
Phone: ++91 22 28560202
E-mail: sgupta@hbsvalves.in