Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 13

+++ 231232_Airmadidi_Atas_MBTS 2017-09-02 14:45:35

O&M #325
%%LST ALMLOG: ALMTP=ALL;%%
RETCODE = 0 Operation succeeded

ALARM 5988 Fault Minor SRAN 26266 Communication


Sync serial No. = 12381
Alarm name = Time Synchronization Failure
Alarm raised time = 2017-09-02 14:28:29
Location info = Time Source Type=NTP, Specific Problem=Other
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5987 Fault Major SRAN 25901 Trunk


Sync serial No. = 12380
Alarm name = Remote Maintenance Link Failure
Alarm raised time = 2017-09-02 14:23:58
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5983 Fault Major SRAN 26235 Hardware


Sync serial No. = 12379
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 14:05:28
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 14:06:48
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5982 Fault Major SRAN 28006 Signaling


Sync serial No. = 12378
Alarm name = Radio Signaling Link Disconnected
Alarm raised time = 2017-09-02 14:03:49
Location info = Local Cell ID=2, Carrier No.=8
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 14:07:52
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5984 Fault Major SRAN 29240 Signaling


Sync serial No. = 12377
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 14:05:33
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 14:07:52
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5985 Fault Major SRAN 28016 QoS
Sync serial No. = 12376
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 14:05:34
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 14:07:44
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5986 Event Minor SRAN 26535 Hardware


Sync serial No. = 12375
Alarm name = RF Unit Startup
Alarm raised time = 2017-09-02 14:07:30
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU,
Reset Cause=Board Power-off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5981 Fault Minor SRAN 25900 Trunk


Sync serial No. = 12370
Alarm name = IP PM Activation Failure
Alarm raised time = 2017-09-02 13:59:24
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100,
Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific
Problem=Uplink
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5980 Fault Critical SRAN 25672 Environment


Sync serial No. = 12369
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:59:38
Location info = Cabinet No.=0, Subrack No.=8, Slot No.=0, Board Type=TCU,
Specific Problem=Door Status Alarm
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5979 Fault Critical SRAN 25672 Environment


Sync serial No. = 12368
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:59:24
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=Door Status Alarm
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5978 Fault Critical SRAN 25672 Environment


Sync serial No. = 12367
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:59:24
Location info = Cabinet No.=1, Subrack No.=11, Slot No.=0, Board Type=FMU,
Specific Problem=Door Status Alarm
Cleared type = Not cleared
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5977 Event Minor SRAN 26213 Running


Sync serial No. = 12366
Alarm name = NE Startup
Alarm raised time = 2017-09-02 13:58:54
Location info = Reset Cause=Board Power-Off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5976 Fault Critical SRAN 25672 Environment


Sync serial No. = 12365
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:55:08
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=Door Status Alarm
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5975 Fault Major SRAN 28016 QoS


Sync serial No. = 12364
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 13:53:24
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5974 Fault Major SRAN 29240 Signaling


Sync serial No. = 12363
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 13:53:19
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5973 Fault Major SRAN 26235 Hardware


Sync serial No. = 12362
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 13:53:13
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5967 Fault Critical SRAN 25672 Environment


Sync serial No. = 12361
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:27:10
Location info = Cabinet No.=1, Subrack No.=11, Slot No.=0, Board Type=FMU,
Specific Problem=Door Status Alarm
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5966 Fault Critical SRAN 25672 Environment


Sync serial No. = 12360
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:27:06
Location info = Cabinet No.=0, Subrack No.=8, Slot No.=0, Board Type=TCU,
Specific Problem=Door Status Alarm
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5956 Fault Minor SRAN 26266 Communication


Sync serial No. = 12359
Alarm name = Time Synchronization Failure
Alarm raised time = 2017-09-02 13:01:07
Location info = Time Source Type=NTP, Specific Problem=Other
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5947 Fault Minor SRAN 25900 Trunk


Sync serial No. = 12358
Alarm name = IP PM Activation Failure
Alarm raised time = 2017-09-02 12:41:31
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100,
Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific
Problem=Uplink
Cleared type = Reset cleared
Cleared time = 2017-09-02 13:58:54
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5971 Fault Critical SRAN 25622 Power


Sync serial No. = 12354
Alarm name = Mains Input Out of Range
Alarm raised time = 2017-09-02 13:49:55
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=AC Failure
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:51:27
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5972 Event Warning SRAN 26290 Power


Sync serial No. = 12352
Alarm name = Backup Power Saving
Alarm raised time = 2017-09-02 13:51:29
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT,
Power Saving Status=Quit the Power Saving Status
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5969 Fault Major SRAN 65033 Environment


Sync serial No. = 12351
Alarm name = PHASE FAILURE
Alarm raised time = 2017-09-02 13:49:46
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=19, Port No.=0,
Board Type=UPEU
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:51:15
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5970 Event Warning SRAN 26290 Power


Sync serial No. = 12349
Alarm name = Backup Power Saving
Alarm raised time = 2017-09-02 13:50:26
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT,
Power Saving Status=Enter the Common Power Saving Status
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5948 Fault Major SRAN 25622 Power


Sync serial No. = 12347
Alarm name = Mains Input Out of Range
Alarm raised time = 2017-09-02 12:41:31
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=AC Undervoltage
Cleared type = Manually cleared
Cleared time = 2017-09-02 13:48:52
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5968 Fault Critical SRAN 25672 Environment


Sync serial No. = 12346
Alarm name = Burglar Alarm
Alarm raised time = 2017-09-02 13:32:52
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=Door Status Alarm
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:33:12
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5962 Fault Major SRAN 26235 Hardware


Sync serial No. = 12342
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 13:11:11
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:23:00
Root alarm CSN = 5964
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5964 Fault Major SRAN 26234 Hardware


Sync serial No. = 12341
Alarm name = BBU CPRI Interface Error
Alarm raised time = 2017-09-02 13:11:04
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2,
Board Type=UBBP, Specific Problem=CPRI Interface Reception Error
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:22:46
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5963 Fault Major SRAN 29240 Signaling


Sync serial No. = 12340
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 13:11:13
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:23:17
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5961 Fault Major SRAN 28016 QoS


Sync serial No. = 12339
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 13:10:34
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:23:14
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5965 Event Minor SRAN 26535 Hardware


Sync serial No. = 12336
Alarm name = RF Unit Startup
Alarm raised time = 2017-09-02 13:23:05
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU,
Reset Cause=Board Power-off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5958 Fault Major SRAN 26235 Hardware


Sync serial No. = 12328
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 13:01:42
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:03:31
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5957 Fault Major SRAN 29240 Signaling


Sync serial No. = 12327
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 13:01:40
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:04:08
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5959 Fault Major SRAN 28016 QoS


Sync serial No. = 12326
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 13:01:44
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 13:04:04
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5960 Event Minor SRAN 26535 Hardware


Sync serial No. = 12323
Alarm name = RF Unit Startup
Alarm raised time = 2017-09-02 13:03:41
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU,
Reset Cause=Board Power-off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5952 Fault Major SRAN 26235 Hardware


Sync serial No. = 12317
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 12:55:24
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:55:59
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5955 Fault Major SRAN 26234 Hardware


Sync serial No. = 12316
Alarm name = BBU CPRI Interface Error
Alarm raised time = 2017-09-02 12:55:25
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2,
Board Type=UBBP, Specific Problem=CPRI Interface Reception Error
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:55:59
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5954 Fault Major SRAN 28016 QoS


Sync serial No. = 12314
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 12:55:34
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:56:44
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5953 Fault Major SRAN 29240 Signaling


Sync serial No. = 12313
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 12:55:31
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:56:44
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5949 Fault Major SRAN 26235 Hardware


Sync serial No. = 12307
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 12:44:00
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:48:52
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G
(Number of results = 40)

To be continued...

--- END

+++ 231232_Airmadidi_Atas_MBTS 2017-09-02 14:45:35


O&M #325
%%LST ALMLOG: ALMTP=ALL;%%
RETCODE = 0 Operation succeeded

ALARM 5950 Fault Major SRAN 29240 Signaling


Sync serial No. = 12306
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 12:43:58
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:49:09
Root alarm CSN = 5949
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5951 Fault Major SRAN 28016 QoS


Sync serial No. = 12305
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 12:44:12
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 12:49:04
Root alarm CSN = 5949
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5946 Event Minor SRAN 26213 Running


Sync serial No. = 12299
Alarm name = NE Startup
Alarm raised time = 2017-09-02 12:41:01
Location info = Reset Cause=Board Power-Off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5944 Fault Major SRAN 25621 Power


Sync serial No. = 12298
Alarm name = Power Supply DC Output Out of Range
Alarm raised time = 2017-09-02 11:39:53
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Sub Slot No.=NULL, Specific Problem=DC Undervoltage
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5943 Fault Major SRAN 25622 Power


Sync serial No. = 12297
Alarm name = Mains Input Out of Range
Alarm raised time = 2017-09-02 11:33:04
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=AC Failure
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5941 Fault Major SRAN 65033 Environment


Sync serial No. = 12296
Alarm name = PHASE FAILURE
Alarm raised time = 2017-09-02 11:32:55
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=19, Port No.=0,
Board Type=UPEU
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5939 Fault Major SRAN 28016 QoS


Sync serial No. = 12295
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 11:10:11
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5934 Fault Major SRAN 29240 Signaling


Sync serial No. = 12294
Alarm name = Cell Unavailable
Alarm raised time = 2017-09-02 10:57:17
Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell
Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3,
Specific Problem=RF module abnormal
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Root alarm CSN = 5931
= 5932
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5932 Fault Major SRAN 26538 Hardware


Sync serial No. = 12293
Alarm name = RF Unit Clock Problem
Alarm raised time = 2017-09-02 10:57:29
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5930 Fault Major SRAN 25888 Trunk


Sync serial No. = 12292
Alarm name = SCTP Link Fault
Alarm raised time = 2017-09-02 10:32:55
Location info = Link No.=70003, Description=eNodeB:MCC_510 MNC_89
eNodeBId_523218, Peer IP Address=10.59.43.111, Service Type=X2-AP
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5895 Fault Major SRAN 25888 Trunk


Sync serial No. = 12291
Alarm name = SCTP Link Fault
Alarm raised time = 2017-09-02 09:21:49
Location info = Link No.=70002, Description=eNB:MCC_510 MNC_89
GlobaleNBId_510-89-523116, Peer IP Address=10.59.43.101, Service Type=X2-AP
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5892 Fault Minor SRAN 25900 Trunk


Sync serial No. = 12290
Alarm name = IP PM Activation Failure
Alarm raised time = 2017-09-02 09:21:49
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100,
Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific
Problem=Uplink
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5891 Fault Warning SRAN 29204 Signaling


Sync serial No. = 12289
Alarm name = X2 Interface Fault
Alarm raised time = 2017-09-02 09:21:49
Location info = X2Interface ID=4294967295, CN Operator ID=65535,
Description=NULL, Specific Problem=Lower-layer link fault
Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0
Cleared type = Reset cleared
Cleared time = 2017-09-02 12:41:01
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5945 Event Minor SRAN 25890 Trunk


Sync serial No. = 12288
Alarm name = SCTP Link Path Switchover
Alarm raised time = 2017-09-02 12:40:17
Location info = Link No.=70000, Switchover Direction=Main-to-Standby
Switchover, Description=MME:MCC_510 MNC_89 MMEI_33329_1, Service Type=S1-AP
Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL
Special info1 = AF_L=231232_Airmadidi_Atas_4G

ALARM 5893 Fault Major SRAN 25622 Power


Sync serial No. = 12286
Alarm name = Mains Input Out of Range
Alarm raised time = 2017-09-02 09:21:49
Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU,
Specific Problem=AC Undervoltage
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:33:03
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5942 Event Warning SRAN 26290 Power


Sync serial No. = 12284
Alarm name = Backup Power Saving
Alarm raised time = 2017-09-02 11:33:35
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT,
Power Saving Status=Enter the Common Power Saving Status
Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G

ALARM 5940 Fault Major SRAN 26533 Running


Sync serial No. = 12282
Alarm name = RF Unit Software Program Error
Alarm raised time = 2017-09-02 11:25:32
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:26:06
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5933 Fault Major SRAN 26235 Hardware


Sync serial No. = 12280
Alarm name = RF Unit Maintenance Link Failure
Alarm raised time = 2017-09-02 10:58:08
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:08:59
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5936 Fault Major SRAN 26234 Hardware


Sync serial No. = 12276
Alarm name = BBU CPRI Interface Error
Alarm raised time = 2017-09-02 10:58:05
Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2,
Board Type=UBBP, Specific Problem=CPRI Interface Reception Error
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:08:42
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5931 Fault Major SRAN 26529 Hardware


Sync serial No. = 12275
Alarm name = RF Unit VSWR Threshold Crossed
Alarm raised time = 2017-09-02 10:54:36
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, TX Channel
No.=0, Board Type=MRFU, VSWR Alarm Threshold (0.1)=18, VSWR(0.1)=23, Output Power
(0.1 dBm)=470
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:09:53
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5935 Fault Major SRAN 28016 QoS


Sync serial No. = 12273
Alarm name = GSM Local Cell Unusable
Alarm raised time = 2017-09-02 10:57:21
Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable
Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0
Cleared type = Normally cleared
Cleared time = 2017-09-02 11:09:11
Root alarm CSN = 5931
= 5932
Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G

ALARM 5938 Event Minor SRAN 26535 Hardware


Sync serial No. = 12272
Alarm name = RF Unit Startup
Alarm raised time = 2017-09-02 11:09:04
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU,
Reset Cause=Board Power-off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5937 Event Minor SRAN 26535 Hardware


Sync serial No. = 12268
Alarm name = RF Unit Startup
Alarm raised time = 2017-09-02 11:07:38
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU,
Reset Cause=Board Power-off
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G

ALARM 5926 Fault Major SRAN 26538 Hardware


Sync serial No. = 12258
Alarm name = RF Unit Clock Problem
Alarm raised time = 2017-09-02 10:12:02
Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU
Cleared type = Normally cleared
Cleared time = 2017-09-02 10:32:16
Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL
Special info1 = AF_G=231232_Airmadidi Atas_2G,
AF_L=231232_Airmadidi_Atas_4G
(Number of results = 24)

2 reports in total

--- END