This document contains logs of various alarms from a network element between September 2, 2017 14:23 and 14:45. There were alarms related to time synchronization failure, remote maintenance link failure, RF unit maintenance link failure, radio signaling link disconnected, cell unavailable, GSM local cell unusable, and burglar alarms from opened cabinet doors. Many alarms were initially un-cleared but were later cleared between 14:06 and 14:08, likely after issue resolution.
This document contains logs of various alarms from a network element between September 2, 2017 14:23 and 14:45. There were alarms related to time synchronization failure, remote maintenance link failure, RF unit maintenance link failure, radio signaling link disconnected, cell unavailable, GSM local cell unusable, and burglar alarms from opened cabinet doors. Many alarms were initially un-cleared but were later cleared between 14:06 and 14:08, likely after issue resolution.
This document contains logs of various alarms from a network element between September 2, 2017 14:23 and 14:45. There were alarms related to time synchronization failure, remote maintenance link failure, RF unit maintenance link failure, radio signaling link disconnected, cell unavailable, GSM local cell unusable, and burglar alarms from opened cabinet doors. Many alarms were initially un-cleared but were later cleared between 14:06 and 14:08, likely after issue resolution.
Sync serial No. = 12381 Alarm name = Time Synchronization Failure Alarm raised time = 2017-09-02 14:28:29 Location info = Time Source Type=NTP, Specific Problem=Other Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5987 Fault Major SRAN 25901 Trunk
Sync serial No. = 12380 Alarm name = Remote Maintenance Link Failure Alarm raised time = 2017-09-02 14:23:58 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7 Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5983 Fault Major SRAN 26235 Hardware
Sync serial No. = 12379 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 14:05:28 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 14:06:48 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5982 Fault Major SRAN 28006 Signaling
Sync serial No. = 12378 Alarm name = Radio Signaling Link Disconnected Alarm raised time = 2017-09-02 14:03:49 Location info = Local Cell ID=2, Carrier No.=8 Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 14:07:52 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5984 Fault Major SRAN 29240 Signaling
Sync serial No. = 12377 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 14:05:33 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 14:07:52 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G ALARM 5985 Fault Major SRAN 28016 QoS Sync serial No. = 12376 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 14:05:34 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 14:07:44 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5986 Event Minor SRAN 26535 Hardware
Sync serial No. = 12375 Alarm name = RF Unit Startup Alarm raised time = 2017-09-02 14:07:30 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU, Reset Cause=Board Power-off Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5981 Fault Minor SRAN 25900 Trunk
Sync serial No. = 12370 Alarm name = IP PM Activation Failure Alarm raised time = 2017-09-02 13:59:24 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100, Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific Problem=Uplink Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5980 Fault Critical SRAN 25672 Environment
Sync serial No. = 12369 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:59:38 Location info = Cabinet No.=0, Subrack No.=8, Slot No.=0, Board Type=TCU, Specific Problem=Door Status Alarm Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5979 Fault Critical SRAN 25672 Environment
Sync serial No. = 12368 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:59:24 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=Door Status Alarm Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5978 Fault Critical SRAN 25672 Environment
Sync serial No. = 12367 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:59:24 Location info = Cabinet No.=1, Subrack No.=11, Slot No.=0, Board Type=FMU, Specific Problem=Door Status Alarm Cleared type = Not cleared Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5977 Event Minor SRAN 26213 Running
Sync serial No. = 12366 Alarm name = NE Startup Alarm raised time = 2017-09-02 13:58:54 Location info = Reset Cause=Board Power-Off Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5976 Fault Critical SRAN 25672 Environment
Sync serial No. = 12365 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:55:08 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=Door Status Alarm Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5975 Fault Major SRAN 28016 QoS
Sync serial No. = 12364 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 13:53:24 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5974 Fault Major SRAN 29240 Signaling
Sync serial No. = 12363 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 13:53:19 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5973 Fault Major SRAN 26235 Hardware
Sync serial No. = 12362 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 13:53:13 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5967 Fault Critical SRAN 25672 Environment
Sync serial No. = 12361 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:27:10 Location info = Cabinet No.=1, Subrack No.=11, Slot No.=0, Board Type=FMU, Specific Problem=Door Status Alarm Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5966 Fault Critical SRAN 25672 Environment
Sync serial No. = 12360 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:27:06 Location info = Cabinet No.=0, Subrack No.=8, Slot No.=0, Board Type=TCU, Specific Problem=Door Status Alarm Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5956 Fault Minor SRAN 26266 Communication
Sync serial No. = 12359 Alarm name = Time Synchronization Failure Alarm raised time = 2017-09-02 13:01:07 Location info = Time Source Type=NTP, Specific Problem=Other Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5947 Fault Minor SRAN 25900 Trunk
Sync serial No. = 12358 Alarm name = IP PM Activation Failure Alarm raised time = 2017-09-02 12:41:31 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100, Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific Problem=Uplink Cleared type = Reset cleared Cleared time = 2017-09-02 13:58:54 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5971 Fault Critical SRAN 25622 Power
Sync serial No. = 12354 Alarm name = Mains Input Out of Range Alarm raised time = 2017-09-02 13:49:55 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=AC Failure Cleared type = Normally cleared Cleared time = 2017-09-02 13:51:27 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5972 Event Warning SRAN 26290 Power
Sync serial No. = 12352 Alarm name = Backup Power Saving Alarm raised time = 2017-09-02 13:51:29 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT, Power Saving Status=Quit the Power Saving Status Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5969 Fault Major SRAN 65033 Environment
Sync serial No. = 12351 Alarm name = PHASE FAILURE Alarm raised time = 2017-09-02 13:49:46 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=19, Port No.=0, Board Type=UPEU Cleared type = Normally cleared Cleared time = 2017-09-02 13:51:15 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5970 Event Warning SRAN 26290 Power
Sync serial No. = 12349 Alarm name = Backup Power Saving Alarm raised time = 2017-09-02 13:50:26 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT, Power Saving Status=Enter the Common Power Saving Status Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5948 Fault Major SRAN 25622 Power
Sync serial No. = 12347 Alarm name = Mains Input Out of Range Alarm raised time = 2017-09-02 12:41:31 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=AC Undervoltage Cleared type = Manually cleared Cleared time = 2017-09-02 13:48:52 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5968 Fault Critical SRAN 25672 Environment
Sync serial No. = 12346 Alarm name = Burglar Alarm Alarm raised time = 2017-09-02 13:32:52 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=Door Status Alarm Cleared type = Normally cleared Cleared time = 2017-09-02 13:33:12 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5962 Fault Major SRAN 26235 Hardware
Sync serial No. = 12342 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 13:11:11 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 13:23:00 Root alarm CSN = 5964 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5964 Fault Major SRAN 26234 Hardware
Sync serial No. = 12341 Alarm name = BBU CPRI Interface Error Alarm raised time = 2017-09-02 13:11:04 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2, Board Type=UBBP, Specific Problem=CPRI Interface Reception Error Cleared type = Normally cleared Cleared time = 2017-09-02 13:22:46 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5963 Fault Major SRAN 29240 Signaling
Sync serial No. = 12340 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 13:11:13 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 13:23:17 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5961 Fault Major SRAN 28016 QoS
Sync serial No. = 12339 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 13:10:34 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 13:23:14 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5965 Event Minor SRAN 26535 Hardware
Sync serial No. = 12336 Alarm name = RF Unit Startup Alarm raised time = 2017-09-02 13:23:05 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU, Reset Cause=Board Power-off Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5958 Fault Major SRAN 26235 Hardware
Sync serial No. = 12328 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 13:01:42 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 13:03:31 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5957 Fault Major SRAN 29240 Signaling
Sync serial No. = 12327 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 13:01:40 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 13:04:08 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5959 Fault Major SRAN 28016 QoS
Sync serial No. = 12326 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 13:01:44 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 13:04:04 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5960 Event Minor SRAN 26535 Hardware
Sync serial No. = 12323 Alarm name = RF Unit Startup Alarm raised time = 2017-09-02 13:03:41 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU, Reset Cause=Board Power-off Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5952 Fault Major SRAN 26235 Hardware
Sync serial No. = 12317 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 12:55:24 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 12:55:59 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5955 Fault Major SRAN 26234 Hardware
Sync serial No. = 12316 Alarm name = BBU CPRI Interface Error Alarm raised time = 2017-09-02 12:55:25 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2, Board Type=UBBP, Specific Problem=CPRI Interface Reception Error Cleared type = Normally cleared Cleared time = 2017-09-02 12:55:59 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5954 Fault Major SRAN 28016 QoS
Sync serial No. = 12314 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 12:55:34 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 12:56:44 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5953 Fault Major SRAN 29240 Signaling
Sync serial No. = 12313 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 12:55:31 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 12:56:44 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5949 Fault Major SRAN 26235 Hardware
Sync serial No. = 12307 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 12:44:00 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 12:48:52 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G (Number of results = 40)
Sync serial No. = 12306 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 12:43:58 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 12:49:09 Root alarm CSN = 5949 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5951 Fault Major SRAN 28016 QoS
Sync serial No. = 12305 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 12:44:12 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 12:49:04 Root alarm CSN = 5949 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5946 Event Minor SRAN 26213 Running
Sync serial No. = 12299 Alarm name = NE Startup Alarm raised time = 2017-09-02 12:41:01 Location info = Reset Cause=Board Power-Off Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5944 Fault Major SRAN 25621 Power
Sync serial No. = 12298 Alarm name = Power Supply DC Output Out of Range Alarm raised time = 2017-09-02 11:39:53 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Sub Slot No.=NULL, Specific Problem=DC Undervoltage Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5943 Fault Major SRAN 25622 Power
Sync serial No. = 12297 Alarm name = Mains Input Out of Range Alarm raised time = 2017-09-02 11:33:04 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=AC Failure Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5941 Fault Major SRAN 65033 Environment
Sync serial No. = 12296 Alarm name = PHASE FAILURE Alarm raised time = 2017-09-02 11:32:55 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=19, Port No.=0, Board Type=UPEU Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5939 Fault Major SRAN 28016 QoS
Sync serial No. = 12295 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 11:10:11 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5934 Fault Major SRAN 29240 Signaling
Sync serial No. = 12294 Alarm name = Cell Unavailable Alarm raised time = 2017-09-02 10:57:17 Location info = Local Cell ID=3, Cell FDD TDD indication=FDD, NB-IoT Cell Flag=FALSE, Cell Name=231232_Airmadidi_Atas_4G-3, eNodeB ID=523197, Cell ID=3, Specific Problem=RF module abnormal Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Root alarm CSN = 5931 = 5932 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5932 Fault Major SRAN 26538 Hardware
Sync serial No. = 12293 Alarm name = RF Unit Clock Problem Alarm raised time = 2017-09-02 10:57:29 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5930 Fault Major SRAN 25888 Trunk
Sync serial No. = 12292 Alarm name = SCTP Link Fault Alarm raised time = 2017-09-02 10:32:55 Location info = Link No.=70003, Description=eNodeB:MCC_510 MNC_89 eNodeBId_523218, Peer IP Address=10.59.43.111, Service Type=X2-AP Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5895 Fault Major SRAN 25888 Trunk
Sync serial No. = 12291 Alarm name = SCTP Link Fault Alarm raised time = 2017-09-02 09:21:49 Location info = Link No.=70002, Description=eNB:MCC_510 MNC_89 GlobaleNBId_510-89-523116, Peer IP Address=10.59.43.101, Service Type=X2-AP Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5892 Fault Minor SRAN 25900 Trunk
Sync serial No. = 12290 Alarm name = IP PM Activation Failure Alarm raised time = 2017-09-02 09:21:49 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Session ID=100, Alarm Cause=Activation timeout, Peer IP Address=10.47.47.209, Specific Problem=Uplink Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5891 Fault Warning SRAN 29204 Signaling
Sync serial No. = 12289 Alarm name = X2 Interface Fault Alarm raised time = 2017-09-02 09:21:49 Location info = X2Interface ID=4294967295, CN Operator ID=65535, Description=NULL, Specific Problem=Lower-layer link fault Function = eNodeB Function Name=231232_Airmadidi_Atas_4G, objId=0 Cleared type = Reset cleared Cleared time = 2017-09-02 12:41:01 Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5945 Event Minor SRAN 25890 Trunk
Sync serial No. = 12288 Alarm name = SCTP Link Path Switchover Alarm raised time = 2017-09-02 12:40:17 Location info = Link No.=70000, Switchover Direction=Main-to-Standby Switchover, Description=MME:MCC_510 MNC_89 MMEI_33329_1, Service Type=S1-AP Special info = RAT_INFO=GUL, AFFECTED_RAT=L, DID=NULL Special info1 = AF_L=231232_Airmadidi_Atas_4G
ALARM 5893 Fault Major SRAN 25622 Power
Sync serial No. = 12286 Alarm name = Mains Input Out of Range Alarm raised time = 2017-09-02 09:21:49 Location info = Cabinet No.=5, Subrack No.=7, Slot No.=0, Board Type=PMU, Specific Problem=AC Undervoltage Cleared type = Normally cleared Cleared time = 2017-09-02 11:33:03 Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5942 Event Warning SRAN 26290 Power
Sync serial No. = 12284 Alarm name = Backup Power Saving Alarm raised time = 2017-09-02 11:33:35 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=7, Board Type=UMPT, Power Saving Status=Enter the Common Power Saving Status Special info = RAT_INFO=GUL, AFFECTED_RAT=GUL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_U=231232_AirmadidiAtas_3G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5940 Fault Major SRAN 26533 Running
Sync serial No. = 12282 Alarm name = RF Unit Software Program Error Alarm raised time = 2017-09-02 11:25:32 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 11:26:06 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5933 Fault Major SRAN 26235 Hardware
Sync serial No. = 12280 Alarm name = RF Unit Maintenance Link Failure Alarm raised time = 2017-09-02 10:58:08 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 11:08:59 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5936 Fault Major SRAN 26234 Hardware
Sync serial No. = 12276 Alarm name = BBU CPRI Interface Error Alarm raised time = 2017-09-02 10:58:05 Location info = Cabinet No.=0, Subrack No.=0, Slot No.=2, Port No.=2, Board Type=UBBP, Specific Problem=CPRI Interface Reception Error Cleared type = Normally cleared Cleared time = 2017-09-02 11:08:42 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5931 Fault Major SRAN 26529 Hardware
Sync serial No. = 12275 Alarm name = RF Unit VSWR Threshold Crossed Alarm raised time = 2017-09-02 10:54:36 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, TX Channel No.=0, Board Type=MRFU, VSWR Alarm Threshold (0.1)=18, VSWR(0.1)=23, Output Power (0.1 dBm)=470 Cleared type = Normally cleared Cleared time = 2017-09-02 11:09:53 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5935 Fault Major SRAN 28016 QoS
Sync serial No. = 12273 Alarm name = GSM Local Cell Unusable Alarm raised time = 2017-09-02 10:57:21 Location info = Local Cell ID=2, Specific Problem=RF Resource Unavailable Function = GBTS Function Name=231232_Airmadidi Atas_2G, objId=0 Cleared type = Normally cleared Cleared time = 2017-09-02 11:09:11 Root alarm CSN = 5931 = 5932 Special info = RAT_INFO=GUL, AFFECTED_RAT=G, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G
ALARM 5938 Event Minor SRAN 26535 Hardware
Sync serial No. = 12272 Alarm name = RF Unit Startup Alarm raised time = 2017-09-02 11:09:04 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU, Reset Cause=Board Power-off Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5937 Event Minor SRAN 26535 Hardware
Sync serial No. = 12268 Alarm name = RF Unit Startup Alarm raised time = 2017-09-02 11:07:38 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU, Reset Cause=Board Power-off Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G
ALARM 5926 Fault Major SRAN 26538 Hardware
Sync serial No. = 12258 Alarm name = RF Unit Clock Problem Alarm raised time = 2017-09-02 10:12:02 Location info = Cabinet No.=1, Subrack No.=4, Slot No.=2, Board Type=MRFU Cleared type = Normally cleared Cleared time = 2017-09-02 10:32:16 Special info = RAT_INFO=GUL, AFFECTED_RAT=GL, DID=NULL Special info1 = AF_G=231232_Airmadidi Atas_2G, AF_L=231232_Airmadidi_Atas_4G (Number of results = 24)