Professional Documents
Culture Documents
NL Corporation M3612-M3652-M3812-M3852 175w MV R40 Cylinder & Square Spec Sheet 10-75
NL Corporation M3612-M3652-M3812-M3852 175w MV R40 Cylinder & Square Spec Sheet 10-75
NL Corporation M3612-M3652-M3812-M3852 175w MV R40 Cylinder & Square Spec Sheet 10-75
Specify Voltage Required Clear and cold Alzak Available (See Price List)
Finish:
Conslruction:
Standard finlsh is #313 Duranodic Bronze Baked
Housings are constructed of heavy gauge aluminum
Enamel over chromate dip. Black, white, and satin
extruded material of corrosion resistant alloy with a
aluminum are also available. See price list.
1/8" wall th ic kness.
Pendants are supplied six feet o.a. with stem, Ballasl Type:
canopies, and alignment swivels. Constant wattage core and coil high power lactor
Socket and Wiring: autotransformer, easily accessible for service.
Fixture is wired wilh 200" C. SF2 Silicone wire and Labels:
n ickel-plated screw shell socket. Underwriters' listed, l.B.E.W. M
85
O COPYRIGHT OCT.1975, NL CORPORATION . 14901 BROADWAY, CLEVELAND, OHIO 44137
Certilied Test Report No. ERL 1390
NL Corp. Recessed oownlight, Cat. No.31'10
One GE Hl75BFL39-22 Mercury Lamp, Rated 5700 Lumens
Number of Luminaires Required for 30.0 and 70.0 FC. Candlepower Data Candlepower Summary
Light Loss Factor = .75 Angle Candlepower Lumens Angle Average CP
- See Footnote
CC, Wall + FC Belleclances = 80, 50, 20 0 5630 0 5630
Work Plane Height : 2.5 Feei 5 s071 480 5 5071
10 4324 10 4324
Room 30.0 Footcandles 70.0 Footcandles 15 3557 985 '15 3557
Dimensions Height Height 20 2461 20 2461
WL 8.s 10.0 13.0 16.0 8.5 10.0 13.0 16.0 1718 784 25 1718
20 20 666 7 14 14 15 16 30 a78 30 878
20 30 999 10 20 21 22 23 35 419 292 35 419
20 40 12 12 12 13 27 28 29 30 40 146 40 146
20 60 17 18 18 19 40 41 43 44 45 26 40 45 26
30 20 999 10 20 21 22 23 50 7
66
50 7
30 30 13 13 14 14 30 31 32 33 55 55 6
30 40 17 17 18 19 40 40 42 43 60 6
44
60 6
30 60 25 26 26 27 59 60 62 64 65 65 4
30 80 33 34 35 36 7A 79 A1 A4 70 2 70
75
2
75 1 1
40 20 12 12 12
'18 13 27 28 29 30
BO
1
0 BO 0
40 30 17 17 19 40 40 42 43 85 0 0 85 0
40 40 22 23 23 24 52 53 55 56 90 0
40 60 33 34 35 36 77 78 81 83
40 80 44 45 46 47 103 104 107 109 Tolal Output
40 100 55 55 57 58 124 129 132 136 Zone Lumens Percent
60 30 25 26 59 60 62 64 0-40 2540 44.57
60 40 33 34 7778U83 0-60 2586 45.38
60 60 49 50 51 52 115 116 119 1 21 0-70 2590 45.45
60 B0 67 67 69 1s5 154 157 160 0-90 2591 45.47
60 100 84 83 85 196 191 195 198 40-90 51 .90
100 40 55 s5 57 58 128 129 132 136 60-90 5 .09
100 60 ua2 83 85 196 191 195 198 70-90
90-180
1
0
.O2
100 B0 114 111 110 112 265 260 257 261 0.00
100 100 143 141 137 139 334 328 320 324 0-180 2591 45.47
For oiher light loss factors; Tested in Accordance with IES procedures.
No. of luminaires required = No. lrom iable X.75lNew LLF Test distance exceeds 25 feet.
M
86
O coPYFIGHT OCT. 1 975, N L CORPORATION . 14901 BFOACWAY, CLEVELAND, OHIO 44I 37