Standard Technical Features of BTG System for Supercritical 660/800 MW Thermal Units

iv) Pump HIS, ASTM, ASME or equivalent


design/
construction
code
v) No. of One working 2(1W*+1S) 2(1W+1S) 2(1W+1S)
pumps for each SG for each for each
plus one drain oil sump
common tank
standby
vi) No. of oil One working - - -
heaters for each SG
plus one
common
standby
vii) Capacity of To cater to To cater to 4 m3/hr 10 m3/hr
each pump 30% BMCR 7.5% BMCR
requirement requirement
of one steam of one steam
generator generator
without coal without coal
firing plus firing plus
10% 10%
viii) Pump considering considering considering -
suction zero tank zero tank zero tank
head level level level
ix) Pump To suit the To suit the 25 mlc 50 mlc
discharge requirements requirements (minimum) (minimum)
head of burners. of burners. or as or
required suiting site
to pump oil requirements
from drain to whichever is
main oil higher.
storage tank
@ 4m/hr,
whichever is
higher.
* One additional working pump for more than two units

9.2.3 The fuel oil pressuring pumps, LDO pressuring pumps and drain oil pumps
shall be rotary, positive displacement, horizontal type fitted with relief valves.

9.2.4 Heavy fuel oil heaters shall be:

i) Shell and tube type with oil through tubes (oil through shell is also
acceptable).

ii) Capacity of each heater shall be suitable for the rated capacity of each
heavy fuel oil pressurizing pump.