ROOFING -
‘The roof shall be covered with __(Specify brand) _ pre-pointed roofing sheets as shown on the
plans, The roofing sheets shall be secured to the purlins with 6mm dia. (1/4" dia) Gl rivets and Gavge
No. 26 plain GI straps cut long enough for bending around the specified size or purins. The straps shall
each be at least 25mm wide with corners chipped off at the riveting ends.
Ridge rolls, hip rolls and valleys to be used shall be those compatible with the __(Specily
brand)__ pre-painted long-spian roofing sheets. They shall lap the roofing sheets at least 250mm. The
ridge rolls, hip rolls and valleys shall be riveted to the roofing sheets, in addition to the rivets engaging the
‘Gl straps in securing the roofing sheets to the purtins.
All roofing sheets adjacent to concrete hollow block and other masonry walls such as at property
line firewalls, shall be provided with Gauge No. 26 plain GI flashing to extend up to the top and over to the
‘lher side of the wall. All rivets shall be placed at the top of the corrugations of the roofing sheets to
prevent water from standing around the rivets.
ELECTRICAL WORKS -
‘The electrical installation ‘shall be done in accordance with the approved plans andl under tha
direct superviston and control of a licensed Professional Electrical Engineer or Master Electrician.
‘All electric works and materials shall conform to the provisions of the latest edition of th
Philippine or National Electric Code.
‘The electrical wiring shall be installed thru __(Specify brand) coilable PVC electrical condul
fitings and appurtenances that conform with ISO dimensions.
“The type of electrical services to be supplied to the building shall be 220V, AC, single phase:
‘There shall be only one service drop from the nearest (Specify Electricity Company) pole to tht
proposed building. Electric wires far light and power shall not be smaller than 13,Smm* (AWG No. 12)
600V insulation,
Electrical materials to be used for the electric installation shall be as follows:
Automatic Circuit Breaker a..z. o-oo .. (Specify)
Flush wall switches, Convenience outlets other wiring devices ... (Specity)
Wires/Conductors 2 -(Specity)
(List other materials, if necessary)
empty PVC pipe, size 19mm 4 which should extend
‘The spare circuit shall be provided with an
19 wires shall be identified and all wires shall be cok
least 300mm above the ceiling line, The groundin
coded for easy identification.
‘The panelboard shall be provided with a circuit directory.
PLUMBING WORKS -
'AIL plumbing works for this project shall be done in accordance with the approved plans
under the direct supervision and control of a licensed Sanitary Engineer or Master Plumber.
Piping shall be property graded or pitched to ensure easy circulation, drainage and prevent wal
hammer and noise
39 ESTIMATING BILL OF MATERIALS - Tagayun