1. Tools

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2


Tools

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


2 Overview DBS3900 Outdoor

Door Closed Door Open

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


3 Overview DBS3900 Indoor

Cable duct

When power cable, grounding cable and transmission cable laying on the Wall, the cable must put
on the cable duct. Power cable and LAN cable must use different cable duct

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


3. Install base frame

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8
Crane handles replacement must install
plastic blocker bolt

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


4. Installation DCDU, SLPU, BBU3900, EMUA Position

Spare with Dummy

DCDU

SLPU

EMUA
BBU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


BBU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12
Installation BBU Cables

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


Installation CPRI cable at GTMU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


Installation CPRI cable at WBBP

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15


2. Installation Power Cable

Power Cable DBS to Rectifier. At Rectifier use MCB 80A or 63A


Power cable must use scun cable and Power cable must use scun cable
connect firmly and correcty
When Power cable came out from BTS to rectifier, the cable must use conduit protection

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17
Base frame view

CPRI and RRU power cable spare put in base frame cabinet

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18


C-Canal view

C-Canal must fixed to H-Beam or concrete foundation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19


Grounding
Outdoor

DCDU, SLPU, BBU must EMUA must grounding Inside cabinet grounding
grounding

All Grounding cabinet install to grounding bar with firmly and correctly,
and for outdoor installation when grounding cable came out from BTS
cabinet must use conduit protection

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20


Grounding indoor
Grounding Bar

Rectifier BTS

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21


RRU power cable grounding

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22


RRU Grounding

Grounding
Cable

RRU grounding must connect to bus bar with firmly


and correctly

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23


Antenna Installation

All bracket Antenna installation must


firmly and correctly

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24


Jumper routing must use water curve and jumper
must tie to mounting

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 25


SolutionRET Principle
Basic part of RET antenna system

RET antenna RCU :Remote Control AISG control cable


Unit
With Electrical Transmit control
Through adjust downtitl
adjustable downtitl signal and DC
angle when receive
function. Electrical signal ,drive the power supply for
For multi-band antenna, motor to change antenna RCU.
every band need to adjust downtitl angle to
downtitl angle. control/expand the
converge range.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


SolutionRCU Star Net

Star Net:
In this typical
configuration, the
antenna system
consists of the RET
antenna, SBT, RCU,

Star Net
and feeders. The AISG
port on the SBT is
connected to the RCU
through an AISG
control cable. the
AISG signal for each
RCU come from
different RRU. The
Net is simple and easy
to control.
too many SBT are
used.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27


SolutionRCU Chain Net

Chain Net:
Chain Net can be used
when the antennas for
three sectors are
installed on the same

Chain Net
pole or tower and
within a short distance
of each other. The AISG
signal for 3 RCU come
from the same port.
SBT can be saved in
Chain Net system.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 28


Overview RRU installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 29


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 30
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 31
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 32
RRU Position scenario 5

1. RRU install at Tray Vertical


2. RRU can install at tray vertical if RRU
cant install at mounting antenna and
leg of tower

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 33


RRU cant install at Tower Bracing

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 34


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 35
CPRI and Power RRU installation

When install CPRI cable and RRU power cable must put inside anaconda conduit from below of
cabinet until 1 m to vertical tray.
CPRI cable and RRU power cable must use different anaconda conduit

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 36


Conduit Protection Installation

1M

Conduit Protection install for CPRI and RRU power cable from tray horizontal until 1m to tray vertical,
make hole below conduit for water treatment.
Use separate conduit protection for CPRI and RRU power cable
All cable came out from BTS must use conduit protection

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 37


Standard Alarm installation for 2G

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 38


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 39
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 40
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 41
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 42
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 43
Standard Alarm installation for 3G

When at site only install 3G Stand alone so team must install ENVA alarm cable
from rectifier

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 44


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 45
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 46
Note : EMUA Monitoring signal cable connect to UPEU port Mon 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 47


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 48
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 49
Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 50


Label install at Jumper to antenna and Jumper to RRU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 51


Outdoor Label

Note :
W : White
R : Red
Y : Yellow
B : Blue

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 52


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 53
Indoor and Inside Cabinet Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 54


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 55
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 56
Com out to UPEU port 0 EMUA signaling cable to UEIU port 1

Grounding Cabinet to Bus


Bar

GTMU port FE0 to EM6T port 3

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 57


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 58
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 59
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 60
Thank you
www.huawei.com

You might also like