Leica - Configuratie Tehnica HistoCore Arcadia H+C - AC0031 EN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

DRAFT

Romania

Q U O T A T I O N AC0031 Date 15 / Sep / 2017


Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
HistoCore Arcadia H+C - Combined
Instrument

HistoCore Arcadia H+C - 220-240 V


Power cord Europe
Magnifier, assy.

HistoCore Arcadia H - Paraffin Dispenser

HistoCore Arcadia H - Basic Instrument


220-240 V - 50/60 Hz

HistoCore Arcadia H is an embedding station to


smooth the laboratory
workflow. The simple operation and the precise
control of this new
instrument helps to improve the quality,
reliability and speed of
embedding work. The new embedding station is
designed with the user in
mind. Because details matter, we added
comfortable armrests that
increase comfort
and stability, we improved the magnifier
(option) usability
to help embed small biopsies, and we added an
LCD touchscreen for
increased control and monitoring of the
instrument.
This reliable and easy to clean instrument
includes white and contrasted
LED illumination, a large hot working surface
holding up to 20 cassettes/molds and a paraffin
tank holding
Q U O T A T I O N AC0031 Date 15 / Sep / 2017
Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
up to 4 liters of paraffin, enough for a complete
day in most cases. A
pre-filter (option) can be used to pour melted
paraffin into the tank,
with the assurance that the paraffin is clean and
without particles. The
temperature of the different compartments and
surfaces of the instrument
can be adjusted individually with temperatures
between 50 C and 75 C,
in 1 C steps (can also be configured in
Fahrenheit).

Technical Data

General data

Voltage of power supply: 220-240 V AC,


50/60 Hz
Nominal current: 10 A max.
Protection class: 1
Pollution degree: 2
Overvoltage category: II
Operating temperatures:,,50 C to 75 C,
adjustable in 1 C increments

Operating environment

Environmental operating temperature: +20 C


to +30 C
Environmental operating relative humidity:
20 % to 80 % non-condensing
Environmental operating altitude: up to 2.000
m

Transport and storage environment

Transport temperature: -29 C to +50 C


Q U O T A T I O N AC0031 Date 15 / Sep / 2017
Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
Storage temperature: +5 C to +50 C
Transport and storage relative humidity: 10 %
to 85 % non-condensing (according to IEC-
1010, UL 3101, EN 61010)

Fuses

Time-lag fuses 5 x 20 mm, 2 x T10A, 250 V

Dimensions and weights:

Width ,,560 mm
Depth ,,600 mm
Height,,385 mm
Weight 25 kg

Capacities

Paraffin tank: Max. 4 L

Programmable parameters
Temperature:

Paraffin tank/dispenser
Embedding mold tray/cassette tray
Work surface/forceps holder

Time:

Working day, current weekday


Working times (start, end), current time

Standard delivery includes:


1 Basic instrument
Q U O T A T I O N AC0031 Date 15 / Sep / 2017
Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
2 Left/right tray, removable,,(14039353684),,
2 Lids for left/right trays (14039353720),,
1 Paraffin scraper (14039353643),,
1 Forceps holder, removable (14039355225),,
1 Paraffin tank filter (14039353559),,
4 Spare fuses, T10A (14600004975),,
1 IFU-Bundle HistoCore Arcadia H
(14039380001) consisting of:

1 Instructions for use HistoCore Arcadia H,


printed, DE/EN
1 CD including available languages
1 IFU-language order

HistoCore Arcadia C - Cold Plate

HistoCore Arcadia C - Basic Instrument


220-240 V - 50/60 Hz

HistoCore Arcadia C is a cold plate holding


more than
60 cassettes on its large working surface.
Cooling efficiency is important, so the cold
plate was
designed with an environment adaptive control
module to make sure the
operating temperature is always stabilized at -6
C. There is no need
to turn down the temperature in summer or
worry about too fast cooling
in winter.

Technical Data
Q U O T A T I O N AC0031 Date 15 / Sep / 2017
Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
General data

Voltage of power supply: 220-240 V AC,


50/60 Hz
Fuses: Time-lag fuses 5 x 20 mm, 2 x T10A,
250V
Nominal current: 5 A max.
Maximum start-up current(5 s): 25 A

Operating environment,,

Environmental operating temperature range:


+20 C to +30 C
Operating temperatures: -6 C
Environmental relative humidity: 20 to 80 %-
non-condensing
Environmental operating altitude: Up to 2000
m

Transport and storage environment ,,

Permissible temperature range during storage:


-29 C to +50 C
Permissible temperature range during
transport: +5 C to +50 C
Permissible humidity range during storage
and transport: 10 to 85 % - non-condensing
Electromagnetic environment: Basic
electromagnetic environment
IEC 61010 classification: Protection class 1
Pollution degree: 2
IP protection class (IEC 60529): IP20

Refrigeration unit

Refrigeration capacity*: 158 W( at 50Hz);


185 W( at 60Hz)
Q U O T A T I O N AC0031 Date 15 / Sep / 2017
Sales Person Mr. Alexandru Costoiu (+40 21 410 30 33)
alexandru.costoiu@medist-ls.ro

Description Total
EUR
Safety factor: 3
Refrigerant: R 134a
Compressor oil: 150 +10/-5 ml, Ester RL7H,
ISO 7
Coolant: 115 2 g *according to ASHRAE
condensing temperature: 54.4 C
evaporating temperature: -23.3 C ,,

Dimensions and weights

Width: 400 mm
Depth: 605 mm
Height: 385 mm
Weight: 30 kg

Standard delivery includes:

1 Basic instrument
4 Spare fuses, T5A (14600005015)
1 IFU-Bundle HistoCore Arcadia C
(14039381001) consisting of:

1 Instructions for use HistoCore Arcadia C,


printed, DE/EN
1 CD including available languages
1 IFU-language order

Power Cord various CEE 7/7 C13