Professional Documents
Culture Documents
Afico Brochure
Afico Brochure
Afico Brochure
Duct Liner
Product Code: ACOUSTICAL PERFORMANCE Density K-Value (at 24C)
DL 16 0.039
Density Thickness NRC
24 0.035
Kg/m3 mm
48 0.031
25 0.65
16 38 0.75
50 0.80 Facing: Black Glass Tissue (BGT)
25 0.75
24 38 0.90 APPLICATION AREAS
50 0.95 HVAC work
25 0.85
Perforated Suspended
Ceilings Studios
48 38 0.95
Auditorium Rooms
50 1.05 Generators Rooms
Blanket Insulation
Density : From 12 up to 56 kg/m3
Product Code: Thickness Thermal
K-Value : From 0.04 0.033 w/m.C
BKT Resistance(R)
Facing : Available unfaced or
mm in m2.C/W hr .ft2.F/Btu with (FRK facing) or
25 1 0.63 4
Aluminum Foil Glass
R-Values (for K-Values=0.04)
38 1 0.95 5
50 2 1.25 7
APPLICATION AREAS
64 2 1.60 9 Prefabricated Houses
75 3 1.88 11 Cavity Walls
Partitions
89 3 2.23 13 Poultry Farms
100 4 2.50 14 Backloading of Ceiling
Sandwich Panels
150 6 3.75 21
Board Insulation
Product Code: PRODUCT Thickness (T) THERMAL THERMAL
TYPE CONDUCTIVITY
BD BD (K-VALUE)
RESISTANCE
(R-VALUE)
pes mm in W/m.C Btu.in/ft2.hr.F m2.C/W hr.ft2.F/Btu.
Quiet Liner
Product Code: Acoustic Performance Density K-value
AQL Kg/m3 at 24C w/m.C
Density Thickness NRC
16 0.039
Kg/m3 mm
24 0.035
25 0.60
48 0.031
16 50 0.85
25 0.75
APPLICATION AREAS
24 50 0.95 HVAC work Studios
15 0.40 Sound Absorption Theatres
48 25 0.80 Treatment of Walls Auditoriums
Ceiling Generator Rooms
50 1.00
*Nominal Manufacturing Specifications. Check for availability of other dimensions and densities.
*The facings are also available with UL fire resistant rating.
Pre-Engineered Metal
Building Insulation
R-Values
38 1 0.95 5 in ft
89 3 2.23 13
100 4 2.50 14
150 6 3.75 21
Woven Facing
Product Code: Piping Fluid Runouts 25 32 64 125 200
AWF System Types Temperature up to & to to to &
Range C 50 under 50 100 150 over
Heating Systems Steam and
Minimum Insulation (mm) for pipe sizes
Hot Water: High Pressure/
Temperature Medium 152-238 40 64 64 75 89 89
Pressure/
Temperature Low Pressure/ 122-151 40 50 64 64 75 75
Temperature 94-121 25 40 40 50 50 50
Low Temperature Steam 49-93 13 25 25 40 40 40
Condensate
For Feed Water Cooling Any 25 25 40 50 50 50
Systems
Chilled Water Refrigerant, or 4.5-13 13 13 25 25 25 25
Brine Below 4.5 25 25 40 40 40 40
Saving energy for a clean environment
H.O. & Factory: P.O. Box 1289, Dammam 31431, Saudi Arabia
Tel: +966 3 847 2901 / 847 1519
Fax: +966 3 847 3605
E-mail: wajdei@afico.com.sa
Riyadh Office: P.O. Box 50281, Riyadh 11523, Saudi Arabia
Tel: +966 1 472 5555 ext. 283
Fax: +966 1 291 0162
E-mail: kathunaiyan@afico.com.sa
Jeddah Office: P.O. Box 2140, Jeddah 21451, Saudi Arabia
Tel: +966 2 670 0020 ext. 133
Fax: +966 2 287 2283
E-mail:
Gulf Regional Office: P.O. Box 44493, Deira, Dubai, U.A.E.
Tel: +971 4 294 1211
Fax: +971 4 294 1168
E-mail: aficogcc@emirates.net.ae
info@afico.com.sa www.afico.com.sa
Affiliate of Member of
OHSAS
18001
HE ALTH & SAFE TY
STAN DARD