175 PSIG
C A S T I R O N I N D U S T R I A L C O M P R E S S O R S
TECHNICAL DATA
DISPLACEMENT MAX. PRESSURE RPM MOTOR BELT MOTOR PULLEY OIL CAP. WEIGHT DISCHARGE
MODEL
cfm psig hp 2 POLES l IN QT. IN LBS SIZE
mm inch
MSV 40 MAX 40 175 1240 10 2-A 0.88 0.92 166 3/4" BSP
175 6.88
27 47
7 40 27 7
T2
46 T1 T2
42 28
T1
37
43 24
B
38 26
29
25
25
41
44 38 - 39
T3 T8 T3
24
B 25 T4 23
36
25
45 35 Position lbf.IN N.m
T3
34 22
T1 7 / 48 304 34
T1 48
5 T2 27 141 16
33 T3 LP-HP 24 / 36 19 2.2
5
A T4 LP 24 44 5
T1
3
32 21 T5 3 70 8
T5 48 T6 1 1128 127
30
20 T7 13 63 7.2
31 T8 41 149 17
11
19 TABLE 1 - TORQUE
T6 ESPECIFICATION FOR BOLTS
18
17
DETAIL OF THE
1 ASSEMBLY OF
2 GASKET IN A
4 CRANKCASE
5 6 1 8
9
A COVER
5 10 T7
1
12
13
14
T5
15
5
16 3
H
- Inspect the compressor visually.
- Check oil level and add some if necessary, before turning the
compressor on.
D - Drain moisture from the piping system.
C B F - Be sure there is no excessive or unusual vibration or noise.
WEEKLY
A E - Remove and clean intake air filters; do not wash the filter element.
A B C D E F G H - Check V-belts for tightness. Belt tension should be adjusted to allow
approximately 3/8" to 1/2" (9 to 13 mm) deflection with normal thumb
mm 435 75 220 10.5 500 200 580 410
pressure.
inch 17.1 3 8.7 0.41 19.7 7.9 22.8 16.1 - Clean cylinders externally, cylinder head, motor, fan blade, tubing, and tank.
- ASME safety valve should be tested manually to see if it is working properly.
INSTALLATION AND OPERATION INSTRUCTIONS MONTHLY
- Check entire system for air leakage around fittings, etc by using water and
INSTALLATION AND LOCATION soap lather.
1. Installation: Install the compressor in a covered, well - Check the pressure switch operation.
ventilated area, free of dust, toxic gases, humidity or any - Check for oil contamination and change it if necessary.
other kind of pollution. The compressor should be located no
QUARTERLY
closer than 32" (800mm) from a wall or any other obstacle
that could interfere with the air flow through the fan. This - Change the air filter element every 300 working hours or quarterly.
distance will also make maintenance easier. Place the (Whichever occurs first).
compressor on a leveled surface. Rotation of the flywheel - Fasten bolts and nuts as required (see Table 1).
must be in the direction of the arrow cast into the flywheel. - Change oil more frequently if compressor is located in a very dirty
The maximum ambient temperature recommended while environment.
working is 104F or 40C. If necessary, install an exhaust fan - WHILE RUNNING IN A PERIOD OF ABOUT 100 WORKING HOURS THE OIL
to guarantee fresh air and to dissipate heat. LEVEL SHOULD BE CAREFULLY CHECKED.
Before making the electrical connections, check oil level and
top-up lubricating oil. For type of oil, see table at the end of ANNUALLY
these instructions. - Test and calibrate the pressure switch, pressure gauge, pilot valve,
2. Electrical connection: The country's valid electrical discharge valve and ASME safety valve according to their own technical
standards must be followed regarding Low Voltage Electrical standards. These parts must be removed from the tank and pump to be
Installation. tested.
OPERATION - Inspect and clean the suction and discharge valve(s) plate(s) every 1000 (one
1. Initial start procedure: Before turning on the compressor, thousand) working hours (whichever occurs first), located between the
check the crankcase oil level. It must be in the middle of the cylinder and its cover and, if necessary, replace it (them) according to the
OIL LEVEL SIGHT or OIL LEVEL DISPSTICK. As to the type of operation conditions.
oil to be used and the recommended change intervals, check LUBRICATION
at "Lubrication" and as to its volume, check the Technical Data - The first oil change should be made after 8 hours of operation.
Table.
2. Start: Turn on the electrical start key and let your - The second oil change after 40 hours of operation.
compressor run for about 10 (ten) minutes, what will keep - The third and following exchanges should be made after 200 hours of
the tank's internal pressure or compressed air around 20 operation, or 60 (sixty) days, whichever occurs first.
psig. This will optimize a homogeneous lubrication of the NOTE:
parts. Heavy Duty and multi-viscous oils are not adequate for Schulz air
LIMITED WARRANTY compressor's lubrication. The same applies to oils that tend to emulsify.
We recommend good industrial oil for air compressors, with rust and
All component parts on your SCHULZ compressor are oxidation inhibitors and high viscosity level (from 90 to 95), SAE or ISO, as
warranted to be free of defects in workmanship and material indicated in the table below:
for a period of one year. Transportation charges are RECOMMENDED LUBRICANT OILS FOR SCHULZ AIR PUMPS
responsibility of the purchaser. This warranty extends to the
original purchaser of the compressor only. AMBIENT TEMPERATURE 0F (0C)
0
There are no express warranties except as contained in this Below 32 F 32 0F to 68 0F 68 0F to 104 0F
0 0 0 0 0
Below 0 C 0 C to 20 C 20 C to 40 C
limited warranty statement and implied warranties,
including those of merchantability and fitness for a particular SAE 10W SAE 20W SAE 30
or or or
purpose, are limited to the period of warranty. ISO 32 ISO 68 ISO 100
Our liability is limited solely to replacement of
nonconforming parts as set forth herein and does not include Note: Schulz reserves the right to make changes without prior notice.
any liability for any incidental, consequential, or other
damages of any kind. This warranty gives you specific legal DISTRIBUTOR
rights, and you may also have other rights that vary from
state to state.