Actual Free Air Discharge (P2-P1) V Po T: Coal Boiler Air Compressor Performance
Actual Free Air Discharge (P2-P1) V Po T: Coal Boiler Air Compressor Performance
(P2-P1) V
Q=
Po T
WHERE :
P2 = FINAL PRESSURE AFTER FILLING (KG/CM)
P1 = INITIAL PRESSURE AFTER BLEEDING (KG/CM)
Po = ATMOSPHERIC PRESSURE (KG/CM)
V = STOTRAGE VOLUME IN M (Reciver + a/f + Delivery pipe)
T = TIME TAKEN TO BUILT UP PRESSURE TO P2 IN MINT.
Pistion Displacement =
Theoretical compressor capacity = 35 CFM @ 9 bar
Compressed Rated RPM = 1440
Motor Rated RPM = 7.5 KW
Receiver Volume = 4
Additional hold up volume = 0.2
Total volume = 4.2
Q= 0.6472491909 m/min
m/min
m/min.
m/min.@ (kg/ cm)
m
m
m
Kg/ cm
Kg/ cm
Kg/ cm
m
min
22.97 CFM
Q design: 35 cfm