Professional Documents
Culture Documents
Training Manual A 319/320/321: ATA 24 Electrical Power
Training Manual A 319/320/321: ATA 24 Electrical Power
Training Manual A 319/320/321: ATA 24 Electrical Power
A 319/320/321
ATA 24
Electrical Power
Line & Base Maintenance
Page: i
TABLE OF FIGURES
Figure 1 AC/DC Power Sources - Location . . . . . . . . . . . . . . . . . . . 3 Figure 36 EGIU Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 2 Panels - Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 37 AC ESS Bus Supply Schematic . . . . . . . . . . . . . . . . . . . . 63
Figure 3 Electrical Power Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 38 CSM/G Engagement Logic . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 4 Electrical Power Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 39 RAT Extension and CSM/G Control Logic . . . . . . . . . . . 67
Figure 5 Electrical Power Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 40 CSM/G Control Schematic . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 6 Emergency Electrical Power Panel . . . . . . . . . . . . . . . . . . 13 Figure 41 EMER GCU - CFDS Utilization . . . . . . . . . . . . . . . . . . . . 71
Figure 7 Maint Bus Switch / External Power Panel . . . . . . . . . . . . . 15 Figure 42 CSM/G Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 8 ECAM ELEC Page - Description . . . . . . . . . . . . . . . . . . . . 16 Figure 43 Static Inverter Control Schematic . . . . . . . . . . . . . . . . . . . 75
Figure 9 ECAM ELEC Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 44 Galley Supply Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 10 ECAM ELEC Page - Description . . . . . . . . . . . . . . . . . . . 18 Figure 45 TR Unit Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 11 ECAM ELEC Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 46 TR Contactor Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Figure 12 Warnings/Inhibitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 47 TR-Unit - CFDS Utilization . . . . . . . . . . . . . . . . . . . . . . . . 85
Figure 13 Warnings/Inhibitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Figure 48 DC Tie Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 14 Basic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 49 DC ESS Bus normal Supply . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 15 Basic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 50 Battery Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 16 AC/DC Supply Configuration Chart . . . . . . . . . . . . . . . . . 26 Figure 51 BCL - CFDS Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 17 Basic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Figure 52 External Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Figure 18 AC/DC Supply Configuration Chart . . . . . . . . . . . . . . . . . 28 Figure 53 AC GEN - CFDS Utilization . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 19 Basic Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 54 Ground Service Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Figure 20 AC Control - Basic Schematic . . . . . . . . . . . . . . . . . . . . . 31 Figure 55 Load Distribution Schematic . . . . . . . . . . . . . . . . . . . . . . . 103
Figure 21 DC Control - Basic Schematic . . . . . . . . . . . . . . . . . . . . . 33
Figure 22 ELEC - ECAM/CFDS Communication . . . . . . . . . . . . . . 35
Figure 23 Components Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 24 Components Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 25 IDG Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 26 IDG Drive/Speed Conversion . . . . . . . . . . . . . . . . . . . . . . 43
Figure 27 IDG Oil System Schematic . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 28 IDG Control/Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 29 IDG Components Location . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 30 IDG Oil Cooler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Figure 31 APU Generator Location . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 32 IDG System Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 33 IDG System Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 34 APU Generator System Control . . . . . . . . . . . . . . . . . . . . 57
Figure 35 APU Generator System Control . . . . . . . . . . . . . . . . . . . . 59
Page: ii
Lufthansa Technical Training
ELECTRICAL POWER A319/320/321
GENERAL
24-00
DC Power Source
The DC electrical system is normally supplied from the AC electrical system via
Transformer Rectifiers.
PANEL DESCRIPTION
General
For Training Purposes Only
AC GEN
For Training Purposes Only
APU GEN FAULT lt is inhibited when APU speed is too low. OFF:
BUS TIE pb sw The main galley and secondary galley are not supplied.
AUTO: FAULT lt:
The bus tie contactors (BTC) open or close automatically in order to maintain Comes on amber accompanied by ECAM activation when the load of any gen-
erator is above 100 % of rated output.
power supply to both AC BUS 1 and 2.
One contactor is closed when:
- One engine generator supplies the associated AC BUS bar, and
- The APU GEN or EXT PWR supplies the other side.
3 4
2
For Training Purposes Only
Figure 12 Warnings/Inhibitions
FRA TS 84 wd 11.6.93 Seite: Page: 20
Lufthansa Technical Training
ELECTRICAL POWER A319/320/321
GENERAL
24-00
For Training Purposes Only
BCL
Figure 13 Warnings/Inhibitions
FRA TS 84 wd 11.6.93 Seite: Page: 21
Lufthansa Technical Training
ELECTRICAL POWER A319/320/321
GENERAL
24-00
AC BUSSES SUPPLY
AC BUS 1/2:
The supply of the AC BUSSES 1 and 2 and associated subbusses can be
done by one or separated by two of the AC power sources ( exception: external
power and APU generator cant supply the busses simultaneous.)
If there are several power supplies able to deliver correct voltage simultaneous,
the AC BUS 1 (2) are supplied in priority order as follows:
by the corresponding generator, GEN 1 (2)
by external power (EXT PWR)
by the APU generator (APU GEN)
or by the other generator, GEN 2 (1).
AC ESS BUSSES
Supply of important loads is provided by the AC ESS and AC ESS SHED
busses.
They are normally supplied by AC BUS 1 (AC ESS BUS CNTR 1 closed).
In the event of AC BUS 1 loss, AC ESS BUS and AC ESS SHED BUS can be
manually restored by the transfer of power supply directly from AC BUS 2.
In the event of AC BUS 1 and AC BUS 2 loss (emergency configuration), the
AC ESS BUS and AC ESS SHED BUS are restored automatically on the
CSM/G when the RAT hydraulic power is available.
In emergency configuration without CSM/G operation (it depends on the air-
craft configuration: speed, landing gear, RAT deployment time), the AC ESS
BUS is supplied by the static inverter (STAT INV), which is supplied by battery
1 (BAT 1). The AC ESS SHED BUS is no longer supplied.
AC STAT INV BUS
For Training Purposes Only
The static inverter bus (AC STAT INV) is directly supplied by the STAT INV, if
he is in operation.
This is the alternate supply for APU fuel pump, engine ignition and some impor-
tant annunciator lights.
TR1
TR2
For Training Purposes Only
DC ESS BUSSES
Essential DC loads are supplied by DC ESS BUS and DC ESS SHED BUS.
They are normally supplied by TR 1 via DC BUS 1 and DC BAT BUS (ESS DC
TIE CNTR is closed). For that the TR 2 must also be in operation.
If there is a loss of TR 1 and/or TR 2 the ESS TR takes over automatically the
supply of the DC ESS BUS and DC ESS SHED BUS.
For that the ESS TR is supplied by the AC ESS BUS (AC ESS EMER CNTR 1
is closed).
In emergency configuration or smoke configuration, when the EMER GEN is in
operation, the ESS TR is supplied by this generator. Without operation of the
EMER GEN, BAT 2 automatically takes over the supply of the DC ESS BUS
(STAT INV CNTR is closed). In the last case the DC ESS SHED BUS is no
longer supplied.
DC BAT BUS
The DC battery bus (DC BAT BUS) is normally supplied by TR 1 via DC BUS 1
For Training Purposes Only
TR1
TR2
For Training Purposes Only
<100kt
For Training Purposes Only
TR1
TR2
For Training Purposes Only
<100kt
For Training Purposes Only
TR1
TR2
For Training Purposes Only
AC CONTROL In accordance with the philosophy of the A 320, the pushbutton-switches have
to be in such a position, that all annunciator lights are extinguished when the
Three identical generator control units (GCU) are installed for the three genera- network is normal supplied.
tor systems (GEN 1, 2 and APU).
The control of the two bus tie contactors (BTC 1/2) happens automatically. It
The main functions of the GCUs are: depends on the position of the other contactors (GLC 1,2, APU and EPC).
to regulate the generator voltage by the field current. The BTCs can be switched off by one common pushbutton-switch (BUS TIE
to protect the network and the generator by control of the associated GLC OFF).
and the generator field current.
to provide BITE information to the GPCU. The supply of the AC ESS BUS takes place as follows:
to control the warnings associated with the corresponding channel. normally by the AC BUS 1 (automatic)
alternative by the AC BUS 2 (manually controlled by the AC ESS FEED pb-
For the CSM/G system a control unit (EMER GCU) enables full control. sw.)
The main functions of the EMER GCU are: in emergency configuration or smoke configuration by the EMER GEN or
to control the servo-valve excitation for speed regulation STAT INV in flight (automatically or manually).
to regulate the generator voltage by the field current
to protect the network and the generator by control of the associated GLC The centralized monitoring of the AC network happens via the ECAM system.
and the generator field current. Failure informations in detail are given via the CFDS.
For the external power system a ground power control unit (GPCU) serves:
to protect the network by control of the external power contactor (EPC)
to provide BITE information from external power and the three generator
systems (1, 2 and APU) to the CFDS.
For the emergency generator system one switch serve to manual control the
system in emergency configuration if necessary, and one switch to initialize an
operational test on ground (EMER GEN TEST).
Two spring-loaded switches are available to control the disconnect device of
the IDGs.
Annunciators integrated in the pushbutton switches show the condition of the
IDGs (drive part and generator), external power, essesntial supply, BTCs and
GLC 1.
DC CONTROL
The TRs (1, 2, ESS) supply their corresponding DC busses (1, 2, ESS)
through contactors, which are automatically controlled by the respective TR.
In case of a faulty TR the TR-contactor opens automatically and remains open
locked.
A RESET is possible either through the CFDIU via a MCDU, or through a RE-
SET pb-sw. on the relay-panel 103 VU in the right lateral avionics compart-
ment.
The contactors (DC TIE CNTR) between the DC busses (1, 2, ESS, BAT) are
controlled automatically through relais logics.
Two identical battery charge limiters (BCL) serve to control each battery con-
tactor when the corresponding BAT pb-sw. is in the AUTO position. The bat-
tery contactors connect the batteries with the BAT BUS.
The batteries are loaded via the BAT BUS normally through the TR 1, or supply
the BAT BUS if they are the only power supply.
Each BCL includes a BITE and self monitoring system which analyzes the
faults of the internal or peripheral information. Initiation of the test is possible
via the CFDS or at each power up on ground.
Each BCL delivers electrical parameters and warning concerning each battery
to the lower ECAM display unit.
In order to monitor the battery voltage without ECAM available there are two
digital DC volt-meters on the overhead panel. They are directly connected to
each battery via the DC HOT BUS and through a control C/B.
For Training Purposes Only
ELEC - ECAM/CFDS COMMUNICATION The parameters from the AC generation systems (1, 2, APU, EXT PWR) are
transmitted to the SDACs in digital via two elecrical generation interface units
ELEC - CFDS (EGIU).
The line and hangar maintenance of the electronic systems in the A 320/321 is The main functions of the EGIU is to process the parameters from the GCU
based on the use of the centralized fault display system (CFDS). and associated generator. The EGIU then transmits the information to the
The purpose of the CFDS is to give the maintenance personal a central main- cockpit (ECAM) via the SDACs.
tenance aid for trouble shooting. Two EGIUS are installed on the aircraft.
From the MCDUs it is possible: One EGIU is associated with the GCU 1 and GPCU. This EGIU receives pa-
to read the maintenance informations rameters in analog and discrete form from:
to initiate various tests. GEN 1 on channel 1 and
The electrical power components connected to the CFDS are as follows: external power on channel 2.
GPCU Each channel sends its own parameters to SDAC 1 and SDAC 2 through two
own isolated ARINC 429 data links.
BCL 1, 2
The second EGIU is connected in the same manner to generator 2 and to the
EMER GCU APU generator.
TR 1, 2, ESS
The GPCU and BCLs can memorize fault codes and communicate with the
CFDIU via ARINC 429 busses
The EMER GCU and the three TRs are connected to the CFDIU by a discrete
link: thus it is only possible to know these systems status (ok or faulty) during
SYSTEM REPORT/TEST sequence.
Note:
The GCU 1, 2 and APU are continuously monitored by the GPCU.
The GPCU stores in the memory the failure codes acquired by the GCUs.
The GPCU can then transmit to the CFDIU all the failure codes thus acquired
together with the failure codes from the GPCU and the external power system.
ELEC - ECAM
For Training Purposes Only
A
For Training Purposes Only
Contactor
(typical)
812
24-20 AC GENERATION
For Training Purposes Only
IDG - INTRODUCTION
Each engine (HP rotor) drives its associated main generator through the acces-
sory gearbox and via an integrated hydromechanical speed regulator which
transforms the engine variable speed into constant speed for the generator.
Thus the IDG provides a 400 Hz constant supply.
For Training Purposes Only
B IDG Attachment
For Training Purposes Only
B
Figure 25 IDG Location
FRA TS 84 wd 11.6.93 Seite: Page: 41
Lufthansa Technical Training
ELECTRICAL POWER A 320/A321
AC GENERATION
24-20
IDG DRIVE SPEED/CONVERSION The second machine (main exciter) receives its fields excitation from the pilot
exciter via the voltage regulator in the GCU to a 10 poles stator: this creates a
General stationary field. Rotating diodes rectify the three phase output of the main ex-
Each engine (HP rotor) drives its associated IDG through the accessory gear- citer rotor.
box. This output feeds the main rotor winding.
The IDG can be split into two parts: The third machine (main alternator) receives excitation for the rotating salient
four pole field from the rectified output of the main exciter.
the AC generator which has to be driven at constant speed to supply the
loads with constant frequency The main alternator has a three phase star connected stator winding. The three
phases and star point are taken to the generator output terminations.
the drive which transforms the engine variable speed into constant speed
for the generator. The generator is designed for use with an external voltage regulator forming
part of the GCU.
The unit is lubricated and cooled by an own oilsystem.
Drive Operation
A mechanical epicyclic differential gear transmits power to the generator por-
tion of the IDG (input speed: between 4500 and 9150 rpm; output speed:
12000 rpm constant).
The speed of mechanically coupled twin hydraulic sub-assemblies modify the
differential output speed. Each sub-assemblies consists of a hydraulic swash-
plate pump/motor: one with a fixed and the other with a variable swash angle.
The input shaft has a shear neck. Its primary duty is to protect the engine gear-
box. But it also serves to safeguard the IDG against further damage.
In case of abnormal function of the IDG drive part it is possible to disconnect
the IDG manually. Disconnection is irreversible in flight. The system can only
be rconnected on the ground with engines shut down.
Generator
The generator is a three stage machine with the three component machines
connected in cascade.
For Training Purposes Only
The first machine (pilot exciter) is a twelve pole permanent magnet generator
(PMG). The output from the PMG stator winding:
has a generator excitation function
provides power for other components of the electrical system of which the
generator forms part (supply of the GCU, EGIU and the external relays and
contactors). The generator is thus self-flashing and self-sufficient.
TO MPU
GCU
INPUT
SPEED
SENSOR
IDG OIL SYSTEM A quick fill coupling situated on the transmission casing enables pressure filling
or topping up the unit with oil.
The IDG has a self contained oil system except for the heat-exchanger. The oil thus introduced flows to the transmission via the scavenge filter and
Positive displacement scavenge pumps pump the oil (via the IDG filter) to the external cooler circuit. This ensures:
aircraft heat exchanger and return it to the IDG. the priming of the external circuit
The charge oil supply of cleaned, cooled deaerated oil is provided as a bus. the filtration of any oil introduced.
This oil supply feeds: An internal standpipe connected to an overflow drain ensures a correct quantity
the differential hydraulic units of oil.
the generator You can read the oil level through two sight glasses located on the IDG. One
the governor sight glass serves for the CFM 56 engine, the other one for the V 2500 engine.
the control piston
The lubrication jets are individually supplied. Oil temperature sensors monitor the temperature of both the input and output
The deaerator supercharges the inlet of the charge pump with solid oil. oil: they allow overheat detection.
The charge pump pressurizes the oil against the charge relief valve. A pressure switch operates in the event of a loss of the charge oil pressure.
It provides thus regulated supply pressures to: In both cases (overheat and loss of pressure) a warning is provided to the
the hydraulics cockpit.
the controls
the differential
the generator
the various lubrication and cooling nozzles
A differential pressure indicator is provided to show when the filter element is
clogged. The sensing device for the differential pressure is automatically sup-
pressed during cold oil running conditions: this avoids spurious operation due
to high oil viscosity.
Similarly, a cooler by-pass valve is fitted within the IDG.
The valve opens on a rising pressure to short circuit the cooler during cold oil
operation.
For Training Purposes Only
A scavenge pump relief valve limits the supply pressure of the scavenge sys-
tem.
A vent valve releases internal case pressure if necessary.
IDG CONTROL/INDICATION
Control and Indicating Circuits
The main parameters of the drive part of the IDG as:
oil in and oil out temperature
system pressure and
drive speed
are continuously monitored by the GCU.
All informations (normal and abnormal) which are necessary for the ECAM sys-
tem are acquired by the respective electrical generation interface unit (EGIU)
B
OIL DRAIN PLUG
Figure 31 APU Generator Location
FRA TS 84 wd 11.6.93 Seite: Page: 51
Lufthansa Technical Training
ELECTRICAL POWER A320/A321
AC GENERATION
24-20
trolled via the PRR (power ready relay) which is energized when: part is detectet,
the speed is greater than 4320 rpm and, FAULT light in the GALLEY pb-sw. and signal to ECAM via EGIU when
the GCR is closed. there is an overload condition with one generator,
Signals received or generated by the GCU control both these relays. FAULT light in the GEN pb-sw. and signal to ECAM via EGIU when a failure
in the generator system is detectet,
DISC indication on the ECAM SD when IDG DISC STATUS signal and IDG
DISC PB switch POS signal are both available,
IDG OIL OUT temperature on the ECAM SD,
GEN AC LOAD on the ECAM SD.
OC,
OC,
APU GENERATION SYSTEM CONTROL GCR and/or PRR are switched off by the following protection or control func-
tions:
General GEN pb-switch in OFF,
One generator control unit (GCU) serves for controlling and monitoring of the under-/overfrequency (UF/OF),
APU driven generator-system. under-/overvoltage (UV/OV),
Its functions are as follows: differential protection (DP),
regulation of the generator voltage shorted rotating diodes (SRD),
control and protection of the generator-system and network shorted PMG (SPMG),
control of various warnings and indications APU underspeed (US),
self-monitoring and test of the system (BITE). incorrect phase sequence (IPS),
Voltage Regulation computer failure
The voltage regulation is performed by regulating the generator excitation cur- Except for some particular cases the system may be resetted by setting GEN
rent: the voltage is kept at the nominal point of regulation ( POR ). pb-sw . to OFF than back to On.
The POR is located in the electrical power center at the end of the generator After a differential protection or GLC failure activation the system resetting can
feeder, upstream of the line contactor. only be performed two times via the GEN pb-sw. A further reset is possible via
Analog circuits achieve the regulation. the GCU (DP/BTC RESET).
The PMG provides directly the excitation supply via the generator control relay Warnings, Signalisations and Indications
( GCR ). The excitation supply is rectified. Then a chopper amplifier (pulse The GCU delivers the following outputs for warnings, signalisations and indica-
width modulation) controls the excitation supply. tions:
The regulation is achieved using a signal proportional to the average of the FAULT light in the GALLEY pb-sw. and signal to ECAM via EGIU when
three line to neutral voltages at the input. there is an overload condition with one generator,
Protection and Generator Control FAULT light in the GEN pb-sw. and signal to ECAM via EGIU when a failure
These functions mainly consists of generator excitation and generator line con- in the generator system is detectet,
tactor ( APU GLC) control. GEN AC LOAD on the ECAM SD.
The excitation is controlled via the GCR. The generator line contactor is con-
For Training Purposes Only
trolled via the PRR (power ready relay) which is energized when:
the speed is greater than 4320 rpm and,
the GCR is closed.
Signals received or generated by the GCU control both these relays.
FLOP
For Training Purposes Only
Alternate Supply
In the event of AC BUS 1 loss, the AC ESS BUS can be manually restored by
the transfer of power supply directly from the AC BUS 2 ( AC ESS BUS CON-
TACTOR 3XC-2 energized).
Condition:
AC BUS 2 supplied
AC ESS FEED pb-sw. in ALTN
all contactors, necessary to supply the AC ESS BUS by other busses or
power sources, must be deenergized.
Emergency Gen Supply
In the event of AC BUS 1 and AC BUS 2 loss (emergency configuration), the
AC ESS BUS is restored on the CSM/G, when the RAT hydraulic power is
available.
As soon as there is control power available from the EMER GCU, the relay
12XE is energized. Possibly still energized contactor (3XC-1 or 3XC-2) is
deenergized. Thereupon the EMER GLC (2XE) can be energized.
For Training Purposes Only
1 2
For Training Purposes Only
ALTN
(EMER GCU)
CSM/G ENGAGEMENT
Description
The extension of the Ram Air Turbine (RAT), for supplying the blue hydraulic
system in electrical emergency configuration, can be done via two solenoids.
The control of the solenoids is as follows:
Solenoid 1:
automatically dependent on the configuration of the electrical network and
aircraft
manually by operating of the HYD RAT MAN ON pb-sw. on the hydraulic
panel 40VU.
Solenoid 2:
manually by operating of the RAT & EMER GEN MAN ON pb-sw. on the
EMER ELEC PWR panel 21VU.
During the operational test of the CSM/G the above described control logic is
simulated by operating of the EMER GEN TEST pb-sw., without extension of
the RAT.
For Training Purposes Only
SAME AS A320
MLG NOT
COMPRESSED BLUE HYD
GND
For Training Purposes Only
SAME AS A320
AIR
A321 A320
Solenoid 2:
manually by operating of the RAT & EMER GEN MAN ON pb-sw. on the
EMER ELEC PWR panel 21VU.
During the operational test of the CSM/G the above described control logic is
simulated by operating of the EMER GEN TEST pb-sw., without extension of
the RAT.
For Training Purposes Only
BCL1
For Training Purposes Only
CSM/G CONTROL
The emergency generation system mainly consists of:
the Constant Speed Motor/Generator (CSM/G)
a Generator Control Unit (EMER GCU).
The CSM/G contains a hydraulic motor and an AC generator (emergency gen-
erator).
The hydraulic motor drives the generator. A servo valve speed regulator con-
trols the speed of the hydraulic motor.
It transforms the oil flow of the blue hydraulic system into a constant speed for
the emergency generator.
In emergency configuration the blue hydraulic system is pressurized by a Ram
Air Turbine (RAT).
Note: Normally the blue hydraulic system is supplied by an electrical pump
(normal electrical power configuration and during the CSM/G test).
The functions of the EMER GCU are:
control of the servo valve for the speed regulation of the CSM
voltage control of the emergency generator
protection of the generator system
control of the solenoid valve for the hydraulic supply of the CSM.
There are three modes to get the EMER GEN into operation:
automatically dependent on the configuration of the electrical network and
aircraft (AUTO CSM/G CONTROL LOGIC)
manually by operating of the RAT & EMER GEN MAN ON pb-sw.
manually by operating of the EMER GEN TEST pb-sw. (push and hold).
For Training Purposes Only
In the first two cases the starting of the CSM/G is only possible with nose land-
ing gear up and locked (relay 3PH deenergized).
As soon as the generator system is power ready, control power for the corre-
sponding contactors is available from the GLC CONTROL CKT.
The EMER GCU (type 3 system) can be tested through the CFDIU via the
MCDU.
AUTO
EMER GCU
The FAULT light in the GALLEY pb-sw. illuminates, when one of the three gen-
erator sytems (IDG 1,2 or APU) signals an overload condition (discrete from
the GCU).
When there is an overload condition with the APU generator system during
ground operation, the complete galley loads are automatically switched off
(relay 4XA is energized and locked via the GALLEY pb-sw.).
A reset of the galley loads is possible via the GALLEY pb-sw. (first OFF than
on again).
For Training Purposes Only
24-30 DC GENERATION
For Training Purposes Only
TR-UNIT
Each Transformer Rectifier Unit (TR) is supplied with 115 V AC/ 400 Hz, three
phase.
Its nominal current output is 200 A at a voltage of 28 V DC.
The TRs are switched to the corresponding DC busses via contactors, which
are controlled by the TRs itself.
In case of overheat ( >171 C) or minimum current detection ( < 1 A), the TR
contactor is switched off and locked open via the latching relay K 1.
For TR 2 an open latching of the contactor after minimum current detection is
inhibited during ground service operation (contactor 3PX energized).
RESET of a TR is possible either via the CFDS or a common RESET pb-sw.
(15PU) on the relay panel 103VU in the middle right avionics compartment.
Parameters of voltage and current of a TR are delivered to the ECAM system
by the TR and are displayed on the system display (SD).
For Training Purposes Only
TR2 ONLY
(GRD SERV.OPER.)
For Training Purposes Only
TR
For Training Purposes Only
DC TIE CONTROL
DC TIE CNTR 1 (1PC1) Control
The contactor is normally energized and serves for connecting the DC BAT
BUS to the DC BUS 1.
The FINs in the logic in detail stand for the following components:
1PC1 = DC TIE CNTR 1
1PC2 = DC TIE CNTR 2
4PC = ESS DC TIE CNTR
3PE = ESS TR CNTR
1PP = DC BUS 1
5PU1 = TR 1 CNTR
For Training Purposes Only
BATTERY CONTROL In flight, when the electrical emergency configuration is initiated, the APU
start sequence is inhibited during 45 seconds (CNTR 5KA inhibited).
General If the CSM/G comes on line before 45 sec., the APU start sequence is
Two Ni-Cd batteries are installed as DC power sources. Each of them has a available as soon as the CSM/G is coupled to the network.
capacity of 23 Ah. The APU start sequence is also inhibited in emergency configuration, when
They are used for: the landing gear is extended.
start of the APU on ground and in flight, or After a battery or BCL failure, or after battery voltage < 22 V, the battery
contactor opens and remain latched open. A reset is possible by pushing
supplying parts of the AC/DC network in emergency configuration, during the appropriate BAT pb-sw. to OFF and back to AUTO.
RAT deployment and when the emergency generator is not in operation
(configuration with landing gear down). The EMER GEN FAULT light on the EMER ELEC PWR panel is contrlled by
BCL 1 and 2. It illuminates, when:
- AC BUS 1 and 2 power loss
Control - nose landing gear up and locked
Each battery system contains a battery charge limiter (BCL), which controls the - ESS TR CNTR (3PE) not energized.
corresponding battery contactor (BC). Therefor the BAT pb-sw. (cockpit over- All parameters of the batteries for ECAM (indications and failure messages)
head panel) must be in pos. AUTO (pressed in): are delivered by the BCLs in digital form.
BC (BAT CNTR) 1 (2) closed, when: All failure messages from the BITEs (including static inverter fault) are de-
- battery voltage < 26,5 V and BAT BUS voltage > 27 V, or livered to the CFDIU in digital form.
- APU start (APU master switch ON and APU speed < 95%), or
- no AC power available (AC BUS 1 and 2 power loss) and A/C on ground
(LGCIU) or A/C speed < 100 kts (ADIRU 1).
BC 1 (2) open, when:
- charge current < 4 A (BAT SHUNT),or
- charge current rate > 0,4 A/min. during a charge current between 10 A
and 200 A (thermal runaway) (BAT SHUNT), or
- charge current > 150 A for > 90 sec. (BAT SHUNT), or
- discharge current > 150 A (BAT SHUNT), or
For Training Purposes Only
5KA
For Training Purposes Only
GENERAL
AC BUS 1 and AC BUS 2 are supplied by external power, when the EPC and
BTC 1 and 2 are energized.
Controls for the external power system are in the cockpit on the overhead
panel and on the ground control panel.
CONTROL CIRCUITS
Energizing of the EPC depends on correct voltage from the external power unit
(EPU). It is checked by the ground power control unit (GPCU).
The control power is available, when the power ready (PR) circuit is energized
in the GPCU.
It is delivered via:
EGIU 1 (channel 2, EXT PWR CTL circuit) and
EPC AUX CTL RLY (5XG) and
a control circuit consisting of aux. contacts of GLCs and BTCs (GLC.BTC
LOGIC).
INDICATING CIRCUITS
As soon as the external power unit delivers correct voltage at the receptacle,
the AVAIL light in the EXT PWR pb-sw. and the EXT PWR AVAIL light on the
receptacle panel illuminate.
After energizing the EPC the AVAIL light in the switch extinguishes and the ON
light illuminates.
The EXT PWR NOT IN USE light on the receptacle panel illuminates, when
neither the EPC nor the AC GND SPLY CNTOR (12XX) is energized.
For Training Purposes Only
4.
Verteiler:
Page: iii