Professional Documents
Culture Documents
Pro 787426
Pro 787426
Technical data
Technical data
Technical information
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
ATEX-certified cylinders can be generated in the Internet configurator.
ATEX ID: II 2G c IIB T4 II 2D c IP65 T125C X
The operating temperature range for ATEX-certified cylinders is -20 C ... 50 C .
Technical information
Material
Dimensions
Dimensions
S = stroke
Dimensions
L2 L3 0,5 L8 RT SW TG VA -1 VD WH
16.25 4.5 940,4 M6 10 32,50,5 4 5 261,4
18.25 4.5 1050,7 M6 13 380,5 4 5 301,4
25 4.5 1060,7 M8 17 46,50,6 4 5 371,4
25 4.5 1210,8 M8 17 56,50,7 4 5 371,8
33 0 1280,8 M10 22 720,7 4 5 461,8
36 0 1381 M10 22 890,7 4 5 511,8
45 0 1601 M12 27 1101,1 6 7 652,2
Seite 4 | AVENTICS
Diagrams
Cushioning diagram
Accessories overview
Overview drawing
NOTE:
This overview drawing is only for orientation to see where the various accessory parts can be fastened to the cylinder.