August 10,2010 ECG
Scope of Work
Address: 6315 Woodbury Ave., Las Vegas, NV 89103
Specs listed by trade
Trade: 22 Plumbing
• Pertorm full leak detection inspection
o Assess any extra leak problems in home
o Remedy any existing water damage
• Water heater:
o Repair/install double wall (B-Vent) through building cavity
• Maintain I" Clearance to drywall and combustible materials
• Use fire-rated caulk to seal B-Vent flange to drywall
o Insulate exposed hot and cold water pipes with foam pipe insulation (R-4)
• Ensure 3' space between single wall vent pipe. Use correct Diameter of
insulation sleeve so it fits tightiy.
• Seal at wall penetrations
o Rebuild water heater platform
o Install sediment trap on gas line to water heater
o Install metal vent collar (to provide I" min clearance from combustibles). Seal all gaps and
penetrations,
• Install low-flow faucet aerators <1.5 gpm
• Install low-flow kitchen faucet aerators 2.2 gpm max
• Install low-flow EPA WaterSense approved faucets <1.5 gpm (approx. 4)
• Install low-flow EPA WaterSense approved toilets (1.28 gpD
• Laundry hook-ups: Install washing machine outiet box and replace both angle stops with metal
washing machine shut off valve
• Caulk all showers, baths, countertops and vinyl areas
Trade:• 23Replace
Electric. all existing incandescent bulbs including Halogen GU-10 with CFL's inside and out
• Electrical Panel: Consolidate circuit breakers or upgrade panel to provide two full size breaker
spaces
• Install arc fault breakers for bedrooms
• Install/Repair GFCI receptacles per code
Install GFCI at roof top unit
lace missing or broken switches nd
Provide qp<llnstal ex aust only mechanical ventilation with 5' reflective flex duct (R-8)
cV)/Bnted to outside in upstairs bathroom (NOT MASTERS)
¥ Panasonic Whisper Green (42 CFM continuous)
• ep ace cel mg an s WI nergy ar mo e WI
o 50' Fanimation Edgewood White Energy Star Ceiling Fan with light kit and 00457
Fanimation C-2-3 Wire White Fan/Light Wall Control. Provide Ecosmart 14W Soft White
lamps. (size for room according to manufacturer)
• Replace exterior lights with motion activated lights
o Seal around top and sides leave bottom open to allow for drainage.
---_
.~~~-----------------
. ~~~---=~~--------
Trade: 25 Appliances
o Provide and install refrigerator
to?J 5 J
{).))o hUjLu.•.
- ~- (]
JJJ
o Whirlpool, side by side, 25.1 Cu Ft, Model # ED8VHEXVB (color Black)
o Provide and install dishwasher
o Whirlpool 24 in Built-In, Model # DU1345XTVB (color Black)
• Provide and Install washer
o Whirlpool 4.0 Cu F. Frontload, Model #WFW9150WW (COlor White)
• Provide and install Gas Range with
o Vented microwave hood min 120cfm and all hook ups
o Whirlpool 30 in, Model # WFG114SVB (color Black)
o Install New gas flex line
• Provide and install dryer
o Whirlpool, Gas, 6.7 Cu Ft Model #WGD9150WW (color White)
o ENSURE proper venting
o Replace backdraft damper
o Install new gas flex line.
Trade: 4 Site Work
o Clean up and trim all landscaping. Replace any dead plants in front yard. Spray for weeds
• Front yard: Remove dead grass, cap all unused irrigation and install 'I." rock ,()It ~~ 2,,"'1e;!<'1-0
• Install pressure vacuum breakers a minimum of 12 inches above all downstream piping
• Retrofit irrigation to include drip emitters, a filter, a pressure regulator, rain sensor and timer
• Repair outside water leaks if found at their source
o See soil moisture at west side yard ~ Mifbor
o Repair damage to stucco k~ \J..., tum 7
o Repair exterior utility boxes to ensure weatherproof closure . if (.
o Remove all security bars from windows, repair exterior security doors. Patch stucco as necessary. ~sa- St>,,(Ij, p.!'1V''''''
o Replace wood under stucco arches at front of house? ~,,~c-e.;,
Trade: 19 Paint & Wallpaper
• Drywall Patch all holes on interior surfaces
o Texture to match
o Paint interior of home once patCh is complete
o Paint all exterior building surfaces
o Paint garage
Trade: 10 Carpentry
• Complete replacement of kitchen. Cabinet, sink, disposal, countertop, etc.
Trade: 800 DoorslWindows/Glass
o Replace all interior doors, hinges and hardware
• Replace minrored closet doors
o Install a one hour (20 min is code) fire-rated solid core door and frame to garage with seW-closing
hinge (1-3/8" to 1-3/4' x 32x80)
o After demo of laundry room
• Replace exterior front entry door and frame with Energy Star rated insulated metal panel door (R-
6.5 r greater). No windows. Install sealed peep hole
• Replace eXls Ing Wln ows and install Double Low-E VinyVComposite windows
(U=0.30/SHGC=0.30) or lower
o Include the sliding door
o Leave labels on windows
arage 'door opener for proper operation
Trade: 21)iVAC
5'80 ~eplace existing HVAC system and install a 3-TON. 15 Seer RTU unit as supported by the Manual
~~ace exisMg fumace with 73 BTU, 80 AFUE gas RTU unit as supported by Manual J& S
~;; 0
15 Roofing
Repair damage to roof
• Check roof "ashin at fireplace
rade: 16~nservatlon
0"9
As
j.l..-
fL ~C\ ••..., g ~
b "1
....(
all ceiling penetrations (p umbing, electrical, mechanical, framing) at attic and interior walls.
S LJ
0educe pir leakage of the building shell to 750 CFM 50 f-
lY" Begin air sealing largest holes and attic by passes, e.g. gaps around supplies and returns 'Z! .
_ ~ first floor
V Seal all connections to the attic (highest) from the attic where possible e.g recessed
cans, supply and return boots, smoke detectors, light fIXtUres,electrical and plumbing in,,,,
• ~rywall and top plates, seams in top plates. IT
I,( Seal voids where plumbing penetrate walls, e.g. shower heads, toilets, under sinks,
• Acessed clothes washer and ice box
V Seal hole sin interior finishes, around door frames/jambs, at strike plates, stairs,
• ,)hermostat(s), medicine cabinets, etc
V ;>eal sill plates and fireplace
\J,/Seal exterior penetrations e.g. cable wire, holes in stucco, around doors, door bell,
• ftctrical outlets/switches, wall connections with garage, etc
-
V Seal all outdoor light fixtures to wall. Leave bottom of fixture unsealed to allow for
• Alrainage
!( )l\'eatherstrip doors
Vse, .
f ftf-1'" I> •
Remove prior sealing techniques and ensure window opening.
f'/b • Remove existing fiberglass batt insulation and dispose of proper1y
• Increase attic insulation to R.50 (min) with blown cellulose bury ducts
i1--~12-
Trade: 20 Floor Coverings Il-,(I z...
• Remove carpet from garage floor and dispose of proper1y ('Lt.I,! (.,
• Replace carpet in ENTIRE HOME
o Install FHA approved, plush carpet over a 1/2' medium density re.bond pad w/ a ,2x'S ~
minimum of seams. Stretch carpet to eliminate puckers, scallops & ripples. Include
tackless strips, metal edge strips, and mending tape to cover entire floor including closets.
o Seal around base plate before reinstallation
Trade: 24 Extermination
• PEST SPRAY 1
o Spray interior and exterior for bugs.
MISCELANIOUS
• Repair bath hall vanity 3() w 4/k
I' ~f ) Sp/QI-- cr;-. (lf1i' kdl
111A~ b4. '(;ara S'ftd. tn-- !.ei-f--