Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

@l

HOUSING OUR
HOUSINGFOR COMMUNITIES,
NEVADA -:;64f j~Nvt(A!6o
August 10,2010 ECG
Scope of Work
Address: 6315 Woodbury Ave., Las Vegas, NV 89103
Specs listed by trade
Trade: 22 Plumbing
• Pertorm full leak detection inspection
o Assess any extra leak problems in home
o Remedy any existing water damage
• Water heater:
o Repair/install double wall (B-Vent) through building cavity
• Maintain I" Clearance to drywall and combustible materials
• Use fire-rated caulk to seal B-Vent flange to drywall
o Insulate exposed hot and cold water pipes with foam pipe insulation (R-4)
• Ensure 3' space between single wall vent pipe. Use correct Diameter of
insulation sleeve so it fits tightiy.
• Seal at wall penetrations
o Rebuild water heater platform
o Install sediment trap on gas line to water heater
o Install metal vent collar (to provide I" min clearance from combustibles). Seal all gaps and

penetrations,
• Install low-flow faucet aerators <1.5 gpm
• Install low-flow kitchen faucet aerators 2.2 gpm max
• Install low-flow EPA WaterSense approved faucets <1.5 gpm (approx. 4)
• Install low-flow EPA WaterSense approved toilets (1.28 gpD
• Laundry hook-ups: Install washing machine outiet box and replace both angle stops with metal
washing machine shut off valve
• Caulk all showers, baths, countertops and vinyl areas
Trade:• 23Replace
Electric. all existing incandescent bulbs including Halogen GU-10 with CFL's inside and out
• Electrical Panel: Consolidate circuit breakers or upgrade panel to provide two full size breaker

spaces
• Install arc fault breakers for bedrooms
• Install/Repair GFCI receptacles per code
Install GFCI at roof top unit
lace missing or broken switches nd
Provide qp<llnstal ex aust only mechanical ventilation with 5' reflective flex duct (R-8)
cV)/Bnted to outside in upstairs bathroom (NOT MASTERS)
¥ Panasonic Whisper Green (42 CFM continuous)
• ep ace cel mg an s WI nergy ar mo e WI
o 50' Fanimation Edgewood White Energy Star Ceiling Fan with light kit and 00457
Fanimation C-2-3 Wire White Fan/Light Wall Control. Provide Ecosmart 14W Soft White
lamps. (size for room according to manufacturer)
• Replace exterior lights with motion activated lights
o Seal around top and sides leave bottom open to allow for drainage.
---_
.~~~-----------------
. ~~~---=~~--------
Trade: 25 Appliances
o Provide and install refrigerator
to?J 5 J
{).))o hUjLu.•.
- ~- (]
JJJ
o Whirlpool, side by side, 25.1 Cu Ft, Model # ED8VHEXVB (color Black)
o Provide and install dishwasher
o Whirlpool 24 in Built-In, Model # DU1345XTVB (color Black)
• Provide and Install washer
o Whirlpool 4.0 Cu F. Frontload, Model #WFW9150WW (COlor White)
• Provide and install Gas Range with
o Vented microwave hood min 120cfm and all hook ups
o Whirlpool 30 in, Model # WFG114SVB (color Black)
o Install New gas flex line
• Provide and install dryer
o Whirlpool, Gas, 6.7 Cu Ft Model #WGD9150WW (color White)
o ENSURE proper venting
o Replace backdraft damper
o Install new gas flex line.
Trade: 4 Site Work
o Clean up and trim all landscaping. Replace any dead plants in front yard. Spray for weeds
• Front yard: Remove dead grass, cap all unused irrigation and install 'I." rock ,()It ~~ 2,,"'1e;!<'1-0
• Install pressure vacuum breakers a minimum of 12 inches above all downstream piping
• Retrofit irrigation to include drip emitters, a filter, a pressure regulator, rain sensor and timer
• Repair outside water leaks if found at their source
o See soil moisture at west side yard ~ Mifbor
o Repair damage to stucco k~ \J..., tum 7
o Repair exterior utility boxes to ensure weatherproof closure . if (.
o Remove all security bars from windows, repair exterior security doors. Patch stucco as necessary. ~sa- St>,,(Ij, p.!'1V''''''
o Replace wood under stucco arches at front of house? ~,,~c-e.;,
Trade: 19 Paint & Wallpaper
• Drywall Patch all holes on interior surfaces
o Texture to match
o Paint interior of home once patCh is complete
o Paint all exterior building surfaces
o Paint garage
Trade: 10 Carpentry
• Complete replacement of kitchen. Cabinet, sink, disposal, countertop, etc.
Trade: 800 DoorslWindows/Glass
o Replace all interior doors, hinges and hardware
• Replace minrored closet doors
o Install a one hour (20 min is code) fire-rated solid core door and frame to garage with seW-closing
hinge (1-3/8" to 1-3/4' x 32x80)
o After demo of laundry room
• Replace exterior front entry door and frame with Energy Star rated insulated metal panel door (R-
6.5 r greater). No windows. Install sealed peep hole
• Replace eXls Ing Wln ows and install Double Low-E VinyVComposite windows
(U=0.30/SHGC=0.30) or lower
o Include the sliding door
o Leave labels on windows
arage 'door opener for proper operation
Trade: 21)iVAC
5'80 ~eplace existing HVAC system and install a 3-TON. 15 Seer RTU unit as supported by the Manual

~~ace exisMg fumace with 73 BTU, 80 AFUE gas RTU unit as supported by Manual J& S

Ne.... ~)-f c-I.•...b 'P f ~"-S ("'SlJ.CJeI


/ h 215ti»OD6Mf
~ 3 IV" Install new R.8 ducts & Insulate ducts to R-20 by burying all ducts possible in 8" min of blown ~
;:ettrilose
V Install new optimized duct design (based ACCA Manual D), minimize duct length, configure ducts
'-2J
at floor ~ttic to be buried in attic insulation
. /" ¥ Drop ducts to floor of attic and bury under cellulose
V Replace)l1C Filters
. fVMERV8
V Seal Ducts to S 6% (Leakage to Outside)
o Seal where line sets penetrate evap coil and where evap COilconnects to supply plenum
o Seal all boot to drywall connection
o Mechanically fasten and mastic all connections per Home Performance Specification for
Warm Climates
ve all supply and return grilles and seal boot to drywall with mastic, caulk or gun foam
all and program thermostat{s)
nstall transfer grills above bedroom doors
Use OBD su I Ie 7

~;; 0
15 Roofing
Repair damage to roof
• Check roof "ashin at fireplace
rade: 16~nservatlon
0"9
As
j.l..-
fL ~C\ ••..., g ~
b "1
....(

all ceiling penetrations (p umbing, electrical, mechanical, framing) at attic and interior walls.
S LJ
0educe pir leakage of the building shell to 750 CFM 50 f-
lY" Begin air sealing largest holes and attic by passes, e.g. gaps around supplies and returns 'Z! .
_ ~ first floor
V Seal all connections to the attic (highest) from the attic where possible e.g recessed
cans, supply and return boots, smoke detectors, light fIXtUres,electrical and plumbing in,,,,
• ~rywall and top plates, seams in top plates. IT
I,( Seal voids where plumbing penetrate walls, e.g. shower heads, toilets, under sinks,
• Acessed clothes washer and ice box
V Seal hole sin interior finishes, around door frames/jambs, at strike plates, stairs,
• ,)hermostat(s), medicine cabinets, etc
V ;>eal sill plates and fireplace
\J,/Seal exterior penetrations e.g. cable wire, holes in stucco, around doors, door bell,
• ftctrical outlets/switches, wall connections with garage, etc
-
V Seal all outdoor light fixtures to wall. Leave bottom of fixture unsealed to allow for
• Alrainage
!( )l\'eatherstrip doors
Vse, .
f ftf-1'" I> •
Remove prior sealing techniques and ensure window opening.
f'/b • Remove existing fiberglass batt insulation and dispose of proper1y
• Increase attic insulation to R.50 (min) with blown cellulose bury ducts
i1--~12-
Trade: 20 Floor Coverings Il-,(I z...
• Remove carpet from garage floor and dispose of proper1y ('Lt.I,! (.,
• Replace carpet in ENTIRE HOME
o Install FHA approved, plush carpet over a 1/2' medium density re.bond pad w/ a ,2x'S ~
minimum of seams. Stretch carpet to eliminate puckers, scallops & ripples. Include
tackless strips, metal edge strips, and mending tape to cover entire floor including closets.
o Seal around base plate before reinstallation
Trade: 24 Extermination
• PEST SPRAY 1
o Spray interior and exterior for bugs.
MISCELANIOUS
• Repair bath hall vanity 3() w 4/k
I' ~f ) Sp/QI-- cr;-. (lf1i' kdl
111A~ b4. '(;ara S'ftd. tn-- !.ei-f--
868£96£ : 01