Variasi Laju Alir Fluida Dingin

Saat laju alir aliran dingin 5 LPM

Densitas air dingin = 0,997 Kg/L


Densitas air panas = 0,99556 Kg/L
Cp = 4184 J/Kg.K
A = 2.441664 m2

Perhitungan Q laju aliran fluida dingin

m = Laju Alir aliran air dingin x massa jenis air


= 0,0833 L/s x 0,997 kg/L
= 0,08 kg/s

Qc = m x Cp x T
= 0,08 kg/s x 4184 J/Kg K x 6 K
= 2086,2 J/s
Perhitungan Q laju aliran fluida panas
m = Laju Alir aliran air panas x massa jenis air
= 0,133 L/s x 0,995 kg/L
= 0,13 kg/s

Qh = m x Cp x T
= 0,13 kg/s x 4184 J/Kg K x 6 K
= 3332,3 J/s
Perhitungan Q laju aliran fluida steam
m = 0,004 Kg/s
Laju alir steam = m/p
= 0,004 Kg/s / 0,997 Kg/L
= 0,004 L/s
Qh = m x Cp x T
= 0,004 kg/s x 4184 J/Kg K x 8,2 K
= 135,9 J/s
Perhitungan U laju aliran fluida dingin

Y =

2822
= 3322

= 0,55


Z =

3327
= 2822

=1
Didapat Ft pada kurva adalah 0,7

T1 = Thi Tco
T1 = 33 28
T1 = 5

T2 = Tho Tci
T2 = 28 22
T2 = 6

1 2
=

1
2

56
=
5
6
= 5,484815

Tm = FT . Tlm

Tm =0,7 . 5,484815
Tm = 3,83937

=
.

2086,2 /
=
2,44 2 3,83937

= 296,4272 Wm-2K-1
Perhitungan efisiensi
n = Qc/Qh x 100%
= 2086,2/3332,3 x 100%
= 62,61%

Variasi Laju Alir Fluida Panas

Saat laju alir aliran panas 6 LPM

Densitas air dingin = 0,997 Kg/L


Densitas air panas = 0,99556 Kg/L
Cp = 4184 J/Kg.K
A = 2.441664 m2

Perhitungan Q laju aliran fluida dingin

m = Laju Alir aliran air dingin x massa jenis air


= 0,133333 L/s x 0,997 kg/L
= 0,13 kg/s

Qc = m x Cp x T
= 0,13 kg/s x 4184 J/Kg K x 3 K
= 1669 J/s
Perhitungan Q laju aliran fluida panas
m = Laju Alir aliran air panas x massa jenis air
= 0,1 L/s x 0,995 kg/L
= 0,0995 kg/s

Qh = m x Cp x T
= 0,0995 kg/s x 4184 J/Kg K x 10 K
= 4165,4 J/s
Perhitungan Q laju aliran fluida steam
m = 0,004 Kg/s
Laju alir steam = m/p
= 0,004 Kg/s / 0,997 Kg/L
= 0,004 L/s
Qs = m x Cp x T
= 0,004 kg/s x 4184 J/Kg K x 8,2 K
= 135,9 J/s

Perhitungan U laju aliran fluida panas



Y =

2522
= 3422

= 0,25


Z =

3424
= 2522

= 3,33
Didapat Ft pada kurva adalah 0,52

T1 = Thi Tco
T1 = 34 25
T1 = 9

T2 = Tho Tci
T2 = 24 22
T2 = 2

1 2
=

1
2

92
=
9
2
= 4,654016
Tm = FT . Tlm

Tm =0,52 . 4,654016
Tm = 2,420088

=
.

4165,4 /
=
2,44 2 2,420088

= 705,40 Wm-2K-1

Perhitungan efisiensi
n = Qc/Qh x 100%
= 1669,0/4165,4 x 100%
= 40,0671%

Variasi Laju Alir Fluida Steam

Saat laju alir aliran steam 0,4545 LPM

Densitas air dingin = 0,997 Kg/L


Densitas air panas = 0,99556 Kg/L
Cp = 4184 J/Kg.K
A = 2.441664 m2

Perhitungan Q laju aliran fluida dingin

m = Laju Alir aliran air dingin x massa jenis air


= 0,125 L/s x 0,997 kg/L
= 0,13 kg/s

Qc = m x Cp x T
= 0,13 kg/s x 4184 J/Kg K x 5 K
= 2607,8 J/s
Perhitungan Q laju aliran fluida panas
m = Laju Alir aliran air panas x massa jenis air
= 0,133333 L/s x 0,995 kg/L
= 0,13 kg/s

Qh = m x Cp x T
= 0,13 kg/s x 4184 J/Kg K x 20 K
= 11107,8 J/s
Perhitungan Q laju aliran fluida steam
m = 0,0075 Kg/s
Laju alir steam = m/p
= 0,0075 Kg/s / 0,997 Kg/L
= 0,0075 L/s
Qs = m x Cp x T
= 0,0075kg/s x 4184 J/Kg K x 34 K
= 1075,455 J/s

Perhitungan U laju aliran fluida steam



Y =

2722
= 4622

= 0,208333


Z =

4626
= 2722

=4
Didapat Ft pada kurva adalah 0,6

T1 = Thi Tco
T1 = 46 27
T1 = 19

T2 = Tho Tci
T2 = 26 22
T2 = 4
1 2
=

1
2

19 4
=
19
4
= 9,627

Tm = FT . Tlm

Tm =0,6 . 9,627
Tm = 5,78

=
.

1075,455 /
=
2,44 2 5,78

= 76,31Wm-2K-1

Perhitungan efisiensi
n = Qc/Qh x 100%
= 2607,8/ 11107,8 x 100%
= 23,48%