Serial-COM1 Brocade SW 10 10

You might also like

Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 1685

INIT: version 2.

78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

INIT: version 2.78 booting


Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Thu Sep 8 15:11:39 2016
The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...


CPLD: Reseting Bridge...
ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.
The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,
DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...


*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Mon Oct 10 11:59:41 2016
The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active
Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.
[7]: Thu Sep 8 15:27:44 2016
Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 12:10:56 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.
[5]: Thu Sep 8 15:15:23 2016
Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.
Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Thu Sep 8 15:09:58 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========
-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...
Fabric parameters (yes, y, no, n): [no]
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.
2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is
enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.
[4]: Thu Sep 8 15:15:23 2016
The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect
DS_6510B_Secondary_2 login: root
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...
Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Thu Sep 8 15:09:58 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...


*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root
Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS


Hit ESC to stop autoboot: 0
Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,
INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Mon Oct 10 12:13:04 2016
The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.
[6]: Thu Sep 8 15:27:32 2016
Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...


Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged
out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Thu Sep 8 15:11:39 2016
The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:


Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.
INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)


CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:


Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)


CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.
[7]: Thu Sep 8 15:27:44 2016
Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS


Hit ESC to stop autoboot: 0
Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure
Not all options will be available on an enabled switch.
To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.
[5]: Thu Sep 8 15:15:23 2016
Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)


CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14


Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Thu Sep 8 15:11:39 2016
The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...


CPLD: Reseting Bridge...
ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.
The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,
DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0
.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 12:10:56 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.
[4]: Thu Sep 8 15:15:23 2016
The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow
SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,
INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.
Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.
Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========
-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.
The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay
Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:


Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.
Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 12:10:56 2016
Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...


The system is going down for system halt NOW !!
INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.
[4]: Thu Sep 8 15:15:23 2016
The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect
DS_6510B_Secondary_2 login: root
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************
wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Thu Sep 8 15:09:58 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.
Changing password for root
Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,
INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...


*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14


Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,
INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Mon Oct 10 12:13:04 2016
The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.
[5]: Thu Sep 8 15:15:23 2016
Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.
Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.
Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:


Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...
CPLD: Reseting Bridge...
Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3


Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...
Security Policy, Password or Account Attribute Change: AdmUserREM will be logged
out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!
This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...


U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:


Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)


CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b
WARNING: Firmwaredownload is in progress.
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...
Fabric parameters (yes, y, no, n): [no]
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:
set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.
2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is
enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure
Not all options will be available on an enabled switch.
To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.
[5]: Thu Sep 8 15:15:23 2016
Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow
SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,
DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 11:57:48 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS


Hit ESC to stop autoboot: 0
Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 12:10:56 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Thu Sep 8 15:11:39 2016
The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...


CPLD: Reseting Bridge...
ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.
The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,
DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...


*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 11:57:48 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...
CPLD: Reseting Bridge...
Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Thu Sep 8 15:09:58 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: root
fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...


*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hdaINIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
[2]: Mon Oct 10 11:57:48 2016
Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...
CPLD: Reseting Bridge...
Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0
.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,


INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.
[3]: Mon Oct 10 11:59:41 2016
The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback
Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889287; sup_qid: 0
2016/10/10-10:57:16, [HAM-1004], 54, CHASSIS, INFO, DS_6510B, Processor rebooted -
Reset.
.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-10:57:30, [FV-1001], 55, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-10:57:43, [FCR-1069], 56, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-10:57:43, [FCR-1068], 57, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-10:57:44, [ZONE-1022], 58, FID 128, INFO, DS_6510B_Secondary_2, The
effective configuration has changed to EMC_VNX_5400_Main. .
2016/10/10-10:57:44, [FV-1002], 59, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-10:57:44, [MFIC-1002], 60, FID 128, INFO, DS_6510B_Secondary_2, Chassis
FRU header not programmed for switch NID, using defaults (applies only to FICON
environments).
Oct 10 10:57:46 All service instances on Active
POST1: Started running Mon Oct 10 10:57:50 GMT 2016
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Mon Oct 10 10:58:09 GMT 2016 took
(0:0:19)
POST2: Started running Mon Oct 10 10:58:10 GMT 2016
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Mon Oct 10 10:58:43 GMT 2016 took
(0:0:33)
2016/10/10-10:58:44, [BL-1000], 61, CHASSIS, INFO, DS_6510B, Initializing ports...
2016/10/10-10:58:44, [BL-1001], 62, CHASSIS, INFO, DS_6510B, Port initialization
completed.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> enable exec
DS_6510B_Secondary_2:root> enable execlogin
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> exec
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> enable
enable .
enable :
enable [
enable alias
enable bg
enable bind
enable break
enable builtin
enable cd
enable command
enable compgen
enable complete
enable continue
enable declare
enable dirs
enable disown
enable echo
enable enable
enable eval
enable exec
enable execlogin
enable exit
enable export
enable false
enable fc
enable fg
enable getopts
enable hash
enable help
enable history
enable jobs
enable kill
enable let
enable local
enable login
enable logout
enable popd
enable printf
enable pushd
enable pwd
enable read
enable readonly
enable return
enable shift
enable shopt
enable source
enable suspend
enable test
enable times
enable trap
enable true
enable type
enable typeset
enable ulimit
enable umask
enable unalias
enable unset
enable wait
DS_6510B_Secondary_2:root> configure
configure configurechassis
DS_6510B_Secondary_2:root> configure ?
Usage: configure
DS_6510B_Secondary_2:root> configure terminal
Usage: configure
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configure

Not all options will be available on an enabled switch.


To disable the switch, use the "switchDisable" command.

Configure...

Fabric parameters (yes, y, no, n): [no]


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> subStorage -e
sh: subStorage: command not found
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbStorage -e
sh: usbStorage: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> version
Kernel: 2.6.14.2
Fabric OS: v7.2.0a
Made on: Mon Sep 9 17:08:27 2013
Flash: Thu Sep 8 15:06:10 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwarestatus
sh: firmwarestatus: command not found
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.2.0a
v7.2.0a
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Thu Sep 8 15:03:04 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Thu Sep 8 15:09:58 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Thu Sep 8 15:11:39 2016


The firmware commit operation has started. This may take up to 10 minutes.

[4]: Thu Sep 8 15:15:23 2016


The commit operation has completed successfully.

[5]: Thu Sep 8 15:15:23 2016


Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.

[6]: Thu Sep 8 15:27:32 2016


Firmwarerestore is entered. System will reboot and a firmware commit operation will
start upon boot up.

[7]: Thu Sep 8 15:27:44 2016


Unable to restore the secondary partition. Please use firmwaredownloadstatus and
firmwareshow to see firmware status.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddress
sh: ipaddress: command not found
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features

DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.240.130.8
Ethernet Subnetmask: 255.255.255.240
Gateway IP Address: 10.248.130.14
DHCP: Off
DS_6510B_Secondary_2:root> usbstorage -e
Trying to enable USB device. Please wait...
sda: assuming drive cache: write through
sda: assuming drive cache: write through
Fail to enable USB storage device. Error:Device is not found or not formatted
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> usbstorage -l
Failed to list the files: USB device not enabled.
DS_6510B_Secondary_2:root> ipaddrset
Ethernet IP Address [10.240.130.8]:10.77.77.77
Ethernet Subnetmask [255.255.255.240]:255.255.255.0
Gateway IP Address [10.248.130.14]:10.77.77.1
DHCP [Off]:
IP address is being changed...Done.
2016/10/10-11:33:41, [IPAD-1000], 63, CHASSIS, INFO, DS_6510B, SW/0 Ether/0 IPv4
manual 10.77.77.77/24 DHCP Off.
2016/10/10-11:33:41, [IPAD-1001], 64, CHASSIS, INFO, DS_6510B, CP/0 IPv4 manual
10.77.77.1 DHCP Off.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ipaddrshow

SWITCH
Ethernet IP Address: 10.77.77.77
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 10.77.77.1
DHCP: Off
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-11:35:46, [SEC-1193], 65, FID 128, INFO,
DS_6510B_Secondary_2, Security violation: Login failure attempt via TELNET/SSH/RSH.
IP Addr: 10.77.77.111.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> pwd root
/root
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
flow Configure Flow Vision services
fmmonitor Configure Frame Monitors
fosconfig Enable/disable FabOS services
fosexec Invoke command in alternate VF context
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
fwalarmsfilterset Configure alarms filtering for Fabric Watch
fwalarmsfiltershow Show alarms filtering for Fabric Watch
fwclassinit Initialize all Fabric Watch classes
fwconfigreload Reload Fabric Watch configuration
fwfrucfg Configure FRU state and notification
fwhelp Print Fabric Watch help info
fwmailcfg Configure Fabric Watch Email Alert
fwportdetailshow Create a report with detailed port information
fwsamshow Show availability monitor information
fwset Set port persistence time
fwsettocustom Set boundary & alarm level to custom
fwsettodefault Set boundary & alarm level to default
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
iscsihelp Print iSCSI help info
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Configure MAPS features
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS features
mapsdb Configure MAPS features
mapshelp Display all MAPS commands
mapspolicy Configure MAPS features
mapsrule Configure MAPS features
mapssam Display port times
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
perfaddeemonitor Add end-to-end monitor
perfcfgclear Clear Performance settings from FLASH
perfcfgrestore Restore Performance configuration from FLASH
perfcfgsave Save Performance configuration to FLASH
perfclearalpacrc Clears the CRC error count associated with a port
and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor Clears statistics counters of one or more
end-to-end performance monitors.
perfdeleemonitor Delete end-to-end monitor
perfhelp Print Performance Monitoring help info
perfmonitorclear Clear end-to-end/filter-based/ISL monitors
perfmonitorshow Show end-to-end/filter-based/ISL monitors
perfresourceshow Show monitor availability
perfsetporteemask Set overall mask for end-to-end monitors
perfshowalpacrc Get ALPA CRC count by port and ALPA
perfshoweemonitor Show user-defined end-to-end monitors
perfshowporteemask Show the current end-to-end mask
perfttmon Configure bandwidth usage monitor
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgfportbuffers Configure F_Port buffers
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portfencing Configure Fabric Watch port fencing feature
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
portthconfig Configure Fabric Watch port threshold monitor
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
saschiptest Functional Test of Components in SAS Complex.
saspathtest Data Path Test of the SAS complex.
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchstatuspolicyset Set policy parameters for overall switch status
switchstatuspolicyshow Print policy parameters for overall switch status
switchstatusshow Print overall switch status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysmonitor Configure system memory usage monitor
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
thconfig Configure Fabric Watch thresholds
thmonitor Configure Fabric Watch threshold monitors
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trackchangeshelp Print Track Changes help info
trackchangesset Configure alert for login/logout/config update
trackchangesshow Displays status of track changes
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root> passwd root

Warning: Access to the Root and Factory accounts may be required for
proper support of the switch. Please ensure the Root and Factory
passwords are documented in a secure location. Recovery of a lost Root
or Factory password will result in fabric downtime.

Changing password for root


Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root> 2016/10/10-11:37:47, [SEC-1203], 66, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root> 2016/10/10-11:38:42, [SULB-1001], 67, CHASSIS, WARNING,


DS_6510B, Firmwaredownload command has started. (From v7.2.0a To v7.2.1g).
2016/10/10-11:43:44, [SULB-1044], 68, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-11:43:53, [FSSM-1002], 69, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:44:00, [FSSM-1003], 70, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:44:02, [RAS-1007], 71, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Nov 4 2015 - 11:26:25)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x19be60
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4290075 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3211397 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293889341; sup_qid: 0

.
Loopback Replay
2016/10/10-11:44:34, [HAM-1004], 72, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:44:48, [FV-1001], 73, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:45:13, [FSSM-1002], 74, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 79
Oct 10 11:45:18 All service instances on Active
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:45:21, [SULB-1003], 75, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
2016/10/10-11:45:22, [FV-1002], 76, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Validating the filesystem ...
Mon Oct 10 11:47:56 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 11:49:00 2016: Firmware commit completed successfully.
2016/10/10-11:49:00, [SULB-1004], 77, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-11:49:00, [SULB-1036], 78, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.2.1g.
2016/10/10-11:49:00, [SULB-1002], 79, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login:

Fabric OS (DS_6510B_Secondary_2)
DS_6510B_Secondary_2 console login: 2016/10/10-11:50:07, [SEC-1193], 80, FID 128,
INFO, DS_6510B_Secondary_2, Security violation: Login failure attempt via
TELNET/SSH/RSH. IP Addr: 10.77.77.111.
2016/10/10-11:50:35, [SEC-1203], 81, FID 128, INFO, DS_6510B_Secondary_2, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 10.77.77.111
2016/10/10-11:51:24, [SULB-1001], 82, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.2.1g To v7.3.2b).
2016/10/10-11:57:48, [SULB-1044], 83, CHASSIS, INFO, DS_6510B, Firmwaredownload to
secondary partition has completed successfully.
Loopback Backup (hda2:hda1)
Start loopback
All service instances in sync
2016/10/10-11:57:57, [FSSM-1002], 84, CHASSIS, INFO, DS_6510B, HA State is in sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-11:58:04, [FSSM-1003], 85, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-11:58:06, [RAS-1007], 86, CHASSIS, INFO, DS_6510B, System is about to
reboot.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Aug 23 2016 - 16:13:09)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0xac46f
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
GLIBC detected first boot after install.
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...

sys_chip_init: class 0 max 24 Done


ethsw_ha_enabled = 1
uptime: 4293890143; sup_qid: 0
Loopback Replay

Start loopback
.
2016/10/10-11:58:52, [HAM-1004], 87, CHASSIS, INFO, DS_6510B, Processor rebooted -
FirmwareDownload.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-11:59:00, [FV-1001], 88, CHASSIS,


INFO, DS_6510B_Secondary_2, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
All service instances in sync
2016/10/10-11:59:31, [FSSM-1002], 89, CHASSIS, INFO, DS_6510B, HA State is in sync.
FSSLO: HCL time: 93
2016/10/10-11:59:37, [FV-1002], 90, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
Oct 10 11:59:38 All service instances on Active
Service instances out of sync
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-11:59:40, [FSSM-1003], 91, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-11:59:41, [SULB-1003], 92, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
Validating the filesystem ...

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fiPassword:
2016/10/10-12:00:00, [SEC-1192], 93, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via SERIAL.
Login incorrect

DS_6510B_Secondary_2 login: root


Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 11:51:24 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:01:53, [SEC-1203], 94, FID 128, INFO,


DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111
firmwaredownloadstatus

[1]: Mon Oct 10 11:51:24 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 11:57:48 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 11:59:41 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
v7.2.1g

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> Mon Oct 10 12:02:30 2016: Doing firmwarecommit now.
Please wait ...

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.3.2b
Unknown

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:03:38 2016: Firmware commit completed
successfully.
2016/10/10-12:03:38, [SULB-1004], 95, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:03:38, [SULB-1036], 96, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.3.2b.
2016/10/10-12:03:38, [SULB-1002], 97, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.
2016/10/10-12:04:45, [SULB-1001], 98, CHASSIS, WARNING, DS_6510B, Firmwaredownload
command has started. (From v7.3.2b To v7.4.1d).

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

DS_6510B_Secondary_2:root> 2016/10/10-12:10:56, [SULB-1044], 99, CHASSIS, INFO,


DS_6510B, Firmwaredownload to secondary partition has completed successfully.
Loopback Backup (hda1:hda2)
Start loopback
All service instances in sync
2016/10/10-12:11:05, [FSSM-1002], 100, CHASSIS, INFO, DS_6510B, HA State is in
sync.
Block ASIC Reset For Warm Reboot
Service instances out of sync
2016/10/10-12:11:12, [FSSM-1003], 101, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
ki_state_set: redundant DEACTIVATE for instance 1
2016/10/10-12:11:14, [RAS-1007], 102, CHASSIS, INFO, DS_6510B, System is about to
reload.
Restarting system.

The system is coming up, please wait...

U-Boot 1.1.3 (Jul 13 2016 - 10:48:01)

CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Stinger
I2C: ready
DRAM: Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 54
wr_dqs_shift = 95
dll_dqs_delay_X = 29
dll_dqs_delay_X window = 3 - 56
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1d006100
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM... DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Stinger CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x02...

CPLD: Reseting Bridge...


Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01 00 1657 001d 0280 1a
00 07 10b5 8112 0604 18
In: serial
Out: serial
Err: serial
Net:

set_bootstatus: BS_LOAD_OS, platform_idx = 14

Type run flash_nfs to mount root filesystem over NFS

Hit ESC to stop autoboot: 0


Map file at LBA sector 0x1b6310
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (uncompressed)
Data Size: 4306459 Bytes = 4.1 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 3227782 Bytes = 3.1 MB
Image 1: 1078663 Bytes = 1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to
0x00C00000
## initrd at 0x007140D4 ... 0x0081B65A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
GLIBC detected first boot after install.

INIT: version 2.78 booting


Bypassing firmware validation.

INIT: Entering runlevel: 3

Starting Fabric OS Services...


FIPS off, RRD...
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293890231; sup_qid: 0
.
Loopback Replay
Start loopback

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: 2016/10/10-12:12:05, [HAM-1004], 103, CHASSIS,


INFO, DS_6510B, Processor rebooted - FirmwareDownload.
2016/10/10-12:12:12, [FV-1001], 104, CHASSIS, INFO, DS_6510B_Secondary_2, Flow
Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.

Fabric OS (DS_6510B_Secondary_2)

DS_6510B_Secondary_2 console login: root


fibranne
Password:
===================================================================================
=========
ATTENTION:
It is recommended that you change the default passwords for all the switch
accounts.
Refer to the product release notes and administrators guide if you need further
information.
===================================================================================
=========

-----------------------------------------------------------------
Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts
that are intended for diagnostics and debugging purposes solely by
the Equipment vendor's trained engineers. Improper use of the
functionality made available through the Root or Factory account could
cause significant harm and disruption to the operation of the SAN fabric.

Your use of the functionality made available through the Root or Factory
account is at your sole risk and you assume all liability resulting from
such use. The Equipment vendor shall have no liability for any losses
or damages arising from or relating to the use of the Root or Factory
account (and the functionality enabled thereby) by anyone other than
the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> versioFSSLO: HCL time: 106
n
Kernel: 2.6.14.2
Fabric OS: v7.4.1d
Made on: Thu Jul 14 23:11:53 2016
Flash: Mon Oct 10 12:07:30 2016
BootProm: 1.0.11
DS_6510B_Secondary_2:root> All service instances in sync
2016/10/10-12:12:55, [FSSM-1002], 105, CHASSIS, INFO, DS_6510B, HA State is in
sync.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredService instances out of sync
oOct 10 12:12:59 All service instances on Active

Broadcast message from root Mon Oct 10 12:12:59 2016...

*******************************************
Notice: System has changed state to active.
All active commands are available now.
*******************************************

wnloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

2016/10/10-12:12:55, [RAS-2001], 106, CHASSIS, INFO, DS_6510B, Audit message log is


enabled.
2016/10/10-12:12:59, [FV-1002], 107, FID 128, INFO, DS_6510B_Secondary_2, Flow
Vision Config Replay Completed Successfully.
2016/10/10-12:12:59, [FSSM-1003], 108, CHASSIS, WARNING, DS_6510B, HA State out of
sync.
2016/10/10-12:13:01, [MAPS-1201], 109, FID 128, INFO, DS_6510B_Secondary_2, MAPS
has started monitoring with dflt_base_policy policy.
ki_state_set: redundant ACTIVATE for instance 1
2016/10/10-12:13:05, [SULB-1003], 110, CHASSIS, INFO, DS_6510B, Firmwarecommit has
started.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Validating the filesystem ...
firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwaredownloadstatus
[1]: Mon Oct 10 12:04:45 2016
Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:13:40, [SEC-1203], 111, FID 128, INFO,
DS_6510B_Secondary_2, Login information: Login successful via TELNET/SSH/RSH. IP
Addr: 10.77.77.111

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwaredownloadstatus

[1]: Mon Oct 10 12:04:45 2016


Firmware is being downloaded to the switch. This step may take up to 30 minutes.

[2]: Mon Oct 10 12:10:56 2016


Firmware has been downloaded to the secondary partition of the switch.

[3]: Mon Oct 10 12:13:04 2016


The firmware commit operation has started. This may take up to 10 minutes.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.3.2b

WARNING: Firmwaredownload is in progress.


DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> Mon Oct 10 12:15:46 2016: Doing firmwarecommit now.
Please wait ...
Mon Oct 10 12:16:55 2016: Firmware commit completed successfully.
2016/10/10-12:16:55, [SULB-1004], 112, CHASSIS, INFO, DS_6510B, Firmwarecommit has
completed.
2016/10/10-12:16:55, [SULB-1036], 113, CHASSIS, INFO, DS_6510B, The new Version:
Fabric OS v7.4.1d.
2016/10/10-12:16:55, [SULB-1002], 114, CHASSIS, INFO, DS_6510B, Firmwaredownload
command has completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v7.4.1d
v7.4.1d
DS_6510B_Secondary_2:root> help
aaaconfig Configure RADIUS for AAA services
ad Specifies all administration domain (AD)-level
operations
ag Configure the Access Gateway feature
agautomapbalance Configure the Access Gateway automapbalance feature
agshow Displays the Access Gateway information registered
with the fabric
aliadd Add a member to a zone alias
alicreate Create a zone alias
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
auditdump Display audit log
authutil Get and set authentication configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
bladecfggemode Configure 1GigE/10GigE port configuration for blade
bladedisable Disables all user ports on a blade.
bladeenable Enables all User Ports on a blade.
bladeswap Swaps area numbers for all ports on a blade
bootluncfg Configure boot LUN for an HBA
bottleneckmon Configure port bottleneck monitor
bpportloopbacktest Functional test of port via blade processor path.
bpturboramtest MBIST test for AP blade BP ASICs
burninerrclear Clear errors that are stored in the non-volatile
storage
burninerrshow Display errors that are stored in the non-volatile
storage
burninlevel Set diagnostics level
burninstatus Display the diagnostics burnin status.
ceeportledtest Cycle user port LEDs.
ceeportloopbacktest Functional test of port N->N path.
ceeturboramtest MBIST test for ASICs
cfgactvshow Display Effective zone configuration information
cfgadd Add a member to a configuration
cfgclear Clear all zone configurations
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
cfgenable Enable a zone configuration
cfgremove Remove a member from a configuration
cfgsave Save zone configurations in flash
cfgshow Print zone configuration information
cfgsize Print size details of zone database
cfgtransabort Abort zone configuration transaction
cfgtransshow Print zone configurations in transaction buffer
chassisbeacon Set chassis beacon on or off
chassiscfgperrthreshold Configure parity error threshold
chassisdisable Disable all ports in chassis
chassisdistribute Distributes data to physical chassis in a fabric
chassisenable Enable all ports in chassis
chassisname Display or set the chassis's Name
chassisshow Display all Field Replaceable Units (FRU)
classconfig Display RBAC class permissions
clihistory Displays a log of most recently executed CLI
commands
cmsh Start CEE Management Shell
configdefault Reset config to factory default
configdownload Load switch config from a server
configlist List the stored config files
configremove Remove a stored config file
configremoveall Removes all configuration data from switch
configshow Print switch config parameters
configupload Save switch config to a server
configure Set logical switch config parameters
configurechassis Set chassis config parameters
creditrecovmode Configure backend credit loss recovery
cryptocfg Configure encryption node functions
datatypeshow Display available diagnostic data types.
date Print/set the system date and time
dbgshow Display debug levels of various modules
defzone Activates or deactivates a default zone
configuration.
diagclearerror Clears diagnostics failure status.
diagdisablepost Disable diagnostic POST.
diagenablepost Enable diagnostic POST.
diaghelp Display diagnostic command descriptions.
diagpost Displays the contents of port registers and
memories.
diagretry Sets diagnostic retry mode
diagsetcycle Set diagnostic script parameters.
diagshow Display diagnostic status.
diagstatus Display currently running diagnostic tests.
distribute Distributes data to switches in a fabric.
dlsreset Configure dynamic load sharing (DLS) option
dlsset Configure dynamic load sharing (DLS) option
dlsshow Display the state of the dynamic load sharing
option
dnsconfig Configure DNS service
enclosureshow Display the switch enclosure attributes
errclear Clear error log
errdelimiterset Sets the error log start and end delimiter for
messages sent to the console and syslog
errdump Print error log (no page breaks)
errfilterset Sets a filter for an error log destination
errmoduleshow Displays all the defined modules in the system
errshow Print error log
ethif Display the Usage of the ethif command
extncfg Configure blade/switch extension product features
fabportshow Display contents of a particular port's data
fabretryshow Display retry count of various fabric commands
fabretrystats Display retry count of fabric SW_ILS commands
fabriclog Displays or manipulates the fabric log
fabricname Configure fabric name
fabricprincipal Configure Principal Switch Selection mode
fabricshow Print fabric membership info
fabstatsshow Displays the fabric statistics information
fabswitchshow Display fabric switch state information
fandisable Disables a fan unit.
fanenable Enables a fan unit.
fanshow Print fan status
fapwwn Configure the Virtual PWWN for port
fastboot Reboot this switch and bypass POST
fciphelp Print FCIP help info
fcipledtest Cycle user port LEDs.
fcippathtest Data Path Test of the FCIP complex.
fcoe Displays and configures FCoE ports FIP and fcmap
configurations
fcoelogincfg Enable/Disable Save or display FCoE login
configuration
fcoelogingroup Creates or modifies FCoE login configuration
fcping Sends a FC ELS ECHO request to a port
fcplogclear Clear the FCP log
fcplogdisable Disable logging of FCP events
fcplogenable Enable logging of FCP events
fcplogshow Display FCP probing log information
fcpprobeshow Display FCP probing information
fcprlsprobe Manage RLS probing
fcrbcastconfig Configure interfabric broadcast frame forwarding
fcrconfigure Sets FC Router configuration parameters.
fcredgeshow Displays FIDs assigned to defined EX_Port
fcrfabricshow Displays FC Routers on a backbone fabric.
fcriclpathbwmonitor Manage FC Router ISL bandwidth configuration
parameters
fcrlsan Configure LSAN policies
fcrlsancount Display maximum LSAN zone limit.
fcrlsanmatrix Manage LSAN fabric matrix configuration.
fcrphydevshow Displays FC Router physical device information.
fcrproxyconfig Displays or configures proxy devices presented by
an FC Router.
fcrproxydevshow Displays FC Router proxy device information.
fcrresourceshow Displays FC Router physical resource usage.
fcrrouterportcost Modify FC Router port cost configuration.
fcrrouteshow Displays FC Router route information.
fcrxlateconfig Displays or persistently configures a translate
(xlate) domain's domain ID for both
EX_Port-attached fabric and backbone fabric.
fctraceroute Displays FC traceroute information
fddcfg fddcfg manages the fabric data distribution
configuration parameters.
fdmicacheshow Display abbreviated remote FDMI device information
according to remote domain ID
fdmishow Display detailed FDMI device information
ficoncfg Manage FICON configuration
ficonclear Clears contents of the specified FICON management
database
ficoncupset Sets FICON-CUP parameters for a switch
ficoncupshow Displays FICON-CUP parameters for a switch
ficonhelp Displays FICON commands
ficonshow Displays contents of the specified FICON management
database
fipscfg Configure FIPS mode operation
firmwareactivate Activate firmware on secondary partition
firmwarecheck Verify firmware signature
firmwarecleaninstall Perform from scratch firmware install
firmwarecommit Commit firmware to stable storage
firmwaredownload Download firmware into switch
firmwaredownloadstatus Display the progress and status of firmwareDownload
firmwarekeyshow Manage the keys used to check firmware signatures
firmwarerestore Restore the old firmware in the switch
firmwareshow Display firmware versions in the switch
firmwaresync Perform firmware synchronization
flow Configure Flow Vision services
fosconfig Enable/disable FabOS services
fosexec Invoke command in remote domain
framelog Configure logging of discarded frames
framerpathtest Tests data path between ASICs
fruinfoset sets data in FRU Header
fspfshow Print FSPF global information
geporterrshow Print GigE port error summary
grep Linux grep command
h Print shell history
hadisable Disables the High Availability feature in the
switch.
hadump Displays information about the status of the High
Availability feature in the switch.
haenable Enables the High Availability feature in the switch
hafailover Forces the failover mechanism so that the Standby
Control Processor (CP)becomes the Active CP.
haredundancy Displays HA redundancy status
hashow Displays control processor (CP) status
hasyncstart Enables HA state synchronization.
hasyncstop Disables the HA state synchronization.
help Print this list
historyclear Clears the Field Replaceable Unit (FRU) history log
historylastshow Displays last history record
historymode Display or set the mode of the history log
historyshow Displays entire history log
i Display process summary
iclcfg Configure ICL state
iflshow Display edge switch FCR connection information
ifmodeset Set the link operating mode for a network interface
ifmodeshow Display the link operating mode for a network
interface
interfaceshow Display the FSPF (TM) interface information
iodreset Turn off the in-order delivery (IOD) option
iodset Manage the in-order delivery (IOD) option
iodshow Display the state of the in-order delivery option
ipaddrset Set ethernet and FC IP addresses
ipaddrshow Print ethernet and FC IP addresses
ipfilter Manage/display IP filters
ipsecconfig Configure IPSec feature
islshow Display the current connections and status
killtelnet Terminate telnet/serial login sessions
interactively
ldapcfg Configure LDAP role mapping
lfcfg Configure logical fabrics
licenseadd Adds license keys to switch
licenseidshow Displays the system license ID
licenseport Configure per-port POD license assignments
licenseremove Removes a license key from this system
licenseshow Displays current license keys
licenseslotcfg Configure licenses on a slot basis
linkcost Set or print the FSPF cost of a link
logicalgroup Manage MAPS logical groups
login Login as a new user
logout Logout from remote session
lscfg Configure logical switches
lsdbshow Displays the FSPF link state database
mapsconfig Configure MAPS global parameters
mapsdb Display MAPS dashboard summary
mapshelp Display all MAPS commands
mapspolicy Configure MAPS policies
mapsrule Configure MAPS threshold monitoring rules
mapssam Display system availability monitor information
memshow Display memory usage in the system.
minispropshow Displays ASIC pair properties.
more Linux more command
motd Set chassis login banner
mscapabilityshow Display Management Server Capability.
msconfigure Configure Management Server
msfr Create a MSFR Zone
msplatshow Display the Management Server Platform Database
msplatshowdbcb Display the Management Server Database Control
Block
msplcleardb Clear the Management Server Platform Database
fabric-wide
msplmgmtactivate Activate the Management Server Platform Database
fabric-wide
msplmgmtdeactivate Deactivate the Management Server Platform Database
fabric-wide
mstddisable Disables the Management Server Topology Discovery
Management Service
mstdenable Enables the Management Server Topology Discovery
Management Service
mstdreadconfig Display status of Management Server Topology
Discovery Service
myid Display the current login session details
nbrstateshow Display FSPF (TM) neighbors' states
nbrstatsclear Reset the FSPF (TM) interface counters
netstat Display network connections and statistics
nodefind Display all the devices' PID matching the given
world wide name
nsaliasshow Display local Name Server information with Aliases
nsallshow Print global Name Server information
nscamshow Print local Name Server Cache information
nsdevlog Manage Name Server device logs
nsshow Print local Name Server information information
nszonemember Display the information of all the online devices
which are zoned with the given device.
nszoneshow Display zone names of specific zoned devices
openfr Create a MSFR Zone
opensource Display information on open source software
utilized in FabOS
passwd Set usernames and passwords
passwdcfg passwdcfg manages the password policies.
pathbwconfig Manage ISL and ICL bandwidth features
pathinfo Display routing information between two ports
pdshow Show information from Panic Dump file
ping Display the link operating mode for a network
interface
ping6 Display the link operating mode for a network
interface
portaddress Configure low 16 bits of Fibre Channel Porrt ID
portalpashow Show the ALPAs of a port
portbeacon Enable or disable port beacon
portbuffercalc Compute port buffer requirements
portbuffershow Print the buffer allocations for the ports of a
quad
portcamshow Display filter utilization
portcfg Create/Delete a new ip interface/route/arp entry on
the GigE port
portcfgalpa Set AL_PA to 0x0 (default) or 0x13
portcfgautodisable Configure auto disable
portcfgcompress Configure in-flight data compression
portcfgcreditrecovery Configure credit recovery
portcfgdefault Restore the port configuration to defaults
portcfgdport Configure Diagnostic port function
portcfgencrypt Configure in-flight data encryption
portcfgeport Enable/Disable a port from becoming E_Port
portcfgeportcredits Configure credits for E_Ports
portcfgexport Sets a port to be an EX_Port and sets and displays
EX_Port configuration parameters.
portcfgfaultdelay Configure fault delay for a port
portcfgfec Configure Forward Error Correction feature
portcfgfillword Configure a port to a particular fill word
portcfgflogilogout Configure port FLOGI logout option
portcfgfportbuffers Configure F_Port buffers
portcfgge Configure GigE port features
portcfggemediatype Configure media type for GigE port
portcfggport Lock a port as a G_Port
portcfgislmode Configure a port to be ISL R_RDY Mode
enabled/disabled
portcfglag Configure GigE port static lag
portcfglongdistance Configure a Long Distance Port
portcfglosstov Configure frontend port signal debounce
portcfglport Lock a port as a L_Port
portcfgnondfe Configure Decision Feedback Equalization feature
portcfgnpivport Configure NPIV functionality on a port.
portcfgnport Enable/disable N_Port capability for a port
portcfgoctetspeedcombo Set port speed combination for port octet
portcfgpersistence Configure port persistence state
portcfgpersistentdisable Persistently disable a port
portcfgpersistentenable Enable a persistently disabled port
portcfgqos Configure QoS feature
portcfgshow Displays port configuration settings.
portcfgspeed Configure a port to a particular speed level
portcfgtdz Configure Target Driven Zoning for a port
portcfgtrunkport Configure a port for trunking
portcfgvexport Sets a port to be an VEX_Port connected to FC-IP
and sets and displays VEX_Port configuration
parameters.
portchannelshow Display port channels to remote domain(s)
portcmd Execute commands (ping etc) on the GigE port
portdebug Set debug level and verbosity level of port modules
portdecom Disable E_Port in trunk group
portdisable Disable a specified port
portdporttest Enable Diagnostic port test
portenable Enable a specified port
portenccompshow Print the encryption and compression configurations
for the ports of a chip present in the switch.
porterrshow Print port error summary
portflagsshow Display the port status bitmaps of all ports in a
switch
portledtest Cycle user port LEDs.
portlogclear Clear port activity log
portlogconfigshow Display portlog configuration
portlogdisable Disable portlog facility
portlogdump Print port log (no page breaks)
portlogdumpport Print port log (no page breaks)
portlogenable Enables port log facility
portlogeventshow Display information about port log events
portloginshow Display port login information
portlogpdisc Set or clear the debug_pdisc_flag
portlogreset Enable portlog facility
portlogresize Resize the port log
portlogshow Print port activity log
portlogshowport Print port activity log
portlogtypedisable Disable port logging
portlogtypeenable Enable port logging
portloopbacktest Functional test of port N->N path.
portmirror Manage port mirroring configuration
portname Assign or display the name associated with a port
portperfshow Print port throughput numbers
portpeerbeacon Enable or disable port peer beacon
portrouteshow Display various routing tables for a port
portshow Show configured ip interfaces/routes/arp entries on
the GigE Port
portstats64show Display the 64-bit hardware statistics for a port
portstatsclear Clear the status of a specified switch port
portstatsshow Print hardware statistics
portswap Swaps area numbers
portswapdisable Disable portswap feature
portswapenable Enable portswap feature
portswapshow Display port and area information
porttest Functional test on a live fabric. Starts porttest.
porttestshow Retreive information from porttest.
porttrunkarea Configure area trunking
portzoneshow Displays the enforced zone type of the F/FL-ports
of a switch.
powerofflistset sets slot power off list order
powerofflistshow Displays slot power-off order.
psshow Print power supply status
rasadmin Manage RAS log filters
rasman Display RAS message description
reboot Reboot this processor
relayconfig Configure email server address
roleconfig Manage user-defined RBAC roles
routehelp Print routing help info
rtlogtrace Configure logging facility for asynchronous dual CP
conditions
sddquarantine Manage MAPS quarantine state
secactivesize Displays size of the active (security) database
secauthsecret Creates/Manages DHCHAP secret key details
seccertutil Creates/Manages/Displays third party PKI
certificates
seccryptocfg Configures allowed ciphers
secdefinesize Displays size of the defined (security) database
secglobalshow Displays current internal security state
information
sechelp Displays information about security commands
secpolicyabort Aborts changes to defined policy
secpolicyactivate Activates all policy sets
secpolicyadd Adds members to an existing policy
secpolicycreate Creates a new policy
secpolicydelete Deletes an existing policy
secpolicydump Displays all members of existing policies
secpolicyfcsmove Moves a member in the FCS policy
secpolicyremove Removes members from an existing policy
secpolicysave Saves defined policy set and sends to all switches
secpolicyshow Shows members of one or more policies
secstatsreset Resets security statistics
secstatsshow Displays security statistics
sensorshow Display sensor readings
serdestunemode Configure serdes tuning mode
setcontext Select logical switch context
setdbg Set debug level of the specified module
setverbose Set verbosity level of the specified module
sfpshow Print Serial ID SFP information
shellflowcontroldisable Disable xon-xoff flow control on console serial
port
shellflowcontrolenable Enable xon-xoff flow control on console serial port
sleep Linux sleep command
slotpoweroff Removes power from a slot.
slotpoweron Restores power to a slot.
slotshow Displays the status of all slots in the system.
snmpconfig Configure SNMP
snmptraps Configure SNMP traps
spinfab Functional test of switch to switch ISL cabling and
trunk group operation.
sshutil Configure SSH authentication options
statsclear Clear port and diagnostic statistics.
stopporttest Terminate the running porttest.
supportffdc Modifies or displays first-failure data capture
(FFDC) configuration.
supportftp set support Ftp parameters
supportinfoclear Clear selected counters and logs in preparation for
supportsave operation
supportsave retrieve support data from switch to host
supportshow Prints switch information for debugging purposes.
supportshowcfgdisable Disables a group of commands under supportshow
command.
supportshowcfgenable Enables a group of commands under supportshow
command.
supportshowcfgshow Displays the groups of commands enabled for
display. by the supportshow command.
switchbeacon Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable Enable a persistently disabled switch
switchcfgspeed Configures all ports of the switch to a particular
speed level
switchcfgtrunk Configure all ports on the switch for trunking
switchdisable Disable this switch
switchenable Enable this switch
switchname Print/set this switch's name
switchshow Print switch and port status
switchuptime Display the amount of time for which the switch is
up
switchviolation Display policy violations recorded in RAS log
syslogadmin Configure the syslog facility
syslogdfacility Change the syslog facility
syslogdipadd Add syslog daemon IP address
syslogdipremove Remove syslog daemon IP address
syslogdipshow Print the syslog daemon targets
sysshutdown Provides a graceful shutdown to protect the switch
file systems.
systemverification Run a suit of diagnostic tests on all switches in a
system.
tempshow Print temperature readings
timeout Set/show the IDLE timeout value for a login session
top Linux top command
topologyshow Display the unicast fabric topology
tracedump generate/remove trace dump or display trace dump
status
trunkdebug Debug a trunk link failure
trunkshow Display trunking information
tsclockserver Displays or sets the NTP server address
tstimezone Displays or sets the time zone
turboramtest Turbo SRAM test for bloom ASICs.
uptime Print how long switch has been up
urouteshow Display unicast routing information
usbstorage Manage USB storage device (available on Brocade
Data Center Director only).
userconfig Display or configure user accounts
userrename Rename user login name
version Print firmware version
wwn Display or set the world wide name
wwnaddress Configure persistent PID assignments
zone Configure zone objects
zoneadd Add a member to a zone
zonecreate Create a zone
zonedelete Delete a zone
zonehelp Print zoning help info
zoneobjectcopy Copies a zone object
zoneobjectexpunge Expunges a zone object
zoneobjectrename Rename a zoning Object
zoneobjectreplace Replace a zoning Object
zoneremove Remove a member from a zone
zoneshow Print zone information
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Switch must be disabled to execute this command.
You must first disable the switch using "switchdisable" then try again.
DS_6510B_Secondary_2:root> switchdisable
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> configdefault
WARNING: This is a disruptive operation that requires a switch reboot.
Would you like to continue [Y/N]: y
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2016/10/10-12:23:59, [FCR-1069], 115, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is enabled.
2016/10/10-12:23:59, [FCR-1068], 116, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing service is disabled.
2016/10/10-12:23:59, [FCR-1070], 117, FID 128, INFO, DS_6510B_Secondary_2, The FC
Routing configuration is set to default.
Committing configuration ... done.
2016/10/10-12:24:00, [MAPS-1113], 118, FID 128, INFO, DS_6510B_Secondary_2, Policy
dflt_base_policy activated.
The switch has to be rebooted to allow the changes to take effect.
2016/10/10-12:24:00, [CONF-1031], 119, FID 128, INFO, DS_6510B_Secondary_2,
configDefault completed successfully for switch.
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> passwd admin
Changing password for admin
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Saving password to stable storage.
Password saved to stable storage successfully.
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:26:50 2016...

Security Policy, Password or Account Attribute Change: admin will be logged out
2016/10/10-12:26:51, [SEC-1197], 120, FID 128, INFO, DS_6510B_Secondary_2, Changed
account admin.
2016/10/10-12:26:53, [SEC-1193], 121, FID 128, INFO, DS_6510B_Secondary_2, Security
violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:26:55, [IPAD-1002], 122, FID 128, INFO, DS-6510B, Switch name has
been successfully changed to DS-6510B.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> 2016/10/10-12:28:52, [SEC-1193], 123, FID 128, INFO, DS-
6510B, Security violation: Login failure attempt via HTTP. IP Addr: 10.77.77.75.
2016/10/10-12:29:49, [HTTP-1002], 124, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:29:49, [ZONE-1010], 125, FID 128, WARNING, DS-6510B, Duplicate
entries in zone (zone_0_0) specification.
sw0 Updating flash ...
2016/10/10-12:29:49, [ZONE-1022], 126, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:29:49, [HTTP-1002], 127, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
2016/10/10-12:30:53, [HTTP-1002], 128, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.
sw0 Updating flash ...
2016/10/10-12:30:53, [ZONE-1022], 129, FID 128, INFO, DS-6510B, The effective
configuration has changed to cfg.
2016/10/10-12:30:53, [HTTP-1002], 130, FID 128, INFO, DS-6510B, Zoning transaction
initiated by User: admin, Role: admin completed successfully.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
Broadcast message from root Mon Oct 10 12:33:38 2016...

Security Policy, Password or Account Attribute Change: AdmUserREM will be logged


out
2016/10/10-12:33:39, [SEC-1181], 131, FID 128, INFO, DS-6510B, Deleted account
AdmUserREM.

Broadcast message from root Mon Oct 10 12:33:40 2016...

Security Policy, Password or Account Attribute Change: AdmUserHRV will be logged


out
2016/10/10-12:33:41, [SEC-1181], 132, FID 128, INFO, DS-6510B, Deleted account
AdmUserHRV.

DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> ^M
: command not found
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root>
DS_6510B_Secondary_2:root> sys
sysTraceShow syslogdFacility syslogdipshow
sysctl syslogdIpAdd sysshutdown
sysfpga_upgrade.sh syslogdIpRemove systemVerification
syslog-ng syslogdIpShow systemverification
syslogAdmin syslogdfacility systraceshow
syslogadmin syslogdipadd
syslogd syslogdipremove
DS_6510B_Secondary_2:root> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y

Broadcast message from root (ttyS0) Mon Oct 10 12:44:46 2016...

The system is going down for system halt NOW !!


INIT: Switching to runlevel: 0
INIT: Sending processes the TERM signal
DS_6510B_Secondary_2:root> ##RSCMON exiting due to signal: 19, pending signals:
0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
The system is halted
Shutdown: hda
Power down.

Power down.

You might also like