Professional Documents
Culture Documents
The Appropriate Tool Used in Cutting Flexible Armored Cable
The Appropriate Tool Used in Cutting Flexible Armored Cable
Choose the letter of the best answer and write the letter of your answer on the separate sheet of paper:
________8. It is any associated material for connecting end of stock securely.
a. Fitting c. Rigid
b. Ground d. Wire ways
________9. It is used for mounting a convenience outlet on walls.
a. Junction Box c. Utility Box
b. Frames d. Fitting
________10. It is used for splitting conductors and splices.
a. Utility Box c. Junction Box
b. Fastening Device d. Adhesive
________11. It is a bend used to adopt the conduit from the surface to a particular box or fittings.
a. Bending c. Conduit bending
b. Offset d. Strap
________12. It is a process of removing sharp edges or burrs left after cutting the pipe.
a. Shaping c. Finishing
b. Reaming d. Smoothing
________13. What is the tool used to bend a metallic conduit?
a. Hacksaw b. Hickey c. Hammer d. Reamer
________14. How many degrees is a quarter angle bend?
a. 45 degrees c. 180 degrees
b. 90 degrees d. 135 degrees
________15. What type of conduit is designed to lessen or eliminate fire hazard and electrical accident?
a. Electrical Metallic Tubing c. Polyvinyl Chloride
b. Rigid Steel Conduit d. Armored Cable (BX)
________16. How many quarter bends are allowed in a one run of electrical metallic and nonmetallic
conduit as allowed by the code?
a. 2 b.3 c. 4 d. 6
________17. What type of fitting is used to secure EMT to metallic boxes?
a. connector
b. condulets
c. adapter with locknut
d. coupling
________18. What is the type of bend that makes one quarter turn ?
a. offset b. elbow c. saddle d. goose neck
________19. What is the standard length of Rigid Metallic Conduit?
a. 10 ft. b. 12 ft. c. 14 ft. d. 20 ft.
________20. A neutral conductor shall be placed within the__________.
a. same conduit b. the other conduit
b. separate circuit d. anywhere
________21. _____14. It is the minimum size of conduit which can be installed
________22. in industrial occupancies.
a. b. 3 /4 c. 1 d. 1
________23. _____15. It is a type of fitting which is used to change direction.
a. connector b. coupling c. adaptor d. elbow
________24. _____16. It is a short length conduit or tubing which is used to
________25. extend a conduit system and used between conduit
________26. and tubing such as boxes or enclosures between two boxes.
a. connector b. coupling c. nipple d. condulets
________27. _____17. It is the type of bend which is used for circuit homerun.
a. offset b. elbow c. saddle d. goose neck
________28. _____18. What electrical materials are used for the installation of
________29. electrical wiring fixtures like switches, receptacles and for
________30. making electrical termination?
a. Utility Box b. Square Box
b. Junction Box d. Electrical Boxes
________31. ______19. What code is responsible for setting the rules and
________32. regulations which govern all electrical wiring installations
________33. wherein standard and specifications must be followed?
a. Municipal Code b. Local Code
b. Philippine Electrical Code d. National Electrical Code
________34. ______20. What types of electrical conduit are designed to protect the
________35. electrical wiring of building from electrical hazard due to
________36. faulty wiring?
a. Electrical Metallic Tubing b. Rigid Steel Conduit
b. Polyvinyl Chloride d. Flexible Metallic Tubing
________37. On your answer sheet, write the letter of your answer.
________38. Name the following Intermediate Metallic Conduit materials.