Structure weight calculation

Night shelter size 50' x 30' x 10'


Particular Length in meter Size in mm Thickness in mm Nos.
Column 3.05 100 x 100 4 8
Raf 6 65 x 65 3.5 8
Member 10 100 x 100 3.5 4
Purlin 6 50 x 50 2.5 42
Brecing 4 50 x 50 2.5 8
Head member for ridge 17 65 x 65 3 2
Eave strut 15.5 65 x 65 3 2
Foundation plate 0.2 200 x 200 5 24
Channel 50 0.132 2.5 2
Square pipe for in side joint truss to truss 9.5 65 x 65 3.5 6
cleat for raf to column 0.2 200 x 200 5 16
cleat for purlin 0.1 65 5 84
cleat for in side square 0.1 65 5 20
Foundation J nuts/bolt 0.4 dia 16 32

Total Weight
weight in kg.
306.464
342.888
439.600
989.100
125.600
208.182
189.813
37.680
259.050
407.180
25.120
255.125
51.025
16.000

3652.827
Structure weight calculation
Night shelter size 30' x 10' x 10'
Particular Length in mm Size in mm Thickness in mm Nos.
Column 3050 120 x 62 3.5 3
Column 2800 120 x 62 3.5 3
Raf 9150 100 x 50 3 2
Raf 3660 100 x 50 3 3
Purlin 9760 60 x 40 2.5 3
Eave strut 9760 60 x 40 2.5 2
Foundation plate 200 200 16 12
Foundation plate 200 200 12 12
cleat for raf to column 0.2 200 x 200 5 16
Channel 48800 132 2 1
Foundation J nuts/bolt 0.4 dia 16 24
weight in kg.
91.508
84.008
129.290
77.574
114.924
76.616
60.288
45.216
25.120
101.133
16.000
821.676